End Plate Moment Connection
End Plate Moment Connection
End Plate Moment Connection
4-tension bolt
End Reaction= 47.93 kip 213 kN
End Moment= 221.28 kip-ft 300 KN-m
Beam depth d = 17.32 in 440 mm
Beam web thk. twb= 0.47 in 12 mm
Beam Flenge Width bfb= 11.81 in 300 mm
Beam Flenge thk. tfb = 0.79 in 20 mm
Fy = 50 ksi
Fu= 65 ksi
A. Bolt Design(for tension)
Flange Force Ff= 160.6 kip
four tensioned bolt Bolt Force T= 40.1 kip 4
fy = 36 ksi
fc' = 2.5 ksi
P 4.83 kip 21.51 KN
fp = P/(BxN) fp = 0.0340745
m = 1.2952756
n = 1.7716535
from table or equan : α= 0.325
n' = 3.6436676
take maximum value tp=
tp = 0.0796995 in 2.0243673 mm 6.02
tp = 0.1090115 2.7688914 mm 6.77
tp = 0.2241982 5.6946349 mm 9.69
(4 mm added for weather p
END OF BASE PLATE DESIGN
allowable bearing strength
Fb = 1.25 ksi Fb=0.35f'c when full concrete area coverred
Fb = 0.1362293 ksi Fb=0.35f'c when lessl concrete area coverred
Fb ≥ P/A = 1.75 ksi
(P/0.35f'c)^2 ≤ A1A2 ≤ A1^2
30.503515 642.04988 30.50351
A1 ≥
FLANGE
b= 200 mm
tw = 6 mm
b= 102 mm
WEB
b= 200 mm
tw = 4 mm
b= 280 mm
P= 22.52 kip 100 KN
fv = 2.691 ksi (from analysis)
tw = 0.236 in 6 mm
a= 39.370 in 1000 mm
h= 35.433 in 900 mm
fy= 50 ksi
k= 8.58
Cv = 0.3432
0.52471
Fv = 9.0781 ksi < 0.4Fy = 20 ksi
if
PURLIN DESIGN :
IMPOSED LOAD
Live load, LL = 0.57 KN/m2
Weigth of roof sheeting, WR = 4.5 Kg/m2
Purlin mass per unit length, WLMP = 4.9 Kg/m
Colateral load = 0 KN/m2
WdL = 0.1055 kN/m
WLL = 0.741 kN/m
PURLIN DESIGN OK
DEFLECTION OK
Design of Purlin
PURLIN DESIGN :
Ix = 0.00000644 m4
Iy = 0.00000146 m4
IMPOSED LOAD
Live load, LL = 0.57 KN/m2
Weigth of roof sheeting, WR = 4.5 Kg/m2
Purlin mass per unit length, WLMP = 4.9 Kg/m
Colateral load = 0 KN/m2
Dead load of Purlin 0.3989727
PURLIN DESIGN OK
DEFLECTION OK