Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

NKV-330 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Ventilator System

Nihon Kohden ventilators represent the future of patient care

Improving patient safety, quality of care and outcomes,


while also managing costs are critical goals in today's
acute care environment. Medical devices making a positive
contribution towards these goals will be crucial to the
health care of the future.

—What attributes should a NPPV


 ventilator of the future have?—

Solutions for better outcomes


Reliable ventilation preventing life-threatening events

Improving Patient Care


Critical information, intuitive interface, increased patient comfort

Flexibility
From ER to Recovery, Invasive to O2 therapy

Manage Patient Safety


Easily viewable alarms, "hot-swap" battery, HEPA filter

The Nihon Kohden NKV-330 does all this and more, and is
your solution for mechanical ventilation management.
Solution for a better outcomes

Safe, reliable respiratory management

Multiple ventilation modes to address a


variety of clinical environments
Availability of multiple non-invasive ventilation modes as well as a high flow
oxygen therapy mode allows the NKV-330 to operate in various clinical settings
including the ER, intensive care, and intra-hospital transport.

de
n mo
ti o
e n t il a SPONT-PS
V
spontaneous ventilation with pressure support

S/T
spontaneous with timed backup

PCV
pressure control ventilation

PRVC
An pressure regulated volume control
ox
yg
en
the
ra p
ym
od
e

O 2 Therapy
high flow oxygen therapy
Smart Cable system – unique modular connection technology
Using a Smart Cable connecting to a MULTI socket, the NKV-330 automatically detects the parameter (CO2/
SpO2) and starts measuring, which is reflected in the layout of display items on the screen. Realtime monitoring
helps to prevent life-threatening events.

Connecting Recognize

CO2
SpO2

Continuous CO2 and SpO2 monitoring


CO2 and SpO2 monitoring are available, even when the ventilator is in Standby mode.

Nihon Kohden's unique technologies contribute to increasing patient safety

Reliable even under high humidity conditions.


Safe heaterless system prevents burn injuries.

Reliable SpO2 probes from the company that


invented SpO2.
Improving patient Quality of Life

Efficient, quality care

Critical information at your fingertips


The NKV-330 can store up to 72 hours of full-disclosure waveforms, alarm and operation logs, and patient
measurements, allowing the physician to review critical clinical data to determine the best treatment protocol.

Intuitive interface gives you more time for your patients


The sleek, attractive design includes a 12.1 inch color touch screen and operation knob that facilitates
respiratory setting changes while still displaying current waveforms.

KNV330VentilatorCatalog_En_190227.indd 7 2019/10/10 13:46


Increase patient comfort

Formfitting NPPV mask


The Nihon Kohden NPPV mask is designed to fit any facial shape with minimal patient discomfort and skin damage.

Adjust the attachment position using


the support arm of the mask cushion
to fit the mask to patient’s face.

Support arm

Continuous CO2 monitoring during NPPV therapy


The combination of cap-ONE, Nihon Kohden's new class of ultra-compact CO2
sensor, and dedicated NPPV mask optimizes the ability to monitor and detect
changes in the patient's condition, improving patient care and outcomes. This is
particularly useful for measuring carbon dioxide (CO2) during NPPV therapy.

Oxygen flow
from ventilator
CO 2 flow
A flexible ventilator for the dynamic

Mechanical ventilation for the


entire spectrum of respiratory care

Transport

ER

One action to detach the


NKV-330 from the cart.
hospital environment

Recovery
Rehab
ICU

Flexibility to cope with changing patient conditions


Managing Patient Safety

System alerts and redundancy


ensure patient safety

Easily viewable ventilator alarms Ensure continuous operations


A clearly visible alarm indicator on the top of the 12.1 Equipped with both a "hot swap" main battery and an
inch display combined with audible alerts provides internal backup battery, caregivers can be confident
caregivers prompt notification of critical ventilator that should a loss of AC power occur, the NKV-330's
events. operation will continue uninterrupted.

Red

Dual filter protection


Yellow
The NKV-330 incorporates dual HEPA filtration. Air
going to the internal blower first passes through a dust
filter, then through a HEPA filter, prior to reaching the
blower. Air going to the patient passes through an
Cyan additional HEPA filter which is located internal to the
Gas Outlet Connection.

HEPA filter

Prevent missing alarms Dust filter


Breathing
A dual speaker system ensures that an alarm condition circuit filter
will result in an audible alert to the caregiver, even if one
speaker fails.
nOptions

Mount plate DH-330Z Rail hook DH-331Z

Cart, M (H 1000 mm) KC-330Z


Cart, L (H 1100 mm) KC-331Z

Mask for NPPV


NPPV mask NPPV mask with CO2 measurement

NPPV full face mask set cap-ONE mask set


NPPV full face mask set L VM-310Z NPPV cap-ONE mask set L VM-330Z
NPPV full face mask set M VM-311Z NPPV cap-ONE mask set M VM-331Z
NPPV full face mask set S VM-312Z NPPV cap-ONE mask set S VM-332Z

Full face mask cushion L VA-310Z cap-ONE mask cushion L VM-330Z


Disposable Full face mask cushion M VA-311Z cap-ONE mask cushion M VM-331Z
Full face mask cushion S VA-312Z cap-ONE mask cushion S VM-332Z

NPPV mask flame VA-380Z

Reusable

NPPV head gear VA-381Z


This brochure may be revised or replaced by Nihon Kohden at any time without notice.

9842 CAT.No.68-0006A ’19.10. SZ. PDF.

You might also like