Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MC Q

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

(/Main/) / Home (/Main/) /…

/ Fundamentals of Microcontroller and Applications (/Main/Savitribai-Phule-Pune-University/EE/FMA-SE/)

/ FMA Multiple Choice Questions Unitwise (/Main/Savitribai-Phule-Pune-University/EE/FMA-SE/MCQ/)


/ FMA Unit-4 MCQ's (/Main/Savitribai-Phule-Pune-University/EE/FMA-SE/MCQ/Unit-4/)

FMA Unit-4 MCQ's


Updated on 2018/02/23 19:32

FMA Unit-4 MCQ's PART-A (1 Mark Question)


Question    Serial communication is generally used for __________ communication.

A    Long distance
B    Short distance
C    Parallel
D    All of above
Hide Answer
Answer    A

Question    Speed of the ________ data transfer scheme is extremely high.

A    Series
B    Asynchronous
C    Parallel
D    Synchronous
 
Hide Answer
Answer    c

Question    Which of the following type of communication is very expensive?

A    Series
B    Asynchronous
C    Parallel
D    synchronous
 
Hide Answer
Answer    c

Question    The 8051 has two pins for transferring and receiving data by serial
    communication. These two pins are part of the ____________

A    Port 0
B    Port 1
C    Port 2
C    Port 2
D    Port 3
 
Hide Answer
Answer    D

Question    Serial communication is controlled by _________ register.

A    PCON
B    TMOD
C    TCON
D    SCON
 
Hide Answer
Answer    D

Question    The Acronym UART stands for_______

A    Universal ASCII Receiver Transmitter


B    Unified Asynchronous Receiver Transmitter
C    Universal Asynchronous Receiver Transmitter
D    Universal Asynchronous Receive and Transmit
 
Hide Answer
Answer    C

Question    Identify the byte addressable register out of the following.

A    TCON
B    PCON
C    SCON
D    IP
 
Hide Answer
Answer    B

Question The unit of Baud Rate is

A    Bits per second


B    Baud per second
C    Bytes per second
D    Data per second

Hide Answer
Answer    A

Question    To double the Baud rate set by the SCON Register________.

A    The bit TCON.7 should be set


B    The bit PCON.7 should be set
C    The bit SCON.7 should be set
D    Baud rate cannot be doubled
 
Hide Answer
Answer    B

Question    In MODE 0 of serial communication, baud Rate is equal to______

A    1/12 Oscillator frequency


B    Oscillator frequency
C    1/16 Oscillator frequency
D    1/32 Oscillator frequency
 
Hide Answer
Answer    B

Question    ________ bit in SCON register is set for multiprocessor communication.

A    SM0
B    SM1
C    SM2
D    REN
 
Hide Answer
Answer    C

Question    ______ behaves as shift Register with fixed Baud rate in serial
    communication.

A    MODE 3
B    MODE 2
C    MODE 1
D    MODE 0
 
Hide Answer
Answer    D

Question    For Serial Communication an interrupt in 8051 is______.

A    TF0 ,TF1
B    INT0, INT1
C    RI, TI
D    None of the above
 
Hide Answer
Answer    C

Question    What is the role played by Timer 1 in serial communication?

A    It creates Time delay


B    Has no role in serial communication
C    It is used as Counter
D    To generate baud Rate
D    To generate baud Rate
 
Hide Answer
Answer    D

Question 8051 has built in UART.

A    TRUE
B    FALSE
C    May have or may not have
D    None of the above

Hide Answer
Answer    A

Question    What voltage levels are used for binary 0 in communication standard RS
    232?

A    0 Volt
B    +5 Volt
C    -3 to -25 Volt
D    +3 to +25 Volt
 
Hide Answer
Answer    D

Question    What voltage levels are used for binary1 in communication standard RS
    232?

A    0 Volt
B    +5 Volt
C    -3 to -25 Volt
D    +3 to +25 Volt
 
Hide Answer
Answer    C

Question    RS 232 is not TTL compatible, to make it TTL compatible _____ must be
    used.

A    Analog to Digital Converter


B    Line Driver ( Voltage Converter)
C    Latch
D    Digital to Analog Converter
 
Hide Answer
Answer    B

Question    ______ is used to set different Baud rates to transfer and receive data
    serially.

A    counter0
A    counter0
B    TMOD
C    TCON
D    Timer 1
 
Hide Answer
Answer    D

Question    In serial communication to set the Baud rate in Timer1, frequency
    is_______.

A    Oscillator frequency / 12/ 8 UART


B    Oscillator frequency / 12/ 16 UART
C    Oscillator frequency / 12/ 10 UART
D    Oscillator frequency / 12/ 32 UART
 
Hide Answer
Answer    D

Question    __________  allows variable Baud Rate.

A    Serial Mode 3
B    Serial Mode 0
C    Serial Mode 2
D    Serial Mode 1
 
Hide Answer
Answer    D

Question    In serial Mode 1 for each character a total of _______ bits are transferred.

A    8
B    16
C    10
D    11
 
Hide Answer
Answer    C

Question    In serial communication _________ Register is used to hold Data.

A    SBUF
B    SCON
C    TCON
D    PCON
 
Hide Answer
Answer    A
Question    To transfer and receive data , the status of REN bit in SCON Register must
    be

A    REN= 1
B    REN= 0
C    REN= tri-stated
D    None of the above
 
Hide Answer
Answer    A

Question    If the status of REN bit in SCON Register is 0, then

A    Data can be transmitted serially


B    Receiver is disabled
C    No serial data communication is possible
D    None of the above
 
Hide Answer
Answer    B

Question    In Serial communication when 8051 finish data transfer it raises ______ to
    indicate that it is ready to transfer another byte.

A    TI Flag
B    CY Flag
C    RI Flag
D    OV Flag
 
Hide Answer
Answer    A

Question    In serial communication to indicate that Data Byte is received in SCON
    Register___

A    TI Flag is raised


B    CY Flag is raised
C    RI Flag is raised
D    OV Flag is raised
 
Hide Answer
Answer    C

Question    In multiprocessor mode (serial Mode 2) of serial communication; data is


    transmitted as _________ bits.

A    11
B    8
B    8
C    16
D    10
 
Hide Answer
Answer    A

Question    To double the Baud Rate; ______ bit of PCON register is used in serial
    communication.

A    GF1
B    SMOD
C    GF0
D    PD
 
Hide Answer
Answer    B

Question    When powered up, SMOD bit of PCON register is ______

A    0
B    1
C    Undefined
D    None of these
 
Hide Answer
Answer    A

Question    In serial communication, SMOD bit of PCON register should be ______ to
    double the Baud rate.

A    0
B    1
C    Undefined
D    None of these
 
Hide Answer
Answer    A

Question    In parallel data transfer ____ data lines are needed to transfer data.

A    16
B    11
C    13
D    8
 
Hide Answer
Answer    B

Question    ________ transmission is one way transmission.


Question    ________ transmission is one way transmission.

A    Simplex
B    Duplex
C    Half Duplex
D    Full Duplex
 
Hide Answer
Answer    A

Question    ________ is a character oriented data transfer in which one data byte is
    transfer serially at a time.

A    Asynchronous data transfer


B    Bulk data transfer
C    Byte Data Transfer
D    Synchronous data transfer
 
Hide Answer
Answer    A

Question    In ____ two separate clock input can be used for Transmission and Receiver.

A    Bulk data transfer


B    Byte Data Transfer
C    Synchronous data transfer
D    Asynchronous Data transfer
 
Hide Answer
Answer    D

FMA Unit-4 MCQ's PART-B ( 2 Marks Questions)


Question    The _________ allows baud rate to be variable and is set by _______ of
    8051.

A    Serial Mode 0, Timer 1


B    Serial Mode 1, Timer 1
C    Serial Mode 2, Timer 0
D    Serial Mode 3, Timer 1
 
Hide Answer
Answer    B

Question    MOV SCON,#50H will select __________

A    Serial Mode 3 , REN enabled


B    Serial Mode 1, REN enabled
C    Serial Mode 2, REN enabled
D    Serial Mode 0, REN enabled
 
 
Hide Answer
Answer    B

Question    SETB SCON.4 will set ________ bit in SCON Register.

A    TB8
B    RB8
C    REN
D    SM2
 
Hide Answer
Answer    C

Question    CLR SCON.4 will reset ________ bit in SCON Register.

A    TB8
B    RB8
C    SM2
D    REN
 
Hide Answer
Answer   D

Question    In MODE 1 of serial communication after receiving data byte, start bit is
    discarded 8 bit data goes to SBUF while stop bit is saved into __________of
    SCON Register.

A    REN
B    SM2
C    TB8
D    RB8
 
Hide Answer
Answer    D

Question    Serial communication is _____ while parallel communication is ______

A    Half Duplex, Full Duplex


B    Full Duplex , Half Duplex
C    Full Duplex , Duplex
D    None of these
 
Hide Answer
Answer    B

Question    To maintain data integrity _________ is/are checked.

A    Only start bit


B    Only stop bit
C    Only parity bit
C    Only parity bit
D    Start, stop, parity bit
 
Hide Answer
Answer    D

Question Serial Mode 0 is _______

A    Synchronous and half duplex


B    Synchronous and full duplex
C    Asynchronous and half duplex
D    Asynchronous and full duplex

Hide Answer
Answer    A

Question Serial Mode 1 is _______

A    Asynchronous and half duplex


B    Asynchronous and full duplex
C    Synchronous and half duplex
D    Synchronous and full duplex

Hide Answer
Answer    B

Question Serial Mode 2 is _______

A    Asynchronous and half duplex


B    Asynchronous and full duplex
C    Synchronous and half duplex
D    Synchronous and full duplex

Show Answer

Show Answer

Question Serial Mode 3 is _______

A    Synchronous and half duplex


B    Synchronous and full duplex
C    Asynchronous and half duplex
D    Asynchronous and full duplex

Hide Answer
Answer    D

References
WikiNote Foundation 
Questions by Prof Omkar Shete, Electrical Dept., Sinhgad's NBNSIT, Pune
 

Tags:
Created by Sujit Wagh (/XWiki/sujitwagh) on 2018/01/28 18:30

No comments for this page

You might also like