Power Electronics Lab Assignment-XI: Simulation of Full Bridge Inverter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Power Electronics Lab Assignment-XI

SIMULATION OF FULL BRIDGE INVERTER.

OBJECTIVE:

Simulation and Analysis of Full Bridge Inverter.

COMPONENTS REQUIRED:

MATLAB Simulink.

THEORY:

A single phase bridge DC-AC inverter is shown in figure.11.1. When the switches S1 and
S2 are turned on simultaneously for a duration 0 ≤ t ≤ T1, the input voltage Vs appears
across the load and the current flows from point ‘a’ to point ‘b’.

S1 and S2 (ON), S3 and S4 (OFF) ==> Vo = Vs

If the switches S3 and S4 turned on during T1 ≤ t ≤ T2, the voltage across the load is
reversed and the current through the load flows from point ‘b’ to point ‘a’.

S1 and S2 (OFF), S3 and S4 (ON) ==> Vo = -Vs

CIRCUIT DIAGRAM:

Fig: 11.1: Full-bridge inverter Circuit.


Power Electronics Lab Assignment-XI

SETTING UP SIMULATION:

1) Run MATLAB software by double click on desktop icon.


2) Open blank untitled Simulink model window for creating a new model.
3) Drag and drop required blocks from Simulink library Browser window.
4) Make the circuit as shown in circuit diagram.
1 180
5) Set phase delay in pulse generator 0 for switch S1, S2 and (𝑓) ∗ (360) for S3 & S4.
6) Run the simulation and plot different graphs for analysis.

REQUIRED BLOCKS AND THEIR LOCATION IN SIMULINK LIBRARY:

S.NO Block Name Block set location in the


Simulink library browser
1 DC Voltage Source Simpower/Electrical Sources
2 Diode Simpower/Power Electronics

3 MOSFET/ IGBT Simpower/Power Electronics

4 R/C/L Simpower/Elements
5 Powergui Simpower
6 Voltage Simpower/Measurement
Measurement
7 Scope and Display Simulink/Sink
8 Pulse Generator Simulink/Sources
Table.11.1: Required Blocks and Their Location in Simulink Library.
Power Electronics Lab Assignment-XI
SIMULINK MODEL:

Vs=100V, R=100Ω, L=500mH.

FIGURE 1 SIMULATION OF FULL BRIDGE INVERTER R LOAD

FIGURE 2 SIMULATION OF FULL BRIDGE INVERTER RL LOAD


Power Electronics Lab Assignment-XI

SCOPE OUTPUT:

FIGURE 3 FULL BRIDGE INVERTER R LOAD (d=50%)

FIGURE 4 FULL BRIDGE INVERTER RL LOAD (d=50%)


Power Electronics Lab Assignment-XI

FIGURE 5 FULL BRIDGE INVERTER RL LOAD (d=50%)

FIGURE 6 FULL BRIDGE INVERTER RL LOAD (d=50%)

Student Task:

1. Draw the waveforms of output voltage, current through each switch and output current with
R and RL load for a specific duty cycle.

NOTE: Follow the “PE_LAB_REPORT_TEMPLATE” uploaded in Class Team.

You might also like