MC Q
MC Q
MC Q
A Long distance
B Short distance
C Parallel
D All of above
Hide Answer
Answer A
A Series
B Asynchronous
C Parallel
D Synchronous
Hide Answer
Answer c
A Series
B Asynchronous
C Parallel
D synchronous
Hide Answer
Answer c
Question The 8051 has two pins for transferring and receiving data by serial
communication. These two pins are part of the ____________
A Port 0
B Port 1
C Port 2
C Port 2
D Port 3
Hide Answer
Answer D
A PCON
B TMOD
C TCON
D SCON
Hide Answer
Answer D
A TCON
B PCON
C SCON
D IP
Hide Answer
Answer B
Hide Answer
Answer A
Question To double the Baud rate set by the SCON Register________.
A SM0
B SM1
C SM2
D REN
Hide Answer
Answer C
Question ______ behaves as shift Register with fixed Baud rate in serial
communication.
A MODE 3
B MODE 2
C MODE 1
D MODE 0
Hide Answer
Answer D
A TF0 ,TF1
B INT0, INT1
C RI, TI
D None of the above
Hide Answer
Answer C
A TRUE
B FALSE
C May have or may not have
D None of the above
Hide Answer
Answer A
Question What voltage levels are used for binary 0 in communication standard RS
232?
A 0 Volt
B +5 Volt
C -3 to -25 Volt
D +3 to +25 Volt
Hide Answer
Answer D
Question What voltage levels are used for binary1 in communication standard RS
232?
A 0 Volt
B +5 Volt
C -3 to -25 Volt
D +3 to +25 Volt
Hide Answer
Answer C
Question RS 232 is not TTL compatible, to make it TTL compatible _____ must be
used.
Question ______ is used to set different Baud rates to transfer and receive data
serially.
A counter0
A counter0
B TMOD
C TCON
D Timer 1
Hide Answer
Answer D
Question In serial communication to set the Baud rate in Timer1, frequency
is_______.
A Serial Mode 3
B Serial Mode 0
C Serial Mode 2
D Serial Mode 1
Hide Answer
Answer D
Question In serial Mode 1 for each character a total of _______ bits are transferred.
A 8
B 16
C 10
D 11
Hide Answer
Answer C
A SBUF
B SCON
C TCON
D PCON
Hide Answer
Answer A
Question To transfer and receive data , the status of REN bit in SCON Register must
be
A REN= 1
B REN= 0
C REN= tri-stated
D None of the above
Hide Answer
Answer A
Question In Serial communication when 8051 finish data transfer it raises ______ to
indicate that it is ready to transfer another byte.
A TI Flag
B CY Flag
C RI Flag
D OV Flag
Hide Answer
Answer A
Question In serial communication to indicate that Data Byte is received in SCON
Register___
A 11
B 8
B 8
C 16
D 10
Hide Answer
Answer A
Question To double the Baud Rate; ______ bit of PCON register is used in serial
communication.
A GF1
B SMOD
C GF0
D PD
Hide Answer
Answer B
A 0
B 1
C Undefined
D None of these
Hide Answer
Answer A
Question In serial communication, SMOD bit of PCON register should be ______ to
double the Baud rate.
A 0
B 1
C Undefined
D None of these
Hide Answer
Answer A
Question In parallel data transfer ____ data lines are needed to transfer data.
A 16
B 11
C 13
D 8
Hide Answer
Answer B
A Simplex
B Duplex
C Half Duplex
D Full Duplex
Hide Answer
Answer A
Question ________ is a character oriented data transfer in which one data byte is
transfer serially at a time.
Question In ____ two separate clock input can be used for Transmission and Receiver.
A TB8
B RB8
C REN
D SM2
Hide Answer
Answer C
A TB8
B RB8
C SM2
D REN
Hide Answer
Answer D
Question In MODE 1 of serial communication after receiving data byte, start bit is
discarded 8 bit data goes to SBUF while stop bit is saved into __________of
SCON Register.
A REN
B SM2
C TB8
D RB8
Hide Answer
Answer D
Hide Answer
Answer A
Hide Answer
Answer B
Show Answer
Show Answer
Hide Answer
Answer D