DIVISION 14 – Conveying Equipment

Hydraulic Home Elevator


When it comes to residential elevator systems, hydraulic
drives are a popular choice for homeowners looking for
quality, safety, and the ‘quietest’ ride.
When it comes to residential elevator systems, hydraulic
drives are a popular choice for homeowners looking for
quality, safety, and the ‘quietest’ ride.
Hydraulic home elevator systems utilize a ram or piston to
raise and lower the car by filling or releasing fluid into an
airtight cylinder. With more standard features and custom
options than any other elevator on the market today, Symmetry’s Hydraulic Drive Residential
Elevator system is the industry leader.
Unique in the market, no other company offers emergency battery-operated lowering, COP and
hall stations digital position indicators, custom wood sills and energy-efficient LED lighting as
standard features.
This drive system accommodates up to six stops, 50’0" of travel and is equipped to hold up to
1,000 pounds.

Standard Features

• Travel: Maximum of 50’0" (minimum 12” between stops)


• Speed: 40 feet per minute
• Rated Capacity: 1000 pounds
• Overhead Minimum of 7’10" (94”) with remote controller*
• Pit depth: 6” minimum (8” preferred)
• Two stops
• Single opening
• Three-year limited parts warranty

Mechanical Equipment
• Modular 6-1/4 pound T-rail structure
• Car frame assembly
• 208/230 volts alternating current, 60 hertz, 30 amp single phase power supply for motor
controller
• 120 volts alternating current, 60 hertz, 15 amp single phase power supply for lighting
• 208/230, 3 horsepower submersed motor with 2-speed valve assembly (1750
revolutions per minute / 17 full-load-amperage) - manual down valve for emergency
lowering
• Screw pump (300 micron screen)
• Positive pressure switch
• Code compliant electrical disconnects included*

Safety Features

• Slack rope safety device


• Motor controller supply disconnects (located in controller)
• Car light supply disconnects (located in controller)
• Rupture Valve (Type “C” Safety)
• Pit stop switch
• Car top stop switch
• In-car emergency stop switch and alarm
• Safety switch for car gate(s)
• Battery back-up emergency car lights and alarm
• Electromechanical hoistway door interlocks (doors by others)
• Light curtain monitoring the car entrance

Controls

• Programmable Logic Controller (PLC)


• Non-selective collective automatic operation
• S.M.A.R.T. System (Self-Monitoring Alert Response Technology)*
• Car Operating Panel (COP) with LED floor position indicator; available in multiple finishes
• Recessed phone box in multiple finishes (phone jack included)
• Hall stations with call button and LED floor position indicator; available in multiple
finishes
• Automatic car lighting
• Single floor designated car homing
• Uninterruptible Power Supply (UPS) for car lowering and automatic gate operation (if
provided) in the event of power failure*

Car Features

• Car size up to 15 square feet


• 7’0” interior car height
• Birch, Oak, or Maple flat veneer interior walls with matching ceiling*
• Matching wood handrail
• Matching wood car sill*
• Unfinished plywood floor with sill set for .75” (flooring by others)
• 2 energy saving recessed LED lights with black trim rings*
• 7’0” vinyl laminate accordion gate (light oak, dark oak, birch, white, chalk or antique
white)

Optional Features

• Up to six stops
• Single automatic push button operation
• Custom car size up to 18 square feet**
• Custom car heights
• Shaker or Recessed panel car with flush ceiling
• Shaker or Recessed panel car with matching ceiling
• Raised panel car with matching ceiling
• 4 recessed LED lights with black, brass, nickel or bronze trim rings*
• Factory finished car
• Polished stainless steel, polished or brushed brass, black, vintage bronze and oil rubbed
brass fixtures (including COP, phone box, hall calls, and handrail)
• COP with integrated keypad phone*
• Custom wood interiors
• Custom factory finishes (antiqued, distressed, & crackle)*
• Green material alternatives and finishes for car interiors*
• Symmetry Safety 3 Panel Car Door
• Two & Three speed car or car and landing doors
• Wrap around car door
• Enterprise collapsible gate
• Hardwood veneer accordion gate
• Clear panel accordion gate
• Automatic car gate/door operator (not available on Enterprise collapsible gate)
• .75” finished or unfinished factory installed hardwood car flooring
• Factory flooring insert for 1/4” flooring by others
• Buffer springs (requires minimum of 10” pit depth)
• Key switch for COP and hall stations
• 750 pound car capacity
• Accordion gates will have bronze hardware except on white, chalk, or antique white
gates. Acrylic gates will have clear hardware when stainless
or black fixtures are provided.

Symmetry Elevating Solutions - Vertical Platform Lift -


Enclosed Lift Plexi-glass
Vertical Platform Lift - Enclosed Lift Plexi-glass
The enclosed plexi-glass vertical platform lifts are used in
the same way as the enclosed lift, with plexi-glass infill
enclosure wall panels.
Standard Features

• 750 to 1,000-pound capacity


• Speed: 10 feet per minute
• Motor: 1 horsepower, 115 volt (Acme Screw Drive)
• Lifting height: up to 60” for commercial applications and 168" for residential
applications
• Steel construction with electrostatic, powder-coated finish
• A.W.A.R.E. system (Active Wiring, Accessories, Relay, and Electronics Diagnosis)*
• Constant-pressure up/down control switch installed on the platform
• Constant-pressure elevator-style hall call control station provided at each landing

Drive Options

• Acme Screw Drive: 10 feet per minute, 1 horsepower, 115 volt


• Accelerated Acme Screw Drive: 20 feet per minute, 1 horsepower, 115 volt
• Hydraulic Drive: 17-20 feet per minute, 2 horsepower, 115 volt

Optional Features

• Low profile Carriage: 1 1/2" pit depth*


• Remote mounted controller*
• 230 volt motor
• ADA phone for both indoor and outdoor models
• Emergency lights
• Key switch to lock platform and landing controls
• Stationary ramp
• Full-speed battery backup
• Power gate operators*
• Power ventilation system
• Slant roof/dome enclosure

Safety Features

• Non-skid platform surface (black)


• Obstruction safety panel under platform (when not installed with a runway enclosure)
• Alarm and emergency stop switch
• Grab rail
• Landing interlocks keep door closed/locked when the platform is at another landing
• Upper final limit switch

Clear Platform Sizes

• 36”W x 48”D
• 36”W x 54”D
• 36”W x 60”D
• 42”W x 60”D
• Custom sizes available
Enter/Exit Configurations

• Straight-through
• 90° adjacent
• Same side

Gate/Door Options

• 42” platform gate**


• 42” landing gate**
• 80” landing gate**
• Non-fire-rated red oak door‡
• Fire-rated steel door

Enclosure Options

• Metal Infill enclosure wall panels


• Plexi-glass infill enclosure wall panels
PART 1 GENERAL
1.01 SECTION INCLUDES:
A. UL – Unenclosed.
B. SL – Shaftway.
C. EL – Enclosed.
D. Hybrid (Elevator Style Lift).
1.02 RELATED SECTIONS:
A. Section 00330 - Cast–in-Place Concrete: Concrete shaftway and anchor placement.
B. Section 04800 - Masonry Assemblies: Masonry shaftway and anchor placement.
C. Section 06100 - Rough Carpentry: Blocking in framed construction for lift attachment.
D. Section 09260 - Gypsum Board Assemblies: Gypsum shaft walls.
E. Division 16 – Electrical: Dedicated telephone service and wiring connections.
F. Division 16 – Electrical: Lighting and wiring connections at top of shaft.
G. Division 16 – Electrical: Electrical power service and wiring connections.
1.03 REFERENCES:
A. This lift shall be designed and tested in accordance with ICC/A117.1, NEC and ASME
A18.1 Guidelines.
B. All designs, clearances, construction, workmanship and installation shall be in
accordance with the requirements and code adopted by the authority having jurisdiction.
C. This platform lift shall be subject to local, city and state approval prior to and following
installation.
1.04 SUBMITTALS:
A. Submit under provisions of Section 01300.
B. Product Information:
1. Submit manufacturer’s installation instructions including preparation and equipment
handling requirements.
2. Show maximum and average power necessity.
C. Drawings shall include:
1. Typical details of assembly, erection and anchorage.
2. Wiring diagrams for power, control, and signal systems.
3. Complete layout with location of equipment.
D. Manufacturer’s Certificates must certify products meet or exceed specified
requirements.
1.05 QUALITY ASSURANCE:
A. Manufacturer: Company shall contain personnel with not less than ten (10) years of
experience in the design and fabrication of vertical wheelchair lifts.
B. Technical Services: Manufacturer and authorized dealer shall work with architects,
engineers and contractors to adapt the vertical wheelchair lift to the design and structural
requirements of the building, site, and code requirements.
C. Unit must be assembled and tested in factory before shipment. Vertical Wheelchair Lift
equipment shall meet or exceed the National and Local standards.
D. All load ratings and safety factors shall meet or exceed those specified by all governing
agencies with jurisdiction and shall be certified by a professional engineer.
E. Installer Qualifications: Factory trained and licensed to install equipment of this scope,
with evidence of experience with specified equipment. Installing company shall have qualified
people available to ensure fulfillment of maintenance and callback service.
1.06 REGULATORY REQUIREMENTS
A. Provide Vertical Wheelchair Lift complying with:
1. ASME A18.1 – Safety Code for Platform Lifts
2. ASME A17.1 – Safety Code for Elevators and Escalators
3. ASME A17.5 – Elevator and Escalator Electrical Equipment
1.07 DELIVERY, STORAGE, AND HANDLING:
A. Products stored in manufacturer’s unopened packaging until ready for installation.
B. Components stored off the ground in a dry covered space, protected from weather
conditions.
1.08 PROJECT CONDITIONS:
A. Vertical Wheelchair Lift not to be used for hoisting materials or personnel during
construction.
1.09 WARRANTY:
A. Unit shall have a FOUR (4) year limited parts warranty covering replacement of defective
parts of the basic unit, including all electrical and drive system components, at no cost. Labor
costs required to replace parts is not included. Preventative maintenance agreement required.
B. Extended Warranty: Provide an extended manufacturer’s warranty covering the vertical
wheelchair lift components for the following additional period beyond the initial standard four
year warranty. Preventative Maintenance every six (6) months required.
1. 3 years (7 years total).
2. 6 years (10 years total).
3. Lifetime.
1.10 MAINTENANCE
A. Maintenance of the vertical wheelchair lift unit shall consist of regular cleaning,
inspection, and adjustment of the unit at intervals not longer than every six (6) months. Rule
10.2.1 of ASME A18.1 required all Vertical Wheelchair Lifts to be inspected every six (6) months.
Provide maintenance contract for the following years:
1. 4 years.
2. 7 years.
3. 10 years.
4. Lifetime.
PART 2 PRODUCT
2.01 MANUFACTURER:
A. Acceptable Manufacturer: Symmetry Elevating Solutions
Email: customerservice@symmetryelevator.com
Toll Free: 877-568-5804
Website: www.symmetryelevators.com
B. U.S. OWNED AND OPERATED: Manufacturer must registered U.S. owned company and
manufacturing operation located in the United States of America – America Owned, American
Operated.
C. No Substitutions Allowed.
D. Request for substitutions will be considered in accordance with provisions of section
01600.

2.02 UNENCLOSED VERTICAL WHEELCHAIR LIFT:


A. General Description: The Unenclosed vertical platform lift is designed for lifting heights
up to 60”. Versatile enough for indoor or outdoor use, this unit can either be mounted directly
to the floor or in a shallow pit.
B. Capacity:
1. 750 lbs.
C. Lifting Height
1. Up to 42 inches.
2. Up to 60 inches.
3. Up to 72 inches (Residential Application only).
4. Up to 96 inches (Residential Application only).
5. Up to 120 inches (Residential Application only).
6. Up to 144 inches (Residential Application only).
7. Up to 168 inches (Residential Application only).
D. Platform Size:
1. 36” W x 48” D
2. 36” W x 54” D
3. 36” W x 60” D
4. 38” W x 54” D
5. 42” W x 60” D
6. Custom Size _____ W x _____ D
E. Platform Configuration:
1. Straight Through.
2. Enter/Exit same side.
3. 90 Degree.
F. Gate/Door:
1. Gate Height: 42 inches.
2. Platform Gate: Travels with platform and opens at lower landing.
3. Upper Landing Gate: Detached, freestanding type.
G. Landing Openings:
1. Lower Landing: Door.
2. Lower Landing: Gate.
3. Upper Landing: Door.
4. Upper Landing: Gate.
H. Door Construction:
1. 42 inch tall Landing/Platform Gate.
2. 80 inch tall gate.
a. Lower Landing
b. Upper Landing
3. A CSD-Rated (R) Fire Rated (B Label) flush mounted steel door and frame shall be
provided. Door shall include wire mesh vision panel with delay action door closure, dead latch,
dummy trim door handle and electric strike.
4. A CSD – Non-Rated (NR) Low profile flush mounted steel door and frame shall be
provided. Door shall include mesh vision panel with delay action door closure, dead latch,
dummy trim door handle, lock plate cover and electric strike.
a. Panels of 16 gauge galvanized steel.
b. Panels of clear Plexiglas.
c. Panels of bronze Plexiglas.
d. Panels of ¼ inch laminated safety glass.
5. A CWS – Flush mounted, solid core oak laminated door and (oak) frame shall be proved.
Door shall include mesh vision panel with delay action door closure, dead latch, dummy trim
door handle, lock plate cover and electric strike.
6. Flush mounted, 42 inches high, solid core oak laminated gate and (oak) frame shall be
provided at the upper landing. Gate includes spring hinges, dead latch, dummy trim gate
handle, lock plate cover and electric strike.
I. Power Gate Operators:
1. Location:
a. Platform Gate.
b. Upper landing Gate.
2. “Smart Operation” Power Gate Operator: Allows operator to open, stop at obstruction,
close and remain in NORMAL operation mode. Operator will not stop mid cycle and leave unit
non-operational.
3. Opens automatically when platform arrives at landing, pressing the call button, or
pulling on the gate.
4. ADA compliant.
5. Low voltage, 24 VDC.
J. Screw Drive:
1. Drive Type: Acme Screw Drive.
2. Travel speed: 10 fpm.
3. Motor: 1HP, 115 volt, 1 phase.
4. Power Supply:
a. 115 VAC, 30 Amp, Single Phase.
b. 230 VAC, 15 Amp, Single Phase.
5. Battery Powered Emergency Lowering:
a. Battery powered platform lowering device which automatically activates in the event of
power failure.
b. Capable of running lift up and down for a minimum of 5 trips with rated load.
6. The drive mechanism shall be a stationary nut on a rotating 1” diameter Acme screw
with a secondary safety nut.
K. Hydraulic Drive:
1. Drive Type: Chain Hydraulic.
2. Travel speed: 17 to 20 fpm.
3. Motor: 2HP, 24 VDC. AC powered primary drive.
1. Power Supply: 115 VAC, 15 Amp, Single Phase
a. Powered by continuous building mains converted to 24 VDC equipped with auxiliary
battery power system. Battery power system capable of running lift up and down for a
minimum of 5 trips with rated load.
4. Standard on board 24 VDC standby battery power to operate the lift up and down in the
event of a power failure.
5. Drive mechanism shall be a 1:2 #60 roller chains hydraulic equipped with a type “A”
instantaneous slack chain safety device.
6. Hydraulic connections shall be metal and have rated pressure that withstands the
working pressure with a 5 times safety factor.
7. Bi-directional leveling, factory supplied oil collection means as required by A18.1-
8.1.4.7, Angled pressure gage standard, roller bearing sprockets, vibration isolated hydraulic
power unit.
L. Lift Components:
1. Symmetry Elevating solutions PLC Controller with self diagnostics and digital display.
A.W.A.R.E. System (Active Wiring, Accessories, Relay & Electronics Diagnosis System) generates
on-demand diagnostic codes identifying trouble or maintenance codes.
2. The Drive Tower support shall be a combination 7 gauge C Channel, 7 gauge interface
plates and 16 gauge exterior skin.
3. Platform shall be constructed of 12-gauge minimum hot rolled steel. If unit is not
installed in a 3-inch pit, an auto-retracting ramp, or stationary ramp, shall be provided that
extends to meet lower landing.
4. Platform side panels shall be 42” high, Side panel framework shall be a minimum of 1”x1
½” steel. Solid infill panels shall be a minimum of 18 gauge steel.
5. Carriage platform supports shall be a minimum of ½” steel. Solid infill panels shall be a
minimum of 18 gauge steel.
6. Elevator style (Nylon) rollers shall be used for axial carriage guidance and wear pads
shall be used for horizontal stability.
7. Loaded fasteners shall be grade eight or higher. Locking fasteners shall be used in all
critical locations.
8. Outdoor Protection: Lift shall include modifications recommended by manufacturer for
reliable performance in extreme outdoor environment.
M. Platform Base & Frame Installation:
1. Pit Mount: (recess application) Level pit floor slab recessed min. 3” by others as outlined
on site specific show drawings. This application does not require ramp and allows for smooth
transition from landing into lifting equipment.
2. Floor Mount: (non-recess application) If unit is not installed in a min. 3” pit, an auto-
retracting ramp shall be provided that extends to meet the lower landing. Optional fixed
mounted ramp is available. (verify clear landing requirements if fixed ramp selected)
a. Platform Access Ramp: 12 gauge galvanized steel plates; slip resistant surfaces.
1. Ramp: Stationary type.
2. Ramp: Automatic folding type.
3. Carriage to be equipped standard with articulating base and carriage design, which
allows the carriage to be folded to reduce the tower and carriage width to 21” for ease of
installation, without removal of the carriage.
N. Platform Controls:
1. Constant pressure up/down control switches shall be installed on the platform. All
switches meet IP66 requirements.
2. An illuminated emergency stop switch / Audible alarm switch shall be provided on the
car as a means of signaling for assistance in the event of an emergency.
3. Keyless operation.
4. Keyed operation.
5. Emergency Telephone:
a. Wiring Only.
b. Platform shall be equipped with a telephone meeting the following requirements:
1. ADA compliant.
2. Shall be operational in the event of power failure.
3. Specified under Division 16 a telephone line shall be supplied to the lift.
O. Call Station Controls:
1. Constant pressure up/down control switch installed on the platform.
2. Constant pressure, elevator-style, hall call control stations provided at each landing.
3. Keyless operation.
4. Keyed operation.
5. Call Station Mounting:
a. Lower:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
b. Upper:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
P. Safety Features/Devices:
1. Grounded electrical system with upper, lower, and final limit switches.
2. Safety Pan (Required).
3. Obstruction Panel, preventing unit from moving downward when an obstruction is
encountered.
4. A grab rail shall be provided on the platform.
5. A gate with a min. height of 42” and a combination mechanical lock with an electric
contact shall be provided at the upper landing, lock must be engaged for lift to move from
landing.
6. At all landings an electromechanical interlock shall be used to keep doors closed when
lift is on another floor.
7. Electrical disconnect which will shut off power to the lift.
8. Pit stop switch mounted on Drive Tower.
Q. Finishes:
1. Finish shall be powder coating, oven baked.
2. Color:
a. Ivory.
b. White.
c. Black.
d. Grey.
e. A selection from 213 RAL colors.
2.03 SHAFTWAY VERTICAL WHEELCHAIR LIFT:
A. General Description: The Shaftway vertical platform lift (wheelchair lift) is installed in a
shaftway or hoistway built by others. The lift platform and drive tower are located within the
shaftway, while each landing consists of a door or gate, integral to the operation of the lift. At
the uppermost landing, the shaftway can extend all the way to the ceiling or to a minimum of
42” beyond the upper landing, for a more “open” application.
B. Capacity:
1. 750 lbs.
C. Lifting Height
1. Up to 42 inches.
2. Up to 60 inches.
3. Up to 72 inches.
4. Up to 96 inches.
5. Up to 120 inches.
6. Up to 144 inches.
7. Up to 168 inches.
D. Platform Size:
1. 36” W x 48” D
2. 36” W x 54” D
3. 36” W x 60” D
4. 38” W x 54” D
5. 42” W x 60” D
E. Platform Configuration:
1. Straight Through.
2. Enter/Exit same side.
3. 90 Degree.
F. Gate/Door:
1. Gate Height: 42 inches.
2. Upper Landing Gate: Detached, freestanding type.
G. Landing Openings:
1. Lower Landing: Door.
2. Intermediate Landing: Door.
3. Upper Landing: Door.
4. Upper Landing: Gate.
H. Door Construction:
1. A CSD-Rated (R) Fire Rated (B Label) flush mounted steel door and frame shall be
provided. Door shall include wire mesh vision panel with delay action door closure, dead latch,
dummy trim door handle and electric strike.
2. A CSD – Non-Rated (NR) Low profile flush mounted steel door and frame shall be
provided. Door shall include mesh vision panel with delay action door closure, dead latch,
dummy trim door handle, lock plate cover and electric strike.
a. Panels of 16 gauge galvanized steel.
b. Panels of clear Plexiglas.
c. Panels of bronze Plexiglas.
d. Panels of ¼ inch laminated safety glass.
3. A CWS – Flush mounted, solid core oak laminated door and (oak) frame shall be proved.
Door shall include mesh vision panel with delay action door closure, dead latch, dummy trim
door handle, lock plate cover and electric strike.
4. Flush mounted, 42 inches high, solid core oak laminated gate and (oak) frame shall be
provided at the upper landing. Gate includes spring hinges, dead latch, dummy trim gate
handle, lock plate cover and electric strike.
I. Upper Landing Gate Construction:
1. A minimum 42 inch high gate with combination mechanical lock and electrical contact,
pre-hung on a steel tubular frame. Gate hinges designed to auto close. Gate framework to be
1” x 1 ½” steel with 16g solid infill steel panel. Optional mid mount gate operator can be
designed and integrated into gate design.
a. Panels of 16 gauge galvanized steel.
b. Panels of clear Plexiglas.
J. Power Door Operators:
1. Location:
a. Lower Landing: Door.
b. Intermediate Landing: Door.
c. Upper Landing: Door or Gate.
2. “Smart Operation” Power Door Operator: Allows operator to open, stop at obstruction,
close and remain in NORMAL operation mode. Operator will not stop mid cycle and leave unit
non-operational.
3. Opens automatically when platform arrives at landing, pressing the call button, or
pulling on the gate.
4. ADA compliant.
5. Low voltage, 24 VDC.
K. Screw Drive:
1. Drive Type: Acme Screw Drive.
2. Travel speed: 10 fpm.
3. Motor: 1HP, 115 volt, 1 phase.
4. Power Supply:
a. 115 VAC, 30 Amp, Single Phase.
b. 230 VAC, 15 Amp, Single Phase.
5. Battery Powered Emergency Lowering:
a. Battery powered platform lowering device.
b. Automatically activates in the event of power failure.
c. Capable of running lift up and down for a minimum of 5 trips with rated load.
6. The drive mechanism shall be a stationary nut on a rotating 1” diameter Acme screw
with a secondary safety nut.
L. Hydraulic Drive:
1. Drive Type: Chain Hydraulic.
2. Travel speed: 17 to 20 fpm.
3. Motor: 2HP, 24 VDC. AC powered primary drive.
2. Power Supply: 115 VAC, 15 Amp, Single Phase
a. Powered by continuous building mains converted to 24 VDC equipped with auxiliary
battery power system. Battery power system capable of running lift up and down for a
minimum of 5 trips with rated load.
4. Standard on board 24 VDC standby battery power to operate the lift up and down in the
event of a power failure.
5. Drive mechanism shall be a 1:2 #60 roller chains hydraulic equipped with a type “A”
instantaneous slack chain safety device.
6. Hydraulic connections shall be metal and have rated pressure that withstands the
working pressure with a 5 times safety factor.
7. Bi-directional leveling, factory supplied oil collection means as required by A18.1-
8.1.4.7, Angled pressure gage standard, roller bearing sprockets, vibration isolated hydraulic
power unit.
M. Lift Components:
1. Symmetry Elevating solutions PLC Controller with self diagnostics and digital display.
A.W.A.R.E. System (Active Wiring, Accessories, Relay & Electronics Diagnosis System) generates
on-demand diagnostic codes identifying trouble or maintenance codes.
2. The Drive Tower support shall be a combination 7 gauge C Channel, 7 gauge interface
plates and 16 gauge exterior skin.
3. Platform shall be constructed of 12-gauge minimum hot rolled steel. If unit is not
installed in a 3-inch pit, an auto-retracting ramp shall be provided that extends to meet lower
landing.
4. Platform side panels shall be 42” high, Side panel framework shall be a minimum of 1”x1
½” steel. Solid infill panels shall be a minimum of 18 gauge steel.
5. Carriage platform supports shall be a minimum of ½” steel. Solid infill panels shall be a
minimum of 18 gauge steel.
6. Elevator style (Nylon) rollers shall be used for axial carriage guidance and wear pads
shall be used for horizontal stability.
7. Loaded fasteners shall be grade eight or higher. Locking fasteners shall be used in all
critical locations.
N. Drive Tower Side Wall Panels: Provide panels to cover the front and top of the open
area to the top of the top surface drive tower. Panels shall be 16 gauge galvanized steel,
mounting hardware include.
O. Platform Base & Frame Installation:
1. Pit Mount: (recess application) Level pit floor slab recessed min. 3” by others as outlined
on site specific show drawings. This application does not require ramp and allows for smooth
transition from landing into lifting equipment.
2. Floor Mount: (non-recess application) If unit is not installed in a min. 3” pit, an auto-
retracting ramp shall be provided that extends to meet the lower landing. Optional fixed
mounted ramp is available. (verify clear landing requirements if fixed ramp selected)
a. Platform Access Ramp: 12 gauge galvanized steel plates; slip resistant surfaces.
1. Ramp: Stationary type.
2. Ramp: Automatic folding type.
3. Carriage to be equipped standard with articulating base and carriage design, which
allows the carriage to be folded to reduce the tower and carriage width to 21” for ease of
installation, without removal of the carriage.
P. Platform Controls:
1. Constant pressure up/down control switches shall be installed on the platform. All
switches meet IP66 requirements.
2. An illuminated emergency stop switch / Audible alarm switch shall be provided on the
car as a means of signaling for assistance in the event of an emergency.
3. Keyless operation.
4. Keyed operation.
5. Emergency Telephone:
a. Wiring Only.
b. Platform shall be equipped with a telephone meeting the following requirements:
1. ADA compliant.
2. Shall be operational in the event of power failure.
3. Specified under Division 16 a telephone line shall be supplied to the lift.
Q. Call Station Controls:
1. Constant pressure up/down control switch installed on the platform.
2. Constant pressure, elevator-style, hall call control stations provided at each landing.
3. Keyless operation.
4. Keyed operation.
5. Call Station Mounting:
a. Lower:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
b. Intermediate:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
c. Upper:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
R. Safety Features/Devices:
1. Safety Pan.
2. Grounded electrical system with upper, lower, and final limit switches.
3. When not installed with a runway enclosure, the platform shall be equipped with an
obstruction panel that will stop only the downward travel if an obstruction is encountered.
4. A grab rail shall be provided on the platform.
5. A gate with a min. height of 42” and a combination mechanical lock with an electric
contact shall be provided at the upper landing, lock must be engaged for lift to move from
landing.
6. At all landings an electromechanical interlock shall be used to keep doors closed when
lift is on another floor.
7. Electrical disconnect which will shut off power to the lift.
8. Pit stop switch mounted on mast wall.
S. Finishes:
1. Finish shall be electro statically applied powder coating, oven baked to cure.
2. Color:
a. Ivory.
b. White.
c. Black.
d. Grey.
e. A selection from 213 RAL colors.
2.04 ENCLOSED VERTICAL WHEELCHAIR LIFT:
A. General Description: The Enclosure vertical wheelchair lift travels up and down within
its own, self-contained enclosure. The enclosure can either have an “open” look with a 42” tall
gate and enclosure extension above the upper landing, or be fully enclosed complete with full-
height doors, roof and ventilation system for outdoor applications. In addition to the drive
tower, lift platform, and enclosure, this unit also has landing doors and/or gates that are fully
integrated into the walls themselves.
B. Capacity:
1. 750 lbs.
C. Lifting Height:
1. Up to 42 inches.
2. Up to 60 inches.
3. Up to 72 inches.
4. Up to 96 inches.
5. Up to 120 inches.
6. Up to 144 inches.
7. Up to 168 inches.
D. Platform Size:
1. 36” W x 48” D
2. 36” W x 54” D
3. 36” W x 60” D
4. 42” W x 60” D
5. 42” W x 60” D
E. Platform Configuration:
1. Straight Through.
2. Enter/Exit same side.
3. 90 Degree.
F. Gate/Door:
1. Gate Height: min. 42 inches.
2. Door Height: 80” clear.
3. Platform Gate required on 3” above enclosures.
4. Integrated upper landing gate. 42 inches or 80 inches available.
G. Landing Openings:
1. Lower Landing: Gate.
2. Intermediate Landing: Integrated Lower Landing Gate.
3. Upper Landing: Door.
4. Upper Landing: Gate.
H. Door Construction:
1. A CSD-Rated (R) Fire Rated (B Label) flush mounted steel door and frame shall be
provided. Door shall include wire mesh vision panel with delay action door closure, dead latch,
dummy trim door handle and electric strike.
2. A CSD – Non-Rated (NR) Low profile flush mounted steel door and frame shall be
provided. Door shall include mesh vision panel with delay action door closure, dead latch,
dummy trim door handle, lock plate cover and electric strike.
a. Panels of 16 gauge galvanized steel.
b. Panels of clear Plexiglas.
c. Panels of bronze Plexiglas.
d. Panels of ¼ inch laminated safety glass.
3. A CWS – Flush mounted, solid core oak laminated door and (oak) frame shall be proved.
Door shall include mesh vision panel with delay action door closure, dead latch, dummy trim
door handle, lock plate cover and electric strike.
4. Flush mounted, 42 inches high, solid core oak laminated gate and (oak) frame shall be
provided at the upper landing. Gate includes spring hinges, dead latch, dummy trim gate
handle, lock plate cover and electric strike.
5. A RDI Interlock with steel housing and cam, integrated into door frame that contains
electric contacts in insure the door is both closed and locked shall be provided. (This option is
required when flush mounted door frames are provided by others).
I. Power Gate Operators:
1. Location:
a. Lower Landing Door.
b. Intermediate Landing Door.
c. Upper landing Door.
d. Upper Landing Gate.
2. “Smart Operation” Power Gate Operator: Allows operator to open, stop at obstruction,
close and remain in NORMAL operation mode. Operator will not stop mid cycle and leave unit
non-operational.
3. Opens automatically when platform arrives at landing, pressing the call button, or
pulling on the gate.
4. ADA compliant.
5. Low voltage, 24 VDC with all wiring concealed.
J. Screw Drive:
1. Drive Type: Acme Screw Drive.
2. Travel speed: 10 fpm.
3. Motor: 1HP, 115 volt, 1 phase.
4. Power Supply:
a. 115 VAC, 30 Amp, Single Phase.
b. 230 VAC, 15 Amp, Single Phase.
5. Battery Powered Emergency Lowering:
a. Battery powered platform lowering device which automatically activates in the event of
power failure. Allows platform to be raised and lowered 5 times in event of power loss.
b. Capable of running lift up and down for a minimum of 5 trips with rated load.
6. The drive mechanism shall be a stationary nut on a rotating 1” diameter Acme screw
with a secondary safety nut.
K. Hydraulic Drive:
1. Drive Type: Chain Hydraulic.
2. Travel speed: 17 to 20 fpm.
3. Motor: 2HP, 24 VDC. AC powered primary drive.
4. Power Supply: 115 VAC, 15 Amp, Single Phase.
a. Powered by continuous building mains converted to 24 VDC equipped with auxiliary
battery power system. Battery power system capable of running lift up and down for a
minimum of 5 trips with rated load.
5. Standard on board 24 VDC standby battery power to operate the lift up and down in the
event of a power failure.
6. Drive mechanism shall be a 1:2 #60 roller chains hydraulic equipped with a type “A”
instantaneous slack chain safety device.
7. Hydraulic connections shall be metal and have rated pressure that withstands the
working pressure with a 5 times safety factor.
8. Bi-directional leveling, factory supplied oil collection means as required by A18.1-
8.1.4.7, Angled pressure gage standard, roller bearing sprockets, vibration isolated hydraulic
power unit.
L. Enclosure Panels:
1. 16 gauge galvanized steel.
2. Clear Plexiglas.
3. Bronze Plexiglas.
4. Laminated Safety Glass.
M. Lift Components:
1. Symmetry Elevating solutions PLC Controller with self diagnostics and digital display.
A.W.A.R.E. System (Active Wiring, Accessories, Relay & Electronics Diagnosis System) generates
on-demand diagnostic codes identifying trouble or maintenance codes.
2. The Drive Tower support shall be a combination 7 gauge C Channel, 7 gauge interface
plates and 16 gauge exterior skin.
3. Platform shall be constructed of 12-gauge minimum hot rolled steel. If unit is not
installed in a 3-inch pit, an auto-retracting ramp shall be provided that extends to meet lower
landing.
4. Platform side panels shall be 42” high, Side panel framework shall be a minimum of 1”x1
½” steel. Solid infill panels shall be a minimum of 18 gauge steel.
5. Carriage platform supports shall be a minimum of ½” steel. Solid infill panels shall be a
minimum of 18 gauge steel.
6. Elevator style (Nylon) rollers shall be used for axial carriage guidance and wear pads
shall be used for horizontal stability.
7. Loaded fasteners shall be grade eight or higher. Locking fasteners shall be used in all
critical locations.
N. Enclosure Height Above Upper Landing:
1. Enclosure shall extend 42 inches above the upper landing level.
2. Enclosure shall extend 80 inches above the upper landing level.
3. 3 inches above with platform gate.
O. Drive Mast Side Wall Panels: Provide 16 gauge galvanized panels and mounting
hardware to cover the void between side of enclosure, drive mast and adjacent wall at the
following locations:
1. Lower Landing.
2. Intermediate Landing.
3. Upper Landing.
P. Platform Base & Frame Installation:
1. Pit Mount: (recess application) Level pit floor slab recessed min. 3” by others as outlined
on site specific show drawings. This application does not require ramp and allows for smooth
transition from landing into lifting equipment.
2. Floor Mount: (non-recess application) If unit is not installed in a min. 3” pit, an auto-
retracting ramp shall be provided that extends to meet the lower landing. Optional fixed
mounted ramp is available. (verify clear landing requirements if fixed ramp selected)
a. Platform Access Ramp: 12 gauge galvanized steel plates; slip resistant surfaces.
1. Ramp: Stationary type.
2. Ramp: Automatic folding type.
3. Carriage to be equipped standard with articulating base and carriage design, which
allows the carriage to be folded to reduce the tower and carriage width to 21” for ease of
installation, without removal of the carriage.
Q. Optional Features:
1. Enclosure Protection: Single sided or double sided roof. Angle and direction options
available.
2. Ventilation System: Single exhaust fan, thermostatically controlled with a 12 VDC
battery backup. Required continuous main power for Hydraulic Drive.
3. Outdoor Protection Package: Lift shall include modifications recommended by
manufacturer for performance in extreme outdoor weather conditions.
R. Platform Controls:
1. Constant pressure up/down control switches shall be installed on the platform. All
switches meet IP66 requirements.
2. An illuminated emergency stop switch / Audible alarm switch shall be provided on the
car as a means of signaling for assistance in the event of an emergency.
3. Keyless operation.
4. Keyed operation.
5. Emergency Telephone:
a. Wiring Only.
b. Platform shall be equipped with a telephone meeting the following requirements:
1. ADA compliant.
2. Shall be operational in the event of power failure.
3. Specified under Division 16 a telephone line shall be supplied to the lift.
S. Call Station Controls:
1. Constant pressure up/down control switch installed on the platform.
2. Constant pressure, elevator-style, hall call control stations provided at each landing.
3. Keyless operation.
4. Keyed operation.
5. Call Station Mounting:
f. Lower:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
g. Intermediate:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
h. Upper:
1. In-Frame.
2. Surface Mount.
3. Flush Mount.
T. Safety Features/Devices:
1. Grounded electrical system with upper, lower, and final limit switches.
2. A grab rail shall be provided on the platform.
3. A gate with a min. height of 42” and a combination mechanical lock with an electric
contact shall be provided at the upper landing, lock must be engaged for lift to move from
landing.
4. At all landings an electromechanical interlock shall be used to keep doors closed when
lift is on another floor.
5. Electrical disconnect which will shut off power to the lift.
6. Pit stop switch mounted on mast wall.
U. Finishes:
1. Finish shall be electro statically applied powder coating, oven baked to cure.
2. Color:
a. Ivory.
b. White.
c. Black.
d. Grey.
e. A selection from 213 RAL colors.
2.05 HYBRID VERTICAL WHEELCHAIR LIFT:
B. General Description: The Hybrid looks and feels like an elevator, but operates like a lift.
Available in many different sizes and configurations, features include a full height cab, non-load
bearing ceiling and a wide variety of optional features and finishes. Customize the doors and
cab to match the style and décor of your commercial facility or home.
C. Capacity:
1. 750 lbs.
D. Lifting Height:
1. Up to 120 inches.
2. Up to 180 inches.
3. Up to 240 inches.
E. Platform Size:
1. 36” W x 48” D
2. 36” W x 54” D
3. 36” W x 60” D
4. 42” W x 60” D
5. 42” W x 60” D
F. Platform Configuration:
1. Straight Through.
2. Enter/Exit same side.
3. 90 Degree.
G. Landing Openings:
1. All Landings: Doors interlocked with lift controls.
H. Door Construction:
1. A CSD-Rated (R) Fire Rated (B Label) flush mounted steel door and frame shall be
provided. Door shall include wire mesh vision panel with delay action door closure, dead latch,
dummy trim door handle and electric strike.
2. A CSD – Non-Rated (NR) Low profile flush mounted steel door and frame shall be
provided. Door shall include mesh vision panel with delay action door closure, dead latch,
dummy trim door handle, lock plate cover and electric strike.
a. Panels of 16 gauge galvanized steel.
b. Panels of clear Plexiglas.
c. Panels of bronze Plexiglas.
d. Panels of ¼ inch laminated safety glass.
3. A CWS – Flush mounted, solid core oak laminated door and (oak) frame shall be proved.
Door shall include mesh vision panel with delay action door closure, dead latch, dummy trim
door handle, lock plate cover and electric strike.
4. A 24V DC, fail secure electric strike that contains electric contacts to insure the door is
both closed and locked shall be provided. (This option is required when flush mounted door
frames are provided by others.)
I. Provide Power Door/Gate Operator:
1. ADA Compliant and obstruction sensitive.
2. Door opens and closes at landing.
3. Location:
a. Lower Landing: Door & Car Gate.
b. Intermediate Landing (s): Door & Car Gate.
c. Upper Landing: Door & Car Gate.
J. Hydraulic Drive:
1. Drive Type: Roped Hydraulic.
2. Travel speed: 30 fpm.
3. Motor: 3HP, 208/230 VAC. Submersed Power Unit.
4. Power Supply: 208/230 VAC, 30 Amp, Single Phase
5. Standard on board 24 VDC standby battery power to operate the lift up and down in the
event of a power failure.
6. Drive mechanism shall be a 1:2 roped hydraulic with type “A” instantaneous slack rope
safety device.
7. Hydraulic connections shall be metal and have rated pressure that withstands the
working pressure with a 5 times safety factor.
8. Bi-directional leveling, factory supplied oil collection means as required by A18.1-
8.1.4.7, vibration isolated hydraulic power unit.
K. Lift Components:
1. Heavy duty car sling with roller guide wheels running on 6-1/4 lb. per foot steel T-rails,
quiet submersed pump and motor (3 HP), factory pre-set and tested 2-speed valve for smooth
start and stop. Pump unit to be located in a machine room outside of the hoistway.
2. Symmetry Elevating solutions PLC Controller with self diagnostics and digital display.
S.M.A.R.T. System (Self-Monitoring Alert Response Technology) generates on-demand
diagnostic codes identifying trouble or maintenance codes, and broadcasts these codes to the
controller, Hall Stations, and to the Car.
3. Loaded fasteners shall be grade eight or higher. Locking fasteners shall be used in all
critical locations.
L. Lower Landing Pit:
1. 6 inches minimum.
2. 8 inches preferred.
M. Car Controls:
1. Fully automatic illuminated push button.
a. Braille Illuminated Buttons.
2. An illuminated emergency stop switch / Audible alarm switch shall be provided on the
car as a means of signaling for assistance in the event of an emergency.
3. Keyless operation.
4. Keyed operation.
5. Digital Floor Display.
6. Emergency Telephone:
a. Wiring Only.
b. Platform shall be equipped with a telephone meeting the following requirements:
1. ADA compliant.
2. Shall be operational in the event of power failure.
3. Specified under Division 16 a telephone line shall be supplied to the lift.
N. Call Station Controls:
1. Fully automatic illuminated push button.
a. Braille Illuminated Buttons.
2. Hall Station Type:
a. Keyless Operation.
b. Keyed Operation.
3. Finish:
a. Brushed Stainless.
b. Polished Stainless.
c. Brushed Brass.
d. Polished Brass.
e. Oil Rubbed Brass.
f. Vintage Bronze.
g. Black.
h. Cooper – Silver.
i. Brushed Silver.
j. Natural Metal.
k. Brushed Bronze.
l. Japanese Brown.
m. Antique Brown.
4. Call Station Mounting:
a. Lower Floor:
1. Wall mounted recessed.
2. Mounted within the door frame.
b. Second Floor:
1. Wall mounted recessed.
2. Mounted within the door frame.
c. Third Floor:
1. Wall mounted recessed.
2. Mounted within the door frame.
d. Upper Floor:
1. Wall mounted recessed.
2. Mounted within the door frame.
O. Safety Features/Devices:
1. Motor Controller supply disconnect (located in controller).
2. Safety switch for car gate(s).
3. Electromechanical hoistway door interlocks.
4. Recessed Phone box.
5. Rupture Valve (Type “C” Safety)
6. Emergency alarm button in car, Emergency keyed stop switch in car.
7. Battery backup emergency car lights and alarm.
8. Upper and lower final limit switches.
9. Low oil protection timer circuit.
10. Grounded electrical system with upper, lower, and final limit switches.
11. Electrical disconnect which will shut off power to the lift.
12. Pit stop switch mounted on mast wall.
P. Cab Design:
1. Interior Walls: Panel selections.
a. Flat Panel.
b. Shaker Panel.
c. Inset Panel.
d. Raised Panel.
2. Interior Walls: Wood Species.
a. Alder.
b. Birch.
c. Cherry.
d. Hickory.
e. Mahogany.
f. Maple.
g. Red Oak.
h. Walnut.
i. White Oak.
3. Interior Walls: Stain.
a. No Stain – Unfinished.
b. Country Pine.
c. Golden Oak.
d. Satin Clear Coat.
e. Traditional Cherry.
f. Custom as selected by Architect.
4. Ceiling: Panel selections.
a. Flat Panel.
b. Shaker Panel.
c. Inset Panel.
d. Raised Panel.
5. Ceiling: Wood Species.
a. Alder.
b. Birch.
c. Cherry.
d. Hickory.
e. Mahogany.
f. Maple.
g. Red Oak.
h. Walnut.
i. White Oak.
6. Ceiling: Stain.
a. No Stain – Unfinished.
b. Country Pine.
c. Golden Oak.
d. Satin Clear Coat.
e. Traditional Cherry.
f. Custom as selected by Architect.
7. Car Operating Panel Finish:
a. Brushed Stainless.
b. Polished Stainless.
c. Brushed Brass.
d. Polished Brass.
e. Oil Rubbed Brass.
f. Vintage Bronze.
g. Black.
8. Handrail Finish:
a. Matching Wood.
b. Brushed Stainless.
c. Polished Stainless.
d. Brushed Brass.
e. Polished Brass.
f. Vintage Bronze.
g. Oil Rubbed Brass.
9. Floor: Unfinished ¾ inch plywood construction.
10. Lighting:
a. 115 VAC, single phase, 15 Amps.
b. Failure of one lamp shall not cause the remaining lamps to extinguish.
c. Lights shall illuminate automatically when the elevator door is opened and remain on
the entire duration of use. Lights shall automatically turn off after a preset time the elevator is
not in use.
d. Recessed LED Lights with Trim.
1. (2) Two.
2. (4) Four.
e. Finish:
1. Black Trim.
2. Brushed Stainless.
3. Bronze.
4. Polished Brass.
PART 3 EXECUTION
3.01 ACCEPTABLE INSTALLERS:
A. Subcontractor Qualifications: A company that is listed as an authorized Symmetry
Elevating Solutions dealer. See www.symmetryelevator.com for details.
B. Electrical devices, service and final connections shall be by a qualified electrician.
3.02 EXAMINATION:
A. Preliminary work must be properly prepared, including hoistway construction (if
needed), landings and machine space, before installation.
B. Verify hoistway shaft (if needed) and machine space are the correct size and within
acceptance.
C. Verify required landings and openings are the correct size and within acceptance.
D. When required verify machine room is provided with lighting, light switch, outlets and
meets the clear space requirements of ASME A17.1.
E. Verify electrical power is available and of within acceptance.
F. Notify Architect of any inadequate preparation when preliminary work is the
responsibility of another installer.
3.03 PREPARATION:
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces and unit using the methods recommended by the manufacturer for
achieving the optimum performance of vertical wheelchair lift.
3.04 INSTALLATION:
A. Unit shall be installed and operated in accordance with the ICC/A117.1, NEC and ASME
A18.1 Guidelines.
B. A dedicated electrical supply provided to the disconnect shall be capable of supplying
sufficient power.
C. GC to coordinate “work by others” with lift contractor.
D. The installation of the vertical wheelchair lift shall be made in accordance with approved
plans and specifications and the manufacturer’s installation instructions.
E. Startup and test unit in accordance with manufacturer’s instructions.
F. Adjust for smooth operation.
3.05 FIELD QUALITY CONTROL:
A. Perform tests in compliance with ASME 17.1 or A18.1 and as required by authorities
having jurisdiction.
B. Load the vertical lift to rated capacity and test for several cycles to insure proper
operation. No mechanical failures shall occur and no wear that would affect the reliability of
the unit shall be detected.
C. Schedule necessary tests with Architect, Owner, Contractor, and any authorities having
jurisdiction.
3.06 PROTECTION:
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
C. Clean unit prior to final inspection
REFERENCE: Home Elevator - Hydraulic Drive – Symmetry Elevating Solutions - Sweets
(construction.com)
Vertical Platform Lift - Enclosed Lift Plexi-glass – Symmetry Elevating Solutions - Sweets
(construction.com)

You might also like