Multiroller Presentation
Multiroller Presentation
Multiroller Presentation
MULTI ROLLER EX
Product Reference
Hitachi Industrial Equipment Systems Co., Ltd.
Air Compressor Systems Business Division
17 February 2006 1
Concept
Conventional model in Japan:
Higher Function, Advanced Extensibility, 3 types of unit-controller
Improved User-Friendliness (STEPROLLER II in global market)
MULTI ROLLER EX
(hereinafter called “MEX”)
2
Details of Concept
New Multi-Unit Control Method
-Effective energy-saving: Capacity control method is changed from full-speed to I-type
-Advanced extensibility: Each unit is connected by RS486 cable for future extension
-Improved user-friendliness: Touch panel with interactive type 5.7 inch color LCD screen
-Sophisticated function: Pressure predictive control, PID control (2-loop method) exclusively
for V-type, Second pressure setting, Weekly timer, PE connection
(Future option: Remote monitoring by PC)
Unit Details
-Model: Hitachi air compressor (OSP, DSP)
[Confirmation required for non-Hitachi constant speed model compressors]
-Combined with V-type unit (Single-V, Multi-V)
-Unit construction:Master (PCB main body) + Slave (each unit)
-External connection: Easy remote control, Flow indication (option)
Model
MULTI ROLLER EX
“EX” stands for “Expansion”
4
Standard Specification
MR26-4E MR26-8E MR26-12E
5
System Construction (1)
-Connect point connection (input, output) between compressor and MEX
The panel
control enables
to cancel
function and
change setting
8
Function 2: Advanced 2-Loop Control
Control 2 loops: Constant speed loop and V-type loop
Various combinations available:
Constant speed + V-type, Single-V: Loop 1 and Loop2
Multi-V: Loop2 (Can equalize operating hours and speed for V-type )
Loop 1 Loop 2
Control constant speed unit e.g. : Multi-V control
*Turn back control is only available by Loop 1 * Loop 2 is exclusive for V-type control
9
Function 3: Weekly Timer and 2nd Pressure Setting
Built-in Weekly Timer -Sets weekly scheduled operation by multi-unit control
10
Function 4: PID Control
PID control function exclusive for V-type
-MEX performs PID control directly to V-type compressors(variable speed control).
-MEX gives all controlling commands which enables various combination with
constant speed units.
-Easy to change target pressure setting by MEX touch panel.
Frequency
MULTI ROLLER EX command is
added
11
Function 5: Pressure Predictive Control
Pressure Predictive Control (*Patented)
-The peak point is predicted by pressure drop slope calculation.
Enables earlier start-up timing and also prevents pressure drop.
Pressure →
Discharge
Pressure →
Pressure Pressure
Δt
ΔP
Lower limit Prevents press. drop
Lower limit
press.
press.
* Pressure predictive control is only valid for constant speed unit combination.
12
Function 6: Dryer and Pump Control
Auxiliary Equipment Control
Compressor
Air
Air Dryer Receiver
Run・Stop
(AC200V)
Compressor
Operation Answer
・Failure (DC24V)
Air Dryer
13
Function 7: Others
IPI-Blackout Auto Restart Function
-IPI between 20ms to 350ms [AC200V]
→The operating unit judges as abnormal stop and starts up the stopped unit and
continue auto operation
-IPI longer than 350ms [AC200V]
→Selectable to restart auto operation or not
-Can be combined with built-in IPI auto restart function compressor
Solo Operation
-Switchable Auto/Solo operation
HISCREW: Constant speed unit for modulation control,
V-type for variable speed control + On-Off line control
DSP: Constant speed unit for modulation control,
V-type for variable speed control + On-Off line control
(Motor On-Off control is available for DSP.)
Remote Monitoring System (Optional – to be released soon)
-Efficient maintenance by PC remote monitoring function
Install specific software into PC side and change the master PCB for
communication.
14
Remote Monitoring Function (Optional) (Available soon)
Screen Examples
Operation Control Constant
Menu Monitoring Number Pressure Trend
15
Energy-Saving
Improved control method 1 Multi-unit control
(modulation control)
(inc. V-type)
2 400
New multi-unit control
(On-Off line control)
3 300
Parallel operation
Power consumption
by conventional
suction valve
control 200
(%)
100
[Others]
-Consult with your nearest Hitachi distributors for non-Hitachi compressors.
17
Precautions on System
[Electricity]
-Combination with DSP V-type
Power system must be the same as compressor.
(Both must be set to OFF when IPI occurs)
18