COMPLETE ONE-CHIP METER REFERENCE DESIGN SUPPORT ECOSYSTEM

Member of DLMS User Association since 2010 Hardware


Member of The Standard Transfer Specification
Association (STS) since 2016

DLMS Application, COSEM, Library

Renesas Training
& Consultancy Testing
(Device and
Software System)
REA REE
RECN
Third Party REIN RETW
-Support PC GUI for Meter Tuning,
RESG Device (SFR), Signal Evaluation, Meter Log
-Turn Key Solutions
Meter Application, Metrology and Drivers

Documentation

Auto Tuning Tools

Tools

Easy, Available, Highly Competitive Ecosystem for Metering


© 2019 Renesas Electronics Corporation. All rights reserved.
10
EMBEDDED METERING PLATFORM STRUCTURE

Application
DLMS Stack Power Mgmt Load Swt. Ctrl. Display Calibration Startup

User
COMM Setup FOTA Event & Schedule Button & LED Data Storage OA / ICT
Anti Tamper

Event Callback
Anti-Temper Plug-in
Plug-in

EM Core Lib
Middleware
Common API EM Core API
Conversion Measurement Multi-Tariff
Mathematical HW SW Shared Manual Calibration

Wrapper
MW
UART IIC CONFIG PULSE ADC TIMER WDT RTC

SCI CRC LVD GPIO MACL 1HzRTC SAU

Generated
Drivers
RTC BUP UART DSAD INTP SAFETY

CG
TMR
WDT CGC LCD KEY ADC TEMP SENSOR

Hardware

© 2019 Renesas Electronics Corporation. All rights reserved.


DLMS SERVER SOFTWARE OVERVIEW
Meter Application

COSEM Object Layer


Prepayment
Class 1 Class 3 Class 4 Class 15 Others… class

COSEM Application Layer


AES GCM
COSEM Event Image Security
Open
GET SET Action
Notification Transfer
Push
Plug-In Library

APDU
Connection
Manager
HDLC RENESAS
DLMS Library

RENESAS Mode E Physical Layer COMM Wrapper Layer


Code Generator
SPI / SPI /
UART Port 1 UART Port 2
UART Port 3 UART Port 4

© 2019 Renesas Electronics Corporation. All rights reserved. 20


STS LIBRARY OVERVIEW – FOR PRE-PAYMENT METERS
Register Setting Credit Management System

Register clear Credit Decoder Key


Transfer Change
Set Register
limits Set TariffRate
Meter Test/
Display
RENESAS STS Library
Tamper reset Clear Credit TID Rollover
Decoding Class 0 [Credit Transfer]

Decoding Class 1 [Self Test/Display]


MAP (meter app process) Layer
Decoding Class 2 [Register Setting]

APP (application) Layer Encryption / Decryption

PHY (physical) Layer Decoder key Generation

Numeric Optical COMM TID Calculation


NFC Card
Keypad Reader Module

© 2019 Renesas Electronics Corporation. All rights reserved.


WHAT IS Wi-SUN?
“Wireless - Smart Ubiquitous [ formerly Utility ] Network”
is an open standards-based robust, secure, and
interoperable IoT communications for large-scale utility,
industrial, and home networks.

▪ Renesas is a founding member of the Wi-SUN Alliance


▪ Wi-SUN Alliance specifies wireless communications networks
based on IEEE 802.15.4g RF (and derivatives) and IPv6/6LowPAN
for Field Area Networks (FAN) and Home Area Networks (HAN)
▪ Defines testing and certification program for multi-vendor
interoperability
▪ Over 180 members in North America, Europe, India, Japan,
Singapore -- including product vendors, semiconductor …
manufacturers, software companies, utilities, government
institutions, and universities.

© 2019 Renesas Electronics Corporation. All rights reserved.


Wi-SUN FAN
OVERVIEW

▪ Wi-SUN FAN (Field Area Network) is a wireless communications specification for:


▪ Large networks of smart edge/node devices (smart meters, IEDs, RTUs, other complex
sensor-based devices…)
▪ Unlicensed 863~928MHz ISM RF spectrum
▪ Supporting frequency-hopping, mesh networking, security, and full IPv6 routing (Layer 3)
Border Router

Router
PAN1 IPv6 Backbone (w/ CA)
Router
PAN3
PAN2

Router/Leaf Wi-SUN FAN


Router/Leaf networks

© 2019 Renesas Electronics Corporation. All rights reserved.


Wi-SUN FAN Stack : API Functions
Simple and easy to use
Category API Function
Initialization R_NWK_Init,
R_NWK_ResetRequest
Network management R_NWK_StartRequest
R_NWK_JoinRequest
UDP R_UDP_DataRequest
R_UDP_RegisterRequest
R_UDP_UnRegisterRequest
ICMP R_ICMP_EchoRequest
PIB control R_NWK_GetRequest
R_NWK_SetRequest
Power management R_NWK_Suspend
R_NWK_Resume

© 2019 Renesas Electronics Corporation. All rights reserved.


DISTANCE TEST 1/2
P2P field test result on a long straight line of good prospect in Japan.

Reached 1.6km at 100kbps (PER<1%)


We measured the communication distance on a long line of sight straight line. At this time, both the
transmitter and the receiver are fixed with a tripod at a height of 2m from the ground.
When 1,000 packets were transmitted, we measured the packet error rate.
Up to 1600m, PER<1% result was obtained.

30 0
PER
25 -20
RSSI
20 -40

RSSI - dBm
PER - %
15 -60
0km
2km
10 -80

5 -100
measurement environment
0 -120
Google 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
<Measurement condition> Distance - m
CH=926.7MHz, Output Power=+13dBm(20mW)
Data Rate=100kbps, Modulation=2GFSK, Modulation Index=1 Packet error rate in each measurement
Preamble=8byte, FCS=4byte, Payload=20byte, FEC disabled
point
© 2019 Renesas Electronics Corporation. All rights reserved. BIG IDEAS FOR EVERY SPACE
DISTANCE TEST 2/2
P2P field test result under heavy traffic conditions in India

Reached 430m at 50kbps (PER<1%)


In India, we measured the communication distance across a road with heavy traffic.
As a result, we confirmed PER<1% up to 430m at 50kbps.
Distance vs RSSI
Signal Condition -50
RF module
CH :866.9MHz Receiver RSSI
Reader-Reader
Power :+15dBm -60 PER<1%
(Receiver) Rate :50kbps(m=0.5) Limit
Preamble :8byte
Data :20byte -70
Interval :5ms

RSSI (dBm)
-80

-90
Receive
-100

-110 This line shows PER is OK. (PER<1%)


Send The limit is 430m (PER<1%)
-120
0 50 100 150 200 250 300 350 400 450 500
RF module (Transmitter) Distance (m)

© 2019 Renesas Electronics Corporation. All rights reserved. BIG IDEAS FOR EVERY SPACE
Field Test Result- 22dBm module Singapore test site : Communicating from 8th floor

External Anenna : Monopole Wire Antenna (86 mm Length)


Part No Anaren A1101R08C
FAR FIELD MEASUREMENTS (TRUE NON-LINE OF SIGHT)
PtP Range
POWER POWER RSSI RSSI LQI LQI LQI
ANT LOC (Meteres) Column1 RSSI MIN BER
Setting (dBm) MAX AVG MIN MAX AVG
Approximate
INT L1 100 OR 25 15 -90 -86 -87 36 52 44 0.00%
INT L1 100 OR 30 16 -84 -83 -83 60 64 60 0.00%
INT L1 100 OR 50 20 -82 -80 -80 68 76 73 0.00%
INT L1 100 OT 25 15 -104 -87 -95 0 48 14 0.00%
INT L1 100 OT 30 16 -87 -84 -85 48 60 53 0.00%
INT L1 100 OT 50 20 -99 -86 -89 36 52 0 0.00%
EXT L1 100 OR 25 15 -89 -86 -99 36 52 0 0.00%
EXT L1 100 OR 30 16 -98 -97 -99 1 8 0 0.00%
EXT L1 100 OR 50 20 -96 -95 -101 9 16 0 0.00%
EXT L1 100 OT 25 15 -99 -99 -101 0 0 0 0.00%
EXT L1 100 OT 30 16 -100 -97 -103 1 8 0 3.04%
EXT L1 100 OT 50 20 -100 -98 -104 0 4 0 1.29%
EXT L2 80 OR 50 20 -99 -93 -101 0 16 0 0.11%
EXT L3 150 OR 50 20 -97 -95 -102 7 16 0 0.00%
EXT L4 200 OR 50 20 -102 -100 -107 0 0 0 0.00% L4
EXT L4 200 OT 50 20 -101 -99 -105 0 0 0 0.42%
INT L4 200 OT 50 20 -100 -95 -110 0 16 0 0.02%
INT L4 200 OR 50 20 -99 -99 -101 0 0 0 0.00%
INT L5 200 OR 50 20 -98 -86 -108 6 52 0 0.07%
L3
INT L5 200 OT 50 20 -87 -85 -92 45 56 28 0.00%
EXT L5 200 OR 50 20 -107 -104 -113 0 0 0 0.06%
EXT L5 200 OT 50 20 -103 -103 -104 0 0 0 11.40%
L5

L2

L1

DUT – 8th Floor


GU – Ground Level
© 2019 Renesas Electronics Corporation. All rights reserved.