Schneider Panel Builder - Pricelist - 2020
Schneider Panel Builder - Pricelist - 2020
Schneider Panel Builder - Pricelist - 2020
Panel Builder
With effect from January 27th, 2020
se.com/in
Price List Contents
EasyPact SPS:
Low Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Voltage Draw-out type Circuit breakers and Switch disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Fixed type Circuit breaker and Switch disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Products Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
EasyPact TVS:
EasyPact TVS Power Contactors (3 Pole) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
EasyPact TVS Power Contactors (4 Pole) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
EasyPact TVS Contactor Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
EasyPact TVS Thermal Overload Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
EasyPact TVS Circuit Breaker for Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
TeSys Control Range:
TeSys Control Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
TeSys K Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
TeSys K Power Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
TeSys K Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
TeSys D Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
TeSys D Power Contactors (3 Pole) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
TeSys D Green. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
TeSys D Green Electric Coil Contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TeSys D Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
TeSys F Power Contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
TeSys F - Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
TeSys Special Purpose Contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
TeSys H Ultra ComPact starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
TeSys Protection Range:
TeSys Overload Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
TeSys Electronic Over Current Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Switching TeSys Motor Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
GV4LE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
GV4PE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
and Accessories for GV4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Auxilary Contact Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Controlling Circuit Breakers for Motor Protection Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Linergy:
Products Linergy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
TeSys Switches:
TeSys Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
TeSys Motor Monitoring:
TeSys U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
TeSys T - iMCC Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Starters:
Enclosed Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TE Start & TeSys Motor Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Starters Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Selection Table:
Type 2 Co-ordination charts - TeSys
s¬ &USELESS¬
¬$IRECT
ON
,INE¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . 139
s¬ &USELESS¬
¬$IRECT
ON
,INE¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . 140
s¬ &USELESS¬
¬3TAR¬$ELTA¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . . . . 141
s¬ &USELESS¬
¬3TAR¬$ELTA¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . . . . 142
s¬ &USELESS¬
¬$IRECT
ON
,INE¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . 143
Type 2 Co-ordination charts - EasyPact
s¬ &USE¬BASED¬
¬$IRECT
ON
,INE¬STARTERS¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
s¬ &USE¬BASED¬
¬3TAR¬$ELTA¬STARTERS¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Selection Chart
s¬ &USELESS¬
¬$IRECT
ON
,INE¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . 145
s¬ &USELESS¬
¬3TAR¬$ELTA¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . . . . 146
s¬ &USELESS¬
¬$IRECT
ON
,INE¬STARTERS¬WITH¬CIRCUIT
BREAKER¬¬0RODUCTS . . . . . . . . . . . . . . . . . . . 147
Price List Contents
Phaseo:
Phaseo Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Phaseo Transformers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Altivar:
Altivar Variable Frequency Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Altistart:
Altistart Soft Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Zelio Logic:
Zelio Smart Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Industrial Zelio Plug-in-Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Zelio SSR / Electronic Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Automation Harmony:
Harmony Control & Signalling Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Products Signalling:
Signalling Control Stations & Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Magelis:
Magelis Industrial PC and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Magelis RACK IPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Magelis Basic HMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Vijeo:
Vijeo XD EcoStruxure™ Operator Terminal Expert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Vijeo Designer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
manufactured products for each of the lifecycle phases on all of its products, in compliance
with the ISO 14025 PEP ecopassport program. PEP is especially useful
have been awarded the for monitoring, controlling, saving energy, and/or reducing
Green Premium ecolabel carbon emissions.
se.com/in 7
Product Selector
-Select Schneider products through digital tool
Product selector is an online software tool embedded in Schneider website or in distributor´s website to help selecting the right
product with its accessories. Product Selector aims at providing a fast, secure and smart way of selecting products. It includes
the selection of the basic frame, control unit, accessories and Digital Modules. Compared with the traditional way of filling up
order forms or specifying customer functions, it brings the following benefits:
Easy access: no login, direct access on Schneider's website or on the website of distributor
Reliable: The compatibility between the main product and the accessories is constantly tested
Wide coverage: more than 130 Schneider ranges are available (MasterPact, ComPact, TeSys, Acti 9, Altivar...)
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 8
Introducing Future of Power Distribution
NEW
Stay connected and avoid downtime - The MasterPact MTZ Contribute to a better world - with Green Premium MasterPact
app and EcoStruxure software conveniently bring energy MTZ circuit breakers you can enhance sustabinability.
data, circuit breaker control, and more directly to your
smartphone.
Access new energy-saving capabilities - Acertified Class Keep your electrical system online even in harsh
1 power meter gives you precise power measurements for environments - MasterPact MTZ circuit breakers give you
greater efficiency. proven reliability by going beyond standards.
Customize MicroLogic X control unit anytime - Digital Simplify your switchboard operation - MasterPact MTZ circuit
modules make it easy to upgrade and tailor your system. breakers are adaptable to different systems because of their
digital capabilities.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 9
Introducing ComPact NSX & NSXm with Integrated Earth
Leakage Protection
NEW NEW
The ComPact NSX range is now complemented The ComPactNSXm range is now available with
with a new type of MicroLogic trip unit including a new type of MicroLogic trip which offers
circuit protection, (overload,short circuit,neutral overload, short circuit protection along with
protection) and earth leakage protection earth leakage protection
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 10
ComPact NSXm circuit breakers:
Optimized for your needs
The ComPact NSXm range of circuit breakers and switch disconnectors
is a newcomer in the ComPact NSX family. It is one of the smallest on the
market with innovative features. Built on the design of roto-active
breaking technology, we have made it as robust as ComPact NSX
products.
To experience,
Click or Scan
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 11
ComPact NSXm Moulded Case Circuit Breakers
s¬ )CS¬¬¬)CU¬AS¬PER¬)%#¬
s¬ !DJUSTABLE¬THERMAL¬SETTING¬¬n¬¬X¬)N
s¬ &IXED¬MAGNETIC¬SETTINGS
LUG CONNECTION s¬ 3INGLE¬FRAME¬SIZE¬UPTO¬!
s¬ ¬BREAKING¬CAPACITIES¬FROM¬K!¬TO¬K!
s¬ 7ITH¬COMPRESSION¬LUG¬CONNECTORS
s¬ !LL¬THE¬CIRCUIT¬BREAKERS¬HAVE¬A¬TRANSPARENT¬LEAD
SEALABLE¬COVER
se.com/in 12
ComPact NSXm MCCB with Integrated
Earth Leakage Protection NEW
s¬ 3TANDARD¬PROTECTION¬OF ¬DISTRIBUTION¬CABLES
s¬ %ARTH¬LEAKAGE¬PROTECTION
s¬ )NDICATION¬OF
¬ s¬ /VERLOAD¬ALARMING¬VIA¬,%$S¬AND¬VIA¬3$X¬MODULE
¬ s¬ /VERLOAD¬TRIPPING¬VIA¬THE¬3$X¬MODULE
s¬ %ARTH¬LEAKAGE¬ALARMING¬VIA¬THE¬3$X¬MODULE
s¬ %ARTH¬LEAKAGE¬TRIPPING¬VIA¬FRONT¬FACE¬SCREEN¬AND¬THE¬
SDx module).
For details
Details on
on non-standard
stockable andreferences, technical
non-stockable status,parameters, stockable please
technical parameter, and non-stockable status,Care
Contact Customer please contact Customer Care Centre.
Centre
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 13
ComPact NSXm Switch Disconnector
s¬ 3UITABILITY¬FOR¬ISOLATION¬AS¬DElNED¬BY¬STANDARD¬)%#¬
s¬ 3ELF ¬PROTECTED¬BY¬THEIR¬HIGH
SET¬MAGNETIC¬RELEASE
s¬ 3INGLE¬FRAME¬SIZE¬UPTO¬!
pact
Com
6559 act
LV42 Comp
et
4P frame
559
Res
40°C
LV426
OFF
Cat.A
-2
IEC/EN60947
8kV
Uimp 40°C
50/60Hz Ics(kA) Cat.A
Ui 8kV Icu(kA) 100 IEC/EN60947-2 Uimp
8kV
Ue(V)
100 70 50/60Hz Ics(kA)
240 70 65 Ui 8kV Icu(kA) 100
65 100 70
415 30 Ue(V)
70
240 65
440 30 22 65
415 30
500 22 6 440 30 22
525 10 500 22 6
525 10
690
690
2
GB14048. GB14048.2
AB1 AB1 HIC
NEMA HIC NEMA 100
100 65
65 240 25
240 25 480
600Y/347
Trip
480
600Y/347
Ø 4.
On
..8
Trip
MN Off
Ø 4...8
250V
4P frame
Reset
~/=
t
se
Re
pact
Com
6559
LV42
40°C
Cat.A
47-2 8kV
50/60Hz Uimp
IEC/EN609 Ics(kA)
100
Ui 8kV Icu(kA) 100 70
Ue(V) 240 70 65
415 65 30
440 30 22 On
500 22 6
525 10
Ø 4...8
690
Trip
8.2 AB1 HIC
GB1404 NEMA
100
65
Ø 4.
25
240
480
600Y/347
..8
Trip
Off
Ø 4...8
Reset
Terminal spreaders OF or SD auxiliary MN or MX voltage Direct rotary handle Side Rotary handle Extended rotary handle
contact standard releases standard
NSXm Accessories
Auxiliary contacts (changeover) Voltage Releases
Description Reference Unit LP [`] Shunt Release Under Voltage
Description Unit LP [`] Unit LP [`]
Standard OF or SD LV426950 820 Reference Reference
AC
Rotary Handles 24 V 50/60 Hz LV426841 LV426801
Description Reference Unit LP [`] 48 V 50/60 Hz LV426842 LV426802
Direct rotary handle 110-130 V 50/60 Hz LV426843 2040 LV426803 2650
Standard black handle LV426930 1100 220-240 V 50/60 Hz LV426844 LV426804
Extended rotary handle 380-415 V 50 Hz LV426846 LV426806
Standard extended rotary DC
LV426932 1650 24 V LV426841 LV426801
black handle
Side rotary handle 48 V LV426842 LV426802
2040 2650
Standard side rotary black 125 V LV426843 LV426803
LV426935 2800
handle 250 V LV426844 LV426815
Rotary Handles
Description Reference Unit LP [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV426940 600
Spreaders (Set of 4) 4P LV426941 600
Everlink Accessories
Description Reference Unit LP [`]
Everlink Connectors
EverLink connector with control
LV426970 650
wire terminal for 3P (Set of 3)
EverLink connector with control
LV426971 850
wire terminal for 4P(Set of 4)
se.com/in 14
MCCB for Motor Protection
GV4LE
s¬ )%#%.¬
¬)%#%.¬
¬###¬%!#
s¬ #AN¬BE¬USED¬WITH¬CLASS¬¬¬OR¬¬RELAY
s¬ 3HORT¬#IRCUIT¬0ROTECTION¬WITH¬AN¬ADJUSTABLE¬PICK
UP¬)I¬¬¬TO¬¬)N
s¬ &ROM¬¬
¬K7
GV4PE
tIEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60497-4-1, CCC,
EAC, CSA
tOverload or thermal protection
tShort time delay protection
tShort circuit protection
tFixed Ground fault protection
tPhase unbalance or phase loss
tFront indications through LED
tVariable Trip class : Trip Class 10/ Trip Class 20
For details
Details on
on non-standard
stockable andreferences, technical
non-stockable status,parameters, stockable please
technical parameter, and non-stockable status,Care
Contact Customer please contact Customer Care Centre.
Centre
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 15
Accessories for GV4
MX Shunt Trip
t Trips the circuit breaker when the control voltage rises above 70% of rated
voltage
t Shunt trip 110..130V AC is suitable.. etc for ground fault protection when
combined with a Class I ground fault sensing element
Auxiliary Contact Block 2 (1 Each For Of Or Sd) Internal Plug-In NO+NC GV4AE11 800
Rotary Handles
Description Type Degree of Protection Reference Unit LP [`]
Black IP40 GV4ADN01
Direct Mounting Rotary Handle 1195
Red Handle on Yellow Bezel IP40 GV4ADN02
Black IP54 GV4APN01
Front Extended Rotary Handle (Min Shaft Length 1775
Red Handle on Yellow Bezel IP54 GV4APN02
214Mm/Max Shaft Length 627Mm)
Red Handle on Yellow Bezel IP65 GV4APN04 1865
Side Rotary Handle (Left or Right) Black IP54 LV426935 2800
Connection Accessories
Description Reference Unit LP [`]
Spreader 3-pole (To increase pitch to 35mm) (1 pce) LV426940 600
se.com/in 16
Ethernet Ready Next Generation Circuit Breakers
ComPact NSX
LV circuit breakers from 16A to 630A
se.com/in 17
ComPact NSX
t Ethernet based monitoring, control, alarm notification for energy, asset and network
management
t Built-in energy metering with combined accuracy class of 2% for precise
measurement
t Intelligent / Enhanced discrimination for continuity of service
t Patented reflex tripping, independent of other protection functions, ensures ultra fast
tripping in the event of very high short circuit
t Encapsulated roto-active double break contact system limits fault current for extended
system life
t Best in class electrical life (30k cycles for NSX 100 @ 440 V) reduces operational expenditure
t HIGH¬PERFORMANCE¬¬)CS¬¬)CU¬¬K!¬ ¬6¬!#
Range Details:
t 16A to 630A in two frames sizes
t Breaking capacity up to 200kA @ 415V
t TMD and Electronic based trip unit
t Available in Fixed, Plug-in and Draw out type versions
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 18
Type of Trip Units
Example
MicroLogic 1.3 M I 400 or 630 A Motor
MicroLogic 2.2 G LS0I 100, 160 or 250 A Generator
MicroLogic 2.3 LS0I 400 or 630 A Distribution
MicroLogic 2.3 M LS0I 400 or 630 A Motor
MicroLogic 5.2 A LSI 100, 160 or 250 A Ammeter Distribution
MicroLogic 5.3 E LSI 400 or 630 A Energy Distribution
MicroLogic 6.3 E-M LSIG 400 or 630 A Energy Motor
I - Instantaneous
S0 - Short Time with Fixed Time Delay
S - Short Time with Adjustable Time Delay
G - Ground Fault
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 19
ComPact NSX PV for Photovoltaic applications
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 20
PowerPact
Trust US...
stop
1
to supply worldwide availabilty
to apply tested and validated solutions
to comply to international standards shop
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 21
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
s¬ 4RANSPARENT¬COVER¬FOR¬TRIP¬UNIT¬AS¬STANDARD
s¬ "REAKING¬#APACITY¬ENHANCEMENT¬UPTO¬K!¬WITH¬A¬HIGHER¬CAPACITY¬
upstream (Cascading)
s¬ %XCEPTIONAL¬CURRENT¬LIMITING¬¬¬X¬¬!3
Note:
s¬
¬APPLICABLE¬FOR¬.38¬!¬¬!
s For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 22
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
Note: For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.
Relay Module 3 Ph + 3W 3 Ph + 4W
MCCB Frame Unit LP [`] Unit LP [`]
rated current Reference Reference
CVS/NSX100 32, 40, 50, 63, 80, 100 GFP11CT13P ; 5280 GFP11CT14P ; 5790
CVS/NSX 160 / 250 125, 160, 200, 250 GFP12CT23P ; 6000 GFP12CT24P ; 6780
CVS/NSX 400 / 630 400, 630 GFP13CT33P ; 9070 GFP13CT34P ; 9910
CVS 800 800 GFP14CT43P ; 11190 GFP14CT44P ; 12520
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 23
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
Faulty phase
Interrupted current
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 24
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
Faulty phase
Interrupted current
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 25
ComPact NSX Circuit Breakers for Motor Protection
s¬ ICS¬¬¬)CU¬AS¬PER¬)%#¬
s¬ Adjustable magnetic setting Im 6 -14 x In (2.5 - 100A) & 9 - 14 x In (150 - 200A)
s¬ Type - 2 Co-ordination charts upto 110 kW at 400V
s¬ Breaking Capacity enhancement upto 150kA with a higher capacity upstream
(Cascading)
s¬ Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB
s¬ Rated at 650C as per motor standards
s¬ ICS¬¬¬)CU¬AS¬PER¬)%#¬
s¬ Suitable for Isolation
s¬ ADJUSTABLE¬SHORT¬CIRCUIT¬)SD¬¬¬
¬X¬)N
s¬ Front indication LED (Ready LED)
s¬ Type - 2 Co-ordination charts upto 250 kW at 400V
s¬ Rated at 650C as per motor standards
Note: For higher breaking capacities (100kA and 150kA), contact our nearest Sales office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 26
ComPact NSX Circuit Breakers for Motor Protection
s¬ ICS¬¬¬)CU¬AS¬PER¬)%#¬
s¬ Adjustable overload Ir 0.45 - 1 x In
s¬ Adjustable short circuit Isd 5 - 13 x Ir
s¬ Trip class selection: Class 5, Class 10 & Class 20
s¬ Phase unbalance or Phase Loss
s¬ Type - 2 Co-ordination charts upto 315 kW at 400V
s¬ FRONT¬INDICATION¬,%${S¬2EADY¬¬TEMPERATURE¬RISE¬ALARM
s¬ Breaking Capacity enhancement upto 150kA with a higher capacity upstream
(Cascading)
s¬ Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB
s¬ Rated at 650C as per motor standards
Note:
s For higher breaking capacities (100kA and 150kA), contact our nearest Sales office.
s For arriving at the Reference of the MCCB with MicroLogic 6E-M, please contact our nearest Sales office.
MicroLogic 6 E-M
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 27
ComPact NSX MCCB with Integrated Earth
Leakage Protection NEW
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 28
MCCBs for DC Network Protection
ComPact NSX DC
Range - 16A to 1200A in Two frames sizes with Thermal Magnetic Trip Unit (TMD)
Note:
For 1P / 2P contact customer care
NSX 1200 prices on request
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 29
ComPact NSX Accessories
Indication contacts SDTAM remote SDx remote Voltage Release Motor Mechanism
indication relay indication relay
module module
Unit LP
Description Reference
[`]
Auxiliary contacts (changeover) Multifunction
OF or SD or SDE or SDV 29450 ; 880
OF or SD or SDE or SDV low level 29452 965
SDE adaptor for trip unit TM or MA or MicroLogic 2 $$ LV429451 ; 700
SDX 2-PROGRAMMABLE CONTACTS FOR MICROLOGIC
SDx module 24/415 V AC/DC LV429532 11100
SDTAM contactor tripping module for MicroLogic 2- M/6 E-M
SDTAM 24/415 V AC/DC overload fault indication LV429424 11505
Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 ; LV429406 ;
2250 2930
220-240 V 50/60 Hz LV429387 ; LV429407 ;
380-415 V 50 Hz LV429388 ; LV429408 ;
525 V 50 Hz LV429389 LV429409
DC
12 V LV429382 LV429402
24 V LV429390 ; LV429410 ;
30 V LV429391 LV429411
48 V LV429392 2250 LV429412 2930
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414 ;
Installation Accessories
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Spreaders & Phase Barrier
Spreaders (Set of 3) 3P LV431563 ; 620 32492 ; 1400
Spreaders (Set of 4) 4P LV431564 ; 820 32493 ; 1780
Phase Barrier (Set of 6)
- LV432570 ; 750
Interlocking
For Breaker with Rotary Handle LV429369 8655 LV432621 10895
For Breaker with Toggle LV429354 9465 LV432614 10895
Mechanical Interlocking with Base Plate 2
18560 3
39090
Locking of Rotary Handle
Locking Device LV429344 ; 550 LV432604 ; 750
Ronis Keylock (1 Lock + 1 Key set) 41940 ; 3785 41940 ; 3785
Ronis Keylock (2 Locks + 1 Key set) 41950 ; On request 41950 ; On request
Profalux Keylock (1 Lock + 1 Key set) 42888 6385 42888 6385
Profalux Keylock (2 Locks + 1 Key set) 42878 7290 42878 7290
¬SUPPLIED¬AS¬STANDARD¬WITH¬SPREADER
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 30
ComPact NSX Accessories
FDM121: Front Display Test Battery Power Supply ModuleB SCM: Breaker Status and
Module Control Module
Motor Mechanism
100/160A Unit LP 250A Unit LP 400/630A Unit LP
Type Voltage
Reference [`] Reference [`] Reference [`]
Motor Mechanism Modules with SDE Adaptor (1)
48-60 V LV429440 LV431548 LV432639
110-130 V LV429433 LV431540 LV432640
AC
220-240 V LV429434 ; 20440 LV431541 ; 22590 LV432641 ; 32830
50/60 Hz
380-415 V LV429435 LV431542 LV432642
440-480 V LV429435 LV431542 LV432647
24-30 V LV429436 LV431543 LV432643
48-60 V LV429437 LV431544 LV432644
DC 28105 30475 40275
110-130 V LV429438 LV431545 LV432645
250 V LV429439 LV431546 LV432646
(1) With every Motor Mechanism, please order 1 no. auxiliary contact additionally. For other voltages of motor mechanism please consult Customer Care.
Unit LP
Description Reference
[`]
ULP Display Module
Switchboard front display module FDM121 TRV00121 ; 11620
ULP Wiring Accessories
N38¬CORD¬,¬¬¬M LV434200 2680
N38¬CORD¬,¬¬¬M LV434201 2700
5¬2*2*¬-!,%¬#ORD¬,¬¬M TRV00810 2535
10 Stacking connectors for COM interface TRV00217 3950
ULP Communication Module
IFM MODBUS Interface Module LV434000 9790
BSCM ( Breaker Status and Control Module) LV434205 ; 8500
Power Supply Modules
External power supply module 24 V DC-1 A OVC IV
200-240 V AC LV454444 ; 15480
Pocket battery for MicroLogic NSX100-630 LV434206 16900
Maintenance Module for advanced configuration and testing, contact our nearest Sales office.
U,0¬¬5NIVERSAL¬,OGIC¬0LUG
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 31
ComPact NSX Accessories
Direct Rotary Handle Extended Rotary Handle Plug in Base Draw-Out Chassis Kit
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 32
ComPact NSX Automatic Source Changeover System
BA controller (basic)
s¬Monitoring of “Normal” source & “Automatic” transfer
s¬Circuit breaker status indication on front of controller: ON, OFF & fault trip
s¬Voluntary transfer to “Replacement” source (e.g. energy management commands)
UA controller (advanced)
s¬Monitoring of “normal” source & “Automatic” transfer
s¬Circuit breaker status indication on front of controller: on, off & fault trip
s¬Voluntary transfer to “replacement” source (e.g. energy management commands)
s¬Delayed (adjustable) shutdown of generator set
s¬Load shedding & reconnection of non-priority loads
s¬Transfer to “Replacement” source if one of the phases of the “Normal” phase is
absent
s¬During peak tariff period (energy management commands) forced operation on
“Normal” source if “Replacement” source not operational
With NSX100F - NSX630F 36kA 3P MCCB
Breaker for Breaker for 3P BA Controller Unit MRP 3P UA Controller Unit MRP
Normal Supply Replacement Supply Reference [`] Reference [`]
NSX100F NSX100F LV4A3F100100B4 LV4A3F100100U4
NSX160F NSX100F LV4A3F160100B4 LV4A3F160100U4
NSX160F NSX160F LV4A3F160160B4 LV4A3F160160U4
NSX250F NSX100F LV4A3F250100B4 LV4A3F250100U4
NSX250F NSX160F LV4A3F250160B4 LV4A3F250160U4
NSX250F NSX250F LV4A3F250250B4 LV4A3F250250U4
NSX400F NSX100F L6!&"
L6!&5
On request On request
NSX400F NSX160F L6!&"
L6!&5
On request On request
NSX400F NSX160F L6!&"
L6!&5
Note:
Each reference consists of:
2 MCCBs with Motor mechanism & Standard Trip Units.
4 Auxiliary contacts 2OF + 2SDE
1 Base Plate with IVE unit for mechanical & electrical interlocking
1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size
Control Unit UA or BA
ATS upto 250A are provided with TMD type trip unit & for 400/630A with MicroLogic 2 trip unit as standard.
ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied. Prices available on request.
Above given references with BA/UA controller are suitable for 415VAC control supply.
UA controller with 220/240V AC is not available
Replace suffix “4” by “2” for BA controller with 220/240V AC control supply.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 33
ComPact NSX Automatic Source Changeover System
BA controller (basic)
s¬Monitoring of “Normal” source & “Automatic” transfer
s¬Circuit breaker status indication on front of controller: ON, OFF & fault trip
s¬Voluntary transfer to “Replacement” source (e.g. energy management commands)
UA controller (advanced)
s¬Monitoring of “Normal” source & “Automatic” transfer.
s¬Circuit breaker status indication on front of controller: ON, OFF & fault trip
s¬Voluntary transfer to “Replacement” source (e.g. energy management commands)
s¬Delayed (adjustable) shutdown of generator set.
s¬Load shedding & reconnection of non-priority loads.
s¬Transfer to “Replacement” source if one of the phases of the “Normal” phase is absent
s¬During peak tariff period (energy management commands) forced operation on
“Normal” source if “Replacement” source not operational
On request On request
NSX400N NSX160N L6!."
L6!.5
On request On request
NSX400N NSX160N L6!."
L6!.5
Note:
Each reference consists of:
2 MCCBs with Motor mechanism & Standard Trip Units.
4 Auxiliary contacts 2OF + 2SDE
1 Base Plate with IVE unit for mechanical & electrical interlocking
1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size.
Control Unit UA or BA
ATS upto 250A are provided with TMD type trip unit & for 400/630A with MicroLogic 2 trip unit as standard.
ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied. Prices available on request.
Above given references with BA/UA controller are suitable for 415V AC control supply.
UA controller with 220/240V AC is not available
Replace suffix “4” by “2” for BA controller with 220/240V AC control supply.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 34
ComPact NS
Simply A Step Ahead
Circuit breakers and switch-disconnectors from 800 to 3200A
s¬Category B MCCBs
s¬Ethernet based monitoring, control, alarm notification for energy, asset and network management
s¬Built-in energy metering with combined accuracy class of 2% for improved energy efficiency
Total Discrimination
Breaking Capacity upto 150kA
2 sizes:
from 800 to 3200A
L 150kA
H 70kA
n 50kA
NS630b NS800 NS1000 NS1250 NS1600
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 35
ComPact NS MCCB for Distribution Network
800A onwards, Manual Fixed Type
With MicroLogic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
With MicroLogic 2.0 Manual Fixed
Micrologic 2.0
instantaneous
Isd 4 5
3
2.5 6
2 8
1.5 10
x Ir
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_3P33466D ; INA_4P33469D
50kA 1000 INA_3P33472D INA_4P33475D
1250 INA_3P33478D INA_4P33480D
On request On request
800 INA_3P33467D INA_4P33470D
70kA 1000 INA_3P33473D INA_4P33476D
1250 INA_3P33479D INA_4P33481D
With Extended Rotary Handle
800 INA_3P33466E ; INA_4P33469E ;
50kA 1000 INA_3P33472E ; INA_4P33475E ;
1250 INA_3P33478E ; INA_4P33480E
On request On request
800 INA_3P33467E INA_4P33470E
70kA 1000 INA_3P33473E INA_4P33476E
1250 INA_3P33479E INA_4P33481E
long time
Ir tr alarm
.8 (s) 4
8
.7 .9 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
s¬Communication optional
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_3P96466D INA_4P96469D
50kA 1000 INA_3P96472D INA_4P96475D
1250 INA_3P96478D INA_4P96480D
On request On request
800 INA_3P96467D INA_4P96470D
70kA 1000 INA_3P96473D INA_4P96476D
1250 INA_3P96479D INA_4P96481D
With Extended Rotary Handle
800 INA_3P96466E INA_4P96469E
50kA 1000 INA_3P96472E INA_4P96475E
1250 INA_3P96478E INA_4P96480E
On request On request
800 INA_3P96467E INA_4P96470E
70kA 1000 INA_3P96473E INA_4P96476E
1250 INA_3P96479E INA_4P96481E
Remarks:Trip Unit MicroLogic 6.0.A
## Display shows readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are
stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit MicroLogic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, con-
tact our nearest Sales Office
Functionality of all the above MicroLogic is same as that of MasterPact NT/NW ACB.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 36
ComPact NS MCCB for Distribution Network
above 800A Manual Fixed
With MicroLogic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
With MicroLogic 2.0E Manual Fixed (With Embedded Energy Metering)
s¬ LED overload alarm indicator
Micrologic 2.0 E
MWh
_ _5.678
s¬ Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power
100 %
40 %
(P,Q,S), power factor, power demand, Energy (Ep, Eq, Es)
menu
long time
s¬ Adjustable neutral protection - N, N/2, OFF for 4 Pole MCCBs
s¬ Communication option & M2C programmable contacts
Ir tr alarm
.8 (s) 4
8
.7 .9 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
instantaneous
Isd
3 4 5
2.5 6
2 8
1.5 10
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_8N3PFM2ED1 INA_8N4PFM2ED1
50kA 1000 INA_10N3PFM2ED1 INA_10N4PFM2ED1
1250 INA_12N3PFM2ED1 INA_12N4PFM2ED1
On request On request
800 INA_8H3PFM2ED1 INA_8H4PFM2ED1
70kA 1000 INA_10H3PFM2ED1 INA_10H4PFM2ED1
1250 INA_12H3PFM2ED1 INA_12H4PFM2ED1
With Extended Rotary Handle
800 INA_8N3PFM2EE1 INA_8N4PFM2EE1
50kA 1000 INA_10N3PFM2EE1 INA_10N4PFM2EE1
1250 INA_12N3PFM2EE1 INA_12N4PFM2EE1
On request On request
800 INA_8H3PFM2EE1 INA_8H4PFM2EE1
70kA 1000 INA_10H3PFM2EE1 INA_10H4PFM2EE1
1250 INA_12H3PFM2EE1 INA_12H4PFM2EE1
Micrologic 6.0 A
With MicroLogic 6.0E Manual Fixed (With Embedded Energy Metering)
2100A
s¬LED overload alarm indicator
s¬Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power (P,Q,S),
100 %
long time
.8 tr 8
alarm
s¬Adjustable neutral protection - N, N/2, OFF
s¬With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
s¬Communication optional
s¬Individual fault indication by LED
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_8N3PFM6ED1 INA_8N4PFM6ED1
50kA 1000 INA_10N3PFM6ED1 INA_10N4PFM6ED1
1250 INA_12N3PFM6ED1 INA_12N4PFM6ED1
On request On request
800 INA_8H3PFM6ED1 INA_8H4PFM6ED1
70kA 1000 INA_10H3PFM6ED1 INA_10H4PFM6ED1
1250 INA_12H3PFM6ED1 INA_12H4PFM6ED1
With Extended Rotary Handle
800 INA_8N3PFM6EE1 INA_8N4PFM6EE1
50kA 1000 INA_10N3PFM6EE1 INA_10N4PFM6EE1
1250 INA_12N3PFM6EE1 INA_12N4PFM6EE1
On request On request
800 INA_8H3PFM6EE1 INA_8H4PFM6EE1
70kA 1000 INA_10H3PFM6EE1 INA_10H4PFM6EE1
1250 INA_12H3PFM6EE1 INA_12H4PFM6EE1
Remarks:Trip Unit MicroLogic 6.0E
## Display shows readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit MicroLogic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office
Functionality of all the above MicroLogic is same as that of MasterPact NT/NW ACB.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 37
ComPact NS MCCB for Distribution Network
above 800A Electrical Fixed
With MicroLogic Trip Units ( Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
Micrologic 2.0
instantaneous
Isd 4 5
3
2.5 6
2 8
1.5 10
x Ir
setting
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_3P93280_20 INA_4P93284_20
50kA 1000 INA_3P93290_20 INA_4P93294_20
1250 INA_3P93300_20 INA_4P93304_20
On request On request
800 INA_3P93281_20 INA_4P93285_20
70kA 1000 INA_3P93291_20 INA_4P93295_20
1250 INA_3P93301_20 INA_4P93305_20
For Control Voltage 415V AC
800 INA_3P93280_40 INA_4P93284_40
50kA 1000 INA_3P93290_40 INA_4P93294_40
1250 INA_3P93300_40 INA_4P93304_40
On request On request
800 INA_3P93281_40 INA_4P93285_40
70kA 1000 INA_3P93291_40 INA_4P93295_40
1250 INA_3P93301_40 INA_4P93305_40
Micrologic 6.0 A
With MicroLogic 6.0.A Electrical Fixed
2100A
s¬LED overload alarm indicator
s¬Test Facility
100 %
.6
.7
menu
long time
.8
.9
tr
(s) 4
.95 2
8
12
16
alarm
s¬With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
s¬Zone Selective Interlocking
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
s¬Communication optional
Ig
D E F (s) .4 .4 .3
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_3P96280_20 INA_4P96284_20
50kA 1000 INA_3P96290_20 INA_4P96294_20
1250 INA_3P96300_20 INA_4P96304_20
On request On request
800 INA_3P96281_20 INA_4P96285_20
70kA 1000 INA_3P96291_20 INA_4P96295_20
1250 INA_3P96301_20 INA_4P96305_20
For Control Voltage 415V AC
800 INA_3P96280_40 INA_4P96284_40
50kA 1000 INA_3P96290_40 INA_4P96294_40
1250 INA_3P96300_40 INA_4P96304_40
On request On request
800 INA_3P96281_40 INA_4P96285_40
70kA 1000 INA_3P96291_40 INA_4P96295_40
1250 INA_3P96301_40 INA_4P96305_40
## Display shows Readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit MicroLogic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office
Functionality of all the above MicroLogic is same as that of MasterPact NT/NW ACB.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 38
ComPact NS MCCB for Distribution Network
above 800A Electrical Fixed
With MicroLogic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
Micrologic 2.0 E
With MicroLogic 2.0E Electrical Fixed (With Embedded Energy Metering)
MWh
long time
Ir tr alarm
.8 (s) 4
8
.7 .9 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_8N3PFE2E0120 INA_8N4PFE2E0120
50kA 1000 INA_10N3PFE2E0120 INA_10N4PFE2E0120
1250 INA_12N3PFE2E0120 INA_12N4PFE2E0120
On request On request
800 INA_8H3PFE2E0120 INA_8H4PFE2E0120
70kA 1000 INA_10H3PFE2E0120 INA_10H4PFE2E0120
1250 INA_12H3PFE2E0120 INA_12H4PFE2E0120
For Control Voltage 415V AC
800 INA_8N3PFE2E0140 INA_8N4PFE2E0140
50kA 1000 INA_10N3PFE2E0140 INA_10N4PFE2E0140
1250 INA_12N3PFE2E0140 INA_12N4PFE2E0140
On request On request
800 INA_8H3PFE2E0140 INA_8H4PFE2E0140
70kA 1000 INA_10H3PFE2E0140 INA_10H4PFE2E0140
1250 INA_12H3PFE2E0140 INA_12H4PFE2E0140
Accessories
For ComPact NS800 - 1600A
Shunt Release Undervoltage
Type Voltage Unit LP [`] Reference Unit LP [`]
Reference
Voltage Releases
24 V 33659 33668
AC 48 V 33660 33669
50/60 Hz 110-130 V 33661 ; 33670
220-240 V 33662 ; 33671 ;
380-415 V 33664 On request 33673 ; On request
24 V 33659 33668
DC 48 V 33660 33669
125 V 33661 ; 33670
250 V 33662 ; 33671 ;
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 39
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 40
The easy choice for quality and value
EasyPact CVS
LV circuit breakers from 16A to 800A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; W.E.F. January 27, 2020
Safe
NORMAL STOCK ITEMS
Reliable Simple
se.com/in 41
EasyPact CVS
Easy Choice for Quality and Value
t EasyPact CVS MCCBs upto 630A is the easy choice for all your most common electrical distribution
applications
t Encapsulated double break roto technique ensures outstanding current limiting capability
t High electrical / mechanical endurance for enhanced service life
t Single accessory reference for different functions – on/off, trip and fault trip – improves shop floor efficiency
t Separate electrical fault indication for ease of fault diagnosis
t Suitable for isolation
Range Details:
t BREAKING¬CAPACITY¬K!¬TO¬K!¬)CS¬¬¬)CU
t TMD, MA, Microprocessor trip units (LS0I protection 400 & 630A)
and Microprocessor trip units (LSIG protection 25A to 630A).
t 3P & 4P versions available
t Common accessories upto 630A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 42
EasyPact CVS 100 BS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 BS Overload Setting (Ir) 0.8 - 1 x In
16A LV510930 LV510950
20A LV510931 LV510951
25A LV510932 LV510952
32A LV510933 LV510953
2K!
40A LV510934 6280 LV510954 8530
50A LV510935 LV510955
63A LV510936 LV510956
80A LV510937 LV510957
100A LV510938 LV510958
Accessories
CVS100BS Unit LP
Description
Reference [`]
Auxiliary contacts (changeover) Multifunction
Auxiliary Switch 1 C/O EZAUX10 ; 800
Alarm Switch 1 C/O EZAUX01 800
Alarm - Auxiliary Switch EZAUX11 ; 1190
Spreaders
SPREADERS¬
3ET¬/F ¬ ¬0 EZASPDR3P ; 320
SPREADERS¬
3ET¬/F ¬ ¬0 EZASPDR4P ; 430
Rotary Handle
Direct Rotary handle EZAROTDS ; 1135
Extended Rotary handle EZAROTE 1670
Shunt Release
AC
100-130 V EZASHT100AC
200-277 V EZASHT200AC ; 1710
380-480 V EZASHT380AC
DC
24 V EZASHT024DC
1710
48 V EZASHT048DC
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 43
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
s¬ICS¬¬¬)CU¬AS¬PER¬)%#¬
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510300 ; LV510310
25A LV510301 ; LV510311 ;
32A LV510302 ; LV510312 ;
40A LV510303 ; LV510313 ;
6690 9300
50A LV510304 ; LV510314
25kA 63A LV510305 ; LV510315 ;
80A LV510306 ; LV510316 ;
100A LV510307 ; LV510317 ;
125A LV516302 ; 9750 LV516312 ; 11790
160A LV516303 ; 12720 LV516313 ; 15060
200A LV525302 ; 16840 LV525312 20800
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
25kA 250A LV525303 ; 19610 LV525313 23830
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510330 ; LV510340
25A LV510331 ; LV510341
32A LV510332 ; LV510342 ;
40A LV510333 ; LV510343 ;
9050 11240
50A LV510334 ; LV510344
36kA 63A LV510335 ; LV510345 ;
80A LV510336 ; LV510346
100A LV510337 ; LV510347 ;
125A LV516332 ; 10020 LV516342 12350
160A LV516333 ; 13270 LV516343 15690
200A LV525332 19110 LV525342 ; 23520
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525333 21200 LV525343 ; 26040
320A LV540305 27440 LV540308 ; 34040
36kA 400A LV540306 27590 LV540309 ; 34340
500A LV563305 ; 29650 LV563308 ; 37360
6!
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
16A LV510470 ; LV510480
25A LV510471 LV510481
32A LV510472 ; LV510482 ;
40A LV510473 LV510483
11850 14570
50A LV510474 LV510484
50kA 63A LV510475 ; LV510485 ;
80A LV510476 ; LV510486
100A LV510477 ; LV510487 ;
125A LV516462 ; 15190 LV516467 16620
160A LV516463 ; 16440 LV516468 19580
200A LV525452 21280 LV525457 ; 26730
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525453 22870 LV525458 ; 28190
320A LV540315 ; 27910 LV540318 34340
50kA 400A LV540316 ; 28120 LV540319 ; 34970
500A LV563315 ; 32610 LV563318 40940
6!
Note:
s¬¬&OR¬PERFORMANCE¬AND¬OTHER¬DETAILS¬CONTACT¬OUR¬NEAREST¬3ALES¬/FFICE
¬
!¬ ¬0C & 600A @ 400 C for TMD630A MCCB
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 44
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Ics Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
35kA 800A LV580300 ; 53330 LV580301 ; 57550
50kA 800A LV580302 ; 58370 LV580303 ; 65960
Current Rating 2.5 6.3 12.5 25 50 100 150 220 320 500
CVS 100 6..14In
CVS 160/250 9..14In
CVS 400 6..13In
CVS 630 6..13In
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 45
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
s¬ Rated Current, In (A) – 25, 40, 100, 160, 250, 400, 630
s¬ "REAKING¬CAPACITY¬)CU)CS ¬K! ¬AT¬6¬n¬
¬¬
s¬ 3 Pole and 4 pole versions.
s¬ Built-in μP based trip unit having protection functions LSIG. Variable
current setting for L,S,I and G and variable time delay setting for L,S and G.
s¬ Neutral O/L protection possible with 3P MCCB (with External Neutral CT)
and 4P MCCB
s¬ Last Fault trip history on LCD screen of MCCB i.e Faulty phase, Type of
Fault and interrupted current.
s¬ Same accessories of present ECVS range
¬ONLY¬UPTO¬!
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 46
Easy-Pact CVS Switch Disconnector Version
Rated Current Three Pole Reference Unit MRP [`] Four Pole Reference Unit MRP [`]
Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 47
EasyPact CVS Accessories for EasyPact CVS
Indication contacts Voltage Release Padlocking accessory Direct Rotary Handle Extended Rotary Handle
Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 ; LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 ; LV429406 ;
2250 2930
220-240 V 50/60 Hz LV429387 ; LV429407 ;
380-415 V 50 Hz LV429388 ; LV429408 ;
525 V 50 Hz LV429389 LV429409
DC
12 V LV429382 LV429402
24 V LV429390 ; LV429410 ;
30 V LV429391 LV429411
48 V LV429392 2250 LV429412 2930
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414
Rotary Handles
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Direct rotary handle
Standard black handle LV429337 ; 1165 LV432597 ; 1750
Extended rotary handle
Standard extended rotary handle LV429338 ; 1770 LV432598 ; 3140
Installation Accessories
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV431563 ; 620 32492 ; 1400
Spreaders (Set of 4) 4P LV431564 ; 820 32493 ; 1780
Phase Barriers (Set of 6)
LV432570 ; 750
Interlocking
For Breaker with Rotary Handle LV429369 8655 LV432621 10895
For Breaker with Toggle LV429354 9465 LV432614 10895
Mechanical Interlocking with Base Plate 2
18560 3
39090
Locking of Rotary Handle
Locking Device LV429344 ; 550 LV432604 ; 750
Ronis Keylock (1 Lock + 1 Key set) 41940 ; 3785 41940 ; 3785
Ronis Keylock (2 Locks + 1 Key set) 41950 ; On request 41950 ; On request
Profalux Keylock (1 Lock + 1 Key set) 42888 6385 42888 6385
Profalux Keylock (2 Locks + 1 Key set) 42878 7290 42878 7290
¬SUPPLIED¬AS¬STANDARD¬WITH¬SPREADERS
¬-ECHANICAL¬)NTERLOCKING¬WITH¬"ASE¬0LATE¬TO¬BE¬ORDERED¬WITH¬3AFETY¬TRIP¬INTERLOCK¬,6¬FOR¬¬AND¬,6¬FOR¬
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 48
EasyPact CVS Accessories for EasyPact CVS
Unit LP
Description Reference
[`]
Mechanical interlocking for circuit breakers
With toggles 100A to 250A LV429354 9465
With rotary handles 100A -250A LV429369 8655
With toggles 400A to 630A LV432614 10895
With rotary handles 400A to 630A LV432621 10895
Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
220-240 V 50/60 Hz LV580061 2350 LV580071 2700
Rotary Handles
800A Unit LP
Description
Reference [`]
Extended rotary handle
Standard extended rotary handle LV580081 ; 2060
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 49
EasyPact EZC
With just three sizes of circuit breakers, Schneider Electric’s EasyPact EZC system is the simple, universal solution, particularly
adapted to Buildings and OEM segments
s¬Suitability for Isolation ensures safety
s¬Compliance to RoHS (Restriction of Hazardous Substances) for environment safety
Range Details:
s¬Global MCCB offer from 15A to 600A
s¬Breaking capacity upto 50kA @ 415 V AC
s¬1P, 2P, 3P and 4P versions available
s¬EZC AC version is suitable for DC applications upto 250V DC (15A to 250A breaking capacity up to 30kA)
s¬Built in Earth leakage version 63A to 250A @ Icu36kA.
Breaking capacity
DB402889_1
Icu kA at 400/415V AC
50
EZC400H EZC630H
36
EZC250H EZCV250H EZC400N EZC630N
30
EZC100H
25
EZC250N EZCV250N
18
15 EZC250F
EZC100N
10
EZC100F
7.5
EZC100B
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 50
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network
s¬ Conforms to IEC60947-2
s¬ Suitable for isolation
s¬ Suitable for EasyPact Busbar system
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
16A EZC100F3016
20A EZC100F3020
25A EZC100F3025
32A EZC100F3032
“10 kA @ 415V AC
40A EZC100F3040 2820
5kA @ 250V DC (2pole in series)”
50A EZC100F3050
63A EZC100F3063
80A EZC100F3080
100A EZC100F3100
125A EZC250F3125 6635
150A EZC250F3150 6680
“18 kA @ 415V AC
160A EZC250F3160 7575
5kA @ 250V DC (2pole in series)”
175A EZC250F3175
9305
200A EZC250F3200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“18 kA @ 415V AC
250A EZC250F3250 10885
5kA @ 250V DC (2pole in series)”
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Single Pole
[`]
16A EZC100N1016
20A EZC100N1020
25A EZC100N1025
32A EZC100N1032
"18 kA @ 240V AC
40A EZC100N1040 2070
5kA @ 125V DC "
50A EZC100N1050
63A EZC100N1063
80A EZC100N1080
100A EZC100N1100
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Two Pole Reference
[`]
16A EZC100H2016
20A EZC100H2020
25A EZC100H2025
32A EZC100H2032
“50 kA @ 240V AC
40A EZC100H2040 3375
10kA @ 250V DC (2pole in series)”
50A EZC100H2050
63A EZC100H2063
80A EZC100H2080
100A EZC100H2100
125A EZC250H2125 7015
150A EZC250H2150 8265
“85 kA @ 240V AC
160A EZC250H2160 8265
30kA @ 250V DC (2pole in series)”
175A EZC250H2175
9950
200A EZC250H2200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“85 kA @ 240V AC
250A EZC250H2250 10245
30kA @ 250V DC (2pole in series)”
Note:
s¬Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
s¬630A and other breaking capacity versions on request.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 51
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
15A EZC100H3015 EZC100H4015
20A EZC100H3020 EZC100H4020
25A EZC100H3025 EZC100H4025
32A EZC100H3032 EZC100H4032
“30 kA @ 415V AC
40A EZC100H3040 4550 EZC100H4040 6300
10kA @ 250V DC (2pole in series)”
50A EZC100H3050 EZC100H4050
63A EZC100H3063 EZC100H4063
80A EZC100H3080 EZC100H4080
100A EZC100H3100 EZC100H4100
125A EZC250N3125 6795 EZC250N4125 9380
“25 kA @ 415V AC
160A EZC250N3160 8240 EZC250N4160 11035
20kA @ 250V DC (2pole in series)”
200A EZC250N3200 9780 EZC250N4200 12335
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
"25 kA @ 415V AC
250A EZC250N3250 11175 EZC250N4250 14460
20kA @ 250V DC (2pole in series)"
Breaking Capacity Icu as per Rated Current Three Pole Reference Unit MRP Four Pole Unit MRP
IEC 60947-2 [`] Reference [`]
125A EZC250H3125 6990 EZC250H4125 9430
"36 kA @ 415V AC
160A EZC250H3160 9160 EZC250H4160 11520
30kA @ 250V DC (2pole in series)"
200A EZC250H3200 11370 EZC250H4200 15360
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
“36 kA @ 415V AC
250A EZC250H3250 12710 EZC250H4250 17170
30kA @ 250V DC (2pole in series)”
320A EZC400H3320N 19030 EZC400H4320N 21950
400A EZC400H3400N 19640 EZC400H4400N 26290
“50 kA @ 415V AC“
500A EZC630H3500N 25830 EZC630H4500N 33570
600A EZC630H3600N 26920 EZC630H4600N 35090
Note:
t Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
t 630A and other breaking capacity versions on request.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 52
EasyPact EZC Accessories
Unit LP
Description EZC 400/600 Reference
[`]
Auxiliary Contacts
OF or SD or SDE 29450 880
Spreaders
Spreaders (Set of 3) 3P 32492 1400
Spreaders (Set of 4) 4P 32493 1780
Phase Barriers (Set of 6) LV432570 750
Rotary Handle
Direct Rotary handle LV432597 1750
Extended Rotary handle LV432598 3140
Shunt Release
AC 220-240 V 50/60 Hz LV429387 2100
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 53
EasyPact NKS Moulded Case Circuit Breakers for
Distribution Network
AC MCCB
Fixed Thermal Magnetic Trip Unit (TMD)
s¬Conforms to IEC60947-2
Unit MRP
Breaking Capcity Icu as per IEC60947-2 Rated Current Reference
[`]
15 NKS100R015AC3P
20 NKS100R020AC3P
25 NKS100R025AC3P
32 NKS100R032AC3P
40 NKS100R040AC3P 1730
50 NKS100R050AC3P
63 NKS100R063AC3P
75 NKS100R075AC3P
10kA
100 NKS100R100AC3P
110 NKS160R110AC3P
3950
125 NKS160R125AC3P
140 NKS160R140AC3P
150 NKS160R150AC3P 4410
160 NKS160R160AC3P
175 NKS200R175AC3P
5770
200 NKS200R200AC3P
*Ics=5kA
Note:
t Contact customer care for other accessories
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 54
Simpact NKS DC MCCB
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 55
Unique Modular Ground Fault Protection
Note: Kindly order one no. Shunt trip coil along with one Ground Fault Protection Module for CVS100 to 630. Order one auxiliary contact alongwith shunt coil for
CVS800.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 56
Earth Leakage Protection
Earth Leakage Protection is obtained by: Fitting a VIGI Module on the Circuit Breakers
VIGI Module Earth Leakage Device for EasyPact CVS/ ComPact NSX Range Moulded
Case Circuit Breakers
s¬ Compliance with Standards - IEC60947-2 appendix B, IEC 60255-4 and IEC60801-2 to 5 covering protection against
nuisance tripping due to:
° Transient overvoltages, lightning strikes
° Switching of devices on the distribution system
° Electrostatic discharges and radio frequency disturbances
s¬ Device can be equipped with multifunction aux contact of MCCB to remotely signal tripping due to earth fault
s¬ Self powered - “no aux supply required”
s¬ Instantaneous tripping at 30mA in less the 40ms for human protection
s¬ Direct acting device - no shunt/UV release required in MCCB
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 57
Vigirex Earth Leakage Protection Relay
Vigirex Relays
Vigirex Relays along with Vigirex Sensors, may be may be used to add external Earth Leakage Protection to Circuit Breakers
s¬ Sensitivity Adjustments from 30mA to 30A and time delay settings from (0-4.5 seconds)
s¬ Closed Toroid up to 630A (30 to 300mm in diameter), Split Toroid up to 250A (46 to 110mm in diameter) or
s¬ Rectangular sensor up to 3200A
s¬ 400Hz Distribution System
Note: For further details, please contact our nearest Sales Office.
Din rail mount Unit MRP Front panel mount Unit MRP
Type Control Voltage
Reference [`] Reference [`]
RH10 with local manual fault reset 220/240VAC 56130 56230
10495 11530
SENSITIVITY! 380/415VAC 56140 56240
RH99 with local manual fault reset 220/240VAC 56173 15860 56273 17170
SENSITIVITY¬¬
¬!¬¬TIME¬DELAY¬
S 380/415VAC 56174 17490 56274 18030
RH197P with local manual or automatic fault reset 220/240VAC - 5
19415
SENSITIVITY¬¬
¬!¬¬TIME¬DELAY¬
S 380/415VAC - 5
28850
RH197P with local manual or automatic fault reset 220/240VAC - 5
27750
SENSITIVITY¬¬
¬!¬¬TIME¬DELAY¬
S 380/415VAC - 5
20580
¬ALARM¬AT¬¬OF ¬FAULT¬THRESHOLD
¬ALARM¬AT¬¬OF ¬FAULT¬THRESHOLD
Vigirex Sensors
Note: For vigirex relay with monitoring and communication facility, contact nearest sales office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 58
ComPact- INS & INV Switch Disconnectors
For Low Voltage Circuit Control and Isolation - Incomers for Distribution Boards
s¬ Conforms to IEC 60947-3/IS 13947 - 3
s¬ Rated operational voltages 500V/690V
s¬ Range 40A to 2500A
s¬ Rated operational current @ AC 23A
s¬ No deration upto 60° C
s¬ Positive contact indication
s¬ Common accessories with ComPact NSX/single auxillary contact
s¬ Making capacity enhanced with ComPact NSX upstream
Accessories
Optional front extended rotary handle INS 250 - black handle (Switch Disconnector) LV431050 3895
Optional front extended rotary handle INS 320..630 - black handle (Switch Disconnector) 31052 5510
Optional front extended rotary handle INS 40..160 - black handle (Switch Disconnector) LV428941 1980
6 phase separators - INS100..160 28959 865
6 phase separators - INS250 29329 1080
6 phase separators - INS400..630 LV432570 750
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 59
SDF Switch Disconnector Fuse units
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 60
Fupact Switch Disconnector Fuse units
s¬ Complete Range from 32 to 630A in TP, TP+N & FP version suitable for
DIN/BS fuses.
s¬ 4 breaks and 8 arcing points
s¬ IP20 Fuse Protection Cover is standard
s¬ Higher Mechanical and Electrical life.
Without Enclosure
Rated Operational DIN Type Unit LP BS Type Unit LP
Poles Description
Current Reference [`] Reference [`]
32 A 3P + N NX032TPNDI ; 2390 NX032TPNBS 2360
63 A 3P + N NX063TPNDI ; 3160 NX063TPNBS 3130
80 A 3P + N NX080TPNDI 5970 NX080TPNBS 5690
3P NX100TPXDI 6590
100 A 3P + N NX100TPNDI ; 6850 NX100TPNBS 6790
4P NX100FPXDI 7120
3P NX125TPXDI ; 7690
125 A 3P + N NX125TPNDI ; 8400 NX125TPNBS 8310
4P NX125FPXDI 9450
3P NX160TPXDI 8470
160 A 3P + N NX160TPNDI ; 9160 NX160TPNBS 8620
4P NX160FPXDI 10550
3P NX200TPXDI 11210
200 A 3P + N NX200TPNDI ; 11760 NX200TPNBS 10340
4P NX200FPXDI 13160
3P NX250TPXDI 13740
250 A 3P + N NX250TPNDI ; 14150 NX250TPNBS 13590
4P NX250FPXDI 16650
3P NX315TPXDI 17270
315 A 3P + N NX315TPNDI ; 17520 NX315TPNBS 17240
4P NX315FPXDI On request
3P NX400TPXDI 23090
400 A 3P + N NX400TPNDI ; 23960 NX400TPNBS 22650
4P NX400FPXDI 28880
3P NX630TPXDI 34080
630 A 3P + N NX630TPNDI ; 34860 NX630TPNBS 34500
4P NX630FPXDI 38870
Accessories/Spares
NX032/NX063/NX080
Auxiliary contact for Fupact NXAA11 ; 500
Fuse holder for DIN NX032...NX080 NXHD1 240
Handle operating mechanism (HOM) NX032...NX080 NXR1 445
HOM shaft for NX/32/63/80 NXRS1 240
NX100/NX125/NX160
Auxiliary contact for Fupact NXBA11 ; 580
Fuse holder DIN for BS type NX100...NX160 NXHB21 220
Fuse holder DIN for NX100...NX160 NXHD21 On request
Handle operating mechanism NX100...NX160 NXR2 ; 850
Shaft for HOM for NX100...NX160 NXRS2 240
NX200
Auxiliary contact for Fupact NXBA11 ; 580
Fuse holder for BS type NX200 NXHB22 230
Fuse holder for DIN NX200 NXHD22 260
Handle operating mechanism NX200 NXR2 ; 850
Shaft for HOM for NX200 NXRS2A 295
NX250/315/400
Auxiliary contact for Fupact NXBA11 ; 580
Handle operating mechanism for NX250...NX400 NXR3 880
Shaft for HOM for NX250…NX400 NXRS3 295
NX630
Auxiliary contact for Fupact NXBA11 ; 580
Handle operating mechanism for NX630 NXR4 On request
Shaft for HOM for NX630 NXRS4 On request
Note: For other versions please contact our nearest Sales Office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 61
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 62
Future of Power Distribution
MasterPact MTZ
LV Circuit Breakers & Switch Disconnector
from 630A to 6300A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 63
Built on the legendary performance and reliability of
the MasterPact range.
MasterPact MTZ circuit breakers prepare you for the future of power distribution with smart connectivity, remote
monitoring, and easy customization via digital modules.
s¬)NTUITIVE¬%CO3TRUXURE¬0OWER¬$EVICE¬!PP¬SMARTPHONE¬ s¬3EAMLESS¬INTEGRATION¬WITH¬BUILDING¬AND¬ENERGY¬
app for easy operation and maintenance management systems with EcoStruxure architectures
s¬0RECISE¬#LASS¬¬POWER¬METER¬BUILT¬IN¬FORëENERGY
s¬¬$ESIGNED¬AND¬TESTED¬TO¬APPLICABLE¬STANDARDS¬FOR¬
saving capabilities ANSI, UL, and IEC
s¬¬%ASY¬CUSTOMIZATION¬WITH¬DIGITAL¬MODULES s¬¬,OW¬MIGRATION¬COST¬FROM¬-ASTER0ACT¬.4.7¬
s¬)NTUITIVE¬-ICRO,OGICTM X control unit to MasterPact MTZ
s¬%ASY¬INSTALLATION¬USING¬ESTABLISHED¬ARCHITECTURES
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 64
MasterPact MTZ
MySE
Order your MasterPact MTZ online
EcoStruxure Power
BUILD AND Commision software
Commission and upgrade
COMMISSION easily with protection setting
and factory-acceptance test.
CUSTOMIZE OK
OR UPGRADE
GoDigital store
Purchase additional digital modules
for even more visibility and efficiency
over the MasterPact MTZ circuit
breaker life cycle.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 65
MasterPact MTZ
Measurement Maintenance
Energy management is & Diagnostics
the challenge of present Optimal continuity of ser-
& future generations. vices as well as extended
To meet this requirement life of equipment is one of
MicroLogic X incorporates customers main concerns.
all the measuring functions For that purpose Micro-
of a power meter including Logic X integrates new
Energy Class 1 accuracy extended diagnosis and
third-party certified. assistance to maintenance.
- e.eps
PB116185_35Copi
Protection
Improvement of the relia-
bility of MicroLogic X,
dual settings and additio-
nal facilities increase the
performance and the
flexibility of low voltage
systems of protection.
se.com/in 66
The Benchmark for Power Circuit Breakers around the world
MasterPact NT/NW
LV power circuit breakers 630 to 6300 A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
Network Protection Supervision ComPact
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 67
MasterPact NT and NW
Ethernet ready MasterPact NT and NW breakers, setting the standard for performance, safety, connectivity and
built-in metering; all in optimized frame sizes
s¬ %THERNET¬BASED¬MONITORING¬CONTROL¬ALARM¬NOTIlCATION¬FOR¬ENERGY¬ASSET¬AND¬NETWORK¬MANAGEMENT
s¬ "UILT
IN¬ENERGY¬METERING¬WITH¬COMBINED¬ACCURACY¬CLASS¬OF ¬¬FOR¬IMPROVED¬ENERGY¬EFlCIENCY¬
s¬ -ASTER0ACT¬IS¬SUITABLE¬FOR¬HEAVY¬DUTY¬APPLICATIONS
Range Details:
s¬ !¬TO¬!
s¬ "REAKING¬#APACITY¬UPTO¬K!
s¬ &IXED¬$RAW¬OUT¬TYPE
s¬ &LEXIBLE¬TERMINAL¬ORIENTATION¬ENABLES¬HORIZONTAL¬OR¬VERTICAL¬ALIGNMENT¬CHANGES¬IN¬THE¬lELD
.OT¬!PPLICABLE¬FOR¬!¬AND¬!
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 68
MicroLogic Trip System Overview of functions
X: type of protection
2 for basic protection
5 for selective protection
6 for selective + earth-fault protection
7 for selective + earth-leakage protection.
Y: control-unit generation
Identification of the control-unit generation.
“0” signifies the first generation.
Z: type of measurement
E for” Energy”
P for “power meter”
H for “harmonic meter”.
I1, I2, I3, IN, Iearth-fault, Iearth-leakage and maximeter for these measurements
fault indications
settings in amperes and in seconds.
calculates the current demand value P: E + power meter + programmable protection
“Quickview” function for the automatic cyclical measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, Vpeak, Apeak, power
display of the most useful values (as standard factor and maximeters and minimeters
or by selection). IDMTL long-time protection, minimum and maximum voltage and frequency,
voltage and current imbalance, phase sequence, reverse power
load shedding and reconnection depending on power or current
measurements of interrupted currents, differentiated fault indications,
maintenance indications, H: P + harmonics
event histories and
time-stamping, etc. power quality: fundamentals, distortion, amplitude and
phase of harmonics up to the 31st order
waveform capture after fault, alarm or on request
enhanced alarm programming: thresholds and actions.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 69
MicroLogic Trip Unit
Energy efficiency, now within your reach
Micrologic 6.0 E
100 %
40 %
menu
long time
alarm
short time
ground fault
ATS Kit
Suitable for MasterPact NT/ NW ACB
This Kit comprises of :
p Adaptation fixture & set of two cables for mechanical interlocking
p IVE unit for Electrical Interlocking
p ACP control Plate
p UA/BA controller
*Note: For ATS with MasterPact NT/NW ACB, order 2 nos. of ACB’s with ready to close PF contact + 1 no. ATS Kit
Unit MRP
Description Reference
[`]
ATS Kit for MasterPact NT EDO type with BA 415VAC controller INA_NTDOB4 On request
ATS Kit for MasterPact NT EDO type with UA 415VAC controller INA_NTDOU4 On request
ATS Kit for MasterPact NW EDO type with BA 415VAC controller INA_NWDOB4 ; On request
ATS Kit for MasterPact NW EDO type with UA 415VAC controller INA_NWDOU4 ; On request
!43¬+IT¬WITH¬FOR¬&IXED¬"REAKER¬AND¬"!¬CONTROLLER¬WITH¬6!#¬CONTACT¬OUR¬CUSTOMER¬CARE
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 70
The easy choice for reliable performance
EasyPact MVS
LV power circuit breakers and switch
disconnectors from 800 to 4000 A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 71
EasyPact MVS
Range Details:
t Single frame for 800A to 4000A
t Fixed, Draw out type
t ENTIRE¬2ANGE¬)CU)CS)CWK!¬FOR¬SEC¬ 6
t Suitability for applications up to 690 V
t FLEXIBLE¬TERMINAL¬ORIENTATION¬ENABLES¬HORIZONTAL¬OR¬VERTICAL¬ALIGNMENT¬CHANGES¬IN¬THE¬FIELD
.OT¬POSSIBLE¬FOR¬!
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 72
ET/ETA/ETV Trip System
Voltage Metering
ZSI
Features
% Loading Bar Graph for each
phase
Thermal Memory
2 (L, I) 2L 2A 2V
Protection
6 (L,S,I,G) 6G 6A 6V
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 73
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
s¬ Conforms to IS/ IEC 60947-2 & 3
s¬ Microprocessor based ET trip systems with thermal memory
s¬ No derating up to 50˚C
s¬ Zone Selective Interlocking
s¬ Fully rated neutral with inbuilt protection
s¬ Pre trip alarm & individual fault indicating LEDs
s¬ ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
s¬ )CU)CS)CWSEC ¬¬K!¬ ¬6¬!#
Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit LP Unit LP Unit LP Unit LP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW6L 190010 MVS08N3NW6L 239900 MVS08N4MW6L 238480 MVS08N4NW6L 288370
1000 MVS10N3MW6L 199610 MVS10N3NW6L 249500 MVS10N4MW6L 249860 MVS10N4NW6L 299750
1250 MVS12N3MW6L 222250 MVS12N3NW6L 272140 MVS12N4MW6L 276730 MVS12N4NW6L 326620
1600 MVS16N3MW6L 252600 MVS16N3NW6L 302490 MVS16N4MW6L 308220 MVS16N4NW6L 358110
2000 MVS20N3MW6L 311620 MVS20N3NW6L 361510 MVS20N4MW6L 382700 MVS20N4NW6L 432590
2500 MVS25N3MW6L 385250 MVS25N3NW6L 435140 MVS25N4MW6L 468140 MVS25N4NW6L 518030
3200 MVS32N3MW6L 467820 MVS32N3NW6L 517710 MVS32N4MW6L 573620 MVS32N4NW6L 623510
4000 MVS40N3MW6L 572170 MVS40N3NW6L 622060 MVS40N4MW6L 731820 MVS40N4NW6L 781710
Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MW0D
ACB with ET6A trip unit Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
Add `9200
(LCD display with Current Metering) ACB reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MW6A
¬3AME¬0HILOSOPHY¬FOR¬¬0OLE¬¬0OLE¬AND¬-ANUAL¬%LECTRICAL¬2EFERENCES
Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 74
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
s¬ Conforms to IS/ IEC 60947-2 & 3
s¬ Microprocessor based ET trip systems with thermal memory
s¬ No derating up to 50˚C
s¬ Fully rated neutral with inbuilt protection
s¬ Pre trip alarm & individual fault indicating LEDs
s¬ ET2L provides Overload & Short-circuit protections
s¬ )CU)CS)CWSEC ¬¬K!¬ ¬6¬!#
Draw-out Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit LP Unit LP Unit LP Unit LP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW2L 182610 MVS08N3NW2L 232500 MVS08N4MW2L 231080 MVS08N4NW2L 280970
1000 MVS10N3MW2L 192210 MVS10N3NW2L 242100 MVS10N4MW2L 242460 MVS10N4NW2L 292350
1250 MVS12N3MW2L 214850 MVS12N3NW2L 264740 MVS12N4MW2L 269330 MVS12N4NW2L 319220
1600 MVS16N3MW2L 245200 MVS16N3NW2L 295090 MVS16N4MW2L 300820 MVS16N4NW2L 350710
2000 MVS20N3MW2L 304220 MVS20N3NW2L 354110 MVS20N4MW2L 375300 MVS20N4NW2L 425190
2500 MVS25N3MW2L 377850 MVS25N3NW2L 427740 MVS25N4MW2L 460740 MVS25N4NW2L 510630
3200 MVS32N3MW2L 460420 MVS32N3NW2L 510310 MVS32N4MW2L 566220 MVS32N4NW2L 616110
4000 MVS40N3MW2L 564770 MVS40N3NW2L 614660 MVS40N4MW2L 724420 MVS40N4NW2L 774310
ACB with ET2A trip unit (LCD display with Example : ACB reference with ET2L trip unit - MVS08N3MW2L. For ACB
Add `4600
Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MW2A
!#
¬3AME¬0HILOSOPHY¬FOR¬¬0OLE¬¬0OLE¬AND¬-ANUAL¬%LECTRICAL¬2EFERENCES
Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 75
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
s¬ Conforms to IS/ IEC 60947-2 & 3
s¬ Microprocessor based ET trip systems with thermal memory
s¬ No derating up to 50˚ C
s¬ Zone Selective Interlocking
s¬ Fully rated neutral with inbuilt protection
s¬ Pre trip alarm & individual fault indicating LEDs
s¬ )CU)CS)CWSEC ¬K!¬ ¬6¬!#
Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
Rating 3P Fix Manual Unit LP 3P Fix Electrical Unit LP 4P Fix Manual Unit LP 4P Fix Electrical Unit LP
in (A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF6L 141680 MVS08N3NF6L 191570 MVS08N4MF6L 180140 MVS08N4NF6L 230030
1000 MVS10N3MF6L 155090 MVS10N3NF6L 204980 MVS10N4MF6L 195640 MVS10N4NF6L 245530
1250 MVS12N3MF6L 178260 MVS12N3NF6L 228150 MVS12N4MF6L 222710 MVS12N4NF6L 272600
1600 MVS16N3MF6L 197870 MVS16N3NF6L 247760 MVS16N4MF6L 255770 MVS16N4NF6L 305660
2000 MVS20N3MF6L 234630 MVS20N3NF6L 284520 MVS20N4MF6L 306640 MVS20N4NF6L 356530
2500 MVS25N3MF6L 286040 MVS25N3NF6L 335930 MVS25N4MF6L 361390 MVS25N4NF6L 411280
3200 MVS32N3MF6L 409460 MVS32N3NF6L 459350 MVS32N4MF6L 505200 MVS32N4NF6L 555090
4000 MVS40N3MF6L 504240 MVS40N3NF6L 554130 MVS40N4MF6L 632160 MVS40N4NF6L 682050
Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MF0D
ACB with ET6A trip unit (LCD display Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For ACB
Add `9200
with Current Metering) reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MF6A
¬3AME¬0HILOSOPHY¬FOR¬¬0OLE¬¬0OLE¬AND¬-ANUAL¬%LECTRICAL¬2EFERENCES
Note:
All Fix type circuit breakers will be supplied with:
(i) horizontal / vertical terminal
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) door sealing frame- Escutcheon (CDP).
s¬ !LL¬SWITCH¬DISCONNECTORS¬ARE¬WITHOUT¬PROTECTION
s¬ !LL¬ELECTRICAL¬OPERATED¬BREAKERS¬ARE¬SUPPLIED¬WITH¬MOTOR¬MECHANISM¬-#( ¬CLOSING¬COIL¬8& ¬¬SHUNT¬RELEASE¬-8
s¬ %XTERNAL¬.EUTRAL¬#4¬REQUIRED¬FOR¬HIGHLY¬UN
BALANCED¬40
.¬SYSTEM¬HAS¬TO¬BE¬ORDERED¬AT¬EXTRA¬PRICE
s¬ !NY¬OTHER¬ACCESSORIES¬ARE¬OPTIONAL¬AT¬EXTRA¬PRICE
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 76
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
s¬ Conforms to IS/ IEC 60947-2 & 3
s¬ Microprocessor based ET trip systems with thermal memory
s¬ No derating up to 50° C
s¬ Fully rated neutral with inbuilt protection
s¬ Pre trip alarm & individual fault indicating LEDs
s¬ ¬)CU)CS)CWSEC ¬K!¬ ¬6¬!#
Fixed Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
Rating in 3P Fix Manual Unit LP 3P Fix Electrical Unit LP 4P Fix Manual Unit LP 4P Fix Electrical Unit LP
(A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF2L 134280 MVS08N3NF2L 184170 MVS08N4MF2L 172740 MVS08N4NF2L 222630
1000 MVS10N3MF2L 147690 MVS10N3NF2L 197580 MVS10N4MF2L 188240 MVS10N4NF2L 238130
1250 MVS12N3MF2L 170860 MVS12N3NF2L 220750 MVS12N4MF2L 215310 MVS12N4NF2L 265200
1600 MVS16N3MF2L 190470 MVS16N3NF2L 240360 MVS16N4MF2L 248370 MVS16N4NF2L 298260
2000 MVS20N3MF2L 227230 MVS20N3NF2L 277120 MVS20N4MF2L 299240 MVS20N4NF2L 349130
2500 MVS25N3MF2L 278640 MVS25N3NF2L 328530 MVS25N4MF2L 353990 MVS25N4NF2L 403880
3200 MVS32N3MF2L 402060 MVS32N3NF2L 451950 MVS32N4MF2L 497800 MVS32N4NF2L 547690
4000 MVS40N3MF2L 496840 MVS40N3NF2L 546730 MVS40N4MF2L 624760 MVS40N4NF2L 674650
ACB with ET2A trip unit (LCD display Example : ACB reference with ET2L trip unit - MVS08N3MF2L. For ACB
Add `4600
with Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MF2A
¬3AME¬0HILOSOPHY¬FOR¬¬0OLE¬¬0OLE¬AND¬-ANUAL¬%LECTRICAL¬¬2EFERENCES
Note:
s¬ ¬ LL¬SWITCH¬DISCONNECTORS¬ARE¬WITHOUT¬PROTECTION
!
s¬ ¬!LL¬ELECTRICAL¬OPERATED¬BREAKERS¬ARE¬SUPPLIED¬WITH¬MOTOR¬MECHANISM¬-#( ¬CLOSING¬COIL¬8& ¬¬SHUNT¬RELEASE¬-8
s¬ ¬%XTERNAL¬.EUTRAL¬#4¬REQUIRED¬FOR¬HIGHLY¬UN
BALANCED¬40
.¬SYSTEM¬HAS¬TO¬BE¬ORDERED¬AT¬EXTRA¬PRICE
s¬ ¬!NY¬OTHER¬ACCESSORIES¬ARE¬OPTIONAL¬AT¬EXTRA¬PRICE
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 77
EasyPact MVS Accessories
Terminal Block
For drawout circuit breaker 47849 210
Under Voltage Release (MN)
24/30 V DC, 24 V AC 33668
48/60 V DC, 48 V AC 33669
AC 50/60 Hz DC 100/130 V AC/DC 33670 ; 5780
200/250 V AC/DC 33671 ;
380/480 V AC 33673 ;
MN Delay Unit
48/60 V AC/DC 33680
100/130 V AC/DC 33681
Rr (adjustable) 8400
200/250 V AC/DC 33682
AC 50/60 Hz DC
380/480 V AC/DC 33683
100/130 V AC/DC 33684
R (non-adjustable) 7820
200/250 V AC/DC 33685 ;
ON/OFF Indication Contacts (Additional OF contact)
1 additional block of 4 contacts 47887 5090
Door Interlock (VPECD)/1 part
On right hand side of chassis 47914 ; 2780
Operation Counter
Operation Counter CDM 48535 7880
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 78
EasyPact SPS
800-1600A
ET2.0 ET6G
Trip System Trip System
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 79
EasyPact SPS Draw-out type Circuit breakers and
Switch Disconnectors 800-1600A
s¬ All EasyPact SPS Air Circuit Breakers are equipped with terminal adaptors
s¬ Conforms to IS/ IEC 60947-2 & 3
s¬ Microprocessor based ET trip systems with thermal memory
s¬ Fully rated neutral with inbuilt protection
s¬ ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
s¬ ET2B provides Overload & Short-circuit protections
s¬ Short circuit breaking capacity 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW6L 146220 SPS08F3PEW6L 186720 SPS08F4PMW6L 183360 SPS08F4PEW6L 223860
1000 SPS10F3PMW6L 153210 SPS10F3PEW6L 193710 SPS10F4PMW6L 193970 SPS10F4PEW6L 234470
1250 SPS12F3PMW6L 171360 SPS12F3PEW6L 211860 SPS12F4PMW6L 218560 SPS12F4PEW6L 259060
1600 SPS16F3PMW6L 193320 SPS16F3PEW6L 233820 SPS16F4PMW6L 247400 SPS16F4PEW6L 287900
Draw-out Type circuit breaker with Microprocessor based ET2B Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW2B 144420 SPS08F3PEW2B 184920 SPS08F4PMW2B 181560 SPS08F4PEW2B 222060
1000 SPS10F3PMW2B 151410 SPS10F3PEW2B 191910 SPS10F4PMW2B 192170 SPS10F4PEW2B 232670
1250 SPS12F3PMW2B 169560 SPS12F3PEW2B 210060 SPS12F4PMW2B 216760 SPS12F4PEW2B 257260
1600 SPS16F3PMW2B 191520 SPS16F3PEW2B 232020 SPS16F4PMW2B 245600 SPS16F4PEW2B 286100
Note:
All draw-out type circuit breakers will be supplied with:
(i) Vertical-vertical terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
s¬ !LL¬SWITCH¬DISCONNECTORS¬ARE¬WITHOUT¬PROTECTION
s¬ !LL¬ELECTRICAL¬OPERATED¬BREAKERS¬ARE¬SUPPLIED¬WITH¬MOTOR¬MECHANISM¬-#( ¬CLOSING¬COIL¬8& ¬AND¬SHUNT¬RELEASE¬-8
s¬ %XTERNAL¬.EUTRAL¬#4¬REQUIRED¬FOR¬HIGHLY¬UN
BALANCED¬40
.¬SYSTEM¬HAS¬TO¬BE¬ORDERED¬AT¬EXTRA¬PRICE
s¬ !NY¬OTHER¬ACCESSORIES¬ARE¬OPTIONAL¬AT¬EXTRA¬PRICE
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 80
EasyPact SPS Fixed type Circuit breakers and
Switch Disconnectors 800-1600A
s¬ All EasyPact SPS Air Circuit Breakers are equipped with terminal adaptors
s¬ Conforms to IS/ IEC 60947-2 & 3
s¬ Microprocessor based ET trip systems with thermal memory
s¬ Fully rated neutral with inbuilt protection
s¬ ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
s¬ ET2B provides Overload & Short-circuit protections
s¬ Short circuit breaking capacity 50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit
3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF6L 112320 SPS08F3PEF6L 152820 SPS08F4PMF6L 136550 SPS08F4PEF6L 177050
1000 SPS10F3PMF6L 118250 SPS10F3PEF6L 158750 SPS10F4PMF6L 146620 SPS10F4PEF6L 187120
1250 SPS12F3PMF6L 136340 SPS12F3PEF6L 176840 SPS12F4PMF6L 170100 SPS12F4PEF6L 210600
1600 SPS16F3PMF6L 157880 SPS16F3PEF6L 198380 SPS16F4PMF6L 194460 SPS16F4PEF6L 234960
Fixed Type circuit breaker with Microprocessor based ET2B Trip Unit
3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF2B 110520 SPS08F3PEF2B 151020 SPS08F4PMF2B 134750 SPS08F4PEF2B 175250
1000 SPS10F3PMF2B 116450 SPS10F3PEF2B 156950 SPS10F4PMF2B 144820 SPS10F4PEF2B 185320
1250 SPS12F3PMF2B 134540 SPS12F3PEF2B 175040 SPS12F4PMF2B 168300 SPS12F4PEF2B 208800
1600 SPS16F3PMF2B 156080 SPS16F3PEF2B 196580 SPS16F4PMF2B 192660 SPS16F4PEF2B 233160
Accessories
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 81
EasyPact TVS
The Easy choice for simplicity and flexibility
3 Pole and 4 Pole Power Contactor
z
Control Relays
z
Thermal Overload Relay
z
Circuit Breaker for Motor Protection
z
Accessories
z
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 82
EasyPact TVS
[Ie] Rated Operational Current Motor Power at 415V, 3Ph, 50Hz Auxiliary Contacts Unit MRP
Frame Reference
AC-1 AC-3 HP kW NO NC [`]
- 1 ,#%
¬;
20 6 3 2.2 895
1 - ,#%
¬;
- 1 ,#%
¬;
25 9 5.5 4 925
1 - ,#%
¬;
- 1 ,#%
¬;
FRAME-1 25 12 7.5 5.5 1050
1 - ,#%
¬;
- 1 ,#%
¬;
32 18 12 9 1210
1 - ,#%
¬;
- 1 ,#%
¬;
36 25 15 11 1655
1 - ,#%
¬;
- 1 ,#%
¬;
50 32 20 15 3465
1 - ,#%
¬;
- 1 ,#%
¬;
FRAME-2 50 38 25 18.5 4095
1 - ,#%
¬;
- 1 ,#%"
50 40 29 22 4370
1 - ,#%"
60 40 29 22 1 1 ,#%
¬; 5355
FRAME-3 70 50 34 25/30 1 1 ,#%
¬ 6510
80 65 50 37 1 1 ,#%
¬; 8820
[Ie] Rated Operational Current Motor Power at 415V, 3Ph, 50Hz Auxiliary Contacts
Frame Reference Unit LP [`]
AC-1 AC-3 HP kW NO NC
110 80 60 45 1 1 ,#%
¬; 11465
FRAME-4
120 95 60 45 1 1 ,#%
¬; 13755
150 120 75 55 1 1 ,#%
¬ 16380
FRAME-5
200 160 120 90 1 1 ,#%
¬ 21630
250 200 150 110 - - ,#%
¬ 29770
FRAME-6
300 250 175 132 - - ,#%
¬ 39230
320 300 215 160 - - ,#%
¬ 46965
FRAME-7
500 400 295 220 - - LC1E400
59705
FRAME-8 700 500 375 280 - - LC1E500
84095
FRAME-9 1000 630 500 375 - - LC1E630
¬ 119385
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
LC1E06…E25 ,!%8
860 LC1E120..LC1E300 B5 F5 M5 N5
LC1E32/E38/E40B ,!%8
1060 LC1E400..LC1E630 B7 F7 M7 N7
LC1E40/E65 ,!%8
LC1E80/E95 ,!%8
1965 Non Standard Voltage/code: 48V AC/E5, 380V AC/Q5, 440V AC/R5
LC1E120/E160 ,!%8
2185 Please add ` 120/- while ordering Contactors with Non-standard Voltages.
LC1E200/E250 ,!%8
3055
LC1E300 ,!%8
3330
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
¬&OR¬MORE¬INFORMATION¬CONTACT¬REGIONAL¬SALES¬OFlCE
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 83
EasyPact TVS
Power
Frame AC-1 Rating Reference Unit LP [`] Power Poles Reference Unit LP [`]
Poles
110 4NO L#%
). 10710 2NO + 2NC L#%
). 14910
FRAME-4
125 4NO L#%
12075 2NO + 2NC L#%
17850
3 1 C!%
970
2 2 C!%
¬
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
4 Pole Contactors
,#%
x¬,#%
,!%84
990
,#%
x¬,#%
,!%84
1185
,#%
x,#%
,!%84
2095
Control Contactors
#!%
,!%8
860
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
Note:
s 4P power contactor also available at 48V AC E7 and 380V AC Q7
s Add `120 while ordering non-standard voltages
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 84
EasyPact TVS
1NO+1NC LAEN11 ;
LC1E06.....E630 - 3Pole contactors 265
2NO LAEN20 ;
LC1E0600.....LC1E9500 - 4Pole contactors
Auxiliary contact block 2NC LAEN02 ; 315
CAE Control Relays
(Refer Accessory compatibility Tables) FRONT 2NO+2NC LAEN22 ;
485
4NO LAEN40 ;
SD starters to be built with Electronic
Star delta timer MSMI06 1870
timers
Changeover timer LC1E25..E630 LAETSD ; 2205
&OR¬HIGHER¬RATING¬CONTACTORS¬CONTACT¬NEAREST¬SALES¬OFFICE
2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE
Built in
Contactor -"&/tt -"&3$t LAEM Contactor -"&/tt LAEM -"&3$t
contacts
LC1E06 LC1E06
LC1E09 LC1E09
1
LC1E12
LC1E12
LC1E18
1NO or 1NC LC1E18
LC1E25
LC1E25
LC1E32
LC1E32 1 1
LC1E38 1 1
LC1E38
LC1E40B
LC1E40
LC1E40
LC1E50
LC1E50 1
LC1E65
LC1E65 1
LC1E80
LC1E80 1NO + 1NC
LC1E95
LC1E95
LC1E120
LC1E160 Control Relay Accessories Compatibility
LC1E200
LC1E250 Control Relay LAEN* LAERC
–
LC1E300
- 2
LC1E400 1 of
LC1E500 LAEN11 or
LC1E630 CAE LAEN20 or 1
LAEN02 or
LAEN22
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 85
EasyPact TVS
Unit MRP
Thermal Protection Adjustment Range For Use with Contactor Reference
[`]
LRE
0.1...0.16 E06...E38 LRE01
0.16...0.25 E06...E38 LRE02
0.25...0.4 E06...E38 LRE03
0.4...0.63 E06...E38 LRE04
0.63...1 E06...E38 LRE05 ;
1...1.6 E06...E38 LRE06 ;
1500
1.6...2.5 E06...E38 LRE07 ;
2.5...4 E06...E38 LRE08 ;
4...6 E06...E38 LRE10 ;
5.5...8 E09...E38 LRE12 ;
7...10 E09...E38 LRE14 ;
9...13 E12...E38 LRE16 ;
12...18 E18...E38 LRE21 ; 1660
16...24 E25...E38 LRE22 ; 1925
23...32 E25...E38 LRE32 ; 2570
30...38 E38 LRE35 ; 2890
17...25 E40...E95 LRE322
23...32 E40...E95 LRE353
3265
30...40 E40...E95 LRE355
37...50 E50...E95 LRE357 ;
48...65 E65...E95 LRE359 4280
Thermal Protection Adjustment Range For Use with Contactor Reference Unit LP [`]
LRE
55...70 E80...E95 LRE361 4975
63...80 E80...E95 LRE363
5085
80...104 E95 LRE365
51...81 E120...E300 LRE480
62...99 E120...E300 LRE481
84...135 E120...E300 LRE482
9525
124...198 E160...E300 LRE483
146...234 E200...E300 LRE484
174...279 E250...E300 LRE485
208...333 E300 LRE486 10380
258…414 E300…E400 LRE487 12625
321…513 E500 LRE488 13695
394…630 E630 LRE489 14765
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 86
EasyPact TVS
Breaking
Motor Power AC-3** Thermal Protection
Capacity at Unit MRP
Adjustment Range Reference
415 V [`]
(A)
50 Hz kW HP
- - 0.1 - 0.16 GZ1E01
0.06 - 0.16 - 0.25 GZ1E02 2700
0.09 - 0.25 - 0.40 GZ1E03
0.18 - 0.40 - 0.63 GZ1E04
3145
0.37 0.5 0.63 – 1.0 GZ1E05
100 kA
0.55 0.75 1.0 – 1.6 GZ1E06
3080
0.75 1 1.6 – 2.5 GZ1E07
1.1 2 2.5 – 4 GZ1E08
3200
2.2 3 4 – 6.3 GZ1E10
3 5.5 6 – 10 GZ1E14 3415
5.5 7.5 9 – 14 GZ1E16 3850
7.5 10 13 – 18 GZ1E20 4185
10 kA 9 12.5 17 – 23 GZ1E21 4410
11 15 20 – 25 GZ1E22 4630
15 20 24 – 32 GZ1E32 8265
Electric Trips
110…115V 50Hz GZ1AU115
Undervoltage 220…240V 50Hz GZ1AU225
RH Side Mounted 380…400V 50Hz GZ1AU385 1800
110…115V 50Hz GZ1AS115
Shunt trip
220…240V 50Hz GZ1AS225
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 87
Start smart, run smart,
stay smart with TeSys
se.com/in/TeSys
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 88
TeSys Range
Switch Disconnectors
Protection
Circuit Breakers
TeSys GV Circuit Breakers
Magnetic Thermal-magnetic
Control
Contactors
From 6A to 2750A Low Consumption versions
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 89
TeSys Range
Monitor
Vario
ComPact starter
Enclosed
DOL starters with manual control Starters For DOL starters and
safety applications
Specific Applications
For protection
Thermistor Advanced Motor Electromechanic Transformers Single pole Fuse solution
Protection unit Protection relay overcurrent relay and high magnetic over
current peak current relay
For control
For wind turbine For very small For capacitors For modular enclosures / Din rail
UPS panels machines
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 90
Machine builders, it is time to cut engineering
time and costs — DIGITIZE load management
TeSys island
Unique features
TeSys island is a smart, digital multifunctional load management system; it can switch,
protect, manage motors and other electrical loads up to 80 Amps (AC3) in
an electrical control panel.
Benefits
Why should you choose TeSys island?
s¬1UICKER¬ENGINEERING¬AND¬REDUCE¬TIME¬TO¬MARKET
s¬%MBEDDED¬ALGORITHMS¬DETECT¬ABNORMAL¬LOAD¬BEHAVIORS¬AND¬GENERATE¬ALARMS¬BEFORE¬
machine stoppage.
s¬0RE
TRIP¬WARNINGS¬CAN¬ALSO¬BE¬SET¬ON¬THE¬SYSTEM¬FOR¬SCHEDULED¬MAINTENANCE
s¬&AST¬DEVICE¬REPLACEMENT¬ON¬ANY¬PORTION¬OF ¬THE¬ISLAND¬IS¬POSSIBLE¬BECAUSE¬OF ¬THE¬FULL¬
integration of the system and the integrated Bus coupler resulting in reduced downtime.
s¬4E3YS¬ISLAND¬PROVIDES¬ENERGY¬MONITORING¬AT¬THE¬LOAD¬LEVEL
s¬(EALTH¬STATUS¬CAN¬BE¬EASILY¬ACCESSED¬REMOTELY¬OR¬LOCALLY¬4HIS¬ENERGY¬MANAGEMENT¬
data can be used for advanced analytics to increase machine effi ciency further
s¬4E3YS¬ISLAND¬CAN¬BE¬EASILY¬INTEGRATED¬INTO¬3CHNEIDER¬%LECTRICS¬%CO3TRUXURE¬-ACHINE¬
architecture and 3rd party automation systems, supporting all major fi eldbuses.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMALse.com/in/TeSys
STOCK ITEMS W.E.F. January 27, 2020
se.com/in 91
TeSys Range
Technical specifications
s¬3YSTEM¬CONSISTS¬OF ¬$/,¬3TARTERS¬¬)NPUT¬¬ s¬/NLY¬¬COMMERCIAL¬REFERENCES¬FOR¬THE¬
Output modules complete system, including 5 standard
s¬3YSTEM¬MANAGES¬MOTORS¬AND¬OTHER¬ motor starters and 5 functional safety motor
electrical loads up to 80A/37kW/50hp starters
s¬5P¬TO¬¬MODULES¬¬¬METER¬AT¬ONE¬BUS¬ s¬#YBERSECURITY¬EMBEDDED¬INTO¬THE¬SYSTEM¬
coupler (Achilles Level 2 & Safety up to Cat 2)
s¬.O¬MECHANICAL¬ADJUSTMENTSSETTINGS¬ s¬3AFETY¬STOP¬456¬CERTIlED¬3TOP¬¬AND¬¬WITH¬
required wiring categories 1 to 2, suitable for PL c,d
(Performance Level) and SIL level 2)
s¬)NTERNATIONAL¬STANDARDS
COMPLIANT
s¬/PEN¬CONNECTIVITY¬THANKS¬TO¬%THERNET¬)0¬AND¬
s¬%NERGY¬MONITORING¬AT¬THE¬LOAD¬LEVEL
Modbus TCP fieldbuses
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 92
TeSys Control Range
TeSys Rated opeartional AC-3 Duty Aux AC control Unit MRP DC Control Unit MRP
Frame Size
Control Range current AC-1 kW HP A Contacts Reference [`] Reference [`]
- 3 - 6 1NO/NC LC1K06
1050 LP1K06
1575
- 5.5 - 9 1NO/NC LC1K09
1115 LP1K09
1735
TeSys K FRAME-1
- 7.5 - 12 1NO/NC LC1K12
1220 LP1K12
1945
- 10 - 16 1NO/NC LC1K16
1460 - -
FRAME-2 32 9 12.5 18 1NO + 1NC L#$
1700 L#$
2900
40 11 15 25 1NO + 1NC L#$
2110 L#$
3800
FRAME-3 50 15 20 32 1NO + 1NC L#$
4180 L#$
7760
50 18.5 25 38 1NO + 1NC L#$
6010 L#$
9100
60 22 30 40 1NO + 1NC L#$!
6375 LC1D40A# 10975
80 25 35 50 1NO + 1NC L#$!
7995 LC1D50A# 13065
TeSys D FRAME-4
80 37 50 65 1NO + 1NC L#$!
11130 LC1D65A# 14630
80 37 50 80 1NO + 1NC L#$!
13650 LC1D80A# 17765
125 45 60 80 1NO + 1NC L#$
16500 LC1D80
18705
125 45 60 95 1NO + 1NC L#$
17090 L#$
21000
FRAME-5
250 59 80 115 1NO + 1NC L#$
21100 L#$
21895
250 80 110 150 1NO + 1NC L#$
27430 L#$
28425
Type Voltage 24V DC Low 24-60V AC/DC 48-130V AC/DC 100-250V AC/DC
consumption
TeSys D Green# LC1D40A-80A BBE BNE EHE KUE
Note: For ordering contactors with other coil voltages & frequencies, please add ` 190/- to the unit Price of the standard
contactor of the same rating.
How to ensure
reliablity of contacts?
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 93
TeSys K
C!+.
1680 C!+.
2050
4NO C!+.
C!+.
[Ie] Rated
Motor Power Auxiliary AC Control DC Control
Operational Unit LP [`] Unit LP [`]
(kW) Contacts Reference Reference(5)
Current (A)
1NC L#+
L0+
6 3 1050 1575
1NO L#+
L0+
1NC L#+
L0+
1NC L#+
L0+
1NC L#+
- -
16 10 1460
1NO L#+
- -
(5) For low consumption offer, please contact regional sales office
6 3 3390
1NO L#+
1NC L#+
9 5.5 3620
1NO L#+
1NC L#+
12 7.5 3725
1NO L#+
1NC L#+
16 10 4160
1NO L#+
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
(6) For current rating and ref please contact Customer Care
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 94
TeSys K
Accessories - K Model
¬,OT¬SIZE¬
(1) Front mounted with common point changeover contact
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 95
TeSys D
AC Control Unit MRP DC Control Unit MRP DC low consumption Unit MRP
No of Poles
Reference [`] Reference (2) [`] Reference (1) (2) (3) [`]
3NO + 2NC C!$
C!$
C!$
C!$
[Ie] Rated AC-3 Duty Auxiliary AC Control Unit MRP DC Control Unit MRP
Operational
kW HP A Contacts Reference [`] Reference (1) [`]
Current AC-1
4 5.5 9 1NO + 1NC ,#$
¬; 1305 ,#$
¬; 2100
25
5.5 7.5 12 1NO + 1NC ,#$
¬; 1470 ,#$
¬; 2350
32 9 12.5 18 1NO + 1NC ,#$
¬; 1700 ,#$
¬; 2900
40 11 15 25 1NO + 1NC ,#$
¬; 2110 ,#$
¬; 3800
15 20 32 1NO + 1NC ,#$
¬; 4180 ,#$
¬; 7760
50
18.5 25 38 1NO + 1NC ,#$
¬; 6010 ,#$
¬; 9100
60 22 30 40 1NO + 1NC L#$!
; 6375 LC1D40A# 10975
80 25 35 50 1NO + 1NC L#$!
; 7995 LC1D50A# 13065
80 37 50 65 1NO + 1NC L#$!
; 11130 LC1D65A# 14630
80 37 50 80 1NO + 1NC L#$!
; 13650 LC1D80A# 17765
45 60 80 1NO + 1NC ,#$
¬; 16500 ,#$
¬ 18705
125
45 60 95 1NO + 1NC ,#$
¬ 17090 ,#$
¬ 21000
59 80 115 1NO + 1NC ,#$
21100 L#$
21895
250
80 110 150 1NO + 1NC ,#$
¬; 27430 L#$
28425
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 96
TeSys D
¬; 2245
25
5.5 7.5 12 1NO + 1NC ,#$
¬; 2520
32 9 12.5 18 1NO + 1NC ,#$
¬; 3835
40 11 15 25 1NO + 1NC ,#$
¬; 4725
50 15 20 32 1NO + 1NC ,#$
¬; 8035
[Ie] Rated Motor Power AC-3
auxiliary Unit LP
Operational Reference
kW HP A contacts [`]
Current AC-1
60 22 30 40 1NO + 1NC LC1D40A# 10975
80 25 35 50 1NO + 1NC LC1D50A# 13065
80 37 50 65 1NO + 1NC LC1D65A# 14630
80 37 50 80 1NO + 1NC LC1D80A# 17765
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
¬ 2415
20
2NO + 2NC - - ,#$
¬ 2625
4NO - - ,#$4
2890
25
2NO + 2NC - - ,#$
3780
4NO - - ,#$4
¬ 3180
32
2NO + 2NC - - ,#$
4305
4NO - - ,#$4
4990
40
2NO + 2NC - - ,#$
6575
4NO - - LC1DT60A# 9985
60
2NO + 2NC - - ,0$
¬ 13125
[Ie] Rated AC control DC control
Poles Composotion Unit LP [`] Unit LP [`]
Operational Current AC-1 Reference Reference
4NO - - LC1DT80A# 14900
80
2NO + 2NC - - ,0$
17640
4NO - - ,0$
19110
125
2NO + 2NC - - ,0$
22050
250 4NO ,#$
24745 ,#$
26765
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
LC1D1150046 50/60 Hz F7 M7 N7
CAD, LC1D09-D38, LC1D80-D150 BD FD MD
D#
LC1DT20-DT40, LC1D098-D258, BD FD MD
LP1D40-D80, LC1D115
DC Low CAD BL FL ML
#ONSUMPTION
LC1D09-D32 BL EL SL
Type Voltage 24V DC Low consumption 24-60V AC/DC 48-130V AC/DC 100-250V AC/DC
TeSys D Green# LC1D40A-80A, LC1DT60A-DT80A BBE BNE EHE KUE
Note: Please contact Customer Care for 4 Pole AC coil contactor details
For ordering contactors with other coil voltages & frequencies, please add ` 190/- to the unit price of the standard contactor of the same rating.
(1) For current rating and ref please contact Customer Care
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 97
TeSys D Green
The Revolutionary Electronic Coil Contactor
New
80A AC3
offer available
in 55mm frame
se.com/in 98
TeSys D
LC1D09 - D38,
!#$#
LC1D40A - 80A, BNE EHE KUE
LC1DT60A - 80A
LC1D40A - 80A,
6¬$#¬,OW¬#ONSUMPTION
BBE (24V DC only)
LC1DT60A - 80A
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 99
TeSys D
¬¬'6,
.OT¬APPLICABLE¬FOR¬'60'6,¬!¬AND¬!
GV1G09
Description For use with Reference Unit LP [`]
LC1D09 to D38(1) LAD9V2 550
Mechanical interlock
LC1D40A to D65A(1) LAD4CM 1120
LC1D80 and D95 ( for AC control voltage) LA9D4002 2445
LC1D80 and D95 (for DC control voltage)(2) LA9D8002 3645
LC1D115 and D150(2) LA9D11502 3695
(1) With this set of busbars, any one contactor can be supplied directly by its EverLink® double cage power terminal block.
The other two contactors are supplied by the busbar set. The 115A limitation is therefore applied to these two contactors.
(2) With electrical interlock
GV3S
LA9 D8069
Description For use with Reference Unit LP [`]
Reversing Kit
Kit Comprising :
1. A mechanical interlock LAD 9V2 with electrical interlocking LAD 9V1 LC1D09 to D38 LAD9R1V 1140
2. A set of power connections LAD 9V5 (parallel) and LAD 9V6 (reversing).
Kit Comprising :
1. A mechanical interlock LAD 9V2 without electrical interlocking LC1D09 to D38 LAD9R1 905
2. A set of power connections LAD 9V5 (parallel) and LAD 9V6 (reversing).
Kit Comprising :
1. A mechanical interlock LAD 4CM LC1D40A to D80A LAD9R3 2715
LAD9R1
2. A set of power connections LA9 D65A69.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 100
TeSys D
AC Coils
CAD, LC1-D09...D38, DT20..40 ,8$
920
LC1D40A, D50A, D65A & LC1DT60A, DT80A ,8$
2480
D80 & D95 (3P & 4P) ,8$
2990
LC1-D115,D150 ,8$
5055
DC Coils
LC1-D80-D95 ,8$
7780
LC1-D115, D150 ,8$
8555
Note: For ordering coils with other voltages and frequencies, please add ` 190/- to the unit price of the respective standard coil.
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 101
TeSys D
Accessories - D Model
Add On Blocks
Additional instantaneous auxiliary Side 1NO + 1NC LAD8N11
1120
contact blocks Mounted (1) 2NO LAD8N20
1NO + 1NC 0.1..3s LADT0
1NO + 1NC 0.1..30s LADT2 2655
ON delay
Pneumatic 1NO + 1NC 10..180s LADT4
timer blocks 1NO + 1NC 1..30s (2) LADS2 ; 2830
front mounted 1NO + 1NC 0.1 ..3s LADR0
OFF delay 1NO + 1NC 0.1 ..30s LADR2 ; 2655
1NO + 1NC 10..180s LADR4
Set of shins to be used with 4 pole contactors LA9D511 1080
(1) Suitable for mounting on D Model range AC Coil Contactors and Control Relays only
(2) With Switching time of 40 ms between opening of the NC contact and closing of the NO contact recommended for Star - Delta Starters
Accessories compatibility
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 102
TeSys D
Control Circuit
Product Compatibility Fixing Suppressor Type Reference Unit LP [`]
Voltage
Coil Suppressor Modules
LC1D12...D25 (4P) 24...48V AC RC Circuit AC LA4DA1E
LC1D12...D25 (4P) 110...240V AC RC Circuit AC LA4DA1U
LC1D12 & D25 (4P) 12...250V DC Diode DC LA4DC1U 1020
LC1D12...D25 (4P) 24...48V AC/DC Varistor AC/DC LA4DE1E
- 110...250V AC/DC Varistor AC/DC LA4DE1U
Clip-on
24...48V AC Varistor AC/DC LAD4VE
LC1D09...D38, LC2D09...D38, 985
24...48V AC 400Hz RC Circuit AC LAD4RCE
LC1DT20...DT40, LC2DT20...DT40 (3P)
50...127V AC 200Hz RC Circuit AC LAD4RCG
110...240V AC 100Hz RC Circuit AC LAD4RCU ; 895
CAD
110...250V AC Varistor AC/DC LAD4VU
LC1D80, LC1D95, LC2D80, LC2D95 (3P)
24...250V DC Diode DC LA4DC3U 1020
LC2D80 (4P), LC1D40008, LC1D65008
24...48V AC Varistor AC/DC LA4DE2E
110...250V AC Varistor AC/DC LA4DE2U 975
24...48V AC 400Hz RC Circuit AC LA4DA2E
Screw
LC1D80...D115, LC2D80...D115 (3P) 50...127V AC 200Hz RC Circuit AC LA4DA2G 1540
LC1D80...D115, LC2D80...D115 (4P) 110...240V AC 100Hz RC Circuit AC LA4DA2U 1020
380...415V AC 150Hz RC Circuit AC LA4DA2N 1540
24...48V DC Varistor AC/DC LA4DE3E 1020
110...250V DC Varistor AC/DC LA4DE3U 975
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 103
TeSys D
Safety covers
and auxiliary blocks
prevent screwdriver
Standard TeSys U motor starters contact with poles
Built in Safety
TeSys U motor starters are certified according to IEC 60947-4-1 for safety applicarions thanks to integrated mirror contact
Auxiliary Contact Block With red front face - for safety chain
2NO + 2NC LADN22S 755
indication
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 104
A perfect fit for
power switching
s¬0ROVEN¬RELIABILITY¬¬HIGH¬ELECTRICAL¬DURABILITY
s¬7IDE¬OPERATING¬TEMPERATURE¬RANGE¬UP¬TO¬¬DEG¬#
s¬4YPE¬¬¬¬#O
ORDINATION¬WITH¬-ASTER0ACT©¬!#"
s¬3HARED¬ACCESSORIES¬WITH¬ENTIRE¬4E3YS¬&¬RANGE
s¬$RAWER
MOUNTED¬COILS¬ALLOW¬EASY¬MAINTENANCE
Introducing the specially
designed LC1SF1200* Contactor
for solar PV applications
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMALse.com/in/TeSys
STOCK ITEMS W.E.F. January 27, 2020
se.com/in 105
TeSys F
[Ie] Rated Operational Current AC-1 Power Pole Composition Reference Unit LP [`]
1250 LC1F1250
1700 LC1F1700
on Request
2100 LC1F2100(1)
2600 LC1F2600(2)
(1) With set of right-angled connectors LA9 F2100
(2) With set of right-angled connectors LA9 F2600
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 106
TeSys F
Coils F Model
Product compatibility AC Coil Reference Unit LP [`] DC Coil Reference (2) Unit LP [`]
7395
LC1F185, LC1F225 ,8&'
4840 ,8&'
9845
LC1F265, LC1F330 ,8&(
6020 ,8&(
11985
LC1F400 ,8&*
12400 ,8&*
18975
LC1F500 ,8&+
14750 ,8&+
19585
LC1F630 ,8&,
16500 ,8&,
20300
LC1F780 ,8&8
¬(3) 40755 ,8&8
(3) 25000
LC1F800 (1)
- ,8&
28920
LC1F1000, LC1F1700, LC1F2100 ,8&+
(3) 14750
LC1F2600 ,8&,
(3) 16500
Please replace ( * ) with the Corresponding Control Voltage.
(1) Use rectifier with required DC coil (Ref: DR5TE4U)
(2) Coil with suppressor fitted as standard.
(3) Set of two coils to be connected in series.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 107
TeSys F
110V 220V
Description For use with Unit LP [`]
Reference Reference
Suppressor Blocks
suppressor module clip on All AC ratings LA4FRCF LA4FRCP 4915
suppressor bracket For all LA4F LA9D09981 515
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 108
TeSys Special Purpose Contactor
Unit MRP
Nominal Reactive Power 440V Auxiliary Contacts Reference
[`]
LC1-DK - with Damping Resistors & Block of Early Make poles
12.5 kVar 1NO + 2NC ,#$&+
2935
16.7 kVar 1NO + 2NC ,#$'+
4120
20 kVar 1NO + 2NC ,#$,+
4630
25 kVar 1NO + 2NC ,#$-+
5080
33.3 kVar 1 NO + 2NC ,#$0+
11060
40 kVar 1NO + 2NC ,#$4+
15240
60 kVar 1NO + 2NC ,#$7+
17155
#Contactor recommended upto 6 steps. For over 6 steps it is recommended to use chokes
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
Note: For ordering contactors with other coil voltages & frequencies, please add ` 190/- to the
unit price of the standard contactor of the same rating.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 109
TeSys Special Purpose Contactor
Bar contactors
General Purpose offer
LC1B Range for standard applications
z From 750A to 1800A AC-3
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 110
TeSys H - Ultra-ComPact starters
22.5 mm
Up to 75 %
of space reduction
Ultra-compact 22.5 mm starter
PB114721_R.eps
Long electrical
durability
Suitable for high demanding
application
Easy Easy
Design to integrate
Wide range setting motor Direct mounting installation
protection on DIN rail
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 111
TeSys H - Ultra-ComPact starters
Standard version
kW 1 way (DOL)
0.75 0.18…2.4A ,:(8
¬ On Request ,:(8
¬ On Request
3 1.5…6.5A ,:(8
¬ On Request ,:(8
¬ On Request
2 ways (RDOL)
0.75 0.18…2.4A ,:(8
¬ On Request ,:(8
¬ On Request
3 1.5…6.5A ,:(8
¬ On Request ,:(8
¬ On Request
PB114721_r.eps
PB114721_r.eps
PB114721_r.eps
PB114722_r.eps
GV2L + LZ2H2X4BD
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 112
TeSys Protection Range
TeSys has the most rugged and reliable solution to manage motors
Please find a quick range overview below
GV2ME GV4PEM LR9D LR9F EOCR SSD TeSys U EOCR TeSys Island
Short circuit
Causes of
overheating
z Slight overload
z Locked rotor
z Abnormal temperature
With probes
rise
z Insulation fault
z Severe duty
z Voltage variation
Causes of phase
variation
z Phase reversal LR9D only
z Phase losses
z Phase imbalance
Mechanical shocks
Historic fault,
prealarming
Possible Pre-alarm
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 113
Overload
A perfect relays
fit for for
Motor
powerSafety
switching
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL se.com/in/TeSys
STOCK ITEMS W.E.F. January 27, 2020
se.com/in 114
TeSys LRD
Thermal Protection Reference* Unit MRP Thermal Protection Adjustment Range Reference Unit LP [`]
For Use With
Adjustment Range [`] LR9-F Electronic Protection Relays
LRD Model (Direct Mounting) 30...50 LR9F5357
0.1...0.16 LRD01 48...80 LR9F5363 11000
0.16...0.25 LRD02 60...100 LR9F5367
0.25...0.4 LRD03 90...150 LR9F5369 ; 11235
0.4...0.63 LRD04 132...220 LR9F5371 13160
0.63...1 LRD05 ; 200...330 LR9F7375 14125
1745
1...1.6 GV2L03, LE03, LRD06 ;
300...500 LR9F7379 17335
1.6...2.5 LC1D09...LC1D38 LRD07 ;
380...630 LR9F7381 18405
2.5...4 LRD08 ;
4...6 LRD10 ;
5.5...8 LRD12 ;
7...10 LRD14 ;
1960
9...13 LRD16 ;
12...18 LRD21 ;
GV2L22, 2020
16...24 LRD22 ;
LC1D25...D38
LC1D25...LC1D38,
23...32 LRD32 ;
LC1D32 3240
30...38 LC1D32, LC1D38 LRD35
LC1D40A...D65A LRD332
23...32
LC1D80...LC1D95 LRD3353
30...40 LC1D40A...D65A LRD340 3585
30...40 LC1D80...LC1D95 LRD3355 Note:
LC1D40A...D65A LRD350 ; 4920 s¬For LRD01...LRD35 - Terminal Block for clip-on Mounting LAD7B106
37...50
LC1D80...LC1D95 LRD3357 5885 s¬&OR¬,2$
¬
¬4ERMINAL¬"LOCK¬FOR¬CLIP
ON¬-OUNTING¬,!$¬;
48...65 LC1D40A...D65A LRD365 6315 s¬For LRD332, LRD340, LRD350 & LRD365 - Connection block for separate
62…80 LC1D80A LRD380 6580 mounting LAD96560
48...65 LC1D80...LC1D95 LRD3359 6315 s¬The LRD relays can be used for AC or DC current up to 104A
63...80 LC1D80...LC1D95 LRD3363 6850 s¬For long starting, Class 20 relays are available on request.
80...104 LC1D80, LC1D95 LRD3365 8455 s¬Device for remote tripping and electrical reset is available on request.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 115
Advanced
Motor Protection
High performance protection
for your application
EOLR EOCR
Electronic Overload Relay Electronic Over Current Relay
z Precise Overload Protection z ComPact and Robust
z Wide operating Range 5:1 z Advanced current protections
z Higher Operating Temperature z Suitable for 1-phase and 3-phase applications
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL se.com/in/TeSys
STOCK ITEMS W.E.F. January 27, 2020
se.com/in 116
EOLR - LR9D
EOLR EOCR
3MZ2/
SS/ 3DM2/ FMZ2/
Features\product LR9D
SSD FDM2 3BZ2/
FBZ2
Precise Overload Protection (Inverse Time)
tConformance to IEC, UL, CSA Over Current Protection (Defnite Time)
tRange : 0.1A to 32A Selectable Trip Clas 5-30
t5:1 Adjustment range
Current Unbalance Protection
tHigh Operating Temperature
Locked Rotor, Phase Loss
Analog EOCR
tComPact
tProtection against over current/phase loss/locked rotor (phase
loss/locked rotor operates by over current)
tManual (instant)/electrical reset
tNVR (No Volt Release) function / Fail Safe
tSuitable for single-phase / 3-phase motors
tLED (operation display and active current display)
5 0.5-6A For 60A or higher, combine 05Type 5 0.5-6A For 60A or higher, combine 05Type
Current Setting Current Setting
1 30 3.0-30A and an external CT (secondary 5A) 1 30 3.0-30A and an external CT (secondary 5A)
Range Range
60 5.0-60A for use 60 5.0-60A for use
2
Operating Pow- S 24-240V AC/DC 2
Operating Pow- S 24-240V AC/DC
er Supply W 380-440V AC er Supply W 380-440V AC
Note: For a CT combination type, please write an accessory code from Note: For a CT combination type, please write an accessory code from
the CT Order Codes separately. the CT Order Codes separately.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 117
Digital EOCR NEW
Current Control
Reference Description Unit MRP [`]
3 D M 2 - W R D U W Z Range Voltage
1 2 3 4 5 6
3DM2-WRDUWZ
14750
3DM2-WRDUHZ Without ground - fault
3DM2/
Digital Without Ground Fault Protection FDM2-WRDUWZ protection
FDM2 15950
Electronic FDM2-WRDUHZ
3MZ2/ With Ground Fault Protection with 3MZ2-WRAUWZ
1 Over-
FMZ2 External ZCT
current 3MZ2-WRAUHZ
Relay 3BZ2/ With Ground Fault Protection inbuilt 3MZ2-WRCUWZ
FBZ2 ZCT 14950
3MZ2-WRCUHZ
Built-in display 3zz2 Flush mounting display Fzz2 3MZ2-WRDUWZ
100-240V 3MZ2-WRDUHZ With ground - fault
No Item Type Current Range 0.5-80A
AC/DC FMZ2-WRAUWZ protection
2 Standard WR 0.5...80A FMZ2-WRAUHZ
b (95-96), a(97-98), a(07-08)
D FMZ2-WRCUWZ
3DM2, FDM2 17950
3 Relay Output A a(97-98): OL, a(57-58): GF FMZ2-WRCUHZ
3MZ2,
C b(95-96), a(97-98): OL/GF FMZ2-WRDUWZ
FMZ2
D B
¬¬/,¬A
¬'&
FMZ2-WRDUHZ
B AC/DC 24V
4 Control Power 3BZ2-WRAUHZ
U AC/DC 100~240V With ground - fault 21700
W 7INDOW
HOLE¬TYPE
3BZ2-WRCUHZ
5 Wiring Method protection (inbuilt
H Bottom-hole type FBZ2-WRAUHZ
ZCT) 22050
6 Version Z New version FBZ2-WRCUHZ
* Not Possible with 3BZ2/FBZ2
EOCR Accessories
ZCT - Ground Fault Protection Current Transformer
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 118
Introducing
New TeSys GV4
Circuit breaker for Motor protection
motor controllers
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL se.com/in/TeSys
STOCK ITEMS W.E.F. January 27, 2020
se.com/in 119
Circuit Breakers for Motor Protection
¬(Z¬
¬6
75 101 70…150 GV5P150H 30000
GV2-L with the D Model contactor and LRD overload relay provides
Type 2 Co-ordination 110 147 100...220 GV5P220H 35000
70KA
160 214 160...320 GV6P320H 45000
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 120
MCCB for Motor Protection
GV4LE
tIEC/EN 60947-1, IEC/EN 60947-2, CCC, EAC
tCan be used with class 5, 10 or 20 relay
t3HORT¬#IRCUIT¬0ROTECTION¬WITH¬AN¬ADJUSTABLE¬PICK
UP¬)I¬¬¬TO¬¬)N
tFrom 0.25 - 55kW
GV4PE
tIEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60497-4-1, CCC,
EAC, CSA
tOverload or thermal protection
tShort time delay protection
tShort circuit protection
tFixed Ground fault protection
tPhase unbalance or phase loss
tFront indications through LED
tVariable Trip class : Trip Class 10/ Trip Class 20
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 121
Accessories for GV4
MX Shunt Trip
t Trips the circuit breaker when the control voltage rises above 70% of rated
voltage
t Shunt trip 110..130V AC is suitable.. etc for ground fault protection when
combined with a Class I ground fault sensing element
Auxiliary Contact Block 2 (1 Each For OF or SD) Internal Plug-In NO + NC GV4AE11 800
Rotary Handles
Description Type Degree of Protection Reference Unit LP [`]
Black IP40 GV4ADN01
Direct Mounting Rotary Handle 1195
Red Handle on Yellow Bezel IP40 GV4ADN02
Black IP54 GV4APN01
Front Extended Rotary Handle (Min Shaft Length 1775
Red Handle on Yellow Bezel IP54 GV4APN02
214Mm/Max Shaft Length 627Mm)
Red Handle on Yellow Bezel IP65 GV4APN04 1865
Black IP54 LV426935 2800
Side Rotary Handle (Left or Right)
Red Handle on Yellow Bezel IP54 LV426936 2860
Connection Accessories
Description Reference Unit LP [`]
Spreader 3-pole (To increase pitch to 35mm) (1 pce) LV426940 600
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 122
Accessories
Accessories for Motor Circuit Breakers Accessories for Motor Circuit Breakers
Description Reference Unit LP [`] Description Reference Unit LP [`]
For GV2 For GV2-P/GV2-L
Front contact NO or NC (1) GVAE1 780 External operator - IP54, Black GV2APN01 ; 2750
GVAE11 ; 950 External operator - IP54, Yellow/Red GV2APN02 5060
Front contact NO + NC
GVAE20 1050 Visible isolation block - for motor circuit GV2AK00 2300
GVAN11 ; breaker GV2
Side contact NO + NC 1150
GVAN20 For GV3P/GV3L
Fault signalling contact + 1NO contact (2) GVAD1010 ; Auxiliary Contacts
1500
Fault signalling contact + 1NC contact (2) GVAD1001 Front contact: 1 NO (fault) + 1NC (Auxiliary) GVAED011 990
Short circuit signalling contact block 1 C/O GVAM11 1430 Front contact: 1 NO (fault) + 1NO (Auxiliary) GVAED101 1090
Under 110 ... 115V 50Hz GVAU115 2560 Busbar
voltage 220 ... 240V 50Hz GVAU225
3-pole, 3 tap, 64 mm pitch GV3G364 1150
trip 380 ... 400V 50Hz GVAU385
S-shape bus bar GV3S 865
110 ... 115V 50Hz GVAS115 2740
Shunt trip 220 ... 240V 50Hz GVAS225
External Operator
IP54, Black GV3APN01 3280
380 ... 400V 50Hz GVAS385
IP54, Yellow/Red GV3APN02 3150
Additive limiter for increasing breaking
GV1L3 4420 Note: All other accessories are same as of GV2.
capacity to100kA for GV2ME and GV2P.
connection block - GV2 with contactor "USBARS¬'6'¬AND¬'63¬ARE¬NOT¬COMPATIBLE¬WITH¬'6
¬AND¬'6
GV2AF3 540
LC1-D09..D38
Connection block - LS1 D32 or GV2 with Operating
GV2AF01 580 Description Reference Unit LP [`]
Contactor LC1-K or LP1-K Voltage
GV2MP02 2035
Empty enclosure for GV2ME - plastic For GV7
GV2MC02 2240
Accessory for direct
(1) Choice of NC or NO contact operation depending on which way round rotary handle mount on - GV7AP05 1860
the reversible block is mounted. door (2)
(2) The GV-AD is always mounted next to the circuit breaker.
Auxiliary contact - 1 OC - GV7AE11 ; 1830
Clip-on connector - upto
Busbars - GV7AC021 750
150 A - 1.5..95 mm2
No. of Clip-on connector- upto
Connection Pitch Reference Unit LP [`] - GV7AC022 710
Tapoff Points 220 A - 1.5..185 mm2
For GV2 Breakers 24...72V DC/
GV7AD111 5360
2 GV2G245 1200 Fault discrimination 24...48V AC
45 mm device 110 ... 240V AC/
4 GV2G445 1895 GV7AD112 5360
DC
2 GV2G254 1370
3 GV2G354 1540 Front rotary handle GV7AP03 3150
54 mm GV7AP GV7R - black -
4 GV2G454 1930 GV7AP01 5480
handle (2)
5 GV2G554 2090
Padlocking device - 1..3
2 GV2G272 1640 - GV7V01 840
72 mm padlocks Ø5..8mm shank (3)
4 GV2G472 2360
Phase barriers - GV7AC04 965
Terminal shields IP405 (1) - GV7AC01 1945
Description Reference Unit LP [`] For GV7
110...130V AC
Accessories for Busbars GV7AS107 4165
50/60Hz
Terminal block - to supply one or more
GV2G05 2960 200...240V AC
3-pole busbar GV2 Shunt release GV7AS207 4165
50/60Hz
Protective end covers for unused busbar
GV1G10 520 380...440V AC
outlets GV7AS387 4010
50/60Hz
Terminal block for connection from top GV1G09 1550
110...130V AC
GV7AU107 4300
50/60Hz
200...240V AC
Under Voltage release GV7AU207 4300
50/60Hz
380...440V AC
GV7AU387 4300
50/60Hz
3-pole spreader - for
motor circuit breaker GV7 GV7AC03 1245
45 mm pitch
(1) Terminal shields cannot be used together with spreaders.
(2) For mounting direct rotary handle on enclosure door.
This accessory makes it possible to open the door If the device is closed and
prevents the device from being closed if the door is open.
(3) For Circuit breaker not fitted with a rotary handle
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 123
TeSys
Accessories compatibility
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 124
TeSys
Accessories compatibility
GV3 G264
GV3 G364
GV AM11
GV3 P
GV AM11
GV3 L
GV AE11, GV AE20,
GV AED 101, GV AED 011
GV AE1
GV AE1
GV3 APN02
GV2 V03
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 125
TeSys GV4 Overview
k
in
rl
ve
E
m
m
link
0
2
Ever
1
GV4G
eredLin k logy
6
Event techno
Pat
5
7
SDx
ON
JAM
T UNB
1
TAM LS
Txxs GF
T95%
SDTAM
8 10
6 12
4 14
2 15
1 OFF
2
T JAMUNB
TAM LS
SDx
Txxs GF
T95%
9
MX
250V
~/=
10 25A
S li=17
CLAS L3
SD
>95%
ALARM
>XXA
20 L2
READY
t
4 6
Ir(A)2
8 L1
1 i
10
Ii
Ir Isd
14
15
12 MN
250V
OF
10 TeSys
11
5
9659
link LAD
Ever
With
d)
(Rigi
mm²
9
Cu
..70
5S 1 x 1,5.....95 Cu
EM11 1 x 1,5...
GV4P 8kV d)
Uimp
(Rigi
mm² Cu
..70
1 x 1,5.....95 Cu
Ui 800V
5A 1 x 1,5... e
In:11 g torqu
A) enin
Ics(k er tight
A)
Icu(k 120 Pow N.m
11
) 120 100
Ue(V 5
40 100 70
220/2 mm² 9
15 70 30
380/4 30 18 y10
440
500
525
18
10
2.5
40°C
O u16
90
690/6 Cat A
Hz
50/60 60947-2
N
IEC/E
s
TeSy 5S
EM11
t
se
GV4P
Re
Cat.A
50/60Hz
100
65
240V 14
480V
600Y/347
CB
.8
Ø 4..
LISTED
No:186
Issue
E10027
2
GB14048.
s
TeSy 5S
Trip
EM11
t
se
GV4P
15
Re
Cat.A
50/60Hz
100
ref.
65
240V 14
480V
Axial
600Y/347
4...8
.8
CB
Ø 4..
LISTED
Ø
No:186
Issue
E10027
2
GB14048.
Trip
s
TeSy 5S
EM11
GV4P
OFF
Cat.A
50/60Hz
100
65
240V 14
480V
600Y/347
CB
LISTED
No:186
Issue
E10027
s
TeSy 5S
EM11
t
se
2
GV4P
Re
GB14048.
12
Cat.A
50/60Hz
100
65
240V 14
480V
600Y/347
CB
LISTED
No:186
Issue
E10027
2
GB14048.
Trip
Ø
4...8
On
ip
Tr
On
.8
Ø 4..
ip
Off
Tr
et
Res
Ø
4..
.8
14
.8
Ø 4..
Off
et
Res
13
14
13
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 126
Linergy
Linergy BZ
Power Busbars
Quick Installation
Intuitive Solution
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 127
Linergy BZ
Linergy BZ, Multistandard power busbar system,
Application: power distribution to motor starters
systems
busbar
Power
Terminal plate,
for busbar supply connection Mounting plates
for motor starters,
Motor circuit breaker and contactor
Direct-On-Line or Reverse
assembly, equipped with mounting
plate and RJ45 connection module
(for control and command)
Advantages
Considerable space saving: components are directly mounted on the busbar
Large choice of mounting plates (for GV2, GV3 motor circuit breakers and assemblies, GV7, TeSys U)
Quick connection, deconnection (power off): clip-on mounting plates
Vibration resistant busbar connections: no periodical re-tightening required
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 128
Linergy HK
Linergy HK, Multistandard hot-plug busbar system,
Application: electrical distribution to motor starters
All-in-one TeSys U
motor starter on a
single mounting plate
Motor starter
assembly on a double
mounting plate
Motor circuit breakers mounted
on a separated DIN rail.
Advantages
• Space saving in compact enclosures: the total volume is reduced to that of the motor starter assemblies
• nce: live connection, disconnection (off load)
• Wide adaptability: 6 busbar lengths from 344 to 1100 mm, 12 models of sockets, 23 mounting plates
for motor starters up to 25 or 50 A
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 129
TeSys Switches
Accessories
For Use with Rating Pole Earth Auxiliary
Description Reference Unit LP [`]
switch Bodies in A Composition Contact contacts
Vario Add-on Modules (1)
V02/VCF02 12 1P - - VZ02 780
V0/1/VCF01 20 1P - - VZ01 800
V0/VCF0 25 1P - - VZ0 850
Main Pole Module V1/VCF1 32 1P - - VZ1 830
V2/VCF2 40 1P - - VZ2 890
V3/VCF3 63 1P - - VZ3
1155
V4/VCF4 80 1P - VZ4
V02 / VCF02 to V2 / VCF2 - 1N - - VZ11 950
Neutral Pole Module (2) V3 / VCF3 to V4 / VCF4 - 1N - - VZ12 1275
V5 / VCZ5 to V6 / VCZ6 - 1N - - VZ13 2635
V02 / VCF02 to V2 / VCF20 - - - - VZ14 940
Earthing Module V3 / VCF3 to V4 / VCF4 - - 1 - VZ15 1110
V5 / VCZ5 to V6 / VCZ6 - - 1 - VZ16 1725
Auxiliary Contact V02/ VCF02 to V6 / VCZ6 - - - 1NO + 1NC VZ7 980
Block Module V2/ VCF02 to V6 / VCZ6 - - - 2NO VZ20 980
(1) For mounting option of modules, please refer to the technical catalogue.
(2) With early make and late break contacts
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 130
TeSys Switches
Accessories
KA/ 1BZ
VN 12, VN 20 KC/ 1LZ
V02…V2
KC/ 1YZ
KD/ 1PZ
KA/ 1PZ
V3, V4
KC/ 1PZ
VZ 18, VZ 31
KAF 2PZ
KCF 2PZ
KZ 81
V5, V6
KBF 2PZ
VZ 18, VZ 31
KDF 2PZ
KZ 74
KBF 3PZ
KDF 3PZ
KAF 3PZ
KCF 3PZ
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 131
Let TeSys U
build the solution for you!
se.com/in 132
TeSys U - Make the Starter Smarter
Control Unit
Performs all the electrical protection functions
to cover main applications
from 0 to 32A.
Some of these also provide advanced meas-
urement, alarm and
40%
“TeSys solutions allow us to reduce
display functions.
the size of our enclosure”
says a panel builder from the water treatment
sector
4 simple function modules
Thermal overload alarm Indication of motor load
Thermal overload signalling and manual reset
Thermal overloaded signalling and automatic or
remote reset.
60%
“Late customization means that we
can build 60% of the panels, even
though the project design has not
Power Base 6 communication modules yet been completed”
For assembling components, AS-Interface says an engineer in a food processing
ON/OFF operation and resetting. Profibus DP industry
2 power bases: CANopen
upto 12A and upto 32A DeviceNet
Direct starter and Advantys STB
reversing starter models. Modbus.
Quick Selection
Select 1 + Select 1 Optional or Optional or Optional
3UITABLE¬WITH¬6¬$#¬STARTER¬VARIANT¬ONLY
Note: For prices please contact regional sales office or customer care centre
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 133
Wherever productivity
is a concern, intelligence
to Motor Control is the
solution
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 134
Tesys T Motor
Management Systems
TeSys T covers all load monitoring and protection needs from feeders to critical process automation. The equipment
is protected, while advanced diagnostics, statistics, and alarms help in anticipating unexpected production halts
and minimize downtime. TeSys T is ComPact and a natural fit for control panels with IEC or NEMA standards. In
addition, the system’s connectivity and access to real-time data provides key information to enhance the operation
and safety of the process while improving efficiency.
Tesys T Controller:
Intelligent motor controller for 1P/3P Motors with built in CT up to 100Amps with accurate monitoring and protection functions,
6DI, 4DO, 1CBCT input, 1 Temperature probe
z Temperature monitoring via probes z Motor temperature, ground current RDOL, Star-delta, two-speed starters
z Phase reversal z Active and Reactive Energy
z Ground fault detection zFrequency & Power Factor
Quick Selection
TeSys T Controller TeSys T Accessories
1
Required for Voltage & Power measurement
2
0.4 - 8 A 08 4 digital inputs
1.35 - 27 A 27
DeviceNet D 1 LTM9CEXP10
Ethernet IP / 3
E Sold in lots of 6
Modbus TCP/IP
Modbus M
Ground Fault CT’s Current Transformers4
Profibus DP P
Primary Internal Ø Reference Primary [A] Secondary [A] Reference
[A] “d” [mm]
100 1 LT6 CT1001
65 30 50437
Voltage
Control
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
Note: For prices please contact regional sales office or customer care centre
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 135
TE Start - Lifeline of Motors
se.com/in 136
TE Start & TeSys Motor Starters
tExhaustive Range of industrial starters consisting of DOL, Reversing, Automatic star delta starters
tBetter aesthetic & Assured performance
tTest to trip facility
tBuilt in single phasing protection
DOL Starters Star Delta Starters
Thermal Thermal
Motor Device Motor Device
Protection Unit MRP Protection Unit MRP
Power Short Reference Power Short Reference
adjustment [`] adjustment [`]
HP Name HP Name
Range Range
TDL, Automatic 1 Phase (0.17 - 3 HP) TSD/A, Automatic 3 Phase (7.5 - 400 HP)
7.5 5.5...8 15TSDA -3!)
16...24 5140 Note:- Submersible Star-Delta Starter Panel Starters are available on
15 15TDL -3!#
¬; request. Please consult our local Sales Office.
17.5 20TDL -3!#
3925
100 100TDL -3!#
39395
124...198 0.8...1.2 0.37 ,%-
4400
125 125TDL -3!#
48560
1.2...1.8 0.55 ,%-
4370
TRS, Automatic Reversing 3 Phase (3 - 20 HP) 1.8...2.6 0.75 ,%-
3 4...6 10TRS -32*
2.6...3.7 1.50 ,%-
4630
5 5.5...8 10TRS -32*
3.7...5.5 2.20 ,%-
7465
7.5 9...13 10TRS -32*
5.5...8 3 ,%-
4370
10 12...18 10TRS -32*
8...11.5 4 ,%-
4630
12.5 20TRS -32*
10...14 5.50 ,%-
4910
16...24 12215
15 20TRS -32*
12...16 7.50 ,%-
4630
17.5 20TRS -32*
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 137
Starters Spares
Spare Parts
Lot Unit MRP
Description Reference
Order Quantity [`]
For TDL, TRS & TSD/A Starters
Pushbutton Actuator Assembly for 10/40/50/75/100/125 TDL 10 MSMC02 235
Pushbutton Switch Assembly for 10 TDL 10 MSMC03 465
Start Pushbutton Assembly for
10 MSMI01
40 - 400 TSDA
305
Stop Pushbutton Assembly for
10 MSMI02
40 - 400 TSDA
9 Way Terminal Block for 15 TSDA 10 MSMl03
440
9 Way Terminal Block for 30 TSDA 10 MSMl04
9 Way Terminal Block for 40 - 75 TSDA 10 MSMl05 1060
Electronic Timer for 15 - 400 TSDA 10 MSMl06 1870
Pushbutton Actuator Assembly
for 15/20/30 TDL, 10 MSMK01 505
10/20 TRS &15/30 TSDA
Note:- For Spare coil, contactor, O/L relay and accessories, please contact nearest sales office
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 138
Type 2 Co-ordination chart
Type 2 co-ordination chart for Direct-On-Line starter with circuit breaker and overload
protection built into the circuit breaker
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
(1) The breaking performance of circuit-breakers GV2 P can be increased by adding a current limiter GV1 L3
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬REPLACING¬THE¬
¬WITH¬THE¬BREAKING¬PERFORMANCE¬CODE¬AS¬PER¬TABLE¬GIVEN¬BELOW
GV4PE/ GV4PE/
Circuit breaker type GV5P150* GV5P220* GV5P320* GV6P500*
PEM80* PEM115*
Breaking performance Iq (kA) at 400/415V 70 70 70 70 50 50
Breaking performance code H H H H N N
For advanced protection, protection with Electronic Overcurrent Relays, heavy starting, please contact our sales teams.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 139
Type 2 Co-ordination chart
Type 2 co-ordination chart for Direct-On-Line starter with circuit breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬REPLACING¬THE¬
¬WITH¬THE¬BREAKING¬PERFORMANCE¬CODE¬AS¬PER¬TABLE¬GIVEN¬BELOW
NSX160*MA, NSX400*
Circuit breaker type NSX100*MA GV4L/LE80* GV4L/LE115*
NSX250*MA NSX630*
Breaking performance Iq (kA) at 400/415V 50 50 50 50 50
Breaking performance code N N N N N
For advanced protection, protection with Electronic Overcurrent Relays, heavy starting, please contact our sales teams.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 140
Type 2 Co-ordination chart
Type 2 co-ordination chart for Star Delta starters with circuit-breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
10 37 66 38.1 '6,,%
(1) LC1D80A LC1D32 LRD3357 37..50
11 45 80 46.2 '6,,%
(1) LC1D115 LC1D65A LRD3357 37..50
12 55 97 56 '6,,%
(1) LC1D115 LC1D65A LRD3359 48...65
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬REPLACING¬THE¬
¬WITH¬THE¬BREAKING¬PERFORMANCE¬CODE¬AS¬PER¬TABLE¬GIVEN¬BELOW
NSX160*MA, NSX400*
Circuit breaker type NSX100*MA GV4L/LE80* GV4L/LE115*
NSX250*MA NSX630*
Breaking performance Iq (kA) at 400/415V 50 50 50 50 50
Breaking performance code N N N N N
For advanced protection, protection with Electronic Overcurrent Relays, heavy starting, please contact our sales teams.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 141
Type 2 Co-ordination chart
Type 2 co-ordination chart for Star Delta starter with circuit breaker and overload protection
built into circuit breaker
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
10 37 66 38.1 70 '60%0%-
(1) LC1D80A LC1D32
11 45 80 46.2 70 '60%0%-
(1)
LC1D115 LC1D65A
12 55 97 56.0 70 '60%0%-
(1)
LC1D115 LC1D65A
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬REPLACING¬THE¬
¬WITH¬THE¬BREAKING¬PERFORMANCE¬CODE¬AS¬PER¬TABLE¬GIVEN¬BELOW
GV4PE/ GV4PE/
Circuit breaker type GV5P150* GV5P220* GV5P320* GV6P500*
PEM80* PEM115*
Breaking performance Iq (kA) at 400/415V 70 70 70 70 50 50
Breaking performance code H H H H N N
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 142
Type 2 Co-ordination chart
Type 2 Co-ordination chart for Direct-On-Line starter with circuit breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
Sr.
3) Motor power in kW Circuit Breaker Contactor Thermal Overload Relay
No.
1 0.18 '6,,%
LC1D09 LRD05
2 0.25 '6,,%
LC1D09 LRD05
3 0.37 '6,,%
LC1D09 LRD06
4 0.55 '6,,%
LC1D09 LRD06
5 0.75 '6,,%
LC1D09 LRD07
6 1.1 '6,,%
LC1D25 LRD08
7 1.5 '6,,%
LC1D32+GV1L3 LRD08
8 2.2 '6,,%
LC1D32+GV1L3 LRD10
9 3 '6,,%
LC1D40A LRD12
10 4 '6,,%
LC1D65A LRD14
11 5.5 '6,,%
LC1D65A LRD313
12 7.5 '6,,%
LC1D65A LRD318
13 10 '6,,%
LC1D65A LRD325
14 11 '6,,%
LC1D65A LRD325
15 15 '6,,%
LC1D65A LRD332
16 18.5 '6,,%
LC1D65A LRD340
17 22 '6,,%
LC1D65A LRD350
18 30 '6,,%
LC1D65A LRD365
¬
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬REPLACING¬THE¬
¬WITH¬THE¬BREAKING¬PERFORMANCE¬CODE¬AS¬PER¬TABLE¬GIVEN¬BELOW
For Star Delta selection, use contactor same as DOL for Main, Star and Delta.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 143
Type-2 Co-ordination Chart
Type 2 Co-ordination chart for Direct-On-Line starter with Fuses and overload protection by
separate thermal overload relay
Reliable
switching for
IE2/IE3 motors IE2 IE3
Type 2 Co-ordination chart for Star Delta starter with Fuses and overload protection by
separate thermal overload relay
Reliable
switching for
IE2/IE3 motors IE2 IE3
2ATED¬OPERATIONAL¬VOLTAGE¬5E¬¬6¬(Z
3HORT¬#IRCUIT¬#URRENT¬)Q ¬¬K!
3) Motors Contactor Overload Relay
Sr. Fuse
FLC - In (Amps) SDF Fuse Star Main / Delta
No. kW HP Rating Type Range (A)
Line (A) Phase (A) Contactor Contactor
1 1.5 2 4 2.3 NX32 10NHC00G 10 LC1E09 LC1E09 LRE07 1.6-2.5
2 2.2 3 5 3 NX32 16NHC00G 16 LC1E09 LC1E09 LRE08 2.5-4
3 3 4 7 4 NX32 16NHC00G 16 LC1E09 LC1E09 LRE08 2.5-4
4 4 5.3 9 5 NX32 20NHC00G 20 LC1E09 LC1E09 LRE10 4-6
5 5.5 7.5 10 6 NX32 20NHC00G 20 LC1E09 LC1E09 LRE12 5.5-8
6 7.5 10 16 9 NX32 32NHC00G 32 LC1E09 LC1E09 LRE14 7-10
7 9 12 17 10 NX32 32NHC00G 32 LC1E09 LC1E12 LRE14 7-10
8 11 15 21 12 NX63 50NHC00G 50 LC1E12 LC1E12 LRE16 9-13
9 15 20 28 16 NX63 63NHC00G 63 LC1E18 LC1E18 LRE21 12-18
10 22 30 42 24 NX80 80NHC00G 80 LC1E25 LC1E25 LRE32 23-32
11 30 40 57 33 NX125 100NHG00B 100 LC1E40 LC1E40 LRE355 30-40
12 45 60 81 47 NX125 125NHG00B 125 LC1E40 LC1E50 LRE357 37-50
13 55 75 100 58 NX125 125NHG00B 125 LC1E40 LC1E65 LRE359 48-65
14 80 107 139 80 NX200 200NHG1B 200 LC1E80 LC1E80 LRE363 63-80
15 110 150 196 113 NX315 315NHG2B 315 LC1E300 LC1E300 LRE482 84~135
16 160 215 286 165 NX400 355NHG2B 355 LC1E300 LC1E300 LRE483 124~198
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 144
Selection Chart
Reliable
switching for
IE2/IE3 motors IE2 IE3
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 145
Selection Chart
Fuseless - Star Delta starters with circuit-breaker and overload protection by separate thermal
overload relay
Reliable
switching for
IE2/IE3 motors IE2 IE3
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 146
Selection Chart
Fuseless - Direct-on-Line starters with circuit-breaker and overload protection built into the
circuit-breaker
Reliable
switching for
IE2/IE3 motors IE2 IE3
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 147
Phaseo Power Supplies
ABL8 Ranges
Power Supply Rated Power
Input Voltage output Voltage Reference Unit LP [`]
Output Current In W
Modular Range (without PFC, Automatic Reset)
5 V DC 4A 20 W ABL8MEM05040 7429
100...240 V AC
12 V DC 2A 25 W ABL8MEM12020 6581
Universal Range (with PFC, Boost function, Diagnosis Contact, Automatic or Manual Reset)
24 V 3A 72 W ABL8RPS24030 11680
100...120 V single phase
24 V 5A 120 W ABL8RPS24050 15100
200...500 V 2 phase
24 V 10 A 240 W ABL8RPS24100 17250
100...120 V single phase
24 V 20 A 480 W ABL8RPM24200 ; 23800
200...240 V AC 2 phase
24 V 20 A 480 W ABL8WPS24200 25800
300...500 V AC three phase
24 V 40 A 960 W ABL8WPS24400 45000
Accessories
Description Reference Unit LP [`]
ABL 1
reversible mounting bracket - for regulated switch mode ABL1A01
405
mounting plate for 35 mm rail - for regulated switch mode ABL1A02
Note: To be ordered in lot of 5.
ABL 8 - Universal Range Accessories
Battery Back-up module 20A ABL8BBU24200 21945
Battery Back-up module 40A ABL8BBU24400 29415
Battery pack 7 Ah ABL8BPK24A07 15700
Buffer module 40A ABL8BUF24400 20900
Protection module with two pole breaking ABL8PRP24100 18285
Redundancy Module ABL8RED24400 13885
Protection module with single pole breaking ABL8PRE24100 12720
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 148
Phaseo Transformers
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 149
Phaseo Transformers
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 150
Altivar Variable Frequency Drives
Altivar12 Drive: 1-Phase / 3-Phase 230 Volts Input & 3-Phase 230 Volts Output Drive
tSmall: easily integrated in any machine
tDiscreet & Intuitive
tReliable: quality which stands the test of time
tHigh-performance: even without adjustment
Max. continuous
kW (HD) HP Rating Reference Unit LP [`]
current(A)
Single phase-Supply Voltage: 200…240V
0.18 0.25 1.4 ATV12H018M2 On request
0.37 0.55 2.4 ATV12H037M2 On request
0.55 0.75 3.5 ATV12H055M2 On request
0.75 1 4.2 ATV12H075M2 On request
1.5 2 7.5 ATV12HU15M2 On request
2.2 3 10 ATV12HU22M2 On request
Three phase-Supply Voltage: 200…240V
0.37 0.55 2.4 ATV12H037M3 On request
0.75 1 4.2 ATV12H075M3 On request
1.5 2 7.5 ATV12HU15M3 On request
2.2 3 10 ATV12HU22M3 On request
3 ~ 12.2 ATV12HU30M3 On request
4 5 16.7 ATV12HU40M3 On request
Altivar310 Drive: 3-Phase 440 Volts Input & 3-Phase 440 Volts Output Drive
Max. continuous
kW HP Rating Reference Unit LP [`]
current(A)
Three phase-Supply Voltage: 380…460V
0.37 0.5 1.5 ATV310H037N4E On request
0.75 1 2.3 ATV310H075N4E On request
1.5 2 4.1 ATV310HU15N4E On request
2.2 3 5.5 ATV310HU22N4E On request
3 4 7.1 ATV310HU30N4E On request
4 5 9.5 ATV310HU40N4E On request
5.5 7.5 12.6 ATV310HU55N4E On request
7.5 10 17 ATV310HU75N4E On request
11 15 24 ATV310HD11N4E On request
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 151
Altivar Variable Frequency Drives
Altivar610 Drive: Drives for pumps and fans from 0.75 to 160 kW
tComPact size: simplicity of integration and reduction of the size of the enclosures
tElectronic cards with protective coating
tOperation temperature: -10…+60°C
tIP40 protection level on the top of the product
tTypical multi-pump configuration without PLC
t7 preprogrammed function blocks cover 90% of the pump and fan applications
tColored control circuit terminals to avoid misuse
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 152
Altivar Variable Frequency Drives
Machine Drives
Note: References ending with B are BOOK type & Reference ending with C are ComPact type.
¬ 2EFERENCES¬ENDING¬WITH¬.7
¬ARE¬)0
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 153
Altivar Variable Frequency Drives
tReduced requirement for additional devices thanks to rich interfaces, I/Os, and
PTIs/PTOs, and an embedded encoder
t5 DI +2 (DI/DO);2 RO ;2 AI ;1 AO
t30kW…75kW : 8 DI ;1DO ;3RO ;3AI ;2AO
tDC choke inbuilt from 30kW and above
tHeavy duty 150%In for 60sec & 180%In for 2sec
tEmbedded STO SIL3
tOn board A/B/I & SinCos 1Vpp encoder
tChemical class for harsh environment 3C3
tHigh-speed native multi-Ethernet connectivity – real-time communication
t1 ms application cycle time
ATV340 Modular Drive: Power & Supply Voltage: 0.75 – 22 kW & 400/480 V three phase
!46¬%THERNET¬$RIVE!46
.% ¬0OWER¬¬3UPPLY¬6OLTAGE¬¬¬n¬¬K7¬¬¬6¬THREE¬PHASE
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 154
Altivar Variable Frequency Drives
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 155
Altivar Variable Frequency Drives
Altivar Process ATV930: Variable speed drives dedicated to constant torque application
with excellent motor control and connectivity capabilities (0.75kW to 315kW)
2EFERENCE¬ENDING¬WITH¬@#¬IS¬WITHOUT¬BRAKING¬UNIT
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 156
Altistart Softstarter
Soft Starter
ATS22 Soft Starter: Soft Starter for Utilities i.e. Pump & fan
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 157
Altistart Softstarter
Altistart 48 offers you the benefits of its patented Torque Control System (TCS). Ready for immediate start-up, with simplified
wiring and extended communication functions, it can be integrated at the heart of your applications in complete simplicity
For STD Application For Severe Application For STD Application For Severe Application
Reference Unit LP [`]
kW (400V) kW (400V) Nominal Current (Amps) Nominal Current (Amps)
Three phase-Supply Voltage: 230V…415V
7.5 5.5 17 12 ATS48D17Q On Request
11 7.5 22 17 ATS48D22Q On Request
15 11 32 22 ATS48D32Q On Request
19 15 38 32 ATS48D38Q On Request
22 18.5 47 38 ATS48D47Q On Request
30 22 62 47 ATS48D62Q On Request
37 30 75 62 ATS48D75Q On Request
45 37 88 75 ATS48D88Q On Request
55 45 110 88 ATS48C11Q On Request
75 55 140 110 ATS48C14Q On Request
90 75 170 140 ATS48C17Q On Request
110 90 210 170 ATS48C21Q On Request
132 110 250 210 ATS48C25Q On Request
160 132 320 250 ATS48C32Q On Request
220 160 410 320 ATS48C41Q On Request
250 220 480 410 ATS48C48Q On Request
315 250 590 480 ATS48C59Q On Request
355 315 660 590 ATS48C66Q On Request
400 355 790 660 ATS48C79Q On Request
500 400 1000 790 ATS48M10Q On Request
630 500 1200 1000 ATS48M12Q On Request
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 158
Zelio Logic Smart Relays
Zelio 2 ComPact smart relay Zelio 2 ComPact smart relay Zelio 2 modular smart relay
with display without display with display
Relays
Description Reference Unit LP [`]
Voltage 24V DC
Zelio Logic module - 10 I O, RLY - w/o clock - with display SR2A101BD ; 11700
Zelio Logic module - 20 I O, RLY - w/o clock - with display SR2A201BD ; 19100
Zelio Logic module - 12 I O,TRN - with clock - with display SR2B121BD ; 10700
Zelio Logic module - 12 I O,TRN - with clock - with display SR2B122BD 16050
Zelio Logic module - 20 I O, RLY - with clock - with display SR2B201BD ; 21250
Zelio Logic module - 20 I O, RLY - with clock - with display SR2B202BD 22100
Zelio Logic module - 10 I O, RLY - w/o clock - w/o display SR2D101BD ; 7500
Zelio Logic module - 20 I O, RLY - w/o clock - w/o display SR2D201BD ; 17150
Zelio Logic module - 12 I O, RLY - with clock - w/o display SR2E121BD 11000
Zelio Logic module - 20 I O, RLY - with clock - w/o display SR2E201BD 20800
Zelio Logic module - 10 I O, RLY - with clock - with display SR3B101BD 12900
Zelio Logic module - 10 I O, TRN - with clock - with display SR3B102BD 11900
Zelio Logic module - 26 I O, RLY - with clock - with display SR3B261BD ; 26800
Zelio Logic module - 26 I O, TRN - with clock - with display SR3B262BD 26850
Voltage 100-240V AC
Zelio Logic module - 10 I O, RLY - w/o clock - with display SR2A101FU ; 13250
Zelio Logic module - 20 I O, RLY - w/o clock - with display SR2A201FU ; 19650
Zelio Logic module - 12 I O, RLY - with clock - with display SR2B121FU ; 13150
Zelio Logic module - 20 I O, RLY - with clock - with display SR2B201FU ; 21850
Zelio Logic module - 10 I O, RLY - w/o clock - w/o display SR2D101FU 9550
Zelio Logic module - 20 I O, RLY - w/o clock - w/o display SR2D201FU 20250
Zelio Logic module - 12 I O, RLY - with clock - w/o display SR2E121FU 12100
Zelio Logic module - 20 I O, RLY - with clock - w/o display SR2E201FU 22750
Zelio Logic module - 10 I O, RLY - with clock - with display SR3B101FU 14500
Zelio Logic module - 26 I O, RLY - with clock - with display SR3B261FU ; 27700
Voltage 12V DC
Zelio Logic module - 12 I O - with clock - with display SR2B121JD 13750
Zelio Logic module - 20 I O - with clock - with display SR2B201JD 17500
Voltage 24V AC
Zelio Logic module - 12 I O - with clock - with display SR2B121B 13750
Zelio Logic module - 20 I O - with clock - with display SR2B201B 26300
Zelio Logic module - 20 I O - with clock - w/o display SR2E201B 20900
Zelio Logic module - 10 I O - with clock - with display SR3B101B 14600
Zelio Logic module - 24 I O - with clock - with display SR3B261B 29250
Note: Zelio Smart Relays are also available in other voltages. Please contact our nearest Sales Office for the same.
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 159
Zelio Logic Smart Relays
Accessories
Description Reference Unit LP [`]
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 160
Zelio Plug - In Relays
s¬¬!¬RELAYS¬WITH¬¬#/¬CONTACT¬AND¬¬!¬RELAYS¬WITH¬¬#/¬CONTACTS
s¬¬3OCKETS¬WITH¬SEPARATE¬CONTACT¬TERMINALS¬SCREW¬CONNECTOR¬¬CONNECTION¬AND¬BUILT
IN¬PLASTIC¬
maintaining clamp, 35mm DIN rail mounting and Panel mounting.
s¬/PTIONAL¬MODULES¬FOR¬ADDITIONAL¬PROTECTION
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 161
Zelio Plug - In Relays
s¬¬!¬RELAYS¬WITH¬¬#/¬CONTACT¬AND¬¬!¬RELAYS¬WITH¬¬#/¬CONTACTS
s¬3OCKETS¬WITH¬SEPARATE¬CONTACT¬TERMINALS¬SCREW¬CONNECTOR¬CONNECTION¬AND¬BUILT
IN¬PLASTIC¬
maintaining clamp, 35mm DIN rail mounting and Panel mounting.
s¬/PTIONAL¬MODULES¬FOR¬ADDITIONAL¬PROTECTION
Accessories
1CO Separate terminal socket with clamp RGZE1S35M 277
2CO Separate terminal socket with clamp RGZE1S48M 307
Plastic maintaining clamp for RGZ socket RGZR215 29
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 162
Zelio Plug - In Relays
Accessories
Description Reference Unit LP [`]
Sockets
Sockets - mixed-screw clamp - relay type RXM2 (without lockable test button) RXZE1M2C ; 176
Sockets - mixed-screw clamp - relay type RXM2/RXM4 (without lockable test button) RXZE1M4C ; 225
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 163
Zelio Plug - In Relays
Accessories
Sockets
socket for miniature relay - for RXM2N - with mixed contacts - screw clamp RXZE2M2N 187
socket for miniature relay - for RXM4N - with mixed contacts - screw clamp RXZE2M4N 212
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 164
Zelio Plug - In Relays
Control Circuit Voltage Reference Unit LP [`] Control Circuit Voltage Reference Unit LP [`]
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 165
Zelio Plug - In Relays
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 166
Zelio Electronic Timers/Control Relays
NEW
RE17 Electronic Timers
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 167
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Biometric Switch Pilot lights
Supply
Description Reference Unit LP [`] Description Colour Reference Unit LP [`]
Voltage
Bistable biometric switch, 24 V DC
XB5S1B2L2 31962
With smooth lens (except clear colour)
- PNP - by 2m cable
White XB7EV01BPN ; 240
Bistable biometric switch, 24 V DC Green XB7EV03BPN ; 222
XB5S1B2M12 33721
- PNP - by M12 connector
Red XB7EV04BPN ; 222
Monostable biometric switch, 24 V DC ~ 24V Yellow XB7EV05BPN ; 222
XB5S2B2L2 32380
- PNP - by 2m cable
Amber XB7EV08BPN ; 222
Monostable biometric switch, 24 V DC Blue XB7EV06BPN ; 457
XB5S2B2M12 33617
- PNP - by M12 connector
Clear 8"%6"0.
¬; 222
White XB7EV01GPN ; 240
Accessories Green XB7EV03GPN ; 222
Unit LP Red XB7EV04GPN ; 222
Description Reference Direct Integral LED ~ 120V
[`] Yellow XB7EV05GPN ; 222
Protective cover, translucent Amber XB7EV08GPN ; 222
ZB5SZ70 818
& self adhesive
Blue XB7EV06GPN ; 457
Diameter 22 mm nut ZB5SZ71 334 White XB7EV01MPN ; 240
Legend plate 28X7 mm ZBY0101T 155 Green XB7EV03MPN ; 222
Red XB7EV04MPN ; 222
~ 230V Yellow XB7EV05MPN ; 222
Amber XB7EV08MPN ; 222
Blue XB7EV06MPN ; 457
Pushbuttons
Clear 8"%6-0.
222
Type of
Description Colour Reference Unit LP [`]
¬#LEAR¬TYPE¬PILOT¬LIGHTS¬ARE¬PROVIDED¬WITH¬STRIATED¬LENS
Contact
Spring return
NO White XB5AA11N ; 149
NO Black XB5AA21N ; 149
NO Green XB5AA31N ; 149
NO Yellow XB5AA51N ; 149
Flush
NO Blue XB5AA61N ; 149
NC Red XB5AA42N ; 149
NO Red XB5AA41N ; 149
NO Blank 8"!!.
¬; 149
NO White XB5AL11N 188
NO Black XB5AL21N 182
NO Green XB5AL31N ; 182
Projecting NO Yellow XB5AL51N 182
NO Blue XB5AL61N 182
NC Red XB5AL42N ; 182
NO Red XB5AL41N 182
NO Black XB5AP21N ; 213
NO Green XB5AP31N ; 213
Flush with silicon
NO Yellow XB5AP51N ; 213
transparent boot
NO Blue XB5AP61N 219
NC Red XB5AP42N ; 213
NO Green XB5AA3311N 212
Flush, marked NC Red XB5AA4322N 212
(double molding NO Green XB5AA3331N ; 212
/injection marking) NC Red XB5AA4342N ; 212
NC Red XB5AA4352N 309
Projecting, marked NC Red XB5AL4342N 222
(double molding
/injection marking) NC Red XB5AL4352N 222
&LUSH¬MARKED¬@@)/ NO+NC Green XB5AL845N ; 1052
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 168
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Illuminated Pushbutton
Description Type of Contact Colour Reference Unit LP [`]
¬#LEAR¬TYPE¬ILLUMINATED¬0USH¬BUTTONS¬ARE¬PROVIDED¬WITH¬STRIATED¬LENS
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 169
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 170
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Non Illuminated Selector switches & Key switches Pushbutton caps (unmarked)
t For use with ZB5-AAON circular pushbutton heads supplied without caps
Type Type of
Colour Reference Unit LP [`]
Description of Reference Unit LP [`] Pushbutton caps
Contact White ZBA1N 53
2 stay put 1NO XB5AD21N ; 367 Black ZBA2N 37
2 spring return, Flush Red ZBA4N 35
1NO XB5AD41N ; 584
right to left Yellow ZBA5N 37
3 stay put 2NO XB5AD33N ; 400 Blue ZBA6N 37
Standard White ZBL1N 98
3 spring return
handle 2NO XB5AD53N ; 426
to center Yellow ZBL5N 98
black Projecting
3 spring return, Blue ZBL6N 98
2NO XB5AD73N ; 426 3ET¬OF ¬¬COLORS
ZBL9N 98
left to center
3 spring return,
right to center
2NO XB5AD83N ; 457 Pushbutton caps (marked)
2 stay put 1NO XB5AJ21N ; 371 Type of Colour Colour
Unit LP
Long 3 stay put 2NO XB5AJ33N ; 411 Pushbutton of Reference
Text Colour Cap [`]
handle caps
black 3 Spring return STOP White Red ZBL434N 153
2NO XB5AJ53N ; 429
to center
Projecting Flush ON White Green :"!.
152
¬STAY¬PUT
1NO XB5AG21N ; 562 (Double injection UP Black White ZBA343N 152
¬STAY¬PUT
1NO XB5AG021N 641 moulded marking) DOWN White Black ZBA344N 221
¬STAY¬PUT
1NO XB5AG41N 562 OFF White Red ZBA434N 147
2 spring return,
¬3ET¬OF ¬¬COLOURS¬WHITE¬¬BLACK¬¬GREEN¬¬RED¬¬YELLOW¬¬BLUE
1NO XB5AG61N 997
right to left
¬0LEASE¬REFER¬CATALOGUE¬FOR¬+EY¬WITHDRAWAL¬POSITION
Fixing nut ZB5AZ901N 30
Accessories
Contact blocks with screw clamp terminal connections
Legend
Description Marking Reference Unit LP [`]
Colour Description Type of Contact Reference Unit LP [`]
With blank legend Black/Red
Blank ZBY2101N ; 102 Standard single 1NO ZBE101N ; 87
(for engraving) bkgd.
Inch ZBY2321N 150 Contact blocks 1NC ZBE102N ; 87
With 8 x 27 mm Black or OFF ZBY2312N 150
English language Red
marked legend bkgd. ON ZBY2326N 150 Clear silicon boots
Reset ZBY2323N 150
Legends for Emergency Description Reference Unit LP [`]
ON ZBY9330N ; 102
emergency stop stop
Boot for cylindrical flush PB ZBPAN ; 59
Mushroom head Boot for double head illuminated PB and
Yellow bkgd. ZBY8330N 102 ZBW008N 153
pushbuttons non-illuminated PB
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 171
Harmony Control & Signalling Units
XB5 / XB7 Series (Lot size 20 nos.)
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 172
Signalling Control Stations & Enclosures
ZAL Bodies for LED Pilot light (for mounting on metal plate at back of enclosure)
XAL - Empty enclosures for XB5 and XB4 Push button and Pilot light
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 173
Signalling Control Stations & Enclosures
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 174
Magelis Industrial PC and Display
tOur comprehensive Magelis iPC range offers industrial PCs for improved productivity
and an enhanced user experience. Choose the right industrial PC for your
environment, from our wide range and be confident that they are designed to last
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 175
Magelis RACK IPC
RACK IPC
Magelis GTU
Magelis SCU
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 176
Magelis Basic HMI
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 177
Vijeo XD EcoStruxure™ Operator Terminal Expert
Vijeo XD
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 178
Vijeo Vijeo Designer
Vijeo Designer
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 179
Acti 9 Advanced Communication
Technology that Inspires
Innovative Efficient
Protection monitoring Total control and Manage loads, reduce operating and project
Metering @ DB level costs, and accurately plan maintenance
Please contact Customer Care Center for Stockable and Non stockable status of references.
;
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 180
> Control and monitoring > Installation system
s¬ #ONTACTORS s¬ )0"¬TERMINALS
s¬ )MPULSE¬RELAYS s¬ 3PLITTER¬BLOCKS
s¬ )NTEGRATED¬CONTROL¬CIRCUIT¬BREAKERS s¬ &ULL¬RANGE¬OF ¬MOUNTING¬AND¬
s¬ ,IGHT¬INDICATORS wiring accessories
s¬ 0USH
BUTTONS¬AND¬SELECTOR¬SWITCHES
s¬ +ILOWATT¬HOUR¬METERS
s¬ #OMMUNICATING¬ARCHITECTURE
Reliable
Dual certifications for one product, 100 percent MCB and RCD
coordination, easy ordering and design, error free fast connections
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 181
Advanced Communication
Acti 9 Technology that Inspires.....
> Innovative
s¬ #ENTRALIZED¬CONTROL¬SYSTEM¬INCLUDING¬ENERGY¬METERING
s¬,ARGE¬AND¬VARIABLE¬DATA¬READING¬AND¬COMPUTING¬THROUGH¬UNIVERSAL¬-ODBUS¬PROTOCOL NEW
> Efficient
Email Notification upon
s¬ /NE
CLICK¬PREFABRICATED¬WIRING¬FOR¬COMPREHENSIVE¬COMMUNICATION¬BETWEEN¬YOUR¬
distribution board or panel and any facility management system Event (Devices Status
> Reliable Change, Alarm threshold
s¬ %RROR¬PROOF ¬CONNECTION¬LEADING¬TO¬REDUCTION¬IN¬DOWNTIME reached etc.)
s¬ %-#¬TESTED¬FOR¬IMMUNITY¬RADIATED¬AND¬CONDUCTED¬SAFETY
Exclusive From
7 input/output Schneider Electric
channels
Load co
Protection monitoring
se.com/in 182
Ready to connect to any facility management solution
Energy Building
management Smart
management Internet Phone
PLC system
system
24 V DC
Power supply
Energy metering
ontrol switching
se.com/in 183
Acti 9 Miniature Circuit Breakers (MCBs)
Advanced Communication for circuit protection against Overload and Short Circuit Current Fault
Technology that Inspires...
s¬INCREASED¬3YSTEM¬#ONTINUITY¬$ISCRIMINATION
B curve
6 A9N1P06B ; 330 A9N2P06B ; 995 A9N3P06B ; 1628 A9N4P06B 2195
10 A9N1P10B ; 330 A9N2P10B ; 995 A9N3P10B ; 1628 A9N4P10B ; 2195
16 A9N1P16B ; 330 A9N2P16B ; 995 A9N3P16B ; 1628 A9N4P16B ; 2195
20 A9N1P20B ; 330 A9N2P20B ; 995 A9N3P20B ; 1628 A9N4P20B ; 2195
25 A9N1P25B ; 330 A9N2P25B ; 995 A9N3P25B ; 1628 A9N4P25B ; 2195
32 A9N1P32B ; 330 A9N2P32B ; 995 A9N3P32B ; 1628 A9N4P32B ; 2195
40 A9N1P40B ; 729 A9N2P40B ; 1607 A9N3P40B ; 2483 A9N4P40B ; 3161
50 A9N1P50B 729 A9N2P50B 1607 A9N3P50B 2483 A9N4P50B 3161
63 A9N1P63B ; 735 A9N2P63B ; 1622 A9N3P63B ; 2504 A9N4P63B ; 3192
C curve
1 A9N1P01C ; 512 A9N2P01C ; 1386 A9N3P01C ; 2142 A9N4P01C ; 2704
2 A9N1P02C ; 512 A9N2P02C ; 1386 A9N3P02C ; 2142 A9N4P02C ; 2704
3 A9N1P03C ; 512 A9N2P03C ; 1386 A9N3P03C ; 2142 A9N4P03C ; 2704
4 A9N1P04C ; 512 A9N2P04C ; 1386 A9N3P04C ; 2142 A9N4P04C ; 2704
6 A9N1P06C ; 323 A9N2P06C ; 995 A9N3P06C ; 1628 A9N4P06C ; 2195
10 A9N1P10C ; 323 A9N2P10C ; 995 A9N3P10C ; 1628 A9N4P10C ; 2195
16 A9N1P16C ; 323 A9N2P16C ; 995 A9N3P16C ; 1628 A9N4P16C ; 2195
20 A9N1P20C ; 323 A9N2P20C ; 995 A9N3P20C ; 1628 A9N4P20C ; 2195
25 A9N1P25C ; 323 A9N2P25C ; 995 A9N3P25C ; 1628 A9N4P25C ; 2195
32 A9N1P32C ; 323 A9N2P32C ; 995 A9N3P32C ; 1628 A9N4P32C ; 2195
40 A9N1P40C ; 729 A9N2P40C ; 1607 A9N3P40C ; 2483 A9N4P40C ; 3100
50 A9N1P50C 729 A9N2P50C 1607 A9N3P50C 2483 A9N4P50C 3192
63 A9N1P63C ; 735 A9N2P63C ; 1622 A9N3P63C ; 2504 A9N4P63C ; 3131
D curve
1 A9N1P01D ; 517 A9N2P01D 1397 A9N3P01D ; 2184 ---- ----
2 A9N1P02D ; 517 A9N2P02D ; 1397 A9N3P02D ; 2184 A9N4P02D 2720
3 A9N1P03D ; 517 A9N2P03D ; 1397 A9N3P03D ; 2184 A9N4P03D 2720
4 A9N1P04D ; 517 A9N2P04D ; 1397 A9N3P04D ; 2184 A9N4P04D 2720
6 A9N1P06D ; 435 A9N2P06D ; 1044 A9N3P06D ; 1712 A9N4P06D ; 2279
10 A9N1P10D ; 435 A9N2P10D ; 1044 A9N3P10D ; 1712 A9N4P10D ; 2279
16 A9N1P16D ; 435 A9N2P16D ; 1044 A9N3P16D ; 1712 A9N4P16D ; 2279
20 A9N1P20D ; 435 A9N2P20D ; 1044 A9N3P20D ; 1712 A9N4P20D ; 2279
25 A9N1P25D ; 435 A9N2P25D ; 1044 A9N3P25D ; 1712 A9N4P25D ; 2279
32 A9N1P32D ; 435 A9N2P32D ; 1044 A9N3P32D ; 1712 A9N4P32D ; 2279
40 A9N1P40D ; 785 A9N2P40D ; 1701 A9N3P40D ; 2630 A9N4P40D ; 3302
50 A9N1P50D 785 A9N2P50D 1701 A9N3P50D 2630 A9N4P50D 3302
63 A9N1P63D 794 A9N2P63D ; 1717 A9N3P63D ; 2657 A9N4P63D ; 3334
Note:¬
¬0LEASE¬CONTACT¬NEAREST¬3CHNEIDER¬%LECTRIC¬3ALES¬/FlCE¬OR¬#USTOMER¬#ARE¬#ENTER¬FOR¬COORDINATION¬CHART¬
MMMODULE¬¬ ¬ ¬ ¬ ¬ ¬ ¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 184
Acti 9 Miniature Circuit Breakers (MCBs)
Advanced Communication for circuit protection against Overload and Short Circuit Current Fault
Technology that Inspires...
[In] Rated Module Width 18mm/ 1 Pole Module Width 18mm/ 2 Pole
Unit LP [`] Unit LP [`]
Current (A) module Reference module Reference
MOQ 12 Nos. 6 Nos.
C60H-DC
0.5 1 A9N61500 985 2 A9N61520 2079
1 1 A9N61501 ; 872 2 A9N61521 ; 1806
2 1 A9N61502 ; 872 2 A9N61522 ; 1806
3 1 A9N61503 ; 872 2 A9N61523 ; 1806
4 1 A9N61504 ; 872 2 A9N61524 ; 1806
5 1 A9N61505 872 2 A9N61525 1806
6 1 A9N61506 ; 716 2 A9N61526 ; 1528
10 1 A9N61508 ; 716 2 A9N61528 ; 1528
16 1 A9N61511 ; 716 2 A9N61531 ; 1528
20 1 A9N61512 ; 716 2 A9N61532 ; 1528
25 1 A9N61513 ; 716 2 A9N61533 ; 1528
32 1 A9N61515 ; 716 2 A9N61535 ; 1528
40 1 A9N61517 ; 981 2 A9N61537 ; 2168
50 1 A9N61518 ; 981 2 A9N61538 ; 2168
63 1 A9N61519 ; 981 2 A9N61539 ; 2168
MMMODULE
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 185
Acti 9 Miniature Circuit Breakers (MCBs)
Advanced Communication for circuit protection against Overload and Short Circuit Current Fault
Technology that Inspires...
16 18611
18622
18633
18650
20 18612
18623
18634
18651
25 18613
18624
18635
18652
32 18614
18625
18636
18653
40 18615
18626
18637
18654
50 18616
18627
18638
18655
63 18617
18628
18639
18656
80 18618
18629
18640
18658
16 18706
18715
18724
18733
20 18707
18716
18725
18734
25 18708
18717
18726
18735
32 18709
18718
18727
18736
40 18710
18719
18728
18737
50 18711
18720
18729
18738
63 18712
18721
18730
18739
80 18713
18722
18731
18740
16 18778
18789
18800
18811
20 18779
18790
18801
18812
25 18780
18791
18802
18813
32 18781
18792
18803
18814
40 18782
18793
18804
18815
50 18783
18794
18805
18816
63 18784
18795
18806
18817
80 18785
18796
18807
18818
Price on Request – Please contact Schneider Electric Customer Care Center for Prices
MMMODULE
Note: Reference provided above are for C Curve MCBs – B and D Curve details available on request
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 186
Residual Current Devices (RCDs) -
For Human and Fire Protection
Use of 30mA RCDs is now mandatory for all domestic intallations in India {CEA
!MENDMENT¬REGULATION¬
]
Schneider Electric provides voltage independent RCDs which work on current sensing
technology and provide protection from residual current even at extra low voltages
(down to zero volts) and in case of break of neutral.
¬FOR¬-EASURES¬RELATING¬TO¬3AFETY¬AND¬%LECTRIC¬SUPPLY
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 187
Acti 9 Residual Current Devices
Advanced Communication for protection against Risk of Shock / Electrocution and Risk of Fire
Technology that Inspires... in case of Earth Leakage Current.
!2 12403
100
100 4
!2 13070
4P 30 4 16905 37983
125 100 4 16906 36981
300 4 16907 37154
Note:
&OR¬!¬2##"¬!UXILIARY¬KINDLY¬CONTACT¬#USTOMER¬#ARE
Note: Application specific RCDs also available with 10mA, 500mA and 1000mA sensitivities | Please contact nearest Schneider Electric Sales Office or
Customer Care Center for Reference and Prices
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 188
Acti 9 Residual Current Devices
Advanced Communication for protection against Risk of Shock / Electrocution and Risk of Fire
Technology that Inspires... in case of Earth Leakage Current.
6
300 2 A9N19641
30 2 A9N19632
10
300 2 A9N19642
30 2 A9N19634
16
300 2 A9N19644
30 2 A9N19635
1P+N 20
300 2 A9N19645
30 2 A9N19636
25
300 2 A9N19646
30 2 A9N19637
32
300 2 A9N19647
30 2 A9N19638
40
300 2 A9N19648
For Prices, please contact nearest Schneider Electric Sales Office or Customer Care Center are Center for Reference and Prices
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 189
Acti 9 Auxiliaries and Accessories for
Advanced Communication
Technology that Inspires...
MCBs / RCDs
54 mm max.
+ + + + + + +
Module Width
Type Reference Unit LP [`]
18mm/module
Indication Auxiliaries
OF Auxiliary Switch: for ON/OFF indications 0.5 A9N26924 1006
SD Alarm Switch: for Trip on fault indications 0.5 A9N26927 1181
OF + SD/OF Auxiliary switch 0.5 A9N26929 3145
OF+SD24 auxiliary contact (ComReady) 0.5 A9N26899 2636
Protection Auxiliaries – Trip Indication on front face
MN Under-voltage Release 220-240V AC 1 A9N26960 4232
MSU Over-voltage Release 275V AC 1 A9N26500 5014
Tripping Auxiliaries – Trip Indication on front face
MX + OF Shunt Release 110-415V AC: for Remote tripping of Circuit Breaker 1 A9N26946 2751
MX + OF Shunt Release 12-24V AC/DC: for Remote tripping of Circuit Breaker 1 A9N26948 2751
Auxiliary Switch for RCCBs – Mandatory for use of Auxiliaries with RCCBs
Auxiliary switch for RCCB up to 80A (OF-S) 0.5 A9N26923 1344
Auxiliary switch for RCCBs 125A (OFSP) 0.5 16940 2042
Accessories
19096 1260
ALUMINUM¬CABLE¬TERMINAL
27060 476
Spacer A9N27062 198
for xC60, C120, DPN N Vigi, C60H-DC, xSW - Multi poles only
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 190
Protection Against Lightning Strikes And
Switching Surges
90%
of power outlets
supply equipment
incorporating
electronic devices.
I1UICK¬02$¬@@BUILT
IN¬TECHNOLOGY¬SURGE¬ARRESTERS
a Schneider Electric innovation, incorporate their
own disconnection circuit breaker: easy to choose Up to 30%
and simple to install for greater effectiveness. of installation
time saved.
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 191
Acti 9 Surge Protection Devices
Advanced Communication for protection of equipment against Lightning and Switching surges
Technology that Inspires...
Module Width
Type Pole Description Reference Unit LP [`]
18mm/module
1P 2 16329 13655
1P + N 4 16330 30041
PRD1 25r
3P 6 16331 45050
3P + N 8 16332 55970
Surge Arresters iPRD- Type 2 (Withdrawable type) (TT, TN-S, TN-C Systems)
s¬In conformance with standards IEC 61643-11/2011 T2 and EN 61643-11 Type 2
s¬For protection against Indirect lightning surge and Switching surge
s¬Inbuilt health Indicator
s¬RESPONSE¬TIME¬¬NS
s¬lmax (8/20 s): 65/40/15/8kA
s¬Maximum Operating Voltage [Uc]: 340V
s¬Level of protection,Up: 1.0 - 2.0 kV
s¬Remote indication contact with 8r/20r/40r/65r
s¬Always use a Back-up MCB with your SPD
Module Width
Type Rated Voltage (V) Pole Description Reference Unit LP [`]
18mm/module
230 1P 1 A9L08100 4095
230 1P+N 2 A9L08500 7660
iPRD8
230/400 3P 3 A9L08300 10343
230/400 3P+N 4 A9L08600 15614
230 1P+N 2 A9L08501 9182
iPRD8r
230/400 3P+N 4 A9L08601 18737
230 1P 1 A9L20100 4594
230 1P+N 2 A9L20500 9634
iPRD20
230/400 3P 3 A9L20300 12332
230/400 3P+N 4 A9L20600 17438
230 1P+N 2 A9L20501 11456
iPRD20r
230/400 3P+N 4 A9L20601 21326
230 1P 1 A9L40100 5429
230 1P+N 2 A9L40500 11093
iPRD40
230/400 3P 3 A9L40300 15929
230/400 3P+N 4 A9L40600 22218
230 1P 1 A9L40101 6510
230 1P+N 2 A9L40501 14306
iPRD40r
230/400 3P 3 A9L40301 21441
230/400 3P+N 4 A9L40601 26660
230 1P 1 A9L65101 8705
230 1P+N 2 A9L65501 18233
iPRD65r
230/400 3P 3 A9L65301 23793
230/400 3P+N 4 A9L65601 30875
Spare Cartridges
Type Reference Unit LP [`]
for
iPRD 65-350 iPRD65r A9L65102 5450
iPRD 40-350 iPRD40, iPRD40r A9L40102 4190
iPRD 20-350 iPRD20, iPRD20r A9L20102 3355
iPRD 8-350 iPRD8, iPRD8r A9L08102 2940
iPRD Neutral All products (1P+N, 3P+N) A9L00002 4410
3PARE¬Cartridges for Old SPD Range (A9L16...) are available on demand - please contact nearest Schneider Electric Sales Office or Customer Care for Reference and prices
Note: NOTE¬&OR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 192
Acti 9 Surge Protection Devices
Advanced Communication for protection of equipment against Lightning and Switching surges
Technology that Inspires...
Module Width
Type Pole Description Reference Unit LP [`]
18mm/module
1P+N 4 A9L16298 11772
iQuick PRD 8r 3P 6.5 A9L16299 16816
3P+N 7.5 A9L16300 20927
1P+N 4 A9L16295 13729
iQuick PRD 20r 3P 6.5 A9L16296 20186
3P+N 7.5 A9L16297 25111
1P+N 4 A9L16292 16034
Quick PRD 40r 3P 6.5 A9L16293 24024
3P+N 7.5 A9L16294 29857
Note: Spare / Replacement Cartridges available - For Reference and prices contact nearest sales office or customer care
Module Width
Type U (cpv) Maximum Operating Voltage (V) Reference Unit LP [`]
18mm/module
800 3 A9L40271 9130
iPRD 40r
1000 3 A9L40281 10432
Note: Spare / Replacement Cartridges available - For Reference and prices contact nearest sales office or customer care
Module Width
Type [Ue] Operational Voltage (V) Reference Unit LP [`]
18mm/module
PRI 48 V DC 1 A9L16339 16286
PRC 130 V AC 1 A9L16337 9959
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 193
Acti 9 Control and Command Products
Advanced Communication for Load Control, Switching and Indication
Technology that Inspires...
Isolator - xSW
s¬Complies to IEC/EN 60947-3
s¬Switching duty: AC-22
s¬Impulse voltage: 6kV
s¬DC application: 48V (110V with 2 poles in series)
s¬Short circuit withstand 20 In for 1 second
s¬Upto 80A Bi connect terminals & 100A to 125A with mono connect terminals
Module Width
Poles Description [In] Rated Current (A) MOQ Reference Unit LP [`]
18mm/module
40 2 6 A9S2P040 611
63 2 6 A9S2P063 809
2 80 2 6 A9S2P080 970
100 2 6 A9S2P100 1407
125 2 6 A9S2P125 1454
40 3 4 A9S3P040 1076
3
63 3 4 A9S3P063 1260
40 4 3 A9S4P040 1360
63 4 3 A9S4P063 1486
4 80 4 3 A9S4P080 1969
100 4 3 A9S4P100 2216
125 4 3 A9S4P125 2394
Module Width
No. of positions Poles Description Contacts MOQ Reference Unit LP [`]
18mm/module
1 1 C/O 1 12 A9E18070 1265
2 2 C/O 2 6 A9E18071 1743
2
1NO + 1NC 1 12 A9E18072 1012
1 1 C/O 1 12 A9E18073 1244
3
2 2 C/O 2 6 A9E18074 2105
iRO Buzzers
s¬Audible indication in housing and the tertiary sector
s¬Sound level of 70dBA at a distance of 60cm
Module Width
Voltage Reference Unit LP [`]
18mm/module
230V AC 1 A9A15322 1076
8..12V AC 1 A9A15323 897
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 194
Acti 9 Control and Command Products
Advanced Communication for Load Control, Switching and Indication
Technology that Inspires...
iCT Contactors
s¬Complies with standards IEC 1095, E N 61095
s¬4 operating modes switch on front face :
q Automatic mode
q Temporary “ON” mode
q Permanent “ON” mode
q Shutdown
s¬Mechanical contact position Indicator
s¬Safe installation maintainance: lock the contactor in ON position
s¬Silent operation (20dB) for entire range
Module Width
Type Rating (A) No. of Contacts Reference Unit LP [`]
18mm/module
1P 25 1NO 1 A9C20731 1958
16 2NO 1 A9C22712 2016
25 2NO 1 A9C20732 2410
2P
40 2NO 2 A9C20842 4127
63 2NO 2 A9C20862 5271
25 3NO 2 A9C20833 3056
3P 40 3NO 2 A9C20843 6899
63 3NO 3 A9C20863 7497
25 4NO 2 A9C20834 3250
40 4NO 2 A9C20844 7035
4P
63 4NO 3 A9C20864 8479
63 2NO + 2NC 3 A9C20868 8479
Note: 100A Contactor in 2P / 4P - available on request
Type Rating (A) Control Voltage No. of Contacts Module Width Reference Unit LP [`]
16 230-240 VAC 1NO 1 A9C30811 1265
1P
32 230-240 VAC 1NO 1 A9C30831 1591
16 230-240 VAC 2NO 1 A9C30812 2079
2P
32 230-240 VAC 2NO 1 A9C30831 + A9C32836 4935
16 230-240 VAC 1NO+1NO/NC+1NO 2 A9C30811 + A9C32816 3948
3P
32 230-240 VAC 1NO+1NO/NC+1NO 2 A#¬¬
¬X¬!# 8279
16 230-240 VAC 4NO 2 A9C30814 4316
4P
32 230-240 VAC 4NO 2 A#¬¬
¬X¬!# 11623
Module Width
Type Colour Reference Unit LP [`]
18mm/module
Red 1 A9E18320 1187
Green 1 A9E18321 1187
Single Indicator light
Blue 1 A9E18323 1187
Orange 1 A9E18324 1187
3 phase voltage presence light Red/Red/Red 1 A9E18327 3113
Single Push Button (1 NO+ 1NC) Grey 1 A9E18033 1764
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 195
Acti 9 ComReady Control and
Advanced Communication
Technology that Inspires...
Command Products
Smartlink
s¬Compliance to IEC/EN 61131-2
s¬Protection Monitoring – Device Status and alarm notifications
s¬Load Control / Switching through Contactors and Impulse Relays
s¬Energy Monitoring through pulse meters
s¬Alarm over email and analog sensors (temperature / humidity) with Smartlink
Ethernet
s¬Plug & Play – Pre fabricated cables and in built web pages
s¬Rated Voltage: 24V DC
Communication Auxiliaries
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 196
Acti 9 ComReady Control and
Advanced Communication
Technology that Inspires...
Command Products
Prefabricated Cables:
With 2 Connectors
Short: 100mm 6 A9XCAS06 5339
Medium: 160mm 6 A9XCAM06 5392
Long: 870mm 6 A9XCAL06 6132
With 1 Connector
Long:870mm 6 A9XCAU06 3686
Connectors
5-pin connectors (Ti24) 12 A9XC2412 7429
Mounting Kit
Din Rail (4 feet, 4 Straps, 4 Adapters) 1 A9XMFA04 1460
Multiclip
Multiclip 80A 1 04000 8930
Spare Parts
Lock for Multiclip 80A (2 clips) 1 A9XMLA02 445
Distribloc 63A
Distribution from the top (4 Module) 1 04040 10169
Distribution through the bottom (4 Module) 1 04041 10169
Power Logic EGX300 - Ethernet port (4 Module) 1 30002885 30809
ABL Power Supply - 1.2A 24VDC 1 ABL8MEM24012 6720
ABL Power Supply - 0.6A 24VDC 1 ABL8MEM24006 4950
Double DIN rail 1 LSL58801A 725
MMMODULE
se.com/in 197
Acti 9 ComReady Control and
Advanced Communication
Technology that Inspires...
Command Products
Energy Meters
s¬Digital Kilowatt-hour meters designed for sub-metering of active energy (rms)
consumed by a single-phase or three-phase electric circuit with or without
distributed neutral
s¬ComReady DB mountable version
s¬Accuracy class-1
s¬No External CT required
iEM 2000T 1Ph Energy Meter upto 40A, POP w/o Display A9MEM2000T 4899
iEM3110 3 Phase Energy Meter Energy Meter with POP Accuracy CL 1.0 A9MEM3110 11700
iEM3150 3 Phase Energy Meter Energy Meter with V,I,Power, Accuracy CL 1.0, with Modbus A9MEM3150 12781
iEM3155 Multifunction 3 Phase Energy Meter with V,I,F,PF,Power, Energy,1DI/1DO, Multi Tariff,
A9MEM3155 13541
with Modbus Accuracy CL 1.0
Note: For Higher Currents /Loads , Select iEM32 Series , CT Operated , Accuracy CL 0.5S
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 198
Acti 9
Distribution Boards
Unique Rounded Corners | Color - RAL 9003 white | Designer Rotary Knob
Removed all
injurious sharp
corners
15% more wiring area | Reduced U-box Collar | Removable Frame, Centre plate & Gland plate
se.com/in 199
Inspiring the S.M.A.R.T. choice!!!
IK-08
IK
tested
Single Door
IK-09
Double Door
Green
Product
High Strength-to-Weight ratio | RoHS and REACH Compliance – ideal solution for GREEN Buildings
Designed and Manufactured as per IS 8623 - 1&3 | IP and IK test by ERDA & CPRI | Glow wire tested
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 200
Acti 9
Distribution Boards
DB identification label Fast and Easy removal of Plastic Stud for easy
Revolutionary EPDM Gasket ensuring IP43 and safe removal of
with manufacturing Gland Plate with reduced
protection and higher service life Center Plate
details number of screws
Convenient Installation
with Common combi-
head screws for both
Centre Plate and Frame
Embossed
earthing symbol for
easy identification
throughout service
life
Door earthing to
protect against
electric shock
Interconnecting
FRLS wireset to limit
fire damage in case
of fault
Cement Spill Protector
provided with DB to
safeguard against Insulated phase
dust and cement busbars for fast and
during installation easy connection of
components and safety
during maintenance
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 201
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
Metal Enclosures
s¬Metal Enclosure to mount individual Modular Device feeding directly to the load
or final distribution board
SPN DBs
s¬SPN DB for distribution of Single Phase Neutral supply to respective load MCBs
s¬Incomer - DP RCCB/RCBO/Isolator/MCB
s¬Outgoing - SP MCBs
TPN DBs
s¬Standard TPN DBs for distribution of Three Phase and Neutral supply
s¬Incomer - FP RCCB/RCBO/Isolator/MCB
s¬Outgoing - SP MCBs
s¬T0.¬$"S¬CAN¬BE¬CONVERTED¬TO¬00)¬$"¬USING¬@00)¬+IT¬PROVIDED¬ON¬NEXT¬PAGE
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 202
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
PPI Kit (to convert TPN and Flexi Tier DBs to PPI DB)
s¬Set of accessories to convert TPN DBs and 4 tier Flexi DBs to PPI DB
s¬Kit is provided with additional required quantity of N-Bar, wire set, Busbars (only
for Flexi Tier) and Mounting Kit (only for TPN)
PPI Kit for 6way TPN DB (2+4w PPI DB) A9HKIT04 ; 3098
PPI Kit for 8way TPN DB (2+6w PPI DB) A9HKIT06 ; 3628
PPI Kit for 12way TPN DB (2+10w PPI DB) A9HKIT10 ; 4001
PPI Kit for 4T40M Flexi DB (2+8w PPI DB) A9HKIT08 ; 6421
PPI Kit for 4T56M Flx DB (2+12w PPI DB) A9HKIT12 ; 7103
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 203
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
ComReady DBs
s¬Designed to house Acti 9 communication system
s¬Supplied with Double DIN rail, E-Bar and Wire channel.
s¬Accessories to convert Flexi Tier DB into ComReady DB available on request
s¬PLUG¬¬3OCKET¬5NIT¬WITH¬PROVISION¬TO¬MOUNT¬0RATI+A¬STRAIGHT¬¬ANGLED
¬SOCKET¬AND¬
modular protection devices to feed the end load directly
se.com/in 204
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
Key Lock
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 205
Kaedra Enclosures Weather Proof
Kaedra enclosures for PratiKa industrial sockets are part of a complete system of Watertight enclosures from
16A to 125A providing solutions for protection, control and electrical distribution for tertiary and industrial
applications
s¬Degree of protection - IP65
s¬Impact strength - IK09
s¬Resistant to chemical and atmospheric agents, UVs etc.
s¬Self extinguishing class 2 insulating material
s¬Flame and abnormal heat resistance: 650°C
s¬Reversible front face for opening of door to left/right
s¬Combining of enclosures horizontally/vertically while still maintaining IP
s¬DIN channel can be positioned in 2 depths & 2 heights for cabling purpose
Mini Enclosure (suitable to mount modular devices and PratiKa 16A socket)
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 206
Kaedra Enclosures Weather Proof
Enclosure (suitable to mount modular devices and PratiKa 16A / 32A sockets)
Functional Plaques
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 207
PratiKa Plugs and Sockets - IP44 / IP67
Wander Plugs
s¬Conforms to IEC 60309-1 & IEC 60309-2
s¬PK PratiKa Screw Connect: same orientation of clamp’s screws
s¬External impact strength: IK08
s¬Glow wire test: 850°C
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 208
PratiKa Plugs and Sockets - IP44 / IP67
Wander Sockets
s¬PK PratiKa Screw Connect: same orientation of clamp’s screws.
s¬PK PratiKa: 16A & 32A; IP44 & IP67
s¬External impact strength: IK08
s¬Glow wire test: 850 °C
s¬Conforms to IEC 60309-1 & IEC 60309-2
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 209
PratiKa Plugs and Sockets - IP44 / IP67
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 210
PratiKa Plugs and Sockets - IP44 / IP67
Socket with Interlock Switch & DIN Rail lsoblock (4.5 modules )
s¬Switch designed for use in AC- 22A class applications
s¬Conforms to IEC 60309-1 & IEC 60309-2
s¬Provision to DIN mount 4.5 module device
s¬External impact strength: IK10
s¬Available in IP65 version
s¬Glow wire test: 850°C
Note: FOR¬ALL¬ABOVE¬2EFERENCE¬-/1¬¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 211
Electra Metal Clad Plugs & Sockets
ELECTRA Metal Clad Plugs & Sockets are specially designed incorporating the latest safety, quality and user
friendly features.
Construction
s The casting is made from non-corroding die-cast aluminum alloy combining exceptional ComPactness with high strength
s The design/construction eliminates the possibility of mismatch in fitting of plugs in corresponding sockets
s The floating contacts in the sockets are self aligning and facilitates smooth plugging in without undue pressure (These can be easily
removed for wiring )
s A provision for pilot pin facilitates mechanical interlocking in case of 63A ratings
Human Safety
Specially designed shroud to avoid accidental finger contact with plug-pins while inserting/removing the plug
Similarly, the contact tubes in sockets are deeply recessed to avoid human contact
s The earthing pins ensure that earth connection is made first and broken last, being longer than conducting pins
s The visible earth terminals facilitate easy checking of earth connection
s The cable grip to the plug is made very strong by providing a compression gland and by protecting it at the point of entry by a strong
rubber guard
Applications
Industrial, Commercial & Domestic portable equipments like Hand/Power Tools, Industrial Ovens, Welding Sets, Mobile Generators,
Furnaces, Ships, Office Machines, Refrigerators, Coolers, Air-Conditioners, Overhead Cranes, Chilling Cabinets, Tile Polishers and
Sewing Machines
Plug
Unit MRP
Rating (A) Poles Description Voltage (V) MOQ Reference
[`]
10 2P 250 30 AP10 ; 208
20 2P 250 30 AP20 ; 218
20 3P 440 30 BP20 ; 290
30 3P 440 20 BP30 ; 529
63 3P+N+E 440 4 CP63 ; 2394
Socket
Unit MRP
Rating (A) Poles Description Voltage (V) MOQ Reference
[`]
10 2P 250 30 AS10 ; 218
20 2P 250 30 AS20 ; 256
20 3P 440 30 BS20 ; 326
30 3P 440 20 BS30 ; 561
63 3P+N+E 440 4 CS63 ; 2536
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 212
Price On Request
Power
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 213
Powering the Digital Future Today
Discover Our Power Monitoring Solutions
Basic
EM6400NG PM5340/5320 PM2000 iEM3000
Energy and Power
Monitoring, VAF-PF
Entry
HEXA iEM2XXX EM1XXX DM52XX DM6XXX DM3XXX/DM1XXX
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 214
!"#$%
PQ Analyser
PowerLogicTM&'*+++/
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 215
01/
&
2
32
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 216
6
!"#
Accurate Advanced Power
Quality Analyser
PowerLogicTM&'*+++
Meet the future of advanced power quality metering. Modular design,
78
9
&'*+++
9
9
/
9
13+102
7
%
1#
;
&'*+++
%
critical power systems.
<
3
3=>+102
>?@+GI@@7
<
2 N
=0+@U2
V>
/
@+X2YG+<[
69
6
6
\666]=^
V6%
2 V2%
%
!
> _2
3
@`&9#
%
>9
2
6
+@N2UjG%
#9#
$z>?0+++UI+>37>?@Gj?0V@
$z2
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 217
@1<
372
[
2#{V|{69
NEW
2.2 PowerLogicTM ION9000 Price On Request
> Summarize power quality, set targets, measure and verify results
> Large Color Display with high resolution
> Modbus Master functionality to read from downstream Modbus devices
and view it via the front panel
> Detect and capture transients as short as 20μs at 50Hz (17μs at 60 Hz)
> Power quality compliance monitoring IEC 61000-4-30 Class A , test
methods as per IEC 62586-1/2.
> 2 GB of standard non-volatile memory.
> Trend curves and short-term forecasting of upcoming values for better
decisions
> Disturbance direction detection with results captured in the event log, with
a timestamp and certainty level
> 50+ definable alarms to log critical event data, trigger waveform recording,
or perform control function.
> Trigger on any condition, with 1/2-cycle and 1-second response time.
> Support protocol: Modbus, ION, DNP3, DLMS, SNMP, and IEC 61850.
> Gateway functionality to access downstream meter’s readings through
ethernet
> Time synchronization via GPS clock (RS-485) or IRIG-B (digital input) to ±1
millisecond.
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 218
@1<
372
[
2#{V|{69
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 219
Simplifying power quality,
[
$%
| }$#j+++
Power Quality Analyser
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 220
I1<
37>$7$%
#
<{V#{V|{69
¬#LASS¬3¬COMPLIANCE¬AVAILABLE¬IN¬PHW¬SYSTEM
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 221
The easy choice for quality,
value, and simplicity.
EasyLogicTM$#@+++
3
3>+1G2V01+
>?@+GI@@V@0
62 ^2%
6
6
0@\> 9
]2
{737$%
_
N
>
> 9
>&@
NEW
9
&#
6 &V3 &
>9<
9
|6
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 222
I1<
372
[
2#{V|{69
¬/PTIONAL¬)/¬MODULES¬CAN¬BE¬USED¬FOR¬0-¬¬0-¬MODELS¬ONLY¬-AXIMUM¬UPTO¬¬MODULE¬CAN¬BE¬USED¬PER¬DEVICE¬AT¬A¬TIME
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 223
The future of
multifunction meters
is here
/
%<
2
#?U++'2
3'
% 3'
%
<
#?U++'
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 224
U1"#/
7N
9
3
##
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 225
G1"#/
7N
9
3
##
EM6436H CONZERV EM6436H VAF+ PF + Power & Energy Meter, Class accuracy 1.0 METSEEM6436HCL10NC 8606
CONZERV EM6433H A+ Power & Energy Meter, Class accuracy 0.5, 01 RS485
EM6433H METSEEM6433HCL05RS 7005
port
CONZERV EM6433H A+ Power & Energy Meter, Class accuracy 1.0, 01 RS485
EM6433H METSEEM6433HCL10RS ; 6599
port
EM6459H CONZERV EM6459H VAF+ PF Digital Meter, Class accuracy 0.5, 01 RS485 port METSEEM6459HCL05RS 7442
EM6459H CONZERV EM6459H VAF+ PF Digital Meter, Class accuracy 1.0, 01 RS485 port METSEEM6459HCL10RS ; 6981
EM6459H CONZERV EM6459H VAF+ PF Digital Meter, Class accuracy 1.0 METSEEM6459HCL10NC 5453
¬&EW¬REFERENCES¬MAY¬NOT¬BE¬THE¬EXACT¬EQUIVALENT¬0LEASE¬CONTACT¬LOCAL¬SALES¬REPRESNENTATIVE¬BEFORE¬ORDERING
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 226
Stay on top of it
with PowerTag
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 227
?1$%
/ !"2
2
6.3 Smartlink
> Compliance to IEC/EN 61131-2
> Protection Monitoring – Device Status and alarm notifications
> Load Control / Switching through Contactors and Impulse Relays
> Energy Monitoring through pulse meters
> Alarm over email and analog sensors (temperature / humidity) with
Smartlink Ethernet
> Plug & Play – Pre fabricated cables and in built web pages
> Rated Voltage: 24V DC
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 228
?1$%
/ !"2
2
\1]
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 229
16'N##
3
7
9
$%
#
Three phase CT Operated, Din Rail Meter / Direct Current-Three phase (upto 63A)
iEM 32xx Cl0.5S CT iEM 31xx Cl1.0 - Direct current
Product
Reference Unit LP [`] Reference Unit LP [`]
iEM 3x65 A9MEM3265 17486 A9MEM3165 16964
iEM 3x55 A9MEM3255 12256 A9MEM3155 13541
iEM 3x50 A9MEM3250 11492 A9MEM3150 12781
iEM 3x10 A9MEM3210 10528 A9MEM3110 11700
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 230
j1
>
%#
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 231
*12
[
2#
|2
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 232
11.2 DM 6100 Series – VAF, PF Meters
> Accuracy Cl0.5, Cl1.0
> DM6100 - VAF, PF meter
> DM6300 - VAF, PF meter with RS 485 port
0I1
`{
V3
V
#
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 233
Introducing
the world’s most accurate
Revenue meter with DLMS
MS
DL
PowerLogicTM&'j?G+6|#2
'
$%
z
and ABT Meter
Price On Request
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 234
VarPlus Box Xtreme
Built to perform in Xtreme
conditions
s¬ $ESIGNED¬FOR¬#¬OFFERS¬¬MORE¬LIFE¬THAN¬PRODUCTS¬DESIGNED¬
AT¬#
s¬ 4ESTED¬TO¬PERFORM¬¬HRS¬LIFE¬IN¬STANDARD¬OPERATING¬
conditions
s¬ 8TREME¬INRUSH¬WITHSTAND¬OF ¬¬X¬)N
s¬ $ESIGNED¬TO¬WORK¬IN¬8TREME¬ENVIRONMENTS
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 235
Power Factor Correction Products
Minimum
kVAr
Description Ordering Reference Unit LP [`]
Rating
Quantity (No.)
EasyCan (S Duty) 440V Range
MPP - Standard Duty Can 3Ph 1kVAr 440V 50Hz 1 3 MEHVCSDY010A44 ; 456
MPP - Standard Duty Can 3Ph 2kVAr 440V 50Hz 2 3 MEHVCSDY020A44 ; 634
MPP - Standard Duty Can 3Ph 3kVAr 440V 50Hz 3 3 MEHVCSDY030A44 ; 952
MPP - Standard Duty Can 3Ph 4kVAr 440V 50Hz 4 3 MEHVCSDY040A44 ; 1271
MPP - Standard Duty Can 3Ph 5kVAr 440V 50Hz 5 3 MEHVCSDY050A44 ; 1212
MPP - Standard Duty Can 3Ph 7.5kVAr 440V 50Hz 7.5 3 MEHVCSDY075A44 ; 1820
MPP - Standard Duty Can 3Ph 10kVAr 440V 50Hz 10 1 MEHVCSDY100A44 ; 2127
MPP - Standard Duty Can 3Ph 12.5kVAr 440V 50Hz 12.5 1 MEHVCSDY125A44 ; 2658
MPP - Standard Duty Can 3Ph 15kVAr 440V 50Hz 15 1 MEHVCSDY150A44 ; 3188
MPP - Standard Duty Can 3Ph 20kVAr 440V 50Hz 20 1 MEHVCSDY200A44 ; 4250
MPP - Standard Duty Can 3Ph 25kVAr 440V 50Hz 25 1 MEHVCSDY250A44 ; 5314
VarPlus Can (H Duty) 440V Range
MPP - Heavy Duty Can 3Ph 1kVAr 440V 50Hz 1 3 MEHVCHDY010A44 ; 609
MPP - Heavy Duty Can 3Ph 2kVAr 440V 50Hz 2 3 MEHVCHDY020A44 ; 953
MPP - Heavy Duty Can 3Ph 3kVAr 440V 50Hz 3 3 MEHVCHDY030A44 ; 1430
MPP - Heavy Duty Can 3Ph 4kVAr 440V 50Hz 4 3 MEHVCHDY040A44 ; 1906
MPP - Heavy Duty Can 3Ph 5kVAr 440V 50Hz 5 3 MEHVCHDY050A44 ; 1933
MPP - Heavy Duty Can 3Ph 7.5kVAr 440V 50Hz 7.5 3 MEHVCHDY075A44 ; 2901
MPP - Heavy Duty Can 3Ph 10kVAr 440V 50Hz 10 1 MEHVCHDY100A44 ; 3628
MPP - Heavy Duty Can 3Ph 12.5kVAr 440V 50Hz 12.5 1 MEHVCHDY125A44 ; 4536
MPP - Heavy Duty Can 3Ph 15kVAr 440V 50Hz 15 1 MEHVCHDY150A44 ; 5441
MPP - Heavy Duty Can 3Ph 20kVAr 440V 50Hz 20 1 MEHVCHDY200A44 ; 7256
MPP - Heavy Duty Can 3Ph 25kVAr 440V 50Hz 25 1 MEHVCHDY250A44 ; 9069
MPP - Heavy Duty Can 3Ph 30kVAr 440V 50Hz 30 1 MEHVCHDY300A44 ; 10882
MPP - Heavy Duty Can 3Ph 40kVAr 440V 50Hz (Single unit with IP00) 40 1 MEHVCHDY400A44 ; 14137
MPP - Heavy Duty Can 3Ph 50kVAr 440V 50Hz (Single unit with IP00) 50 1 MEHVCHDY500A44 ; 17672
VarPlus Can (GH Duty) 440V Range
MPP - Gas Heavy Duty Can 3Ph 5kVAr 440V 50Hz 5 3 MEHVCGSF050A44 ; 2040
MPP - Gas Heavy Duty Can 3Ph 7.5kVAr 440V 50Hz 7.5 3 MEHVCGSF075A44 3057
MPP - Gas Heavy Duty Can 3Ph 10kVAr 440V 50Hz 10 1 MEHVCGSF100A44 ; 3771
MPP - Gas Heavy Duty Can 3Ph 12.5kVAr 440V 50Hz 12.5 1 MEHVCGSF125A44 4711
MPP - Gas Heavy Duty Can 3Ph 15kVAr 440V 50Hz 15 1 MEHVCGSF150A44 ; 5652
MPP - Gas Heavy Duty Can 3Ph 20kVAr 440V 50Hz 20 1 MEHVCGSF200A44 ; 7538
MPP - Gas Heavy Duty Can 3Ph 25kVAr 440V 50Hz 25 1 MEHVCGSF250A44 ; 9421
MPP - Gas Heavy Duty Can 3Ph 30kVAr 440V 50Hz 30 1 MEHVCGSF300A44 ; 11300
MPP - Gas Heavy Duty Can 3Ph 40kVAr 440V 50Hz (Single unit with IP00) 40 1 MEHVCGSF400A44 14629
MPP - Gas Heavy Duty Can 3Ph 50kVAr 440V 50Hz (Single unit with IP00) 50 1 MEHVCGSF500A44 ; 18284
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 236
Power Factor Correction Products
Minimum
kVAr
Description Ordering Reference Unit LP [`]
Rating
Quantity (No.)
VarPlus Box Xtreme H Duty 440V Range NEW
MPP - Xtreme Heavy Duty Box 3Ph 5kVAr 440V 50Hz 5 1 MEHVBHDY050A44 ; 2552
MPP - Xtreme Heavy Duty Box 3Ph 7.5kVAr 440V 50Hz 7.5 1 MEHVBHDY075A44 3826
MPP - Xtreme Heavy Duty Box Box 3Ph 10kVAr 440V 50Hz 10 1 MEHVBHDY100A44 ; 4358
MPP - Xtreme Heavy Duty Box 3Ph 12.5kVAr 440V 50Hz 12.5 1 MEHVBHDY125A44 5457
MPP - Xtreme Heavy Duty Box 3Ph 15kVAr 440V 50Hz 15 1 MEHVBHDY150A44 ; 6547
MPP - Xtreme Heavy Duty Box 3Ph 20kVAr 440V 50Hz 20 1 MEHVBHDY200A44 ; 8727
MPP - Xtreme Heavy Duty Box 3Ph 25kVAr 440V 50Hz 25 1 MEHVBHDY250A44 ; 10910
MPP- Xtreme Heavy Duty Box 3Ph 30kVAr 440V 50Hz 30 1 MEHVBHDY300A44 13092
VarPlus Box Energy (MD-XL) 440V Range
Energy - MD-XL Box 3Ph 5kVAr 440V 50 Hz 5 1 MEHVBENY050A44 ; 4168
Energy - MD-XL Box 3Ph 7.5kVAr 440V 50 Hz 7.5 1 MEHVBENY075A44 6312
Energy - MD-XL Box 3Ph 10kVAr 440V 50 Hz 10 1 MEHVBENY100A44 ; 7959
Energy - MD-XL Box 3Ph 12.5kVAr 440V 50Hz 12.5 1 MEHVBENY125A44 9954
Energy - MD-XL Box 3Ph 15kVAr 440V 50 Hz 15 1 MEHVBENY150A44 ; 11925
Energy - MD-XL Box 3Ph 20kVAr 440V 50 Hz 20 1 MEHVBENY200A44 ; 15900
Energy - MD-XL Box 3Ph 25kVAr 440V 50 Hz 25 1 MEHVBENY250A44 ; 19906
VarPlus Box APP 440V Range
APP - Box 3Ph 5kVAr 440V 50Hz 5 1 MEHVBAPP050A44 ; 3772
APP - Box 3Ph 7.5kVAr 440V 50Hz 7.5 1 MEHVBAPP075A44 ; 5659
APP - Box 3Ph 10kVAr 440V 50Hz 10 1 MEHVBAPP100A44 ; 6619
APP - Box 3Ph 12.5kVAr 440V 50Hz 12.5 1 MEHVBAPP125A44 ; 8275
APP - Box 3Ph 15kVAr 440V 50Hz 15 1 MEHVBAPP150A44 ; 9931
APP - Box 3Ph 20kVAr 440V 50Hz 20 1 MEHVBAPP200A44 ; 13241
APP - Box 3Ph 25kVAr 440V 50Hz 25 1 MEHVBAPP250A44 ; 16551
APP - Box 3Ph 30kVAr 440V 50Hz 30 1 MEHVBAPP300A44 19897
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 237
Power Factor Correction Products
¬2EFER¬TO¬3ELECTION¬CHART¬FOR¬2EACTORS¬¬#APACITORS¬AVAILABLE¬ON¬PAGE¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 238
Power Factor Correction Products
¬2EFER¬TO¬3ELECTION¬CHART¬FOR¬2EACTORS¬¬#APACITORS¬AVAILABLE¬ON¬PAGE¬
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 239
Power Factor Correction Products
MPP - Xtreme Heavy Duty Box 3Ph 6.9kVAr 525V 50Hz 6.9 1 MEHVBHDY069A52 3007
MPP - Xtreme Heavy Duty Box 3Ph 12.5kVAr 525V 50Hz 12.5 1 MEHVBHDY125A52 5437
MPP - Xtreme Heavy Duty Box 3Ph 13.8kVAr 525V 50Hz 13.8 1 MEHVBHDY138A52 6013
MPP - Xtreme Heavy Duty Box 3Ph 15.4kVAr 525V 50Hz 15.4 1 MEHVBHDY154A52 6710
MPP - Xtreme Heavy Duty Box 3Ph 20.6kVAr 525V 50Hz 20.6 1 MEHVBHDY206A52 ; 8978
MPP - Xtreme Heavy Duty Box 3Ph 25kVAr 525V 50Hz 25 1 MEHVBHDY250A52 ; 10910
MPP - Xtreme Heavy Duty Box 3Ph 27.5kVAr 525V 50Hz 27.5 1 MEHVBHDY275A52 11994
MPP - Xtreme Heavy Duty Box 3Ph 30.6kVAr 525V 50Hz 30.6 1 MEHVBHDY306A52 13304
MPP - Xtreme Heavy Duty Box 3Ph 33.1kVAr 525V 50Hz 33.1 1 MEHVBHDY331A52 ; 14439
MPP - Xtreme Heavy Duty Box 3Ph 37.7kVAr 525V 50Hz 37.7 1 MEHVBHDY377A52 16390
VarPlus Box Energy (MD - XL) 525V Range
Energy - MD-XL Box 3Ph 6.9kVAr 525V 50 Hz 6.9 1 MEHVBENY069A52 5745
Energy - MD-XL Box 3Ph 12.5kVAr 525V 50 Hz 12.5 1 MEHVBENY125A52 10038
Energy - MD-XL Box 3Ph 13.8kVAr 525V 50 Hz 13.8 1 MEHVBENY138A52 10989
Energy - MD-XL Box 3Ph 20.6kVAr 525V 50 Hz 20.6 1 MEHVBENY206A52 16379
Energy - MD-XL Box 3Ph 25kVAr 525V 50 Hz 25 1 MEHVBENY250A52 19892
Energy - MD-XL Box 3Ph 30.6kVAr 525V 50 Hz 30.6 1 MEHVBENY306A52 24337
Energy - MD-XL Box 3Ph 33.1kVAr 525V 50 Hz 33.1 1 MEHVBENY331A52 ; 26314
Energy - MD-XL Box 3Ph 37.7kVAr 525V 50 Hz 37.7 1 MEHVBENY377A52 30269
VarPlus Box APP 525V Range
APP - Box 3Ph 6.9kVAr 525V 50Hz 6.9 1 MEHVBAPP069A52 5198
APP - Box 3Ph 12.5kVAr 525V 50Hz 12.5 1 MEHVBAPP125A52 8276
APP - Box 3Ph 13.8kVAr 525V 50Hz 13.8 1 MEHVBAPP138A52 9133
APP - Box 3Ph 15.4kVAr 525V 50Hz 15.4 1 MEHVBAPP154A52 10192
APP - Box 3Ph 17.2kVAr 525V 50Hz 17.2 1 MEHVBAPP172A52 11406
APP - Box 3Ph 20.6kVAr 525V 50Hz 20.6 1 MEHVBAPP206A52 ; 13641
APP - Box 3Ph 22.6kVAr 525V 50Hz 22.6 1 MEHVBAPP226A52 15137
APP - Box 3Ph 25kVAr 525V 50Hz 25 1 MEHVBAPP250A52 ; 16557
APP - Box 3Ph 27.5kVAr 525V 50Hz 27.5 1 MEHVBAPP275A52 18211
APP - Box 3Ph 30.6kVAr 525V 50Hz 30.6 1 MEHVBAPP306A52 20497
APP - Box 3Ph 33.1kVAr 525V 50Hz 33.1 1 MEHVBAPP331A52 ; 21917
APP - Box 3Ph 37.7kVAr 525V 50Hz 37.7 1 MEHVBAPP377A52 25253
Refer to Selection chart for Reactors & Capacitors available on page 245
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 240
VarPlus MAX
Detuned Reactors
MAXimize Efficiency
MAXimize Savings
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 241
$>6
N
Minimum
kVAr
Description Ordering Reference Unit LP [`]
Rating
Quantity (No.)
VarPlus MAX Detuned Reactor 5.7%, 440V Range
VarPlus MAX AL Detuned reactor 5 kVAr 440V 5.7 % 50Hz 5 1 LVR05050A44LO 10549
VarPlus MAX AL Detuned reactor 10 kVAr 440V 5.7 % 50Hz 10 1 LVR05100A44LO 15249
VarPlus MAX AL Detuned reactor 12.5 kVAr 440V 5.7 % 50Hz 12.5 1 LVR05125A44LO 17438
VarPlus MAX AL Detuned reactor 15 kVAr 440V 5.7 % 50Hz 15 1 LVR05150A44LO 19118
VarPlus MAX AL Detuned reactor 20 kVAr 440V 5.7 % 50Hz 20 1 LVR05200A44LO 20292
VarPlus MAX AL Detuned reactor 25 kVAr 440V 5.7 % 50Hz 25 1 LVR05250A44LO 18760
VarPlus MAX AL Detuned reactor 50 kVAr 440V 5.7 % 50Hz 50 1 LVR05500A44LO 31371
VarPlus MAX AL Detuned reactor 100 kVAr 440V 5.7 % 50Hz 100 1 LVR05X00A44LO 63649
VarPlus MAX Detuned Reactor 7%, 440V Range
VarPlus MAX AL Detuned reactor 5 kVAr 440V 7% 50Hz 5 1 |{N++G+3UU|& ; 9114
VarPlus MAX AL Detuned reactor 10 kVAr 440V 7% 50Hz 10 1 |{N+0++3UU|& ; 13172
VarPlus MAX AL Detuned reactor 12.5 kVAr 440V 7% 50Hz 12.5 1 |{N+0@G3UU|& ; 15062
VarPlus MAX AL Detuned reactor 15 kVAr 440V 7% 50Hz 15 1 |{N+0G+3UU|& ; 15972
VarPlus MAX AL Detuned reactor 20 kVAr 440V 7% 50Hz 20 1 |{N+@++3UU|& ; 16953
VarPlus MAX AL Detuned reactor 25 kVAr 440V 7% 50Hz 25 1 |{N+@G+3UU|& ; 14945
VarPlus MAX AL Detuned reactor 50 kVAr 440V 7% 50Hz 50 1 |{N+G++3UU|& ; 26189
VarPlus MAX AL Detuned reactor 75 kVAr 440V 7% 50Hz 75 1 |{N+G+3UU|& ; 40848
VarPlus MAX AL Detuned reactor 100 kVAr 440V 7% 50Hz 100 1 |{N+++3UU|& ; 52909
VarPlus MAX Detuned Reactor 14%, 440V Range
VarPlus MAX AL Detuned reactor 10 kVAr 440V 14 % 50Hz 10 1 LVR14100A44LO 14152
VarPlus MAX AL Detuned reactor 15 kVAr 440V 14 % 50Hz 15 1 LVR14150A44LO 24383
VarPlus MAX AL Detuned reactor 25 kVAr 440V 14 % 50Hz 25 1 LVR14250A44LO ; 25933
VarPlus MAX AL Detuned reactor 50 kVAr 440V 14 % 50Hz 50 1 LVR14500A44LO ; 43256
VarPlus MAX AL Detuned reactor 100 kVAr 440V 14 % 50Hz 100 1 LVR14X00A44LO 89453
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 242
Introducing
VarPlus MAX Copper
Wound Reactors
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 243
>
!6
N
Minimum
kVAr
Description Ordering Reference Unit LP [`]
Rating
Quantity (No.)
Varplus Copper Detuned Reactor 5.7%, 440V Range
DetunedReactor CU 5kVAr 440V 5.7% 50Hz 5 1 LVR05050A44CU 11721
DetunedReactor CU 10kVAr 440V 5.7% 50Hz 10 1 LVR05100A44CU 17679
DetunedReactor CU 12.5kVAr 440V 5.7% 50Hz 12.5 1 LVR05125A44CU 21902
DetunedReactor CU 15kVAr 440V 5.7% 50Hz 15 1 LVR05150A44CU 25010
DetunedReactor CU 20kVAr 440V 5.7% 50Hz 20 1 LVR05200A44CU 26546
DetunedReactor CU 25kVAr 440V 5.7% 50Hz 25 1 LVR05250A44CU 26676
DetunedReactor CU 50kVAr 440V 5.7% 50Hz 50 1 LVR05500A44CU 44607
DetunedReactor CU 100kVAr 440V 5.7% 50Hz 100 1 LVR05X00A44CU 83264
Varplus Copper Detuned Reactor 7%, 440V Range
DetunedReactor CU 5kVAr 440V 7% 50Hz 5 1 LVR07050A44CU 10275
DetunedReactor CU 10kVAr 440V 7% 50Hz 10 1 LVR07100A44CU 16788
DetunedReactor CU 12.5kVAr 440V 7% 50Hz 12.5 1 LVR07125A44CU 19290
DetunedReactor CU 15kVAr 440V 7% 50Hz 15 1 LVR07150A44CU 20356
DetunedReactor CU 20kVAr 440V 7% 50Hz 20 1 LVR07200A44CU 21608
DetunedReactor CU 25kVAr 440V 7% 50Hz 25 1 LVR07250A44CU 24909
DetunedReactor CU 50kVAr 440V 7% 50Hz 50 1 LVR07500A44CU 42365
DetunedReactor CU 100kVAr 440V 7% 50Hz 100 1 LVR07X00A44CU 77808
Varplus Copper Detuned Reactor 14%, 440V Range
DetunedReactor CU 10kVAr 440V 14% 50Hz 10 1 LVR14100A44CU 20510
DetunedReactor CU 15kVAr 440V 14% 50Hz 15 1 LVR14150A44CU 30155
DetunedReactor CU 25kVAr 440V 14% 50Hz 25 1 LVR14250A44CU 39896
DetunedReactor CU 50kVAr 440V 14% 50Hz 50 1 LVR14500A44CU 66548
DetunedReactor CU 100kVAr 440V 14% 50Hz 100 1 LVR14X00A44CU 117020
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 244
2
\{3_{
]6
Application
Effective kVAr output of Selection of 480V capacitors Selection of 525V capacitors Selection of 525V capacitors
Detuned Filter @ 440V for 7%/ 5.7% detuned Reactor for 7%/ 5.7% detuned Reactor for 14% detuned Reactor
for 440V for 440V for 440V
5kVAr 7%/5.7% Reactor 5kVAr 7%/5.7% Reactor 5kVAr 14% Reactor + 6.9kVAr,
5
+ 5.6kVAr, 480VCapacitor + 6.9kVAr, 525V Capacitor 525VCapacitor
10kVAr 7%/5.7% Reacor 10kVAr 7%/5.7% Reacor 10kVAr 14% Reacor + 12.5kVAr,
10
+ 11.3kVAr, 480V Capacitor + 13.8kVAr, 525V Capacitor 525V Capacitor
12.5kVAr 7%/5.7% Reactor 12.5kVAr 7%/5.7% Reactor 12.5kVAr 14% Reactor + 15.4kVAr,
12.5
+ 14.4kVAr, 480V Capacitor + 17.2kVAr, 525V Capacitor 525V Capacitor
15kVAr 7%/5.7% Reactor 15kVAr 7%/5.7% Reactor 15kVAr 14% Reactor + 18.5kVAr,
15
+ 17kVAr, 480VCapacitor + 20.6kVAr, 525V Capacitor 525V Capacitor
20kVAr 7%/5.7% Reactor 20kVAr 7%/5.7% Reactor 20kVAr 14% Reactor + 25kVAr,
20
+ 22.4kVAr, 480VCapacitor + 27.5kVAr, 525V Capacitor 525V Capacitor
25kVAr 7%/5.7% Reactor 25kVAr 7%/5.7% Reactor 25kVAr 14% Reactor + 30.6kVAr,
25
+ 28.1kVAr, 480V Capacitor + 33.1kVAr, 525V Capacitor 525V Capacitor
50kVAr 7%/5.7% Reactor 50kVAr 7%/5.7% Reactor 50kVAr 14% Reactor + 2 x 30.6kVAr,
50
+ 2 x 28.1kVAr, 480V Capacitor + 2 x 33.1kVAr, 525V Capacitor 525V Capacitor
75kVAr 7%/5.7% Reactor 75kVAr 7%/5.7% Reactor 75kVAr 14% Reactor + 3 x 30.6kVAr,
75
+ 3 x 28.1kVAr, 480V Capacitor + 3 x 33.1kVAr, 525V Capacitor 525V Capacitor
100kVAr 7%/5.7% Reactor 100kVAr 7%/5.7% Reactor 100kVAr 14% Reactor + 4 x 30.6kVAr,
100
+ 4 x 28.1kVAr, 480V Capacitor + 4 x 33.1kVAr, 525V Capacitor 525V Capacitor
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 245
VarPlus Logic
APFC relay
z Automatic Initialization & sequence detection
z Measurement of Step kVAr & THDv up to 19th
z RS485 port as default feature
z 4 Quadrant measurement
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 246
Power Factor Correction Products
APFC Relays
No. Minimum Ordering
Description Reference Unit LP [`]
of Step Quantity (No.)
Varlogic APFC Relays - Classic Range
RT6 , 6 step, 440V, 5A 6 1 51207 ; 14953
RT8 , 8 step, 440V, 5A 8 1 51209 ; 19381
RT12 , 12 step, 440V, 5A 12 1 51213 ; 22485
VarPlus Logic APFC Relays - Advanced Range
VPL06, 6 step LCD Display , 90V - 550V 50/60Hz 1A/5A with RS485 6 1 VPL06N ; 33310
VPL12, 12 step LCD Display , 90V - 550V 50/60Hz 1A/5A with RS485 12 1 VPL12N ; 35968
Unit MRP
Nominal Reactive Power 440V Auxiliary Contacts Reference
[`]
LC1-DK - with Damping Resistors & Block of Early Make poles
12.5 kVar 1NO + 2NC ,#$&+
2935
16.7 kVar 1NO + 2NC ,#$'+
4120
20 kVar 1NO + 2NC ,#$,+
4630
25 kVar 1NO + 2NC ,#$-+
5080
33.3 kVar 1 NO + 2NC ,#$0+
11060
40 kVar 1NO + 2NC ,#$4+
15240
60 kVar 1NO + 2NC ,#$7+
17155
#Contactor recommended upto 6 steps. For over 6 steps it is recommended to use chokes
¬2EFERENCE¬TO¬BE¬COMPLETED¬BY¬ADDING¬COIL¬VOLTAGE¬CODE
Note: For ordering contactors with other coil voltages & frequencies, please add ` 190/- to the
unit price of the standard contactor of the same rating.
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 247
$%
>
{2
N
9
Safe
Achieves Target set PF 3ph simultaneous PSD
Reduces demand kVA Burst proof capacitors
Eliminates PF Penalty Detuned Reactors- No Harmonic Amplification
Highest output to steps ratio ”∂” Minimum switching transient
Fuel savings in DG
Quality of construction
Compliance to IEC 61921 and Indian Standards.
Stringent quality control measures
Best Engineering practices
Best thermal design for heat dissipation
ISO 9001 ISO 14001 IGBC Green building IEC ROHS REACH Indian Standards
ISO 50001 Gold medal
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 248
$%
>
{2
>N
>
{3N
Compliant UU+{7 0++0++
>2 G+<[ ++0+++ $U@
V C L V W 0 C 1 0 1 0 0 B 6 M
%
N
33>`
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 249
$%
>
{2
Note:
VarSet prices will be On Request
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 250
3
$>2
s¬ !LL¬IN¬ONE¬(ARMONICS¬0&¬,OAD¬UNBALANCE¬&LICKER
s¬ &ULLY¬SELECTABLE¬HARMONICS¬nd to 50th
s¬¬ &LEXIBLE¬#4¬CONNECTION¬,OAD¬SIDE¬SOURCE¬SIDE
s¬¬ 3UITABLE¬TO¬WORK¬IN¬(ARSH¬ENVIRONMENT¬INCLUDING¬MARINE¬APPLICATION
s¬¬ 0ARALLEL¬CONNECTION¬UP¬TO¬¬UNITS¬
¬ANY¬COMBINATION¬OF ¬MODELS¬
s¬¬ 3TANDARDS¬COMPLIANCE¬¬CERTIlCATION¬ (UL508, CSA 22.2 No.14) CE Certified
s¬¬ 0#"!¬0ROTECTION¬
¬CONFORMAL¬COATING¬ON¬ALL¬0#"!S¬POLUTION¬$EGREE¬
<
&_ Marine Water Wastewater Processing plants Mining '
Airport <{3> <
\V
] plants
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 251
Accusine PCSn
Discover the new
AccuSine PCSn
Your 3-phase + neutral active harmonic filter
Clean up your current
z Units design to work in high ambient temp up to 50 Deg C
balancing
Please contact Customer Care Center for Stockable and Non stockable status of references.
; se.com/in
NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 252
3
<
2
32
$>2
Accusine PCS+
Minimum Ordering
Description AMPS Reference Unit LP [`]
Quantity (No.)
AccuSine PCS+
AccuSine PCS+ 60A 380V- 480V 50- 60Hz IP31 60 1 PCSP060D5IP31 On Request
AccuSine PCS+ 120A 380V - 480V 50- 60Hz IP31 120 1 PCSP120D5IP31 On Request
AccuSine PCS+ 200A 380V- 480V 50- 60Hz IP31 200 1 PCSP200D5IP31 On Request
AccuSine PCS+ 300A 380V- 480V 50- 60Hz IP31 300 1 PCSP300D5IP31 On Request
AccuSine PCSn
Clean up your current
zUnits design to work in high ambient temp up to 50 Deg C
z3 Level IGBT to meet tough target requirements from Utilities
z3-in-1 Harmonic Correction, PF improvement, Main current balancing
AccuSine PCSn
Minimum Ordering
Description AMPS Reference Unit LP [`]
Quantity (No.)
AccuSine PCSn
AccuSine PCSn 30A 208-415Vac 3ph+N chassis IP00 30 1 PCSN030Y4CH00 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N chassis IP00 60 1 PCSN060Y4CH00 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N chassis IP00 expansion module 60 1 PCSN060Y4CH00E On Request
AccuSine PCSn 30A 208-415Vac 3ph+N wall mount IP20 30 1 PCSN030Y4W20 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N wall mount IP20 60 1 PCSN060Y4W20 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N wall mount IP20 expansion module 60 1 PCSN060Y4W20E On Request
AccuSine PCSn 30A 208-415Vac 3ph+N rack mount 19" 30 1 PCSN030Y4R19 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N rack mount 19" 60 1 PCSN060Y4R19 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N rack mount 19" expansion module 60 1 PCSN060Y4R19E On Request
Please contact Customer Care Center for Stockable and Non stockable status of references.
; NORMAL STOCK ITEMS W.E.F. January 27, 2020
se.com/in 253
Note
Schneider Electric India Pvt. Ltd.
Corporate Office: 9th Floor, DLF Building No. 10, Tower C, DLF Cyber City, Phase II, Gurugram 122002 Haryana
Tel.: ++91 124 3940400 Fax: ++91 124 4222036/ 037
Customer Care Centre For more information, visit our website at: www.se.com/in
Monday-Saturday, 9 a.m. to 8 p.m. s¬ !LL¬0RICES¬ARE¬IN¬)NDIAN¬2UPEES
Toll-free numbers: 1800 419 4272, 1800 103 0011 s¬ 0RICES¬ARE¬SUBJECT¬TO¬CHANGE¬WITHOUT¬NOTICE
s¬ 0RICES¬CHARGED¬WILL¬BE¬AS¬PREVAILING¬ON¬THE¬DATE¬OF ¬DISPATCH
Email: customercare.in@se.com s¬ -AXIMUM¬2ETAIL¬0RICE¬-20 ¬IS¬INCLUSIVE¬OF ¬ALL¬TAXES
s¬ 4AX¬INCIDENCE¬ON¬INVOICES¬IS¬BASIS¬APPLICABLE¬'34¬RATES¬)NVOICE¬AMOUNT¬
not to exceed MRP.
s¬ )NVOICE¬!MOUNT¬¬-20¬n¬LESS¬!PPLICABLE¬DISCOUNT ¬¬!PPLICABLE¬'34¬
Distributor