G-Brane P Series Membrane Module Specification

Drawing Spec.

80A Model G-Brane P5 G-Brane P7

Effective Area, m2(ft2) 50 (538.2) 75(807.3)

65A D1 216(8.50) 216(8.50)

D2 236(9.29) 236(9.29)
Dimension,
mm(in)
L1 1,303(51.30) 1,724(67.87)

L2 1,731(68.15) 2,152(84.72)
Module
Material PVDF, PVC, PU

pH 1 ~ 12

Membrane Type Pressurized Hollow Fiber Membrane

L1 L2 Pore Size 0.1㎛

Dry 32(70.5) 40(88.2)


Weight, kg(lb)
Wet 64(141.1) 80(176.4)

Operating Pressure TMP < 1.50 kgf/cm2 (22psi)


D1
Water treatment, Reuse,
Application
RO Pretreatment, etc.

Operation Temp., ℃(℉) < 40 (104)


D2
Flux, LMH(GFD) 40 ~ 85 (23.6~50.1)

Recovery > 90%

Chemical Cleaning ~ 5,000 mg/L as NaOCl


G-Brane S Series Membrane Module Specification

Drawing Spec.

D Model G-Brane S2 G-Brane S3 G-Brane S4

Effective Area, m2(ft2) 29(312.2) 35(376.7) 40(430.6)

D 234(9.21) 234(9.21) 234(9.21)

Dimension,
L1 1,291(50.83) 1,616(63.62) 1,902(74.88)
mm(in)

L2 1,653(65.08) 1,978(77.87) 2,264(89.13)

Module Material PVDF, PVC, PU

pH 1 ~ 12

Membrane Type Submerged Hollow Fiber Membrane


L1
Pore Size 0.1㎛
L2
Dry 13(28.7) 20(44.1) 22(48.5)
Weight, kg(lb)
Wet 15(33.1) 27(59.5) 30(66.1)

Operating Pressure TMP < 0.50 kgf/cm2 (7.1psi)

Temp. ℃(℉) < 40 (104)

Flux, LMH(GFD) ~ 30(17.7GFD)


Operation
Operating Cycle
Suction 9min, Backwash 1min
(Recommended cycle)

MLSS 6,000 ~ 8,000mg/L

Chemical Cleaning ~ 5,000 mg/L as NaOCl