Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MilEffUM[ VOL:TAGE

MIETAL ENELOSED SWITDNCBOARD


Load Bmeak Swlteh W[th Vecuurm GlrrcuLt Bmeaken Gomblmatlon (PBA]

Load Break Switch With Vacuum Circuit Breaker Combination Type PBC is mainly used for protection tranformer,
distribution lines, etc. The basic unit is a equipped Vacuum Circuit Breaker . The breaker is rail mounted and fixed
or withdrawable type. To achieve the disconnecting function a 3-position Load Breakswjtch with an earthing switch
is mounted between busbar and the breaker.
lnspection of cable connections and fault indicators, when used, is easily carried out through the front-door windows.
The door is mechanically interlocked with the Load Break Switch eathing position to provide personal safety.
The switchgear is designed to be equipped with CT and VT.

. Rated Voltage
o Normal environment condition :

Cubicle operated in general indoor condition.


Ambient temperatur : Max. +4OoC
o Protection class
Cover of Switchgear : lP3X
o Busbar
Main Busbar : 6304 / t250A
Feeder : 6304
o Switchboard Color
Body : Plat Galvalum
Door : Orange / Gray White RAL 9902
o Standart Tvpe Test : IEC 62271-200 (2003-11)
o Rated Short time with stand current : 16kA / 1s
o Basic lnsulation Level (BlL) : 125kV
o Rated Frequency : 50/60 Hz

? Busbar
a Three position Load Break Switch
o Position lndicators for Load Switch
and Earting Switch
o Pressure meter For SF6 gas
(only one for each tank)
3lo
o Vacuum Circuit Breaker for Transformer /
Line Protection (Fixed/Drawout)
t ; o Shunt Trip Coil 24V / 48V DC,
F{* cB'DO, 630A
24 kV Ei r.ov / 22ov DC/AC
o Current Transformer
r Relay Protection OCR + GFR
r lndicator Phase
ffi r Anti Condensation Heater
. lntegrated low voltage compartment

ffi o Motorized 24V / 48V DC, LLOV / 22OV DC(AC


r Closing Coil24V / 48V DC, tl-.OV / 22OV DC/AC
o Voltage Transformer
o KWH Meter

PT. EGA TEKELINDO PRIMA


M
ELECTRICAL POWER SOLUTIONS
MffiEDIUMN V@LTAGE
ME:TAL EruGrcSED SWMHGB@ARD
Load tsmeak SwFteh WEth Vacuum Gf,mcuflt Bmeaker GombflmatEom (PtsGD

SWITCHGEAR DIMENSION

ffi

0llE

oK
\,-, llFor
t:

ffi
11,*.'r"$Sjil

ffi.ffi

ffi#H
Fr*#

o Width (mm) 750


o Depth (mm) 882

o Height (mm) 2000

ffi
ELECTRICAL POWER SOLUTIONS
Office :

Jl. Pangeran Jayakarta 141 Blok E. No.4.


Jakarta 10730 - lndonesia
Tel. : 6221' 6OO8O81 - 82 - 83 | 6221 6008742 - 43 - 45
Fax. : 6221 6293054 | Email : egatek@rad.net.id
Factory
Kawasan lndustri Jatake.
Jl. lndustri Raya lV Blok AE/7
Desa Bunder, Kecamatan CikuPa.
Tangerang 15L36 - lndonesia
: