Technical Information PVG 100 Proportional Valve Group
Contents
General Information
Acronyms.............................................................................................................................................................................................6
General ................................................................................................................................................................................................ 6
Standard, oil flow direction and setting of max. flow....................................................................................................6
Valve system................................................................................................................................................................................. 7
General features PVG 100, load independent flow control......................................................................................... 7
PVP - pump side module ......................................................................................................................................................... 7
PVB – basic module.................................................................................................................................................................... 8
Actuation module....................................................................................................................................................................... 8
Remote control units ................................................................................................................................................................ 9
PVG 100 function
PVG 100 with open center PVPF...............................................................................................................................................10
PVG 100 with closed center PVPV / PVPVP / PVPVM......................................................................................................... 12
PVG 100 closed center priority steering PVPVP module ........................................................................................... 12
PVG 100 closed center PVPVM module ........................................................................................................................... 12
PVG 100 basic modules PVB.......................................................................................................................................................12
PVG 100 tank modules ................................................................................................................................................................ 13
Load sensing controls...................................................................................................................................................................14
LS control with bleed orifice (do not use with PVG valves).......................................................................................14
Integral PC function................................................................................................................................................................. 14
Load sensing system characteristics:.................................................................................................................................15
Remote pressure compensated controls.............................................................................................................................. 15
Remote pressure compensated system characteristics:............................................................................................ 15
Typical applications for remote pressure compensated systems:..........................................................................16
PVG 100 main spool with pressure compensated control..............................................................................................16
Pressure compensated system characteristics.............................................................................................................. 17
Typical applications for pressure compensated systems...........................................................................................17
PVMR, friction detent....................................................................................................................................................................17
PVMF, mechanical float position lock.....................................................................................................................................17
PVBS, main mpools for flow control (standard).................................................................................................................. 18
PVBS, main spools for flow control (with linear characteristic)..................................................................................... 18
Safety in application
Building in safety............................................................................................................................................................................19
FMEA (Failure Mode and Effect Analysis) IEC EN 61508............................................................................................. 19
Hazard and risk analysis ISO 12100-1/14121.................................................................................................................. 19
Control system example..............................................................................................................................................................19
Typical wiring block diagram example.............................................................................................................................21
Example of fault monitoring.................................................................................................................................................23
PVG 32 – Mainly used in system with fixed displacement pumps..........................................................................23
PVG 100 – Alternative LS dump or pilot supply disconnect..................................................................................... 24
PVG 120 – Pump disconnect/block for variable pumps............................................................................................. 24
Technical data
PVG 100 technical data................................................................................................................................................................ 25
PVH, hydraulic actuation............................................................................................................................................................. 25
PVM, mechanical actuation........................................................................................................................................................26
PVE, electrical actuation.............................................................................................................................................................. 26
PVEO ............................................................................................................................................................................................. 27
PVEA, PVEH and PVES..............................................................................................................................................................27
Technical characteristics
PVPF, pump side module............................................................................................................................................................ 28
Open center flow rating.............................................................................................................................................................. 28
Closed center flow rating............................................................................................................................................................ 28
PVB, basic module..........................................................................................................................................................................29
PVB with pressure compensation, closed center PVP...................................................................................................... 30
Hydraulic systems
Contents
Contents
General Information
Acronyms
This table provides a definition of some commonly used terms
General
PVEA
PVEO
PVH PVT
PVMD B
PVMR/PVMF A
P-A
PVB P-B
Q max: P B
PVM Q max: P A
7-9 N•m
[61-79 lbf•in]
General Information
Valve system
PVG 100 is a hydraulic load sensing valve, designed to fulfill efficiency requirements.
From a simple load sensing directional valve to an advanced electro hydraulic controlled load
independent proportional valve the PVG 100 modular system makes it possible to build up a valve group
to fulfill customer requirements. The compact external dimensions of the valve remain unchanged
whatever combination is specified.
‒ Oil flow to an individual function is independent of the load pressure of this function regardless of
sufficient or insufficient pump flow.
‒ Oil flow to one function is independent of the load pressure of other functions regardless of
sufficient or insufficient pump flow.
• Load-sensing technology for higher efficiency, safety, reduced energy consumption, and longer
system lifetime
• Configurable as an advanced electrical, hydraulic or mechanically operated proportional load-sensing
valve
• Open spool-ends for system integrating mechanical cable or linkage actuation
• Modular design providing a wide range of configuration possibilities
• Up to eight different sections per valve group (maximum flow per section: 240 l/min [63.4 gal/min])
• Can be configured in combination with PVG 32 (with T0) for maximum flexibility (up to 20 basic valve
modules per valve group)
• Optimized return flow characteristics, which minimizes pressure loss
• Low weight
• Compact design and installation
• BSP and UNF connection threads
General Information
• Integrated pilot operated check valves in A and B work ports for low internal leakage
• Integrated pressure compensator
• Interchangeable spools
• Single and Dual Shock/suction valves for A and B ports
• Different interchangeable spool variants
• All versions suitable for mechanical, hydraulic and electrical actuation
• Versions:
‒ PVG100-HF (High Flow) version for less total pressure loss at increased flow
‒ End module version for extra space savings
‒ Open spool-end version for extended mechanical actuation possibilities
Actuation module
The basic module is always fitted with mechanical actuator PVM, which can be combined with the
following as required:
General Information
‒ PVRHH
P
Port 1
12
Pilot
Supply
10
T P
11 2
B A
3
P
T T
B A
P
T T
P301 234
Legend:
7 – Shock and suction valve, PVLP
1 – LS relief valve
8 – Main spool, PVBS
2 – Shuttle valve
9 – Max. oil flow adjustment screws for ports A and B
3 – Pilot operated check valve, POC
10 – Spring 12 or 20 bar
4 – LS line
11 – Pressure matching spool
5 – Logic cartridge for POC
12 – Orifice
6 – Pressure compensator
Example
Pressure comp pressure level 172 bar [2500 psi]
LS standby pressure requirement that delivers the desired flow -20 bar [-290 psi]
Maximum load pressure requirement 152 bar [2210 psi]
Inlet relief pressure setting 152 bar [2210 psi]
Optional PVPC with check valve option may be used in systems where it is necessary to operate the PVG
100 valve by means of the electrical remote control without pump flow.
For additional information about PVPC refer to publicaton 520L0344.
Optional electrically actuated pilot shut off valve PVPP provides additional functional system safety by
removing pilot oil from the electrical actuation or hydraulic actuation system, disabling main spool
actuation. When the PVPP is used with the PVBZ P.O. check valve system it is possible to disable actuation
during mechanical actuation.
cavitation. Optional facilities for dual shock valves for ports A and B provide extra passage area reducing
pressure drop for anti-cavitation applications.
Pilot operated check valve system PVBZ option (6, 8) on ports A and B are uses to reduce the work port to
tank leakage eliminating the need for external actuator load holding in non-critical load holding
applications. All PVG 100 modules contain an integrated T0 drain system to insure optimal performance
for PVBZ and all electrical actuation offerings. T0 is most effective when connected directly to the
hydraulic system reservoir independent of the main Tank return system.
PVG 100 tank modules
Designed for low pressure drop at high return flows all PVT modules include facilities for PVLP shock
valves insuring pressure passage spike protection during pump starvation recovery.
Legend: 7 – LS line
1 – LS relief valve 8 – Logic cartridge for POC
2 – LS connection 9 – Pressure compensator
3 – Priority spool for CF 10 – Shock and suction valve, PVLP
4 – LS connection for steering unit 11 – Main spool, PVBS
5 – Shuttle valve 12 – Max. oil flow adjustment screws for ports A and B
6 –Pilot operated check valve, POC 13 – LS comp (LS signal sent back to compensators)
Q max
Flow
PC setting
0
0 Pressure
P101 968E
P101 967
Most load sensing systems use parallel, closed center, control valves with special porting that allows the
highest work function pressure (LS signal) to feed back to the LS control. Margin pressure is the difference
between system pressure and the LS signal pressure. The LS control monitors margin pressure to read
system demand. A drop in margin pressure means the system needs more flow. A rise in margin pressure
tells the LS control to decrease flow.
LS control with bleed orifice (do not use with PVG valves)
The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control.
Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, for use
with control valves that do not internally bleed the LS signal to tank.
Integral PC function
The LS control also performs as a PC control, decreasing pump flow when system pressure reaches the PC
setting. The pressure compensating function has priority over the load sensing function.
For additional system protection, install a relief valve in the pump outlet line.
Q max
Flow
Remote PC setting
PC setting
0
0 Pressur e P101 969E
P101 966
The remote PC control uses a pilot line connected to an external hydraulic valve. The external valve
changes pressure in the pilot line, causing the PC control to operate at a lower pressure. When the pilot
line is vented to reservoir, the pump maintains pressure at the load sense setting.
When pilot flow is blocked, the pump maintains pressure at the PC setting. An on-off solenoid valve can
be used in the pilot line to create a low-pressure standby mode. A proportional solenoid valve, coupled
with a microprocessor control, can produce an infinite range of operating pressures between the low
pressure standby setting and the PC setting.
Size the external valve and plumbing for a pilot flow of 3.8 l/min [1 US gal/min]. For additional system
protection, install a relief valve in the pump outlet line.
Q max
Flow
PC setting
0
0 Pressur e P101 166E
P101 965
Once the closed center valve is opened, the PC control senses the immediate drop in system pressure
and increases pump flow by increasing the swashplate angle.
The pump continues to increase flow until system pressure reaches the PC setting. If system pressure
exceeds the PC setting, the PC control reduces the swashplate angle to maintain system pressure by
reducing flow.
The PC control continues to monitor system pressure and changes swashplate angle to match the output
flow with the work function pressure requirements.
If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum
displacement. In this condition, actual system pressure depends on the actuator load.
For additional system protection, install a relief valve in the pump outlet line. * Do not use the PVG 32
with bleed down load sense control.
P → A → F (Push-in) P → A → F (Pull-out)
Safety in application
Building in safety
All makes and all types of control valves (including proportional valves) can fail. Thus the necessary
protection against the serious consequences of function failure should always be built into the system.
For each application an assessment should be made for the consequences of pressure failure and
uncontrolled or blocked movements.
To determine the degree of protection that is required to be built into the application, system tools such
an FMEA (Failure Mode and Effect Analysis) and Hazard and Risk Analysis can be used.
W Warning
All makes/brands and types of directional control valves – inclusive proportional valves – can fail and
cause serious damage. It is therefore important to analyze all aspects of the application.
Because the proportional valves are used in many different operation conditions and applications, the
manufacturer of the application is alone responsible for making the final selection of the products – and
assuring that all performance, safety and warning requirements of the application are met.
The process of choosing the control system – and safety levels – is governed by the machine directives
EN 13849 (Safety related requirements for control systems).
Safety in application
Legend:
1 – Main power supply
2 – Emergency stop/man present switch
3 – HMI/Joystick control
4 – Movement detection sensors
5 – Main controller
6 – PVG control valve
7 – Hydraulic deactivation
Safety in application
Failure
Detection Hydraulic deactivation
P301 317
W Warning
It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.
Safety in application
B Error
B Error
E1 E2
2) Alarm
logic
Output
OR
3) Memory
high=on
AND
low=off
Hydraulic
Fault detection output D deactivation
P301 318
System Control Logic e.g. PLUS+1® for signal monitoring and triggering signal for deactivation of the
hydraulic system.
W Warning
It is the responsebilty of the equipment manufacturer that the control system incorporated in the
machine is declared as being in confirmity with the relevant machine directives.
Safety in application
Error
PVEH-DI
AMP connector
2) Fault detection DI-A
DI-B 3) 4) DI-B
DI-A DI Output Delay Memory
US Logic Error
Error
PVEH-DI
AMP connector
Fault detection DI-A
2)
DI-B 3) 4)
DI-A DI Output Delay Memory
US Logic Error
OR
AND
high=on
low=off
Hydraulic
Fault detection output deactivation
P301 319
System Control Logic e.g. PLUS+1® for signal monitoring and triggering signal for deactivation of the
hydraulic system.
W Warning
It is the equipment manufacturers responsibility to ensure that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.
Other non-electrical modules which can be used in connection with hydraulic deactivation at different
levels.
Safety in application
Technical data
1) Intermittent operation: the permissible values may occur for max. 10% of every minute.
2) PVG 100-HF - 350 bar [5075 psi] rated for 250 000 cycles, max. continuous pressure 320 bar [4640 psi].
1) The PVRHH remote control (hydraulic joystick) lever should be connected directly to tank.
Technical data
Technical data
PVEO
Supply voltage UDC rated 12 V DC 24 V DC
range 11 V to 15 V 22 V to 30 V
max. ripple 5%
Current consumption at rated voltage 0.65 A @ 12 V 0.33 A @ 24 V
Input impedance in relation to 0.5 • U DC 12 KΩ
Power consumption 8W
Technical characteristics
The characteristics in this catalog are typical measured results. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] at a temperature of 50°C [122°F] was used.
Pressure relief valve characteristic in PVP Neutral flow pressure in PVP, open center
The pressure relief valve is set at an oil flow of 15 l/min [4 US gal/min]. Setting range: 30 to 350 bar [435 to
5075 psi]
Open center flow rating
The flow rating of the different main spools will depend on the standby pressure available. In open center
systems, the standby pressure equals the pressure drop P–>T, see the diagram above. A pump flow of 150
l/min led to tank across the pressure adjusting spool, will generate a standby pressure of app. 15 bar (PVP
with 12 bar spring). The according main spool flow ratings will correspond to the curves.
For PVPs with a 20 bar spring, the standby pressure available will be 20 bar or higher. Hence the
according main spool flow ratings will correspond.
Closed center flow rating
The flow rating of a the different main spools, PVBS, is dependent upon the Load Sense margin (pump
margin pressure). The nominal flows specified for each PVBS is specified at 15 bar [218 psi] Ls margin
pressure. If Ls margin is increased above 15 bar [218 psi], the PVBS will deliver more flow then the
nominal rating. The following curves show the relationship between Ls margin and work port flow.
Flow vs. LS margin @ maximum spool shift
Technical characteristics
C Caution
Because of flow forces, cylinder differential areas, Danfoss recommends Ls margins under 25 bar [360 psi].
As noted above, work port flow is dependent upon the Ls margin set on the pump. PC pumps maintain a
constant discharge pressure which is equal to the PC setting on the pump. Hence the Ls margin for PC
pumps can be thought of as the difference between the PC setting and the load pressure. Therefore work
port flow will change with load pressure, thus, pressure compensated flow will not be obtained.
PVB, basic module
Pressure drop PVB at max. main spool travel
Dp Dp
psi bar
PVG 100 A/B T max spool travel
900 60
150
800
50 180
700
40 210
600 40
65 130
500
30 100 240
400
300 20
200
10
100
0 0 Q A/B
40 80 120 160 200 240 280 320 360 400 440 l/min
Q A/B
0 40 50 60 70 80 90 105
US gal/min
V310203.B
Technical characteristics
500 40
0 0 Q A/B
0 10 20 30 40 50 l/min
Q A/B
0 2 4 6 8 10 12 14 US gal/min
V310204.A
Set pressure difference between pump pressure and LS signal = 20 bar [290 psi] measured at the P-port
of the valve.
Technical characteristics
Oil flow as a function of spool travel for spools A to F - 15 bar [218 psi]
Set pressure difference between pump pressure and LS signal = 15 bar [218 psi] measured at the P-port
of the valve.
The shock valve PVLP is designed to absorb shock effects. Consequently, it should not be used as a
pressure relief valve. PVLP is set at an oil flow of 10 l/min [2.6 US gal/min].
Technical characteristics
Hydraulic systems
240
240 160
Inlet LS T
Relief
setting
PVLP setting
in PVT should
250 be a minimum
of 30 bar above
setting on the
pump or external
relief valve
300
T0 Pgage Pp
P
270 bar
Hydraulic systems
Electrically actuated PVG 100, variable displacement pump, PVB 100 with integrated pilot operated check valves
A B A B A B A B
P301 232
Hydraulic systems
Electrically actuated PVG 100/32, fixed displ. pump, PVB 100/32 with integrated pilot operated check valves
Oil
The main duty of the oil in a hydraulic system is to transfer energy; but it must also lubricate the moving
parts in hydraulic components, protect them against corrosion, and transport dirt particles and heat out
of the system. It is therefore important to choose the correct oil with the correct additives. This gives
normal operation and long working life.
Mineral oil
For systems with PVG 100 valves Danfoss recommends the use of mineral-based hydraulic oil containing
additives: Type HLP (DIN 51524) or HM (ISO 6743/4).
Non-flammable fluids
Phosphate-esters (HFDR fluids) can be used without special precautions. However, dynamic seals must be
replaced with FPM (Viton) seals. Please contact the Danfoss Sales Organization, if the PVG 100 valve is to
be used with phosphate-esters.
The following fluids should only be used according to agreement with the Sales Organization for
Danfoss:
• Water-glycol mixtures (HFC fluids)
• Water-oil emulsions (HFB fluids)
• Oil-water emulsions (HFAE fluids)
Biodegradable oils
PVG 100 valves can be used in systems with rapeseed oil.
The use of rapeseed oil is conditioned by:
• complying with the demands on viscosity, water content, temperature and filtering etc. (see chapters
below and technical data page 7).
• adapting the operating conditions to the directions of the oil supplier.
Before using other biodegradable fluids, please consult the Danfoss Organization.
Filtration
Effective filtration is the most important precondition in ensuring that a hydraulic system performs
reliably and has a long working life. Filter manufacturers issue instructions and recommendations. It is
advisable to follow them.
System filters
Where demands on safety and reliability are very high a pressure filter with bypass and indicator is
recommended. Experience shows that a 10 µm nominal filter (or finer), or a 20 µm absolute filter (or finer)
is suitable. It is our experience that a return filter is adequate in a purely mechanically operated valve
system.
The fineness of a pressure filter must be selected as described by the filter manufacturer so that a particle
level of 23/19/16 is not exceeded.
The filter must be fitted with pressure gauge or dirt indicator to make it possible to check the condition of
the filter.
In systems with differential cylinders or accumulators the return filter must be sized to suit the max.
return oil flow. Pressure filters must be fitted to suit max. pump oil flow.
Internal filters
The filters built into PVG 100 are not intended to filter the system but to protect important components
against large particles. Such particles can appear in the system as a result of pump damage, hose fracture,
use of quick-couplings, filter damage, starting up, contamination, etc.
The filter in the electrical actuator PVE protecting the solenoid valves has a mesh of 150 µm.
Bursting pressure drop for internal filters is 25 bar [360 psi].
P301 065
Standard Mounted Work Section
Standard mounting is defined as installing the PVM on the “A” port side of the PVB. Because of this, the
PVE or PV cover (PVH, PVMD, PVMR, PVMF or PVHC) would be on the “B” port side of the valve.
Option mounting – the PVM on the “B” port side of the PVB
B A
LS holes
P301 066
Option mounting is defined as installing the PVM on the “B” port side of the PVB. Because of this, the PVE
or PV cover (PVH, PVMD, PVMR, PVMF or PVHC) would be on the “A” port side of the valve.
The PVBS in PVG 100 are not symmetric. Because of this the “Load Sense” (Ls) holes in the PVBS main
spool must be installed so that they are on the “B” port side of the PVB.
Standard mounting spool (upper PVBS) vs. Option mounting spool (below PVBS)
LS holes
P301 050
Before determining spool part numbers, determine whether the section will be standard or option
mounted. Standard and Option mounting only applies to a work section. Standard and option mounted
section can be used together in the same stack.
PVPF (Open Center) Inlet Modules - for Pumps with Fixed Displacement
PP
TP PP LS LS T0
PVPP
P301 054
PVPVP, Closed Center Priority Side Modules - for Pumps with Variable Displacement
PVPVM, Closed Center Mid Inlet Modules - for Pumps with Variable Displacement
* requires two PVAS kits
12 V 24 V 12 V 24 V 12 V 24 V
PVEO ON/OFF 157B4216 157B4228 157B4901 157B4902 157B4291 157B4292
ON/OFF with ramp 157B4217 157B4229 157B4903 157B4904 - -
ON/OFF anodized 157B4266 157B4268 - 157B4272 - -
11 - 32 V 11 - 32 V 11 - 32 V
PVEA Standard, active fault monitoring - 157B4734 157B4792
Standard, passive fault monitoring - 157B4735 -
PVEA-DI Standard, active fault monitoring - 157B4736 157B4796
Standard, passive fault monitoring - 157B4737 -
PVEH Standard, active fault monitoring 157B4032 157B4034 157B4092
Standard, passive fault monitoring 157B4033 157B4035 157B4093
Float, passive fault monitoring - - 157B4392
Standard, passive, anodized - 157B4073 -
Float, active fault monitoring 157B4332 157B4034 -
PVEH-DI Standard, active fault monitoring - 157B4036 157B4096
Standard, passive fault monitoring - 157B4037 -
B
TP Pp LSLScompT0
P301 134
B
TP PP LS LScomp T0
P301 135
bar psi
PVLP PVLP 32 460 157B2032
Shock and anti-
50 725 157B2050
cavitation valve
1 2 A
(Not adjustable) 63 914 157B2063
80 1160 157B2080
B
TP PP LSLScomp T0
P301 133
100 1450 157B2100
125 1813 157B2125
140 2031 157B2140
150 2175 157B2150
160 2320 157B2160
175 2538 157B2175
190 2755 157B2190
210 3045 157B2210
230 3335 157B2230
240 3480 157B2240
250 3625 157B2250
265 3843 157B2265
280 4061 157B2280
300 4351 157B2300
320 4641 157B2320
350 5075 157B2350
PVT G 1¼ 161B2505
Without active elements
15∕8-UNF 161B2525
With T-port
PVLP shock valve facility
With LX connection G1/4
[ 9/16 in – 18 UNF]
* Must use T0 equipped PVG32 Modules, for details see Danfoss Technical Information Basis Modules
PVBZ, 520L0721.
PVG 100 PVSI / PVT, Assembly Kit
1 PVB 2 PVB 3 PVB 4 PVB 5 PVB 6 PVB 7 PVB 8 PVB 9 PVB 10 PVB
Tie bolts and seals 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009
PVG 32 Basic Modules with T0, PVBZ (Compatible with PVG 100)
T P LS Pp T0 157-586.13
PVG 32 Basic Modules with T0, PVB (Compatible with PVG 100)
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Closed Neutral Position 161B7022 161B7023 161B7024 161B7025 161B7026 161B7027
Standard Mount
Option Mount 11013079 11013080 11013081 11013082 11013083 11013084
P301 058
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3-position, Throttled Open Neutral Position 161B7122 161B7123 161B7124 161B7125 161B7126 161B7127
Standard Mount
Option Mount 11013085 11013086 11013087 11013088 11013089 11013090
P301 059
4-way, 4-position, Closed Neutral Position, Electric float 161B7622 161B7623 161B7624 161B7625 161B7626 161B7627
P –> A –> F
Standard Mount
Option Mount 11013091 11013092 11013093 11013094 11013095 11013096
P301 060
4-way, 3-position, Throttled Open Neutral Position 11016865 11016866 11016867 11016868 11016869 11016870
Electric Float P –> A –> F
Standard Mount
Option Mount 11016871 11016872 11016873 11016874 11016875 11016876
P301 060
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Closed Neutral Position 161B9522 161B9523 161B9524 161B9525 161B9526 161B9527
Standard Mount
Option Mount 11013097 11013098 11013099 11013100 11013101 11013102
P301 058
4-way, 3-position, Throttled Open Neutral Position 161B9622 161B9623 161B9624 161B9625 161B9626 161B9627
Standard Mount
Option Mount 11013103 11013104 11013105 11013106 11013107 11013108
P301 059
Spools for Friction Detent, PVMR (not compatible with PVBZ 100)
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3-position, Throttled Open Neutral Position 161B9732 161B9733 161B9734 161B9735 161B9736 161B9737
Standard Mount
Option Mount 11013109 11013110 11013111 11013112 11013113 11013114
P301 061
Spools for Mechanical Float position, PVMF (not compatible with PVBZ 100)
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Throttled Open Neutral Position 161B9822 161B9823 161B79824 161B9825 161B9826 161B9827
Standard Mount
Option Mount 11013115 11013116 11013117 11013118 11013119 11013120
P301 062
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Closed Neutral Position 11016852 11016853 11016854 11016855 11016857 11016858
Standard Mount
Option Mount 11016859 11016860 11016861 11016862 11016863 11016864
P301 058
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3-position, Throttled Open Neutral Position 11116606 11116607 11116608 11116609 11116610 11116611
Standard Mount
Option Mount - - 11090529 11090653 - -
P301 059
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Throttled Open Neutral Position 11116612 11116613 11116614 11116615 11116616 11116617
Standard Mount
P301 059
Standard Spools (Electrical and Mechanical Actuation), Full Open A/B → T and Neutral; Progressive Flow Characteristics
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Open Neutral Position 11121597 11121598 11121599 11121600 11121601 -
Standard Mount
Standard Spools (Hydraulic and Mechanical Actuation), Full Open A/B → T and Neutral; Progressive Flow Characteristics
Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure)
l/min [US gal/min]
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-way, 3 position, Open Neutral Position 11121602 11121603 11121604 11121605 11121606 11005747
Standard Mount
Exposed Spools
The following spools are available with an exposed tang for mechanical actuation. These spools are only
available for standard mounting.
020065
PVB part number
includes seal plate
P301 136
A B C D E F
40 [10.6] 65 [17.2] 100 [26.4] 130 [34.4] 150 [39.6] 180 [47.6]
4-Way, 3-Position, Closed Neutral Position
Standard Mount 11051695 11051696 11051697 11051698 11051699 11051700
P301 138
P301 139
Dimensions
P301 064
Dimensions
Legend:
P: Pump port: G1 [15∕16 in-12UNF]
Pp accumulator: G¼ [9∕16 in-18UNF] L: LS relief valve
T0 and LS: G¼ [9∕16 in-18UNF] G: PVPE unloading valve
P and Pp gauge: G¼ [9∕16 in-18UNF] H: PVPP pilot shut off valve
K: LX: G¼ [9∕16 in-18UNF] J: Mounting thread; M12 x 14 mm deep
F: Tank port: G1 [15∕16 in-12UNF]
Dimensions
To avoid spool bind or leakage between sections caused by uneven mounting surfaces it is
recommended to only use 3 of 4 mounting holes provided.
Dimensions
Dimensions
Legend:
E: Port A and B PVB 100; G¾ [11∕16 inin - 12 UNF]
Pp accumulator: G¼ [9∕16 in-18UNF]
H : Port A and B PVB 32; G½ [7∕8 in - 14 UNF]
T0 and LS: G¼ [9∕16 in-18UNF]
I : Mounting thread ; M8 x 15 mm deep [5∕16 in - 18
P and Pp gauge: G¼ [9∕16 in-18UNF] UNC]
D: Pump port; G1 [15∕16 in-12UNF] J: Mounting thread; M12 x 14 mm deep
F: Tank port; G1¼ [15∕8 in - 12 UNF] L: LS relief valve
1 PVB 2 PVB 3 PVB 4 PVB 5 PVB 6 PVB 7 PVB 8 PVB 9 PVB 10 PVB
L1 mm 80 128 176 224 272 320 368 416 - -
[in] [3.15] [5.04] [6.93] [8.82] [10.71] [12.60] [14.49] [16.38] - -
L2 mm 100 148 196 244 292 340 388 436 484 532
[in] [3.94] [5.83] [7.72] [9.61] [11.50] [13.39] [15.28] [17.16] [19.05] [20.94]
L3 mm - 245 293 341 389 437 485 533 581 629
[in] - [9.64] [11.54] [13.43] [15.31] [17.20] [19.09] [20.98] [22.87] [24.76]
Dimensions
Legend:
K: LX connection G¼ [9∕16 in - 18 UNF]
CF: G½ [¾ in - 16 UNF]
Lst: LS for steering unit; G¼ [9∕16 in - 18 UNF]
LS: G¼ [9∕16 in - 18 UNF]
E: Port A and B PVB 100; G¾ [1 1∕16 in - 12 UNF]
P gauge: G¼ [7∕16 in - 24 UNF]
H: Mounting thread M12 x 14 mm deep
T0 port: G¼ [9∕16 in - 18 UNF]
J: Mounting bracket with holes for M12 screws
Pp gauge: G¼ [7∕16 in - 24 UNF]
M: LS relief valve
P pump: G¾ [1 1∕16 in - 12 UNF]
F: G¼ [1 1∕16 in]
Dimensions
Dimensions
131 ± 2.5
[5.16 ± 0.1]
To port
(9/16-18 SAE)
161 ± 3
[6.34 ± 0.12] 12 ± 2
Work Ports [0.47 ± 0.08]
Outlet ports
Inlet Port (1 5/8-12 SAE) 201
(247) (1 5/16-12 SAE) REF.
[9.72] 175
REF.
24.5 ± 2.0 [0.96 ± 0.08]
93 ± 2 118.0 ± 2.5
[3.66 ± 0.08] [4.65 ± 0.1]
62.5 ± 2
[2.46 ± 0.08]
92.5 12.5 ± 2 [0.49 ± 0.08]
[3.64]
(60)
(83)
[2.36]
[3.27]
(51.3) [2.02]
(44)
39 ± 2 [1.53 ± 0.08]
[1.73]
173 ± 3 87 ± 2 [3.43 ± 0.08]
[6.81 ± 0.12] 135 ± 2.5 [5.31 ± 0.1]
183 ± 2.5 [7.2 ± 0.1]
235 ± 3 [9.25 ± 0.12]
(268) [10.55]
224 ± 2.5 [9.6 ± 0.1]
LX Ports
(9/16-18 SAE)
P301 140E
0 0 0 PVPP
PVPD
PVPC 1-12
16
PVBZ PVB
a
13 PVTI
c PVMD, PVH
PVM
PVT
PVLP/A
15
Assembly kit 157-699.11
PVP 100, Pump Side Module – Open center, PVPF with pilot supply (excludes PVPD/PVPE)
Port Open center, PVPF with pilot supply
for PVE for PVE and facility for pilot for PVH/PVHC for PVH/PVHC and facility for
shut off pilot shut off
PVP 100, Pump Side Module – Closed center, PVPV with pilot supply
Port Closed center, PVPV with pilot supply
for PVE for PVE and facility for PVE with for PVH/PVHC for PVH/PVHC and for PVH/PVHC with
for pilot shut-off integrated priority facility for pilot integrated priority
function shut-off function
P=G1 161B5111 161B5141 - 11013069 11013075 -
P = 1⁵⁄₁₆ UNF 161B5511 161B5541 - 11013070 11013076 -
P = G ¾; T = G 1 - - 161B5211 - - 11013077
P = G 1¹⁄₁₆ UNF; - - 161B5611 - - 11013078
T = 1⁵⁄₁₆ UNF
Weight 8.5 kg [12.3 lb]
PVP 100, Pump Side Module – Closed center, PVPVM with pilot supply
Port Closed center, PVPVM with pilot supply
Not available for PVPV 157B5211 and 157B5611, (for details see catalog, 520L0344)
* Anodized 157B3184
** Cast iron
Assembly Kit PVG100 for PVB End module (must be used with bottom tank ported PVB)
Description Code No.
1 PVB 2 PVB 3 PVB 4 PVB 5 PVB 6 PVB 7 PVB 8 PVB 9 PVB 10 PVB
PVB’s 157B8000 157B8001 157B8002 157B8003 157B8004 157B8005 157B8006 157B8007 157B8008 157B8009
Weight [kg [lb] 0.1 [0.2] 0.15 [0.3] 0.25 [0.6] 0.3 [0.7] 0.4 [0.9] 0.45 [1] 0.5 [1.1] 0.6 [1.3] 0.65 [1.4] 0.7 [1.6]
Order specification
An order form for Danfoss PVG 100 hydraulic valve is shown on the next page. The form can be obtained
from the Danfoss Sales Organization.
Both the module selection chart on the previous pages and the order form are divided into fields 0, 1-10,
11, 12, 13, a, b, and c.
Each module has its own field:
0: Pump side module PVP
Plug for external pilot oil supply PVPC
Electrical unloading valve PVPE
Electrical pilot shut off valve PVPE
1-10: Basic valves PVB
13: Main spool PVBS
a: Mechanical actuator PVM
c: Cover for mechanical actuation PVMD
Cover for hydraulic actuation PVH
Electrical actuators PVE
b: Shock and suction valve PVLP
Suction valve PVLA
11: End plate PVSI
Tank module PVT
Interface module PVTI
12: Assembly kit PVAS
Please state
Specification sheet
Specification Form
• Integrated Systems We offer expert worldwide support for our customers, ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also provide
• Joysticks and Control comprehensive global service for all of our components.
Handles
• Microcontrollers and Please contact the Danfoss Power Solution representative nearest you.
Software
• Open Circuit Axial Piston
Pumps
• Orbital Motors
• PLUS+1® GUIDE
• Proportional Valves
• Sensors
• Steering
• Transit Mixer Drives
Comatrol
www.comatrol.com
Local address:
Schwarzmüller-Inverter
www.schwarzmueller-
inverter.com
Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss
Power Solutions
Danfoss Danfoss Danfoss (Shanghai) Co. Ltd.
Power Solutions US Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.