Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Power System Stability MCQ 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

POWER SYSTEM STABILITY MCQ 2.

1. The over voltage surges in power systems me be caused by

A. Lightning

B. Resonance

C. Switching

D. All of the above

✔View Answer

D. All of the above

2.Our system stability is least affected by

A. Reactance of generator

B. Input torque
C. Losses

D. Reactants of transmission line

Ans C

3. The domains of power system where directional overcurrent relay is indispensable are

A. In case of parallel feeder protection

B. In case of ring main feeder protection

C. Both A and B

D. None of the above

ANS C

4. The stability of the power system is not affected by

A. Generator reactance

B. Line reactance

C. Excitation of generators

D. Line losses
✔View Answer

✍Your Comments

5. The Power Systems are operated with power angle around

A. 10o

B. 30o

C. 70o

D. 80o

✔View Answer

B. 30o

✍Your Comments
6. Power system stability is defined as

A. That attribute of the system or part of the system which enables it to develop restoring forces
between the elements there of equal or greater than disturbing forces so as to restore a state of
equilibrium between the elements

B. The maximum power flow possible through some particular point in the system when the entire or
part of the system is disturbed

C. Both A and B

D. Neither A or B

✔View Answer

A. That attribute of the system or part of the system which enables it to develop restoring forces
between the elements there of equal or greater than disturbing forces so as to restore a state of
equilibrium between the elements

7. Stability limit of a power system is defined as

A. That attribute of the system or part of the system which enables it to develop restoring forces
between the elements there of equal or greater than disturbing forces so as to restore a state of
equilibrium between the elements
B. The maximum power flow possible through some particular point in the system when the entire or
part of the system is disturbed

C. Both A and B

D. Neither A or B

✔View Answer

B. The maximum power flow possible through some particular point in the system when the entire or
part of the system is disturbed

8. Steady-state stability of a power system is the ability of the power system to

A. Maintain voltage at the rated voltage level

B. Maintain frequency exactly at 50 Hz

C. Maintain a spinning reserve margin at all times

D. Maintain synchronism between machines and on external tie lines


✔View Answer

D. Maintain synchronism between machines and on external tie lines

9. Steady-state stability of a power system is improved by

A. Reducing fault clearing time

B. Using double circuit line instead of single circuit line

C. Single pole switching

D. Decreasing generator inertia

✔View Answer

B. Using double circuit line instead of single circuit line

10. With fault clearing time, the transient stability limit of a power system
A. Increases

B. Decreases

C. First increases then decreases

D. First decreases and then increases

✔View Answer

B. Decreases

11. Transient disturbances are caused by

A. Sudden load changes

B. Switching operations

C. Fault in the power system

D. All of the above


✔View Answer

D. All of the above

12. A 500-MVA synchronous machine has H1 = 4.6 MJ/MVA, and a 1500 MVA machine has H2 = 3.0
MJ/MVA. The two machines operate in parallel in a power station. The equivalent H constant for the
two, relative to a 100 MVA base will be

A.

22 MJ/MVA

B.

45 MJ/MVA

C.

52 MJ/MVA

D.

68 MJ/MVA

Solution: