Generator Set Data Sheet: Fuel Consumption
Generator Set Data Sheet: Fuel Consumption
Generator Set Data Sheet: Fuel Consumption
Frequency: 50
Fuel Type: Diesel
Standby Prime
Fuel consumption kVA (kW) kVA (kW)
Ratings 27.5 (22) 24.8 (19.8)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 0.4 0.7 1.1 1.4 0.3 0.7 1.0 1.3
L/hr 1.63 3.25 4.88 6.50 1.50 3.00 4.50 6.00
Fuel flow
Maximum fuel flow, L/hr 40
Maximum fuel inlet restriction, mm Hg 28.0249
Maximum fuel inlet temperature (°C) 60
Air
Combustion air, m3/min 2.30 2.30
Maximum air cleaner restriction, kPa 4
©2010 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Exhaust Standby rating Prime rating
Exhaust gas flow at set rated load, m3/min N/A N/A
Exhaust gas temperature, °C 660 660
Maximum exhaust back pressure, kPa 3.38
Genset outline
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
©2010 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Alternator data
Feature code Connection1 Temp rise degrees C Duty2 Alternator Voltage
- 3 Phase 163/125C S/P PI144E 380-415V
3 Phase 150/125C S/P PI144F 380-440V
Ratings definitions
Emergency Standby Limited-Time running Prime Power (PRP) Base Load (Continuous)
Power (ESP) Power (LTP): Power (COP)
Applicable for supplying power to Applicable for supplying power to a Applicable for supplying power to Applicable for supplying power
varying electrical load for the constant electrical load for limited varying electrical load for continuously to a constant electrical
duration of power interruption of a hours. Limited Time Running unlimited hours. Prime Power load for unlimited hours.
reliable utility source. Emergency Power (LTP) is in accordance with (PRP) is in accordance with ISO Continuous Power (COP) in
Standby Power (ESP) is in ISO 8528. 8528. Ten percent overload accordance with ISO 8528, ISO
accordance with ISO 8528. Fuel capability is available in 3046, AS 2789, DIN 6271 and BS
Stop power in accordance with ISO accordance with ISO 3046, AS 5514.
3046, AS 2789, DIN 6271 and BS 2789, DIN 6271 and BS 5514.