Operating Instructions: Parallel Shaft Helical Gearboxes
Operating Instructions: Parallel Shaft Helical Gearboxes
Operating Instructions: Parallel Shaft Helical Gearboxes
INSTRUCTIONS
D Series
Parallel Shaft Helical Gearboxes
OIDCE0300-0418
Operating Instructions
D Series
Contents
Contents
2- Unit Designation....................................................................................................... 05
2.1 Detailed unit designation...................................................................................... 05
2.2 Nameplate unit designation................................................................................. 06
4- Safety......................................................................................................................... 17
4.1 Intended Use........................................................................................................ 17
4.2 Improper Use....................................................................................................... 17
4.3 Safety Instructions............................................................................................... 18
4.3.1 General Safety Instructions.................................................................... 18
4.3.1.1 Working on the gear reducer....................................................... 18
4.3.1.2 Operation.................................................................................... 18
4.3.1.3 Maintenance............................................................................... 18
4.3.1.4 Lubricant.................................................................................... 18
4.3.1.5 Ambient Conditions.................................................................... 18
4.4 Tightening Torques............................................................................................. 19
4.5 Case of Fire....................................................................................................... 19
4.5.1 Suitable extinguishing agents, protective equipment.......................... 19
4.5.2 Unsuitable extinguishing agents......................................................... 19
2
Operating Instructions
D Series
Contents
7- Mechanical Installation............................................................................................ 26
7.1 Installing customer shaft with shoulder............................................................... 27
7.2 Installing customer shaft without shoulder.......................................................... 28
7.3 Disassembling customer shaft with shoulder..................................................... 29
7.4 Disassembling customer shaft without shoulder............................................... 30
7.5 Shaft tightening torques...................................................................................... 31
7.6 Recommended shaft dimensions and disassembling nut dimensions................ 32
7.7 Dimensions of Splined Hollow Shaft to DIN 5480............................................... 33
7.8 Assembling customer shaft with shrink disk...................................................... 34
7.9 Disassembling customer shaft with shrink disk.................................................. 36
7.10 Assembling gear unit with torque arm.............................................................. 37
7.11 Fitting output shaft elements............................................................................. 40
7.12 Correct position of output shaft elements....................................................... 40
7.13 Fitting couplings................................................................................................. 41
9- Lubrication................................................................................................................ 43
9.1 Oil types............................................................................................................... 43
9.2 Changing the oil................................................................................................... 44
9.3 Mounting Positions............................................................................................... 45
9.4 Oil Quantities....................................................................................................... 46
11- Disposal.................................................................................................................. 52
11.1 Disposal of oil.................................................................................................... 52
11.2 Disposal of sealing............................................................................................ 52
11.3 Disposal of metal............................................................................................... 52
12- Appendix................................................................................................................. 53
12.2 Warranty conditions.......................................................................................... 54
12.3 Warranty............................................................................................................ 55
3
Operating Instructions
D Series
General Informations
1- How To Use This Manual
Take attention to the following safety and warning signs for proper understanding and quick reference.
Important Information.
EC Machinery Directive:
Within terms of the EC machinery directive 2006/42/EC, the gearboxes are considered
as not autonomous machine, but as a component to install in machines.
Operation is prohibited within the area of validity of the EC directive, until it has been
determined that the machine, in which this product is installed, corresponds to the regula-
tions within this directive.
The operating instruction must be kept close to the gearbox and must be available in
case it is needed.
This operating instruction is written for D series gear units and is applicable only for D
series. If any different type of gearbox is used please ask YILMAZ REDUKTOR for the
operating instructions of that type.
This instruction can be used only for standard type geared units of YILMAZ REDUKTOR.
For special application and modified gear units ask YILMAZ REDUKTOR for validity.
This manual does not cover 94/9/EC compatible gearboxes. For 94/9/EC contact YILMAZ
REDUKTOR.
4
Operating Instructions
D Series
Type Designation
2- Unit Designation
2.1- Detailed unit designation
Detailed D series gear units designation for ordering
(This Designation is different from the short nameplate designation)
Brake
L-220V With Fan
P-24V With Fan
S-220 V Without Fan
Z-24 V Without Fan
01-10 Nm 10-100 Nm
02-25 Nm 20-200 Nm
04-40 Nm 30-300 Nm
05-50 Nm 40-400 Nm
Number of poles
Motor size
Motor type
Output Shaft
00 :Hollow Shaft output
01 :Solid Shaft Output
02 :Solid shaft output with IEC B5 /14 Flange
03 :Flanged and Hollow Shaft output
0S :Shrink Disk Output
0E :Extruder Output
Stage
2 Stages
3 Stages 5 Stages
4 Stages 6 Stages
Revision Number
Housing Size
1...9
Input Type
R :With Motor
N :IEC B5 / B14 Flanged without Motor
V :IEC B5 / B14 Flanged with Motor
T :Without Motor
Gearbox Type
D Serie
5
Operating Instructions
D Series
Type Designation
YILMAZ REDÜKTÖR
www.yr.com.tr
MADE IN TURKEY
Type : DR473.03-90L/4
Serial N.: 100524545
Power : 1.5 kW Ratio: 121,49
Speed: 12 rpm. M. Pos.: M1
Oil: ISO VG320
(Mineral Oil)
Oil Qty : 6.4 lt.
Abreviations:
Serial N. : Serial Number
M.Pos. : Mounting Position
Type Designation;
DR473 - 3E71M/4C
Type Motor Size
6
Operating Instructions
D Series
Part Designation
3
3
Only Valid For 3 Stages
31 1
29
30
32
33 24 2
34
35 28
27
26
25 3
23
22 11
4
21 5
20 6 3
19
18 7
8
9
10
12
13
14
15
16
17
Standard D...00... type basic part diagram. Parts may differ for special applications.
2- Housing 10- Hollow Shaft 18- Closing Cap 26- Spacer 34- Circlip
3- Plug 11- Key 19- Circlip 27- Bearing 35- Closing Cap
7
Operating Instructions
D Series
Part Designation
30
31
33
34 25 2
35
36 29
28
27
26 3
24
23 11
4
22 5
21 12 6 3
20
19 7
8
9
10
13
14
15
16
17
18
Standard D...01... type basic part diagram. Parts may differ for special applications.
1- Pin Screw 9- Bearing 17- Circlip 25- Key 33- Shaft Gear
2- Housing 10- Output Shaft 18- Oil Seal 26- Gear 34- Bearing
3- Plug 11- Key 19- Closing Cap 27- Spacer 35- Circlip
4- Cover Plate 12- Key 20- Circlip 28- Bearing 36- Closing Cap
8
Operating Instructions
D Series
Part Designation
32
33
35
36 27 2
37
38 31
30
29
28 3
26
25 11
4
24 5
23 12 3
22
21 6
7
8
9
10
13
14
15
16
17
18
19
20
Standard D...02... type basic part diagram. Parts may differ for special applications.
1- Pin Screw 10- Solid Shaft 19- Flange 28- Gear 37- Circlips
2- Housing 11- Key 20- Bolt 29- Spacer 38- Closing Cap
3- Plug 12- Key 21- Closing Cap 30- Bearing
4- Cover Plate 13- Gear 22- Circlip 31- Spacer
5- Bolt 14- Spacer 23- Spacer 32- Bearing
6- Oil Seal 15- Bearing 24- Spacer 33- Gear
9
Operating Instructions
D Series
Part Designation
31
32
34
35 26 2
36
37 30
29
28
27 3
25
24 11
4
23 5
22 3
21
20 6
7
8
9
10
12
13
14
15
16
17
18
19
Standard D...03... type basic part diagram. Parts may differ for special applications.
1- Pin Screw 9- Bearing 17- Oil Seal 25- Shaft Gear 33- Key
10- Hollow
2- Housing 18- Flange 26- Key 34- Gear
Output Shaft
3- Plug 11- Key 19- Bolt 27- Gear 35- Bearing
20- Closing
4- Cover Plate 12- Gear 28- Spacer 36- Circlip
Cap
37- Closing
5- Bolt 13- Spacer 21- Circlip 29- Bearing
Cap
6- Oil Seal 14- Bearing 22- Spacer 30- Spacer
10
Operating Instructions
D Series
Part Designation
30
31
33 2
34 25
35 3
36 29
28
27
26 4
24
23 12
5
22 6
21 7 4
20
19 8
9
10
11
13
14
15
16
17
18
Standard D...0S... type basic part diagram. Parts may differ for special applications.
1- Pin Screw 9- Spacer 17- Circlip 25- Key 33- Shaft Gear
2- Shrink Disk 10- Bearing 18- Oil Seal 26- Gear 34- Bearing
3- Housing 11- Output shaft 19- Closing Cap 27- Spacer 35- Circlip
4- Plug 12- Key 20- Circlip 28- Bearing 36- Closing Cap
11
Operating Instructions
D Series
Part Designation
1
2
9 3
9 4
5
6
7
8
10
11
12
Standard D...0E... type basic part diagram. Parts may differ for special applications.
12
Operating Instructions
D Series
Part Designation
15
4
14
13
1
2
3
4
12
11
5
6
7
8
9
10
Standard D..4 type additional stage basic part diagram. Parts may differ for special
applications.
Parts List
13
Operating Instructions
D Series
Part Designation
N Type 2 and 3 stages are additional housing of D series 5 stages and 6 stages of gear
units.
34 35
36
37
33
38
Only Valid For 6 Stages
29
32
31
30
28
27
26 24
25 23
17 22
1
15 2
21 8
3
20 4
19 5
18 6
14
16 7
9
10
11
12
13
Standard N type 3 stages basic part diagram. Parts may differ for special applications.
Parts List
2- Oil plug 10- Bearing 18- Seal 26- Circlips 34- Bolt
3- Circlips 11- Circlips 19- Circlips 27- Bearing 35- Eye bolt
4- Bearing 12- Cover 20- Bearing 28- Gear 36- Oil plug
5- Spacer 13- Output Flange 21- Spacer 29- Key 37- Top side cover
6- Gear 14- Bolt 22- Gear 30- Gear 38- Screw Pin
7- Bearing 15- Key 23- Bearing 31- Bearing
8- Key 16- Output Shaft 24- Circlips 32- Circlips
14
Operating Instructions
D Series
Part Designation
10
Parts List 9
1- Shaft 6- Key
1
2- Circlips 7- Gear
2
3- Bearing 8- Circlips 3
4
4- Circlips 9- Nut
10
Parts List 9
1
1- Shaft 6- Seal
2
2- Circlips 7- Gear 3
4
3- Bearing 8- Circlips
4- Circlips 9- Nut
15
Operating Instructions
D Series
Part Designation
3.11- DT... Types Input Bearing Housing with Solid Input Shaft
Parts List
11 1
1- Seal 7- Circlips 10
2
2- Nut 8- Gear 3
4
3- Flange 9- Circlips
4- Shaft 10- Key
5
5- Bearing 11- Key 6
7
6- Bearing 8
9
16
Operating Instructions
D Series
Safety
4- Safety
The gear units are intended for industrial machines and may only be used in accordance
with the information provided in this manual the product catalogue and the nameplate of
the gearbox. They comply with the applicable standards and regulations and meet the
requirements of the directive 2006/42/EC. The gearbox must be started up, maintained
and operated according this manual. The gearbox most be incorporated with 2006/42/EC
confirming parts/machines.
A motor connected to the gear unit is only allowed to be operated in the frequency entries
so that the data provided on nameplate/catalogue of the gear unit is not exceeded and is ac-
cordance with the nameplate/catalogue. The speed range will be provided on the name plate
if YILMAZ REDUKTOR is informed that the gear unit will be used with frequency inverter.
If not informed the nameplate will have a single fixed speed and only this speed is allowed.
The electric motor and frequency inverter must be in accordance with 2006/42/EC.
If the gear units input is used with variable speed gear unit, this must be informed to YILMAZ
REDUKTOR before ordering and on the nameplate the allowed maximum and minimum
speeds (speed range) will be provided. If not mentioned by ordering the gear units speed
will be a fixed single input speed and only this speed is allowed.
If the gear unit will be driven by belt / coupling / chain drive etc. the gear unit is only allowed
to be used according the nameplate/catalogue entries. Different speed, higher motor power,
higher radial/axial loads etc. than nameplate/catalogue is not allowed.
The ambient temperature must be between +5 - +40 ºC and no abrasive media must attack
the paint and seals. If different working conditions this must be informed to YILMAZ before
ordering.
The gearbox maintenance (oil change / check ) must be done according this manual.
17
Operating Instructions
D Series
Safety
- Foreign bodies spinning through the air can cause grave injury.
Before putting the gear reducer into operation, check that there are no foreign bodies or
tools near the gear reducer
4.3.1.2- Operation
- Touching hot surfaces can lead to burns.
Do not touch the gear reducer if their operation temperatures are too high, or use suitable
safety equipment like gloves.
-Rotating machinery can lead to injuries. There is danger of being trapped or pulled in!
Keep a sufficient distance and make safeguarding to rotating machinery. See relevant norms
EN349+A1, EN13857.
4.3.1.3- Maintenance
-An unintentional start of the machine during maintenance work can lead to serious accidents.
Make sure no one can start the machine while you are working on it.
- Even a brief running of the machine during maintenance work can lead to accidents if the
safety devices are not operating.
Make sure that all safety devices are mounted and active.
4.3.1.4- Lubricant
- Extended, intensive contact with oils can lead to skin irritations.
Avoid extended contact with oil, and clean oil off skin thoroughly.
-If the gear unit will be used in outdoor applications the gear unit must be prevented from
rain snow and dust. Entering substances inside the gear unit from seals can damage the
gear unit. Observe the safety instructions for outdoor use EN12100:2010.
18
Operating Instructions
D Series
Safety
Bolt Tightenning
Class
Size Torque [Nm]
M8 8.8 23
M10 8.8 43
M12 8.8 77
19
Operating Instructions
D Series
Safety
If geared motors are used, please also refer to the manual of the motor manufacturer.
Before you install the gearbox you have to be sure that the gearbox is arrived with the all necessary
equipment and without damage. Points to take into consideration before you start to install the unit;
- You have received the correct operation manual of the your product.
- The gearbox and all its parts are transported without damage.
- The gearbox is stored correctly according the instructions in this manual
-You have the latest product catalogue or you have access to our web page
5.1- Transportation
When the goods arrive, first check for any damage. If some damage observed, immediately contact
the transport company and inform about the damage. Contact YILMAZ for the damage and do not
start to install the unit until it is agreed that the damage has no affect of operation.
Use the supplied eyebolts or lifting holes for lifting up the gear unit. The eyebolts are capable to
carry the weight of gearboxes only. Do not hang additional loads. Use suitable hoisting equipment
which is capable to hold the gear units weight. Refer to the catalogue for various types weights. See
drawing bellow for hoisting point.
Do not stay beneath / under the lifting/hoisting equipment which may cause serious injuries by falling
down objects, accidental movements, unexpected accidents.
20
Operating Instructions
D Series
Checking
5.2- Storage
If the geared unit or geared motor will be stored up to 3 years refer to the following in-
structions;
With Packing;
-Use corrosion protection oil for the output shaft and connection surfaces like flange sur-
face or foot assembling surface. Seal the unit in a plastic wrap and pack it in container.
A moisture indicator should be placed around the container to observe the moisture.
Relative atmospheric humidity should not exceed 50%. The container should be kept
under roof which protects from snow and rain. Under this condition the gear unit can be
stored up to 3 year with regular check. The ambient temperature should be between -5
to 60 ºC.
Without Packing;
-Use protection oil for the output shaft and connection surfaces like flange surface or
foot assembling surface. If no packing is used and the gearbox is stored without pack-
ing, the ambient temperature should be between 5 to 60 ºC. The gearbox must be kept
under enclosed roof with constant temperature and constant humidity not exceeding
50%. The storage should be free of dust and dirt and ventilated with filter. If the gearbox
is stored without packing it is recommended not to store more than 2 years and regular
check during this time is recommended.
- This manual is not for 94/9/EC (ATEX) conforming gear units. For 94/9/EC conforming
gear units refer to the ATEX range manual. ATEX conforming gear units have name
plates indicating the zone and the temperature class and are different from standard
type geared units. Therefore Standard units can not be installed on Potentially explosive
atmospheres.
21
Operating Instructions
D Series
Checking
In case of only gear unit is supplied from YILMAZ REDUKTOR please observe the name
plate of the electric motor and the instructions of the supplier. Check the basic electric con-
nection diagrams below. Use experienced electric technician.
Using wrong connection or voltage can damage the electric motor or environment.
22
Operating Instructions
D Series
Installing
The following wiring diagram is for standard 230/400 V 50 Hz AC electric motors. For dif-
ferent voltages please contact YILMAZ REDUKTOR. For gear units supplied without motor,
refer to the motor manufacturers user manual.
2 or 4 ≤ 3 kW ≥ 4 kW
6 ≤ 2,2 kW ≥ 3 kW
8 ≤ 1,5 kW ≥ 2,2 kW
L1 L2 L3 L1 L2 L3
U U U U
(230V) (230V) (400V) (400V)
U U
(230V) (400V)
I1 I2 I3 I1 I2 I3
V1
U2 V1
U
Uph=
Uph=U 3
I
3
V2
Iph=
W2
=I
U1 V2 I ph U2
W1
W2 W1 U1
W2 U2 V2 W2 U2 V2
U1 V1 W1 U1 V1 W1
L1 L2 L3 L1 L2 L3
23
Operating Instructions
D Series
Installing
Fren Bobini
Brake Coil Brake
Fren Coil
Bobini
M
3
M
3
Brake
Fren Coil
Bobini R S T N Brake
Fren Coil
Bobini
R S T N
3
M M
3
24
Operating Instructions
D Series
Installing
Do not mix synthetic oils with mineral oils which can cause serious damage on the gear unit.
Some plug positions are not machined according mounting position. If no mounting position
is mentioned by ordering, the standard M1 position plugs are machined.
Do not mix synthetic oils with mineral which can cause serious damage on the gear unit.
Abrasive material, chemicals, water, positive or negative pressure exceeding 0,2 bar can
affect or damage the sealing lip or output shaft. Inside entering substances from the seals
can cause serious damage to the gear unit.
25
Operating Instructions
D Series
Installing
7- Mechanical Installation
The gear unit can only be installed using the supplied connection points like foot and flange
assembling points.
To install the gear unit without the supplied connection points can cause serious injuries by
loosening or braking the gear unit. Even the gear unit is installed totally correctly according
this manual, be sure that no one will be harmed by accidentally brake downs or loosening.
The mounting plate must be rigid enough not allowing torsions, flat enough to prevent strains
by tightening the bolts and stable enough not allowing vibrations. By using chain drives this
becomes much more important because of the polygon effect on chain drives. According to
your connection elements the maximal permitted radial and axial load of the gear unit must
be in accordance with your application. Check the product catalogue for permitted radial
loads and calculation.
If the output or input shaft is overloaded by radial or axial loads it can cause serious damage
to the gear unit.
Cover all the turning parts from human entering or touching. Turning parts can cause severe
or fatal injuries.
26
Operating Instructions
D Series
Installing
1 2 3 4 5 6
1
23 1- Retaining Bolt
4 2- Lock Washer
3- Washer
4- Circlip
5- Hollow Shaft
6- Customer Shaft
5
27
Operating Instructions
D Series
Installing
1 2 3 4 5 6
1
23
4
1- Retaining Bolt
2- Lock Washer
3- Washer
4- Circlip
5- Hollow Shaft
5 6- Customer Shaft
28
Operating Instructions
D Series
Installing
1
23
4
5
6
7.3.2- Use the disassemble set from YILMAZ and fasten the bold as shown bellow to take
out the output shaft. For disassemble sets look the following pages.
1 2 3 4 5 6
1
2 1- Retaining Bolt
3 2- Circlip
4
3- Lock Washer
4- Washer
5- Hollow Shaft
6- Customer Shaft
29
Operating Instructions
D Series
Installing
1
2
3
4
5
5
6
7.4.2 -Use the disassembly set from YILMAZ and fasten the bold as shown bellow to take
out the output shaft. For disassembly sets look the following pages.
1 2 3 4 5 6
1
2 1- Retaining Bolt
3 2- Circlip
4
3- Lock Washer
4- Washer
5- Hollow Shaft
6- Customer Shaft
30
Operating Instructions
D Series
Installing
Tightining Torque
Type Bolt
[Nm]
D.072/073 M10 20
D.172/173 M10 20
D.272/273 M12 20
D.282/283 M16 40
D.372/373 M16 40
D.472/473 M16 40
D.572/573 M20 80
D.672/673 M20 80
31
Operating Instructions
D Series
Installing
b (max)
b1 b2 b3
f c
t
t1 h6
m1 Ød1 Ød
M
e1 e
45°
s u
g (DIN 332)
Type s u e1 t1 M d d1 m1 f b b1 b2 b3 c g h e t
D.87.. 109.7 20 116 27.5 M30 110 109 130 347 165 98 84 4 M24 52 116 28
D.97.. 119.7 20 127 31 M30 120 119 140 434 185 130 119 4 M24 52 127 32
Dismounting Mounting
6 Contour Bolt
(DIN ISO 4014 . DIN ISO 4017)
(DIN ISO 8765)
32
Operating Instructions
D Series
Installing
7.7- D.07.. - D.97.. DIMENSIONS OF SPLINED HOLLOW SHAFT TO DIN 5480
DIN5480
l4 l3
MxL
Ø da2
Ø df2
Ød1
Ød
Ød
l1 l2 l2 l1
l
l1 DIN 5480
g(DIN332)
Ød (h6)
Me
Dm l2 l3 l4
Me g
Type DIN5480 ød l1 l2 l3 l4 Dm
(Tolerances) (DIN332)
33
Operating Instructions
D Series
Installing
7.8.2- Use a solvent available in your market to clean all the dirt an oil from the shaft
and shrink disk hollow. The surfaces must be free from oil or any dirt. The solvent
must be removed from the surfaces as well.
34
Operating Instructions
D Series
Installing
7.8.3- Insert the shaft and tighten the bolts as shown. Be sure that there is a clear-
ance between the shrink disk shoulder and the hollow shaft shoulder of the gearbox.
1 2 3 4
1- Customer Shaft
2- Bronze Ring
3- Hollow Shaft
4- Shrink Disk
Tightening
Type Bolt Quantity
Torque [Nm]
D.07.. M5 6 4
D.17.. M6 5 12
D.27.. M6 7 12
D.28.. M6 8 12
D.37.. M6 8 12
D.47.. M6 10 12
D.57.. M8 7 30
D.67.. M8 7 30
D.77.. M10 9 59
D.87.. M12 10 100
D.97.. M12 12 100
35
Operating Instructions
D Series
Installing
36
Operating Instructions
D Series
Installing
Machine
Machine
37
Operating Instructions
D Series
Installing
7
6
5
4
4
1 23
2- Washer 5- Bolt
38
Operating Instructions
D Series
Installing
7.10.3- For the fixing bold position refer to the following dimensions
b
b1
h1 Ød
Type d b b1 h h1
D.07. 14 42 21 147 26.5
D.17. 17 54 27 158 31.5
D.27. 17 54 27 170 32
D.28. 17 54 27 198 40.5
D.37. 17 56 28 218 41
D.47. 22 80 40 278 50
D.57. 22 86 43 346 62
D.67. 26 110 55 395 70
D.77. 26 116 58 485 88
D.87. 32 160 80 550 110
D.97. 32 165 82.5 660 150
39
Operating Instructions
D Series
Installing
1) Hub
40
Operating Instructions
D Series
Installing
7.13.2- By fitting couplings be sure that there is no eccentric between the two shafts.
7.13.3- By fitting couplings be sure that the two shafts are not angular miss-aligned.
41
Operating Instructions
D Series
Maintenance and Inspections
Change Sealing x
Change Bearings x
45000
40000
Oil change interval [Hours]
35000
30000
Mineral
25000
Synthetic PAO
20000 Synthetic PG
15000
10000
5000
0
70 80 90 100 110 120 130 140 150 160
Oil bath temperature (Celcius)
For normal ambient conditions 70 ºC oil bath temperature should be taken as reference
* For D series mineral oil is used unless it is differently ordered. For oil type and quantities
refer to the following table.
42
Operating Instructions
D Series
Lubrication
9- Lubrication
9.1- Oil Types
Ambient Temperature Beyond Klüber
Aral Petroleum Castrol Lubrication Mobil Shell Total
[ºC]
Lubricant DIN ISO
51517-3 VG
Forced
Dip Lubri- Lubrica-
cation tion
Biodegra- Tribol
Klübersynth Carter
dable Oil CLP E -25 ... +40 +5 ... +40 320 – – BioTop – –
GEM 2-320 Bio 320
1418-320
Multis
Mineral Grease Aralub Energrease Spheerol Centoplex Mobilux Alvania
Complex
HL3 LS 3 AP3 2 EP EP 3 RL3
[ -20 .... +120 Working Temperature ºC] EP 2
Multis
Synthetic Grease Energrease Petamo Mobiltemp Cassida
– – Complex
SY 2202 GHY 133 N SHC 100 RLS 2
[ -30 .... +100 Working Temperature ºC] SHD 220
43
Operating Instructions
D Series
Lubrication
-Do not mix synthetic oils with mineral oils which will cause serious damage to the gear
unit. The oil change must be done by using the filling, draining and level plugs according
the mounting position illustrated in section 9.4.
44
Operating Instructions
D Series
Lubrication
9.3 Mounting Positions
M1
M2
M5
M4
M6
M3
M1
M5
M2
M4
M6
M3
45
Operating Instructions
D Series
Lubrication
9.4 Oil Plugs and Oil Quantities:
D Series 2-3 Stage Oil Level Plugs:
M1 M2 M3
M4 M5 M6
46
Operating Instructions
D Series
Lubrication
Oil Plugs and Oil Quantities
D Series 4 Stage Oil Level Plugs
A A
B A
B B
M1 M2 M3
B A
A B
B
A
M4 M5 M6
47
Operating Instructions
D Series
Lubrication
9.4 Oil Plugs and Oil Quantities:
D Series 5-6 Stage Oil Level Plugs:
B A
A A
B
B
M1 M2 M3
B A A
B
B
A
M4 M5 M6
48
Operating Instructions
D Series
Troubleshooting Guide
10- Troubleshooting Guide
All the operations bellow must be done by authorized and skilled mechanician/electrician.
Inform YILMAZ REDUKTOR before making any change to the gearbox. Only oil change is allowed
to change without information. Do not make any think if you are not sure what you are doing and
contact YILMAZ. Any change or operation done without the information of YILMAZ REDUKTOR is in
your own risk and responsibility and YILMAZ REDUKTOR does not take any responsibility.
You hear no noise and shaft Please Check the voltage supply and frequency of your electric
Gearbox Does Not is not turning. You are not connection. They must be in accordance with the nameplate of
001
Start Up using any driver or frequency the motor. Observe motor manufacturers start up manual. Still
inverter. does not work go to ID 100
You hear no noise and shaft Please observe the frequency incerter/driver manual. Chech
Gearbox Does Not
002 is not turning. You are using the motor by supplying direct voltage to see if the problem is on
Start Up
frequency inverter or driver. your driver/frequency inverter. Still does not work go to ID 001.
49
Operating Instructions
D Series
Troubleshooting Guide
For very low speeds the frequency inverters frequency is lowering down.
For very low frequencies the inverter parameter and motor parameter
Gearbox Does Not
must be optimized. Also for low speeds the efficiency of the gearbox may
006 Work in Low Speeds/ You are using
varry too much. Specially for worm-gearboxes. The recomended frequ-
frequencies. frequency inverter.
ency range is 20-70 Hz for worm-gearboxes and 10-70 Hz for Helical
Gear Boxes. Use Higher motor power and Frequency inverter or change
ratio of gearbox to work inside the reccomended range.
The oil is not in accordance with your working conditions. Change to lo-
Gearbox Does Not
007 Ambient Temperature wer viscosity oils. Observe this manuel for using the correct oil. Working
Start Mornings or Af-
is below +5 Celsius in higher ambient temperatures is an other solution if possible. If still
ter Long Time Stop.
same problem you need higher motor power.
Check Your moving parts for noise. Disassemble the gearbox and run
Noise is regular
011 Gearbox is noisy without load. If you still hear the noise motor bearings or gearbox bea-
continious
rings are defect. Change bearings. Goto ID 100
Check Your moving parts for noise. Disassemble the gearbox and run
012 without load. If you hear still the noise the oil may has some particles
Gearbox is noisy Noise is random
inside. Change the oil and look for small particles. If metal particles are
found the gearbox may have some demage. Goto ID 100
50
Operating Instructions
D Series
Troubleshooting Guide
ID Problem Observation Remedy
Check Your moving parts for noise. Disassemble the gearbox and
013 Gearbox is noisy Regular nocking noise run without load. If you still hear the noise one of the gears inside is
defect. Goto ID 100
Check the output-shaft connection alements for runout. Take out the
014 Gearbox is noisy Regular up and down noise output shaft element and run without load. If you still hear the noise
one of the gears has runout problem. Goto ID 100
Gearbox is with braked motor Low randomly clicking noise may come from the brake disk which is
015 Gearbox is noisy and noise is comming from the normal. If noise level is disturbing the brake may be defect or brake
brake side randomly. clearance is not adjusted. Goto ID 100
The frequency inverter parameters are not optimized for the frequ-
You are using frequency inver-
ency range or motor you are using. Observe the frequency inverters
016 Gearbox is noisy ter and the noise level is chan-
manual. If still same problem change the ratio of gearbox. Goto ID
ging according your speed.
100
If ambient Temp is over +40 Celsious or none stop work over 16
hours please change the top plug with a breather plug. Observe this
017 Oil is Leaking Oil Leakage from Seal
manual for using breather plug. If this is not your case the seal could
be damaged. Goto ID 100
If you are using breather plug be sure it is in the correct place. This
is the most top plug position according your mounting position. The
018 Oil is Leaking Oil Leakage from Plug plug may be not tight enough. There are some particles under the
plug rubber surface. Clean and tifgten the plug. If still same problem
goto ID 100
Observe exactly where the oil is comming out. It could be seal or
plug point where it comes out and leakes over the housing. If this is
019 Oil is Leaking Oil Leakage from Housing
your case goto ID 018/019. If you are sure oil comes out from hou-
sing than housing has some micro split / crack. Goto ID 100
Check the motor Fan Hub and rips. They must be free of dust. If you
023 Motor is heating are using forced external fan, check if it is working. If you are using
Ambient is dusty
up frequency inverter in low speeds and you do not have forced exter-
nal fan, you may need forced external fan. Goto ID 100
51
Operating Instructions
D Series
Troubleshooting Guide
11- Disposal
If your product is no longer of use and you wish to dispose of it, refer to the instructions here. If you
have any questions regarding ecological disposal methods, please consult our service points given on
the backside of this manuel.
11.1- Disposal of Oil
-Lubricants (oil and greases) are hazardous substances, which can contaminate soil and water.
Collect drained lubricant into suitable receptacles and dispose of it according to the valid national guid-
lines.
11.2- Disposal of Sealings
Remove the sealing rings from the gear reducer, and clean them of oil and grease resudies.
Dispose of the sealings as composite material (metal/plastic)
11.3-Disposal of Metal
Divide up the remainder of the gear reducer into iron, aluminium, non-ferrous havy metal if possible
Dispose of it according to the valid national guidelines.
52
Appendix
Warranty Conditions:
1. The geared motors and gear units are warranted for two year except the electric motor. For
motor warranty please refer to the manual of the electric motor manufacturer or the warranty
document of the motor manufacturer. This warranty is valid only if the gearbox is assembled
and started up according our operating instructions and is used under the allowed conditions
for the appropriate gearbox type in our catalogue. Special Gearbox parts made according
customer request are not covered by this warranty.
2. The warranty time starts from the start up time written on the warranty document and last
for two years. If the start-up time is more then three months after the billing time, the total
warranty time is limited to 27 months starting from billing time. If the warranty document is
not send to our company after start-up, the total warranty time will be limited to 24 months
after the billing time.
3. Any time during the warranty for maintenance, repair or change will be added to the war-
ranty time. This time starts from the date which the company or representative was made
aware of the problem and ends on the date of the re-start-up.
4. If the product fails to operate because of a manufacturing or assembly failure during the
warranty time, the product will be repaired free of charge.
5. If the product fails to operate because of a manufacturing or assembly failure during the
warranty time and it is not possible to repair it, the product will be changed with a new one
according to the report from our service department mentioning that the hazard can not be
repaired.
6. Costumers must inform the manufacturer if there are some problems after the service and
repair of the failed product.
7. The extra costs like stopped plant, physical or mental injuries etc. by the costumer side
are not covered by this warranty except the product itself.
8. The warranty is not valid if the user makes any modifications to the gear unit. e.g. Removal
of namepale, changing of any gear unit parts....
9. Yılmaz Redüktör delivers the repaired gear units to the first customer in the warranty pe-
riod. Yılmaz Redüktör will charge for delivery to the different addresses
YILMAZ REDUKTOR products are warranted for 2 (Two) years covering all parts
and materials used in products and their production errors unless they are started-
up and used according our service manual and is not modified or disassembled
without an acknowledgement from our company.
The warranty covers all costs like repair, service, spare parts etc. and no charge will
be asked under any name. The time for repair, service will be added to the warranty
time.
For detailed warranty conditions please refer the back side of this page.
Serial No:
Type:
Manufacturer:
Company : YILMAZ REDUKTOR Sanayi ve Ticaret A.S.
Ataturk Mah. Lozan Cad. No: 17 P.K.:34522 Kırac-Esenyurt-Istanbul/TURKEY
Phone: +90 (0) 212 886 90 00, Fax: +90 (0) 212 886 54 57
Name:
Billing Date/ Bill No.:
Start-Up Place / Date:
Address:
Phone - Fax:
International Services
If you call the above service point, you will be directed to our nearest service.