Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Semi Converter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

MODELLING AND SIMULATION OF SINGLE PHASE SEMI CONTROLLED

BRIDGE RECTIFIER WITH R AND RL LOADS.


EX.NO: DATE:
Aim:
To model and simulate the single phase semi controlled bridge rectifier with R and RL loads
by using MATLAB/SIMULINK.
Requirements:
Procedure:
Steps to create modeling by using MATLAB/SIMULINK:

Components Tool Box / Block parameters


Library browser

AC Voltage Simpower Systems / AC voltage Peak Amplitude(v) =230*sqrt(2)


Source Electrical sources source Phase(deg) =0
Frequency(Hz) =50
Thyristors Simpower Systems / Thyristor
(T1 &T2) Power Electronics Default

Diodes Simpower Systems / Diodes Default


(D1 & D2) Power Electronics

Repeating Simulink / Sources Repeating Time Values = [0 0.01 0.01 0.02]


Sequence(R1) Sequence Output Values = [0 5 0 0]
Repeating Simulink / Sources Repeating Time Values = [0 0.01 0.02 0.02]
Sequence(R2) Sequence Output Values = [0 0 5 0]
Relational Simulink /Math Relational Greater than or equal to (>=)
Operator Operations Operator
(2 numbers)
Constant Simulink / Sources Constant Constant Value=1

Fourier Simpower Fourier Fundamental Freq : 50


Systems/Extra Harmonic: 0
Library/Measurements
Load Simpower Systems / Series RLC Resistance(Ohm) =10
Elements Branch Inductance(H) =8e-03
Capacitance(F) =inf

1. Click on File NewModel.


2. On resulting window click on library Browser, a Simulink library browser will appear.
3. Make/Model the circuit by placing all its Blocks from its corresponding Library/toolbox,
which is clearly shown in the table 1. Right click on the block to rotate mirror etc. to
organize the circuit elements.
4. To get any one of the element in series RLC branch, such as R, L, or C, click on series
RLC branch block in the Simpower System/Element library, and enter the parameters
value in such a way that other two elements are invisible. That is to eliminate resistance,
inductance, or capacitance of the branch, the R, L and C values must be set respectively
to 0, 0 and inf.
5. To change the circuit parameters applicable to the block by double clicking on the
block/element and type the values. Keep the values default for some blocks like thyristor,
diodes, mosfet etc.
6. To measure/observe the voltage across or current passes through the electrical
block/device, connect voltage measurement or current measurement blocks
respectively with the electrical block, it is available on the library Simpower
System/measurement.
7. To observe the waveform in figure window, scope block is connected with voltage
measurement and current measurement blocks. This scope block is available by click on
Library browsersimulink/sourcescope.
8. For single phase semi controlled Bridge rectifier with RL load, components required
and its parameter values are similar to that of RLE load, except E parameter. That is DC
voltage source block must remove from schematic. The schematic arrangement is shown
in schematic diagram 2.
9. For single phase semi controlled Bridge rectifier with R load, components required
and its parameter values are similar to that of RLE load, except L and E parameters. That
is L must set to 0, and DC voltage source is removed from the schematic. The schematic
arrangement is shown in schematic diagram 1.
10. Before simulating the circuit, ensure that all the blocks are connected properly. The most
common error encountered is ‘floating node’. This usually means that there is some
problem in interconnects.
Steps to simulating the circuit by using MATLAB/SIMULINK:
1. After correcting all floating node errors start by creating a simulation.
2. Click on simulationconfiguration parameters and make sure that solver option is
‘ode15s’, it is essential when circuit contains power system or power electronics tools.
And the stop time value should be 5/50 for 50Hz supply frequency for five cycles. For
‘n’ number of cycles, stop time would be n*(1/50) for 50Hz supply, where n=1, 2, 3….
and also set Max Step Size to 1e-5 and Min Step Size to 1e-6
3. To run the simulation, select simulation start.
4. If any errors are reported here. Correct schematic or the simulation settings and re-run
simulation.
5. To view simulation plots on simulation window, double click the scope in the schematic.
The scope block corresponding to voltage measurement and current measurement blocks
gives voltage and current waveforms respectively with respect to time.
Formulas Used:
Vc
Firing Angle α = * 180
VT
Where Vc= Value of Constant Block in the Simulation
VT = 5
Vm
Average Load Voltage (Edc) = (1 + cos α )
π
Where Vm= 230* 2
TABLE 1: For R Load
Slno Control Voltage Firing Angle ( α ) Simulated Edc Calculated Edc
1
2
3
4
5

TABLE 2: For RL Load


Slno Control Voltage Firing Angle ( α ) Simulated Edc Calculated Edc
1
2
3
4
5

Result:
The model of single phase semi wave controlled bridge rectifier with R, RL, and RLE load is
created and simulated by using MATLAB/SIMULINK and the corresponding waveforms are
observed.
SCHEMATIC DIAGRAM: 1
SINGLE PHASE HALF CONTROLLED BRIDGE RECTIFIER WITH R LOAD

WAVEFORMS FOR R-LAOD: (R =10)


SCHEMATIC DIAGRAM: 2

SINGLE PHASE HALF CONTROLLED BRIDGE RECTIFIER WITH RL LOAD

WAVEFORMS FOR CONTINUOUS MODE FOR RL LOAD: (L=8mh, R=10)

You might also like