RCW Recloser Installation Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

TM

RCW
Pole mounted vacuum Recloser
Full gas filled protection, solid dielectric, vacuum interrupting technology

ANSI/IEEE C37.60/IEC 62271-111


(GB1984-2003 China standard)
GBT11022-1999 China Standard
IEC 6052
IEC 60255-11
IEC 60255-21-1 Class Ⅰ
IEC 60255-21-2 Class Ⅰ
IEC 60255-21-3 Class Ⅰ
IEC 60255-22-1 Class Ⅲ
IEC 60255-21-2 Class Ⅳ
IEC 60255-21-3 Class Ⅲ
IEC 60255-21-4 Class Ⅳ

Provided Customized manufacture


Whole solutions for design, assembly, test…

Recloser Installation Manual


Best solution for your power!
INTRODUCTION

High voltages.
Will cause death, serious injury and property damage.
Do not contact energized conductors.
De-energize and ground high voltage conductors before
working on or near them.

Heavy weight.
Can result in death, serious injury or property damage.
Obtain the services of a qualified rigger prior to hoisting the
recloser switch unit to assure adequate safety margins in the
hoisting equipment and procedures to avoid damage.

SIGNANL WORDS
The signal words "danger," "warning" and "caution" used in this manual indicate the
degree of hazard that may be encountered by the user. These words are defined as:
Danger - Indicates an imminently hazardous situation that, if not avoided, will result in
death or serious injury.
Warning - Indicates a potentially hazardous situation that, if not avoided, could result in
death or serious injury.
Caution - Indicates a potentially hazardous situation that, if not avoided, may result in
minor or moderate injury.
Caution (without safety alert symbol) -Indicates a potentially hazardous situation that, if
not avoided,
may result in property damage.

Field service operation and warranty issues:

ROCKWILL® can provide competent, well trained field service representatives to provide
technical guidance and advisory assistance for the installation, overhaul, repair and
maintenance of ROCKWILL® equipment, processes and systems.

ROCKWILL® service Tel: (86-577) 2786-9969


Or check the website information: http://www.auto-recloser-manufacturer.com/
● Summary
As the developing of the computer technology, transducer technology and network
communication, and advance of power system network working requirements, primary
equipment of single
function turn out the inconvenient when in the using of the network, According to the
whole power system, developing intelligent integration switch base on terminal it is
necessary.
Based on this idea, Our company developed a RCWTM Series intelligent integration
outdoor AC high voltage vacuum circuit recloser. (which is upgraded from outdoor
vacuum circuit breaker)
ROCKWILL® reclosers are all comply with relevant standards.
● Using condition
Air temperature: Maximum temperature: +85℃; Minimum temperature:-45℃
Humidity: Monthly average humidity 95%; Daily average humidity 90% .
Altitude above sea level: Maximum installation altitude: 2500m or more higher.
Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
No frequent violent shake
● Before using reminding
The RCWTM continues to be completely factory adjusted and sealed. A cable connector
assembly for interconnection wiring to the RCWTM switch is supplied.
Accessories such as a potential transformer, or surge arresters,
can be supplied as optional items.
● Optional accessories list
Products name and type Purpose Picture for reference
Standard
Potential transformer

11/0.22kV For electronic controller auxiliary


22/0.22kV power supply,
Normal secondary output voltage
33/0.22kV
is according to
11/0.11kV custom required. Burden 300VA.
22/0.11kV PT can be oil/dry type.
33/0.11kV
Standard
RSA-11DS1
Surge arrester

RSA-15DS1 For over voltage release


protection,
RSA-24DS1
Details is according to
RSA-30DS1 clients’ required
RSA-33DS1
RSA-36DS1
Special voltage sensor (6nos) Incoming&outgoing voltage measuring Inside of circuit breaker
Note:
As a required, Above equipment will be prepared by end-user.
● Equipment included with each recloser set
Three Phase RCWTM circuit breaker unit with 1 pcs Electronic controller RWK type

Hardware provision to connect ground Provided and visible


Cable assembly,26 pins cable, standard 6,8,12m Provided and visible
Manual trip Lever Provided and visible
Rubber insulation cap Provided and visible
● Transport, Lifting, flitting notice

Make sure follow below item to Flitting the Recloser switch and storage, and mounting.
Lifting of packing case
Transport
The RCWTM circuit-breaker is transported in seaworthy packing in ‘OPEN’ position.
The RCWTM circuit breaker is packed in one case normally with electronic control cabinet.
And the steel support fitting and others accessories is packed in the other case.
Following documents are packed with RCWTM breaker:
Instruction manual, Factory Test certificates, Drawings, Packing list.
The circuit- breakers shall be transported in packed condition only. Following precautions
are to be taken while transporting:
Ensure that packing cases are not placed on wet surfaces / waterlogged areas.
Breakers should not be stacked one over the other.

Receipt & Storage prior to installation


The breaker with complete packing should always be stored indoor to protect from direct
sunlight & rain/snow.
Breakers can be stored up to 3 months from date of shipment from the factory. For longer
storage, the packing needs to be removed and the breaker be kept under controlled
environmental conditions.
We define storage in controlled conditions as a place with:
Leak proof roof, Solid, flat ground, Relative humidity less than 50%,
Temperature 20°C (± 10° C).
Lifting of RCWTM circuit breaker
Flitting way make sure fasten one point
Make sure no much force for bushing

Note:
Very dangerous! Don’t allow to give much force on the bushing current transformer side.

● Interconnect with circuit breaker and electronic controller


Oil immersed

Ceramic pole Current transformers

Vacuum interrupter inside

D
E
A

Reference two side surge arrester

Mounting bracket (Provide:


Double pole installed
Single pole installed)

A 980mm For the voltage up to 27kV,


B 435mm it is better to adopt dry type PT
C 15kV/835mm 27kV/905mm 38kV1000mm
D 15kV/1125mm 27kV/1125mm 38kV/1175mm
E 15kV/360mm 27kV/360mm 38kV/435mm
F 155mm 255mm 330mm
G G 635mm
H 400mm

26 pins connector type H


3 Pins connector type T
26 pins connector hole H Connector hole for 3pins plug T
TM
Note 1: (RCW circuit breaker side definitions)
H type cable connector is prepared for 26 pins control cable to connect to electronic controller.
With 3 phase current signals
ON/OFF auxiliary signals
OPEN/CLOSE coils wires.
T type cable connector is prepared for 3 pins signal cable to connect to electronic controller.
With 3 phase voltage signals (Special required)
Note 2: (RWKTM type electronic controller side cable definition)
Main cable 26pins and 3 pins connect to RCW circuit breaker unit.
Plastic connector is prepared for PT auxiliary power incoming and RTU connection.
Both of the RCW circuit and controller has the grounding M12 bolt, Please link it to earth suitable.
● Normal operating for RCW recloser
High reliable manual opening device

Reliable manual opening device and ON/OFF indicator IP67 class waterproof plug connector
Visible outside ON/OFF indicator of RCW circuit breaker

in ON position In OFF position Controller shown ON/OFF light


Before using the controller, make sure the controller charged the power for at least 12 hours.
Note:
More question please consult with ROCKWILL®.
This manual is from ROCKWILL® copyright, If any modification will not give notice.