Fan Catalogue
Fan Catalogue
Fan Catalogue
AVC
Company profile
Total Thermal Solution Provider
Information
1.Company Profile: AVC 4
1.1. Research and Development 5
1.2. Factory Operation & Process Control 7
1.3. Quality and Six Sigma 8
1.4. Fan Tray Technology 9
DC axial fans
2.2. Types of Fans 15
2.3. Fan Selection & Installation 16
2.4. Options for Customisation 18
2.5. Definitions 19
2.6. Catalog Guidance 20
2.7. Type code & Glossary 21
2.8. Optional Fan Features 22
3. DC Axial Fans 24
3.1. Axial Fans for DC Operations 25
3.2. DC Axial Fans List 28 106
DC blower fans
4. DC Blower Fans 107
4.1. Blower Fans for DC Operations 108
4.2. Blower DC Axial Fans List 109 118
Asia Vital Components Co., LTD (Taiwan listed company AVC Global Support
since 2002: TSE: 3017) is the leading Total Thermal Solution AVC has 14 branch offices and 48 global logistic hubs in the
Provider in the world. AVC was established in 1991 with world. Our worldwide network of sales and FAE teams are
headquarter in Taiwan. Its revenue in 2011 was $800 million available for customers in Asia, North America, South America,
US dollars with over 12,000 employees and over 600 RD and Europe.
China. AVC also has the worldwide FAE and hub supports
Continuous Improvement.
AVC Products AVC New Chengdu Factory Will Mass Production On 2012 Q4.
Company profile
Total Thermal Solution Development Process Control and DFM
Information
AVC provides customers with comprehensive total thermal AVC drives straight product development process control
solutions by carrying out co-design with customers. AVC is using in-house developed PDP (Product Development
also capable of providing thermal simulation and in-house Procedure) system. AVC can monitor the schedule of the
integration capability. product development and can achieve DFM (Design for
DC axial fans
Extensive R&D Commitment
AVC products are full of innovation. Integrate engineering
Thermal Design
AVC uses CFDESIGN, ICEPak, Flotherm, EFD, PRO/E, Solid
Works, AutoCAD, and Heat Exchanger Design programs to
conduct thermal design and simulation.
Company profile
Enterprise Resource Planning System (ERP) Supplier Chain Management System (SCM)
Information
AVC has built up a customized ERP System to ensure on- AVC Supplier Chain Management is driven through in-
time delivery and shipment traceability to customers. house developed Supplier Service Network (SSN) platform.
By collecting customers' forecasts and purchase orders, AVC and suppliers exchange all EC, engineer drawings,
AVC can harmonize the internal resources and processes GP requirements, part approvals, production schedules,
to achieve effective production and logistics control. In material requests, supplier delivery commitments, P/O
addition, combined with ten years of hub management releases, vendor hub information and etc through SSN.
experience, AVC can provide Hub Delivery Management by
customers' requirement.
DC axial fans
Continuous Production Improvement
AVC focuses on Design for Manufac turing (DFM) in
Manufacturing Management System (MMS) design stage. During mass production, the continuous
AVC's in -house MMS also helps to manage f ac tor y improvement in Yield Rate, Cycle Time and Productivity are
operation and production process. Manufacturing Data achieved through Automation, Tooling, Fixture design, and
Analysis System (MDAS) is used to monitor daily cycle in-house Vertical Integration.
time, yield rate and productivity for each production line.
Shop Flow Control System is tracking all the material, work
DC blower fans
order and shipment status. Tooling Control System is used
to monitor tooling usage and life status while Equipment
Maintenance System is monitoring the maintenance
status of all manufacturing devices and equipments. As
human resource is also a key to the operation and overall
quality, Employee Capability Certified System can keep
the historical information of training and certification of all
employees.
AC fans
Quality Assurance System mandatory statistical quality control trainings. During the
AV C e n s u r e s t h e d e s i g n , t h e s e r v i c e s , a n d t h e product development phase, the CTQ (critical to quality)
manufacturing process quality via the well-functioned parameters are identified. The Stability and Capability
Quality Assurance System in every aspect. Our systems are of these parameters are monitored using SPC and CPK
certified by many standards including ISO9001, ISO14001, analysis. AVC continuously drives proactive quality control
OHSAS18001, S8000, ANSI/ESD S20.20, QC080000, TS-16949, by reducing the variation of critical parameters in the
and etc. manufacturing process control, rather than only inspection
to screen out bad products.
Company profile
Fan Trays:
Features:
AVC is one of the professional Fan Tray designers and
Wide Input range 19VDC 75VDC
Information
manufacturers, the products of which are widely used in
Low Voltage Shutdown and Startup
various industries such as Power System, Telecom Equipment,
Includes soft start and current limiting at start up
and Server etc...
Accepts and diode ORs dual power feeds
AVC offers normal Fan Tray Assembly including 1x2, 2x3 or 3x3
Over voltage and over current protection
model, which provides fast and high-efficient cooling ability
Reverse polarity protection
and is easy for installation and operation.
Hot-Swap Inrush current protection
The Fan Tray is possession of extensive function and setting
Programmable control mode options
up interface for users to complete programmable regulation
Function fail alarm Indication
of voltage, current, power and rotation speed according to
Thermal detect and fan speed control
customer s requirements.
PWM or voltage control speed
In additional, our Expert Team can develop the specific Isolated control inputs or outputs
program to optimize the operational interface.
DC axial fans
Redundant power feeds
AVC uses different communication protocols like I2C, RS232, Communication function: I2C/RS232/RS485...etc
and RS485 etc... To allow remote access data and electronic Custom design is accepted (ODM & OEM Design)
label upload and download.
We continuously optimize products in the early design stage
through system analysis, simulation, verification and integrated
production knowledge and proficient technique to reach
different customers requirements.
DC blower fans
Applications:
Electronics Cooling
Power Supplies
Telecommunications Equipment
Server Equipment
Ventilation system
AC fans
Control Functions:
10
Company profile
Technologies and Capabilities 12
Types of Fans 15
Fan Selection & Installation 16
Options for Customisation 18
Definitions 19
Catalog Guidance 20
Type code & Glossary 21
Optional Fan Features 22
Information
DC axial fans
DC blower fans
AC fans
11
With the advance of modern technology, it may not be analytical design software is first used to produce a basic
a surprise to observe that there is an apparent trend of aerodynamic design, before it is further optimised by
packing more performance into a smaller footprint in using Computational Fluid Dynamics (CFD) analyses and
all products across the industries. At the same time, this experiments. Commercial CFD packages are available to
has a side effect of increasing power density within the carry out computer simulations at standalone fan as well as
products, and led to an increasing demand for fan cooling system level. CFD offers a cost effective way to calculate the
capacity and efficiency. There is a constant pressure of flow field inside and around the fan. It is particular useful
delivering fans with higher performance and efficiency to when used to evaluate interactions between components
ensure the components run at their most optimum and and its effect in a thermal system.
provide undisturbed operation. With more than 300 highly
skilled engineers in multiple disciplines, AVC is perfectly
positioned to meet this challenge.
1.2. Aerodynamics ‒ elegance at work appropriate facility are essential to analyse and optimise
Aerodynamic design has a direc t impac t on fan acoustics in a scientific way. Fan acoustic measurements
per formance in terms of f low volume and pressure are taken in a specialised semi-anechoic chamber, where
delivery. It is so subtle that any small aerodynamic design the roof and walls are covered with sound absorbing
detail change could have a significant influence in the fan material. AVC in-house test facility has background noise
output. At AVC, fan aerodynamics is designed, tested and level sufficiently low enough. measure any quiet devices of
optimised using a combination of analytical, computational interest.
and empirical approaches. In-house developed Traditionally, sound pressure is the parameter used by fan
12
Company profile
Information
industry to compare fan noise . However, sound pressure fan operation as well as not affecting other components in
gives little information about how human ears truly react user systems. This is an application specific problem, and
to sound and this parameter has become increasingly our engineers are fully equipped and experienced to work
inadequate for the thermal management market. The with our customers for EMC optimised solutions.
extensive facility at AVC provides much more information
than just sound pressure measurement. 1.5. Bearing Systems ‒ dependable workhorse
■ Binaur al re cordin g usin g dummy h ead an d th e There are two types of bearing system used in AVC fan
subsequent advanced analyses are capable to provide products: ball bearing and advanced hydraulic bearing.
more insight about the sound quality.
■ Multiple microphones arranged in hemispherical array Ball Bearing
DC axial fans
are used to measure sound power from a device. Ball bearings are normally installed in pair and spring
These acoustic data forms the valuable resources when loaded in the axial direction. Ball bearing is the traditional
optimizing fan acoustics. choice for high performance fans that require long life
expectancy. Metallic balls are sandwiched between two
races with side plates in place to prevent lubricant leakage
and protect it from the environment.
13
1.6. Fan Construction ‒ stand up against the evaluate the life expectancy. A fan is classified as failure if
extremes any one of its key performance parameters, for example fan
Most of AVC fans are made from glass-fibre reinforced speed and sound pressure, is out of specification.
plastic. The plastic used has fire retardant added and is UL
94V-0 approved. Plastic is light, cost effective, and suitable 1.9. Rapid Prototyping ‒ shortened development
for mass production. Moreover, plastic parts can be easily time
made into complicated 3D shapes, which is useful for AVC is well aware that fast turn around time is critical to the
parts such as impeller to produce the best aerodynamic success of our client development programs. Our R&D team
performance. The housing of larger fans may be made from has in-house facility and workshop to produce prototypes
Aluminium, and for the very large radial fans (310+cm), the quickly for customers. This helps to resolve problems early
impellers are also made from aluminium. in the development and, more importantly, reduces the
number of iterations and development time.
1.8. Life and Reliability ‒ robust design initiative, striving for products that have the minimum
The quality and reliability of AVC fan products are tested by impact on the environment. All AVC fan products conform
carrying a number of tests such as high/low temperature to the European directive on the restriction of the use
running, thermal/mechanical shock, thermal cycling and of hazardous substances in electrical and electronic
vibration. Facilities for further testing such as water and equipments (ROHS). 100% Halogen free products are also
corrosion resistance are available at requested. available at request.
14
Company profile
Information
2.1. Axial Fan DF fan series ‒ Multiple rotating impellers and
Axial fans are suitable for applications where large flow motor drives in series
volume at medium system back pressure is required. High performance fans designed to produce very high
The exit flow field is close to parallel to the fan rotating static pressure in a small form-factor.
axis.
DC axial fans
DV fan series ‒ Overlapping impeller
Fans designed to work in systems with large impedance (air
flow resistance).
DC blower fans
2.2. Radial Fans
Radial fans are good for applications with high back
pressure and low f low volume. Flow is turned 90℃
inside the fan. Radial fan can be used with or without an
enclosure. The enclosure is used to enhance air pressure
and control exit flow direction. Large radial fans (120+
cm) are typically supplied without the enclosure and
appropriate inlet arrangement is recommended at
15
Using the concept of conversation of energy, the transport If the system impedance characteristics discussed in Step 2
of heat to moving air is given by is not available, it is recommended to select a fan with the
maximum flow delivery 20 to 30% higher than the cooling
H =m
Cp△T
Where
H = overall heat dissipation, W
m = mass flow of the moving air, kg/s
Cp = air specific heat capacity, J/kg.K (for dry air at 20℃, Cp≈1000J/kg.K)
△T = cooling air temperature rise between inlet and
exhaust, K
16
Company profile
Information
Fans can be installed either at the inlet side or the outlet 4.2. Advantages of installing fan at the exhaust
side of a passive thermal component or a thermal system. side
Under ideal conditions, the overall air delivery follows ■ Reduce the influence of low velocity, re-circulating zone
the system characteristic curve and there is no difference immediately downstream of fan.
where the fan is installed. However, in practice, there are ■ Better air flow control by careful selection of inlet
and user can decide what is best for their application. ■ Lower fan acoustics as exhaust openings are typically
4.1. Advantages of installing fans at the inlet ■ In general, distance of at least one fan depth should
DC axial fans
side be allowed between fan and its adjacent components to
■ Improve overall cooling capacity due to unsteady flow minimise interference and undesirable losses.
■ Longer fan life because of the lower inlet air Installing fan at system exhaust side H o t w o r k in g a ir
temperature.
InstallingF a fan
n at Installing
system exhaust
fan at side
system inlet
H o t w side
o r k in g a ir
DC blower fans
U n w a n te d le a k a g e flo w F a n
Mo r e u n i f o r m
c o o lin g flo w
Tu r b u l e n t f l o U w n w f o a r n b t e e d t t e l e r a c k o a o g l e i n fg l o w F a n
AC fans
17
AVC of fers a wide range of options to enhance the 5.4. Environmental Protection
func tionalit y of standard produc ts in order to fulfil A large number of our fans have been shipped to work
specialised requirements for different applications. Our in extreme operating environments that include dusty
experienced engineers are ready to discuss and assist you condition, high temperature, high humidity, and corrosive
to find the best solution for your application. environment. Although a complete design change may
not be necessary, additional treatments on bearing, motor
5.1. Input Voltage and electronic components may be required to ensure
Recommended input voltage range is specified for each fan undisturbed fan operation under these conditions. The
model in this catalogue. Fan electronics can be customised treatment can be a fully encapsulated stator/electronic
should your application requires the fan to operate under a assembly or a conformal coating over the electronic
wider input voltage range. components.
Control interfaces
Voltage and PWM signals are the most common type
of connection to control fan speed. PWM signal control
circuit can be implemented easily in system and this form
of control signal has become the main choice of control
interface in the industry.
Temperature control
For acoustic orientated applications, it may be ideal to
have a fan that has self adjusting speed function according
to temperature measurement from an onboard NTC
thermistor or an external signal. This allows the fans to
run at the lowest speed setting according to the local
cooling demand and results lower noise level and power
consumption during system operation.
Tacho Signal
If constant monitoring of fan speed is required, built in
sensor can be requested to output electronic signal for
system use.
18
Company profile
Information
6. Performance Measurements
6.1. Air Flow Measurements Maximum air pressure
Fan aerodynamic performance is tested in one of our in- Fan static pressure measured at zero air flow delivery. [Unit:
house wind tunnels which are capable of measuring air mm and inch height of water head, mmH20 and inch H20]
flow up to 3000cfm. The test facility and analysis used
follow the industry standard, AMCA 210-99. Test fans are Acoustic Noise
installed at the upstream side of the wind-tunnel with A-weighed sound pressure level measured one meter
free-air inlet and outlet (AMCA 210-99, installation type A). from fan inlet at rated voltage and free-air delivery in an
The PQ curves shown in this catalogue were measured at anechoic chamber. [Unit: dB(A)]
nominal input voltage.
Bearing Type
6.2. Acoustics Measurements Bearing system available for selection.
Acoustic measurements are taken in an anechoic chamber B ‒ 2 Ball Bearings
in accordance to ISO 7779, 3744 and 3745. For the sound R ‒ Advanced hydraulic bearing
DC axial fans
pressure level presented in this catalogue, microphone is
positioned one meter from fan inlet at free-air delivery. Fan air performance curve
The air performance curves were measured in accordance
7. Part No. with AMCA 210-99, test details are discussed in more detail
AVC part number for ordering. above, under the heading Air Flow Measurement .
DC blower fans
Pressure
Operating Voltage Range
1 mmH20 = 9.81Pa
The recommended operating input voltage range. [Unit:
1 inchH20 = 249Pa
Volt, V]
Rated current
Fan electric current at rated voltage and free-air delivery.
[Unit: Ampere, A]
Speed
Nominal fan speed measured at rated voltage and free-air
delivery. [Unit: revolution per minute, RPM]
19
DC AXIAL FANS
DV SERIES
80×80×38 mm 48v
DV SERIES
* Weight: 190g (6.1 OZ)
80×80×38 mm 48v
* Impeller: 5 Blades
Maximum Air Flow
Rated Input Power
Life expectancy
Rated Current
Bearing Type
MODEL
Operating Voltage Range
PART NO. SIGNAL B.T.S.R VDC VDC Amp Watt R.P.M. m3/min CFM mmH2O IN H2O dB-A hours
Maximum Air Flow
Rated Input Power
Acoustic Noise
Rated Voltage
Life expectancy
Rated Current
DV08038_48E -FG / RD B 48 43.2 to 52.8 0.09 4.32 5000 1.44 50.75 15.60 0.61 44.8 130000
Bearing Type
L10@40℃
Performance curves
Speed
DV08038_48L -FG / RD B 48 43.2 to 52.8 0.12 5.76 6000 1.74 61.61 21.65 0.85 49.4 130000
MODEL
T h e c h a r t i l l u s t r a te s t h e f a n DV08038_48M
PART NO. -FG / RD
SIGNAL B
B.T.S.R VDC 48
VDC 43.2
Ampto 52.8
Watt 0.18
R.P.M. m8.64
3/min 7000mmH2O 2.00
CFM IN H2O 70.70
dB-A 28.63
hours 1.13 53.2 130000
D e t a i l s o f t h e t e s t s e t- u p i s
DV08038_48U
DV08038_48M -FG
-FG / RD/ RD B B48 43.248
to 52.8 43.2
0.18to 52.8
8.64 0.33
7000 15.8
2.00 9000 28.63
70.70 2.631.13 92.92
53.2 44.53
130000 1.75 59.3 110000
DV08038_48H -FG / RD B 48 43.2 to 52.8 0.28 12.0 8000 2.34 82.62 36.39 1.43 57.2 110000
discussed in Section "Definitions". DV08038_48U -FG / RD B 48 43.2 to 52.8 0.33 15.8 9000 2.63 92.92 44.53 1.75 59.3 110000
Available Options
50.0
The icons indicate the optional
50.0
1.80 9000rpm
features available for the product,
1.80 45.0 9000rpm
45.0
1.60 ±0.3
40.0 38.0 4
8000rpm
38.0
±0.3 4
7000rpm
1.40
1.20
35.0
30.0
□ 71.5±0.3
AIR PRESSURE
7000rpm
10(REF.)
30.0
Ø89
310 ±10
0.80 20.0 .0
□ 71.5±0.3
5000rpm
10(REF.)
15.0
0.40 □7 Ø4.5
(MM-H2O)
(CFM)
AIR FLOW
20
Company profile
D A T A 07 20 B 2 U F A R
Information
Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ Ⅵ Ⅶ Ⅷ Ⅸ Ⅹ Ⅺ Ⅻ
DC axial fans
2 : ACFAN Circle ... Metal Impeller H : High Speed
3 : ACFAN Ellipse ... Metal Impeller
4 : ACFAN Square ... Metal Impeller Ⅸ CONTROL TYPE
5 : ACFAN Circle ... Plastic Impeller
― : General Control C : No Autorestart
6 : ACFAN Ellipse ... Plastic Impeller
D : Digital Control P : PWM Control
7 : ACFAN Square ... Plastic Impeller
S : Sensor Control V : Voltage Control
K : KH , S : SZ , D : Datech (* K . S . D For Old)
A : PWM + Sensor Control
Ⅹ SIGNAL OUTPUT
Ⅳ DIMENSION N : NA ( No Signal Output )
F : FG ( Frequency Generator or Tach Output )
03 : 3 cm 04 : 4 cm
R : RD ( Rotation Detector ) (* OEM 已用 S )
06 : 6 cm
DC blower fans
08 : 8 cm
V : ACFAN 外轉子內繞式 W : ACFAN 外轉子外繞式
13 : 13 cm 16 : 16 cm
X : ACFAN 內轉子內繞式 Y : ACFAN 內轉子外繞式
18 : 18 cm 22 : 22 cm etc …
Z : ACFAN AC轉DC
Ⅴ THICKNESS
07 : 7 mm 25 : 25 mm
Ⅺ SIGNAL OUTPUT VOLTAGE
10 : 10 mm 28 : 28 mm
A0 : 100 mm A1 : 101 mm A : Vcc ( Open Collector )
Ⅵ BEARING TYPE
Ⅻ OTHERS
A : One Ball Bearing
B : Two Ball Bearing FRAME TYPE (DC Axial)
C : Ceramic R : Rib Frame F : Flange Frame
G : Air Bearing ROTATING DIRECTION (DC Blower)
R : Hydraulic Bearing C : Clockwise D : Counterclockwise
S : Sleeve Bearing 出線方式 (ACFAN)
AC fans
21
The icons illustrated below are used in this catalogue to indicate the optional functions available for a particular fan.
These optional functions may not available in combination and at all voltages and speeds.
An additional wire is offered to output an The speed of the fan can be controlled via a
oscillating voltage output which can be used voltage signal carried by a dedicated input
by the system to infer the fan speed. wire.
An additional wire is offered to output a The elec tronics and motors of the fan
voltage signal when the fan is stationary. are protec ted against humidit y and
It is a useful functionality to identify non- condensation.
operating fan.
A NTC thermistor is integrated into the fan The electronics and motor are designed
design and the fan speed varies with the to offer protection against dust and water.
temperature measured by the thermistor. The digits behind the letters IP indicate
different levels of protection.
The speed of the fan can be controlled via a Salt fog test is used to simulate corrosive
pulse-width-modulated (PWM) signal carried environment that a fan may operate in. By
by a dedicated input wire. passing the test gives high confidence in the
robustness and reliability of the fan working
in extreme conditions.
22
Company profile
Axial Fans for DC Operations 24
Information
DC axial fans
DC blower fans
AC fans
23
Air Flow
Series
Page
0 10 20 30 40 50 60 70 80 90 100 200
mm CFM
□ 25 × 10 DASA2510 4.9 27
□ 30 × 07 DATA0307 1.9 28
□ 36 × 28 DB03628 19.8 29
□ 38 × 20 F3820 3.255 - 10.9 30
□ 38 × 28 DA3828 6.0 - 10.7 31
□ 38 × 28 DB03828 9.4 - 20.8 32
□ 38 × 28 DBTA0328 11.1 - 22.2 33
□ 40 × 10 DAKA0410 5.4 - 10.4 34
□ 40 × 10 DS04010 4.97 - 12.24 35
□ 40 × 20 DAKA0420 11.8 - 24.2 36
□ 40 × 20 DBTA0420 9.4 - 19.8 37
□ 40 × 20 DS04020 5.5 - 15.9 38
□ 40 × 28 DB04028 13.9 - 24.8 39
□ 40 × 28 DBTA0428 12.3 - 26.6 40
□ 40 × 28 DV04028 9.2 - 20.5 41
□ 40 × 56 DF04056 26.1 - 32.4 42
□ 40 × 56 DFTA0456 26.1 - 28.7 43
□ 50 × 10 DS05010 6.5 - 16.5 44
□ 50 × 15 DA05015 9.8 -17.5 45
□ 50 × 20 DS05020 9.3 - 21.4 46
□ 60 × 10 DA06010 13.5 - 25.3 47
□ 60 × 15 DA6015 14.6 - 26.7 48
□ 60 × 15 DA06015 14.7 - 28.5 49
□ 60 × 20 DS06020 10.8 - 39.3 50
□ 60 × 25 DAKA0625 20.8 - 53.2 51
□ 60 × 25 DS06025 10.9 - 38.9 52
□ 60 × 25 DATB0625 23.3 - 52.1 53
□ 60 × 25 DATB0625 23.3 - 52.1 54
□ 60 × 38 DS06038 19.5 - 39.5 55
□ 60 × 38 2B06038 45.8 - 72.4 56
□ 60 × 56 DFTA0656 60.1 - 84.9 57
□ 61 × 56 DFTA0676 75.5 - 84.9 58
□ 70 × 15 DA07015 29.4 - 45.0 59
□ 70 × 15 DS07015 22.0 - 44.0 60
□ 70 × 15 DE07015 26.5 - 38.8 61
□ 70 × 20 DA07020 38.2 - 54.3 62
□ 70 × 20 DV07020 23.8 - 46.2 63
□ 70 × 25 DY7025 50.4 - 52.3 64
□ 70 × 25 DS07025 26.8 - 64.6 65
□ 80 × 15 DS08015 23.9 - 49.35 66
□ 80 × 20 DA08020 34.1 - 61.8 67
□ 80 × 20 DS08020 36.0 - 59.8 68
□ 80 × 25 DBTA0825 49.3 - 63.9 69
□ 80 × 25 DL08025 23.7 - 54.5 70
□ 80 × 25 DS08025 29.3 - 64.4 71
□ 80 × 32 DASA0832 38.2 - 86.7 72
□ 80 × 38 DATA0838 79.4 - 95.7 73
□ 80 × 38 2B08038 55.8 - 129.5 74
□ 80 × 38 2B08038 55.8 - 129.5 75
□ 80 × 38 DYTB0838 115.2 76
□ 92 × 25 DAKA0925 42.5 - 106.6 77
□ 92 × 25 DL09225 37.9 - 70.8 78
□ 92 × 25 DS09225 32.7 - 79.5 79
□ 92 × 25 DYTB0925 73.7 80
□ 92 × 38 DCTA0938 89.8 - 129.6 81
24
Company profile
Overview Air Flow
Dimensions
Air Flow
Series
Page
10 50 80 90 100 200 300 400 500 600 800
mm CFM
Information
□ 120 × 25 DATA1225 58.5 - 138.2 86
□ 120 × 25 DBTA1225 130.0 - 140.8 87
□ 120 × 25 DBTA1225 130.0 - 160.7 88
□ 120 × 25 DS12025 67.7 - 121.1 89
□ 120 × 32 DA12032 56.4 - 133.6 90
□ 120 × 32 DATA1232 72.3- 163.7 91
□ 120 × 38 DAKA1238 88.8 - 207.4 92
□ 120 × 38 DATA1238 108.0 - 186.0 93
□ 120 × 38 DBTB1238 153.7 - 245.8 94
□ 120 × 38 2B12038 171.5 - 265.8 95
□ 127 × 38 DB12738 113.8 - 215.3 96
□ 127 × 38 DB12738 113.8 - 215.3 97
□ 130 × 38 DATA1338 120.1 - 212.6 98
□ 130 × 38 DATA1338 120.2 - 212.6 99
□ 150 × 25 DATA1525 151.8 - 263.2 100
□ 150 × 25 DATA1525 151.8 - 263.2 101
DC axial fans
Φ 150 × 51 DATA1551 259.5 - 393.7 102
Φ 150 × 51 DB15051 292.7 - 454.9 103
Φ 172 × 51 DA17251 257.7 - 392.5 104
Φ 200 × 70 DATA2070 250.0 - 559.5 105
gs
earin
earin
or
or
B
B
or
or
Ball
Ball
ens
ens
ens
ens
ut
t
re s
re s
inpu
re s
re s
gs /
gs /
l inp
atu
atu
atu
atu
put
put
rin
rin
ion
ion
trol
ntro
C
C
per
per
Bea
Bea
per
per
rol in
rol in
tect
tect
, CC
, CC
n
Tem
Tem
e Co
e Co
Tem
Tem
eve
eve
ions
ns
pro
pro
, CE
, CE
ont
ont
55
55
io
l
l
l
l
a
a
igna
igna
-Sle
-Sle
logu
logu
rnal
rnal
Sign
Sign
TUV
TUV
= IP
= IP
rnal
rnal
ens
ens
fog
fog
MC
MC
e
e
FG S
FG S
AHB
AHB
Exte
Exte
Dim
Dim
Ana
Ana
Inte
Inte
IP >
IP >
Pag
Pag
Salt
Salt
DC blower fans
PW
PW
UL,
UL,
RD
RD
25
gs
earin
sor
all B
sor
sen
sen
s/B
ut
ure
l inp
ure
ring
put
ion
erat
erat
ntro
C
Bea
rol in
tect
, CC
mp
mp
e Co
eve
ions
pro
, CE
l Te
ont
l Te
55
al
l
igna
-Sle
logu
Sign
T UV
= IP
ens
fog
rna
MC
rna
e
FG S
AHB
Exte
Dim
Ana
Inte
IP >
Pag
Salt
PW
UL,
RD
Axial Fans
Series mm
DE07015 70 × 15 Yes 61
DA07020 70 × 20 Yes 62
DV07020 70 × 20 Yes 63
DY7025 70 × 25 Yes 64
DS07025 70 × 25 Yes 65
DS08015 80 × 15 Yes 66
DA08020 80 × 20 Yes 67
DS08020 80 × 20 Yes 68
DBTA0825 80 × 25 Yes 69
DL08025 80 × 25 Yes 70
DS08025 80 × 25 Yes 71
DASA0832 80 × 32 Yes 72
DATA0838 80 × 38 Yes 73
2B08038 80 × 38 Yes 74
Please note that these special versions are not possible for all
2B08038 80 × 38 Yes 75
voltages and speeds, and not in all combinations.
DYTB0838 80 × 38 Yes 76
DAKA0925 92 × 25 Yes 77 The special versions are designed for specific customers and
DL09225 92 × 25 Yes 78 projects. As a rule they are not availale off the shelf and are tied to
DS09225 92 × 25 Yes 79 minimum volumes.
DYTB0925 92 × 25 Yes 80
Please consult your customer support representative about the
DCTA0938 92 × 38 Yes 81
feasibility of your special variant.
DESA0938 92 × 38 Yes 82
2B09238 92 × 38 Yes 83
2B09238 92 × 38 Yes 84
DATA1225 120 × 25 Yes 85
DATA1225 120 × 25 Yes 86
DBTA1225 120 × 25 Yes 87
DBTA1225 120 × 25 Yes 88
DS12025 120 × 25 Yes 89
DA12032 120 × 32 Yes 90
DATA1232 120 × 32 Yes 91
DAKA1238 120 × 38 Yes 92
DATA1238 120 × 38 Yes 93
DBTB1238 120 × 38 Yes 94
2B12038 120 × 38 Yes 95
DB12738 127 × 38 Yes 96
DB12738 127 × 38 Yes 97
DATA1338 130 × 38 Yes 98
DATA1338 130 × 38 Yes 99
DATA1525 150 × 25 Yes 100
DATA1525 150 × 25 Yes 101
DATA1551 150 × 51 Yes 102
DB15051 150 × 51 Yes 103
DA17251 172 × 51 Yes 104
DATA2070 200 × 70 Yes 105
26
DASA SERIES
25×25×10 mm 5v
Information
Operating Voltage Range
Acoustic Noise
Rated Voltage
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PART NO. SIGNAL B.T.S.R VDC VDC Amp Watt R.P.M. m3/min CFM mmH2O IN H2O dB-A hours
* DASA2510 _5U -FG/RD B R 5 3 to 5.5 0.25 1.25 13000 0.179 3.16 4.7 0.185 27.9 50000
DASA2510 _5H -FG/RD B R 5 3 to 5.5 0.13 0.65 11000 0.151 2.67 3.72 0.147 24.4 50000
DASA2510 _5M -FG/RD B R 5 3 to 5.5 0.10 0.5 9000 0.062 2.16 2.27 0.090 19.8 50000
DASA2510 _5L -FG/RD B R 5 3 to 5.5 0.04 0.2 7000 0.042 1.5 1.58 0.062 17.3 50000
DC axial fans
5.5 ±0.3
10.0(REF.)
10 .0
90 ±10
0.20 5.0
DC blower fans
0.18 4.5
0.16 4.0
13000RPM
0.14 3.5
0.12
AIR PRESSURE
3.0
20±0.3
11000RPM
23
0.10 2.5
9000RPM Ø23
0.08 2.0 .4
7000RPM
0.06 1.5
0.04 1.0
0.02 0.5
2 0.0
0.00 0.0 ±0.3
0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 (M3/MIN) 25 .0
±0.5
Ø2.8
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3
AIR FLOW
27
Ø 3 0 × 7 0 m m 5 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA0307R5H -FG/RD R 3.3 2.5 to 6.0 0.06 0.198 4200 0.052 1.85 0.87 0.034 18.6 70000
2.2
0.08 2.0
2-1.0±0.3
2-Ø
1.8 2.5± 2-1.8±0.3
0.07 0.3
1.6
0.06
1.4
36.0±0.3
0.05
310.0±10.0
1.2
AIR PRESSURE
0.04 1.0
Ø28.4±0.3
36.0±0.3
0.03 0.8
4200 RPM
0.6
0.02
10.0(REF.)
0.4
0.01 Ø30 0.95±0.30
0.2 .4±0
2-Ø2.5±0.3
.3 6.9±0.3
0.00 0.0
0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 (M3/MIN)
(INCH-H2O)
(MM-H2O)
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 (CFM)
AIR FLOW
28
DB SERIES
36×36×28 mm
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #28 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 48g (1.69 OZ)
Information
Operating Voltage Range
Acoustic Noise
Rated Voltage
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PART NO. SIGNAL B.T.S.R VDC VDC Amp Watt R.P.M. m3/min CFM mmH2O IN H2O dB-A hours
DB03628_12S -FG / RD B 12 7.0 to 13.2 0.66 7.92 19000 0.560 19.75 53.25 2.096 58.0 110000
DC axial fans
60.0
DC blower fans
±0.5
28.0
2.00 50.0
1.60 40.0
10(REF.)
310 ±10
19000 RPM
AIR PRESSURE
1.20 30.0
Ø37
.4
29.5
35.4
0.80 20.0
0.40 10.0
Ø3.5
0.00 0.0 Ø3.5 ±0.3
29.5 ±0.3
0.00 0.10 0.20 0.30 0.40 0.50 0.60 (M3/MIN) ±0.3
(INCH-H2O)
36.0
(MM-H2O)
±0.5
AC fans
AIR FLOW
29
DA SER IES
3 8 × 3 8 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #28 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 30.5g (1.076 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
F3820_12M FG B 12 10.8 to 13.2 0.12 1.44 6700 0.177 6.255 5.52 0.217 31.12 70000
* F3820_12H FG B 12 10.8 to 13.2 0.20 2.40 8900 0.245 8.634 10.06 0.396 38.22 70000
F3820_12U FG B 12 10.8 to 13.2 0.32 3.84 11000 0.3096 10.931 14.799 0.5826 43.83 70000
0.61 15.6
0. 2
20±
11000RPM 3
0.51 13.0
3
0.41 10.4
AIR PRESSURE
8900RPM
10.0(REF.)
310 ±10
0.31 7.8
30±0.1
Ø38
36
6700RPM
0.20 5.2
0.10 2.6
Ø3.3
± 0.1
Ø3.3
30±0 ± 0.1
. 1
0.00 0.0 38±
0.00 0.06 0.12 0.18 0.24 0.30
3
0.36 (M /MIN) 0.2
(CFM)
(INCH-H2O)
(MM-H2O)
30
Company profile
DA SER IES
3 8 × 3 8 × 2 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 40g (1.41 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
F3828_12M RD B 12 10.8 to 13.2 0.18 2.16 6250 0.179 6.345 6.234 0.245 33.85 70000
* F3828_12H RD B 12 10.8 to 13.2 0.30 3.60 10000 0.303 10.718 15.558 0.612 43.15 70000
DC axial fans
0.88 22.0
0.80 20.0
0.72 18.0
0.64 16.0 0. 2
DC blower fans
± 3
2 8.0
0.56 14.0 3
10000 RPM
0.48 12.0
AIR PRESSURE
10.0(REF.)
310 ±10
0.40 10.0
6250 RPM
30±0.1
0.32 8.0
36
Ø38
0.24 60
38 ±
0. 2
0.00 0.0
0.00 0.03 0.06 0.09 0.12 0.15 0.18 0.21 0.24 0.27 0.30 0.33 0.36 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 1.1 2.1 3.2 4.2 5.3 6.4 7.4 8.5 9.5 10.6 11.6
AC fans
AIR FLOW
31
DB SER IES
3 8 × 3 8 × 2 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 40g (1.41 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DB03828_12L -FG / RD B 12 7.0 to 13.2 0.11 1.32 8000 0.267 9.44 10.02 0.394 38.0 120000
DB03828_12M -FG / RD B 12 7.0 to 13.2 0.14 1.68 10000 0.353 12.46 15.88 0.625 44.0 120000
DB03828_12H -FG / RD B 12 7.0 to 13.2 0.29 3.48 13000 0.462 16.30 25.91 1.020 51.0 110000
DB03828_12U -FG / RD B 12 7.0 to 13.2 0.50 6.00 15000 0.543 19.16 34.71 1.367 55.0 100000
* DB03828_12S -FG / RD B 12 7.0 to 13.2 0.65 7.80 17000 0.589 20.83 42.41 1.669 59.0 90000
1.60 40.0
28.0
310±10
15000RPM
AIR PRESSURE
1.00
24.0 13000RPM
10000RPM Ø 38
30.0±0.3
0.80 .0
20.0
8000RPM
36.0
16.0
0.60
12.0
0.40
8.0 Ø3.5
Ø3.5 ±0.3
0.20 30.0 ±0.3
4.0 ±0.3
38.0
±0.5
0.00 0.0
0.00 0.10 0.20 0.30 0.40 0.50 0.60
(M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 5.0 10.0 15.0 20.0
AIR FLOW
32
3 8 × 3 8 × 2 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #28 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from inlet side
* Weight: 40g (1.28 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTA0328B2E -FG/RD B 12 5.0 to 13.2 0.14 1.68 10000 0.315 11.14 13.63 0.537 40.0 70000
DBTA0328B2L -FG/RD B 12 5.0 to 13.2 0.18 2.16 12000 0.387 13.70 20.14 0.793 46.0 70000
DBTA0328B2M -FG/RD B 12 5.0 to 13.2 0.24 2.88 14000 0.434 15.38 27.50 1.083 50.0 70000
DBTA0328B2H -FG/RD B 12 5.0 to 13.2 0.32 3.84 16000 0.494 17.48 37.05 4.459 54.0 70000
DC axial fans
DBTA0328B2U -FG/RD B 12 5.0 to 13.2 0.42 5.04 18000 0.558 19.75 46.72 1.839 57.0 70000
* DBTA0328B2S -FG/RD B 12 5.0 to 13.2 0.55 6.6 20000 0.629 22.21 58.92 2.482 58.0 70000
60.0
2.25 20000RPM
54.0
0.3
2.00 18000RPM 28±
.3
48.0
4±0 Ø41
DC blower fans
1.75 16000RPM
42.0 4 ±0.3
1.50 14000RPM
36.0
10.0(REF.)
1.25
12000RPM
310.0±10
30.0
AIR PRESSURE
10000RPM
1.00
24.0
30.0
36.0
0.75
18.0
0.50 12.0
0.25 6.0
30.0 Ø3.5 Ø3.5
±0.
0.00 0.0 38.0 3
0.00 0.10 0.20 0.30 0.40 0.50 0.60 (M3/MIN) ±0.5
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 UNIT: mm
AIR FLOW
33
4 0 × 4 0 × 1 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 16.55g (0.584 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DAKA0410 _12E -FG / RD B 12 5.0 to 13.2 0.07 0.84 4600 0.153 5.39 2.29 0.090 21.27 70000
DAKA0410 _12L -FG / RD B 12 5.0 to 13.2 0.09 1.08 5400 0.196 6.93 3.15 0.336 24.08 70000
DAKA0410 _12M -FG / RD B 12 5.0 to 13.2 0.11 1.32 6200 0.219 7.8 4.17 0.481 28.01 70000
* DAKA0410 _12H -FG / RD B 12 5.0 to 13.2 0.14 1.68 7000 0.252 8.96 5.32 0.677 31.25 70000
DAKA0410 _12U -FG / RD B 12 5.0 to 13.2 0.17 2.04 8000 0.296 10.37 6.79 0.481 35.16 70000
8.8
0.33
8.0 ±0.3
0.30 11.0
7.2 .3
0.27 2 ±0
6.4
0.24
8000RPM
5.6
AIR PRESSURE
0.21
7000RPM
4.8
0.18
32.0 ±0.3
6200RPM
270 ±10
4.0
0.15
Ø 38
3.2
5400RPM .0
0.12
4600RPM
0.09 2.4
0.06 1.6
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 1.1 2.2 3.3 4.4 5.5 6.6 7.7 8.8 9.9 11.0 12.1
AIR FLOW
34
DS SER IES
4 0 × 4 0 × 1 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 15g (0.43 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS04010_12L -FG B R 12 5.0 to 13.2 0.08 0.96 3600 0.141 4.97 1.28 0.050 18.0 70000
DS04010_12M -FG B R 12 5.0 to 13.2 0.10 1.20 4000 0.140 4.95 1.61 0.064 18.7 70000
* DS04010_12H -FG B R 12 5.0 to 13.2 0.11 1.32 5000 0.195 6.89 2.47 0.097 23.7 70000
DS04010_12U -FG R 12 5.0 to 13.2 0.14 1.68 6500 0.238 8.42 4.02 0.158 30.4 50000
DC axial fans
DS04010_12S -FG R 12 5.0 to 13.2 0.30 3.60 8500 0.347 12.24 7.02 0.276 37.8 50000
9.0
DC blower fans
±50.
10.5
0.32 8.1 2.5
0.28 7.2
8500RPM
6.3
0.24
6500RPM
5.4
0.20 5000RPM
310±10
4.5
10(REF.)
□32±0.3
4000RPM
AIR PRESSURE
0.16 Ø43
□39
3.6
0.12
3600RPM
2.7
0.08
1.8
(CFM)
(MM-H2O)
0.0 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 11.7 13.0
AC fans
AIR FLOW
35
4 0 × 4 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 35g (1.23 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DAKA0420 _2M FG B 12 5.0 to 13.2 0.30 3.6 8000 0.335 11.84 8.85 0.348 38.98 70000
* DAKA0420 _2H FG B 12 5.0 to 13.2 0.40 4.8 10000 0.425 14.94 13.40 0.528 44.84 70000
DAKA0420 _2U FG B 12 5.0 to 13.2 0.60 7.2 12000 0.509 17.97 18.80 0.740 50.25 70000
DAKA0420 _2S FG B 12 5.0 to 13.2 0.80 9.6 14000 0.594 20.95 25.90 1.020 52.83 70000
DAKA0420 _2F FG B 12 5.0 to 13.2 1.20 14.4 16000 0.686 24.20 33.60 1.323 57.02 70000
38.5
1.40 35.0
1.26 31.5
±0.3
20.0 3.75
1.12 28.0
16000RPM
0.98 14000RPM
24.5
0.84 12000RPM
21.0
10(REF.)
AIR PRESSURE
10000RPM
310 ±5
0.70 17.5
0.56
8000RPM
14.0
32.0
9.0
38.0
Ø3
0.42 10.5
0.28 7.0
(MM-H2O)
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5
AIR FLOW
36
4 0 × 4 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #28 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 25g (0.88 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTA0420B_2E -FG / RD B 12 7.0 to 13.2 0.08 0.96 8000 0.267 9.43 8.92 0.351 32.9 70000
DBTA0420B_2L -FG / RD B 12 7.0 to 13.2 0.11 1.32 10000 0.332 11.73 13.96 0.549 40.0 70000
DBTA0420B_2M -FG / RD B 12 7.0 to 13.2 0.17 2.04 12000 0.405 14.31 20.06 0.789 44.3 70000
DBTA0420B_2H -FG / RD B 12 7.0 to 13.2 0.25 3.00 14000 0.476 16.82 27.34 1.073 48.9 70000
DC axial fans
* DBTA0420B_2U -FG / RD B 12 7.0 to 13.2 0.41 4.92 16000 0.561 19.82 36.55 1.438 52.9 70000
0.90 22.8
310±10
10(REF.)
8000 RPM
Ø41
30.0±0.3
40.0±0.5
0.75 19.0 .6
0.60 15.2
0.45 11.4
0.30 7.6
0.15 3.8 Ø3.5
32.0 ±0.3
0.00 0.0 ±0.3 Ø3.5
±0.3
0.00 0.06 0.12 0.18 0.24 0.30 0.36 0.42 0.48 0.54 0.60 0.66 (M3/MIN)
40.0
±0.5
(CFM)
AC fans
(INCH-H2O)
(MM-H2O)
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0
AIR FLOW
37
DS SER IES
4 0 × 4 0 × 2 0 m m 1 2 v ,2 4 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DS04020_12L -FG/RD B R 12 7.0 to 13.2 0.10 1.20 4500 0.155 5.48 2.64 0.104 22.3 70000
DS04020_12M -FG/RD B R 12 7.0 to 13.2 0.15 1.80 6200 0.208 7.35 5.12 0.202 26.5 70000
DS04020_12H -FG/RD B R 12 7.0 to 13.2 0.20 2.40 7600 0.265 9.37 7.46 0.294 32.2 70000
DS04020_12U -FG/RD B R 12 7.0 to 13.2 0.25 3.00 9000 0.312 11.01 9.88 0.389 36.7 70000
DS04020_12S -FG/RD B 12 7.0 to 13.2 0.40 4.80 13000 0.450 15.90 20.31 0.799 46.2 70000
DS04020_24S -FG/RD B 24 10.0 to 26.4 0.30 7.20 10500 0.363 12.8 12.68 0.499 40.2 70000
0.84
21.0
0.78 19.6
0.5
0.72 20±
18.2
0.66 16.8
13000RPM
0.60 15.4
10500RPM
0.54 14.0
9000RPM
310±10
12.6
□ 32±0.3
0.48
7600RPM Ø43
10(REF.)
11.2
□39
0.42
6200RPM
AIR PRESSURE
9.8
0.36 4500RPM
8.4
0.30
7.0
0.24 Ø4.3
±0.3
5.6 Ø4.3
□3 ±0.3
0.18 2±0
4.2 .3
□4
0.12 2.8 0±0
.5
0.06 1.4
0.00 0.0
0.00 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.32 0.36 0.40 0.44 0.48(M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 11.7 13.0 14.3 15.6 16.9
AIR FLOW
38
DB SER IES
4 0 × 4 0 × 2 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 40g (1.41 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DB04028_12L -FG / RD B 12 7.0 to 13.2 0.14 1.68 8000 0.401 13.86 11.60 0.456 40.0 120000
DB04028_12M -FG / RD B 12 7.0 to 13.2 0.23 2.76 9500 0.449 15.85 17.57 0.692 45.0 120000
DB04028_12H -FG / RD B 12 7.0 to 13.2 0.38 4.56 11000 0.542 18.73 23.38 0.920 50.5 110000
DB04028_12U -FG / RD B 12 7.0 to 13.2 0.55 6.60 13000 0.673 23.78 33.65 1.324 54.0 100000
DC axial fans
* DB04028_12S -FG / RD B 12 7.0 to 13.2 0.64 7.68 15000 0.703 24.82 41.61 1.638 58.0 100000
44.2
1.69
40.8
1.56
37.4 0.5 2
1.43 28±
34.0
DC blower fans
1.30
30.6
10(REF.)
1.17
27.2
AIR PRESSURE
310±10
1.04 15000RPM
23.8
32.0±0.3
0.91
13000RPM Ø41
38.0
0.78 20.4
11000RPM
0.65 17.0
9500RPM
0.52 13.6
8000RPM Ø3.5
0.39 10.2 ±0.3
32.0 Ø3.5
6.8 ±0. ±0.3
40.0 3
0.26
±0.5
0.13 3.4
0.00 0.0
0.00 0.07 0.14 0.21 0.28 0.35 0.42 0.49 0.56 0.63 0.70 0.77 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
AC fans
39
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTA0428_2L -FG/RD B 12 7.0 to 13.8 0.11 1.32 8500 0.349 12.34 10.60 0.417 38.7 120000
DBTA0428_2M -FG/RD B 12 7.0 to 13.8 0.13 1.56 10000 0.406 14.34 14.18 0.558 42.4 110000
DBTA0428_2H -FG/RD B 12 7.0 to 13.8 0.35 4.20 14500 0.586 20.68 26.33 1.037 52.9 90000
DBTA0428_2U -FG/RD B 12 7.0 to 13.2 0.45 5.40 16000 0.663 23.42 35.80 1.409 55.4 70000
* DBTA0428_2S -FG/RD B 12 7.0 to 13.2 0.62 7.44 18000 0.754 26.64 44.52 1.753 58.0 70000
50.0
1.80 45.0
18000RPM
1.60 40.0
16000RPM
1.40 35.0
±0.5
14500RPM
10(REF.)
1.20 28.0
30.0
AIR PRESSURE
10000RPM
1.00 25.0
310±10
8500RPM
0.80 20.0
Ø41
0.60 15.0 .0
□ 32.0
□ 38.0
0.40 10.0
0.20 5.0
0 0
0 0.20 0.40 0.60 0.80 (M3/MIN) □3 Ø3.5
2±0 ±0.3 Ø3.5
.3 ±0.3
(CFM) □4
(INCH-H2O)
0.0±
(MM-H2O)
0.5
0 5.0 10.0 15.0 20.0 25.0 30.0
AIR FLOW
40
DV SER IES
4 0 × 4 0 × 2 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 40g (1.41 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DV04028_12E -FG / RD B 12 7.0 to 13.2 0.10 1.20 8000 0.261 9.20 9.30 0.366 31.3 120000
DV04028_12L -FG / RD B 12 7.0 to 13.2 0.15 1.80 10000 0.340 12.00 14.60 0.575 36.5 120000
DV04028_12M -FG / RD B 12 7.0 to 13.2 0.20 2.40 12000 0.408 14.40 20.31 0.800 41.3 120000
DV04028_12H -FG / RD B 12 7.0 to 13.2 0.30 3.60 14000 0.481 17.00 27.60 1.087 45.4 110000
DC axial fans
* DV04028_12U -FG / RD B 12 7.0 to 13.2 0.46 5.52 16500 0.581 20.50 37.30 1.469 48.8 100000
40.0
DC blower fans
16500RPM
1.40 35.0
0.3
1.20 28±
30.0 4
14000RPM
1.00 25.0
AIR PRESSURE
0.80 20.0
10.0(REF.)
310.0±10
12000RPM
0.60 15.0
32.0
10000RPM
38.0
Ø41
0.40 10.0
8000RPM
0.20 5.0
Ø3.5
0.00 0.0 ±0.3
0.00 0.15 0.30 0.45 0.60 (M3/MIN) 32.0 Ø3.5
±0.3 ±0.3
AC fans
(INCH-H2O)
40.0
±0.5
(MM-H2O)
(CFM)
AIR FLOW
41
DF SER IES
4 0 × 4 0 × 5 6 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #28 or Equivalent
* Impeller: 5 Blades inlet, 3 Blades outlet
* Rotational direction CCW view from front face
* Weight: 96g (3.39 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DF04056_12M -FG / RD B 12 7.0 to 13.2 0.85 10.20 11000 0.738 26.05 38.01 1.496 58.0 70000
DF04056_12H -FG / RD B 12 7.0 to 13.2 1.25 15.00 13900 0.845 29.83 51.51 2.028 61.5 70000
* DF04056_12U -FG / RD B 12 7.0 to 13.2 1.50 18.00 15600 0.918 32.41 66.94 2.635 64.5 70000
70.0
0.5 4
2.6 15600RPM 56.0±
2.4
60.0
2.2 5
13900RPM
2.0 50.0
1.8
13300RPM
1.6
Ø41.0
□ 32.0
40.0
□ 38.0
AIR PRESSURE
1.4
11000RPM
1.2 30.0
1.0
0.8 20.0
Ø3.5±
0.6 0.3
0.4 10.0
Ø3.5±
10(REF.)
□ 32
310±10
0.2
.0±0.3 0.3
0.0 0.0 □ 40
.0±0.5
0.00 0.15 0.30 0.45 0.60 0.75 0.90 1.05 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
AIR FLOW
42
4 0 × 4 0 × 5 6 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #28 or Equivalent
* Impeller: 5 Blades inlet, 3 Blades outlet
* Rotational direction CCW view from front face
* Weight: 96g (3.39 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DFTA0456_2M -FG / RD B 12 7.0 to 13.2 0.8 9.6 16500 0.738 26.06 61.74 2.43 63.5 70000
DFTA0456_2H -FG / RD B 12 7.0 to 13.2 1.0 12.0 17100 0.793 28.00 68.33 2.69 64.0 70000
* DFTA0456_2U -FG / RD B 12 7.0 to 13.2 1.3 15.6 18000 0.812 28.68 71.91 2.83 64.5 70000
DC axial fans
80.0
3.0
18000/17000RPM 5
±0.5
2.8 70.0 56.0
2.6
DC blower fans
17100/16100RPM
2.4 60.0
2.2 16500/14500RPM
2.0
50.0
1.8
32.0
Ø41
38.0
.0
1.6 40.0
1.4
AIR PRESSURE
1.2
30.0
1.0
±0.3
10(REF.)
0.6
Ø3.5
0.4 10.0 32.0 ±0.3
±0.3
0.2 40.0
±0.5
0.0 0.0
0.00 0.15 0.30 0.45 0.60 0.75 0.90 1.05 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
AIR FLOW
AC fans
43
DS SER IES
5 0 × 5 0 × 1 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #24 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 20g (0.71 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS05010_12E -FG R 12 5.0 to 13.2 0.10 1.20 3000 0.184 6.51 1.53 0.060 18.7 70000
DS05010_12L -FG R 12 5.0 to 13.2 0.14 1.68 4000 0.235 8.28 2.57 0.101 23.8 70000
DS05010_12M -FG R 12 5.0 to 13.2 0.17 2.04 5000 0.301 10.62 3.75 0.148 32.2 70000
* DS05010_12H -FG R 12 5.0 to 13.2 0.22 2.64 6500 0.384 13.55 6.19 0.244 36.6 70000
DS05010_12U -FG R 12 5.0 to 13.2 0.35 4.20 7500 0.466 16.51 7.74 0.305 39.4 70000
0.32 8.1
0.28 7.2
7500RPM
±0.5
0.24
6.3
6500RPM 10.5
5.4 5000RPM
0.20
4000RPM
4.5
AIR PRESSURE
0.16
3000RPM
310±10
3.6
10(REF.)
□40±0.3
0.12
□47
2.7 Ø43
0.08
1.8
0.04 0.9
Ø4.3 Ø4.3
□40 ±0.3 ±0.3
± 0.3
0.00 0.0
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 (M3/MIN) □50
±0.5
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 1.7 3.4 5.1 6.8 8.5 10.2 11.9 13.6 15.3 17.0
AIR FLOW
44
DA SER IES
5 0 × 5 0 × 1 5 m m 1 2 v ,5 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA05015_12E -FG B R 12 5.0 to 13.2 0.09 1.08 3600 0.278 9.80 2.12 0.084 23.4 70000
DA05015_12L -FG B R 12 5.0 to 13.2 0.12 1.44 4200 0.340 11.90 2.94 0.116 26.7 70000
DA05015_12M -FG B R 12 5.0 to 13.2 0.15 1.80 4700 0.379 13.40 3.48 0.137 28.3 70000
* DA05015_12H -FG B 12 5.0 to 13.2 0.20 2.40 5400 0.425 15.01 4.54 0.179 31.5 70000
DC axial fans
DA05015_12U -FG B 12 5.0 to 13.2 0.40 4.80 6000 0.495 17.49 5.85 0.230 35.5 70000
DA05015_05E -FG B 5 4.0 to 5.5 0.15 0.75 3600 0.278 9.80 2.12 0.084 23.4 70000
DA05015_05L -FG B 5 4.0 to 5.5 0.20 1.00 4200 0.340 11.99 2.94 0.116 26.7 70000
DA05015_05M -FG B 5 4.0 to 5.5 0.25 1.25 4700 0.379 13.40 3.48 0.137 28.3 70000
DA05015_05H -FG B 5 4.0 to 5.5 0.30 1.50 5400 0.425 15.01 4.54 0.179 31.5 70000
DA05015_05U -FG B 5 4.0 to 5.5 0.40 2.00 6000 0.495 17.49 5.85 0.230 35.5 70000
6.3
0.24
DC blower fans
6000RPM
5.6
0.21
5400RPM
4.9 .5
0.18 4700RPM 15±0
4.2
4200RPM
AIR PRESSURE
0.15
3.5
3600RPM
0.12
310±10
2.8
0.09 Ø52
10(REF.)
2.1
40±0.3
48
0.06 1.4
0.03 0.7
Ø4.3±
0.00 0.0 40±0 0.3 Ø4.3±
.3 0.3
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 (M3/MIN) 50±0
.5
(INCH-H2O)
(CFM)
AC fans
(MM-H2O)
0.0 1.8 3.6 5.4 7.2 9.0 10.8 12.6 14.4 16.2 18.0
AIR FLOW
45
DS SER IES
5 0 × 5 0 × 2 0 m m 1 2 v ,2 4 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS05020_12L -FG/RD B R 12 7.0 to 13.2 0.15 1.80 3000 0.263 9.28 1.93 0.076 19.2 70000
DS05020_12M -FG/RD B R 12 5.0 to 13.2 0.20 2040 4000 0.341 12.04 3.30 0.130 25.7 70000
* DS05020_12H -FG/RD B R 12 5.0 to 13.2 0.25 3.00 5000 0.417 14.74 5.12 0.202 32.3 70000
DS05020_12U -FG/RD B R 12 5.0 to 13.2 0.30 3.60 6000 0.536 18.94 6.95 0.274 37.8 70000
DS05020_12S -FG/RD B 12 5.0 to 13.2 0.40 4.80 7000 0.605 21.38 9.63 0.379 41.5 70000
DS05020_24U -FG/RD R 24 10.0 to 26.4 0.30 7.30 6000 0.536 18.94 6.95 0.274 37.8 70000
12.1
0.44
11.0
.5
0.40
9.9
20±0 2.5
0.36 7000RPM
8.8
0.32 6000RPM
7.7
0.28 5000RPM
AIR PRESSURE
6.6
0.24 4000RPM
□ 40±0.3
310±10
5.5
0.20
□ 47
3000RPM
10(REF.)
Ø43
0.16 4.4
0.12 3.3
0.08 2.2
(CFM)
(MM-H2O)
0.0 2.2 4.4 6.6 8.8 11.0 13.2 15.4 17.6 19.8 22.0
AIR FLOW
46
DA SER IES
6 0 × 6 0 × 1 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 11 Blades
* Rotational direction CCW view from front face
* Weight: 25g (0.88 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA06010_12E -FG/RD B 12 7.0 to 13.2 0.10 1.20 3000 0.382 13.49 1.67 0.066 24.3 70000
DA06010_12L -FG/RD B 12 7.0 to 13.2 0.17 2.04 3600 0.452 15.98 2.43 0.096 28.9 70000
DA06010_12M -FG/RD B 12 7.0 to 13.2 0.20 2.40 4200 0.579 20.46 3.39 0.134 33.4 70000
DA06010_12H -FG/RD B 12 7.0 to 13.2 0.29 3.48 4800 0.673 23.78 4.30 0.169 37.3 70000
DC axial fans
* DA06010_12U -FG/RD B 12 7.0 to 13.2 0.40 4.80 5400 0.716 25.29 5.48 0.216 40.0 70000
7.0
0.27
DC blower fans
6.3
0.24 05.
5400RPM 10±
5.6
0.21 4800RPM
4.9
0.18 4200RPM
AIR PRESSURE
4.2
3600RPM
0.15
3.5
310±10
0.12
3000RPM
10(REF.)
2.8
□50±0.3
□57.5
0.09 Ø67
2.1 .5
0.06 1.4
0.03 0.7 Ø6
□50 Ø4..35X6.0
± ±0.3
0.00 0.0 0.3
(M3/MIN)
0.00 0.07 0.14 0.21 0.28 0.35 0.42 0.49 0.56 0.63 0.70 □60 Ø4.3±
±0.5
(INCH-H2O)
0.3
AC fans
(CFM)
(MM-H2O)
0.0 2.6 5.2 7.8 10.4 13.0 15.6 18.2 20.8 23.4 26.0
AIR FLOW
47
DA SER IES
6 0 × 6 0 × 1 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 36g (1.27 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* F6015_12L FG B 12 10.8 to 13.2 0.10 1.20 3000 0.415 14.678 2.246 0.088 24.6 70000
F6015_12M FG B 12 10.8 to 13.2 0.15 1.80 4000 0.542 19.132 3.955 0.155 32.93 70000
F6015_12H FG B 12 10.8 to 13.2 0.15 1.80 4500 0.613 21.638 4.94 0.194 35.54 70000
F6015_12U FG B 12 10.8 to 13.2 0.35 4.20 5500 0.755 26.651 7.317 0.288 41.55 70000
8.8
±0.3
8.0 15.0
±0.3
3. 0
7.2 .3
3. 0 ±0
6.4
5.6
10(REF.)
310 ±10
5500RPM
4.8
AIR PRESSURE
4500RPM
4.0
50.0±0.3
4000RPM
57.0
3.2
Ø61
.0
3000RPM
2.4
1.6
0.8
50.0 Ø4.5
0.0
±0.3 Ø4.5
0.00 0.08 0.16 0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80 0.88 0.96 (M3/MIN) 60.0
±0.5
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 2.8 5.6 8.5 11.3 14.1 16.9 19.8 22.9 25.4 28.2 31.1
AIR FLOW
48
DA SER IES
6 0 × 6 0 × 1 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA06015_12E -FG/RD B R 12 7.0 to 13.2 0.111 1.32 3000 0.417 14.73 2.05 0.081 26.1 70000
* DA06015_12L -FG/RD B R 12 7.0 to 13.2 0.14 1.68 3600 0.515 18.18 3.01 0.119 30.3 70000
DA06015_12M -FG/RD B R 12 7.0 to 13.2 0.18 2.16 4200 0.609 21.51 4.01 0.158 35.1 70000
DA06015_12H -FG/RD B R 12 7.0 to 13.2 0.24 2.88 4800 0.716 25.30 5.26 0.207 39.1 70000
DC axial fans
DA06015_12U -FG/RD B R 12 7.0 to 13.2 0.35 4.20 5400 0.806 28.48 6.60 0.260 40.8 70000
7.2
0.27 5400RPM
DC blower fans
05.
6.4 15±
0.24 4800RPM
5.6
0.21 4200RPM
4.8
0.18
3600RPM
AIR PRESSURE
4.0
310±10
0.15
3000RPM
□ 50±0.3
10(REF.)
□ 57.5
3.2
0.12 Ø67
.5
0.09 2.4
0.06 1.6
Ø 5
Ø46..3X 6
0.03 0.8 ±.00.3 Ø4.±
□ 50 3 0.3
±0.3
0.00 0.0 □ 60
0.00 0.08 0.16 0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80 0.88 (M3/MIN) ±0.5
(CFM)
AC fans
(INCH-H2O)
(MM-H2O)
0.0 2.9 5.8 8.7 11.6 14.5 17.4 20.3 23.2 26.1 29.0 31.9
AIR FLOW
49
DS SER IES
6 0 × 6 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 50g (1.43 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS06020_12E -FG B T R 12 5.0 to 13.2 0.08 0.96 2200 0.306 10.82 1.43 0.056 20.2 70000
DS06020_12L -FG B T R 12 5.0 to 13.2 0.10 1.20 3000 0.424 14.96 2.47 0.097 24.9 70000
DS06020_12M -FG B T R 12 5.0 to 13.2 0.15 1.80 4000 0.626 22.10 4.22 0.166 31.7 70000
* DS06020_12H -FG B T R 12 5.0 to 13.2 0.23 2.76 5000 0.759 26.80 6.36 0.251 39.9 70000
DS06020_12U -FG B 12 5.0 to 13.2 0.35 4.20 5800 0.917 32.37 8.47 0.333 42.8 70000
DS06020_12S -FG B 12 5.0 to 13.2 0.45 5.40 6800 1.113 39.32 10.67 0.420 47.4 70000
0.45
11.0
0.40 10.0
6800RPM 0.5
0.35 9.0 20 ±
4
5800RPM
8.0
0.30 5000RPM
7.0
4000RPM
10(REF.)
0.25
6.0
AIR PRESSURE
310±10
3000RPM
0.20 5.0
2200RPM
50±0.3
57.5
4.0 Ø66
0.15
3.0
0.10
2.0
50±0 Ø4.3± Ø4.3±
0.05 .3 0.3 0.3
1.0 60 ±
0.5
0.00 0.0
0.00 0.11 0.22 0.33 0.44 0.55 0.66 0.77 0.88 0.99 1.10 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
AIR FLOW
50
6 0 × 6 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 74g (2.61 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DAKA0625_12E FG B 12 5.0 to 13.2 0.4 4.8 3600 0.590 20.82 4.36 0.172 28.05 70000
DAKA0625_12L FG B 12 5.0 to 13.2 0.5 6.0 4400 0.740 26.11 6.57 0.259 33.55 70000
DAKA0625_12M FG B 12 5.0 to 13.2 0.6 7.2 5200 0.845 29.82 9.02 0.355 38.81 70000
* DAKA0625_12H FG B 12 5.0 to 13.2 0.7 8.4 6000 1.009 35.60 12.06 0.475 43.66 70000
DC axial fans
DAKA0625_12U FG B 12 5.0 to 13.2 0.8 9.6 7000 1.166 41.14 15.80 0.622 47.21 70000
DAKA0625_12S FG B 12 5.0 to 13.2 1.0 12.0 8000 1.342 47.38 20.40 0.801 50.61 70000
DAKA0625_12F FG B 12 5.0 to 13.2 1.2 14.4 9000 1.506 53.17 24.90 0.980 55.81 70000
±0.3
26.0
1.00
25.0
.3
0.90
23.4
5±0
DC blower fans
9000RPM
20.8 .3
0.80 5±0
8000RPM
18.2
0.70
15.6
7000RPM
0.60
13.0
6000RPM
0.50
50.0 ±0.3
AIR PRESSURE
5200RPM
328±10
0.40 10.4
4400RPM
7.8 Ø 57
0.30 .6
3600RPM
0.20 5.2
0.10 2.6
0.00 0.0
0.00 0.15 0.30 0.45 0.60 0.75 0.90 1.05 1.20 1.35 1.50 1.65 1.80 (M3/MIN) 50.0 Ø4.5
60.0 ±0.3
(CFM) ±0.5
(INCH-H2O)
(MM-H2O)
0.0 5.4 10.8 16.2 21.6 27.0 32.4 37.8 43.2 48.6 54.0 59.4
AC fans
AIR FLOW
51
DS SER IES
6 0 × 6 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 55g (1.940 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS06025_12X -FG B R 12 7.0 to 13.2 0.10 1.20 2000 0.309 10.92 1.38 0.054 18.1 70000
DS06025_12E -FG B R 12 7.0 to 13.2 0.20 2.40 2500 0.387 13.65 2.16 0.085 20.6 70000
DS06025_12L -FG B R 12 7.0 to 13.2 0.30 3.60 3300 0.551 18.45 3.62 0.143 26.0 70000
DS06025_12L -FG B R 12 7.0 to 13.2 0.40 4.80 4000 0.673 23.76 5.21 0.205 31.5 70000
DS06025_12H -FG B R 12 7.0 to 13.2 0.60 7.20 5000 0.808 28.54 8.01 0.315 37.4 70000
* DS06025_12U -FG B R 12 7.0 to 13.2 0.70 8.40 6800 1.101 38.85 12.54 0.494 45.9 70000
0.54
12.6
0.48 .5
25 ±0
4
11.2
0.42 6800RPM
9.8 5000RPM
0.36 4000RPM
10(REF.)
8.4
AIR PRESSURE
3300RPM
310±10
0.30
7.0 2500RPM
50±0.3
0.24 2000RPM
57.5
5.6 Ø66
0.18
4.2
0.12
2.8
50 ±0 Ø4. 3 Ø4. 3
.3 ±0.3
0.06 1.4 60 ±0
.5
0.00 0.0
0.00 0.11 0.22 0.33 0.44 0.55 0.66 0.77 0.88 0.99 1.10 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 3.9 7.8 11.7 15.6 19.5 23.4 27.3 31.2 35.1 39.0
AIR FLOW
52
6 0 × 6 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #28 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 80.0g (2.82 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATB0625_2E -FG / RD B 12 7 to 13.2 0.11 1.32 4200 0.659 23.29 5.23 0.206 34.2 150000
DATB0625_2L -FG / RD B 12 7 to 13.2 0.15 1.80 5000 0.785 27.73 7.42 0.292 38.3 140000
DATB0625_2M -FG / RD B 12 7 to 13.2 0.22 0.64 6000 0.954 33.68 10.46 0.412 42.6 140000
DATB0625_2H -FG / RD B 12 7 to 13.2 0.33 3.96 6800 1.104 38.98 13.20 0.520 46.2 105000
DC axial fans
DATB0625_2U -FG / RD B 12 7 to 13.2 0.45 5.40 7400 1.203 42.49 16.00 0.63 48.9 105000
DATB0625_2S -FG / RD B 12 7 to 13.2 0.54 6.48 8200 1.324 46.76 19.40 0.764 50.6 70000
* DATB0625_2F -FG / RD B 12 7 to 13.2 0.72 8.64 9000 1.475 52.08 23.90 0.941 54.0 70000
27.5
1.00 25.0
±0.3
DC blower fans
0.90 22.5 25.4
9000RPM
0.80 20.0
8200RPM
0.70 17.5
AIR PRESSURE
7400RPM
0.60 15.0
50.0±0.3
6800RPM
10(REF.)
310±10
57.5
0.00 0.0
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 (M3/MIN)
(INCH-H2O)
(CFM)
AC fans
(MM-H2O)
0.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0 48.0 54.0
AIR FLOW
53
6 0 × 6 0 × 2 5 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATB0625_8E -FG / RD B 48 28 to 56 0.06 1.92 4200 0.659 23.29 5.23 0.206 34.2 150000
DATB0625_8L -FG / RD B 48 28 to 56 0.07 2.40 5000 0.785 27.73 7.42 0.292 38.3 140000
DATB0625_8M -FG / RD B 48 28 to 56 0.09 3.36 6000 0.954 33.68 10.46 0.412 42.6 140000
DATB0625_8H -FG / RD B 48 28 to 56 0.12 4.80 6800 1.104 38.98 13.20 0.520 46.2 105000
DATB0625_8U -FG / RD B 48 28 to 56 0.13 5.28 7400 1.203 42.49 16.00 0.63 48.9 105000
DATB0625_8S -FG / RD B 48 28 to 56 0.17 7.20 8200 1.324 46.76 19.40 0.764 50.6 70000
* DATB0625_8F -FG / RD B 48 28 to 56 0.21 9.12 9000 1.475 52.08 23.90 0.941 54.0 70000
27.5
1.00 25.0
0.90 22.5
±0.3
9000RPM 25.4
0.80 20.0
8200RPM
0.70 17.5
AIR PRESSURE
7400RPM
0.60 15.0
6800RPM
0.50 12.5
50.0±0.3
10(REF.)
310±10
6000RPM
57.5
(CFM)
(MM-H2O)
0.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0 48.0 54.0
AIR FLOW
54
DS SER IES
6 0 × 6 0 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 84g (2.96 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS06038_12X -FG/RD R 12 7.0 to 13.2 0.30 3.60 3500 0.553 19.54 3.81 0.150 27.3 50000
DS06038_12E -FG/RD R 12 7.0 to 13.2 0.40 4.80 4000 0.609 21.52 4.92 0.194 31.4 50000
DS06038_12L -FG/RD R 12 7.0 to 13.2 0.45 5.40 4500 0.70 24.72 6.12 0.241 36.6 50000
DS06038_12M -FG/RD R 12 7.0 to 13.2 0.50 6.00 5000 0.783 27.65 7.51 0.296 37.8 50000
DC axial fans
DS06038_12H -FG/RD R 12 7.0 to 13.2 0.70 8.40 5500 0.878 31.01 9.0 0.354 40.8 50000
DS06038_12U -FG/RD R 12 7.0 to 13.2 0.80 9.60 6000 0.973 34.37 10.88 0.428 44.5 50000
DS06038_12S -FG/RD R 12 7.0 to 13.2 1.00 12.00 7000 1.1179 39.48 14.48 0.570 48.8 50000
0.60
14.4
0.54 7000RPM
12.8 6000RPM
DC blower fans
0.48 05.
38± 4
11.2 5500RPM
0.42
5000RPM
9.6
0.36 4500RPM
AIR PRESSURE
8.0 4000RPM
0.30
310±10
□50±0.3
10(REF.)
3500RPM Ø67
□57.5
6.4 .5
0.24
0.18 4.8
0.12 3.2
Ø4.3
□50
±0 Ø4.3 ±0.3
□60 .3 ±0.3
0.06 1.6 ±0.5
0.00 0.0
0.00 0.11 0.22 0.33 0.44 0.55 0.66 0.77 0.88 0.99 1.10 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 4.0 8.0 12.0 16.0 20.0 24.0 28.0 32.0 36.0 40.0
AC fans
AIR FLOW
55
2B SER IES
6 0 × 6 0 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 116g (4.09 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
2B06038_12L -FG / RD B 12 7.0 to 13.2 0.6 7.2 8000 1.297 45.80 22.00 0.87 51.5 110000
2B06038_12M -FG / RD B 12 7.0 to 13.2 0.8 9.6 9000 1.471 51.95 27.60 1.09 54.0 90000
2B06038_12H -FG / RD B 12 7.0 to 13.2 0.96 11.52 10000 1.637 57.80 34.50 1.36 57.0 70000
2B06038_12U -FG / RD B 12 7.0 to 13.2 1.15 13.8 11000 1.786 63.06 40.10 1.579 59.5 70000
2B06038_12S -FG / RD B 12 7.0 to 13.2 1.5 18 12000 1.984 70.06 49.80 1.96 61.5 70000
* 2B06038_12G -FG / RD B 12 7.0 to 13.2 1.8 21.6 13500 2.050 72.41 60.60 2.386 64.6 70000
62.0
2.40
2.20 55.8
2.00
49.6
13500 RPM
±0.5 4
1.80
12000 RPM 38.0
43.4
1.60 11000 RPM
AIR PRESSURE
37.2
1.40
10000 RPM
10(REF.)
310±10
1.20 31.0
50.0±0.3
9000 RPM
Ø64
.0
58.0
0.80
18.6
0.60
Ø4.5
12.4 50.0 ±0.3 Ø4.5
±0.3 ±0.3
0.40 0
60.0
6.2 ±0.5
0.20 0
0.00 0.0
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
0.0 7.3 14.6 21.9 29.2 36.5 43.8 51.1 58.4 65.7 73.0 80.3
AIR FLOW
56
6 0 × 6 0 × 5 6 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 7 Blades inlet, 3 Blades outlet
* Rotational direction CCW view from front face
* Weight: 182g (6.42 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DFTA0656_2U -FG / RD B 12 7.0 to 13.2 1.60 19.20 9500 1.727 60.99 46.10 1.815 69.0 70000
DFTA0656_2S -FG / RD B 12 7.0 to 13.2 2.26 27.12 10500 1.945 68.68 57.30 2.256 71.0 70000
* DFTA0656_2F -FG / RD B 12 7.0 to 13.2 3.13 37.56 11500 2.164 76.42 68.50 2.697 72.5 70000
DC axial fans
75.0
2.80
±0.5
56.0 0.3 .3
67.5 23± 4±0
11500RPM 0 .3
2.45 33±
60.0
10500RPM .3
2.10 4±0
52.5
DC blower fans
AIR PRESSURE
9500RPM
1.75 45.0
50.0±0.3
37.5 Ø58
1.40 .0
30.0
1.05
22.5
0.70 Ø4.5
±0.3
15.0
Ø4.5
10(REF.)
310±10
50.0 ±0.3
0.35 ±0.3
7.5
60.0
±0.5
0.00 0.0
0.00 0.30 0.60 0.90 1.20 1.50 1.80 2.10 2.40 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
0.0 9.0 18.0 27.0 36.0 45.0 54.0 63.0 72.0 81.0
AC fans
AIR FLOW
57
6 0 × 6 0 × 7 6 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #26 or Equivalent
* Impeller: 7 Blades inlet, 5 Blades outlet
* Rotational direction CCW view from front face
* Weight: 253g (8.92 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DFTA0676_2U -FG/RD B 12 7.0 to 13.2 2.5 30 13300 2.137 75.49 66.10 2.602 70.5 70000
* DFTA0676_2S -FG/RD B 12 7.0 to 13.2 3.5 42 14200 2.404 84.91 77.30 3.043 71.5 70000
80.0
3.00 14200 RPM
70.0
±0.5 4
13300 RPM 76.0
2.50
60.0
2.00 50.0
Ø50.0
40.0 Ø64
Ø58.0
1.50
AIR PRESSURE
.0
30.0
1.00
310±10
20.0 Ø4.5
±0.3
Ø50
0.50 .0±0 Ø4.5
10.0 .3 ±0.3
Ø60
10(REF.)
.0±0
.5
0.00 0.0
0.00 0.50 1.00 1.50 2.00 2.50 3.00 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
58
DA SERIES
70×70×15 mm
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 45g (1.59 OZ)
Information
Operating Voltage Range
Acoustic Noise
Rated Voltage
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PART NO. SIGNAL B.T.S.R VDC VDC Amp Watt R.P.M. m3/min CFM mmH2O IN H2O dB-A hours
DA07015_12L -FG/RD B T R 12 7.0 to 13.2 0.30 3.60 3400 0.832 29.38 3.55 0.140 32.6 70000
DA07015_12M -FG/RD B T R 12 7.0 to 13.2 0.40 4.80 4100 0.962 33.96 5.19 0.204 38.3 70000
DA07015_12H -FG/RD B T R 12 7.0 to 13.2 0.50 6.00 4500 1.085 38.33 6.31 0.248 41.2 70000
DA07015_12U -FG/RD B T R 12 7.0 to 13.2 0.70 8.40 5400 1.275 45.01 8.90 0.350 46.1 70000
DC axial fans
12.0
0.45
5.
11.0 15±0
DC blower fans
0.40
10.0
6000RPM
0.35 9.0
5000RPM
8.0
0.30
4500RPM
7.0
AIR PRESSURE
0.25 3600RPM
310 ± 10
6.0
□ 60±0.3
3000RPM
10(REF.)
□ 63.5
0.15 4.0
3.0
0.10
2.0
0.05 □ 60 Ø4.3± Ø4.3±
1.0 ±0.3 0.3 0.3
0.00 0.0 □ 70
±0.5
0.00 0.15 0.30 0.45 0.60 0.75 0.90 1.05 1.20 1.35 1.50 (M3/MIN)
(CFM)
AC fans
(INCH-H2O)
(MM-H2O)
0.0 4.5 9.0 13.5 18.0 22.5 27.0 31.5 36.0 40.5 45.0 49.5
AIR FLOW
59
DS SER IES
7 0 × 7 0 × 1 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 45g (1.59 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS07015_12E -FG/RD B T R 12 7.0 to 13.2 0.20 2.40 3000 0.623 22.0 2.68 0.106 26.5 70000
DS07015_12L -FG/RD B T R 12 7.0 to 13.2 0.30 3.60 3600 0.739 26.12 3.56 0.140 30.9 70000
* DS07015_12M -FG/RD B T R 12 7.0 to 13.2 0.40 4.80 4500 0.621 32.54 5.56 0.219 38.1 70000
DS07015_12H -FG/RD B T R 12 7.0 to 13.2 0.50 6.00 5000 1.072 37.88 6.78 0.267 40.2 70000
DS07015_12U -FG/RD B T R 12 7.0 to 13.2 0.70 8.40 6000 1.247 44.03 9.33 0.367 45.4 70000
12.0
0.45
11.0
0.40 .5
10.0 15 ±0
6000RPM
0.35 9.0
5000RPM
8.0
0.30
4500RPM
7.0
AIR PRESSURE
0.25 3600RPM
3 10 ±10
6.0
61.5±0.3
0.20 3000RPM
5.0 Ø67.5
74
10(REF.)
0.15 4.0
3.0
0.10
2.0
61.5 Ø6.5
0.05 ±0.3 Ø4.3±X6.0 Ø4.3±
1.0 0.3 0.3
70 ±0
0.00
.5
0.0
0.00 0.15 0.30 0.45 0.60 0.75 0.90 1.05 1.20 1.35 1.50 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
0.0 4.5 9.0 13.5 18.0 22.5 27.0 31.5 36.0 40.5 45.0 49.5
AIR FLOW
60
DE SER IES
7 0 × 7 0 × 1 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 45g (1.59 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DE07015_12L -FG/RD B T R 12 7.0 to 13.2 0.30 3.60 3600 0.751 26.52 2.87 0.113 33.8 70000
DE07015_12M -FG/RD B T R 12 7.0 to 13.2 0.40 4.80 4100 03.914 32.26 3.71 0.146 36.9 70000
DE07015_12H -FG/RD B T R 12 7.0 to 13.2 0.50 6.00 4500 0.996 35.18 4.51 0.178 39.6 70000
* DE07015_12U -FG/RD B T R 12 7.0 to 13.2 0.70 8.40 5400 1.099 38.82 6.54 0.258 44.4 70000
DC axial fans
7.2
0.27
5400RPM
6.4
0.24 0.5
4500RPM 15.0 ±
DC blower fans
5.6
0.21
4100RPM
4.8
0.18
3600RPM
AIR PRESSURE
4.0
0.15
310±10
3.2
0.12
61.5±0.3
10(REF.)
74
Ø67.5
2.4
0.09
0.06 1.6
(CFM)
(MM-H2O)
0.0 3.9 7.8 11.7 15.6 19.5 23.4 27.3 31.2 35.1 39.0 42.9 46.8
AC fans
AIR FLOW
61
DA SER IES
7 0 × 7 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 64g (2.26 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA07020_12L -FG/RD B T R 12 5.0 to 13.2 0.20 2.40 3600 1.082 38.2 3.66 0.144 36.7 70000
* DA07020_12M -FG/RD B T R 12 5.0 to 13.2 0.30 3.60 4100 1.155 40.80 4.72 0.186 41.1 70000
DA07020_12H -FG/RD B T R 12 5.0 to 13.2 0.33 3.96 4500 1.240 43.78 5.79 0.228 43.3 70000
DA07020_12U -FG/RD B T R 12 5.0 to 13.2 0.70 8.40 5400 1.537 54.27 8.19 0.322 48.2 70000
0.36
9.0
0.32 8.0
.5
5400RPM 20±0
0.28 7.0
4500RPM
0.24 6.0
4100RPM
0.20
AIR PRESSURE
5.0
3600RPM
3 10 ±10
60±0.3
0.16
10(REF.)
4.0
67.5
Ø74
0.12 3.0
0.08 2.0
60±0.3 Ø6.5X
0.04
Ø4.3± 6.0 Ø4.3±
1.0 0.3 0.3
70±0.5
0.00 0.0
0.00 0.16 0.32 0.48 0.64 0.80 0.96 1.12 1.28 1.44 1.60 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 5.5 11.0 16.5 22.0 27.5 33.0 38.5 44.0 49.5 55.0
AIR FLOW
62
DV SER IES
7 0 × 7 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 65g (2.29 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DV07020_12E -FG/RD B 12 5.0 to 13.2 0.20 2.40 3600 0.673 23.76 4.88 0.192 33.1 70000
DV07020_12L -FG/RD B 12 5.0 to 13.2 0.30 3.60 4400 0.823 29.06 7.01 0.276 39.4 70000
DV07020_12M -FG/RD B 12 5.0 to 13.2 0.40 4.80 5200 1.059 37.39 9.30 0.366 43.2 70000
DV07020_12H -FG/RD B 12 5.0 to 13.2 0.50 6.00 6000 1.213 42.85 12.15 0.478 47.7 70000
DC axial fans
DV07020_12U -FG/RD B 12 5.0 to 13.2 0.70 8.40 6800 1.307 46.17 14.63 0.576 50.6 70000
16.0
0.60
5.
14.4
20±0
0.54 6800RPM
DC blower fans
12.8
0.48
6000RPM
11.2
0.42 5200RPM
9.6
0.36 4400RPM
AIR PRESSURE
310±10
8.0
□ 60±0.3
0.30
10(REF.)
3600RPM
□ 63.5
Ø77
6.4
0.24
0.18 4.8
0.12 3.2
Ø6.0
□ 60 Ø 4.3 X3.0 Ø4.3±
±0.3 ±0.3 0.3
0.06 1.6
□ 70
0.00 0.0 (M3/MIN) ±0.5
0.00 0.13 0.26 0.39 0.52 0.65 0.78 0.91 1.04 1.17 1.30
(INCH-H2O)
(MM-H2O)
(CFM)
AC fans
0.0 4.7 9.4 14.1 18.8 23.5 28.2 32.9 37.6 42.3 47.0
AIR FLOW
63
DY SER IES
7 0 × 7 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight :75g (2.645 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
F7025_12EX FG B 12 10.8 to 13.2 0.20 2.40 2800 0.721 25.46 3.49 0.137 27.9 70000
F7025_12LX FG B 12 10.8 to 13.2 0.25 3.00 3600 0.902 31.85 5.30 0.209 32.2 70000
F7025_12MX FG B 12 10.8 to 13.2 0.35 4.20 4200 1.077 38.01 7.58 0.298 38.8 70000
F7025_12HX FG B 12 10.8 to 13.2 0.70 8.40 5200 1.481 52.29 11.32 0.446 43.6 70000
13.0 .3
0.50 ±0.3 4±0
25.0
11.7 .3
0.45 4±0
10.4
0.40
0.35 9.1
AIR PRESSURE
0.30 7.8
5200RPM
10.0(REF.)
310 ±10
60.0±0.3
0.25 6.5
4200RPM
67.4
5.2
3600RPM
0.20
2800RPM
Ø78
0.15 3.9
0.10 2.6
Ø4.3
(CFM)
Ø6.5
64
DS SER IES
7 0 × 7 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 67g (2.36 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS07025_12L -FG/RD B R 12 5.0 to 13.2 0.20 2.40 2800 0.759 26.79 3.39 0.133 27.7 70000
DS07025_12L -FG/RD B R 12 5.0 to 13.2 0.30 3.50 3500 0.934 33.0 5.43 0.214 34.1 70000
DS07025_12M -FG/RD B R 12 5.0 to 13.2 0.40 4.80 4200 1.169 41.30 7.53 0.296 39.3 70000
DS07025_12H -FG/RD B R 12 5.0 to 13.2 0.50 6.00 4800 1.292 45.64 8.81 0.347 43.6 70000
DC axial fans
* DS07025_12U -FG/RD B R 12 5.0 to 13.2 0.70 8.40 5500 1.534 54.18 11.21 0.441 47.7 70000
DS07025_12S -RD/RD B 12 5.0 to 13.2 0.80 9.60 6300 1.430 64.62 14.42 0.568 50.8 70000
16.0
0.60 6300RPM .5
14.4
25±0 4
0.54 5500RPM
DC blower fans
12.8
0.48 4800RPM
11.2
0.42 4200RPM
9.6
0.36
310±10
3500RPM
AIR PRESSURE
8.0
10(REF.)
Ø76.5
60±0.3
0.30
2800RPM
67.5
6.4
0.24
0.18 4.8
0.12 3.2
60±0 Ø4.3± Ø4.3±
.3 0.3 0.3
70±0
0.06 1.6 .5
0.00 0.0
0.00 0.18 0.36 0.54 0.72 0.90 1.08 1.26 1.44 1.62 1.80 1.98 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 6.5 13.0 19.5 26.0 32.5 39.0 45.5 52.0 58.5 65.0 71.5
AC fans
AIR FLOW
65
DS SER IES
8 0 × 8 0 × 1 5 m m 1 2 v ,2 4 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS08015_12L -FG/RD BT 12 5.0 to 13.2 0.42 5.04 2500 0.676 23.86 2.57 0.101 27.2 70000
* DS08015_12M -FG/RD BT 12 5.0 to 13.2 0.48 5.76 3400 0.950 33.54 4.56 0.180 35.1 70000
DS08015_12H -FG/RD BT 12 5.0 to 13.2 0.50 6.00 4000 1.083 38.26 6.24 0.246 39.8 70000
DS08015_12U -FG/RD BT 12 5.0 to 13.2 0.60 7.20 5000 1.398 49.35 9.27 0.365 45.5 70000
DS08015_24M -FG/RD B 24 10.0 to 26.4 0.38 9.12 3100 0.840 29.68 3.32 0.131 31.4 70000
0.44 11.0
0.40
9.9
5000RPM 0.5
0.36
15.0±
8.8
0.32 4000RPM
7.7
0.28
3400RPM
6.6
AIR PRESSURE
0.24
31 00RPM
310±10
5.5
0.20
71.5±0.3
2500RPM Ø83.5
10(REF.)
77.5
4.4
0.16
3.3
0.12
0.08 2.2
Ø6.3X
0.04 1.1 71.5± Ø4.3±6.0 Ø4.3±
0.3 0.3
0.3
0.00 0.0 80±0
0.00 0.14 0.28 0.42 0.56 0.70 0.84 0.98 1.12 1.26 1.40 1.54 1.68 (M3/MIN) .5
(CFM)
(INCH-H2O)
(MM-H2O)
0.0 5.1 10.2 15.3 20.4 25.5 30.6 35.7 40.8 45.9 51.0
AIR FLOW
66
DA SER IES
8 0 × 8 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 77g (2.72 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA08020_12E -FG/RD BT R 12 5.0 to 13.2 0.15 1.80 2800 0.964 34.05 3.17 0.125 31.4 70000
DA08020_12L -FG/RD BT R 12 5.0 to 13.2 0.21 2.52 3300 1.226 43.30 4.30 0.169 35.5 70000
DA08020_12M -FG/RD BT R 12 5.0 to 13.2 0.28 3.36 3800 1.389 49.06 5.67 0.223 40.3 70000
DA08020_12H -FG/RD BT R 12 5.0 to 13.2 0.35 4.20 4300 1.557 54.98 7.07 0.278 43.9 70000
DC axial fans
* DA08020_12U -FG/RD BT R 12 5.0 to 13.2 0.46 5.52 4800 1.750 61.80 8.79 0.346 47.6 70000
0.36 9.0
0.32 8.0 .5
20±0
0.28 4800RPM
DC blower fans
7.0
4300RPM
0.24 6.0
3800RPM
3300RPM
3 10 ±10
0.20
AIR PRESSURE
5.0 Ø83.5
71.5 ±0.3
2800RPM
10(REF)
0.16
77.5
4.0
0.12 3.0
0.00 0.0
0.00 0.18 0.36 0.54 0.72 0.90 1.08 1.26 1.44 1.62 1.80 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 6.2 12.4 18.6 24.8 31.0 37.2 43.4 49.6 55.8 62.0
AC fans
AIR FLOW
67
DS SER IES
8 0 × 8 0 × 2 0 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 70g (2.47 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS08020_12E -FG/RD BT R 12 5.0 to 13.2 0.20 2.40 2800 1.018 35.95 3.44 0.135 32.2 70000
DS08020_12L -FG/RD BT R 12 5.0 to 13.2 0.30 3.60 3300 1.114 39.33 4.78 0.188 37.2 70000
* DS08020_12M -FG/RD BT R 12 5.0 to 13.2 0.40 4.80 3600 1.233 43.53 5.57 0.219 40.1 70000
DS08020_12H -FG/RD BT R 12 5.0 to 13.2 0.50 6.00 4200 1.448 51.14 7.36 0.290 44.2 70000
DS08020_12U -FG/RD BT 12 5.0 to 13.2 0.60 7.20 4900 1.694 59.82 9.85 0.388 48.3 70000
0.44 11.0
0.40
9.9
4900RPM .5
0.36
8.8
20±0 4
0.32 4200RPM
7.7
3600RPM
AIR PRESSURE
0.28
6.6
0.24 3300RPM
5.5
0.20 2800RPM
310±10
4.4
71.5±0.3
0.16 Ø83.5
77.5
10(REF.)
3.3
0.12
0.08 2.2
0.04 1.1
(MM-H2O)
0.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0 48.0 54.0 60.0
AIR FLOW
68
8 0 × 8 0 × 2 5 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTA0825_2M -FG / RD B 12 7.0 to 13.2 0.19 2.28 3500 1.395 49.27 6.06 0.239 42.0 130000
DBTA0825_2H -FG / RD B 12 7.0 to 13.2 0.25 3.00 4000 1.582 55.86 7.76 0.306 44.5 130000
* DBTA0825_2U -FG / RD B 12 7.0 to 13.2 0.34 4.08 4500 1.808 63.85 10.00 0.394 48.0 130000
DBTA0825_8M -FG / RD B 48 36.0 to 56.0 0.05 2.40 3500 1.395 49.27 6.06 0.239 42.0 130000
DC axial fans
DBTA0825_8H -FG / RD B 48 36.0 to 56.0 0.07 3.36 4000 1.582 55.86 7.76 0.306 44.5 130000
* DBTA0825_8U -FG / RD B 48 36.0 to 56.0 0.10 4.80 4500 1.808 63.85 10.00 0.394 48.0 130000
12.0
0.45
±0.5
25.4 4
0.40 10.0
DC blower fans
0.35
8.0
0.30 4500 RPM
AIR PRESSURE
4000 RPM
310 ±10
0.25
6.0
71. 5±0. 3
10(REF.)
3500 RPM Ø 88
.6
77.2
0.20
0.15 4.0
0.10
2.0
71.5
±0.3
0.05 Ø4.5
80.0 ±0.3
±0.5
0.00 0.0 (M3/MIN)
Ø4.5±0.3
AIR FLOW
69
DL SER IES
8 0 × 8 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 80g (2.83 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DL08025_12L -FG/RD R 12 4.0 to 13.2 0.15 1.80 2050 0.672 23.73 2.02 0.080 22.4 50000
DL08025_12M -FG/RD R 12 4.0 to 13.2 0.25 3.00 2450 0.808 28.55 2.74 0.108 26.7 50000
DL08025_12H -FG/RD R 12 4.0 to 13.2 0.35 4.20 3000 1.068 37.70 4.15 0.163 32.3 50000
* DL08025_12U -FG/RD R 12 4.0 to 13.2 0.50 6.00 4500 1.542 54.47 8.48 0.334 43.7 50000
11.0 .5
25 ±0
0.40 4
10.0
0.36 9.0
0.32
4500RPM
8.0
0.28 7.0
3000RPM
310 ±10
AIR PRESSURE
0.24
71.5±0.3
6.0
2450RPM Ø83.5
10(REF.)
77.5
0.20 5.0
2050RPM
0.16 4.0
0.12 3.0
71.5 Ø4.3
0.08 2.0 ±0.3 ±0.3
Ø4.3±
0.3
80 ±0
0.04 1.0 .5
0.00 0.0
0.00 0.16 0.32 0.48 0.64 0.80 0.96 1.12 1.28 1.44 1.60 1.76 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
0.0 5.5 11.0 16.5 22.0 27.5 33.0 38.5 44.0 49.5 55.0 60.5
AIR FLOW
70
DS SER IES
8 0 × 8 0 × 2 5 m m 1 2 v ,2 4 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS08025_12L -FG/RD B T R 12 7.0 to 13.2 0.15 1.80 2050 0.831 29.34 2.10 0.083 24.9 70000
DS08025_12M -FG/RD B T R 12 7.0 to 13.2 0.23 2.76 2450 1.016 35.89 2.88 0.113 29.6 70000
DS08025_12H -FG/RD B T R 12 7.0 to 13.2 0.30 3.60 3000 1.246 44.02 4.43 0.174 34.5 70000
* DS08025_12U -FG/RD B T R 12 7.0 to 13.2 0.70 8.40 4500 1.824 64.44 9.73 0.383 46.0 70000
DC axial fans
DS08025_24H -FG/RD B 24 10.0 to 26.4 7.20 7.20 3000 1.246 44.02 4.43 0.174 34.5 70000
0.40
10.0
0.36 9.0
0.5
25.4 ±
DC blower fans
0.32 8.0
4
4500RPM
0.28 7.0
3000RPM
0.24 6.0
2450RPM
0.20 5.0
310 ±10
71.5±0.3
2050RPM
AIR PRESSURE
Ø83.5
77.5
0.16 4.0
10(REF.)
0.12 3.0
0.08 2.0
Ø4.5
0.04 71.5± Ø4.5 ±0.3
1.0 0.3 ±0.3
(CFM)
(MM-H2O)
AC fans
0.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0 48.0 54.0 60.0 66.0
AIR FLOW
71
8 0 × 8 0 × 3 2 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 120g (4.23 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DASA0832_12E -FG/RD B 12 4.0 to 13.2 0.30 3.60 3000 1.081 38.17 5.02 0.198 30.6 70000
DASA0832_12L -FG/RD B 12 4.0 to 13.2 0.40 4.80 4000 1.406 49.65 8.82 0.347 39.2 70000
DASA0832_12M -FG/RD B 12 4.0 to 13.2 0.70 8.40 4800 1.710 60.40 11.38 0.448 44.9 70000
DASA0832_12H -FG/RD B 12 4.0 to 13.2 0.80 9.60 5500 1.956 69.09 15.53 0.611 48.4 70000
DASA0832_12U -FG/RD B 12 4.0 to 13.2 1.00 12.0 6800 2.454 86.67 22.57 0.889 53.9 70000
21.0
0.80
18.9
0.72 0.5
6000RPM 32± 4
16.8
0.64
5000RPM
14.7
0.56
AIR PRESSURE
12.6
0.48 4500RPM
10.5
310±10
0.40
3000RPM
□71.5±0.3
□77.5
8.4 Ø83.5
10(REF.)
0.32
0.24 6.3
0.16 4.2
Ø4.5
0.08 2.1 ±0.3
□71
.5±0.3 Ø4.5±
0.3
0.00 0.0 □80
±0.5
0.00 0.22 0.44 0.66 0.88 1.10 1.32 1.54 1.76 1.98 2.20 2.42 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0
AIR FLOW
72
8 0 × 8 0 × 3 8 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA0838_2H -FG/RD B 12 7 to 13.2 0.67 8.0 5700 2.247 79.36 16.80 0.661 49.0 130000
DATA0838_2U -FG/RD B 12 7 to 13.2 0.85 10.2 6300 2.496 88.16 20.40 0.803 52.0 130000
* DATA0838_2S -FG/RD B 12 7 to 13.2 1.22 14.6 6800 2.709 95.67 23.90 0.941 54.5 110000
DATA0838_2F -FG/RD B 12 7 to 13.2 1.7 20.4 7800 3.093 109.3 31.00 1.220 57.5 110000
DC axial fans
DATA0838_8H -FG/RD B 48 36 to 60 0.18 8.6 5700 2.247 79.36 16.80 0.661 49.0 130000
DATA0838_8U -FG/RD B 48 36 to 60 0.22 10.6 6300 2.496 88.16 20.40 0.803 52.0 130000
* DATA0838_8S -FG/RD B 48 36 to 60 0.32 15.4 6800 2.709 95.67 23.90 0.941 54.5 110000
36.3
1.30 33.0
7800RPM
±0.3
DC blower fans
1.17 29.7 38.0 4
6800RPM
1.04 26.4
6300RPM
0.91 23.1
5700RPM
10(REF.)
AIR PRESSURE
310±10
0.78 19.8
76.80
71.5
0.65 16.5
Ø90
.0
0.52 13.2
0.39 9.9
0.26 6.6
0.00 0.31 0.62 0.93 1.24 1.55 1.86 2.17 2.48 2.79 3.10 3.41 3.72 (M3/MIN)
AC fans
(INCH-H2O)
(MM-H2O)
(CFM)
0.0 11.0 22.0 33.0 44.0 55.0 66.0 77.0 88.0 99.0 110.0 121.0
AIR FLOW
73
2B SER IES
8 0 × 8 0 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #24 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 190g (6.7 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
2B08038_12E -FG/RD B 12 7 to 13.2 0.34 4.08 4000 1.58 55.79 9.88 0.39 44.3 130000
2B08038_12L -FG/RD B 12 7 to 13.2 0.58 6.69 5000 2.00 70.64 16.0 0.63 52.3 130000
2B08038_12M -FG/RD B 12 7 to 13.2 0.92 11.04 6000 2.43 85.93 23.0 0.91 55.9 110000
2B08038_12H -FG/RD B 12 7 to 13.2 1.42 17.04 7000 2.86 101.11 31.9 1.26 60.4 110000
2B08038_12U -FG/RD B 12 7 to 13.2 2.2 26.4 8000 3.29 116.46 41.3 1.62 62.8 110000
* 2B08038_12S -FG/RD B 12 7 to 13.2 3.2 38.4 9000 3.67 129.46 55.1 2.17 65.5 100000
57.0
2.20
51.3 9000RPM
1.98
45.6 8000RPM
1.76 ±0.3 4
38.0
39.9 7000RPM
1.54
10(REF.)
310 ±10
28.5 5000RPM
71.5±0.3
1.10
77.2
0.66 17.1
0.44 11.4
71.5 Ø4.5
±0.3 ±0.3
Ø4.5
±0.3
0.22 5.7 80.0
±0.5
0.00 0.0
0.00 0.74 1.48 2.22 2.96 3.70 4.07 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
74
2B SER IES
8 0 × 8 0 × 3 8 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
2B08038_48E -FG/RD B 48 28 to 56 0.09 4.32 4000 1.58 55.79 9.88 0.39 44.3 130000
2B08038_48L -FG/RD B 48 28 to 56 0.14 6.72 5000 2.00 70.64 16.0 0.63 52.3 130000
2B08038_48M -FG/RD B 48 28 to 56 0.22 10.56 6000 2.43 85.93 23.0 0.91 55.9 110000
2B08038_48H -FG/RD B 48 28 to 56 0.34 16.32 7000 2.86 101.11 31.9 1.26 60.4 110000
DC axial fans
2B08038_48U -FG/RD B 48 28 to 56 0.48 23.04 8000 3.29 116.46 41.3 1.62 62.8 110000
* 2B08038_48S -FG/RD B 48 28 to 56 0.75 36 9000 3.67 129.46 55.1 2.17 65.5 100000
57.0
2.20
51.3 9000RPM
1.98
45.6 8000RPM
1.76 ±0.3 4
38.0
7000RPM
DC blower fans
1.54 39.9
10(REF.)
310 ±10
28.5 5000RPM
71.5±0.3
1.10
77.2
0.66 17.1
0.44 11.4
71.5 Ø4.5
±0.3 ±0.3
Ø4.5
±0.3
0.22 5.7 80.0
±0.5
0.00 0.0
0.00 0.74 1.48 2.22 2.96 3.70 4.07 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
75
8 0 × 8 0 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #22 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 210g (7.41OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DYTB0838_2S -FG/RD B 12 7 to 13.2 1.85 22.2 11000 3.416 120.65 58.8 2.315 64.0 70000
66.0
2.40 60.0
2.16 54.0
11000 RPM
1.92 48.0
1.68 42.0
1.44
AIR PRESSURE
36.0
1.20 30.0
0.96 24.0
0.72 18.0
0.48 12.0
0.24 6.0
0.00 0.0
0.00 0.68 1.36 2.04 2.72 3.40 4.08 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
76
9 2 × 9 2 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 132g (4.65 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DAKA0925_2E FG B 12 5 to 13.2 0.3 3.6 2000 1.204 42.51 2.53 0.100 30.02 70000
DAKA0925_2L FG B 12 5 to 13.2 0.5 6 2600 1.617 57.07 4.46 0.176 37.77 70000
DAKA0925_2M FG B 12 5 to 13.2 0.8 9.6 3200 2.071 73.10 6.86 0.270 43.33 70000
DAKA0925_2H FG B 12 5 to 13.2 1.2 14.4 3800 2.484 87.66 9.93 0.391 48.66 70000
DC axial fans
DAKA0925_2U FG B 12 5 to 13.2 2.0 24 4600 3.019 106.55 14.10 0.551 54.12 70000
17.6
0.66 . 3
4±0
16.0 25.
0.60 .3
4±0
14.4
0.54
12.8
4600RPM
DC blower fans
0.48
11.2 3800RPM
310±10
0.42
3200RPM
□ 85.5±0.3
9.6
0.36
Ø 88
2600RPM .4
8.0
0.30
2000RPM
AIR PRESSURE
6.4
0.24
0.18 4.8
0.12 3.2
□8
5.5± Ø 4.2
0.3
0.06 1.6 □9
2.0±
0.3
0.00 0.0
0.00 0.30 0.60 0.90 1.20 1.50 1.80 2.10 2.40 2.70 3.00 3.30 3.60 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
0.0 10.7 21.4 32.1 42.8 53.5 64.2 74.9 85.6 96.3 107.0
AIR FLOW
77
DL SER IES
9 2 × 9 2 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 90g (3.17 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DL09225_12E -FG/RD R 12 7 to 13.2 0.15 1.80 2100 1.073 37.90 2.23 0.088 26.2 70000
DL09225_12M -FG/RD R 12 7 to 13.2 0.25 3.00 2800 0.405 49.60 3.71 0.146 34.6 70000
DL09225_12H -FG/RD R 12 7 to 13.2 0.35 4.20 3300 1.696 59.91 5.01 0.197 39.8 70000
DL09225_12U -FG/RD R 12 7 to 13.2 0.50 6.00 3800 2.005 70.82 6.05 0.238 43.7 70000
7.2
0.27
6.4
.5
0.24 25±0 4
5.6
0.21
3800RPM
4.8
0.18
AIR PRESSURE
3300RPM
4.0
0.15
310±10
2800RPM
□ 82.5±0.3
3.2
0.12
10(REF.)
□ 89
0.06 1.6
(CFM)
(MM-H2O)
0.0 7.1 14.2 21.3 28.4 35.5 42.6 49.7 56.8 63.9 71.0 78.1
AIR FLOW
78
DS SERIES
92×92×25 mm
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 90g (3.170 OZ)
Information
Operating Voltage Range
Acoustic Noise
Rated Voltage
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PART NO. SIGNAL B.T.S.R VDC VDC Amp Watt R.P.M. m3/min CFM mmH2O IN H2O dB-A hours
DS09225_12E -FG/RD BT R 12 7.0 to 13.2 0.15 1.8 1800 0.926 32.71 1.78 0.070 23.6 70000
DS09225_12L -FG/RD BT R 12 7.0 to 13.2 0.20 2.4 2100 1.079 38.11 2.39 0.094 26.6 70000
DS09225_12M -FG/RD BT R 12 7.0 to 13.2 0.35 4.2 2800 1.389 49.07 4.22 0.166 36.2 70000
DS09225_12H -FG/RD BT R 12 7.0 to 13.2 0.5 6.0 3800 1.983 67.44 7.00 0.276 44.1 70000
DC axial fans
DS09225_12U -FG/RD BT R 12 7.0 to 13.2 0.7 8.4 4500 2.250 79.47 10.03 0.395 49.6 70000
DC blower fans
10.8
0.40
. 5
9.6 25±0
4
0.35 4500RPM
8.4
0.30
3800RPM
7.2
2800RPM
0.25
AIR PRESSURE
6.0
2100RPM
0.20
310±10
4.8
□ 82.5±0.3
1800RPM
□ 89
10(REF.)
0.15
3.6
Ø100
0.10 2.4
0.05 1.2
(CFM)
(MM-H2O)
AC fans
0.0 8.0 16.0 24.0 32.0 40.0 48.0 56.0 64.0 72.0 80.0 88.0
AIR FLOW
79
9 2 × 9 2 × 2 5 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DYTB0925_48U -FG/RD B 48 36 to 26 0.14 6.72 4300 2.288 80.8 10.7 0.409 49.0 70000
±0.3 ) 0.3
4.0± 0.012)
12.1 25.0 ±0.012
9 8 4 5 7 ±
(0 . (0.1
0.44 11.0 0.3 )
4.0± 0.012
0.40 . 1 5 7±
9.9 (0
4300RPM
0.36
8.8
10.0(ref.)
310±10 0.39(ref.)
0.32
7.7
(12.20±0.39)
0.28
AIR PRESSURE
6.6
0.24
5.5
(3.24)
82.5
(3.50)
89.0
0.20
Ø10
0.16
4.4 (Ø3 0.0
.937
)
3.3
0.12
0.08 2.2
0.04 1.1
82 4-Ø
0.00 0.0 (3.2 .5±0.3 (0.1 4.3
4±0 4-
0.00 0.23 0.46 0.69 0.92 1.15 1.38 1.61 1.84 2.07 2.30 2.53 (M3/MIN) .012
) (0.1Ø4.3±0 69)
92.0 69± .3
(INCH-H2O)
0.01
(MM-H2O)
(CFM) (3.6 ±
2±0 0.5 2)
.02)
0.0 8.1 16.2 24.3 32.4 40.5 48.6 56.7 64.8 72.9 81.0 89.1
AIR FLOW
80
9 2 × 9 2 × 3 8 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DCTA0938_2M -FG/RD B 12 7 to 13.2 0.68 8.16 5700 2.544 89.83 18.66 0.735 53.1 140000
DCTA0938_2H -FG/RD B 12 7 to 13.2 1.08 13.0 7000 3.163 111.71 28.47 1.121 58.7 130000
* DCTA0938_2U -FG/RD B 12 7 to 13.2 1.60 19.2 8300 3.671 129.64 39.28 1.546 62.8 130000
DCTA0938_8M -FG/RD B 48 36.0 to 56.0 0.18 8.64 5700 2.544 89.83 18.66 0.735 53.1 140000
DC axial fans
DCTA0938_8H -FG/RD B 48 36.0 to 56.0 0.25 12.0 7000 3.163 111.71 28.47 1.121 58.7 130000
* DCTA0938_8U -FG/RD B 48 36.0 to 56.0 0.37 17.76 8300 3.671 129.64 39.28 1.546 62.8 130000
42.0
1.60 8300 RPM
7000 RPM
1.44
35.0 5700 RPM
1.28 ±0.5 4
38.0
1.12 28.0
0.80
310 ±10
10(REF.)
82.5
0.64
89
14.0 Ø99
0.48
0.32
7.0 82.5
±0.3 Ø4.5
92.0 Ø4.5 ±0.3
±0.5 ±0.3
0.16
0.00 0.0
0.00 0.74 1.48 2.22 2.96 3.70 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
AC fans
81
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DESA0938_12X -FG/RD BT R 12 5.0 to 13.2 0.30 3.60 2500 1.286 45.38 4.71 0.185 30.9 70000
DESA0938_12E -FG/RD BT R 12 5.0 to 13.2 0.38 4.56 3000 1.550 54.73 6.43 0.253 36.0 70000
DESA0938_12L -FG/RD BT R 12 5.0 to 13.2 0.53 6.36 3500 1.836 64.80 8.65 0.341 40.8 70000
* DESA0938_12M -FG/RD BT R 12 5.0 to 13.2 0.75 9.00 4000 2.141 75.56 11.75 0.463 44.8 70000
DESA0938_12H -FG/RD BT R 12 5.0 to 13.2 0.90 10.80 5000 2.626 92.69 15.53 0.611 51.2 70000
17.0
0.63
15.3
.5
0.56 25±0 4
13.6
0.49
11.9
0.42
10.2
AIR PRESSURE
0.35
5000RPM
310±10
8.5
82.5±0.3
4000RPM
10(REF.)
89
0.28
6.8
3500RPM Ø100
3000RPM
0.21 5.1 2500RPM
0.14 3.4
82.5 Ø4.3±
±0.3 Ø4.3± 0.3
92± 0.3
0.07 1.7 0.5
0.00 0.0
0.00 0.26 0.52 0.78 1.04 1.30 1.56 1.82 2.08 2.34 2.60 2.86 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
0.0 9.3 18.6 27.9 37.2 46.5 55.8 65.1 74.4 83.7 93.0
AIR FLOW
82
2B SER IES
9 2 × 9 2 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 270g (9.52 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
2B09238_12E -FG/RD B 12 7.0 to 13.2 0.22 2.64 3000 1.707 60.28 7.26 0.286 40.0 140000
2B09238_12L -FG/RD B 12 7.0 to 13.2 0.41 4.92 4000 2.295 81.05 12.6 0.496 47.2 140000
2B09238_12M -FG/RD B 12 7.0 to 13.2 0.7 8.4 5000 2.869 101.32 18.6 0.732 54.1 130000
2B09238_12H -FG/RD B 12 7.0 to 13.2 1.25 15.0 6000 3.496 123.46 27.8 1.095 58.6 130000
DC axial fans
2B09238_12U -FG/RD B 12 7.0 to 13.2 2.0 24.0 7000 4.150 146.57 37.9 1.492 62.4 130000
120000
* 2B09238_12S -FG/RD B 12 7.0 to 13.2 3.1 37.2 8000 4.654 164.34 46.8 1.843 65.8
48.0
1.80
8000 RPM
DC blower fans
42.0 7000 RPM
1.60 ±0.5 4
38.0
6000 RPM
1.40 36.0 5000 RPM
AIR PRESSURE
1.00
24.0
310±10
□ 82.5±0.3
0.80
□ 89.0
18.0
0.60 Ø10
3
12.0
0.40
0.20 6.0
□8 Ø4.5
0.00 0.0 2.5± Ø4.5 ±0.3
0.3 ±0.3
0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 (M /MIN) 3 □9
2.0±
0.5
(INCH-H2O)
(CFM)
(MM-H2O)
AC fans
83
2B SER IES
9 2 × 9 2 × 3 8 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
2B09238_48E -FG/RD B 48 28 to 56 0.08 3.84 3000 1.707 60.28 7.26 0.286 40.0 140000
2B09238_48L -FG/RD B 48 28 to 56 0.12 5.76 4000 2.295 81.05 12.6 0.496 47.2 140000
2B09238_48M -FG/RD B 48 28 to 56 0.2 9.6 5000 2.869 101.32 18.6 0.732 54.1 130000
2B09238_48H -FG/RD B 48 28 to 56 0.3 14.4 6000 3.496 123.46 27.8 1.095 58.6 130000
2B09238_48U -FG/RD B 48 28 to 56 0.47 22.56 7000 4.150 146.57 37.9 1.492 62.4 130000
2B09238_48S -FG/RD B 48 28 to 56 0.78 37.44 8000 4.654 164.34 46.8 1.843 65.8 120000
*
48.0
1.80
8000 RPM
42.0 7000 RPM
1.60 ±0.5 4
38.0
6000 RPM
1.40 36.0 5000 RPM
AIR PRESSURE
1.00
24.0
310±10
□ 82.5±0.3
0.80
□ 89.0
18.0
0.60 Ø10
3
12.0
0.40
0.20 6.0
□8 Ø4.5
0.00 0.0 2.5± Ø4.5 ±0.3
0.3 ±0.3
0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 (M3/MIN) □9
2.0±
0.5
(INCH-H2O)
(CFM)
(MM-H2O)
84
1 2 0 × 1 2 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 230g (8.11 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DATA1225_2X -FG/RD B 12 7 to 13.2 0.18 2.16 1900 1.657 58.51 3.40 0.134 31.5 157500
DATA1225_2E -FG/RD B 12 7 to 13.2 0.22 2.64 2200 1.898 67.04 4.39 0.173 34.5 145000
DATA1225_2L -FG/RD B 12 7 to 13.2 0.27 3.24 2500 2.130 75.22 5.41 0.213 39.5 135000
DATA1225_2M -FG/RD B 12 7 to 13.2 0.32 3.84 2800 2.416 85.31 6.72 0.265 41.5 135000
DC axial fans
* DATA1225_2H -FG/RD B 12 7 to 13.2 0.41 4.92 3100 2.727 96.31 8.36 0.329 43.5 120000
* DATA1225_2U -FG/RD B 12 7 to 13.2 0.47 5.64 3400 2.983 105.35 10.19 0.401 46.5 120000
* DATA1225_2S -FG/RD B 12 7 to 13.2 0.58 6.96 3700 3.230 114.08 11.71 0.462 49.0 120000
* DATA1225_2F -FG/RD B 12 7 to 13.2 0.70 8.40 4000 3.483 123.00 13.40 0.528 51.0 120000
DATA1225_2G -FG/RD B 12 7 to 13.2 0.85 10.20 4400 3.914 138.24 16.00 0.630 52.5 110000
0.70 18.0
DC blower fans
16.0
0.60 4400 RPM ±0.5
25.4 5
14.0 4000 RPM
0.50 3700 RPM
12.0
3400 RPM
AIR PRESSURE
8.0
□ 105.0±0.3
0.30
2500 RPM
□ 116.4
10(REF.)
(MM-H2O)
AC fans
85
1 2 0 × 1 2 0 × 2 5 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DATA1225_8X -FG/RD B 48 28 to 56 0.06 2.88 1900 1.657 58.51 3.40 0.134 31.5 157500
DATA1225_8E -FG/RD B 48 28 to 56 0.07 3.36 2200 1.898 67.04 4.39 0.173 34.5 145000
DATA1225_8L -FG/RD B 48 28 to 56 0.08 3.84 2500 2.130 75.22 5.41 0.213 39.5 135000
DATA1225_8M -FG/RD B 48 28 to 56 0.09 4.32 2800 2.416 85.31 6.72 0.265 41.5 135000
* DATA1225_8H -FG/RD B 48 28 to 56 0.11 5.28 3100 2.727 96.31 8.36 0.329 43.5 120000
* DATA1225_8U -FG/RD B 48 28 to 56 0.13 3.24 3400 2.983 105.35 10.19 0.401 46.5 120000
* DATA1225_8S -FG/RD B 48 28 to 56 0.15 7.20 3700 3.230 114.08 11.71 0.462 49.0 120000
* DATA1225_8F -FG/RD B 48 28 to 56 0.18 8.64 4000 3.483 123.00 13.40 0.528 51.0 120000
DATA1225_8G -FG/RD B 48 28 to 56 0.22 10.56 4400 3.914 138.24 16.00 0.630 52.5 110000
0.70 18.0
16.0
0.60 4400 RPM ±0.5
25.4 5
14.0 4000 RPM
0.50 3700 RPM
12.0
3400 RPM
AIR PRESSURE
8.0
□ 105.0±0.3
0.30
2500 RPM
□ 116.4
10(REF.)
(MM-H2O)
86
1 2 0 × 1 2 0 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 9 Blades
* Rotational direction CCW view from front face
* Weight: 250g (8.82 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTA1225_2L -FG/RD B 12 7.0 to 13.2 0.54 6.48 3100 3.069 108.38 8.05 0.317 49.0 120000
* DBTA1225_2M -FG/RD B 12 7.0 to 13.2 0.62 7.44 3400 3.340 117.96 9.50 0.374 51.5 120000
* DBTA1225_2H -FG/RD B 12 7.0 to 13.2 0.71 8.52 3700 3.682 130.04 11.38 0.448 54.0 120000
* DBTA1225_2U -FG/RD B 12 7.0 to 13.2 0.84 10.08 4000 3.985 140.75 13.51 0.532 55.5 120000
DC axial fans
* DBTA1225_2S -FG/RD B 12 7.0 to 13.2 1.19 14.28 4500 4.549 160.66 17.37 0.684 58.5 110000
20.0
0.70 18.0
±0.5
25.4 5
DC blower fans
16.0
0.60
4500 RPM
14.0
4000 RPM
0.50
12.0 3700 RPM
10(REF.)
3400 RPM
AIR PRESSURE
0.40 10.0
3100 RPM
□ 105±0.3
310±10
□ 116
8.0
0.30 Ø128
.0
6.0
0.20
4.0
0.10 □10
2.0 5.0± Ø4.5 Ø4.5
0.3 ±0.3 ±0.3
□12
0.0±
0.00 0.0
0.5
0.00 1.00 2.00 3.00 4.00 5.00 6.00
AC fans
(INCH-H2O)
(M3/MIN)
(MM-H2O)
87
1 2 0 × 1 2 0 × 2 5 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTA1225_8L -FG/RD B 48 36.0 to 56.0 0.14 6.72 3100 3.069 108.38 8.05 0.317 49.0 120000
* DBTA1225_8M -FG/RD B 48 36.0 to 56.0 0.16 7.68 3400 3.340 117.96 9.50 0.374 51.5 120000
* DBTA1225_8H -FG/RD B 48 36.0 to 56.0 0.19 9.12 3700 3.682 130.04 11.38 0.448 54.0 120000
* DBTA1225_8U -FG/RD B 48 36.0 to 56.0 0.24 11.52 4000 3.985 140.75 13.51 0.532 55.5 120000
* DBTA1225_8S -FG/RD B 48 36.0 to 56.0 0.32 15.36 4500 4.549 160.66 17.37 0.684 58.5 110000
20.0
0.70 18.0
±0.5
25.4 5
16.0
0.60
4500 RPM
14.0
4000 RPM
0.50
12.0 3700 RPM
10(REF.)
3400 RPM
AIR PRESSURE
0.40 10.0
3100 RPM
□ 105±0.3
310±10
□ 116
8.0
0.30 Ø128
.0
6.0
0.20
4.0
0.10 □10
2.0 5.0± Ø4.5 Ø4.5
0.3 ±0.3 ±0.3
□12
0.0±
0.00 0.0
0.5
0.00 1.00 2.00 3.00 4.00 5.00 6.00
(INCH-H2O)
(M3/MIN)
(MM-H2O)
88
DS SER IES
1 2 0 × 1 2 0 × 2 5 m m 1 2 v ,2 4 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DS12025_12E -FG/RD B R 12 7.0 to 13.2 0.20 2.40 2100 1.916 67.68 4.28 0.169 34.8 70000
DS12025_12L -FG/RD B R 12 7.0 to 13.2 0.30 3.60 2500 2.186 77.19 5.82 0.229 38.5 70000
DS12025_12M -FG/RD B R 12 7.0 to 13.2 0.48 5.76 2800 2.454 86.67 7.08 0.279 41.7 70000
DS12025_12H -FG/RD B 12 7.0 to 13.2 0.75 9.00 3400 2.942 103.89 10.08 0.397 46.9 70000
DC axial fans
* DS12025_12U -FG/RD B 12 7.0 to 13.2 1.05 12.60 3700 3.251 114.82 11.79 0.464 49.8 70000
DS12025_24U -FG/RD B 24 14.0 to 26.4 0.70 16.80 4000 3.428 121.05 12.99 0.511 51.6 70000
13.2
0.48 12.1
4000RPM
0.5
DC blower fans
0.44 11.0 25.4± 5
3700RPM
0.40
9.9
0.36 3400RPM
8.8
0.32 2800RPM
7.7
0.28 2500RPM
□ 105±0.3
6.6
310±10
0.24 2100RPM
□ 117
10(REF.)
5.5 Ø122
AIR PRESSURE
0.20
.5
4.4
0.16
3.3
0.12
0.08 2.2 □ 10
5±0.3 Ø4.3 Ø4. 3
±0.3 ±0.3
0.04 1.1 □ 12
0±0.5
0.00 0.0
0.00 0.31 0.62 0.93 1.24 1.55 1.86 2.17 2.48 2.79 3.10 3.41 3.72 (M3/MIN)
AC fans
(INCH-H2O)
(CFM)
(MM-H2O)
0.0 10.8 21.6 32.4 43.2 54.0 64.8 75.6 86.4 97.2 108.0 118.8 129.6
AIR FLOW
89
DA SER IES
1 2 0 × 1 2 0 × 3 2 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA12032_48E -FG/RD B 48 36.0 to 56.0 0.05 2.40 1900 1.596 56.38 3.52 0.138 32.0 160000
DA12032_48L -FG/RD B 48 36.0 to 56.0 0.07 3.36 2500 2.145 75.75 6.32 0.248 40.5 140000
DA12032_48M -FG/RD B 48 36.0 to 56.0 0.09 4.32 3150 2.714 95.85 9.98 0.393 47.0 120000
* DA12032_48H -FG/RD B 48 36.0 to 56.0 0.14 6.72 3800 3.299 116.53 14.18 0.558 51.0 100000
* DA12032_48U -FG/RD B 48 36.0 to 56.0 0.23 11.04 4400 3.782 133.56 18.32 0.721 55.5 90000
19.5
0.75
0.5
32± 5
15.6
0.60
4400 RPM
10(REF.)
310±10
11.7
3800 RPM
0.45
3150 RPM
AIR PRESSURE
105±0.3
2500 RPM
114
0.30
7.8
3.9
105
.0±0 Ø4.5
.3 ±0.3 Ø4.5
120 ±0.3
.0±0
(INCH H2O) 0.0
.3
3
0.0 0.7 1.4 2.1 2.8 3.5 4.2 (M /MIN.)
(mm H2O)
AIR FLOW
90
1 2 0 × 1 2 0 × 3 2 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA1232_2E -FG/RD B 12 7.0 to 13.2 0.15 1.80 1900 2.05 72.3 3.1 0.12 33.1 140000
DATA1232_2L -FG/RD B 12 7.0 to 13.2 0.27 3.24 2500 2.70 95.2 5.3 0.21 41.4 120000
DATA1232_2M -FG/RD B 12 7.0 to 13.2 0.44 5.28 3150 3.40 119.9 8.4 0.33 48.1 100000
* DATA1232_2H -FG/RD B 12 7.0 to 13.2 0.72 8.64 3800 4.10 144.7 12.3 0.48 53.3 100000
DC axial fans
* DATA1232_2U -FG/RD B 12 7.0 to 13.2 1.11 13.32 4300 4.64 163.7 15.7 0.62 56.8 100000
DATA1232_8E -FG/RD B 48 28.0 to 56.0 0.06 2.88 1900 2.05 72.3 3.1 0.12 33.1 140000
DATA1232_8L -FG/RD B 48 28.0 to 56.0 0.08 3.84 2500 2.70 95.2 5.3 0.21 41.4 120000
* DATA1232_8M -FG/RD B 48 28.0 to 56.0 0.13 6.24 3150 3.40 119.9 8.4 0.33 48.1 100000
DATA1232_8H -FG/RD B 48 28.0 to 56.0 0.19 9.12 3800 4.10 144.7 12.3 0.48 53.3 100000
* DATA1232_8U -FG/RD B 48 28.0 to 56.0 0.28 13.44 4300 4.64 163.7 15.7 0.62 56.8 100000
0.7 18
4300rpm
16
0.6 3800rpm
DC blower fans
14 ±0.5
3150rpm 32.0
5
0.5
12
2500rpm
AIR PRESSURE
0.4 10
1900rpm
310.0 ±10
10(REF.)
0.3 8
□105.0±0.3
□114.0
6 Ø132
0.2
4
0.1
2 □10 Ø 4.5
5.0± ±0.3
0.3 Ø4.5
□12 ±0.3
0.0 0 0.0±
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 (M3/MIN) 0.5
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
91
1 2 0 × 1 2 0 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 5 Blades
* Rotational direction CCW view from front face
* Weight: 256g (9.03 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DAKA1238_12E FG B 12 5.0 to 13.2 0.4 4.8 2100 2.515 88.77 3.59 0.141 33.89 70000
DAKA1238_12L FG B 12 5.0 to 13.2 0.5 6 2600 3.133 110.59 5.64 0.222 40.23 70000
DAKA1238_12M FG B 12 5.0 to 13.2 0.8 9.6 3200 3.866 136.44 9.27 0.365 46.30 70000
* DAKA1238_12H FG B 12 5.0 to 13.2 1.5 18 3900 4.752 167.73 14.20 0.559 52.55 70000
DAKA1238_12U FG B 12 5.0 to 13.2 2.5 30 4800 5.875 207.37 21.20 0.835 57.80 70000
0.90 23.0
300±10
□ 105.0±0.3
0.36 9.2
Ø 115
.6
0.27 6.9
0.18 4.6
0.09 2.3 □1
0 Ø4.5
□ 1 5.0±0.3
20.0
±0.5
0.00 0.0
0.00 0.59 1.18 1.77 2.36 2.95 3.54 4.13 4.72 5.31 5.90 6.49 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
92
1 2 0 × 1 2 0 × 3 8 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA1238_2L -FG/RD B 12 7 to 13.8 0.32 3.84 2600 3.059 108 7.0 0.275 40.1 167500
* DATA1238_2M -FG/RD B 12 7 to 13.8 0.51 6.12 3200 3.796 134 10.5 0.413 46.1 147500
DATA1238_2H -FG/RD B 12 7 to 13.8 0.86 10.32 3800 4.532 160 14.6 0.574 51 132500
DATA1238_2U -FG/RD B 12 7 to 13.8 1.3 15.6 4400 5.269 186 19.1 0.751 54.9 125000
DC axial fans
DATA1238_8L -FG/RD B 48 28 to 56 0.11 5.28 2600 3.059 108 7.0 0.275 40.1 167500
DATA1238_8M -FG/RD B 48 28 to 56 0.15 7.2 3200 3.796 134 10.5 0.413 46.1 147500
DATA1238_8H -FG/RD B 48 28 to 56 0.22 10.56 3800 4.532 160 14.6 0.574 51 132500
* DATA1238_8U -FG/RD B 48 28 to 56 0.36 17.28 4400 5.269 186 19.1 0.751 54.9 125000
21.0
0.80
18.9
0.72
±0.5 5
38.0
16.8
0.64
DC blower fans
4400 RPM
14.7
0.56
3800 RPM
12.6
0.48
3200 RPM
10(REF.)
310±10
0.40 10.5
AIR PRESSURE
105.0±0.3
2600 RPM
115.6
0.24 6.3
0.16 4.2
□10 Ø4.5
5.0 ±0.3
□12 ±0.3 Ø4.5
±0.3
0.08 2.1 0.0±
0.5
0.00 0.0
0.00 1.06 2.12 3.18 4.24 5.30 5.83 (M3/MIN)
(INCH-H2O)
(MM-H2O)
(CFM)
AC fans
93
1 2 0 × 1 2 0 × 3 8 m m 1 2 v ,4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DBTB1238_2M -FG/RD B 12 7 to 13.2 1.15 13.80 4000 4.353 153.73 20.82 0.820 58.0 132500
DBTB1238_2H -FG/RD B 12 7 to 13.2 1.95 23.40 4800 5.270 186.09 29.44 1.159 63.0 125000
* DBTB1238_2U -FG/RD B 12 7 to 13.2 2.95 35.40 5500 6.109 215.74 37.98 1.495 66.0 125000
DBTB1238_8M -FG/RD B 48 28 to 56 029 13.92 4000 4.353 153.73 20.82 0.820 58.0 132500
DBTB1238_8H -FG/RD B 48 28 to 56 0.48 23.04 4800 5.270 186.09 29.44 1.159 63.0 125000
* DBTB1238_8U -FG/RD B 48 28 to 56 0.72 34.56 5500 6.109 215.74 37.98 1.495 66.0 125000
* DBTB1238_8S -FG/RD B 48 28 to 56 0.99 47.52 6200 6.961 245.84 47.99 1.889 69.5 115000
50
1.8 45
6200 RPM ±0.5
38.0
1.6 40 5
5500 RPM
1.4 35
4800 RPM
1.2 30
AIR PRESSURE
4000 RPM
10(REF.)
310±10
1.0 25
105.0±0.3
116.6
0.8 20 Ø13
0.6
0.6 15
0.4 10
(MM-H2O)
94
2B SER IES
1 2 0 × 1 2 0 × 3 8 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
2B12038_12M -FG/RD B 12 7.0 to 13.2 1.52 18.24 4000 4.857 171.46 17.8 0.701 59.5 132500
2B12038_12H -FG/RD B 12 7.0 to 13.2 2.40 28.80 4800 5.844 206.28 26.2 1.031 65.0 125000
* 2B12038_12U -FG/RD B 12 7.0 to 13.2 3.88 46.56 5500 6.649 234.71 34.4 1.354 68.5 115000
* 2B12038_48M -FG/RD B 48 28.0 to 56.0 0.36 17.28 4000 4.857 171.46 17.8 0.701 59.5 132500
DC axial fans
* 2B12038_48H -FG/RD B 48 28.0 to 56.0 0.58 27.84 4800 5.844 206.28 26.2 1.031 65.0 125000
* 2B12038_48U -FG/RD B 48 28.0 to 56.0 0.93 44.64 5500 6.649 234.71 34.4 1.354 68.5 115000
* 2B12038_48S -FG/RD B 48 28.0 to 56.0 1.27 60.96 6200 7.530 265.82 44.2 1.740 71.5 115000
50
1.8 45
6200 RPM
DC blower fans
1.6 40
5500 RPM 38.0
±0.5
1.4 35 5
4800 RPM
1.2 30
AIR PRESSURE
4000 RPM
1.0 25
0.8 20
10(REF.)
105±0.3
0.6 Ø11
310±10
15 5.4
0.4 10
0.2 5
105.0
0.0 0 ±0 Ø4.5
0.0 1.6 3.2 4.8 6.4 8.0 (M3/MIN) 120.0 .3 ±0.3 Ø4.5
±0.5 ±0.3
(INCH-H2O)
(CFM)
(MM-H2O)
AC fans
95
DB SER IES
1 2 7 × 1 2 7 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 492g (17.35 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DB12738_12E -FG/RD B 12 7 to 13.2 0.4 4.8 2700 3.223 113.83 9.26 0.365 48.2 142500
DB12738_12L -FG/RD B 12 7 to 13.2 0.62 7.44 3100 3.625 128.01 12.26 0.483 51.9 142500
DB12738_12M -FG/RD B 12 7 to 13.2 0.8 9.6 3500 4.154 146.68 14.74 0.580 55.3 142500
DB12738_12H -FG/RD B 12 7 to 13.2 1.1 13.2 3900 4.648 164.15 18.70 0.736 57.7 142500
* DB12738_12U -FG/RD B 12 7 to 13.2 1.45 17.4 4300 5.401 190.73 23.70 0.933 60.1 125000
* DB12738_12S -FG/RD B 12 7 to 13.2 1.8 21.6 4600 5.673 200.35 26.64 1.049 61.7 90000
* DB12738_12F -FG/RD B 12 7 to 13.2 2.05 30 5000 6.097 215.30 32.10 1.264 64.1 70000
1.20 31.0
0.5
1.08 27.9 38±
5
24.8
5000RPM 5.2
0.96
4600RPM
0.84 21.7 4300RPM
3900RPM
AIR PRESSURE
0.72 18.6
3500RPM
3100RPM
10 (REF.)
0.60 15.5
310±10
2700RPM
113.3±0.3
0.48 12.4
123
0.12 3.1
(MM-H2O)
96
DB SER IES
1 2 7 × 1 2 7 × 3 8 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DB12738_48E -FG/RD B 48 28 to 56 0.14 6.72 2700 3.223 113.83 9.26 0.365 48.2 142500
DB12738_48L -FG/RD B 48 28 to 56 0.18 8.64 3100 3.625 128.01 12.26 0.483 51.9 142500
DB12738_48M -FG/RD B 48 28 to 56 0.22 10.56 3500 4.154 146.68 14.74 0.580 55.3 142500
DB12738_48H -FG/RD B 48 28 to 56 0.28 13.44 3900 4.648 164.15 18.70 0.736 57.7 142500
DC axial fans
* DB12738_48U -FG/RD B 48 28 to 56 0.42 20.16 4300 5.401 190.73 23.70 0.933 60.1 125000
* DB12738_48S -FG/RD B 48 28 to 56 0.44 21.12 4600 5.673 200.35 26.64 1.049 61.7 90000
* DB12738_48F -FG/RD B 48 28 to 56 0.55 26.4 5000 6.097 215.30 32.10 1.264 64.1 70000
1.20 31.0
blower fans
24.8
5000RPM 5
0.96
4600RPM
0.84 21.7 4300RPM
3900RPM
AIR PRESSURE
0.72 18.6
3500RPM
DCfans
10 (REF.)
3100RPM
310±10
0.60 15.5
113.3±0.3
2700RPM
DC blower
12.4
123
0.48 Ø14
1
0.36 9.3
0.24 6.2
(CFM)
(INCH-H2O)
(MM-H2O)
fans
AIR FLOW
AC
97
1 2 7 × 1 2 7 × 3 8 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CCW view from front face
* Weight: 450g (15.87 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA1338_2E -FG/RD B 12 7 to 13.2 0.55 6.6 3400 3.402 120.14 12.21 0.481 48 142500
DATA1338_2L -FG/RD B 12 7 to 13.2 0.65 7.8 3800 3.783 133.61 14.5 0.571 51 142500
DATA1338_2M -FG/RD B 12 7 to 13.2 0.83 9.96 4200 4.204 148.48 17.4 0.685 54 142500
* DATA1338_2H -FG/RD B 12 7 to 13.2 1.01 12.12 4600 4.613 162.91 21.5 0.846 56 142500
* DATA1338_2U -FG/RD B 12 7 to 13.2 1.26 15.12 5000 5.019 177.26 26 1.024 59 142500
DATA1338_2S -FG/RD B 12 7 to 13.2 1.59 19.08 5400 5.363 189.38 28.6 1.126 61 125000
DATA1338_2F -FG/RD B 12 7 to 13.2 2.08 24.96 6000 6.019 212.57 34.6 1.362 63 70000
1.40 36.0
1.26 32.4
0.5
28.8 6000RPM 38±
1.12 0.3
6.0±
5400RPM 6.0±
0.3
0.98 25.2
5000RPM
AIR PRESSURE
4600RPM
310 ±10
0.84 21.6
4200RPM
0.70 18.0 3800RPM
113.3±0.3
3400RPM
123
0.42 10.8
0.28 7.2
113.3
±0.3 Ø4.5 Ø4.5
0.14 3.6 127± ±0.3 ±0.3
0.5
0.00 0.0
0.00 1.20 2.40 3.60 4.80 6.00 7.20 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AIR FLOW
98
1 2 7 × 1 2 7 × 3 8 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA1338_8E -FG/RD B 48 36 to 60 0.17 8.16 3400 3.402 120.14 12.21 0.481 48 142500
DATA1338_8L -FG/RD B 48 36 to 60 0.20 9.6 3800 3.783 133.61 14.5 0.571 51 142500
DATA1338_8M -FG/RD B 48 36 to 60 0.23 11.04 4200 4.204 148.48 17.4 0.685 54 142500
* DATA1338_8H -FG/RD B 48 36 to 60 0.28 13.44 4600 4.613 162.91 21.5 0.846 56 142500
DC axial fans
* DATA1338_8U -FG/RD B 48 36 to 60 0.33 15.84 5000 5.019 177.26 26 1.024 59 142500
DATA1338_8S -FG/RD B 48 36 to 60 0.39 18.72 5400 5.363 189.38 28.6 1.126 61 125000
DATA1338_8F -FG/RD B 48 36 to 60 0.52 24.96 6000 6.019 212.57 34.6 1.362 63 70000
DATA1338_4E -FG/RD B 24 14 to 26.4 0.30 7.2 3400 3.402 120.14 12.21 0.481 48
DATA1338_4L -FG/RD B 24 14 to 26.4 0.36 8.64 3800 3.783 133.61 14.5 0.571 51
DATA1338_4M -FG/RD B 24 14 to 26.4 0.45 10.8 4200 4.204 148.48 17.4 0.685 54
DATA1338_4H -FG/RD B 24 14 to 26.4 0.54 13.96 4600 4.613 162.91 215 0.846 56
1.40 36.0
DATA1338_4U -FG/RD B 24 14 to 26.4 0.65 15.6 5000 5.019 177.26 26 1.024 59
1.26
DATA1338_4S 32.4
-FG/RD B 24 14 to 26.4 0.78 18.72 5400 5.363 189.38 28.6 1.126 61
DC blower fans
0.98 25.2
DATA1338_2L -FG/RD B 12 7 to 13.2 5000RPM
0.65 7.8 3800 3.783 133.61 14.5 0.571 51
AIR PRESSURE
4600RPM
310 ±10
DATA1338_2M
0.84 21.6
-FG/RD B 12 7 to 13.2 0.83 9.96 4200 4.204 148.48 17.4 0.685 54
4200RPM
DATA1338_2H -FG/RD B 12 7 to 13.2 1.01 12.12 4600 4.613 162.91 215 0.846 56
0.70 18.0 3800RPM
113.3±0.3
DATA1338_2F
0.42 -FG/RD
10.8 B 12 7 to 13.2 2.08 24.96 6000 6.019 212.57 34.6 1.362 63
0.28 7.2
113.3
±0.3 Ø4.5 Ø4.5
0.14 3.6 127± ±0.3 ±0.3
0.5
0.00 0.0
0.00 1.20 2.40 3.60 4.80 6.00 7.20 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
AIR FLOW
99
1 7 2 × 1 5 0 × 2 5 m m
* Material: Impeller: Plastic (UL 94V-0) & Frame: Diecast Aluminum
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 7 Blades
* Rotational direction CW view from front face
* Weight: 450g (15.87 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DATA1525_2X -FG/RD B 12 7 to 13.2 0.56 6.72 2400 4.300 151.84 7.28 0.287 47.1 157500
DATA1525_2E -FG/RD B 12 7 to 13.2 0.71 8.52 2700 4.874 172.13 9.57 0.377 50.7 157500
* DATA1525_2L -FG/RD B 12 7 to 13.2 1.02 12.24 3000 5.524 195.07 11.78 0.464 53.0 157500
DATA1525_2M -FG/RD B 12 7 to 13.2 1.18 14.16 3200 5.952 210.20 13.10 0.516 54.9 157500
* DATA1525_2H -FG/RD B 12 7 to 13.2 1.40 16.80 3400 6.173 218.01 14.50 0.571 57.0 147500
DATA1525_2U -FG/RD B 12 7 to 13.2 1.84 22.08 3700 6.760 238.73 17.00 0.669 59.6 147500
* DATA1525_2S -FG/RD B 12 7 to 13.2 2.27 27.24 4000 7.453 263.21 20.30 0.800 61.3 125000
24.0
0.90 4000RPM
22.0 144.4
3700RPM
0.80 20.0
3400RPM
+0.8
0.70 18.0 -0.3
3200RPM 25.4 0.1
8.0±
16.0
0.60 3000RPM Ø16
2.0±
14.0 0.3
2700RPM
Ø 172.0±0.5
AIR PRESSURE
0.50
10 (REF.)
12.0
2400RPM
310±10
0.40 10.0
Ø4.3±0.3
8.0 Ø15
0.30 6.4
6.0
0.20
4.0
0.10
2.0
Ø4.3
0.00 0.0 ±0.3
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 (M3/MIN) 150
.0±0
.5
(CFM)
(INCH-H2O)
(MM-H2O)
100
1 7 2 × 1 5 0 × 2 5 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DATA1525_8X -FG/RD B 48 32.0 to 80 0.14 6.72 2400 4.300 151.84 7.28 0.287 47.1 157500
DATA1525_8E -FG/RD B 48 32.0 to 80 0.19 9.12 2700 4.874 172.13 9.57 0.377 50.7 157500
* DATA1525_8L -FG/RD B 48 32.0 to 80 0.23 11.04 3000 5.524 195.07 11.78 0.464 53.0 157500
DATA1525_8M -FG/RD B 48 32.0 to 80 0.29 13.92 3200 5.952 210.20 13.10 0.516 54.9 157500
DC axial fans
* DATA1525_8H -FG/RD B 48 32.0 to 80 0.35 16.80 3400 6.173 218.01 14.50 0.571 57.0 147500
DATA1525_8U -FG/RD B 48 32.0 to 80 0.43 20.64 3700 6.760 238.73 17.00 0.669 59.6 147500
* DATA1525_8S -FG/RD B 48 32.0 to 80 0.58 27.84 4000 7.453 263.21 20.30 0.800 61.3 125000
24.0
0.90 4000RPM 144.4
22.0
3700RPM
0.80 20.0 +0.8
DC blower fans
3400RPM -0.3
25.4 0.1
0.70 18.0 8.0±
3200RPM Ø16
16.0 2.0±
0.3
0.60 3000RPM
Ø172.0±0.5
10 (REF.)
14.0
2700RPM
AIR PRESSURE
0.50
310±10
12.0
2400RPM
Ø4.3±0.3
6.0
0.20
4.0
0.10 Ø4.3
2.0 ±0.3
150.0
0.00 0.0 ±0.5
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
101
1 7 2 × 1 5 0 × 5 1 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DATA1551_8L -FG/RD B 48 24.0 to 60.0 0.54 25.9 3700 7.35 259.5 25.1 0.99 59.0 110000
* DATA1551_8M -FG/RD B 48 24.0 to 60.0 0.82 39.4 4300 8.64 305.1 34.6 1.36 63.0 100000
DATA1551_8H -FG/RD B 48 24.0 to 60.0 1.15 55.2 4900 9.91 350.0 44.7 1.76 66.0 90000
* DATA1551_8U -FG/RD B 48 24.0 to 60.0 1.65 79.2 5500 11.15 393.7 55.1 2.17 68.5 70000
60.0
2.10 54.0
5500RPM +0.8
.3 Ø16
50.8 -0 .2
9.6
48.0 3±0
1.80 4900RPM
42.0
4300RPM Ø16
1.50 2.0±
0.2
36.0
Ø172.0 +0.40
-0.30
3700RPM
310±10
AIR PRESSURE
24.0
0.90
55°
55°
18.0
0.60
Ø15
12.0 1.0±
0.2
0.30
6.0
150.0 Ø4.3
±0.2 ±0.3
0.00 0.0 Ø16
0.00 2.40 4.80 7.20 9.60 12.00 (M3/MIN) 2.0±
0.2
(INCH-H2O)
(CFM)
(MM-H2O)
AIR FLOW
102
DB SER IES
1 7 2 × 1 5 0 × 5 1 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
* DB15051_48E -FG/RD B 48 32.0 to 80.0 0.73 35.0 4000 8.29 292.67 30.81 1.21 61.5 110000
* DB15051_48L -FG/RD B 48 32.0 to 80.0 0.98 47.0 4400 9.15 323.25 37.20 1.46 63.5 100000
DB15051_48M -FG/RD B 48 32.0 to 80.0 1.25 60.0 4800 10.15 358.30 44.26 1.74 65.5 90000
DB15051_48H -FG/RD B 48 32.0 to 80.0 1.58 75.8 5200 10.97 387.50 51.90 2.04 68.0 70000
DC axial fans
* DB15051_48U -FG/RD B 48 32.0 to 80.0 1.89 90.7 5500 11.61 409.82 57.28 2.26 69.0 70000
* DB15051_48S -FG/RD B 48 32.0 to 80.0 2.70 129.6 6200 12.88 454.93 73.00 2.87 72.5 70000
DC blower fans
50.8
2.53 63.8 6.5
2.30 58.0 7.0
6200RPM
2.07 52.2
5500RPM
1.84 46.4
5200RPM
Ø172.0±0.5
310±10
1.61 40.6
4800RPM
1.38 34.8 55.5
AIR PRESSURE
4400RPM ° 55.5
°
10(REF.)
1.15 29.0
4000RPM
0.92 23.2
0.69 17.4
0.46 11.6 Ø16
0.0±
0.23 5.8 0.3 Ø4.3
Ø4.3 ±0.3
150.0 ±0.3
0.00 0.0 ±0.2
0.00 2.22 4.44 6.66 8.88 11.10 13.32 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
AC fans
103
DA SER IES
Ø 1 7 2 × 5 1 m m 1 2 v ,4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DA17251_12L -FG/RD B 12 7 to 13.2 2.1 25.2 3700 7.30 257.67 26.10 1.03 60 180000
DA17251_12M -FG/RD B 12 7 to 13.2 3.4 40.8 4300 8.62 304.57 35.50 1.40 63 180000
* DA17251_12H -FG/RD B 12 7 to 13.2 5.1 61.2 4900 9.93 350.63 44.30 1.74 66 130000
DA17251_48M -FG/RD B 48 32 to 56 0.88 42.2 4300 8.62 304.57 35.50 1.40 63 180000
DA17251_48H -FG/RD B 48 32 to 56 1.1 52.8 4900 9.93 350.63 44.30 1.74 66 130000
* DA17251_48U -FG/RD B 48 32 to 56 1.6 76.8 5500 11.11 392.52 53.30 2.10 68 130000
63.8
2.30 58.0
+0.8
5500 50.8
-0.3
2.07 52.2 7.5
4900 10(R
EF.)
1.84 46.4 8
0±0
.3
4300 Ø18
1.61 40.6 Ø16
6
3700
AIR PRESSURE
310 ±10
1.38 34.8
1.15 29.0 55.5
°
°
0.92 23.2 55.5
0.69 17.4
Ø4.3
10(REF.)
Ø4.3
0.23 5.8 ±0.3
0.00 0.0
0.00 2.22 4.44 6.66 8.88 11.10 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
104
2 0 0 × 7 0 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
DATA2070_8L -FG/RD B 48 28.0 to 56.0 0.39 18.72 2200 7.079 250.0 12.4 0.488 44.4 70000
DATA2070_8M -FG/RD B 48 28.0 to 56.0 0.52 24.96 2700 8.656 305.7 18.5 0.728 49.1 70000
* DATA2070_8H -FG/RD B 48 28.0 to 56.0 0.8 38.4 3400 11.117 392.6 30.4 1.197 55.5 70000
* DATA2070_8U -FG/RD B 48 28.0 to 56.0 1.37 65.76 4100 13.451 475.0 43.5 1.713 60 70000
DC axial fans
* DATA2070_8S -FG/RD B 48 28.0 to 56.0 2.1 100.8 4800 15.843 559.5 56.0 2.205 65 70000
57.0
2.20
4800 RPM
51.3
1.98 4100 RPM
DC blower fans
±0.5
3400 RPM 70.0
1.76 45.6
2700 RPM 12
39.9
1.54 2200 RPM
AIR PRESSURE
147.1±0.3
0.88 22.8
0.66 17.1
0.44 11.4
147.1 Ø4.3 Ø4.5
±0.3 ±0.3 ±0.3
0.22 5.7 Ø 20
0.0±
0.5
0.00 0.0
0.00 3.18 6.36 9.54 12.72 15.90 19.08 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
AIR FLOW
105
Company profile
Blower Fans for DC Operations 108
Information
DC axial fans
DC blower fans
AC fans
107
Air Flow
Series
Page
mm CFM 0 10 20 30 40 50 60 80 90 100 200 300 400 500 600 700 800 900 1000
CFM 0 10 20 30 40 50 60 80 90 100 200 300 400 500 600 700 800 900 1000
gs
earin
or
all B
or
ens
ens
s/B
ut
re s
re s
l inp
ring
atu
atu
put
ion
ntro
C
per
Bea
per
rol in
tect
, CC
Tem
e Co
Tem
eve
ions
pro
, CE
ont
55
al
l
igna
-Sle
logu
rnal
Sign
ens
TUV
= IP
rnal
fog
MC
e
FG S
AHB
Dim
Exte
Ana
Pag
Inte
IP >
Salt
PW
UL,
RD
Blower Fans
Series mm
BA05125 51 × 25 Yes 109
BA6025 60 × 25 Yes 110
BNTA1025 Ø100 × 25 Yes 111
BA10033 100 × 33 Yes 112
BA12032 120 × 32 Yes 113
BN12054 Ø120 × 54 Yes 114
BN13391 Ø133 × 91 Yes 115
BN17569 Ø175 × 69 Yes 116
BA18080 180 × 80 Yes 117
BN25599 Ø255 × 99 Yes 118
108
BA SER IES
Ø5 1 × 2 5 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1061 AWG #26 or Equivalent
* Impeller: 31 Blades
* Rotational direction CCW view from front face
* Weight: 26g (1.27 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BA05125_12L FG/RD B 12 5.0 to 13.2 0.20 2.4 3500 0.1438 5.07 4.916 0.1935 29.42 70000
BA05125_12M FG/RD B 12 5.0 to 13.2 0.25 3.00 4500 0.1874 6.618 9.07 0.3571 38.34 70000
* BA05125_12H FG/RD B 12 5.0 to 13.2 0.30 3.60 5500 0.2256 7.965 15.02 0.5913 41.17 70000
BA05125_12U FG/RD B 12 5.0 to 13.2 0.35 4.20 6200 0.2621 9.255 20.382 0.8024 45.4 70000
DC axial fans
BA05125_12S FG/RD B 12 5.0 to 13.2 0.45 5.40 7000 0.2981 10.527 27.801 1.0945 48.52 70000
1.299 33.0
10(RE
F.)
1.181 30.0 310± Ø4.5
10
DC blower fans
51.0±0.25
6200RPM
0.827 21.0
47.35
43.0
5500RPM
AIR PRESSURE
27.35
0.709 18.0
1.70
4500RPM
0.591 15.0
3500RPM
0.472 12.0
0.354 9.0
38.0
18.8
±0.5
1.2
0.236 6.0
24.4
44.5 5
0.118 3.0 ±0.5
51.0
±0.5
0.000 0.0
0.000 0.035 0.070 0.105 0.140 0.175 0.210 0.245 0.280 0.315 0.350 0.385 0.420 (M3/MIN)
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
0.0 1.2 2.5 3.7 4.9 6.2 7.4 8.6 9.9 11.1 12.4 13.6
AIR FLOW
109
BA SER IES
Ø 6 0 × 2 5 m m 1 2 v ,2 4 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BA06025_ 12L FG B 12 10.8 to 13.2 0.25 3.00 2500 0.1826 6.447 4.339 0.1708 29.1 70000
BA06025_ 12M FG B 12 10.8 to 13.2 0.30 3.60 3500 10.2496 8.813 10.449 0.4114 39.12 70000
* BA06025_ 12H FG B 12 10.8 to 13.2 0.35 4.20 4500 0.3286 11.602 20.772 0.8178 43.83 70000
BA06025_ 24L FG B 24 21.6 to 26.4 0.20 4.80 2500 0.1826 6.447 4.339 0.1708 29.1 70000
BA06025_ 24M FG B 24 21.6 to 26.4 0.25 6.00 3500 10.2496 8.813 10.449 0.4114 39.12 70000
* BA06025_ 24H FG B 24 21.6 to 26.4 0.30 7.20 4500 0.3286 11.602 20.772 0.8178 43.83 70000
22.0
0.80 20.0
0.72 ±0.3
18.0 25.0
4500RPM 1.80
0.64 16.0
0.56 14.0
10(REF.)
AIR PRESSURE
310 ±10
0.48 12.0
0.40 10.0
30.80
0.32 8.0
2500RPM
50.0±0.5
0.24 6.0
60.0±0.25
53.73
0.16
26.73
4.0
(MM-H2O)
110
Ø 1 0 0 × 2 5 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BNTA1025B8S -FG B 48 36 to 56 0.42 20.16 6700 1.997 70.52 62.80 2.472 65.1 120000
DC axial fans
INLET RING
2.0
66.0
2.50
R2.56
60.0
10(REF.)
2.25
54.0
2.00
310±10
48.0 25.9±1.0
6700RPM
23.5±1.0
DC blower fans
1.75
42.0
6.5 ±1.0
1.50
AIR PRESSURE
36.0
1.25
30.0
1.00
Ø72 ±0.5
Ø56 ±0.5
24.0
0.75 18.0
0.50 12.0
0.25 6.0
Screw Depth 6
(CFM)
(INCH-H2O)
(MM-H2O)
AC fans
111
BA SER IES
Ø 1 0 0 × 3 3 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 43 Blades
* Rotational direction CCW view from front face
* Weight: 180 g (6.35 OZ)
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BA10033_ 12L -FG/RD B 12 7.0 to 13.8 0.38 4.56 2700 0.685 24.20 18.93 0.745 48.0 50000
BA10033_ 12M -FG/RD B 12 7.0 to 13.8 0.66 7.92 3200 0.812 28.67 29.18 1.149 52.4 50000
BA10033_ 12H -FG/RD B 12 7.0 to 13.8 0.88 10.56 3600 0.910 32.13 34.45 1.356 54.7 50000
BA10033_ 12U -FG/RD B 12 7.0 to 13.8 1.55 18.60 4200 1.094 38.63 50.59 1.992 58.5 50000
BA10033_ 12S -FG/RD B 12 7.0 to 13.2 1.90 22.80 5000 1.290 45.57 73.64 2.900 62.5 50000
10(R
80.0 EF.)
3.0
5000RPM 310±
10
70.0 0.2
3+-0
2.5 4200RPM
32±0.3
60.0
3600RPM
94.3±0.5
Ø46±0.3
Ø64±0.3
2.0 50.0
.3
3±0
39±0.3
AIR PRESSURE
3200RPM
52±0.5
40.0
1.5
2700RPM
30.0
44.9±0.3
57.9±0.5
1.0
Ø4.5±0.3
20.0
0.5 39±
0.3 32±
0.3
10.0
97.2
±0.5 50±0.5 0.3
28±
0.5
0.0 0.0 33±
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 (M3/MIN)
(INCH-H2O)
(CFM)
(MM-H2O)
112
BA SER IES
Ø 1 2 0 × 3 2 m m
* Material: Impeller & Frame: Plastic (UL 94V-0)
* Lead Wires: UL 1007 AWG #24 or Equivalent
* Impeller: 37 Blades
* Rotational direction CCW view from front face
* Weight: 256 g (9.03 OZ)
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BA12032_ 12H FG B 12 5.0 to 13.2 1.60 19.20 2800 1.098 38.802 34.815 1.370 54.61 70000
BA12032_ 12U FG B 12 5.0 to 13.2 2.00 24.00 3200 1.1994 42.352 40.188 1.5822 56.12 70000
DC axial fans
1.732 44.0
DC blower fans
1.417 36.0
3200RPM 0.3
1.260 32.0 5.0±
Ø4.30
1.102 28.0
2800RPM
AIR PRESSURE
0.945 24.0
10(REF.)
0.787 20.0
310 ±10
0.630 16.0
0.472 12.0
0.315 8.0
0.157 4.0
48.55
0.000 0.0
0.00 0.12 0.24 0.36 0.48 0.60 0.72 0.84 0.96 1.08 1.20 1.32 1.44 (M3/MIN)
(CFM)
AC fans
(INCH-H2O)
(MM-H2O)
0.00 4.24 8.47 12.71 16.94 21.18 25.41 29.65 33.88 38.12 42.35 46.59
±0.3
32.0
AIR FLOW
113
BN SER IES
Ø 1 2 0 × 5 4 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BN12054B_48H -FG/RD B 48 32.0 to 56.0 0.44 21.1 4000 4.253 150.2 28.30 1.114 62.0 80000
* BN12054B_48U -FG/RD B 48 32.0 to 56.0 0.55 26.4 4500 4.684 165.4 35.63 1.403 65.5 80000
BN12054B_48S -FG/RD B 48 32.0 to 56.0 0.75 36.0 5000 5.340 188.6 47.77 1.881 68.0 80000
BN12054B_48F -FG/RD B 48 32.0 to 56.0 1.10 52.8 5500 5.748 203.0 54.70 2.154 71.0 80000
10 (REF.)
300±10
Ø58.0±0.5 65±10
60.0
Ø102.0±0.5
2.00 50.0
5500 RPM
1.60 40.0
5000 RPM
4500 RPM
Ø120 40.5±1.0
1.20 30.0 .0±0.5
4000 RPM
AIR PRESSURE
54±1.0
(CFM)
(MM-H2O)
114
BN SER IES
Ø 1 3 3 × 9 1 m m 1 2 v ,4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BN13391_ 12U -FG/RD B 12 8 to 14 2.70 32.4 3900 5.94 209.63 39.2 1.54 62.0 100000
* BN13391_ 48U -FG/RD B 48 32 to 57 0.70 33.6 3900 5.94 209.63 39.2 1.54 62.0 100000
* BN13391_ 48S -FG/RD B 48 32 to 57 1.00 48.0 4500 7.14 252.1 56.1 2.21 67.0 100000
DC axial fans
10(REF.)
310±10
10(REF.)
Ø96.8±0.5
Ø84.5±0.5
2.5 63.0
56.0
4700RPM DC blower fans
2.0
49.0
4500RPM Ø133 59.6 ±1.0
.0±0.5
42.0 91.0±1.0
1.5 3900RPM
AIR PRESSURE
35.0
*PERFORMANCE MEASURED UNDER
28.0 THE FOLLOWING CONDITION:
1.0
21.0
Ø 58.0±0.5
0.5 14.0
R5.0
7.0
90°X4
AIR FLOW
LABEL
0.0 0.0
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00
(M3/MIN)
(INCH-H2O)
Depth of screw
(MM-H2O)
AC fans
max. 6mm
M4 (5X)
0.0 50.0 100.0 150.0 200.0 250.0
2.0
AIR FLOW (CFM)
115
BN SER IES
Ø 1 7 5 × 6 9 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BN17569_48L -FG/RD B 48 32 to 80 0.50 24.0 2700 7.892 278.72 29.8 1.173 62.5 70000
* BN17569_48M -FG/RD B 48 32 to 80 0.75 36.0 3100 9.086 320.86 40.0 1.575 66.0 70000
BN17569_48H -FG/RD B 48 28 to 60 1.15 55.2 3600 10.575 373.44 54.1 2.130 69.5 70000
BN17569_48U -FG/RD B 48 28 to 53 1.55 74.4 4000 11.68 412.46 67.4 2.654 72.5 70000
10(REF.)
10(REF.)
310±10
70.0
2.50 63.0
Ø131.0±0.5
Ø84.5±0.5
56.0
4000 RPM
2.00
49.0
3600 RPM
AIR PRESSURE
42.0 Ø175
63.0
0.50 14.0
R5
7.0
AIR FLOW
90°X4
LABEL
0.00 0.0
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 (M3/MIN)
(INCH-H2O)
(MM-H2O)
0.0 80.0 160.0 240.0 320.0 400.0 480.0 (CFM) Depth of screw max. 6mm
M4 (5X)
AIR FLOW 2.0
116
BA SER IES
1 8 0 × 1 8 0 × 8 0 m m 4 8 v
Information
Operating Voltage Range
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BA18080_ 48U -FG/RD B 48 36 to 57 0.55 26.4 4050 3.115 110 54.5 2.146 66.5 70000
DC axial fans
74.0±1.0
2.20 56.0
1.98 50.4
4050 RPM 178.9
±1.0
1.76 44.8
DC blower fans
99.0 87.0
±0.5
1.54 39.2 49.5 ±0.5
±0.5
±0.5
59.0
1.32 33.6
AIR PRESSURE
1.10 28.0
0.88 22.4
99.0±0.5
71.0±0.5
0.66 16.8
101.0±0.5
49.5±0.5
0.44 11.2
180.6±1.0
0.22 5.6
M4x
0.7 L
6 (4X
0.00 0.0
)
0.00 0.62 1.24 1.86 2.48 3.10 (M3/MIN) 10(R
EF.)
(CFM)
(INCH-H2O)
310±
(MM-H2O)
AIR FLOW
117
BN SER IES
Ø 2 2 5 × 9 9 m m 4 8 v
Acoustic Noise
Life expectancy
Rated Current
Bearing Type
L10@40℃
Speed
MODEL
PAR T NO. SIG NAL B .T.S.R VDC VDC Am p W a tt R .P.M. m 3 /m in CF M m m H 2 O IN H 2 O d B -A h o u rs
BN22599_48H -FG/RD B 48 36 to 56 2.60 124.8 2700 20.19 702 62.65 2.47 73.5 40000
28
R 25.0
AIR FLOW
2.40 61.0
2.16 54.9
225.0
±0.5 2.0 REF.
1.92 48.8
2700 RPM
1.68 42.7
1.44 36.6
AIR PRESSURE
10 (REF.)
300±10
1.20 30.5
90±10
0.72 18.3
Ø153.0±0.5
Ø99.8±0.5
0.24 6.1
0.00 0.0
0.00 3.98 7.96 11.94 15.92 19.90 23.88 (M3/MIN)
M4 (5X)
(CFM)
(INCH-H2O)
(MM-H2O)
93.0±1.0
0.0 140.6 281.2 421.8 562.4 703.0 99.0±1.0
AIR FLOW
118
Company profile
AC Axial Fans for Operations 120
Information
DC axial fans
DC blower fans
AC fans
119
Air Flow
Series
Page
mm CFM 0 100 200 500 600 800 1000 1200 1500 1800
CFM 0 100 200 500 600 800 1000 1200 1500 1800
120
D7 SER IES
1 2 0 × 1 2 0 × 3 8 m m
* Material: Impeller:Plastic (UL 94 V0) Frame: Aluminum Alloy
* Lead Wires: Wire/Terminal
* Impeller: 5 Blades Type of protection: IP54
* Mass: 486g
* Air flow direction: inlet looking at rotor
Information
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Voltage Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
D7KB1238BBH5w B 230 220 to 240 50/60 0.07/0.07 15/15 2750/3200 101.5/119 0.35/0.44 -10~70 50000 44/48 UL, TUV, CE, CCC
D7KA1238BAH5w B 115 105 to 125 50/60 0.11/0.11 11.5/11.5 2750/3200 101.5/119 0.35/0.44 -10~70 50000 44/48 UL, CCC
DC axial fans
14
0.525
±0.5
38.5
4
4
12
0.45
DC blower fans
10
0.375
8
0.30
10.0(REF.)
3200RPM
6
300±10
AIR PRESSURE
0.225
2750RPM
□115.5
Ø1
35
0.15
4
0.075
2
0.00
□1
0
04.8
0.0 0.57 1.13 1.70 2.26 2.83 3.39 3.96 (M3/MIN.) ±0.3
□1 Ø4.5±
(INCH H2O)
19.5 0.2
±0.5
(MMH2O)
(CFM) Ø4.3±
0.2
AC fans
AIR FLOW
121
D7 SER IES
1 2 0 × 1 2 0 × 3 8 m m
* Material: Impeller:Plastic (UL 94 V0) Frame: Aluminum Alloy
* Lead Wires: Wire/Terminal
* Impeller: 5 Blades Type of protection: IP54
* Rotational direction : CW looking at rotor
* Mass: 482g
* Air flow direction: outlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Voltage Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
PAR T NO. B .T.S.R VAC VAC H z Am p W a tt R .P.M. CF M INCH H 2 O C H o u r d B -A
D7KC1238BBH5W B 230 220 to 240 50/60 0.07/0.07 15/15 2750/3200 98.5/117 0.25/0.34 -10~70 50000 48/53 UL, TUV, CE, CCC
D7KB1238BAH5W B 115 105 to 130 50/60 0.11/0.11 11.5/11.5 2750/3200 98.5/117 0.25/0.34 -10~70 50000 48/53 UL, CCC
14
0.525
±0.5
38.5
4
4
12
0.45
10
0.375
8
0.30
3200RPM
10.0(REF.)
2750RPM
6
AIR PRESSURE
0.225
300±10
□ 104.8±0.3
□ 115.5
35
0.15
Ø1
2
0.075
0.00
Ø4.5±
(MMH2O)
□1 Ø4.3± 0.2
19.5 0.2
±0.5
0 10 20 30 40 50 60 70 80 90 100 110 120 130 (CFM)
AIR FLOW
122
D7 SER IES
1 2 0 × 1 2 0 × 3 8 m m
* Material:
Impeller: Plastic (UL94V-0)
Frame: Plastic
Voltage Rated
Information
* Type of protection: IP54
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
PAR T NO. B .T.S.R VAC H z Am p W a tt R .P.M. CF M INCH H 2 O C d B -A H o u r
D7AA1238BBUCZAW B 220~240 50/60 0.165 21.5 4400 185 0.80 -20~70 62 70000 UL, TUV, CE, CCC
DC axial fans
2 4 .2
0 .9 0
1 3 .2 1 5 .4 1 7 .6 1 9 .8 2 2 .0
0 .8 1
DC blower fans
10±0.5
4400RPM
0 .4 5 0 .5 4 0 .6 3 0 .7 2
338±10
33°
PR ESSU R E
178±5
1 1 .0
0 .3 6
8 .8
0 .2 7
6 .6
AIR
0 .0 0 0 .0 9 0 .1 8
4 .4
2 .2
( M3 / MIN.) 4-Ø4
.3±0.1
0 .0
0 .0 0 0 .5 3 1 .0 6 1 .5 9 2 .1 2 2 .6 5 3 .1 8 3 .7 1 4 .2 4 4 .7 7 5 .3 0 5 .8 3 □ 10
(INCH H O)
5±0.5
(MM H O)
5
2
0.1 0.0
( CF M) □ 12 33.5
2
.2± .4±
0 .0 1 8 .6 3 7 .2 5 5 .8 7 4 .4 9 3 .0 1 1 1 .6 1 3 0 .2 1 4 8 .8 1 6 7 .4 1 8 6 .0 2 0 4 .6 0 33°
3
Ø6
88°
Ø2
3-
AIR F LOW
AC fans
123
D3 SER IES
1 7 2 × 1 5 0 × 3 8 m m
* Material: Steel coating black Frame: Aluminum Alloy
* Lead Wires: Wire/Terminal
* Impeller: 7 Blades Type of protection: IP54
* Mass: 840g
* Air flow direction: inlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Voltage Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
D3KB1738BBH3W B 230 220 to 240 50/60 0.11/0.12 27/28 2800/3200 190/224 0.57/0.70 -10~70 50000 53/57 UL, TUV, CE, CCC
D3KB1738BAH3W B 115 105 to 125 50/60 0.26/0.24 27/28 2800/3200 190/224 0.57/0.70 -10~70 50000 53/57 UL, CCC
21
0.80
±0.5
38.0
18
0.70
15
+0.
0.60
15
2 -0.3
Ø16
Ø4.2±0.2
3250RPM
0.50
1
Ø15
12
Ø4.5±0.2
150±0.5
2800RPM
0.40
AIR PRESSURE
9
0.30
146
6
0.20
3
0.10
(INCH H O) 0.00
172±
0 20 40 60 80 100 120 140 160 180 200 220 240 260 0.5
(CFM)
AIR FLOW
124
D3 SER IES
1 7 2 × 1 5 0 × 5 1 m m
* Material: Steel coating black Frame: Aluminum Alloy
* Lead Wires: Wire/Terminal
Voltage Rated
Information
* Air flow direction: inlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
D3KC1751BBH3W B 220 to 240 50/60 0.12/0.11 27/27 2800/3300 234/275 0.70/0.81 1.0/450 -10~+70 57/61 50000 UL, TUV, CE, CCC
DC axial fans
24.2
±0.5
51.0
0.90
2.5
2.6
20.74
DC blower fans
0.75
.5
2±0
Ø16
17.29
°
2-56
6.2
Ø16
Ø4.6±0.2
0.60
2800RPM 3300RPM
151±0.8
134.5±0.5
13.83
0.45
147.0
10.37
AIR PRESSURE
0.30
6.91
0.15
3.46
Ø4.
6 ±0
. 3
171.5
±0.8
(INCH H O) 0.00
AC fans
125
D3 SER IES
1 7 2 × 1 5 0 × 5 5 m m
* Material: Steel coating black Frame: Aluminum Alloy
* Lead Wires: Wire
* Impeller: 7 Blades Type of protection: IP54
* Rotational direction : CCW looking at rotor
* Mass: 990g
* Air flow direction: inlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Voltage Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
D3KB1755BBH3W B 230 220 to 240 50/60 0.11/0.12 25/28 2800/3300 198.5/234 0.61/0.81 -10~70 50000 51/55 UL, TUV, CE, CCC
D3KB1755BAH3W B 115 105 to 125 50/60 0.26/0.23 25/25 2800/3300 198.5/234 0.60/0.79 -10~70 50000 51/55 UL, CCC
21
±0.5
55.0
0.72
18
2-6
0.59
15
Ø4.3±0.2
6
Ø14
0.47
12
3300RPM
150±0.5
0.36
9
AIR PRESSURE
2800RPM
Ø4.5±0.2
0.23
6
0.11
3
0.0
162±
300±10
(M3/MIN.) 172±
10±2
(MM H O)
2
0.8
2
126
D4 SER IES
2 2 5 × 2 2 5 × 8 0 m m
* Material:
Frame: Aluminum Alloy; Blades : Sheet steel, coated in black; Rotor : Coated in black
* Lead Wires: Wire
* Impeller: 7 Blades
* Rotational direction: CCW looking at rotor
* Type of protection : IP44
* Insulation class : B
Information
* Mass: 2000g
* Air flow direction: inlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
220 ~240 50 0.28 57 2550 505 0.72 1.5/450 -25~60 58 UL, TUV, CE, CCC
D4KA2280BBH3WAW B 63000
220 ~240 60 0.32 71 2900 570 0.69 1.5/450 -25~60 60 UL, CCC
DC axial fans
0.3
80 ±
0
20.0
24
18.0
2.8
0.70
16.0
Ø240
0.60
DC blower fans
2900RPM
14.0
0.50
2550RPM
12.0
10.0
□169.7
0.40
8.0
AIR PRESSURE
0.30
Ø220
6.0
0.20
∅4.5
4.0
0.10
2.0
o225
Ø4.5 ± 0.1
0.0
0.00
0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5
(M3/MIN)
(INCH H2O)
(MM H2O)
0.0 60 120 180 240 300 360 420 480 540 600 640
(CFM)
AC fans
AIR FLOW
127
D5 SER IES
Ø 2 3 2 × 8 0 m m
* Material: Impeller: Plastic (UL 94V0) Frame: Aluminum Alloy
* Lead Wires: Terminal
* Impeller: 5 Blades
Voltage Rated
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Voltage Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
230 220 to 240 50 0.32 70 2700 480 1.50 -25~+72 65 UL, TUV, CE, CCC
D5KA2380BBH3WAW B 60000
230 220 to 240 60 0.40 92 3000 540 1.65 -25~+72 69 UL, CCC
45.0
1.60
19.98
40.0
2.5
∅240
1.40
35.0
1.20
30.0
3000RPM
1.00
25.0
2700RPM
□169.7
0.80
20.0
AIR PRESSURE
0.60
15.0
∅214
0.40
10.0
∅ 4.5
0.20
5.0
∅ 4.5
□169.7
0.00
0.0
Ø232±
0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0
5
(M3/MIN.)
(INCH H O)
(MM H O)
2
0 50 100 150 200 250 300 350 400 450 500 550 600
(CFM)
AIR FLOW
128
D4 SER IES
2 8 0 × 2 8 0 × 8 0 m m
* Material:
Frame: Aluminum Alloy; Blades : Sheet steel, coated in black; Rotor : Coated in black
* Lead Wires: Wire
* Impeller: 7 Blades
* Rotational direction: CCW looking at rotor
* Type of protection : IP44
* Insulation class : F
Information
* Mass: 3000g
* Rotational direction: CCW looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
220 ~240 50 0.57 129 2550 1088 0.85 4.0/400 -25~60 68 UL, TUV, CE, CCC
D4KA2880BBH3WAW B 63000
220 ~240 60 0.80 182 2650 1130 0.70 4.0/400 -25~45 70 UL, CCC
DC axial fans
0.3
80 ±
20.0
5
29
18.0
3
0.70
∅295
16.0
0.60
DC blower fans
2900RPM
14.0
0.50
2550RPM
12.0
10.0
0.40
□208.6
8.0
AIR PRESSURE
0.30
∅275
6.0
0.20
4.0
∅5.4
0.10
2.0
o 280
0.0
0.00
0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5
Ø5.4 ± 0.1
(M3/MIN)
(INCH H2O)
(MM H2O)
0.0 60 120 180 240 300 360 420 480 540 600 640
(CFM)
AC fans
AIR FLOW
129
B5 SER IES
Ø 1 9 0 × 6 8 .5 m m
* Material: Impeller: Plastic (UL 94V0) Frame: Aluminum Alloy
* Lead Wires: Wire
* Impeller: 7 Blades
Voltage Rated
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
220 ~ 240 50 0.29 64 2500 324 1.29 2.0/450 -25~50 64 UL, TUV, CE, CCC
B5AA1968BBH3WAW B 40000
220 ~ 240 60 0.33 77 2800 369 1.76 2.0/450 -25~55 67 UL, CCC
50Hz 60Hz
52.5
1.80
68.5±1
45.0
63±0.5
14
R10
1.50
37.5
2 Ø58± 0.2
Ø27±0.2
17
30.0
1.20
90°
Ø125.5
Ø190
Ø170
Ø133
Ø90
29
22.5
0.90
AIR PRESSURE
0
45
0.60
15.0
2 M4
6 44.2
Depth of screw
7.5
63
0.30
Max.5mm
0.00
0.0
(MM H O)
2
130
B5 SER IES
Ø 2 2 0 × 7 1 m m
* Material: Impeller: Plastic (UL 94V0) Frame: Aluminum Alloy
* Lead Wires: Wire
* Impeller: 11 Blades
Voltage Rated
Information
* Mass: 1380g
* Air flow direction: inlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
220 ~ 240 50 0.38 86 2350 509 1.32 3.0/450 -25~40 66 UL, TUV, CE, CCC
B5AA2271BBH3WAW B 40000
220 ~ 240 60 0.38 86 2500 542 1.71 2.0/450 -25~40 67 UL, CCC
DC axial fans
50Hz 60Hz
45.0
1.60
40.0
71±1
63±0.5
1.40
35.0
21
DC blower fans
2
1.20
Ø58±0.2
30.0
Ø27±0.2
R2
2
1.00
17
25.0
Ø252
Ø155
Ø161
Ø220
Ø90
90°
29
0.80
20.0
0
45
AIR PRESSURE
0.60
15.0
6 2
0.40
10.0
44 M4
64 Depth of screw
Max.5mm
0.20
5.0
0.00
0.0
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0
(INCH H O)
(M3/MIN.)
AC fans
(MM H O)
2
AIR FLOW
131
B5 SER IES
Ø 2 2 5 × 9 9 m m
* Material: Impeller: Plastic (UL 94V0) Frame: Aluminum Alloy
* Lead Wires: Wire
* Impeller: 7 Blades
Voltage Rated
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
220 ~ 240 50 0.60 132 2650 674 2.1 4.0/450 -25~60 73 UL, TUV, CE, CCC
B5AA2299BBH3WAW B 40000
220 ~ 240 60 0.85 188 2950 747 2.8 4.0/450 -25~60 75 UL, CCC
50Hz 60Hz
8 7 .5
3 .0 0
99±1
28
7 5
85
R2
5
2 .5 0
6 2 .5
2 Ø58±0.2
Ø27±0.1
37
2 .0 0
5 0
Ø153.8
Ø225
Ø146
Ø223
Ø90
90°
AIR PR ESSU R E
29
1 .5 0
3 7 .5
0
45
1 .0 0
6
2 5
63 2
89 M4
1 2 .5
0 .5 0
Depth of screw
Max.5mm
(INCH H O) 0 .0 0
0 .0
0 .0 4 .0 8 .0 1 2 .0 1 6 .0 2 0 .0 2 4 .0 2 8 .0
( M3 / MIN.)
(MM H O)
2
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0
AIR F LOW
132
B5 SER IES
Ø 2 5 0 × 8 9 m m
* Material: Impeller: Plastic (UL 94V0) Frame: Aluminum Alloy
* Lead Wires: Wire
* Impeller: 11 Blades
Voltage Rated
Information
* Mass: 2500g
* Air flow direction: inlet looking at rotor
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Capacitor
Speed
MODEL
O μF/VDB
O
PAR T NO. B .T.S.R VAC H z Am p W a tt R .P.M. CF M INCH H 2 C d B -A H o u r
220 ~ 240 50 0.55 125 2400 707 2.00 4.0/450 -25~65 71 UL, TUV, CE, CCC
B5AA2589BBH3WAW B 40000
220 ~ 240 60 0.75 165 2550 745 2.50 4.0/450 -25~45 73 UL, CCC
DC axial fans
50Hz 60Hz
7 0 .0
2 .7 0
89±1
2 .4 0
6 0 .0
85±0.5 31
2 .1 0
2
5 0 .0
DC blower fans
Ø58±0.2
1 .8 0
Ø27±0.2
R2
8
4 0 .0
37
1 .5 0
Ø173.5
Ø164.5
Ø250
Ø255
Ø90
90°
PR ESSU R E
29
1 .2 0
3 0 .0
0
45
0 .9 0
AIR
2 0 .0
6
0 .6 0
45 2
M4
1 0 .0
73.8
0 .3 0
Depth of screw
Max.5mm
(INCH H O) 0 .0 0
(MM H O) 0 .0
0 .0 4 .0 8 .0 1 2 .0 1 6 .0 2 0 .0 2 4 .0
2
( M3 / MIN.)
2
0 .0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0
( CF M)
AC fans
AIR F LOW
133
B2 SER IES
1 8 0 × 1 7 1 .5 × 2 1 5 m m
* Material:
Impeller : Galvanised sheet steel
Housing : Galvanised sheet steel
Voltage Rated
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
PAR T NO. B .T.S.R VAC H z Am p W a tt R .P.M. CF M INCH H 2 O C H o u r d B -A
220 to 240 50 0.84 190 1550 420 1.43 -25~45 50000 59 UL, TUV, CE, CCC
B2AA18M5BBH3WAW B
220 to 240 60 0.88 205 1430 392 1.89 -25~45 50000 56 UL, CCC
185 ±0.15
50Hz 60Hz
5 3 .9
2 .0 9
.1
2-Ø3±0
4 9 .0
1 .9 0
4 4 .1
1 .7 1
3 9 .2
1 .5 2
3 4 .3
1 .3 3
2 9 .4
1 .1 4
171.5 ±0.3
215 ±0.3
PR ESSU R E
88
2 4 .5
0 .9 5
1 9 .6
0 .7 6
73
101
AIR
R7
1 4 .7
0 .5 7
180 ±0.3
0 .3 8
9 .8
0 .1 9
4 .9
0 .0 0
0 .0
0 .0 0 2 .2 2 4 .4 4 6 .6 6 8 .8 8 1 1 .1 0 1 3 .3 2
(INCH H O)
( M3 / MIN.)
(MM H O)
2
300.00 ±10
2
0 .0 7 8 .6 1 5 7 .2 2 3 5 .8 3 1 4 .4 3 9 3 .0 4 7 1 .6
( CF M)
AIR F LOW
134
D5 SER IES
1 7 2 × 1 5 0 × 8 4 m m
* Material:
Impeller: Plastic (UL94V-0)
Frame: Aluminum alloy
Voltage Rated
Information
* Air flow direction: inlet looking at rotor
* Type of protection: IP54
Operating Voltage Range
Temperature Range
Air Flow Maximum
Power Input Rated
Acoustic Noise
Current Rated
Bearing Type
Certification
Frequency
Speed
MODEL
O
PAR T NO. B .T.S.R VAC H z Am p W a tt R .P.M. CF M INCH H 2 O C d B -A H o u r
D5AA1784BDLCZAW B 85~264 50/60 0.28 20.5 3350 239 0.98 -20~70 56.8 63000 UL, TUV, CE, CCC
DC axial fans
1 .1 0
2 8 .0
+0.8
84.3 -0.3
50.8
0 .9 4
2 4 .0
DC blower fans
°
0 .7 9
2 0 .0
55.5
3350RPM
1 6 .0
0 .6 3
PR ESSU R E
1 2 .0
0 .4 7
8-Ø4.3 ± 0.3
150±0.5
AIR
0 .3 1
8 .0
55.5°
4 .0
0 .1 6
0 .0 0
0 .0
Ø162
0 .0 1 .0 2 .0 3 .0 4 .0 5 .0 6 .0 7 .0 ±0.3
(INCH H O)
( M3 / MIN.)
(MM H O)
Ø172±
2
0.5
AC fans
0 2 5 5 0 7 5 1 0 0 1 2 5 1 5 0 1 7 5 2 0 0 2 2 5 2 5 0
( CF M)
AIR F LOW
135
W e s t In d u s t r i a l Pa r k .X i n y a n g Co m m u n i t y 7 F - 3 , No .2 4 W u - Ch u a n 2 R d ., H s i n - No . 2 4 8 -2 7 , Si n - s h e n g R d ., Ci a n - j h e n AVC Ja p a n
Sh a j i n g B r a n c h , B a o a n Di s t r i c t , Sh e n z h e n Ch u a n g Ci t y , Ta i p e i 2 4 8 9 2 , Ta i w a n Di st r i ct ,K a o h si u n g 8 0 6 , Ta i w a n AVC K o re a
Ci t y , Ch in a Te l : + 8 8 6 -2 -2 2 9 9 -6 9 3 0 Te l : + 8 8 6 -7 -8 1 5 -7 6 1 2 AVC So u th e a st a si a
Te l : + 8 6 -7 5 5 -3 3 6 6 8 8 8 8 F a x: + 8 8 6 -2 -2 2 9 9 - 6 9 2 9 F a x: + 8 8 6 -7 -5 1 2 - 0 0 1 8 AVC No rth a m e r i ca
F a x: + 8 6 -7 5 5 -3 3 6 6 0 6 0 2 E- m a i l : sa l e s@ a vc. co m .t w AVC So u th a m e r i ca
E- m a i l : sa l e s@ a vc. co m .cn AVC Eu ro p e (G m b H )
AVC Sp a in
w w w .a vc. co m .t w
136