Calculation Header: Rtkcalc Powered by Conval® Version 2.0 (Build 2.0.2)
Calculation Header: Rtkcalc Powered by Conval® Version 2.0 (Build 2.0.2)
Calculation Header: Rtkcalc Powered by Conval® Version 2.0 (Build 2.0.2)
2)
Calculation header
Identifier New calculation
Tag No. / KKS-Nr. PV2
Text 1 Concise valve Examlple 1
Text 2
Text 3
Operating data
Maximum flow Minimum flow
Operating temperature t1 25.0 °C
Pressure upstream of valve p1 15.0 bar(a)
Pressure downstream of valve p2 2.0 bar(a)
Pressure difference p 13.0 bar
Mass flow rate qm 598,610.0 kg/h
Volume flow rate (operating conditions) qv 600.0 m³/h
Discharge coefficient Kv 168.94 m³/h
Type of flow Choking cavitation
Load-dependent values
Calculation standard (noise, lquid) IEC 60534-8-4 (2005-08)
Maximum flow Minimum flow
Stroke/angle-of-rotation ratio s/s100 39.7 %
Flow velocity u1 3.3953 m/s
Sound pressure level of valve (A-weighted) LpAe 82.8 dB(A)
Valve data
Series PV 6911
Safety function Air failure open AFO
Actuator type Pneumatic control valve
Valve style Globe valve
Selected valve size DN DN 250
Pressure class PN 25
1(3)
RTKcalc powered by CONVAL® Version 2.0 (Build 2.0.2)
Valve configuration
Body material Cast steel EN-GP240-GH
Spindle sealing Stuffing box (standard)
Stuffing box material PTFE-carbon chevron-type
Packing type Standard
End connection Flanges with flat face acc. to DIN 2526 form C
Plug/seat sealing metallically sealing
Seat leakage < 0,01% Kvs (class IV)
Seat options Standard
Painting Surface treatment with zinc dust primary coat
Certificate without
Stem heater without
Power supply stem heater -
Max. design temperature TS 250°C
Max. design pressure PS acc. to DIN EN 1092
Actuator selection
Safety reserve fRes 10.0 %
Air supply pressure p,air 6.0 bar(g)
Actuator manufacturer STI
Actuator 420/100
2(3)
RTKcalc powered by CONVAL® Version 2.0 (Build 2.0.2)
Pneumatic actuator
Active area 1366 cm²
Fail-safe position at air failure valve CLOSE
Manual operation without
Positioner without
Input signal -
Output signal -
Pressure indicator without
Position feedback without
Limit alarm (regulated by stroke) -
Operating direction positioner -
Operating direction actuator stem -
Booster -
Solenoid valve / Locking relay without
Voltage solenoid valve -
Airset without
Limit switches without
Warning:
Maximum cavitation (choked flow) p (13.0 bar) > 12.58 bar
Hint:
The calculation according to IEC 60534-8-4 (2005-08) was modified based on measured manufacturer
values.
Confirmation:
Values for Flow velocity - u1 (3.395 m/s) are not critical.
Legend
Calculated value
Lookup value
Warning
Hint
Confirmation
3(3)