Frnfcon-Structural Design 1 (Reinforced Concrete)
Frnfcon-Structural Design 1 (Reinforced Concrete)
Frnfcon-Structural Design 1 (Reinforced Concrete)
Group members:
Barroga, Mark Kevin B
De Luna, Kate Loren
Taberdo, Kent
Taruc, Jeri Casalinde
Activity 3
1. A rectangular beam has b = 300 mm, d = 500 mm, As = 3-25mm bars, fc’ = 34.2 MPa, fy = 414 MPa.
Calculate the design moment Mu. Use 2010 Code.
Computation:
π
AS = (25)2 x 3
4
AS = 1472.62156 mm2
AS
[𝜌 = ]
𝑏𝑑
0.05
𝛽1 = 0.85 − (34.2 − 30)
7
𝛽1 = 0.8164
0.85(34.2)(0.8164)(600)
𝜌𝑏 =
414(600+414)
0.009817(414)
𝜔=
34.2
𝜔 = 0.1188
𝑀𝑢 = 0.90(34.2)(0.1188)(300)(500)2 [1 − 0.59(0.1188)]
= 255,112,714.6847 𝑁 − 𝑚𝑚
𝑴𝒖 = 𝟐𝟓𝟓. 𝟏𝟏𝟑 𝒌𝑵 − 𝒎
2. A rectangular beam reinforced for tension only has b = 300 mm, d = 490 mm. The tension steel area
provided is 7-25mm diameter bars with fy = 415 MPa, fc’ = 21 MPa. Calculate the ultimate moment
capacity of the beam. Use 2010 Code.
Computation:
π
AS = (25)2 x 7
4
AS = 3436.116965 mm2
AS
[𝜌 = ]
𝑏𝑑
b=300 0.85
c=0.85 ab
a
490-a/2
=3436
-18:
T=
[C = T]
0.85𝑓′𝑐 𝑎𝑏 = 𝐴𝑆 𝑓𝑠
0.85(21)(0.85𝑐)(300) = 3436.116965𝑓𝑠
𝑓𝑠 = 1.324678𝑐
𝑓
0.003 0.003+ 𝑠⁄𝐸
𝑠
[ = ]
𝑐 𝑑
0.003 0.003+1.324678𝑐⁄200000
=
𝑐 490
0.003 600+1.324678𝑐
=
𝑐 98000000
[𝑀𝑢 = ∅𝑇(𝑑 − 𝑎⁄
2)]
= ∅𝐴𝑠 𝑓𝑠 (𝑑 − 𝑎⁄2)
1
𝑀𝑢 = 0.90(3436.116965)(392.42722)[490 − 251.80688⁄2] ×
10002
𝑴𝒖 = 𝟒𝟒𝟏. 𝟖𝟔𝟏 𝒌𝑵 − 𝒎