Type 2 Surge Arrester - VAL-MS 230/3+1 FM - 2838199: Key Commercial Data
Type 2 Surge Arrester - VAL-MS 230/3+1 FM - 2838199: Key Commercial Data
Type 2 Surge Arrester - VAL-MS 230/3+1 FM - 2838199: Key Commercial Data
com/sg/products/2838199
Surge voltage arrester consisting of base element with remote indicator contact and ground connectors, for
mounting on NS 35/7.5, nominal voltage: 230 V AC, 3 + 1 circuit
Key Commercial Data
Packing unit 1 pc
GTIN
Technical data
Dimensions
Height 99 mm
Width 71 mm
Depth 58 mm
Horizontal pitch 4 Div.
Ambient conditions
Degree of protection IP20 (only when all terminal points are used)
Ambient temperature (operation) -40 °C ... 80 °C
29-09-2015 Page 1 / 7
https://www.phoenixcontact.com/sg/products/2838199
General
Standards/specifications IEC 61643-11 2011
EN 61643-11 2012
IEC test classification II
T2
EN type T2
IEC power supply system TN-S
TT
Number of ports One
SPD design Combination type
Mode of protection L-N
L-PE
N-PE
Mounting type DIN rail: 35 mm
Color black
Housing material PA 6.6
PBT
Pollution degree 2
Flammability rating according to UL 94 V-0
Type DIN rail module, two-section, divisible
Number of positions 4
Surge protection fault message Optical, remote indicator contact
Protective circuit
Nominal voltage UN 240/415 V AC (TN-S)
240/415 V AC (TT)
Nominal frequency fN 50 Hz (60 Hz)
Maximum continuous operating voltage UC (L-N) 275 V AC
Maximum continuous voltage UC (N-PE) 260 V AC
Rated load current IL 80 A
Residual current IPE ≤ 5 µA
Standby power consumption PC ≤ 360 mVA
Nominal discharge current In (8/20) µs (L-N) 20 kA
Nominal discharge current In (8/20) µs (L-PE) 20 kA
Nominal discharge current In (8/20) µs (N-PE) 20 kA
29-09-2015 Page 2 / 7
https://www.phoenixcontact.com/sg/products/2838199
Indicator/remote signaling
Connection name Remote fault indicator contact
Switching function PDT contact
Operating voltage 5 V AC ... 250 V AC
125 V AC (UL)
30 V DC
Operating current 5 mA AC ... 0.75 A AC
1 A AC (UL)
1 A DC
Connection method Screw connection
Screw thread M2
29-09-2015 Page 3 / 7
https://www.phoenixcontact.com/sg/products/2838199
Connection data
Connection method Screw connection
Conductor cross section flexible min. 1.5 mm²
Conductor cross section flexible max. 25 mm²
Conductor cross section solid min. 1.5 mm²
Conductor cross section solid max. 35 mm²
AWG conductor cross section 15 ... 2
10 ... 2 (UL)
Screw thread M5
Tightening torque 4.5 Nm
30 lbf-in. (UL)
Stripping length 16 mm
UL specifications
UL class Type 4 SPD for Type 2 applications
Maximum continuous operating voltage MCOV (L-N) 275 V AC
Maximum continuous operating voltage MCOV (N-G) 260 V AC
Nom. voltage 230/400 V AC
Mode of protection L-L
L-N
L-G
N-G
Power distribution system 3Y
Nominal frequency 50/60 Hz
Voltage protection rating VPR (L-L) 1.8 kV
Voltage protection rating VPR (L-N) 1 kV
Voltage protection rating VPR (L-G) 1.5 kV
Voltage protection rating VPR (N-G) 0.9 kV
Nominal discharge current In (L-L) 20 kA
Nominal discharge current In (L-N) 20 kA
Nominal discharge current In (L-G) 20 kA
29-09-2015 Page 4 / 7
https://www.phoenixcontact.com/sg/products/2838199
Classifications
eCl@ss
ETIM
UNSPSC
Approvals
Approvals
Approvals
IECEE CB Scheme / UL Recognized / KEMA-KEUR / ÖVE / cUL Recognized / GL / CCA / EAC / EAC / CSA / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
29-09-2015 Page 5 / 7
https://www.phoenixcontact.com/sg/products/2838199
IECEE CB Scheme
UL Recognized
KEMA-KEUR
ÖVE
cUL Recognized
GL
CCA
EAC
EAC
CSA
cULus Recognized
Drawings
29-09-2015 Page 6 / 7
https://www.phoenixcontact.com/sg/products/2838199
51,5
L1 L2 L3 N
Application drawing
29-09-2015 Page 7 / 7