Product data sheet CA3KN22FD

Characteristics TeSys K control relay - 2 NO + 2 NC - <= 690 V -


110 V DC standard coil

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range TeSys
Product name TeSys CAK
Product or component type Control relay
Device short name CA3K
Contactor application Control circuit
Utilisation category AC-15
DC-13
Pole contact composition 2 NO + 2 NC
[Ue] rated operational voltage <= 690 V <= 400 Hz
Control circuit type DC standard
[Uc] control circuit voltage 110 V DC

Complementary
[Ith] conventional free air thermal 10 A at <= 50 °C
current
Irms rated making capacity 110 A conforming to IEC 60947
Associated fuse rating 10 A gG conforming to IEC 60947
10 A gG conforming to VDE 0660
[Ui] rated insulation voltage 600 V conforming to CSA C22.2 No 14
690 V conforming to BS 5424
690 V conforming to IEC 60947
750 V conforming to VDE 0110 group C
Mounting support Plate
Rail
Connections - terminals Screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid
Screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid
Screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 1 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 2 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - without cable end
Tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 6 mm

Mar 7, 2019
1
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit voltage limits 0.8...1.15 Uc at 50 °C operational
0.1...0.75 Uc at 50 °C drop-out
Operating time 10 ms coil de-energisation and NO opening
15 ms coil de-energisation and NC closing
25...35 ms coil energisation and NC opening
30...40 ms coil energisation and NO closing
Mechanical durability 20 Mcycles
Operating rate 10000 cyc/h
Immunity to microbreaks 2 ms
Inrush power in W 3 W at 20 °C
Hold-in power consumption in W 3 W at 20 °C
Heat dissipation 3W
Minimum switching voltage 17 V
Minimum switching current 5 mA
Non overlap distance 0.5 mm
Insulation resistance > 10 MOhm
Height 58 mm
Width 45 mm
Depth 57 mm
Product weight 0.225 kg

Environment
Standards BS 5424
IEC 60947
VDE 0660
NF C 63-140
Product certifications CSA
UL
IP degree of protection IP2x
Protective treatment TC conforming to IEC 60068
Ambient air temperature for operation -25...50 °C
Ambient air temperature for storage -50...80 °C
Operating altitude 2000 m without derating in temperature
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustness Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations contactor open 2 Gn, 5...300 Hz IEC 60068-2-6
Shocks contactor open 10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed 15 Gn for 11 ms IEC 60068-2-27

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant  - since  0640  -  Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Available
End of Life Information

Contractual warranty
Warranty period 18 months

You might also like