Iogp S-563 Mds Id145
Iogp S-563 Mds Id145
Iogp S-563 Mds Id145
Qualification Manufacturers and the manufacturing process shall be qualified in accordance with ISO 17782 or
NORSOK M-650. The qualification testing shall meet the requirements of this MDS.
Heat treatment The plates shall be solution annealed followed by water/liquid quenching.
Plates shall be placed in such a way as to ensure free circulation of heating and cooling media around each
plate during the heat treatment process including quenching.
Tensile testing Tensile test specimens shall be sampled in the transverse orientation to the direction of final rolling.
Impact testing / The sampling of test specimens, testing methodology and acceptance criteria shall comply with
toughness testing ISO 17781 QL II.
Corrosion testing The sampling of test specimens, testing methodology and acceptance criteria shall be in accordance with
ISO 17781.
Micrographic The sampling of test specimens, testing methodology and acceptance criteria for microstructural examination
examination including ferrite measurements shall be in accordance with ISO 17781.
Extent of testing One tensile, one set of impact tests, one corrosion test and one micrographic examination including ferrite
measurement shall be carried out for each heat of steel and heat treatment lot.
Sour service When sour service requirements are specified by the purchaser, the material shall conform to the
(additional requirements of ISO 15156/NACE MR0175 or ISO 17945/NACE MR0103, and the following additional
metallurgical, requirements to the MDS.
manufacturing,
testing and Hardness testing
certification Production testing shall be performed in accordance with the requirements in ASTM A370/A1058 on one plate
requirements) a per lot. For coil, tests shall be carried out at both ends of the coil. The maximum hardness shall be 28HRC
from three readings taken in close proximity at each location.
The material shall be traceable in accordance with ISO 15156-3/NACE MR0175-3, section 7.2 and this MDS.
Marking The plates, sheets or strips shall be marked to ensure full traceability to heat and heat treatment lot.