Mat Boundary Spring Generator: Input Data & Design Summary

This document provides an analysis of the mat foundation for a structure with the following parameters: - Foundation length of 55 feet and width of 31 feet - Grid tributary area of 1 square foot - Modulus of subgrade reaction (K1) of 100 pounds per cubic inch It then calculates the inside, edge, and corner spring values for the mat foundation based on these input parameters and dimensions. Finally, it provides a table of typical modulus of subgrade reaction values for different soil types and moisture contents.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views

Mat Boundary Spring Generator: Input Data & Design Summary

This document provides an analysis of the mat foundation for a structure with the following parameters: - Foundation length of 55 feet and width of 31 feet - Grid tributary area of 1 square foot - Modulus of subgrade reaction (K1) of 100 pounds per cubic inch It then calculates the inside, edge, and corner spring values for the mat foundation based on these input parameters and dimensions. Finally, it provides a table of typical modulus of subgrade reaction values for different soil types and moisture contents.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Mat Boundary Spring Generator

INPUT DATA & DESIGN SUMMARY


FOUNDATION LENGTH L = 55 ft
FOUNDATION WIDTH B = 31 ft
GRID TRIBUTARY AREA A = 1 ft2
MODULUS OF SUBGRADE K 1
= 100 lb / in3
(Obtained from the soil report for 1' x 1' sf plate load test,
in the absence of a soil report obtain from table below )

INSIDE SPRING VALUE 4.8 kips / inch, at each joint


EDGE SPRING VALUE 2.4 kips / inch, at each joint
CORNER SPRING VALUE 1.2 kips / inch, at each joint

ANALYSIS

k11 ( for B = L )
k s=  = 33.5 lb / in3
k12 ( for B < L )

2
 B+1 
k 11= k 1  = 26.6 lb / in3 = 46 k / ft3
 2B 

 0.5L 
+1 
 B+1   B
2

k 12 = k1    = 33.5 lb / in3 = 58 k / ft3


 2B   1.5 
 

TYPICAL VALUES OF MODULUS OF SUBGRADE REACTIONS, K1 (lb / in3 )


MOISTURE CONTENT
TYPE OF MATERIAL 1 to 4% 5 to 8% 9 to 12% 13 to 16% 17 to 20% 21 to 24% 25 to 28% > 28%

Silts and clays (liquid limit >50) - 175 150 125 100 75 50 25
(OH, CH, MH )

Silts and clays (liquid limit <50) - 200 175 150 125 100 75 50
(OL, CL, ML )

Silty and clay sands 300 250 225 200 150 - - -


(SM & SH )

Gravelly sands Over 300 300 250 - - - - -


(SW & SP )

Silty and clayey gravels Over 300 Over 300 300 - - - - -


(GM & GC )

Gravel and sand Over 300 Over 300 - - - - - -