Project Summary Report - HV Cable (Up To 33kV)
Project Summary Report - HV Cable (Up To 33kV)
Project Summary Report - HV Cable (Up To 33kV)
Project Description:
Installed Plant/Equipment
Plant Id/Cable No. Size Type Voltage (kV) Comments
Year of Installation:
phase:
non standard test
record of non standard
test acceptance: 0
new sheet name: not used
project name:
project number:
commissioning:
approval date:
sub name:
sub alpha:
commissioning stage:
stage description:
project description:
Customer:
User Entry:
Copy Tool Flag:
Test Verifications
Sheath Core
HV Cable Insulation Insulation H.V. SAT SIT Commissioning
Identifier Resistance Resistance Phase ID Withstand Checklist Checklist sign off
Sheath Core
HV Cable Insulation Insulation H.V. SAT SIT Commissioning
Identifier Resistance Resistance Phase ID Withstand Checklist Checklist sign off
Cable Details
Size: mm2 Rated Voltage: kV
Conductor: Length: m
Type: Source (from):
Insulation: Destination (to):
Cables/phase: Sheath Type:
Weather Conditions
Fine/Sunny Overcast Rain Temperature: ᵒC Humidity: %
Phase Identification
Instrument Used: Serial Number:
S Phase markings confirmed with Diode Box:
P OR
Verify correct phase markings by applying 500V DC with 2 phases joined and earthed.
IR Measurement at End 2
Phases Joined at End 1 A Phase B Phase C Phase
B+C+E MΩ MΩ MΩ
A+C+E MΩ MΩ MΩ Ensure adequate discharge time
between each test
A+B+E MΩ MΩ MΩ
Sheath Insulation Resistance ###
Instrument Used: Serial Number: ###
Insulation Resistance Test Voltage = kV
3 Phase Cables
3 x Single Phase Cables (or 1 x Single
Phase)
A phase sheath B phase sheath C phase sheath Sheath ###
Core/Cable 1 MΩ MΩ MΩ MΩ ###
Core/Cable 2 MΩ MΩ MΩ OR MΩ ###
Core/Cable 3 MΩ MΩ MΩ MΩ
Core/Cable 4 MΩ MΩ MΩ MΩ
Core/Cable 5 MΩ MΩ MΩ MΩ
Core/Cable 6 MΩ MΩ MΩ MΩ
Core Insulation Resistance
Instrument Used: Serial Number:
Insulation Resistance Test Voltage = kV
Select Test Method here (Read comments for details)
A to B+C+E B to A+C+E C to A+B+E
@1 min GΩ GΩ GΩ
Before HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
@1 min GΩ GΩ GΩ
After HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
Cable Details
Size: mm2 Rated Voltage: kV
Conductor: Length: m
Type: Source (from):
Insulation: Destination (to):
Cables/phase: Sheath Type:
Core/Cable 2
Core/Cable 2 A to B+C+E B to A+C+E C to A+B+E
@1 min GΩ GΩ GΩ
Before HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
@1 min GΩ GΩ GΩ
After HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
Core/Cable 3
@1 min GΩ GΩ GΩ
Before HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
@1 min GΩ GΩ GΩ
After HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
Core/Cable 4
@1 min GΩ GΩ GΩ
Before HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
@1 min GΩ GΩ GΩ
After HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
Core/Cable 5
@1 min GΩ GΩ GΩ
Before HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
@1 min GΩ GΩ GΩ
After HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
Core/Cable 6
@1 min GΩ GΩ GΩ
Before HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
@1 min GΩ GΩ GΩ
After HV Test @2 min GΩ GΩ GΩ
@5 min GΩ GΩ GΩ
Cable Details
Size: mm2 Rated Voltage: kV
Conductor: Length: m
Type: Source (from):
Insulation: Destination (to):
Cables/phase: Sheath Type:
Comments:
Signature Block:
Tested By: Name: Date:
Checked By: Name: Date:
Cable Details
Size: mm2 Rated Voltage: kV
Conductor: Length: m
Type: Source (from):
Insulation: Destination (to):
Cables/phase: Sheath Type:
Weather Conditions
Fine/Sunny Overcast Rain Temperature: ᵒC Humidity: %
High Voltage Withstand
Instrument Used: Serial Number:
Signature Block:
Tested By: Name: Date:
Checked By: Name: Date: