Protection and Distribution 1A To 6300A: Our Price List. Effective From 1st August 2009
Protection and Distribution 1A To 6300A: Our Price List. Effective From 1st August 2009
Protection and Distribution 1A To 6300A: Our Price List. Effective From 1st August 2009
Ordering is Easy We have made ordering easy for you by including order codes. If you need help with ordering or selection, please call the telephone number shown below. Technical Support is Free Our helpful Applications Team are at your disposal. They provide free, detailed advice on the application of our products and use industry-leading electrical design software packages.
1A TO 6300A: CONTENTS
New Products Preview
NEW PRODUCTS
11-24
TemBreak TemPower
Moulded Case Circuit Breaker and Circuit Breaker with Residual Current Protection
27-103
105-117
127-130
TemMeasure
133-136
138
page 3
TEMMEASURE
TEMPROTECT
TemProtect
PFC
119-125
TEMPOWER 2
TEMBREAK 2
TEMWAY
TemWay
Terasaki are now setting the highest standards for customer service, competitiveness and product quality. This price list includes our largest-ever portfolio of electrical safety and protection products: from 1A to 6300A. Our latest exciting product developments are highlighted on the following pages...
page 4
TemWay 250 LP Our solution incorporates two separately metered busbar systems for lighting and power circuits, with a range of different configurations of outgoing ways. Details on page 15-16.
page 5
NEW PRODUCTS
PRICE LIST PRICE GROUP A
NEW PRODUCTS
Tembreak 2 Motorised mechanically and electrically interlocked MCCBs fully assembled on a mounting bracket ready for installation. A wiring controller and wiring harnesses suitable for use with the TemTransfer Automatic Changeover Controller are also available. Details on pages 46/61/80.
page 6
NEUTRAL LINKS
NEW PRODUCTS
MCCB Neutral Link When combined with a three-pole MCCB, the neutral link provides a termination for the neutral conductor at the same pole-pitch and terminal height as the neutral pole of a four-pole MCCB. Shrouds are available separately. Details on page 45/60/79/89/99
page 7
NEW PRODUCTS
Tembreak2 Integrated VTs and CTs monitor current, voltage, instantaneous power, energy, power factor and harmonic currents. Data can be transmitted externally using the modbus protocol. LCD can be supplied mounted vertically or horizontally. Details on page 64/65/72
page 8
page 9
page 10
page 11
Scratch-resistant, high-gloss galvanised steel Multiple easy-clear knockouts Lockable transparent cover IP40
Incoming Device 63A, 30mA, 2P RCCB 80A, 30mA, 2P RCCB 100A, 30mA, 2P RCCB 63A, 100mA, 2P RCCB 63A, 300mA, 2P RCCB 80A, 300mA, 2P RCCB 100A, 300mA, 2P RCCB
page 12
page 13
Manufactured in accordance with BS5486 Part 13 Sheet steel enclosure, door and cover plates Lockable doors with 180o concealed hinges Door can be left or right handed Fault Rating 30kA conditional
Busbar rating 250 Amps (Joint free) Earth and shrouded neutral terminals IP31 protection is standard Colour coding for all connections as standard Generous cabling space Powder coating (RAL 7035w)
Dimensions (mm)
Outgoing Ways 6 8 12 16 20 24
Incoming Device 125A TP Switch Disconnector 160A TP Switch Disconnector 250A TP Switch Disconnector 160A TP MCCB Incomer 36kA 250A TP MCCB Incomer 36kA
Dimensions (mm) Extension Boxes Multiservice Extension box Extension box for metering * Extension box for cabling
* Box includes 250A CTs and DIN96 Cutout
Description Blanking plates for outgoing ways pack of 6 MCB Padlock Device MCCB Padlock Device 125/250A
page 14
Energy used for lighting and power can be metered separately. Features:
Sheet steel enclosure, door and cover plates Lockable doors with 180 o concealed hinges Earth and shrouded neutral terminals Door sealing gasket Door can be left or right handed Powder coated (RAL 7035w)
Outgoing Ways 6+6 6+8 6+10 8+8 8+10 8+12 10+10 10+12 12+12 16+16 20+20
Code LP26TP6TP LP26TP8TP LP26TP10TP LP28TP8TP LP28TP10TP LP28TP12TP LP28TP10TP LP210TP12TP LP212TP12TP LP216TP16TP LP220TP20TP
TEMWAY
80A 4P (6 DIN module) type C 100A 4P (6 DIN module) type C 125A 4P (6 DIN module) type C
Dimensions (mm) Incomer Box Suitable for 250A frame MCCB or switch disconnector Code 404202301 Width 420 Height 250 Depth 165
Incoming Device and Switch Disconnectors* 125A TP Switch Disconnector 160A TP Switch Disconnector 250A TP Switch Disconnector 160A TP MCCB Incomer 36kA 250A TP MCCB Incomer 36kA
* Incomer box required
Price
page 16
TemDin 2 Miniature Circuit Breakers protect installations against overloads and short-circuits. Features:
10kA BS EN 60898 15kA BS EN 60947-2 Terminal capacity of 35mm 2 DIN rail mounting
CURVE B poles 1 In (A) 0.3 0.5 0.75 1 1.6 2 2.5 3 3.5 4 6 10 16 20 25 32 40 50 63 Code DH06B10006 DH06B10010 DH06B10016 DH06B10020 DH06B10025 DH06B10032 DH06B10040 DH06B10050 DH06B10063 Price C Code DH06C10006 DH06C10010 DH06C10016 DH06C10020 DH06C10025 DH06C10032 DH06C10040 DH06C10050 DH06C10063 Price D Code DH06D100V3 DH06D100V5 DH06D100V7 DH06D10001 DH06D101V6 DH06D10002 DH06D102V5 DH06D10003 DH06D103V5 DH06D10004 DH06D10006 DH06D10010 DH06D10016 DH06D10020 DH06D10025 DH06D10032 DH06D10040 DH06D10050 DH06D10063
page 17
CURVE poles 3 In (A) 0.3 0.5 0.75 1 1.6 2 2.5 3 3.5 4 6 10 16 20 25 32 40 50 63 B Code DH06B30006 DH06B30010 DH06B30016 DH06B30020 DH06B30025 DH06B30032 DH06B30040 DH06B30050 DH06B30063 C Code DH06C30006 DH06C30010 DH06C30016 DH06C30020 DH06C30025 DH06C30032 DH06C30040 DH06C30050 DH06C30063 D Code DH06D300V3 DH06D300V5 DH06D300V7 DH06D30001 DH06D301V6 DH06D30002 DH06D302V5 DH06D30003 DH06D303V5 DH06D30004 DH06D30006 DH06D30010 DH06D30016 DH06D30020 DH06D30025 DH06D30032 DH06D30040 DH06D30050 DH06D30063
page 18
Specification
Short circuit capacity Tripping characteristic Type Sensitivity Rated voltage Frequency Calibration temperature Terminal capacity Standards
Nominal current ratings from 6 to 32A Residual current circuit breakers with overcurrent protection designed for total safety. - Residual current circuit breakers protect people against electrocution from direct or indirect contact (30mA). They also protect property from res caused by the breakdown of insulation of conductors. - ZDH RCBOs also protect circuits against overloads and short circuits.
CURVE B In(A) 6 10 16 20 32 Sensitivity (mA) 30 30 30 30 30 Type A A A A A Code ZDH041P/06B/003-A ZDH041P/10B/003-A ZDH041P/16B/003-A ZDH041P/20B/003-A ZDH041P/32B/003-A Price Code ZDH041P/06C/003-A ZDH041P/10C/003-A ZDH041P/16C/003-A ZDH041P/20C/003-A ZDH041P/32C/003-A C Price
page 19
Manufactured in accordance with BS5486 Part 13 Sheet steel enclosure, door and cover plates Lockable doors with 180 o concealed hinges Door can be left or right handed Powder coding (RAL 7035w) Generous cabling space Fault rating 50kA for 1 second 400A Panel Board
Colour coding for all connections as standard Totally encapsulated, full insulated 400A or 800A 415Vac, busbar system One piece copper construction Maintenance free Earth and neutral terminals IP31 protection as standard Incoming kits include all shrouds and links
Dimensions (mm)
Outgoing Ways 6 12
Price
6, 12
405402001
Incoming Device 250A TP Switch Disconnector 400A TP Switch Disconnector 250A TP MCCB Incomer 400A TP MCCB Incomer Padlock Device
Price
Price
6, 12
405402001
Incoming Device 630A TP Switch Disconnector 800A TP Switch Disconnector 630A TP MCCB Incomer 800A TP MCCB Incomer Padlock Device
page 20
Dimensions (mm) Extension Boxes TemWay 400/800 Extension Box TemWay 400 Meter Box* TemWay 800 Meter Box*
* Box includes CTs and DIN96 Cutout
Code
Price
404802300
Side-mounted Cable Boxes 6-way TemWay 400/800 12-way TemWay 400/800 18-way TemWay 800
Price
* Prices are for one cable box which can be mounted either on the right or on the left of the panelboard
Side-mounted Metering Boxes 6-way TemWay 400/800 with 3 DIN96 cutouts 12-way TemWay 400/800 with 6 DIN96 cutouts 18-way TemWay 800 with 9 DIN96 cutouts
Code
Price
404802304
404802305
404802306
* Prices are for one cable box which can be mounted either on the right or on the left of the panelboard. Blanking plates for unused cutouts are included. Mounting brackets for CTs are included.
page 21
poles 1
S125-NF Code 254796 254703 254710 254727 254734 254741 254758 254765 254772 254789
25kA Price
25kA Price
36kA Price
65kA* Price
page 22
S160-NF Code 326707 326714 326721 326738 326745 326752 326769 326776 326790 326790 326806
25kA Price
36kA Price
36kA Price
page 23
PAN ASSEMBLIES
Specication:
Fully insulated 250A 415Vac busbar system Busbar short circuit withstand is certied 30kA conditional One piece copper construction Maintenance free Colour coding for all connections as standard
TEMWAY
Pan Assembly inc Tray Earth & Neutral Outgoing Ways 6 8 12 16 20 24 Code 404203006 404203008 404203012 404203016 404203020 404203024 Price
Specication:
Totally encapsulated, fully insulated 400A 415Vac busbar system
Short circuit withstand is ASTA certied 50kA for 1 second One piece copper construction Maintenance free Colour coding for all connections as standard Shroud for spare/unused outgoing terminals
Pan Assembly Outgoing Ways 6 12 Code 404403106 404403112 Price 262.04 404.71
Pan Assembly inc Tray Earth & Neutral Code Price 404403006 404403012
Specication:
Totally encapsulated, fully insulated 800A 415Vac busbar system Short circuit withstand is ASTA certied 50kA for 1 second One piece copper construction Maintenance free Colour coding for all connections as standard
Pan Assembly Outgoing Ways 6 12 Code 404803106 404803112 Price 326.41 527.62
Pan Assembly inc Tray Earth & Neutral Code Price 404803006 404803012
page 24
page 25
page 26
A note on item codes: 13-digit EAN codes are shown in full against applicable items. These correspond to the barcode on the product packaging and facilitate inventory management using barcode scanning. Only the last 6 digits of the code are required to identify an item from the TemBreak 2 range of products The preceding 7 digits may be omitted from orders and enquiries.
page 27
page 28
Rating, /n MCCB <=63A 100A 125A 160A 200A 250A 400A Rating, /n MCCB <=63A 100A 125A 160A 200A 250A 400A 630A
25kA Fault Level E125NJ E125NJ E125NJ E250NJ E250NJ E250NJ E400NJ NSX100F NSX100F NSX160F NSX160F NSX250F NSX250F NSX400F T1C T1C T1C T1C T3N T3N T5N
MCCB
Auxiliary Switch
Shunt
UVT
36kA Fault Level S125NJ S125NJ S125NJ S160NJ S250NJ S250NJ S400CJ E630NE NSX100F NSX100F NSX160F NSX160F NSX250F NSX250F NSX400F NSX630F T1N T1N T1N T1N T3N T3N T5N T5N
MCCB
Auxiliary Switch
Shunt
UVT
Rating, /n 50kA Fault Level MCCB <=63A S125GJ NSX100N 100A S125GJ NSX100N 125A S125GJ NSX160N 160A S160GJ NSX160N 200A S250GJ NSX250N 250A S250GJ NSX250N 400A S400NJ NSX400N 630A S630CE NSX630N 800A XS800NJ NS800N 1000A XS1000CE NS1000N 1250A XS1250CE NS1250N
MCCB T2S T2S T2S T2S T3S T3S T5S T5S T6S T6S T7S
Auxiliary Switch
Shunt
UVT
Rating, /n 65kA Fault Level MCCB <=63A S125GJ NSX100H 100A S125GJ NSX100H 125A S125GJ NSX160H 160A S160GJ NSX160H 200A S250GJ NSX250H 250A S250GJ NSX250H 400A S400GJ NSX400H 630A S630GE NSX630H 800A XH800SE NS800H 1000A XS1250SE NS1000H 1250A XS1250SE NS1250H
MCCB T2H T2H T2H T2H T3H T3H T5H T5H T6H T6H T7H
Auxiliary Switch
Shunt
UVT
Rating, /n MCCB <=63A 100A 125A 160A 200A 250A 630A 800A 1000A 1250A
80kA Fault Level H125NJ H125NJ H125NJ H160NJ H250NJ H250NJ XH800PJ XH800PJ XS1250SE XS1250SE NSX100S NSX100S NSX160S NSX160S NSX250S NSX250S NSX630S NS800L NS1000L NS1600b T2L T2L T2L T2L T4L T4L T5L T6L T6L T7L
MCCB
Auxiliary Switch
Shunt
UVT
Notes: 1: Above prices for 3 Pole MCCBS 2: Breaking Capacities based on 400V AC 3: Alarm Switches same price as auxiliary Switches upto 630A
page 29
TEMBREAK 2
Safety Lock
5. MODULAR SIZES
All current ratings up to 630A can be supplied in 2 sizes: the 250A and 630A sizes. The compact 125A size offers the same features and performance but with reduced dimensions and cost.
page 30
7. DIRECT OPENING
Under the heading Measures to minimise the risk in the event of failure, IEC 60204-1 Safety of Machinery-Electrical Equipment Machinery includes the following recommendation: -the use of switching devices having positive (or direct) opening operation.
8. UNSURPASSED FLEXIBILITY
Overload protection is adjustable between 63% and 100% of the rating. Short-circuit protection is adjustable on all thermal magnetic models. Short-circuit protection settings are suitable for motor starting on all models, including the compact 125A frame.
ON (I)
OFF (O)
TRIPPED
TEMBREAK 2
S160 S160
1. IR is the thermal element adjustment dial and is used to set the rated current to match the conductor rating. IR can be set between 0.63 and 1.0 times In. 2. Ii is the magnetic element adjustment dial and is used to set the short circuit tripping threshold to suit the application.
H160 L160 E250 S250 S250 H250 L250 E400 S400 S400 S400 H400 L400
Ii can be set between 6 and 12 times In on models with In <=100A and models with In = 400. Ii can be set between 6 and 10 times In on models with In 125A and 250A.
Ii can be set between 6 and 13 times In on models with In= 160A and In = 200A.
ELECTRONIC PROTECTION
TemBreak 2 MCCBs from 250A frame to 630A frame are available with electronic protection units. Current ratings, In, of 40A, 125A, 250A, 400A and 630A are available. Overload protection can be adjusted to 0.4 x In. These offer great flexibility as their characteristics can be set to suit a wide range of application conditions. Terasaki offer one of the most adaptable protection units on the market: If you require a characteristic which is not available as a preset on our standard electronic protection unit, send us the details and we will program a customised characteristic to your specification.*
Selecting a Preset Characteristic for a 400A TemBreak 2 MCCB with Electronic Protection
Every TemBreak 2 electronic protection unit includes overload protection (L), delayed short-circuit protection (S) and instantaneous protection (I) as standard. page 32
1. I n is the adjustable tripping threshold for residual current (earth leakage) protection. It can be set between 30mA and 3A. Available settings are shown below: 2. t (ms) is a time delay which is introduced to the residual current (earth leakage) protection characteristic. Available settings are shown below. It can also be set to 0 (max. actual tripping time is 40ms) or NT (No Trip - tripping time = ). The maximum breaking time at each setting is shown in brackets. Note that if I n is set at 30mA, t defaults to 0. 3. Please refer to page XX for Thermal Element Adjustment (IR)
8
(A)
(ms)
Ii
12 x In (+/- 20%) 10 x In (+/- 20%) 13 x In (+/- 20%) 10 x In (+/- 20%)
0.03, 0.1, 0.3, 0.5, 1, 3 0.03, 0.1, 0.3, 0.5, 1, 3 0.03, 0.1, 0.3, 0.5, 1, 3 0.03, 0.1, 0.3, 0.5, 1, 3
0 (40), 60 (195), 200 (365), 400 (620), 700 (950), NT ( ) 700 (950), NT ( ) 700 (950), NT ( ) 700 (950), NT ( )
8 8 8 8
0 (40), 60 (195), 200 (365), 400 (620), 0 (40), 60 (195), 200 (365), 400 (620), 0 (40), 60 (195), 200 (365), 400 (620),
page 33
TEMBREAK 2
1P MCCBs
Dimensions h d w (mm) (mm) (mm) 155 30 68
Model S125-NF
In (A)
16 25 20 32 40 50 63 80 100 125
1P 4547560 254703 4547560 254710 4547560 254727 4547560 254734 4547560 254741 4547560 254758 4547560 254765 4547560 254772 4547560 254789 4547560 254796
TEMBREAK 2
Icu=25 kA
Thermal Magnetic
Model S160-NF
In (A)
16 25 20 32 40 50 63 80 100 125 160
1P 4547560 326707 4547560 326714 4547560 326721 4547560 326738 4547560 326745 4547560 326752 4547560 326769 4547560 326776 4547560 326783 4547560 326790 4547560 326806
Icu=25 kA
Thermal Magnetic
A note on item codes: 13-digit EAN codes are shown in full against applicable items. These correspond to the barcode on the product packaging and facilitate inventory management using barcode scanning. Only the last 6 digits of the code are required to identify an item from the TemBreak 2 range of products. The preceding 7 digits may be omitted from orders and enquiries.
page 34
Solderless Terminals Field Fit Accessory 1 clamp for S125-NF 1 clamp for S160-NF
page 35
TEMBREAK 2
IR (A)
13-20 32-50 20-32
Price
Icu =25 kA
Thermal Magnetic
TEMBREAK 2
40-63
63-100
4547560 254826
4547560 254840
Thermal Magnetic
Icu = 36kA
32-50
20-32
63-100
40-63
4547560 255031
4547560 255021
4547560 255014
4547560 255137
4547560 255151
4547560 255144
Icu = 65kA
Thermal Magnetic
32-50
20-32
79-125
63-100
40-63
4547560 255229
4547560 255212
4547560 255304
4547560 255311
Price
ICU = 25kA
4547560 256707
Magnetic Only/
Low Instantaneous
40-63
63-100 80-125
4547560 256622
4547560 257957
547560 257940
3P Low Instantaneous
Price
4547560 258008
4P Low Instantaneous
4547560 258015
S125-NJ
ICU = 36kA
Magnetic Only/
4547560 257117 4547560 257131 4547560 257148 4547560 257155 4547560 257605 4547560 257629
4547560 258251
4547560 258312
Low Instantaneous
40-63
63-100 80-125
S125-GJ
ICU = 65kA
Magnetic Only/
4547560 258558
4547560 258619
Low Instantaneous
4547560 257650
4547560 258565
4547560 258572
4547560 258626
547560 258633
page 36
IR (A)
12.5-20 32-50 40-63 20-32
Price
4P 4547560 622205 4547560 622212 4547560 622229 4547560 622243 4547560 622250 4547560 622601
Price
Icu =25 kA
4547560 622120 4547560 622137 4547560 622144 4547560 622151 4547560 622502 4547560 622526 4547560 622533 4547560 622540 4547560 622557 4547560 622304 4547560 622328 4547560 622335 4547560 622342 4547560 622359 4547560 622519
Icu = 36kA
32-50 40-63
20-32
4547560 622618 4547560 622625 4547560 622632 4547560 622649 4547560 622656 4547560 622403 4547560 622410 4547560 622427 4547560 622431 4547560 622441 4547560 622458
Icu = 65kA
4547560 622311
63-100 80-125
CBR with Residual Monitor and Remote Trip Module Model ZE125-NJ ZP
IR (A)
12.5-20 32-50 40-63 20-32
3P 4547560 622700 4547560 622724 4547560 622731 4547560 622746 4547560 622755 4547560 623103 4547560 623127 4547560 623134 4547560 623141 4547560 623158 4547560 622908 4547560 622922 4547560 622930 4547560 622946 4547560 622953 4547560 622717
Price
4P 4547560 622816 4547560 622823 4547560 622830 4547560 622847 4547560 622854 4547560 623202 4547560 623219 4547560 623266 4547560 623233 4547560 623240 4547560 623257 4547560 623004 4547560 623011 4547560 623028 4547560 623035 4547560 623042 4547560 623059 4547560 622809
Price
Icu = 25kA
Icu = 36kA
4547560 623110
Icu = 65kA
4547560 622915
63-100 80-125
page 37
TEMBREAK 2
4547560 622236
ON
ON
OFF
OFF
TEMBREAK 2
LOAD
3 Poles in Series
LOAD
4 Poles in Series
DC Application
Model S125-ND @ 350V DC Icu = 10kA Thermal Magnetic Poles wired in series
IR (A)
32 50 100 125 63 20
3P 4547560 245817 4547560 245824 4547560 245831 4547560 245848 4547560 245855 4547560 245800
Price
4P
Price
Model S125-ND @ 500V DC Icu = 7.5kA Thermal Magnetic Poles wired in series (4 Pole Version only)
IR (A)
32 20
3P 4547560 4547560
Price
Price
50
125
100
63
4547560
4547560
4547560 4547560
Model S125-ND @ 600V DC Icu = 5kA Thermal Magnetic Poles wired in series (4 Pole Version only)
IR (A)
20 50 63 32
Price
Price
125
100
4547560
4547560
4547560
page 38
Price
page 39
TEMBREAK 2
TEMBREAK 2
Straight type
Rear
Flat Bar Studs Field Fit Accessory 3 studs 4 studs Code 4547560 080111 4547560 080128 Price
Fixed Part of
Plug-in Mount Blocks Field Fit Accessory 3P 4P A plug-in conversion is also required to complete the plug-in MCCB *Not suitable for use with CBR Code 4547560 060267 4547560 060359 Price
Plug-in Conversion
For Removable Part of Plug-in MCCB Field Fit Accessory 3P 4P A fixed part is also required to complete the plug-in MCCB Code 4547560 800160 4547560 800177 *Not suitable for use with CBR Price
page 40
Plug for Removable Part of MCCB, 3 terminals Field Fit Accessory Plug for auxiliary switches and alarm switches Plug for shunt trips and undervoltage trips Order one plug for each internal accessory
Price
page 41
TEMBREAK 2
TEMBREAK 2
External
Field Fit Accessory Black handle IP3X Black handle IP3X with keylock Red handle IP3X Red handle IP3X with keylock Black handle IP5X Black handle IP5X with keylock Red handle IP5X Red handle IP5X with keylock Code 4547560 725623 4547560 725609 4547560 726101 4547560 726088 4547560 725630 4547560 725616 4547560 726118 4547560 726095 Price
External Operating
Field Fit Accessory Black handle IP54 Black handle IP54 with keylock Red handle IP54 Red handle IP54 with keylock Black Handle IP65 Black Handle IP65 with keylock Red Handle IP65 Red Handle IP65 with keylock Code 4547560 727993 4547560 727832 4547560 728631 4547560 728471 4547560 728037 4547560 727870 4547560 728679 4547560 728518 Price
page 42
Order one interlock part for each MCCB and one cable between two MCCBs *Not suitable for use with CBR
Electrical Interlocks
Field Fit Accessory Cable for Electrical Interlocks, 500mm Cable for Electrical Interlocks, 1500mm Code 4547560 756405 4547560 756412 Price
page 43
TEMBREAK 2
4547560 033551
TEMBREAK 2
page 44
Interpole barriers are supplied as standard: 2 pieces per 3P MCCB, 3 pieces per 4P MCCB. For additional barriers please order individually Field Fit Accessory
Neutral Link
Field Fit Accessory 125A Neutral Link 125/250A Neutral Link Shroud Code 800481 800559 Price
page 45
TEMBREAK 2
TEMBREAK 2
125A Frame
Factory Assembled a Two TemBreak 2 MCCBs, 125A Frame b Auxillary switch for generator MCCB Auxillary switch for mains MCCB Code N/A Price
Not included
Link type mechanical interlock (left) or c Link type mechanical interlock (left, 4P) d Cable for electrical interlock (500m) Motor operator for mains MCCB
035005* 035029*
000348
000348
035012* 756405
Refer to Motor Operator Select code base on required voltage. Refer to Motor Operator Select code base on required voltage.
Wiring harness for generator MCCB Wiring harness for mains MCCB 303001001 302001001
page 46
IR (A)
Thermal Magnetic
Icu = 125kA
20-32
4547560 255410
40-63
Thermal Magnetic
Icu = 200kA
20-32
40-63
4547560 255625
4547560 255618
IR (A)
13-20* 32-50 20-32* 40-63
Icu = 36 kA
S160-NJ
4547560 326837
Thermal Magnetic
*Icu = 30 kA
4547560 326844
79-125
63-100
4547560 326851
Thermal Magnetic
Icu = 65 kA
79-125
63-100
40-63
4547560 327032
4547560 327155
Icu = 125 kA
*H125-NJ, L125-N3, H160-NJ AND L160-NJ are 103mm deep. Refer to TemBreak 2 catalogue for details.
page 47
TEMBREAK 2
In (A)
13-20 32-50 40-63 20-32
3P 4547560 327209 4547560 327223 4547560 327247 4547560 327230 4547560 327216
Price
4P 4547560 327308 4547560 327322 4547560 327339 4547560 327353 4547560 327346 4547560 327315
Price
Thermal Magnetic
Icu = 25kA
TEMBREAK 2
126-200 158-250
101-160
79-125
63-100
4547560 327278
4547560 327254
4547560 327360
Icu = 36 kA
S250-NJ
101-160
158-250 101-160
126-200
4547560 312021
4547560 312038
4547560 312052
4547560 312151
Icu = 65 kA
158-250 101-160
126-200
4547560 312250
4547560 312359
158-250
4547560 312427
4547560 312434
4547560 312533
L250-NJ *
Thermal Magnetic
Icu = 200 kA
101-160
158-250
4547560 312625
4547560 312632
4547560 312724
4547560 312731
Low Instantaneous
Model S160-NJ Icu = 36 kA *Icu = 30 kA
IR (A)
20* 32* 100 160
3P 4547560 329517 4547560 329524 4547560 329531 4547560 329500 4547560 329548
Price
4P 4547560 329616 4547560 329623 4547560 329630 4547560 329609 4547560 331039 4547560 329647
Price
Low Instantaneous
125
S160-GJ Icu = 65 kA
100 160
Low Instantaneous
125
4547560 331008
* H250-NJ and L250-NJ are 103mm. Refer to Tembreak 2 catalogue for details.
4547560 331022
4547560 331015
page 48
IR (A)
20 32
Price
Price
Low Instantaneous
100
200
160
125
250
250
Low Instantaneous
Icu = 65 kA
160 250
200
4547560 330421
IR (A)
20* 32* 50 100 125 63
Price
Price
*Icu = 30 kA
160 S160-GJ 50
Icu = 65 kA
63
4547560 328619
4547560 328718
E250-NJ
4547560 329135
S250-NJ
Icu = 36 kA
160 250
200
4547560 329302
4547560 329319
4547560 329333
Icu = 65 kA
160
200 250
4547560 329425
4547560 329418
4547560 329432
page 49
TEMBREAK 2
S250-NJ
Icu = 36 kA
160
200
4547560 330124
4547560 330223
IR (A)
16-40 16-40 16-40
Price
4P 4547560 331725 4547560 331749 4547560 331732 4547560 331756 4547560 331824 4547560 331831 4547560 337826 4547560 331848 4547560 331855 4547560 337840 4547560 337857 4547560 331947 4547560 331954
Price
100-160 4547560 337802 100-160 100-160 50-250 50-250 50-250 50-250 50-40 50-40 50-40 50-40 100-160 4547560 337819 4547560 331909 4547560 331916
TEMBREAK 2
4547560 331930
S250-GE
Icu = 65 kA
Electronic
Electronic Protection Codes: A - LSI; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
A 40 AN 40 AP 40 A 125 AN 125 AP 125 A 160 AN 160 AP 160 APN 160 A 250 AN 250 AP 250 APN 250 APN 125 APN 40
4547560 332029
100-125 4547560 332104 100-125 100-125 4547560 332111 100-125 100-160 4547560 337925 100-160 100-160 4547560 337932 100-160 100-250 4547560 332203 100-250 100-250 16-40 16-40 16-40 50-125 50-125 50-125 50-125 16-40 100-250 4547560 332210
4547560 332043
4547560 337956
4547560 337970 4547560 332227 4547560 332234 4547560 332241 4547560 332258
Icu = 70 kA
Electronic
Electronic Protection Codes: A - LSI; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
S250-PE
A 40 AN 40 AP 40 APN 40 A 125 AN 125 AP 125 APN 125 A 160 AN 160 AP 160 APN 160 A 250 AN 250 AP 250 APN 250
4547560 327728 4547560 327735 4547560 327827 4547560 327834 4547560 337926
4547560 327742 4547560 327759 4547560 327841 4547560 327858 4547560 337940
100-160 4547560 327902 100-160 100-160 4547560 327919 100-160 100-250 4547560 319006 100-250 100-250 100-250 4547560 319020
4547560 337933
4547560 337957 4547560 332227 4547560 332234 4547560 332241 4547560 332258
*Note: All electronic 250A frame models are 103mm deep. Refer to Tembreak 2 catalogue for details.
page 50
IR (A)
A 40 AN 40 AP 40 A 125 APN 40 AN 125 AP 125 APN 125 A 160 AN 160 AP 160 APN 160 A 250 AN 250 AP 250 APN 250
Price
4P 4547560 328022 4547560 328046 4547560 328039 4547560 328053 4547560 328121 4547560 328138 4547560 328220 4547560 328145 4547560 328152 4547560 338244 4547560 328251 4547560 319143 4547560 319150
Price
16-40
100-160 4547560 328206 100-160 100-160 100-250 100-250 100-160 4547560 328213 100-250 4547560 319105 100-250 4547560 328129
*Note: All electronic 250A frame models are 103mm deep. Refer to Tembreak 2 catalogue for details.
page 51
TEMBREAK 2
4547560 328237
TEMBREAK 2
Model ZE250-NJ
IR (A)
100-160 160-250
Price
4P 4547560 642906 4547560 642913 4547560 643101 4547560 643118 4547560 643309 4547560 643316
Price
Icu =25 kA
ZS250-NJ
Icu = 36kA
100-160
160-250
4547560 643002
4547560 643019
ZS250-GJ
Icu = 65kA
100-160
160-250
4547560 643200
4547560 643217
IR (A)
100-160 160-250
Price
Price
Icu =25 kA
ZS250-NJ ZP
Icu = 36kA
100-160
160-250
4547560 644207
4547560 644214
4547560 644313
ZS250-GJ ZP
Icu = 65kA
100-160
160-250
4547560 644405
4547560 644412
4547560 644504
4547560 644511
page 52
ON
ON
OFF
OFF
LOAD
3 Poles in Series
LOAD
4 Poles in Series
DC Application
Model S 160-ND @ 350V DC Icu = 10kA Thermal Magnetic S250-ND @350V DC Icu = 10kA Poles wired in series
IR (A)
20 32 50 100 125 160 160 250 63
3P 4547560 334108 4547560 334115 4547560 334122 4547560 334139 4547560 334146 4547560 334153 4547560 334160 4547560 317262 4547560 317279
Price
4P
Price
Model S 160-ND @ 500V DC Icu = 7.5kA S250-ND ThermalDC Magnetic @350V Icu = 10kA S250-ND @500V DC Icu = 7.5kA
IR (A)
20 32
3P 4547560 4547560
Price
Price 251.62
50
100
63
4547560
4547560 334221 4547560 334238 4547560 334245 4547560 334252 4547560 334269 4547560 334405 4547560 334412
160 160
125
275.58
Poles wired in series (4 Pole Version Only) Model S 160-ND @ 600V DC Icu = 5kA Thermal Magnetic S250-ND @600V DC Icu = 5kA Poles wired in series (4 Pole Version Only)
250
4547564
IR (A)
20 32
3P 4547560 4547560
Price
50
100
63
4547560
4547560 334320 4547560 334337 4547560 334344 4547560 334351 4547560 334368 4547560 334429 4547560 334436
160 160
125
275.58
250
4547560
page 53
TEMBREAK 2
TEMBREAK 2
page 54
DC 200-240V
Straight type
4 Bars (straight)
Offset type
For Removable Part of Plug-in MCCB Field Fit Accessory 3P for thermal magnetic E and S types 4P for thermal magnetic E and S types 3P for H and L types (250A) and electronic S types 4P for H and L types (250A) and electronic S types A fixed part is also required to complete the plug-in MCCB
Price
page 55
TEMBREAK 2
TEMBREAK 2
page 56
page 57
TEMBREAK 2
4547560 755774
TEMBREAK 2
Order one interlock part for each MCCB and one cable between two MCCBs *Not suitable for use with CBR
Electrical Interlocks
Field Fit Accessory Cable for Electrical Interlocks, 500mm Cable for Electrical Interlocks, 1500mm Code 4547560 756405 4547560 756412 Price
page 58
Field Fit Accessory 3P , 1 cover for thermal magnetic E and S types 4P , 1 cover for thermal magnetic E and S types 3P , 1 cover for H and L types and electronic S types , 1 cover for H and L types and electronic S types 4P Terminal cover lock
Code 4547560 080456 4547560 080463 4547560 080654 4547560 080661 4547560 038006
Price
page 59
TEMBREAK 2
Interpole barriers are supplied as standard: 2 pieces per 3P MCCB, 3 pieces per 4P MCCB. For additional barriers please order individually.
TEMBREAK 2
page 60
250A Frame
Factory Assembled a Two TemBreak 2 MCCBs, 250A Frame b Auxillary switch for generator MCCB Auxillary switch for mains MCCB Code N/A Price
Not included
Link type mechanical interlock (left) or c Link type mechanical interlock (left, 4P) d Cable for electrical interlock (500m) Motor operator for mains MCCB
035104* 035128*
000348
000348
035111* 756405
Wiring harness for generator MCCB Wiring harness for mains MCCB 303001001 302001001
page 61
TEMBREAK 2
4 pole
185 103 4P
TEMBREAK 2
IR (A)
158-250 252-400 158-250 252-400 158-250 252-400 158-250 252-400
4547560 378560 4547560 378577 4547560 378645 4547560 378652 4547560 378843 4547560 378850 4547560 379048 4547560 379055
Model
AN AP A APN AG AN AP
APGN A
100-250 100-250 100-250 100-250 160-400 160-400 160-400 160-400 160-400 160-400 160-400 160-400 100-250 100-250 100-250 100-250 160-400 160-400 160-400 160-400 160-400 160-400 160-400 160-400
IR (A)
4547560 -4547560 -4547560 4547560 -4547560 -4547560 --4547560 -4547560 -4547560 4547560 -4547560 -4547560 ---
3P
Price
--
4547560 379703 4547560 379727 4547560 379710 4547560 379734 4547560 379741 4547560 379765 4547560 379758 4547560 379789 4547560 379772 4547560 379796 4547560 379901 4547560 379925 4547560 379918 4547560 379932 4547560 379949 4547560 379963 4547560 379956 4547560 379987 4547560 379970 4547560 379994
4P
Price
--
AN AP A APN AG AN AP
APGN
page 62
page 35
IR (A)
A AN AP APN A AG AN AP AGN APG APN APGN
3P
Price
4P 4547560 364921 4547560 372803 4547560 364938 4547560 372810 4547560 372827
Price
Electronic
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
Icu = 125 kA
H400-NE
100-250 4547560 364907 100-250 4547560 364945 100-250 160-400 4547560 364914 160-400 160-400 160-400 160-400 100-250 4547560 365003 100-250 4547560 365041 100-250 160-400 4547560 365010 100-250 100-250
4547560 372889 4547560 372872 4547560 372896 4547560 365027 4547560 372902 4547560 365034
L400-NE
Electronic
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
Icu = 200 kA
4547560 372919
4547560 372926
160-400 4547560 365089* 160-400 160-400 160-400 4547560 365072 160-400 4547560 365096* 160-400 160-400
4547560 372957
page 63
TEMBREAK 2
4547560 372858
4547560 372865
IR (A)
3P
Price
Price
100-250 4547560 390678* 100-250 4547560 390692* 100-250 4547560 390715* 160-400 4547560 390784 160-400 160-400 160-400
TEMBREAK 2
4547560 391026
4547560 391033 4547560 391057 4547560 391071 4547560 391866 4547560 391873 4547560 391897 4547560 391910
A AG AGN APGS APGNS APGSCWH APGNSCWH A AG AGN APGS APGNS APGSCWH APGNSCWH
100-250 4547560 391637* 100-250 4547560 391651* 100-250 4547560 391675* 160-400 4547560 391743 160-400 160-400 160-400
4547560 391989
4547560 391996 4547560 392016 4547560 392030 4547560 393785 4547560 393792 4547560 393815 4547560 393839
A AG AGN APGS APGNS APGSCWH APGNSCWH A AG AGN APGS APGNS APGSCWH APGNSCWH
100-250 4547560 393556* 100-250 4547560 393570* 100-250 4547560 393594* 160-400 4547560 393662 160-400 160-400 160-400
4547560 393907
Electronic Protection Codes: A - LSI; P - Pre-trip alarm; G - Ground fault trip N - N-phase protection; S - Phase rotation protection C - Communication function; W - Electrical energy pulse; H - Harmonic current
*An external neutral CT must be ordered for ground fault trip function.
page 64
IR (A)
3P
Price
Price
100-250 4547560 395475* 100-250 4547560 395499* 100-250 4547560 395512* 100-250 395581
160-400 160-400
395598*
*An external neutral CT must be ordered for ground fault trip function.
page 65
TEMBREAK 2
160-400
4547560 395826
TEMBREAK 2
IR (A)
252-400 158-250 158-250
Price
Price
Icu = 25kA
Thermal Magnetic S400-CJ
E400-NJ
Icu = 36 kA
252-400
4547560 380914
4547560 380938
Icu = 50 kA
158-250
252-400
4547560 381119
4547560 381102
4547560 381126
4547560 381133
Icu = 65 kA
158-250
252-400
4547560 381317
4547560 381300
4547560 381324
4547560 381331
Thermal Magnetic
Low Instantaneous
Model E400-NJ Icu = 25kA Low Instantaneous S400-CJ Icu = 36 kA Low Instantaneous S400-NJ Icu = 50 kA Low Instantaneous S400-GJ Icu = 65 kA Low Instantaneous
IR (A)
252-400
3P 4547560 383120
Price
4P 4547560 TBA
Price
252-400
4547560 383175
4547560 383182
252-400
4547560 383236
4547560 383243
252-400
4547560 383335
4547560 383342
page 66
ON
OFF
3 Poles in Series
DC Application
Model S400-ND 350V DC Icu = 20kA Thermal Magnetic Poles wired in series
IR (A)
250 400
Price
Model S400-ND 500V DC Icu = 15kA Thermal Magnetic Poles wired in series
IR (A)
250 400
Price
Model S400-ND 600V DC Icu = 15kA Thermal Magnetic Poles wired in series
IR (A)
250 400
Price
page 67
TEMBREAK 2
LOAD
IR (A)
A AN AP APN A AG AN AP AGN APG APN APGN A AN AP APN A AG AN AP AGN APG APN APGN
3P
Price
4P 4547560 373206 4547560 373213 4547560 373305 4547560 373220 4547560 373237
Price
Icu = 125kA
Electronic
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
100-250 4547560 373008 100-250 4547560 373015 100-250 160-400 4547560 373107 160-400 160-400 160-400 160-400 100-250 4547560 373503 100-250 4547560 373510 160-400 4547560 373602 160-400 100-250 160-250 100-250
TEMBREAK 2
4547560 373312
4547560 373329 4547560 373343 4547560 373336 4547560 373350 4547560 373701 4547560 373718 4547560 373800
L400-NE
Electronic
Icu = 200 kA
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
4547560 373817
page 68
IR (A)
A AN AP APN A AG AN AP AGN APG APN APGN A AN AP APN A AG AN AP AGN APG APN APGN
3P
Price
4P 4547560 373244 4547560 373251 4547560 373367 4547560 373268 4547560 373275
Price
Electronic
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
Icu = 125kA
100-250 4547560 373022 100-250 4547560 373039 100-250 160-400 4547560 373145 160-400 160-400 160-400 100-250
160-400 4547560 373169* 160-400 4547560 373152 160-400 4547560 373176* 160-400 100-250 4547560 373527 100-250 4547560 373534 160-400 4547560 373640 160-400 160-400 100-250 100-250
4547560 373374
4547560 373381 4547560 373404 4547560 373398 4547560 373411 4547560 373749
L400-NE
Electronic
Icu = 200 kA
4547560 373763
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
4547560 373770
4547560 373886
4547560 373879
160-400 160-400
page 69
TEMBREAK 2
IR (A)
A AN AP APN A AG AN AP AGN APG APN APGN A AN AP APN A AG AN AP AGN APG APN APGN
3P
Price
4P 4547560 373282 4547560 373299 4547560 373428 4547560 373084 4547560 373091
Price
Electronic
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
Icu = 125kA
H400-NE
100-250 4547560 373046 100-250 4547560 373053 100-250 160-400 4547560 373183 160-400 160-400 160-400 160-400 100-250 4547560 373541 100-250 4547560 373558 160-400 4547560 373688 160-400 100-250 100-250 100-250
TEMBREAK 2
4547560 373435
L400-NE
Electronic
Icu = 200 kA
4547560 373565
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
4547560 373572
4547560 373930
page 70
185
Model E630-NE
IR (A)
A AG AN AP AGN APG APN APGN A AG AN AP AGN APG APN APGN A AG AN AP AGN APG APN APGN
3P
Price
4P 4547560 380242 4547560 380266 4547560 380280 4547560 380273 4547560 380297 4547560 380341 4547560 380365 4547560 380389 4547560 380372 4547560 380396 4547560 380440 4547560 380464 4547560 380488 4547560 380471 4547560 380495
Price
Electronic
Icu = 36 kA
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
252-630
4547560 380259
S630-CE
Electronic
Icu = 50 kA
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
252-630
4547560 380358
S630-GE
Electronic Protection Codes: A - Standard relay with LSI characteristic; P - Preferential Trip Alarm; G - Ground Fault; N - Neutral Protection
Electronic
Icu = 70 kA
252-630
4547560 380457
page 71
TEMBREAK 2
103
IR (A)
630 630 630
Price
4P 4547560 397585 4547560 397592 4547560 397615 4547560 397639 4547560 398087 4547560 398094 4547560 398117 4547560 398131 4547560 398582 4547560 398599 4547560 398612 4547560 398636
Price
TEMBREAK 2
630
630
4547560 397967
4547560 397974*
630
630
4547560 397967
4547560 398476*
*An external neutral CT must be ordered for ground fault trip function.
page 72
Electronic Protection Codes: A - LSI; P - Pre-trip alarm; G - Ground fault trip; N - N-phase protection; S - Phase rotation protection; C - Communication function; W - Electrical energy pulse; H - Harmonic current
Price
page 73
TEMBREAK 2
TEMBREAK 2
DC 200-240V
Flat Bars Field Fit Accessory 3 bars, 400A (Offset) 3 bars, 400A (Straight)
Price
Straight type
Offset type
Flat Bar Studs Field Fit Accessory 3 studs, 400A 4 studs, 400A 3 studs, 630A 4 studs, 630A
Price
Rear connections for H400 and L400 models are factory fitted. Item numbers for MCCBs complete with rear connections can be found under "400A Frame MCCBs with Rear Connections Fitted"
Price
Plug-in conversions for H400 and L400 models are factory fitted. Item numbers for MCCBs complete with plug-in conversions can be found under "400A Frame MCCBs with Plug-in Connections Fitted" A fixed part is also required to complete the plug-in MCCB
page 74
Plug for Removable Part of MCCB, 3 terminals Field Fit Accessory Plug for auxiliary switches and alarm switches Plug for shunt trips and undervoltage trips Order one plug for each internal accessory
Price
Cable clamps for H400 and L400 models are factory fitted. Item numbers for MCCBs complete with cable clamps can be found under "400A Frame MCCBs with Cable Clamps Fitted"
page 75
TEMBREAK 2
TEMBREAK 2
page 76
Order one interlock part for each MCCB and one cable between two MCCBs
Electrical Interlocks
Field Fit Accessory Cable for Electrical Interlocks, 600mm Cable for Electrical Interlocks, 2100mm Code 4547560 756429 4547560 756436 Price
page 77
TEMBREAK 2
TEMBREAK 2
Terminal Covers for Rear Connection, Cable Clamps and Plug-In (CR)
Field Fit Accessory 3P , 1 cover (narrow type) 4P , 1 cover (narrow type) , 1 cover 3P , 1 cover 4P Terminal cover lock Code 4547560 081002 4547560 081019 4547560 080807 4547560 080814 4547560 038006 Price
Interpole barriers are supplied as standard: 2 pieces per 3P MCCB, 3 pieces per 4P MCCB. For additional barriers please order individually
page 78
Price
OCR Checker
Field Fit Accessory OCR Checker 100-120V AC OCR checker 200-240V AC Code 756306 756313 Price
Neutral Link
Field Fit Accessory 400A Neutral Link 630A Neutral Link 400/630 Neutral Link Shroud Code 800504 800511 800566 Price
page 79
TEMBREAK 2
External Neutral CT
TEMBREAK 2
Link type mechanical interlock (left) or c Link type mechanical interlock (left, 4P) d Cable for electrical interlock (500m) Motor operator for mains MCCB
000348
000348 035265
035272 756405
035289
Wiring harness for generator MCCB Wiring harness for mains MCCB 303001001 302001001
page 80
4 pole
280 103
280
Model XS800NJ
I cu
= 65 kA
504-800
397-630
IR (A)
3P 206520580 206520563
Price
4P 206520780 206520763
Price
Icu = 50 kA
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
318-630
318-630
206570563 206571563
206575763
206570763 206571763 206572763 206570780 206571780 206572780 206576763 206581763 206582763 206576780 206581780 206582780 206521740
403-800
206571580
206575780
Icu = 65 kA
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
XH800SE
318-630
318-630
206581563
206585763
403-800
206581580
206585780
Icu = 100 kA
XH800PJ
Thermal Magnetic
504-800
397-630
252-400
206521563
206521540 206521580
206521780
206521763
page 81
TEMBREAK 2
140
Icu = 65 kA
A AG AI AP A AG AI AP
318-630
IR (A)
3P 206527563 206525563*
Price
4P 206525763 206527763 206526763 206528763 206525780 206527780 206526780 206528780 206516563 206516763 206518763 206524780 206529780 206516780 206518780
Price
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
318-630
318-630
206528563 206527580
206526563
TEMBREAK 2
403-800
Icu = 125 kA
A AG AI AP A AG AI AP
318-630 318-630
318-630
206529563 206516563
206524563*
206524763
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
206518563 206529580
403-800
page 82
Auxiliary/Alarm Switches
Code 1 Alarm 1 Auxiliary 1 Auxiliary, 1Alarm 2 Auxiliaries 2 Auxiliaries, 1 Alarm 2 Auxiliaries, 2 Alarms 3 Auxiliaries 3 Auxiliaries, 1 Alarm 215001070 215001005 215001042 Price
Shunt Trips
Code AC 100-115V AC 200-480V AC 24V AC 48V DC 12V DC 24V DC 48V DC 100-115V DC 200-230V DC 60V DC 125V DC 30V 215002006 215002014 215002146 215002156 215002024 215002032 215002040 215002051 215002059 215002164 215002198 215002190 Price
page 83
TEMBREAK 2
215001015
UnderVoltage Trips
Code AC 100-120V AC 100-120V TIME DELAY AC 100-120V 1SEC TIME DEL 215002067 215002119 215002243 215002253 215002075 215002127 215002206 215002215 215002313 215002083 215002135 215002226 215002235 215002101 215002111 215002093 215002173 215002181 Price
TEMBREAK 2
AC 100-120V 2SEC TIME DEL AC 200-240V AC 200-240V TIME DELAY AC 200-240V 1SEC TIME DEL AC 200-240V 2SEC TIME DEL (IND) 240V AC 380-450V AC 380-450V TIME DELAY AC 380-450V 1SEC TIME DEL AC 380-450V 2SEC TIME DEL DC 100-115V DC 200-230V DC 24V DC 48V DC 60V
page 84
Code 4 Pole 4 extension Bars (630A) 4 extension Bars (800A) Drawout conversion kit (630A)* Drawout conversion kit (800A)* 4 cable clamps 4 rear connection studs (top) 4 rear connection studs (bottom) Plug in conversion kit (630A)** Plug in conversion kit (800A)** Auxiliary connector plug for plug in and drawout** *Drawout chassis and auxiliary connectors must be ordered separately ** Plug in base and auxiliary connectors must be ordered separately *** Auxiliary connector socket must be ordered separately 215003358 215003360 215003247 215003256 215003193 215003116 215003104 215003142 215003144 215003072
Price
page 85
TEMBREAK 2
215003251
TEMBREAK 2
DC 110V
Terminal Covers
Code 3 Pole 2 covers for front connection 2 interpole barriers 2 covers for rear connection and plug in 215004018 215004042 215004024 Price
Code 4 Pole 2 covers for front connection 2 interpole barriers 2 covers for rear connection and plug in 215004019 215004043 215004025
Price
Drawout Chassis
Code 3P 4P 3P 4P Drawout Chassis 630A Drawout Chassis 630A Drawout Chassis 800A Drawout Chassis 800A 215014021 215014028 215014036 215014045 Price
page 86
215005035 215005227 215005235 215005243 215005251 215005195 215005203 215005211 215005219 215005259 215005267 215005275 215005283 215005156 215005160
Plug-in Bases
Code 3 Pole Plug In Base Plug In Base with extension bars IP20 Plug in base IP20 Plug in base with extension bars Auxiliary connector socket for plug in 215007039 215007011 215007069 215007021 215007049 Price
page 87
TEMBREAK 2
215005381
TEMBREAK 2
IP20 Plug in base with extension bars Auxiliary connector socket for plug in
Mechanical Interlocks
Code 3 Pole Front Mechanical Interlock Rear Mechanical Interlock 1m Wire Mechanical Interlock 1.5m wire mechanical interlock Rear Mech Interlock+accessory terminals* Rear Mech Interlock+TemTransfer terminal* Rear Mechanical Interlock for Plug in+accessory terminals* TemTransfer Automatic Changeover Controller *Includes backplate and mounting frame Code 4 Pole Front Mechanical Interlock Rear Mechanical Interlock 1m Wire Mechanical Interlock 1.5m wire mechanical interlock Rear Mech Interlock+accessory terminals* Rear Mech Interlock+TemTransfer terminals* Rear Mechanical Interlock for Plug in+accessory terminals* TemTransfer Automatic Changeover Controller *Includes backplate and mounting frame 215009006 215009024 215009035 215009040 215009061 215009139 215009045 302001001 Price 215009005 215009023 215009035 215009040 215009060 215009138 215009080 302001001 Price
page 88
Handle Locks
Code Handle Lock Handle Extension Adjustment Seal Facility 215011004 215011007 215011014 Price
Neutral Link
Code 800A Neutral Link 800A Neutral Link Shroud 800528 215020005 Price
page 89
TEMBREAK 2
4 pole
280 120
280 140
(mm)
TEMBREAK 2
Model XS1250CE
IR (A)
A AG AI AP A AG AI AP A AG AI AP A AG AI AP A AG AI AP A AG AI AP
Price
4P 206665710 206660710 206661710 206662710 206665712 206660712 206661712 206662712 206670710 206671710 206672710 206675712 206670712 206671712 206672712 206629710 206626710 206628710 206625712 206629712 206626712 206628712
Price
Icu = 50 kA
Electronic protection codes: A - LSi; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
1000
1000
XS1250SE
Icu = 85 kA
504-1000
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
504-1000
504-1000
206672510 206670512
206671510
206675510*
206675710
630-1250
TL1250NE(1600A Frame)
Icu = 125 kA
504-1000 504-1000
504-1000
206629510 206626510
206625510*
206625710
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
206628510 206629512
630-1250
page 90
(mm)
120
Model XS1600CE
Icu = 50 kA
A AG AI AP A AG AI AP A AG AI AP
806-1600 FC
IR (A)
4P
Price
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
206765616*
206765916*
206765016
XS1600SE
Icu = 100 kA
A AG AI AP A AG AI AP A AG AI AP
206770516
206775716
206770716
Electronic protection codes: A - Standard relay with LSI characteristic ; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
206775616*
206775916*
206775016
FC - with front connections; RC - with rear connections; DO - with drawout connections * An external Neutral CT must be ordered. See External Accessories.
page 91
TEMBREAK 2
Auxiliary/Alarm Switches
Code 3 Pole 1 Alarm 1 Auxiliary 212001071 212001006 212001043 212001016 212001053 212001102 212001026 212001101 Code 4 Pole 1 Alarm 1 Auxiliary 1 Auxiliary, 1Alarm 2 Auxiliaries 2 Auxiliaries, 1 Alarm 2 Auxiliaries, 2 Alarms 3 Auxiliaries 3 Auxiliaries, 1 Alarm 212001072 211001007 212001044 212001017 212001054 212001104 212001027 212001103 Price Price
TEMBREAK 2
1 Auxiliary, 1Alarm 2 Auxiliaries 2 Auxiliaries, 1 Alarm 2 Auxiliaries, 2 Alarms 3 Auxiliaries 3 Auxiliaries, 1 Alarm
Shunt Trips
Code AC 100-115V AC 200-480V AC 24V AC 48V DC 100-115V DC 12V DC 125V DC 200-230V DC 24V DC 30V DC 48V DC 60V 212002007 212002015 211002147 211002157 212002052 211002025 212002199 212002060 212002033 212002191 212002041 211002165 Price
page 92
211002254 212002076 212002128 212002208 211002216 211002314 211002084 212002136 211002228 211002236 212002102 212002112 212002094 212002174 212002183
page 93
TEMBREAK 2
211002244
TEMBREAK 2
IP20 Plug In Conversion kit* Drawout Conversion kit** Auxiliary connector plug for plug in and drawout***
1250A 4 Pole 8 rear connection studs 4 rear connection bars (bottom) 4 rear connection bars (top) IP20 Plug In Conversion kit* Drawout Conversion kit** Auxiliary connector plug for plug in and drawout***
Price
1600A 3 Pole 3 rear connection bars (bottom) 3 rear connection bars (top)
Price
1600A 4 Pole 4 rear connection bars (bottom) 4 rear connection bars (top) *Drawout chassis and auxiliary connectors must be ordered separately ** Plug in base and auxiliary connectors must be ordered separately *** Auxiliary connector socket must be ordered separately
Price
page 94
212008044
Terminal Covers
1250A 3 Pole 2 covers for front connection 1 cover for front connection Code 211004020 211004070 Price
1250A 4 Pole 2 covers for front connection 1 cover for front connection
Price
Drawout Chassis
1250A 3 Pole 4 Pole Drawout Chassis Drawout Chassis Code 211014053 211014061 Price
page 95
TEMBREAK 2
211008077
TEMBREAK 2
Door Mounted Red handle IP65 (TemBreak 2) Door Mounted Handle Left:Black Breaker mounted Handle Left:Black Breaker mounted:IP55 Handle Left:Red/Yellow Breaker mounted Handle Left:Red/Yellow Breaker mounted:IP55 Handle Right:Black Breaker mounted Handle Right:Black Breaker mounted :IP55 Handle Right:Red/Yellow Breaker mounted Handle Right:R/Y Breaker mounted:IP55 Handle Upper:Black Breaker mounted Handle Upper:Black Breaker mounted:IP55 Handle Upper:Red/Yellow Breaker mounted Handle Upper:R/Y Breaker mounted:IP55 Handle OHE:Handle Mechanism Door Flange
Plug-in Bases
1250A 3 Pole Plug In Base IP20 Plug In Base Auxiliary connector socket for plug in base Code 211007041 211007071 215007049 Price
1250A 4 Pole Plug In Base IP20 Plug In Base Auxiliary connector socket for plug in base
Price
page 96
Mechanical Interlocks
1250A 3 Pole Front Mechanical Interlock Rear Mechanical Interlock Rear Mechanical Interlock + Accessory terminals* Rear Mechanical Interlock + TemTransfer terminals* 1M Wire mechanical interlock 1.5M Wire mechanical interlock Rear mechanical interlock for plug in + accessory terminals* TemTransfer Automatic Changeover Controller *Includes backplate and mounting frame Code 211009007 211009025 211009028 211009140 211009036 211009041 211009081 302001001 Price
1250A 4 Pole Front Mechanical Interlock Rear Mechanical Interlock Rear Mechanical Interlock + Accessory terminals* Rear Mechanical Interlock + TemTransfer terminals* 1M Wire mechanical interlock 1.5M Wire mechanical interlock Rear mechanical interlock for plug in + accessory terminals* TemTransfer Automatic Changeover Controller *Includes backplate and mounting frame
Price
page 97
TEMBREAK 2
215006004
TEMBREAK 2
Rear Mechanical Interlock + TemTransfer terminals 1M Wire mechanical interlock 1.5M Wire mechanical interlock TemTransfer Automatic Changeover Controller (Optional)
1600A 4 Pole Front Mechanical Interlock Rear Mechanical Interlock Rear Mechanical Interlock + Accessory terminals Rear Mechanical Interlock + TemTransfer terminals 1M Wire mechanical interlock 1.5M Wire mechanical interlock TemTransfer Automatic Changeover Controller (Optional)
Price
Castell Locks
Code Castell A Lock In Close Castell B Lock In Close Castell A Lock In Open Castell B Lock In Open Castell Lock XFH Handle CAM FOR XFH Handle Castell Lock XFH SP Handle Castell SPEC Lock In Close Castell SPEC Lock In Open 211010013 211010025 211010059 211010070 215010100 215010102 215010107 211010048 211010097 Price
page 98
Neutral Link
Code 1000A Neutral Link 1000A Neutral Link Shroud 800535 211020006 Price
page 99
TEMBREAK 2
TEMBREAK 2
XS2000NE
Icu = 85kA
A AG AI AP A AG AI AP
2000FC 204850520 2000FC 204851520 2000FC 204852520 2000RC 204850620 2000RC 204851620 2000RC 204852620 2500RC 204950625 2500RC 204951625
IR (A)
3P
Price
2000FC 204855520*
204851720
204855720
204850720
4P
Price
204852720 204855820
2000RC 204855620*
XS2500NE
Icu = 85kA
A AG AI AP
204955825
page 100
Electronic Protection Codes: A - LSI; P - Preferential trip alarm; G - Ground fault; I - Fault indication LEDs
Key to MCCB connection codes: FC - with front connections; RC - with rear connections *An external Neutral CT must be ordered. See External Accessories. Contact Terasaki for details of accessories for 2000A and 2500A frame MCCBs.
103
140
140
225
Model XS1000ND (800A Frame) Icu = 20kA @ 500V DC Icu = 20kA @ 600V DC Thermal Magnetic XS1250ND (Front Connected) Icu = 50kA @ 500V DC Icu = 20kA @ 600V DC Magnetic Only XS1600ND (Front Connected) Icu = 50kA @ 500V DC Icu = 20kA @ 600V DC Magnetic Only XS2000ND (Front Connected) Icu = 50kA @ 500V DC Icu = 20kA @ 600V DC Magnetic Only XS2000ND (Rear Connected) Icu = 50kA @ 500V DC Icu = 20kA @ 600V DC Magnetic Only XS2500ND (Rear Connected) Icu = 50kA @ 500V DC Icu = 20kA @ 600V DC Magnetic Only XS3200ND (Rear Connected) Icu = 50kA @ 500V DC Icu = 20kA @ 600V DC Magnetic Only 1000
In (A)
3P 206640510
Price
1250
206645512
1600
206740516
2000
206840520
2000
206840620
2500
206940625
32500
206940632
page 101
TEMBREAK 2
1250A 1600A
2000A 2500A
Price
Price
Shunt Trips
Factory Fit Accessory Shunt Trip (110/240V AC, 24/48/110/220V DC) Price Price Price
Motor Operators
Factory Fit Accessory Motor Operator (110/220V AC, 110V DC) Price Price Price
Terminal Covers
Field Fit Accessory Terminal Cover FC 3P Price Price Price
Handles
Factory Fit Accessory Handle Operator OHJ Castell for MCCB Handle Operator OHE Price Price Price
Handle Operator OHH Castell for OHH Handle Handle Lock Door Flange
page 102
In
125 160
Icm
3.6 6 6
Price
Price
S630-NN
S400-NN
S250-NN
630
400
250
4547560 381607
4547560 381553
4547560 316005
4547560 381621
4547560 381577
In
1250 800
Icm
32 15
3P 206690512 206590580
Price
4P 206590780 206690712
Price
XS1600NN RC
XS1600NN FC
XS1600NN DO
1600
1600
1600
45
45
45
206790616
206790516
206790716
206790916
206790016
206790816
page 103
TEMBREAK 2
page 104
page 105
TEMPOWER 2
page 106
Common Accessories
Protection Relays Switch Disconnector (Non-Auto) Protection Relay LSI (AGR-11BL-AL) Protection Relay LSIG (AGR-11BL-GL) Electrical Accessories Motor Operator Closing Coil Shunt Trip UVT Switches 7 Aux Switches 10 Aux Switches Position Switch 2 off Position switch 4 off Locking & Interlocking Accessories Mechanical Interlock 2 ACBS Mechanical Interlock 3 ACBS Door Interlock Castel Lock Facility
Standard Specification includes: Padlockable Mechanical Close & Open Buttons Mechanical Close & Open Indicators Mechanical Indication of Spring Charged/Discharged State 4AB Auxiliary Contacts Terminal Cover IP20 Door Flange Horizontal or Vertical Busbar Connections Spring Charged Main Circuit Shutters Control Circuit Shutters Position Indicator Drawout Handle
page 107
TEMPOWER 2
2. RELIABILITY
DoubleBreak contacts increase service life. Electrical and mechanical endurance ratings are the best available, and exceed the requirements of IEC 60 947-2.
TEMPOWER 2
0SCF0692
page 108
7. PROTECTION CHARACTERISTICS
TemPower2 offers time-current characteristics to 3 different standards; IEC 60 947-2 (low voltage circuit breakers) IEC 60 255-3 (electrical relays) Lloyds Register of Shipping (for marine generator protection) All models have LSI protection. TEMPOWER 2
9. DOUBLE NEUTRALS
How do you make a system harmonic proof in the face of increasing triple-N harmonic currents? Terasaki have launched the first Double Neutral ACB. The AH-60DN will carry 10,000A of neutral current.
page 109
Selection Procedure 1) Select a fixed ACB OR a Drawout body + Chassis 2) Select Top & Bottom connections 3) Select a Protection Relay 4) Select accessories according to specification
Rated Current
ACB Type
No Poles
Fixed Body
Drawout Body
Drawout Chassis
TEMPOWER 2
800A
AR208S
65kA
3 4
1250A
AR212S
65kA
3 4
1600A
AR216S
65kA
3 4
2000A
AR220S
65kA
3 4
2500A
AR325S
85kA
3 4
3200A
AR332S
85kA
3 4
4000A AR440SB
100kA
3 4
5000A
AR650S
120kA
3 4
6300A
AR663S
120kA
3 4
page 110
Selection Procedure 1) Select a fixed ACB OR a Drawout body + Chassis 2) Select Top & Bottom connections 3) Select a Protection Relay 4) Select accessories according to specification
Rated Current
ACB Type
Drawout Body
Drawout Chassis
1250A
AR212H
3 4
1600A
AR216H
80kA
3 4
1600A
AR316H
100kA
3 4
2000A
AR220H
80kA
3 4
2000A
AR320H
100kA
3 4
2500A
AR325H
100kA
3 4
3200A
AR332H
100kA
3 4
page 111
TEMPOWER 2
No Protection Non-Automatic
LIST PRICE
171.17
Protection Relay
Protection Characteristic
Trip Indication
Manual Reset
2
NP
REF
OH
NS
UV
PTA2
MRST
Dial Type
TEMPOWER 2
AGR-21BL-PS
AGR-21BL-PG (LSIG)
AGR-21BR-PS AGR-21BR-PG AGR-21BS-PS AGR-22BS-PR AGR-31BL-PS AGR-31BL-PG AGR-31BR-PS AGR-31BR-PG AGR-31BS-PS AGR-31BS-PR
(LSI) (LSIG) (LSI) (LSI) (LSI) (LSIG) (LSI) (LSIG) (LSI) (LSI)
Note 1 - Only one function can be selected from REF, OH, NS or Trip Indication. Note 2 - Only one function can be selected from UV, Spring Charge Indication or PTA2. For Earth Leakage Protection please contact Terasaki.
3 Pole ACBs with Ground Fault or Neutral Phase Protection will require one AUX CT. 3 Pole ACBs with Restricted Ground Fault will require two AUX CTs.
A = LSI PROTECTION. G = A + UNRESTRICTED GROUND FAULT PROTECTION. P = A + PRE TRIP ALARM. R = REVERSE POWER. All AGR-B Protection Relays have individual operation contact indicators except the AGR-11B, which has a single operation contact indicator.
page 112
ACCESSORY SELECTION
INDICATION ACCESSORIES AND ELECTRICAL OPERATION ACCESSORIES
INDICATION ACCESSORIES 4AB Auxiliary Switches 7AB Auxiliary Switches 10AB Auxiliary Switches Standard
ELECTRICAL OPERATION ACCESSORIES Continuously Rated Shunt Trip Double Shunt Trip 24V DC & 240V AC
Shunt trip with redundant coil for emergency use. Uses two of the ACBs auxiliary switches. Contact Terasaki for other voltages.
Used to trip an ACB within a limited time period when the mains fails.
This output contact is used to indicate the closing springs have been fully charged
Continuously Rated Closing Coil Double Closing coil 24V DC & 240V AC
Closing coil with redundant coil for emergency use. Contact Terasaki for other voltages.
page 113
TEMPOWER 2
ACCESSORY SELECTION
EXTERNAL ACCESSORIES
EXTERNAL ACCESSORIES Door Flange IP31 Test Jumper
Allows ON-OFF tests to be carried out when the ACB body is drawn out from the chassis.
An IP 55 cover is a heavy-duty clear plastic assembly with a hinged door. IP 55 Protection defined by IEC 60529.
POA
TEMPOWER 2
The Lifter Loader is designed specifically to raise, lower and manoeuvre the body to the chassis for the insertion or withdrawal in a safe and secure manner.
An IP3X cover offers protection against objects touching live terminals at the rear of the chassis when the body is withdrawn.
Lifting Plates
Detachable tools that can be used to lift the ACB body out of the chassis.
Storage location for drawout handle. Hinged handle which can be stowed on the front of the ACB with the door closed.
OCR Checker
Fixing bolts should be used if the ACB is being subjected to strong vibration, typically encountered during Marine applications
Auto-Discharge Device
This device allows the charged closing springs to be automatically released when the ACB is drawn out from the ISOLATED to the REMOVED position.
Locking system which prevents the body being inserted into the wrong chassis
Open/Close Counter
Mechanical readout that shows the number of ON-OFF cycles the ACB has performed.
page 114
ACCESSORY SELECTION
LOCKING AND INTERLOCKING SYSTEMS
LOCKING AND INTERLOCKING SYSTEMS Door Interlock Prevents the switchboard door from being opened unless the breaker body is in the ISOLATED position. Please specify whether standard drawout handle or storage drawout handle is required. (Storage handle will incur extra cost) Shutter Padlock Device This device allows the main shutters to be locked when the body has been removed. AR208 - AR332 AR440
Cylinder Lock and Key Castell Lock and Key (factory fitted) Lock in Off Position Castell Facility
MECHANICAL INTERLOCKING For Horizontal Interlocking 2 ACB's Interlocking Type-C 1 = Closed 0 = Open Breaker 1 0 1 Breaker 2 1 0
Interlocking is possible between any frame size within the TemPower 2 range
Total Price
Interlocking Type-A
1 = Closed 0 = Open
1 = Closed 0 = Open
Total Price
Total Price
Vertical Interlocking 2 ACBs Vertical Mechanical Interlocking is available between 2 ACBs Minimum Pitch - 550mm Maximum Pitch - 1200mm
TemTransfer This is a fully configurable automatic supply transfer unit. It is designed to monitor the incoming AC mains supply for over/under voltage and over/under frequency. Should these fall out of the set limits, the TemTransfer will switch the loads from the mains to a generator.
Total Price
TemTransfer
Total Price
page 115
TEMPOWER 2
PAGE 1 OF 2
EMAIL ADDRESS: ORDER NUMBER: QUANTITY: DELIVERY TIME REQUEST :
FOR EXAMPLE AR 325
1.TemPower 2 ACB: Enter your choice in the boxes provided (Refer to the catalogue for ratings and specfications)
'H' TYPES ARE ONLY AVAILABLE ON 1250A TO 3200A ACBS AND 'SB' TYPE ON THE 4000A ACB
Drawout Pattern.
Control Circuit Terminal Cover Main Circuit Shutters Control Circuit Shutters Std Std Std
Vertical
Front
Protection Functions
AL AS PS GL GS PG PR
AGR-11BL
-------------------------------------------------------------
----------
----------------
---------------------------------------------DC48V
-------------
-------------------
-------------------
-------------------
----------------
----
Protection Options
N-Phase Protection -NP. S1-Contact Temperature Monitoring - OH. S1-Trip Indicator. S1-Phase Rotation Protection - NS. S1-Restricted Ground Fault - REF. N4
S2-Second Pre -Trip Alarm - PTA2. S2-Undervoltage Alarm - UV. S2-Spring Charge Indicator. Zone Interlock - Z. Communication - C. External Display. Earth Leakage - ELT. Please specify control voltage
AC100-120V
---N2 N2 N2 N2 N2 N2 N2 N2 N2 N2
----
---N2
---N2 N2 N2 N2 N2
----
------------------------AC200-240V
------N3 N3 N3
N2 N2
---------N3 N3 N3
----------------
---------------DC24V
---N3 N3 N3 N3
N1
N1 N1 DC100-25V
N1 N1
N1
----
---DC200-250V
Example of AGR Description AGR KEY: Protection Relay Family. Protection Relay Group. Protection Function and Indication.
A = LSI PROTECTION. G = A + UNRESTRICTED GROUND FAULT PROTECTION. P = A + PRE TRIP ALARM. R = REVERSE POWER.
All AGR-B Protection Relays have individual operation contact indicators except the AGR-11B, which has a single operation contact indicator.
For AGR-31B please state system voltage - 21BL -P S Specify generator full load current (In) if applicable Back lit LCD for AGR-21B, 22B (option)
Volts Amps
NOTES: N1 - Soon to be available. N2 - Only one function can be selected from section S1. N3 - Only one function can be selected from section S2. N4 - Restricted Ground Fault only available with PG function.
Std
2 Position Switches (Write a '0', '1' or a '2', total 2) 4 Position Switches (Write a '0', '1' or a '2', total 4) Non-Auto Trip Indication Switch-Normal (Not Ready to Close ) Non-Auto Spring Charge Switch-Normal Ready to Close Contact
= Total 2. = Total 4. Non-Auto Trip Indication Switch-Gold (Not Ready to Close) Non-Auto Spring Charge Switch-Gold Open/Close Cycle Counter
**Split Circuit - Voltages for the motor and closing coil must be indicated below.
AC110 AC120 AC200 AC220 AC230 AC240 AC380 ----AC400 ----AC415 ----AC440 -----
---------------------------------
-----------------
See page 2 of 2 for External Accessories, Locking/Interlocking Systems and Earthing devices.
page 116
(Please photocopy)
PAGE 2 OF 2
AWR-1B AWR-2B
Right mm
P=
mm
(Please photocopy)
page 117
page 118
page 119
PFC
ECCTT.40125* ECCTT.40150* ECCT.40125 ECCT.40150 ECCT.40225 ECCT.40250 ECCT.40325 ECCT.40425 ECCT.41125 ECCT.41150 ECCT.41225 ECCT.41425 ECCT.41325 ECCT.41425 ECCT.44130 ECCT.44160 ECCT.44230 ECCT.44260 ECCT.44330 ECCT.44430 ECCT.48125 ECCT.48150 ECCT.48225
ECCTX.40125 ECCTX.40150 ECCTX.40225 ECCTX.40250 ECCTX.40325 ECCTX.40425 ECCTX.41125 ECCTX.41150 ECCTX.41225 ECCTX.41425 ECCTX.41325 ECCTX.41425 ECCTX.44130 ECCTX.44160 ECCTX.44230 ECCTX.44260 ECCTX.44330 ECCTX.44430 ECCTX.48125 ECCTX.48150 ECCTX.48225 ECCTX.48250 ECCTX.48325 ECCTX.48425 ECCTX.55130 ECCTX.55160 ECCTX.55230 ECCTX.55260 ECCTX.55330 ECCTX.55430 ECCTX.40112 ECCTX.40212 ECCTX.40125 ECCTX.40150
25 50 25 50 50 100 75 100 25 50 50 100 75 100 30 60 60 120 90 120 25 50 50 100 75 100 30 60 60 120 90 120 12.5 25 25 50
400 400 400 400 400 400 400 400 415 415 415 415 415 415 440 440 440 440 440 440 480 480 480 480 480 480 550 550 550 550 550 550 400 400 400 400
36.1 72.2 36.1 72.2 72.2 144.3 108.3 144.3 34.82 69.64 69.64 139.28 104.45 139.28 39.4 78.8 78.8 157.5 118.1 157.5 30.1 60.2 60.2 120.4 90.3 120.4 31.5 63.0 63.0 126.1 94.5 126.1 18.1 36.1 36.1 72.2
1x25 1x50 1x25 1x50 2x25 2x50 3x25 4x25 1x25 1x50 2x25 4x25 3x25 4x25 1x30 1x60 2x30 2x60 3x30 4x30 1x25 1x50 2x25 2x50 3x25 4x25 1x30 1x60 2x30 2x60 3x30 4x30 1x12.5 2x12.5 1x25 1x50
150 150 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480
250 250 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 345 545 545 545 545
400 400 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 365 315 315 315 315
PFC
ECCT.48250 ECCT.48325 ECCT.48425 ECCT.55130 ECCT.55160 ECCT.55230 ECCT.55260 ECCT.55330 ECCT.55430 ECCT.40112 ECCT40212 ECCT.40125 ECCT.40150
Control Regulators
Automatic power factor correction regulator with microprocessor management for 6-8-12 steps activation with THD1% control, temperature control and serial connector only for 8-12 steps version. The unit is designed to check very distorted signals and be able to ensure an accurate control of plan electrical values like voltage, current, power factor, internal temperature of the equipment (EPF8T-EPF12T) voltage harmonic distortion (EPF8T-EPF12T).
Standard Version (6 Stage) Features: Advanced Version (8,12 Stage) Features:
Full Auto/Manual Setting Automatic CT Polarity Check Display: PF, A, V, Icw Alarms: Under/over correction
page 120
Standard Units
Both CT and CTX types are equipped with PRT series capacitors.
Both CTF and CTFX types are equipped with PRT series capacitors.
PFC
CT TYPE CTX TYPE
Note: Refer to Technical Data on page 13 for dimensions.
page 121
PFC
Control Regulators
Code ECEPF6 ECEPF8T ECEPF12T Description 6 Stage PFC Control Relay 8 Stage PFC Control Relay 12 Stage PFC Control Relay Stages Kvar 6 8 12 Price
page 122
For further information please see the specic catalogues. These catalogues give full technical and dimension data.
page 123
PFC
ECERA14012 ECERA14015 ECERA14017 ECERA14020 ECERA24022 ECERA24025 ECERA24027 ECERA24030 ECERA34032 ECERA34035 ECERA34040
125Kvar 400V 50Hz Equipment 150Kvar 400V 50Hz Equipment 175Kvar 400V 50Hz Equipment 200Kvar 400V 50Hz Equipment 225Kvar 400V 50Hz Equipment 250Kvar 400V 50Hz Equipment 275Kvar 400V 50Hz Equipment 300Kvar 400V 50Hz Equipment 325Kvar 400V 50Hz Equipment 350Kvar 400V 50Hz Equipment 400Kvar 400V 50Hz Equipment
4 4 5 5 6 7 7 8 8 9 10
125 150 175 200 225 250 275 300 325 350 400
PFC
page 124
20Kvar 400V 50Hz Equipment 25Kvar 400V 50Hz Equipment 30Kvar 400V 50Hz Equipment 35Kvar 400V 50Hz Equipment 40Kvar 400V 50Hz Equipment 50Kvar 400V 50Hz Equipment 60Kvar 400V 50Hz Equipment 70Kvar 400V 50Hz Equipment
1 1 1 1 1 1 1 1
20 25 30 35 40 50 60 70
Automatic Version
Code Description Stage Kvar 2.5/5 2.5/5 2.5/5/10 5/10 5/10 5/10 5/10/20 10/20 Stages Total Price
7.5Kvar 400V 50Hz Equipment 12.5Kvar 400V 50Hz Equipment 17.5Kvar 400V 50Hz Equipment 20Kvar 400V 50Hz Equipment 25Kvar 400V 50Hz Equipment 30Kvar 400V 50Hz Equipment 35Kvar 400V 50Hz Equipment 50Kvar 400V 50Hz Equipment
2 5 3 3 3 4 3 3
7.5
17.5 20 25 30 35 50
60Kvar 400V 50Hz Equipment 70Kvar 400V 50Hz Equipment 80Kvar 400V 50Hz Equipment 100Kvar 400V 50Hz Equipment 125Kvar 400V 50Hz Equipment 150Kvar 400V 50Hz Equipment 175Kvar 400V 50Hz Equipment
4 4 4 5 5 6 7
page 125
PFC
12.5
page 126
page 127
TEMPROTECT
ELRC-1
The ELRC-1 Earth Leakage Relay is manufactured with a built-in Toroidal Transformer. It is especially suitable for those applications where space savings is an advantage (for example Motor Control Centres, Battery Distribution Centres etc.) The ELRC-1 is an extremely compact, user friendly unit that offers excellent Adjustable tripping current and time delaysettings Selectable automatic or manual reset facility Adjustable time/current multiplier settings Test button LEDs to indicate the units status
TEMPROTECT
Trip sensitivity range standard 25mA-25A. Time delay range 0.02 to 5 seconds.
ELR-3C
The ELR3-C Earth Leakage Relay has the same excellent functionality as the larger DIN 96x96mm ELR-1E model with reduced dimensions. The ELR3-C is a din rail mounted unit (DIN 43880 Standard) the three modules width (17.5mm). Trip sensitivity range standard 25mA-25A, with an external multiplier (x100 250mA- 250A. Time delay range of 0.02 to 5 seconds.
TCS
The TCS Supervision Relay is a devoted trip circuit supervision relay that monitors the protection devices (circuit breaker) tripping circuit. The TCS relay provides the user with peace of mind especially in critical applications such as safety or emergency circuits or where a circuit breaker failure may result in the loss of supply.
page 128
Code 601110003
Price
Multiplying CT
Code 601210000 Description CT1M-External Multiplier (x10 sensitivity) Price
page 129
TEMPROTECT
Mounting Accessories
Code Description ELRC-1 COVER 100mm ELR IP54 COVER Price
TEMPROTECT
631501000 631501054
page 130
page 131
page 132
page 133
TEMMEASURE
TEMA-90H ANALYSER
The TEMM-90H has the same functionality as the TEMM-90, with the addition of a harmonic analysis function up to the 31st harmonic.
TEMMEASURE
NRG SOFTWARE
NRG is supervision and control software for managing electrical networks from a PC. The software gathers data generated from TEMM multifunction meters and TEMA multifunction analysers and displays the information in a clear easy-to-understand format. The software is very intuitive and simple to use.
page 134
TEMM-R4-HP The TEMM-R4-HP is ush mounted DIN 96x96mm with a shallow depth (56mm including terminals). It is an easy-to-use digital multifunction energy meter.
Auxiliary Supply: Self powered Protection Degree: Front IP52 Box IP 20 Measured Parameters: VL-L, VL-N, A, cos phi, P. F., F, oT, W, VAr, VA, kWh, kVArh, kVAh Measuring Accuracy: Voltage: <0.5%, Current: <0.5%, Powers: <1% Energies: <1% Communications: Pulsed output
TEMM-R4-485 The TEMM-R4-485 is a ush mounted DIN 96x96mm with a shallow depth (56mm including terminals). It is an easy to use digital maltifunction energy meter with an RS485 communication output.
Auxiliary Supply: Self powered Front IP52 Box IP 20 Protection Degree: Measured Parameters: VL-L, VL-N A, cos phi, P. F., F, oT, W, VAr, VA, kWh, kVArh, kVAh Measuring Accuracy: Voltage: <0.5%, Current: <0.5%, Powers: <1% Energies: <1% Communications: MODBUS-RTU, baud rate 9600-19200 bps.
page 135
TEMMEASURE
Price
NRG Software
Code 631300002 631300004 631300008 631300016 631300032 Description NRG 2 Software NRG 4 Software NRG 8 Software NRG 16 Software NRG 32 Software NRG 64 Software NRG 128 Software Price
TEMMEASURE
631300064 631300028
page 136
page 137
TERASAKI ORGANISATION TERMS AND CONDITIONS OF SALE TEE1006 1. INTERPRETATION For the purposes of these terms and conditions of sale the following terms shall have the meaning ascribed to them by this Clause except where this would be inconsistent with the context in which they occur. Company means Terasaki Electric (Europe) Limited incorporated under the Companies Acts and having a place of business at Eighty Beardmore Way Clydebank Industrial Estate Clydebank and any other member of the Terasaki Group of Companies from time to time. Purchaser means any individual or individuals or incorporated or unincorporate body ordering or purchasing Goods and/or Services (as hereinafter defined) from the Company. Goods means the articles and Services means the services which are ordered and/or purchased by the Purchaser from the Company. Contract means a contract made between the Company and the Purchaser for the supply of Goods and/or Services to the Purchaser. Terms and Conditions means terms and conditions for the sale of Goods and/or Services as specified in this document and as adjusted from time to time. 2. GENERAL The Terms and Conditions shall apply to every Contract unless the Company agrees otherwise in writing. 3. CONDITIONS OF CONTRACT Where a Contract is concluded, in the event of any conflict between the Terms and Conditions and the terms of any offer made by a Purchaser to purchase Goods and/or Services the Terms and Conditions shall override and prevail over the terms of any such offer. 4. VALIDITY Any tender submitted by the Company is an invitation to transact business and not an order. The placing of an order by the Purchaser whether in accordance with the terms of a tender or otherwise constitutes an offer by the Purchaser and a Contract shall only be concluded if such an offer is accepted in writing by the Company. 5. PRICE & VAT All prices quoted are subject to the addition of VAT when chargeable at the rate prevailing at the appropriate tax point. The Company reserves the right to make an extra charge for packing cases where these are required for non-catalogue items although this will be returnable where appropriate. Confirmation of price is necessary at time of order. The Company reserves the right to adjust prices quoted in its price list without notice. 5.1 The minimum order value is 50 excluding VAT. 6. OBLIGATIONS OF PURCHASER Any order must be accompanied by sufficient information to enable the Company (if it accepts the same) to proceed with the order forthwith. If any delay in manufacture or delivery should take place due or partly due to the Purchasers failure to provide such information or otherwise due to any sort of delay or change on the part of the Purchaser the Company shall in addition to its other rights in respect therefore be at liberty to make an additional charge in respect of increased costs. Any sample supplied by the Company will be on a sale or return invoice. If sample Goods are not returned within a maximum of Three months the Companys original invoice will be valid and due for payment. 7. DRAWINGS ETC. All descriptive and item specifications drawings or weights and dimensions which may be submitted uncertified with any tender are approximate only. Any description or illustration contained in the Companys catalogues, price lists or other sales or promotional matter is intended merely to convey a general idea of the Goods and/or Services described; it is not intended to amount to any representation or warranty and shall not form part of any Contract. 8. INSPECTION AND TEST The Companys products are carefully inspected and where practical submitted to a suitable test (which may be of a sample) at the Companys works before despatch. If tests other than those specified in the Companys tender or tests are required in the presence of the Purchaser or its representatives these will be carried out at the Purchasers expense. In these circumstances the Purchaser or its representatives will be given 5 working days notice that the Company is ready to carry out such tests and thereafter the tests will proceed irrespective of whether the Purchaser or its representatives attend and they shall be deemed to have attended. 9. PERFORMANCE AND SUITABILITY The Company accepts no liability for failure of Goods to achieve performance figures quoted unless they are specifically guaranteed in writing by a duly authorised officer of the Company subject to the recognised tolerances and rejection limits applicable to such figures. The Company is to be given reasonable time and opportunity after delivery to comply with the terms of any such guarantee. The Purchaser assumes responsibility for specifying the correct capacity and performance of the Goods suitable for their purpose. Should the Purchaser consider that any Goods do not conform to Contract the Purchaser must notify the Company in writing within 5 days of the receipt of such Goods, failing which the Goods shall be deemed to conform to Contract. 10. DELIVERY TIME The times estimated for despatch are to be treated as estimates only and will date from the Companys acceptance of the Purchasers offer or if later the date when all necessary information is available to enable the Company to process the order. The Company shall use its best endeavours to despatch by the date estimated but will have no responsibility for failure. It shall be a reasonable cause for the delay in despatch of the order if the Company shall suffer from or be affected by strikes, lock outs or anything beyond the control of the Company. 11. DESPATCH Orders worth less than five hundred pounds (500) sterling will be supplied by the Company ex-works Glasgow. Orders worth five hundred pounds (500) sterling and over will be supplied F .O.R. the Purchasers works. Unless otherwise agreed delivery method will be at the Companys option. The Company may charge the Purchaser for any special delivery requested. 12. LOSS OR DAMAGE IN TRANSIT The Company does not accept any responsibility for damage, shortage or loss in transit unless (a) the Company and the carriers are notified in writing of such damage, shortage or loss within such time as will enable the Company to comply with the carriers conditions of carriage as affecting damage, shortage or loss in transit and (b) when the goods have not arrived the Company and carriers are notified within 5 working days of the date of despatch. Where delivery is made by the Companys transport the Company must be notified in writing of any damage, shortage or loss within 3 working days of receipt of the goods. Subject to the above conditions being met the Company will replace or repair free of charge goods lost or damaged in transit.
13. WARRANTY 13.1 The Company accepts responsibility for the repair or replacement of any Goods which are defective where such defects arise solely or mainly from faulty materials and/or workmanship provided that the Purchaser complies with the following namely: (a) that written notification giving full particulars of such defects are received by the Company within 1 month of such defect becoming apparent and in any event within 1 year of delivery to the Purchaser (b) any goods which the Purchaser may claim to reject shall be returned to the Company within 10 working days after such notification for inspection by the Company and repair or replacement as the Company reasonably deems necessary. For the purpose of such clauses (a) and (b) hereof time shall be deemed to be of the essence. 13.2 This guarantee is given in place of all warranties, conditions, statements and liabilities whatsoever implied by common law, statute, trade usage or otherwise all of which shall accordingly be excluded. Furthermore the Company and its servants and agents shall not be liable for any injury or loss or damage whatsoever whether direct, consequential or special and howsoever caused resulting from or arising out of or incidental to (a) the Companys performance or failure to conform to any obligations under any Contract or (b) any defect in the goods or (c) any advice or services supplied by the Company or on its behalf in relation to the assembly, installation or use of goods. 14. TERMS OF PAYMENT Unless otherwise agreed in writing payment in full shall be due within 30 days of the date of the invoice. Invoices are raised on dispatch of goods. Interest will be payable from the due date of payment at a rate of 2% per month or part thereof on any part of the purchase price remaining unpaid after due date. 15. CANCELLATION OF ORDERS The Purchaser shall not be entitled to cancel any order accepted by the Company without the Companys written consent and without payment of any cancellation charges determined by the Company. 16. SUSPENSION OR CANCELLATION OF DELIVERIES AND LIEN If the Purchaser: (a) fails to pay any sum due to the Company under any Contract or otherwise by the due date; or (b) otherwise defaults in or commits a breach of any Contract or any other obligation due to the Company; or (c) shall be apparently insolvent or being a company shall enter into liquidation whether compulsory or voluntary (except for the purposes of reconstruction or amalgamation) or if a Receiver of all or part of the Purchasers undertaking shall be appointed; or (d) enters into an arrangement with its creditors or suffers any diligence to be done or execution to be levied on its goods then and in any such event and without prejudice to its whole rights and remedies the Company shall be entitled to terminate wholly or in part any or every Contract between the Company and the Purchaser. The Company shall be entitled to exercise a general lien on all goods belonging to the Purchaser in the Companys possession in respect of sums due to the Company whether or not such goods have been paid for. 17. DISPUTES AND SET-OFF The Purchaser shall make payment to the Company under each and every Contract in accordance with the Terms and Conditions and shall not exercise or seek to exercise any right or claim to withhold payment or any right of compensation or set-off in respect of any alleged breach of any Contract by the Company. 18. PASSING OF PROPERTY The risk in the Goods shall pass to the Purchaser on delivery and the Purchaser is recommended to take out insurance cover. 19. RETENTION OF TITLE Until full and final payment has been received by the Company under every Contract ownership of all Goods shall remain with the Company and: 19.1. Where full and final payment has not been made as aforesaid and any Goods are disposed of by the Purchaser other than in good faith and for value ownership in all such goods shall remain with the Company. 19.2. Where any Goods are sold at a fair and reasonable price by the Purchaser or are lost or destroyed by the Purchaser and payment has not been made aforesaid the Purchaser shall be deemed to be holding any monies received from such sale or as a result of such destruction on behalf of and as an agent for the Company and shall remit such sums to the Company on demand as required. 19.3. Where Goods have been incorporated in other items by way of the fitting or manufacturing process but remain readily identifiable and shall allow the Company to repossess same at any time without prior notice being given. 20. STORAGE The Purchaser shall be bound to store all goods belonging to the Company in terms hereof in such a way as to be readily identifiable and shall allow the Company to repossess same at any time without prior notice being given. 21. PURCHASERS WARRANTIES The Purchaser shall hold the Company harmless against any loss, damage or expense resulting from an infringement of patents or trademarks arising from compliance by the Company with the Purchasers design specifications or instructions. 22. ARBITRATION If any question, dispute or difference whatsoever shall arise between the Company and the Purchaser in relation to any Contract or the interpretation of these conditions at the sole option of the Company the same shall be submitted for arbitration to a person to be mutually chosen and failing agreement by the President for the time being of the Institute of Electrical Engineers. 23. WAIVERS The rights of the Company in terms hereof shall not be affected by any waiver or forbearance on the part of the Company. 24. HEALTH & SAFETY It is essential that the Goods supplied by the Company are used and installed in accordance with the specifications of the Company and in compliance with the recognised standards of the Electrical Industry and that installation and maintenance be carried out by suitably trained and qualified operatives and the Purchaser accepts responsibility for compliance with these conditions. 25. HEADINGS The headings contained herein are for information and do not form part of these conditions. 26. CHOICE OF LAW The construction of the Terms and Conditions and the validity and performance of every Contract shall be governed by the Law of Scotland and insofar as not already subject thereto the Company and the Purchaser submit to the non-exclusive jurisdiction of the Court of Session or the Sheriff Court of the appropriate Sheriffdom. 27. DATA PROTECTION ACT The Company will make a search with a credit reference agency, which will keep a record of that search and will share that information with other businesses. It may also make enquiries about the principal directors with a credit reference agency.
page 138
page 139
To order technical catalogues for any of the products included in this price list contact:
marlene.stirling@teraskaki.co.uk t. 0141 941 1940 f. 0141 952 9246 or download them from: www.terasaki.com Place an order: sales@terasaki.co.uk t. 0141 941 1940 f. 0141 941 9246 Terasaki Electric (Europe) Ltd 80 Beardmore Way, Clydebank Industrial Estate, Glasgow, G81 4HT. UK. Ratings, specifications and prices published in this document may be subject to change without notice. Confirm that they meet your requirements before placing an order. Publication reference: PL0809. 1st August 2009.