1 Motor 2 e
1 Motor 2 e
1 Motor 2 e
Lönne Group
The Lönne Group was founded in 1949 in Bergen and the present owner and
Chairman of the Board,
Terje Lönne took over the company in 1968. Since then the company specialized in
Electric Motors,
Gear Boxes, Transmissions and Bearings, and step by step became a leading Nordic
supplier within drive technology.
Besides still being a total supplier of high quality components, Lönne has developed
the business areas into enigneered
solutions and service. The competence is organized to serve all the Nordic countries
locally, at the same time as Lönne
keep up the strong reputation as an internationally experienced supplier of instant
and effective service
world wide.
Lönne Quality Management System Standards is certified for ISO 9001:2008
For further information, please have a look at our website or feel free to call us!
Certificates
Lönne motors can be delivered with following certificates according to EN 10204
Type 2.1: Declaration of compliance with the order
Document in which the manufacturer declares that the products supplied are in
compliance with the requirements of the order, without inclusion of test results.
Marine Classifications:
The most common Marine Classification Bureaus are: Det Norske Veritas,
Lloyd's Register of Shipping,ABS, Bureau Veritas, Germanisher Lloyd,
China Classification Society, Nippon Kaiji Kyokai.
Type Approval Certificates for Maritime Sector, please see page 47.
2
Electric Motors Chapter 1
Index
Page
3
Electric Motors Chapter 1
Electric motors are the most important type of electric load in New Efficiency Classes
industries within the Community where motors are used in the Different energy efficiency standard exists worldwide for
prosuction process. The systems in which these motors are asynchronous motors. To promote international harmonization, the
operated account for tabout 70% of the electricity consumed by international standard IEC 60034-30:2008 (Rotating electrical
the industry. There is a total potential for cost- effective machines- Part 30:Efficiency classes of single speed, three phase,
improvement of the energy efficiency of these motor systems by case- induction motors (IE code)) was created. This groups low-
about 20% to 30%. One of the major factors in such improvements voltage asynchronous motors into new efficiency classes (Valid
is the use of energy efficient motors. Concequently, motors in since October 2008). The Efficiency of IEC 60034-30:2008 are
electric motor systems represent a priority product for which based on losses determined in accordance with IEC
ecodesign requirements should be established. 60034-2-2:2007 standard. this has been valid since November 2007
and will replace the previous standard IEC 60034-2:1996 as of
Lönne has a long record of successful solutions within drive and November 2010. The supplementary losses are now measured and
motion technology. no longer added as percentage.
With the new measuring method, the supplementary losses are no longer applied as percentage (0,4%), but instead they are determined with
measurements (IEC 60034-2-1:2007). The nominal effeciencies are therefore reduced from EFF1 to IE2 and from EFF2 to IE1, even though there
have been no technical or physicl changes to motors.
Background information .
The EuP directive (Energy Using Products) is implemented in the national laws of EU memeber countries. The framework conditions for the
European directives have already been agreed. EU Directive 2005/32/ EC (=EuP Directive) is based on IEC 60034-30:2008 with regard to the
minimum efficiency values.This directive is implemented in European countries under a form of Energy Using Product Directive.
4
Electric Motors Chapter 1
5
Electric Motors Chapter 1
Energy- saving motors with "high efficiency" IE2 according to IEC 60034-30
Technical data for standard execution, S1- duty, IP55, 2- Pole and 4- Pole Motors
Type Output RPM Torque. Amp. Eff. Efficiency η [%] Kg
2- Pole Motors
9AA 80M02K 0,75 0,86 2870 3444 2,5 1,71 1,71 IE2 77,4 77,4 0,82 9,8
9AA 80M02 1,1 1,3 2860 3432 3,7 2,25 2,25 IE2 79,6 79,6 0,89 12,3
9AA 090S02 1,5 1,75 2890 3468 5 3,05 3,05 IE2 81,3 81,3 0,87 15
9AA 90L02 2,2 2,55 2890 3468 7 4,4 4,4 IE2 83,2 83,2 0,87 18,6
1TZ9 A 100L-2 3 3,45 2905 3486 10 6,1 6,1 IE2 84,6 85 0,84 21
1TZ9 A 100L-2 a) 4 4,6 2905 3486 13 7,8 7,8 IE2 85,8 86,3 0,86 26
1TZ9 A 112M-2 4 4,6 2950 3540 13 7,8 7,8 IE2 85,8 86 0,86 27
1TZ9 A 112M-2 a) 5,5 6,3 2950 3540 18 10,3 10,3 IE2 87 86,7 0,89 34
1TZ9 A 132S-2 5,5 6,3 2950 3540 18 10,4 10,4 IE2 87 87,5 0,87 39
1TZ9 A 132S-2 7,5 8,6 2950 3540 24 14,2 14,2 IE2 88,1 88,6 0,87 43
1TZ9 A 132M-2 a) 11 12,6 2955 3546 36 20 20 IE2 89,4 90 0,89 57
1TZ9 A 160M-2 11 12,6 2955 3546 36 20,5 20,5 IE2 89,4 89,5 0,87 67
1TZ9 A 160M-2 15 17,3 2945 3534 48 27 27 IE2 90,3 90,3 0,88 75
1TZ9 A 160L-2 18,5 21,3 2955 3546 60 33,5 33,5 IE2 90,9 91,2 0,88 84
1TZ9 A 160L-2 a) 22 25,3 2955 3546 71 39 39 IE2 91,3 91,7 0,89 94
16BG 183-2MA-- 22 24,5 2955 3555 71 39,5 38,5 IE2 91,3 92 0,88 170
16BG 206-2MA-- 30 33,5 2960 3560 97 53,5 52 IE2 92 92,1 0,88 220
16BG 207-2MA-- 37 41,5 2960 3560 119 65 63 IE2 92,5 92,7 0,89 250
16BG 223-2MA-- 45 51 2965 3565 145 79 78 IE2 92,9 92,9 0,88 300
16BG 253-2MB-- 55 62 2970 3570 177 96 94 IE2 93,2 93,3 0,89 380
16BG 280-2MB-- 75 84 2978 3578 241 133 128 IE2 93,8 93,5 0,87 500
16BG 283-2MB-- 90 101 2975 3575 289 157 151 IE2 94,1 94 0,88 570
16BG 310-2MB-- 110 123 2982 3582 352 187 184 IE2 94,3 94,2 0,9 750
16BG 313-2MB-- 132 148 2982 3582 423 220 215 IE2 94,6 94,5 0,91 915
16BG 316-2MB-- 160 184 2982 3580 512 265 260 IE2 94,8 94,9 0,92 960
16BG 317-2MB-- 200 224 2982 3580 640 330 320 IE2 95 95,2 0,92 1200
16BG 318 - 2MB 250 280 2986 3585 800 415 400 IE2 95 94,9 0,91 1280
16BG 312 - 2MA 315 353 2986 3586 1007 540 515 IE2 95 94,7 0,89 1355
kW kW 50Hz 60Hz Nm 50Hz 60Hz class. 100%load 75%load cos φ
4- Pole Motors 50Hz 60 hz 400V 460V 50Hz 400V 460V 50Hz 50Hz 50Hz 50Hz
IM 1001
9AA 8M04 0,75 0,86 1440 1728 5,1 1,81 1,8 IE2 79,6 79,6 0,75 12,3
9AA 90S04 1,1 1,3 1440 1728 7,3 2,55 2,55 IE2 81,4 81,4 0,77 15
9AA 90L04 1,5 1,75 1440 1728 9,9 3,4 3,4 IE2 82,8 82,8 0,77 18
1TZ9 A 100L-4 2,2 2,55 1455 1746 14 4,65 4,65 IE2 84,3 84,6 0,81 21
1TZ9 A 100L-4 3 3,45 1455 1746 20 6,2 6,2 IE2 85,5 85,9 0,82 25
1TZ9 A 100L-4 a) 4 4,6 1460 1752 26 8,3 8,3 IE2 86,6 86,6 0,8 30
1TZ9 A 112M-4 4 4,6 1460 1752 29 8,2 8,2 IE2 86,6 86,7 0,81 29
1TZ9 A 112M-4 a) 5,5 6,3 1460 1752 36 11,2 11,2 IE2 87,7 87,7 0,81 34
1TZ9 A 132S-4 a) 5,5 6,3 1465 1758 36 11,4 11,4 IE2 87,7 87,9 0,8 42
1TZ9 A 132M-4 7,5 8,6 1465 1758 49 14,8 14,8 IE2 88,7 89,2 0,83 49
1TZ9 A 132M-4 a) 11 12,6 1465 1758 72 21 21 IE2 89,8 89,8 0,84 64
1TZ9 A 160M-4 11 12,6 1470 1764 71 21 21 IE2 89,8 90,3 0,85 71
1TZ9 A 160L-4 15 17,3 1475 1770 97 28 28 IE2 90,6 90,8 0,85 83
1TZ9 A 160L-4 a) 18,5 17,3 1475 1770 120 34,5 34,5 IE2 91,2 91,2 0,85 100
16BG 183-4- MA-- 18,5 21,3 1470 1770 120 35,5 35 IE2 91,2 91,5 0,83 160
16BG 186-4MA-- 22 25,3 1465 1770 143 41,5 41 IE2 91,6 92 0,84 185
16BG 207-4MA-- 30 34,5 1475 1770 195 55 55 IE2 92,3 92,8 0,85 225
16BG 220-4MA-- 37 42,5 1470 1770 240 66 65,5 IE2 92,7 93,6 0,87 285
16BG 223-4MA-- 45 52 1475 1775 291 80 80 IE2 93,1 93,6 0,87 315
16BG 253-4MA-- 55 63 1480 1780 355 100 99 IE2 93,5 93,7 0,85 390
16BG 280-4MB-- 75 86 1485 1785 482 132 130 IE2 94 94,3 0,87 560
16BG 283-4MB-- 90 104 1486 1785 578 159 158 IE2 94,2 94,6 0,87 640
16BG 310-4MB-- 110 127 1490 1788 705 195 195 IE2 94,5 94,6 0,86 750
16BG 313-4MB-- 132 152 1488 1788 847 230 231 IE2 94,7 94,9 0,87 870
16BG 316-4MB-- 160 184 1488 1788 1027 280 275 IE2 94,9 95,2 0,87 950
16BG 317-4MB 200 230 1490 1788 1282 350 348 IE2 95,1 95,3 0,87 1120
16BG 328-4- MA 250 288 1488 1788 1605 435 430 IE2 95,1 95,2 0,87 1290
16BG 312-4MA 315 362 1488 1788 2022 560 550 IE2 95,1 94,9 0,86 1500
Additional data for 60Hz on request. Other Sizes and Voltages on request.
a) Increased rated output.
400
Formula for current with new voltage: I'n (new) = In (with 400V) •
U (new voltage)
6
Electric Motors Chapter 1
Energy- saving motors with "high efficiency" IE2 according to IEC 60034-30
Technical data for standard execution, S1- duty, IP55, 6- Pole and 8- Pole Motors
6- Pole Motors
9AA 90S06 0,75 0,86 925 1110 7,7 1,98 1,98 IE2 75,9 75,9 0,72 15,7
9AA 90L06 1,1 1,3 940 1128 11 2,9 2,9 IE2 78,1 78,1 0,7 19
1TZ9 A 100L-6 1,5 1,75 970 1164 15 3,7 3,7 IE2 79,8 79,8 0,73 25
1TZ9 A 100L-6 a) 2,2 2,55 965 1158 22 5,1 5,1 IE2 81,8 82,5 0,76 30
1TZ9 A 112M-6 2,2 2,55 965 1158 22 5,2 5,2 IE2 81,8 81,8 0,75 29
1TZ9 A 112M-6 a) 3 3,45 960 1152 30 6,6 6,6 IE2 83,3 83,4 0,79 34
1TZ9 A 132S-6 3 3,45 970 1164 30 7 7 IE2 83,3 83,3 0,74 38
1TZ9 A 132M-6 4 4,6 970 1164 39 8,7 8,7 IE2 84,6 84,6 0,78 43
1TZ9 A 132M-6 5,5 6,3 970 1164 54 12 12 IE2 86 86 0,77 52
1TZ9 A 132M-6 a) 7,5 8,6 970 1164 74 16,1 16,1 IE2 87,2 87,2 0,77 64
1TZ9 A 160M-6 7,5 8,6 975 1170 73 16,2 16,2 IE2 87,2 87,5 0,77 77
1TZ9 A 160L-6 11 12,6 975 1170 108 22,5 22,5 IE2 88,7 88,4 0,8 93
1TZ9 A 160L-6 a) 15 17,3 975 1170 147 30 30 IE2 89,7 89,9 0,81 115
16BG 186-6AA-- 15 18 975 1170 147 30 30 IE2 89,7 90,5 0,81 175
16BG 206-6AA-- 18,5 22 978 1174 181 36,5 36,5 IE2 90,4 91 0,81 210
16BG 207-6AA-- 22 26,5 978 1174 215 42,5 42,5 IE2 90,9 91,5 0,82 240
16BG 223-6AA-- 30 36 980 1176 292 57 57 IE2 91,7 92,2 0,83 325
16BG 253-6AA-- 37 44,5 980 1176 359 70 70 IE2 92,2 92,6 0,83 405
16BG 280-6AA-- 45 54 985 1182 435 82 82 IE2 92,7 92,9 0,85 420
16BG 283-6AB-- 55 66 988 1186 532 100 100 IE2 93,1 93,3 0,85 570
16BG 310-6AB-- 75 90 990 1188 723 139 139 IE2 93,7 93,7 0,83 760
16BG 313-6AB-- 90 108 990 1188 868 163 163 IE2 94 94,1 0,85 935
16BG 316-6AB-- 110 132 990 1188 1061 198 198 IE2 94,3 94,4 0,85 1010
16BG 317-6AB-- 132 158 990 1188 1273 235 235 IE2 94,6 94,6 0,85 1180
16BG 318-6AB-- 160 192 990 1188 1543 285 285 IE2 94,8 94,9 0,86 1245
16BG 312-6- MA 200 240 990 1190 1929 365 365 IE2 95 95,15 0,83 1395
400
Formula for current with new voltage: I'n (new) = In (with 400V) •
U (new voltage)
7
Electric Motors Chapter 1
2- Pole Motors
Technical data for standard execution, S1- duty, IP55
Output RPM Amp Eff
Type
kW kW 50Hz 60Hz Ist. Mst. Mmax Kg inertia
50Hz 60Hz n[%] cos φ
50Hz 60Hz 400V 440-480V In Mn Mn IM 1001 (kgm2)
7AA63M02K 0,18 0,21 2820 3420 0,51 0,5 63 0,82 3,7 2 2,2 3,5 0,000
7AA63M02 0,25 0,29 2830 3420 0,68 0,67 65 0,82 4 2 2,2 4,1 0,000
7AA63M02V a) 0,45 0,52 2720 3320 1,09 1,02 67 0,88 4,2 2 2,2 5,2 0,000
7AA71M02K 0,37 0,43 2740 3340 1 0,98 66 0,82 3,5 2,3 2,3 5 0,000
7AA71M02 0,55 0,63 2800 3400 1,36 1,32 71 0,82 4,3 2,5 2,6 6,6 0,000
7AA71M02V a) 0,94 1,08 2735 3290 2,3 2,2 73 0,82 4,7 3,1 2,6 7 0,001
7AA80M02K 0,75 0,86 2855 3455 1,73 1,68 73 0,86 5,6 2,3 2,4 8,2 0,001
7AA80M02 1,1 1,3 2845 3435 2,4 2,4 77 0,87 6,1 2,6 2,7 9,9 0,001
7AA80M02V a) 1,75 2 2840 3440 4 4 75 0,84 6,1 2,6 2,3 13 0,001
7AA90S02 1,5 1,75 2840 3460 3,25 3,2 78 0,85 5,5 2,4 2,7 12 0,002
7AA90S02V a) 2,9 3,35 2825 3425 6,3 6,3 81 0,83 6,6 3,4 3,7 16 0,002
7AA90L02 2,2 2,55 2880 3480 4,55 4,5 81 0,85 6,3 2,8 3,1 15 0,002
7AA90L02V a) 3,8 4,3 2810 3440 7,9 7,4 82 0,85 6 3,1 3,2 20 0,002
7AA100L02 3 3,45 2890 3490 6,1 5,9 84 0,85 6,8 2,8 3 21 0,004
7BA100L02 3 3,45 2890 3490 6,1 5,9 84 0,85 6,8 2,8 3 28 0,004
7AA100L02V a) 4,6 5,3 2880 3475 9,9 9,5 85 0,79 7,8 3,8 4,5 27 0,005
7BA100L02V a) 4,6 5,3 2880 3470 9,8 9,4 85 0,81 7,8 3,8 4,5 35 0,005
7AA112M02 4 4,6 2905 3505 7,8 7,6 86 0,86 7,2 2,6 2,9 29 0,006
7BA112M02 4 4,6 2905 3505 7,8 7,6 85 0,87 7,2 2,6 2,9 39 0,006
7AA112M02V a) 5,5 6,3 2900 3495 10,7 10,5 86 0,87 7,5 2,6 3,4 37 0,008
7BA112M02V a) 5,5 6,3 2900 3500 10,7 10,5 86 0,87 7,5 2,6 3,4 37 0,008
7AA132S02K 5,5 6,3 2925 3525 10,3 10,1 86,5 0,89 5,5 2 2,8 40 0,016
7BA132S02K 5,5 6,3 2895 3525 10,3 10,1 86 0,9 6,1 1,8 3,2 51 0,016
7AA132S02 7,5 8,6 2930 3530 13,8 13,5 87 0,89 6,3 2,3 3 48 0,021
7BA132S02 7,5 8,6 2930 3530 13,8 13,5 86,5 0,9 6,9 2,4 3,4 58 0,021
7AA132M02V a) 11 12,6 2905 3505 21,7 21 86 0,85 7,5 2,6 3,6 58 0,026
7BA132M02V a) 11 12,6 2900 3500 20,6 19,7 85 0,91 7,5 2,6 3,6 71 0,026
7AA160M02K 11 12,6 2940 3540 20 19,8 88 0,88 6 1,9 2,8 68 0,034
7BA160M02K 11 12,6 2940 3540 20,4 19,8 87 0,88 5,8 1,8 2,6 91 0,034
7AA160M02 15 17,3 2930 3530 26,5 26,5 88,5 0,9 6,4 2,2 3 76 0,04
7BA160M02 15 17,3 2940 3530 26,5 26,5 88,5 0,9 6,4 2,1 3 100 0,04
7AA160L02 18,5 21,3 2940 3540 32,5 32 90 0,91 7,1 2,6 3,4 87 0,052
7BA160L02 18,5 21,3 2940 3540 32,5 32 89 0,91 6,9 2,4 3,4 115 0,052
7AA160L02V a) 24,5 28 2920 3515 45,5 44 89 0,87 7,5 2,6 3,4 120 0,06
14BG183-2AA b) 22 24,5 2945 3535 40,5 40,5 91,6 0,86 6,4 2,5 3,4 145 0,068
14BG188-2AA a) b) 30 33,5 2950 3540 54 54 92,8 0,86 7,1 2,4 3,4 175 0,086
14BG206-2AA b) 30 33,5 2950 3540 54 54 91,8 0,88 6,5 2,3 3 205 0,129
14BG207-2AA b) 37 41,5 2955 3545 65 65 92,9 0,89 7,2 2,5 3,3 225 0,153
14BG208-2AA a) b) 45 51 2955 3545 78 78 93,6 0,89 6,9 2,5 3,2 255 0,182
14BG223-2AA b) 45 51 2960 3550 79 79 93,6 0,88 6,7 2,4 3,1 285 0,217
14BG228-2AA a) b) 55 62 2960 3550 94 94 94,8 0,89 7,3 2,6 3,2 335 0,266
14BG253-2AB b) 55 62 2970 3565 96 96 93,6 0,88 6,7 2,1 3,1 375 0,403
14BG258-2AA a) b) 75 84 2970 3565 130 130 94,5 0,88 7,1 2,4 3,1 420 0,483
14BG280-2AB 75 84 2975 3570 130 130 94,5 0,88 7,5 2,5 3,1 500 0,751
14BG283-2AB b) 90 101 2975 3570 154 154 95,1 0,89 7,2 2,6 3,1 540 0,832
14BG288-2AB a) b) 110 123 2975 3570 184 184 95,5 0,9 7 2,5 3 630 1
14BG310-2AB 110 123 2982 3580 190 190 94,6 0,88 7,2 2,4 3,1 720 1,19
14BG313-2AB b) 132 148 2982 3580 225 225 95,1 0,9 6,9 2,4 3 775 1,39
14BG316-2AB 160 180 2982 3580 265 265 95,5 0,91 7 2,4 3 900 1,62
14BG317-2AB 200 224 2982 3580 325 325 95,9 0,92 6,7 2,3 2,9 1015 2,09
14BG318-2AB a) 250 280 2982 3580 410 410 96 0,92 6,7 2,4 2,8 1230 2,46
14BG319-2AA a) 315 353 2988 3585 530 530 96,4 0,89 9,2 3,4 3,8 1355 2,78
LM355LY-2 355 390 2970 3560 594 568 95,8 0,9 7,3 1,6 2,2 1950 5,8
LM355XB-2 400 440 2975 3570 668 639 96 0,9 6,8 1,6 2 2180 5,3
LM355XC-2 450 495 2975 3570 752 719 96 0,9 6,8 1,6 2 2340 5,9
LM355XD-2 500 550 2975 3570 835 799 96 0,9 6,8 1,6 2 2520 6,4
LM 400XA2 560 616 2980 3576 936 895 96 0,9 7,2 1,2 2 3200 8,6
LM 400XB2 630 693 2980 3576 1052 1017 96 0,9 7,2 1,2 2 3490 9,6
LM 400XC2 710 781 2980 3576 1187 1187 96 0,9 7,2 1,2 2 3660 11
8
Electric Motors Chapter 1
4- Pole Motors
Technical data for standard execution, S1- duty, IP55
Output RPM Amp Eff
Type
kW kW 50Hz 60Hz Ist. Mst. Mmax Kg inertia
50Hz 60Hz n[%] cos φ
50Hz 60Hz 400V 440-480V In Mn Mn IM 1001 (kgm2)
7AA63M04K 0,12 0,14 1350 1650 0,42 0,41 55 0,75 2,8 1,9 2 3,5 0,000
7AA63M04 0,18 0,21 1350 1650 0,56 0,57 60 0,77 3 1,9 1,9 4,1 0,000
7AA63M04V a) 0,29 0,33 1330 1640 0,95 1 61 0,71 2,9 2,5 2,2 4,5 0,000
7AA71M04K 0,25 0,29 1350 1650 0,77 0,75 60 0,78 3 1,9 1,9 4,8 0,001
7AA71M04 0,37 0,43 1370 1670 1,05 1,04 65 0,78 3,3 1,9 2,1 6 0,001
7AA71M04V a) 0,6 0,69 1350 1655 1,6 1,5 70 0,79 4,1 2,4 2,1 7,4 0,001
7AA80M04K 0,55 0,63 1395 1695 1,45 1,41 67 0,81 3,9 2,2 2,2 8 0,002
7AA80M04 0,75 0,86 1395 1695 1,86 1,8 72 0,81 4,2 2,3 2,3 9,4 0,002
7AA80M04V a) 1,25 1,45 1340 1640 3,1 3,1 71 0,82 4,7 2,8 2,9 12 0,003
7AA90S04 1,1 1,3 1415 1715 2,55 2,55 77 0,81 4,6 2,3 2,4 12 0,003
7AA90L04 1,5 1,75 1420 1720 3,4 3,3 79 0,81 5,3 2,4 2,6 15 0,004
7AA90L04V 2,5 2,9 1380 1680 5,9 5,9 76 0,81 4,5 2,8 2,6 20 0,004
7AA100L04K 2,2 2,55 1420 1720 4,7 4,6 82 0,82 5,6 2,5 2,8 25 0,005
7BA100L04K 2,2 2,55 1420 1720 4,7 4,6 81 0,82 5,6 2,5 2,8 28 0,005
7AA100L04 3 3,45 1420 1720 6,4 6,2 83 0,82 5,6 2,7 3 26 0,006
7BA100L04 3 3,45 1410 1710 6,4 6,2 82,6 0,83 5,6 2,7 3 30 0,006
7AA100L04V a) 3,8 4,3 1400 1680 9,1 9,1 78 0,77 5,6 3 2,9 29 0,007
7AA112M04 4 4,6 1440 1740 8,2 7,9 85 0,83 6 2,7 3 32 0,011
7BA112M04 4 4,6 1440 1740 8,2 7,9 85 0,83 6 2,7 3 40 0,011
7AA112M04V a) 5,5 6,3 1440 1730 12,1 11,5 82 0,79 6,8 3 3 37 0,014
7BA112M04V a) 5,5 6,3 1435 1730 12,7 12,1 81 0,77 6,5 3,3 3,4 46 0,014
7AA132S04 5,5 6,3 1455 1755 11,4 10,9 86 0,81 6,3 2,5 3,1 42 0,018
7BA132S04 5,5 6,3 1455 1755 11,4 10,9 85,7 0,81 6,3 2,5 3,1 55 0,018
7AA132M04 7,5 8,6 1455 1755 15,2 14,7 87 0,82 6,7 2,7 3,2 49 0,024
7BA132M04 7,5 8,6 1455 1755 15,2 14,7 87 0,82 6,7 2,7 3,2 61 0,024
7AA132M04V a) 10 11,5 1440 1745 20,5 19,8 86 0,82 7,4 3,2 3,5 61 0,031
7BA132M04V a) 10 11,5 1440 1745 21 19,8 85 0,81 7 3,3 3,7 76 0,031
7AA160M04 11 12,6 1460 1760 21,5 21 88,5 0,84 6,2 2,2 2,7 76 0,04
7BA160M04 11 12,6 1460 1760 21,5 21 88,4 0,84 6,6 2,7 2,7 92 0,04
7AA160L04 15 17,3 1460 1760 28,5 28 90 0,84 6,5 2,6 3 79 0,052
7BA160L04 15 17,3 1460 1760 28,5 28 89,4 0,84 6,5 2,6 3 118 0,052
7AA160L04V a) 22 25,3 1455 1750 44 43 88 0,83 7,5 2,9 2,8 95 0,045
14BG183-4AA b) 18,5 21,3 1465 1760 35 35 90,4 0,84 6,7 2,4 3,1 140 0,099
14BG186-4AA b) 22 25,3 1465 1760 41,5 41,5 91 0,84 6,9 2,5 3,2 155 0,117
14BG188-4AA a) b) 30 34,5 1465 1760 59 59 91,7 0,8 6,3 2,6 2,9 180 0,144
14BG207-4AA b) 30 34,5 1465 1760 56 56 91,6 0,85 6,7 2,5 3,4 205 0,191
14BG208-4AA a) b) 37 42,5 1465 1760 70 70 92,5 0,83 6,5 2,6 3 230 0,234
14BG220-4AA b) 37 42,5 1475 1770 68 68 92,2 0,85 6,7 2,5 3,1 265 0,374
14BG223-4AA b) 45 52 1475 1770 81 81 93,1 0,86 7,2 2,7 3,2 300 0,447
14BG228-4AA a) b) 55 63 1475 1770 99 99 93,4 0,86 6,5 2,5 2,7 330 0,486
14BG253-4AA 55 63 1480 1775 100 100 93,5 0,85 6,1 2,4 2,8 390 0,688
14BG258-4AA a) b) 75 86 1482 1780 136 136 94,3 0,85 7 2,5 3 460 0,856
14BG280-4AA b) 75 86 1485 1780 136 136 94,2 0,85 7,1 2,5 3 535 1,19
14BG283-4AA b) 90 104 1485 1780 160 160 94,6 0,86 7,4 2,5 3 580 1,39
14BG288-4AA a) b) 110 127 1488 1785 198 198 95,2 0,84 7,9 2,8 3,3 680 1,71
14BG310-4AA 110 127 1488 1785 198 198 94,6 0,85 6,4 2,5 2,8 730 1,94
14BG313-4AA 132 152 1488 1785 235 235 95,2 0,85 6,8 2,7 2,9 810 2,31
14BG316-4AA 160 184 1486 1785 280 280 95,7 0,86 6,8 2,7 2,8 955 2,88
14BG317-4AA 200 230 1486 1785 340 340 95,9 0,88 6,5 2,6 2,8 1060 3,46
14BG318-4AA a) 250 288 1488 1785 430 430 96,1 0,87 7,7 3,1 3,2 1290 4,22
14BG319-4AA a) 315 362 1488 1785 550 550 96,3 0,86 7,3 3,3 3,1 1500 5,0
LM355XA-4 355 390 1485 1780 614 587 96 0,87 6,8 1,8 2 2150 9,5
LM355XB-4 400 440 1485 1780 691 661 96 0,87 6,8 1,8 2 2300 10,6
LM355XC4 450 495 1485 1780 778 744 96 0,87 6,8 1,8 2 2460 11,5
LM355XD-4 500 550 1485 1780 864 827 96 0,87 6,8 1,8 2 2720 12,8
LM400LX-4 560 616 1480 1785 946 905 96 0,89 7 1,3 2,8 3360 19,5
LM400XB-4 630 693 1490 1785 1064 1018 96 0,89 7 1,3 2,8 3430 18,5
LM400XC4 710 781 1490 1785 1194 1153 96 0,89 7 1,3 2,8 3620 21,1
9
Electric Motors Chapter 1
6- Pole Motors
Technical data for standard execution, S1- duty, IP55
Output RPM Amp Eff
Type
kW kW 50Hz 60Hz Ist. Mst. Mmax Kg inertia
50Hz 60Hz n[%] cos φ
50Hz 60Hz 400V 440-480V In Mn Mn IM 1001 (kgm2)
7AA63M06K 0,06 0,07 870 1080 0,33 0,32 39 0,66 2 1,8 1,8 3,5 0,000
7AA63M06 0,09 0,11 850 1070 0,47 0,46 42 0,66 2,2 1,8 1,5 4,1 0,000
7AA63M06V a) 0,12 0,14 890 1090 0,64 0,63 45 0,61 2,2 1,8 1,9 6,1 0,000
7AA71M06K 0,18 0,21 850 1050 0,72 0,67 54 0,68 2,3 2,1 1,9 6,3 0,001
7AA71M06 0,25 0,29 860 1060 0,79 0,77 61 0,76 2,7 2,2 2 6,3 0,001
7AA80M06K 0,37 0,43 920 1125 1,2 1,19 62 0,72 3,1 1,9 2,1 7,5 0,002
7AA80M06 0,55 0,63 910 1110 1,6 1,55 67 0,74 3,4 2,1 2,2 9,4 0,002
7AA90S06 0,75 0,86 915 1115 2,1 2 69 0,76 3,7 2,2 2,2 12 0,003
7AA90L06 1,1 1,3 915 1115 2,9 2,9 72 0,77 3,8 2,3 2,3 15 0,004
7AA100L06 1,5 1,75 925 1125 3,9 3,85 74 0,75 4,2 2,2 2,4 22 0,006
7BA100L06 1,5 1,75 930 1120 4 3,9 72 0,75 4,5 2,1 2,3 31 0,006
7AA112M06 2,2 2,55 940 1140 5,2 5,1 78 0,78 4,6 2,2 2,5 27 0,011
7BA112M06 2,2 2,55 940 1140 5,75 5,4 77 0,72 4,8 2,2 2,6 36 0,011
7AA112M06V a) 3 3,45 940 1140 7 6,8 80 0,78 4,8 2,4 2,4 28 0,015
7BA112M06V a) 3 3,45 930 1135 7,4 7,2 78 0,75 4,6 2,2 2,3 42 0,015
7AA132S06 3 3,45 950 1145 7,2 7,1 79 0,76 4,2 1,9 2,2 40 0,015
7BA132S06 3 3,45 950 1150 7,5 7,3 78 0,74 4,2 1,9 2,1 52 0,015
7AA132S06V a) 4 4,6 950 1150 9,4 9,2 80,5 0,76 4,5 2,1 2,4 48 0,019
7BA132S06V a) 4 4,6 950 1150 9,9 9,5 81 0,72 5 2,4 2,9 59 0,019
7AA132M06 5,5 6,3 950 1150 12,6 12,6 83 0,76 5 2,3 2,6 55 0,025
7BA132M06 5,5 6,3 950 1150 13,9 12,9 81 0,71 5,3 2,5 2,9 64 0,025
7AA160M06 7,5 8,6 960 1160 17 16,8 86 0,74 4,6 2 2,5 74 0,041
7BA160M06 7,5 8,6 960 1150 17,2 16,7 84 0,75 4,6 2 2,2 100 0,041
7AA160L06 11 12,6 960 1160 24,5 24,2 87,5 0,74 4,8 2,3 2,6 102 0,049
7BA160L06 11 12,7 960 1160 24,5 24,6 86 0,75 4,8 2,2 2,3 121 0,049
14BG186-6AA 15 18 965 1160 29,5 29,5 88,9 0,83 5,3 2,3 2,5 150 0,175
14BG188-6AA a) b) 18,5 22 970 1165 37,5 37,5 89,6 0,8 4,9 2,3 2,4 175 0,203
14BG206-6AA 18,5 22 975 1170 36,5 36,5 89,8 0,81 5,6 2,5 2,5 195 0,238
14BG207-6AA 22 26,5 975 1170 43,5 43,5 90,3 0,81 5,7 2,6 2,5 205 0,287
14BG208-6AA a) b) 30 36 975 1170 60 60 90,9 0,8 5,8 2,6 2,6 245 0,362
14BG223-6AA b) 30 36 978 1175 57 57 91,8 0,83 5,6 2,7 2,5 280 0,492
14BG228-6AA a) b) 37 44,5 978 1175 70 70 92,2 0,83 5,9 2,5 2,8 325 0,624
14BG253-6AA 37 44,5 980 1175 70 70 92,3 0,83 6 2,7 2,3 370 0,762
14BG258-6AA 45 54 982 1180 84 84 93,3 0,83 6,3 2,7 2,3 405 0,934
14BG280-6AA 45 54 985 1180 83 83 92,4 0,85 6,1 2,4 2,4 475 1,12
14BG283-6AA 55 66 985 1180 100 100 92,7 0,86 6,3 2,5 2,5 510 1,37
14BG288-6AA a) b) 75 90 985 1180 136 136 93,8 0,85 6,8 3 2,8 570 1,65
14BG310-6AA 75 90 988 1180 138 138 93,5 0,84 6,5 2,5 2,8 685 2,1
14BG313-6AA 90 108 988 1185 164 164 93,9 0,84 6,8 2,6 2,9 750 2,5
14BG316-6AA 110 132 988 1185 196 196 94,3 0,86 6,8 2,5 2,9 890 3,2
14BG317-6AA 132 158 988 1185 235 235 94,8 0,86 7,3 3,1 3 980 4,02
14BG318-6AA 160 192 988 1185 285 285 95 0,86 7,5 3 3 1180 4,71
14BG319-6AA 200 240 990 1185 355 355 95,5 0,85 7 2,8 2,9 1285 5,72
LM355L-6 250 275 990 1185 431 412 95,2 0,88 6,9 2 2 1900 11,1
LM355XB-6 315 347 990 1185 557 533 96 0,85 6,5 1,8 2 2310 13,5
LM355XC-6 355 391 990 1185 628 595 96 0,85 6,5 1,8 2 2490 14,3
LM355XD-6 400 440 990 1185 707 669 96 0,85 6,5 1,8 2 2630 15,4
LM400LX-6 450 495 990 1185 787 753 96 0,86 6,5 1,1 2,8 3820 28,8
LM400LY-6 500 550 990 1185 876 838 95,8 0,86 7,4 1,3 2,8 3970 31,4
LM400XC-6 560 616 990 1185 979 936 96 0,86 6,8 1,3 2,8 3660 28,8
LM450XA-6 630 693 995 1190 1119 1079 95,6 0,85 6,5 1,2 2,1 4700 45,1
LM450XB-6 710 781 995 1190 1246 1202 95,6 0,86 6,5 1,2 2,1 5100 48,6
10
Electric Motors Chapter 1
8- Pole Motors
Technical data for standard execution, S1- duty, IP55
Output RPM Amp Eff
Type
kW kW 50Hz 60Hz Ist. Mst. Mmax Kg inertia
50Hz 60Hz n[%] cos φ
50Hz 60Hz 400V 440-480V In Mn Mn IM 1001 (kgm2)
7AA63M08 0,06 0,07 630 795 0,46 0,43 32 0,6 2,2 1,9 1,7 6,3 0,001
7AA71M08K 0,09 0,1 630 780 0,36 0,35 53 0,68 2,2 1,9 1,7 6,3 0,001
7AA71M08 0,12 0,14 645 795 0,51 0,51 53 0,64 2,2 2,2 2 6,3 0,001
7AA71M08 0,18 0,21 610 780 0,95 0,82 48 0,61 1,9 1,9 2 6,5 0,001
7AA80M08K 0,18 0,21 675 830 0,75 0,75 51 0,68 2,3 1,7 1,9 7,5 0,002
7AA80M08 0,25 0,29 685 835 1,03 1 55 0,64 2,6 2 2,2 9,4 0,002
7AA90S08 0,37 0,43 675 825 1,13 1,1 63 0,75 2,9 1,6 1,8 10 0,003
7AA90L08 0,55 0,63 675 825 1,58 1,5 66 0,76 3 1,7 1,9 13 0,004
7AA90L08V 0,75 0,86 655 810 2,7 2,5 61 0,67 3,4 1,9 2,1 14 0,005
7AA100L08K 0,75 0,86 680 830 2,15 2,1 66 0,76 3 1,7 1,9 19 0,005
7BA100L08K 0,75 0,86 680 830 2,2 2,15 67 0,76 3 1,6 1,9 22 0,005
7AA100LO8 1,1 1,3 680 830 2,9 2,9 72 0,76 3,4 1,9 2,1 22 0,007
7BA100LO8 1,1 1,3 670 820 3 2,9 70 0,75 3,1 1,7 2 28 0,007
7AA112M08 1,5 1,75 705 855 3,85 3,8 74 0,76 3,7 1,8 2,1 24 0,013
7BA112M08 1,5 1,75 705 855 3,85 3,8 74 0,76 4.0 1,8 2,1 33 0,013
7AA112M08V a) 2,2 2,55 695 845 6,2 5,8 74 0,7 4,2 2,1 2,5 41 0,019
7BA112M08V a) 2,2 2,55 695 845 6,2 5,8 74 0,7 3,9 2,2 2,3 50 0,019
7AA132S08 2,2 2,55 690 840 6,3 6 75 0,69 3,9 1,9 2,3 53 0,014
7BA132S08 2,2 2,55 690 840 6,3 6 73 0,69 3,6 2 2,3 56 0,014
7AA132S08V a) 3 3,45 700 845 7,6 7,4 77 0,74 4,1 2,1 2,4 38 0,019
7BA132S08V a) 3 3,45 690 840 8,15 8,1 77 0,69 3,7 2,1 2,4 58 0,019
7AA132M08 3 3,45 700 845 7,6 7,4 77 0,74 4,1 2,1 2,4 55 0,019
7BA132M08 3 3,45 690 840 8,15 8,1 77 0,69 3,7 2,1 2,4 60 0,019
7AA132M08V a) 4 4,6 690 845 11,5 10,9 74 0,68 3,9 2,2 2,4 53 0,025
7BA132M08V a) 4 4,6 690 845 11,5 10,9 74 0,68 3,9 2,2 2,4 65 0,025
7AA160M08K 4 4,6 715 865 10 9,8 80 0,72 4,5 2,2 2,6 70 0,035
7BA160M08K 4 4,6 710 860 10,3 9,9 78 0,72 4,3 2 2,4 90 0,035
7AA160M08 5,5 6,3 710 860 13 12,8 83,5 0,73 4,7 2,3 2,7 70 0,043
7BA160M08 5,5 6,3 710 860 13,1 12,8 83 0,75 4,7 2,2 2,4 97 0,043
7AA160L08 7,5 8,6 715 865 17,6 17,4 85,5 0,72 5,3 2,7 3 91 0,062
7BA160L08 7,5 8,6 710 860 18,1 17,4 83 0,72 5,3 2,5 2,9 121 0,062
14BG186-8AB 11 13,2 725 870 25 25 87,5 0,73 4,2 1,7 2,1 150 0,169
14BG188-8AB a) b) 15 18 720 865 34 34 87,8 0,73 4,5 2 2,4 165 0,206
14BG207-8AB 15 18 725 870 32,5 32,5 87,7 0,76 4,9 2,2 2,6 205 0,29
14BG208-8AB a) 18,5 22 725 870 39 39 88,3 0,78 5,2 2,4 2,6 230 0,367
14BG220-8AB 18,5 22 730 875 38,5 38,5 89,4 0,78 5,5 2,3 2,7 270 0,482
14BG223-8AB 22 26,5 730 875 45 45 89,7 0,79 5,6 2,3 2,8 290 0,551
14BG228-8AB a) b) 30 36 730 875 61 61 90,4 0,79 5,6 2,6 2,8 340 0,658
14BG253-8AB 30 36 730 875 58 58 91,4 0,81 5,5 2,3 2,6 385 0,837
14BG258-8AB a) 37 44,5 730 875 71 71 91,9 0,82 5,6 2,4 2,6 430 1,06
14BG280-8AB 37 44,5 735 880 72 72 92 0,81 5 2,2 2,1 475 1,11
14BG283-8AB 45 54 735 880 87 87 92,4 0,81 5,1 2,2 2,1 515 1,35
14BG288-8AB a) 55 66 735 880 106 106 92,9 0,81 5,6 2,4 2,3 565 1,63
14BG310-8AB 55 66 740 885 106 106 93 0,81 5,8 2,2 2,6 680 2,08
14BG313-8AB 75 90 738 885 140 140 93,3 0,83 5,7 2,2 2,6 745 2,48
14BG316-8AB 90 108 738 885 168 168 93,4 0,83 5,8 2,2 2,7 865 3,14
14BG317-8AB 110 132 738 885 205 205 94 0,83 6,1 2,4 2,8 1020 3,95
14BG318-8AB a) 132 158 738 885 245 245 94,2 0,83 6,5 2,5 2,9 1100 4,52
14BG319-8AB a) 160 184 738 886 290 290 94,5 0,84 6,5 2,6 2,9 1325 4,8
LM355LX-8 200 220 745 890 367 351 94,8 0,83 6,5 1,8 2 2040 15,9
LM400M-8 250 275 745 890 469 449 95 0,81 6,9 1,4 2,6 2900 27,4
LM400L-8 315 347 745 890 563 539 95 0,85 6,5 1,3 2,6 3100 30,6
LM400LX-8 355 391 744 890 642 614 95 0,84 5,8 1,2 2,6 3250 32,4
LM400LY-8 400 440 743 890 715 684 95 0,85 5,7 1,1 2,6 3400 34,2
LM400XC-8 450 495 740 885 804 769 95 0,85 6 1,2 2,6 3760 29
LM450XA-8 500 550 745 890 945 908 95,5 0,8 6,8 1,2 1,8 4750 44,1
LM450XB-8 560 616 745 890 1058 1017 95,5 0,8 6,8 1,2 1,8 5215 49,5
LM450XC-8 630 693 745 890 1189 1144 95,6 0,8 6,8 1,2 1,8 5600 54,8
LM500XA-8 710 781 745 890 1315 1267 96 0,81 6 0,8 1,8 5750 70,1
11
Electric Motors Chapter 1
Technical data for standard execution, S1- duty, IP55, 440-480V 60Hz. ( Single winding – Dahlander )
Fan / pump duty Constant torque
Output AMP Output AMP
RPM RPM
Type kW (460) Type kW (460)
Low High Low High Low High Low High Low High Low High
7AA71M21- V 0,16 0,73 1692 3180 0,58 1,80 7AA63M21K 0,12 0,17 1596 3180 0,41 0,51
7AA80M21K- V 0,17 0,78 1680 3288 0,39 1,76 7AA63M21 0,17 0,22 1596 3240 0,51 0,58
7AA80M21- V 0,29 1,06 1662 3336 0,61 2,40 7AA71M21K 0,24 0,31 1650 3240 0,70 1,10
7AA90S21- V 0,38 1,57 1704 3402 0,78 3,50 7AA71M21 0,35 0,48 1656 3324 0,89 1,30
7AA90L21- V 0,58 2,24 1704 3402 1,08 4,80 7AA80M21K 0,55 0,67 1668 3372 1,25 1,60
7AA/ BA100L21K- V 0,75 2,80 1716 3438 1,44 5,40 7AA80M21 0,81 0,95 1668 3372 1,75 2,10
7AA/ BA100L21- V 0,92 3,47 1710 3432 1,70 7,00 7AA90S21 1,27 1,57 1668 3372 2,70 3,60
7AA/ BA112M21- V 1,27 4,93 1734 3462 2,50 10,7 7AA90L21 1,73 2,13 1668 3432 3,40 4,50
7AA/ BA132S21- V 1,67 6,61 1746 3504 3,00 12,8 7AA/ BA100L21K 2,30 2,69 1680 3456 4,25 5,50
7AA/ BA132M21- V 2,30 8,96 1746 3516 4,00 16,0 7AA/ BA100L21 2,99 3,47 1680 3420 5,50 7,60
7AA/ BA160M21- V 3,34 12,9 1746 3516 5,70 22,0 7AA/ BA112M21 4,26 4,93 1704 3462 8,00 10,5
7AA/ BA160L21- V 4,95 19,0 1746 3516 8,40 31,0 7AA/ BA132S21 5,41 6,61 1740 3504 9,70 12,5
14BG183-0BA 5,52 20,2 1758 3522 9,10 33,5 7AA/ BA132M21 7,48 9,00 1740 3516 13,6 16,7
14BG186-0BA 6,67 24,1 1764 3540 11,2 38,5 7AA/ BA160M21 10,7 12,9 1746 3516 18,3 23,4
14BG207-0BA 9,66 34,7 1770 3540 15,5 55,0 7AA/ BA160L21 15,0 19,0 1746 3516 25,6 32,0
14BG220-0BA 12,1 42,6 1770 3546 20,0 68,0 14BG183-0AA 17,3 20,2 1764 3528 28,0 33,5
14BG223-0BA 15,0 50,4 1770 3552 23,0 78,0 14BG186-0AA 20,7 24,1 1758 3528 33,5 38,5
14BG253-0BA 17,3 61,6 1776 3552 27,0 102 14BG207-0AA 29,9 34,7 1758 3540 48,0 55,0
14BG280-0BA 20,7 75,0 1788 3566 32,5 120 14BG220-0AA 36,8 42,6 1770 3546 58,0 69,0
14BG283-0BA 25,3 89,6 1788 3570 39,5 140 14BG223-0AA 43,7 50,4 1770 3552 68,0 78,0
14BG310-0BA 29,9 101 1790 3574 47,0 162 14BG253-0AA 52,9 61,6 1776 3552 84,0 102
14BG313-0BA 36,8 123 1790 3571 57,0 190 14BG280-0AA 72,5 84,0 1782 3558 112 134
14BG316-0BA 40,3 157 1790 3568 62,0 230 14BG283-0AA 84,0 97,4 1784 3570 130 155
14BG317-0BA 51,8 190 1790 3571 78,0 280 14BG310-0AA 97,8 112 1788 3571 156 182
14BG313-0AA 115 134 1786 3574 177 212
14BG316-0AA 138 162 1786 3571 209 242
14BG317-0AA 167 193 1788 3571 250 282
Technical data for standard execution, S1- duty, IP55, 380-420V 50Hz. ( Separate windings )
Fan / pump duty
Output AMP
RPM
Type kW (400)
Low High Low High Low High
7AA80M21- V2 0,20 0,75 1435 2820 0,60 1,90
7AA90L21- V2 0,25 1,10 1465 2865 0,87 2,30
7AA90L21- V2 0,30 1,50 1460 2810 0,93 3,10
7AA112M21- V2 0,45 2,20 1490 2950 3,45 5,70
7AA112M21- V2 0,75 3,00 1485 2925 3,50 6,70
12
Electric Motors Chapter 1
Technical data for standard execution, S1- duty, IP55, 440-480V 60Hz. (Separate windings )
13
Electric Motors Chapter 1
Technical data for standard execution, S1- duty, IP55, 440-460V 60Hz. (Single winding- Dahlander)
Technical data for standard execution, S1- duty, IP55, 380-420V 50Hz. ( Separate windings)
Fan / pump duty
Output AMP
RPM
Type kW (400)
Low High Low High Low High
7AA90L23 - V2 0,18 0,75 715 1445 1,40 2,20
7AA90L23 - V2 0,29 1,00 690 1420 1,50 2,60
7AA100L23 - V2 0,37 1,50 720 1455 2,10 4,10
7AA100L23 - V2 0,50 2,20 710 1435 2,50 5,40
7AA112M23 - V2 0,60 3,00 730 1445 3,30 6,70
7AA132S23 - V2 0,55 4,00 740 1465 2,80 8,80
7AA132M23 - V2 0,85 5,50 735 1455 3,70 10,8
7AA160M23 - V2 1,40 6,00 730 1475 5,00 13,2
7AA160L23 - V2 1,60 12,0 735 1465 5,60 24,3
400
Formula for current with new voltage: I'n (new) = In (with 400V) • Other voltages on request
U (new voltage)
14
Electric Motors Chapter 1
Standard motors from LÖNNE are characterized by their flexibility, ruggedness and energy efficiency.
In general, all motors are suitable frequency inverter- fed operation with line voltages up to 460V +10 %. The motors
are designed to fulfill the requirements of the European and International marked.
National standards
The motors comply with the IEC or European standard like 60034-1. The European standards replace the national
standards in the following countries: Germany (VDE), France (NF C), Belgium (NBNC), Great Britain (BS), Italy (CEI),
Netherlands (NEN), Sweden (SS), Switzerland (SEV). Etc.
The motors also comply with various national standards. The following standards (with the exception of non
standard motors) Have been harmonized with IEC publication 60034-1 or replaced with DIN EN 60034-1 so that the
motors can be operated at standard rated output.
-1 - cos φ
Power factor
6
Australia
AS 1359 (Higher output assignment than stated in DIN EN 50347 for frame size
250M and above)
15
Electric Motors Chapter 1
16
Electric Motors Chapter 1
17
Electric Motors Chapter 1
(IM1001- B3)
(IM3001- B5)
18
Electric Motors Chapter 1
19
Electric Motors Chapter 1
(IM1001- B3)
(IM3001- B5)
20
Electric Motors Chapter 1
80 9AA80M02K 125 30,5 150 163 100 118 50 80 8 200 120 9,5 13,5 273,5 299,5 M16/ M25
9AA80M 2,4 125 30,5 150 163 100 118 50 80 8 200 120 9,5 13,5 308,5 334,5 M16/ M25
90 9AA90S 2,4 140 30,5 165 180 100 143 56 90 10 218 128 10 14 331 382,5 M16/ M25
9AA90L 2,4 140 30,5 165 180 125 143 56 90 10 218 128 10 14 358 409,5 M16/ M25
100 1TZ9100L 160 42 196 198 140 176 63 100 12 266 166 12 16 395,5 428,5 M32
1TZ9100L* 160 42 198 198 140 176 63 100 12 266 166 12 16 430,5 463,5 M32
112 1TZ9112M 190 46 226 222 140 176 70 112 12 289 177 12 16 389 422 M32
1TZ9112M* 190 46 226 222 140 176 70 112 12 289 177 12 16 414 447 M32
132 1TZ9132S 216 53 256 262 140 218 89 132 15 334 202 12 16 465 500,5 M32
1TZ9132M 216 53 256 262 178 218 89 132 15 334 202 12 16 465 500,5 M32
1TZ9132M* 216 53 256 262 178 218 89 132 15 334 202 12 16 515 550,5 M32
160 1TZ9160M 254 60 300 314 210 300 108 160 18 396,5 236,5 15 19 604 638 M40
1TZ9160L 254 60 300 314 254 300 108 160 18 396,5 236,5 15 19 604 638 M40
1TZ9160L* 254 60 300 314 254 300 108 160 18 396,5 236,5 15 19 664 698 M40
180M 16BG183-2 279 65 340 364 241 328 121 180 20 442 262 15 19 720 810 M40
16BG183-4 279 65 340 364 241 328 121 180 20 442 262 15 19 670 760 M40
180L 16BG186-4,6,8 279 65 340 364 279 328 121 180 20 442 262 15 19 720 810 M40
200L 16BG206-2 & 6 318 70 380 402 305 355 133 200 25 500 300 19 25 720 810 M50
16BG207- 2 & 6 318 70 380 402 305 355 133 200 25 500 300 19 25 777 867 M50
16BG207- 4 & 8 318 70 380 402 305 355 133 200 25 500 300 19 25 720 810 M50
225S 16BG220- 4 & 8 356 80 436 445 286 361 149 225 34 550 325 19 25 790 890 M50
225M 16BG223-2 356 80 436 445 311 361 149 225 34 550 325 19 25 820 920 M50
16BG223-4,6,8 356 80 436 445 311 361 149 225 34 550 325 19 25 850 950 M50
250M 16BG253-2 406 100 490 495 349 409 168 250 40 642 392 24 30 890 990 M63
16BG253-4 406 100 490 495 349 409 168 250 40 642 392 24 30 960 1060 M63
16BG253- 6 & 8 406 100 490 495 349 409 168 250 40 642 392 24 30 890 990 M63
280S 16BG280-2 457 100 540 555 368 479 190 280 40 712 432 24 30 960 1070 M63
16BG280- 4,6,8 457 100 540 555 368 479 190 280 40 712 432 24 30 960 1070 M63
280M 16BG283-2 457 100 540 555 419 479 190 280 40 712 432 24 30 1070 1180 M63
16BG283-4 457 100 540 555 419 479 190 280 40 712 432 24 30 1070 1180 M63
16BG283-6 & 8 457 100 540 555 419 479 190 280 40 712 432 24 30 960 1070 M63
315S 16BG310-2 508 120 610 610 406 527 216 315 50 815 500 28 35 1072 1182 M63
16BG310-4,6,8 508 120 610 610 406 527 216 315 50 815 500 28 35 1102 1212 M63
315M 16BG313-8 508 120 610 610 457 527 216 315 50 815 500 28 35 1102 1212 M63
16BG313-2 508 120 610 610 457 578 216 315 50 815 500 28 35 1232 1342 M63
16BG313-4 & 6 508 120 610 610 457 578 216 315 50 815 500 28 35 1262 1372 M63
315L 16BG316-2 508 120 610 610 508 578 216 315 50 815 500 28 35 1232 1342 M63
16BG316- 4 & 6 508 120 610 610 508 578 216 315 50 815 500 28 35 1262 1372 M63
16BG316-8 508 120 610 610 508 578 216 315 50 815 500 28 35 1262 1372 M63
16BG317-8 508 120 610 610 508 578 216 315 50 815 500 28 35 1262 1372 M63
16BG317-2 508 120 610 610 508 666 216 315 30 815 500 28 35 1372 1482 M63
16BG317-4 & 6 508 120 610 610 508 666 216 315 30 815 500 28 35 1402 1512 M63
16BG318- 6 & 8 508 120 610 610 508 666 216 315 30 815 500 28 35 1402 1512 M63
16BG 318-2 508 120 610 610 508 648 216 315 50 815 500 28 35 1372 1517 -
16BG 312-2 508 120 610 610 508 648 216 315 50 815 500 28 35 1372 1517 -
16BG 318-4 508 120 610 610 508 666 216 315 50 815 500 28 35 1462 1607 -
16BG 312-4&6 508 120 610 625 508 666 216 315 30 815 500 28 35 1546 1691 -
16BG 312-8 508 120 610 625 508 666 216 315 30 815 500 28 35 1486 1631 -
21
Electric Motors Chapter 1
D- E-EA F- GD
Type 7JB A AA AB AC AD B BB C CA H HA HD HF K KA L LC LD LG W G- GB
DA FA - GF
66 202,5 232
63- M..K 63- M 100 27 120 118 94 80 96 40 63 7 164 77,5 7 10 69,5 75 11 23 4 8,5 4
92 228,5 258
71 112 30,5 132 139 94,5 90 106 45 83 71 7 182 87,5 7 10 240 278 63,5 75 14 30 5 11 5
94 273,5 324 M25X
80 80M02 125 30,5 150 156,5 103,5 100 118 50 80 8 200 96,5 9,5 13,5 63,5 75 19 40 6 15,5 6
137 316 366,5 1,5
143 331 389
90 90L02 140 30,5 165 173,5 109 100 143 56 90 10 218 105 10 14 79 75 24-19 50-40 8-6 20-15,5 7-6
186 374 432
100 160 42 196 196 138 140 176 63 100 12 263 123 12 16 425 102 120 28 60 8 24 7
22
Electric Motors Chapter 1
253, 5
63- M..K 63- M 100 27 120 118 99 94 80 86 40 63 7 64 77,5 7 10 69,5 75 M25X 1,5 11 23 4 8,5 4
279, 5
71 112 30,5 132 139 99,5 94,5 90 106 45 71 7 182 87,5 7 10 292 63,5 75 M25X 1,5 14 30 5 11 5
80 125 30,5 150 156,5 94 94 100 118 50 80 8 200 96,5 9,5 13,5 328 63,5 75 M25X 1,5 19 40 6 15,5 6
90 140 30,5 165 173,5 109 114 100 143 56 90 10 218 104,5 10 14 383 79 75 M25X 1,5 24 50 8 20 7
100 160 42 196 196 138 138 140 176 63 100 12 263 123 12 16 458 102 120 M25X 1,5 28 60 8 24 7
23
Electric Motors Chapter 1
Mounting Options
Standards
All Lönne- motors are manufactured according to norms as following standards:
acc. EN 60034-7
24
Electric Motors Chapter 1
25
Electric Motors Chapter 1
26
Electric Motors Chapter 1
Brakes
Design and mode of operation.
The brake takes the form of a single- disk brake with two friction via the armature disk against the friction surface by means of the
surfaces. springs. In the braked state there is a gap S Gap between the armature
disc and the solenoid component. To release the brake, the solenoid is
The braking torque is generated by friction when pressure Is applied by energized with DC voltage. The resulting magnetic force pulls the
one or more pressure springs in the deenergized state. armature disk against the spring force on to the solenoid component.
The brake is released electromagnetically. When the motor brakes, the The spring force is then no longer applied to the rotor which can rotate
rotor which can be axially shifted on the hub or the shaft, is pressed freely.
160 2LM8 260-8NA10 260 AC 230 / DC205 0.50 100 165 340 79 0.0073 129
180 2LM8 315-0NA10 315 AC 230 / DC205 0.56 100 152 410 79 0.0073 125
200 2LM8 400-0NA10 400 AC 230 / DC205 0.61 110 230 390 93 0.0200 137
225 2LM8 400-0NA10 400 AC 230 / DC205 0.61 110 230 390 93 0.0200 239
Type U230
Technical data:
max.input voltage 275V AC
max.DC current 1A
magnetic coil
27
Electric Motors Chapter 1
size 71 A=165mm 17.00.0062 66 0,10A / 28W 0,10A / 30W 0,05A / 30W 0,12A / 41W 0,10A / 33W 0,06A / 33W
size 80 A=166mm 17.00.0063 66 0,11A / 29W 0,10A / 31W 0,05A / 31W 0,13A / 44W 0,10A / 34W 0,06A / 34W
size 90 A=195mm 17.00.0064 66 0,25A / 71W 0,28A / 85W 0,16A / 85W 0,25A / 88W 0,26A / 90W 0,15A / 90W
size 100 A=200mm 17.00.0065 66 0,31A / 86W 0,35A / 100W 0,19A / 100W 0,29A / 79W 0,32A / 105W 0,18A / 105W
size 112 A=255mm 17.00.0654 66 0,26A / 73W 0,27A / 85W 0,15A / 85W 0,39A / 95W 0,28A / 94W 0,16A / 94W
size 132 A=252mm 17.00.0197 66 0,40A / 115W 0,45A / 138W 0,24A / 138W 0,31A / 107W 0,41A / 148W 0,24A / 148W
size 160 A=295mm 17.00.0181 66 0,96A / 236W 0,76A / 220W 0,43A / 220W 0,31A / 107W 0,94A / 284W 0,56A / 284W
size 180 A=320mm 17.00.0284 66 0,96A / 236W 0,76A / 220W 0,43A / 220W 0,59A / 185W 0,94A / 284W 0,56A / 284W
size 200 A=320mm 17.00.0283 66 0,96A / 236W 0,76A / 220W 0,43A / 220W 0,59A / 185W 0,94A / 284W 0,56A / 284W
3~Y 380-
3~D 220-290V 3~Y 380-500V 3~D 220-400V
690V
size 225 A=411mm 17.00.1088 66 0,87A / 335W 0,5A / 335W 0,87A / 355W 0,5A / 335W
size 250 A=435mm 17.00.1089 66 0,87A / 335W 0,5A / 335W 0,87A / 355W 0,5A / 335W
3~Y 380-
3~D 220-400V 3~Y 380-690V 3~D 220-400V
690V
size 280 A=449mm 17.00.1090 66 1,58A / 650W 0,91A / 650 1,58A / 650W 0,91A / 650
size 315 A=473mm 17.00.1091 66 1,58A / 650W 0,91A / 650 1,58A / 650W 0,91A / 650
DA
size 180 A=320mm 17.00.0284 120 320 168 50 350 311 860m3/ h
size 200 A=320mm 17.00.0283 115 320 168 55 390 311 950m3/ h
size 225 A=411mm 17.00.1088 194 411 216 65 424 385 1350m3/ h
size 250 A=435mm 17.00.1089 195 435 240 73 475 385 1500m3/ h
size 280 A=449mm 17.00.1090 205 449 249 73 525 480 2800m3/ h
size 315 A=473mm 17.00.1091 202 473 273 58 586 480 3200m3/ h
L + = Additional length to standard fan cover
28
Electric Motors Chapter 1
Type Design
Aluminium housing and terminal box, cast iron end shields and flanges. The terminal box
7AA100 - 160 cable entries are located in the terminal box cast on the frame. (The cable entry rotate by
180°) Foot mounted motors of frame size 112-160 are of bolt on design. (FS 100 on request).
Cast iron housing, end- shields and flanges. Cast iron terminal box(turnable 4x90°) Foot
7BA100 - 160
mounted motors of frame size 100-160 are of bolt on design.
Aluminium housing and terminal box(turnable 4x90°), aluminium end shields and B5 flange.
1TZ9 A Flange B14 cast iron.Snap in fancover in reinforced plastic. Frame for B5 motors are
delivered with option for bolt on design.
Cast iron housing, end- shields and flanges. Cast iron terminal box(turnable 4x90°) Frame
14BG/16GB 180-315 size 180 – 315 Plastic fan cover, metal as option. Motors in mounting form B5, can be
modified with bolt on feet.
355 - 400 Cast iron housing, end- shields and flanges. Cast iron terminal box(turnable)
Vibration severity grade Rated speed / rpm 56 < H ≤ 132 132 < H ≤ 225 225 < H ≤ 400 H > 400 H > 400
Note that the measured values can deviate by ± 10% from the actual values. The limits stated in the table are applicable to freely suspended
motors running uncoupled and at no load. For frequency inverter - fed operation with frequencies greater than 6oHz, special balancing is
required for compliance with the specified limit values.
(Max speed)
29
Electric Motors Chapter 1
Lubrication Quantity of
intervall(hours) Grease(gram)
7BA160 2 6309 C3 6309 C3 4000 h 20g
7BA160 2 to 8 6309 C3 6309 C3 8000 h 20g
14/16BG. Frame size 180 2 6310 C3 6310 C3 4000 h 20g
14/16BG. Frame size 180 4 to 8 6310 C3 6310 C3 8000 h 20g
14/16BG. Frame size 200 2 6312 C3 6312 C3 4000 h 20g
14/16BG. Frame size 200 4 to 8 6312 C3 6312 C3 8000 h 20g
14/16BG. Frame size 225 2 6313 C3 6313 C3 4000 h 20g
14/16BG. Frame size 225 4 to 8 6313 C3 6313 C3 8000 h 20g
14/16BG. Frame size 250 2 6315 C3 6315 C3 4000 h 25g
14/16BG. Frame size 250 4 to 8 6315 C3 6315 C3 8000 h 25g
14/16BG. Frame size 280 2 6217 C3 6217 C3 4000 h 25g
14/16BG. Frame size 280 4 to 8 6317 C3 6317 C3 8000 h 30g
14/16BG.310-317 Frame size 315 2 6316 C3 6316 C3 3000 h 30g
14/16BG.318-319 Frame size 315 2 6316 C3 6316 C3 2000 h 30g
14/16BG.310-317 Frame size 315 4 6319 C3 6319 C3 6000 h 40g
14/16BG.318-319 Frame size 315 4 6319 C3 6319 C3 3000 h 40g
14/16BG.310-319 Frame size 315 6..8 6319 C3 6319 C3 6000 h 40g
Horizontally mounted motors and coolant temperature up to 40°C, the Electric Motors Marine and Industrial
grease lifetime should be: Type of grease for standard machines: (Fa.ESSO / UNIREX N3), grease
Approx. 40,000 operation hours for speeds of 1500 rpm lifetime and lubrication intervals are valid for this type of grease only.
Approx. 20,000 operation hours for speeds of 3000 rpm Compensatory greases must conform to DIN 51825- KL3N at least. In
Irrespective of the number of operation hours, the grease should be this case the lubrication intervals at KT > 25 °C are to reduced.
renewed every 3 years because of ageing. Special greases are introduced on the lubricating data plate. If the
In the case of motors operating under special conditions, such as coolant temperature is increased by 10K, the grease life and
vertical motor position, frequent operation at maximum speed nmax’ regreasing interval are halved. Only relubricate bearings when the
heavy vibration, sudden load changes and frequent reversing motor has a speed of at least n > 300 rpm.
operation, the bearing should be changed at considerably more
frequent intervals than at the operating hour stated above.
30
Electric Motors Chapter 1
Degree of Protection
All motors are designed to IP55 degree of protection. They can be installed in dusty or humid environments. The motors are suitable for
operating in tropical climates. Guide value <60%, relative humidity at KT40°C.
Other requirements are available on request.
Most motors can be supplied in IP56 and IP65 degree of protection on request.
0 No special protection
4 Protected against solid objects over 1mm (tools, wire, and small wires)
0 No protection
4 Protection against water sprayed from all directions ° limited ingress permitted
5 Protected against low pressure jets of water from all directions ° limited ingress
6 Protected agains low pressure jets of water, e.g. for use on ship decks - limited ingress permitted
31
Electric Motors Chapter 1
Insulation System
For details of order codes for use in temperature class F, see "DURIGNIT Winding and insulation design with regard to temperature class and air
IR 2000 insulation system” under “windings and insulation". humidity
The following applies to all motors: The motors can withstand 1.5 times All motors are designed for temperature class F. At rated output with
the rated current at rated voltage and frequency for two minutes (DIN line- fed operation, the motors can be used in temperature class B.
EN 60034).
Temperature class F, used in accordance with F,
Ambient temperature:
All motors can be used in standard version at ambient temperatures with service factor (SF)
between – 20 and +40 °C. For all 7AA/7BA and 14BG motors for line- fed operation in frame sizes
Motors can be used in temperature class F 63 to 315 for rated output given in the selection table and rated output
given in the selection table and rated voltage, a service factor of 1.1
can be specified.
• at 40° C with service factor 1.1, i.e. the motor can be continuously
overloaded with 10 % of the rated output (for motors of 16BG and 9AA
series, with the exception of 9AA with increased output, with service Temperature class F, used in accordance with F,
factor 1.15, i.e. 15 % of the rated output).
for increased output
For motors supplied from stock for use in accordance with temperature
• above 40° C at rated output class F, the rated output according to the selection and ordering data
can be increased by 10 %.
When motors are used in temperature class B for higher ambient
temperatures and site altitudes derating occurs in accordance with
the table “ Reduction factor k HT for different site altitudes and/ or
Temperature class H for rated output and
ambient temperatures”. maximum ambient temperature (AT) 60 °C
For motors of series 7AA/7BA and 14BG use in accordance with
temperature class H is permitted at rated output and at a maximum
For other temperatures special measures are necessary. When brakes
ambient temperature of a 60 °C. The specified grease life applies at an
are to be mounted on motors intended for operation at temperatures
ambient temperature of 40 °C. For a 10 K increase in ambient
below freezing , please contact your local Lönne office.
temperature, the grease life of lubrication interval is halved.
Please contact your local Lönne office.
Winding and insulation
Temperature class F, used in accordance with B,
DURIGNIT IR 2000 insulation system ambient temperature 45 °C, approx. 4% derating
For motors of series 7AA/7BA and 14BG a version can be ordered that
The DURIGNIT IR 2000 insulation system comprises high- grade is designed to temperature class F, for use in accordance with
enameled wires and insulating sheet materials combined with solvent- temperature class B at a maximum ambient temperature of 45 ºC at
free impregnating resin. 4% derating.
32
Electric Motors Chapter 1
Temperature class F, used in accordance with B, Increased air temperature/ humidity with more
ambient temperature 50 °C, approx. 8% derating than 60 g up to 100 g water per m3 of air
For motors of series 7AA/7BA and 14BG a version can be ordered that For motors of series 7AA/7BA and 14BG a version can be ordered for
is designed to temperature class F, for use in accordance with increased air humidity of between 60 and 100 g water per m3 of air
temperature class B at a maximum ambient temperature of 50 ºC at depending on the temperatures as listed in table below. In this case,
8% derating. the external bolts can be supplied in rust- proof material. This option
not include any condensation protection, so an anti- condensation
heater (order code K45/ K46) must be ordered separately if required.
Temperature class F, used in accordance with B, Please contact your local Lönne office.
ambient temperature 55 °C, approx. 13% derating
For motors of series 7AA/7BA and 14BG a version can be ordered that
is designed to temperature class F, for use in accordance with
Increased air temperature/ humidity with 30 to 60
temperature class B at a maximum ambient temperature of 55 ºC at g water per m3 of air
13% derating. For motors of series 7AA/7BA and 14BG a version can be ordered for
increased air humidity of between 30 and 60 g water per m3 of air
depending on the temperatures as listed in table below. In this case,
Temperature class F, used in accordance with B, the external bolts can be supplied in rust- proof material. This option
ambient temperature 60 °C, approx. 18% derating not include any condensation protection, so an anti- condensation
For motors of series 7AA/7BA and 14BG a version can be ordered that heater ( order code K45/ K46) must be ordered separately if
is designed to temperature class F, for use in accordance with required.Please contact your local Lönne office.
temperature class B at a maximum ambient temperature of 60 ºC at
18% derating.Please contact your local Lönne office.
Relativehumidity Temp
30° C 40° C 50° C 60° C 70° C 80° C 90° C
20° C
10% 2 3 5 8 13 20 29 42
15% 3 5 8 12 19 30 44 63
20% 3 6 10 17 26 39 58 84
25% 4 8 13 21 32 49 73 105
30% 5 9 15 25 39 59 87 126
35% 6 11 18 29 45 69 102 146
40% 7 12 20 33 52 79 116 167
45% 8 14 23 37 58 89 131 188
50% 9 15 26 41 65 98 145 209
55% 10 17 28 43 71 108 160 230
60% 10 19 31 50 78 118 174 251
65% 11 20 33 54 84 128 189 272
70% 12 21 36 58 91 138 203 293
75% 13 23 38 62 97 148 218 314
80% 14 24 41 66 104 157 233 335
85% 15 26 43 70 110 167 247 356
90% 16 27 46 74 117 177 262 377
95% 16 29 49 79 123 187 276 398
100% 17 30 51 83 130 197 291 419
The values in the table with a light blue background are covered by the standard version (up to 30 g water per m3 of air)
The values in the table with a light grey background are covered by order code C19 (30 to 60 g of water per m3 of air)
The values in the table with a medium blue background are covered by order code C26 (60 to 100 g of water per m3 of air)
Please contact your Lönne office regarding requirements exceeding 100 g water per m3 of air.
33
Electric Motors Chapter 1
For current- sensitive motor protection, the protective switch has to be set to the rated current given on the name plate.
This motor protection is inadequate for high number of operations, short- time operation, coolant breakdown or for
fluctuations in coolant temperature. In this case motors should be protected by direct temperature protection (extra
price):
Thermistor protection
The embedded temperature sensors are able to work only in conjunction with a tripping unit. When reaching the
limiting temperature, the thermistor changes its resistance almost Instantaneousely.
This action is utilized in conjunction with the tripping unit to monitor motor temperature. The relay incorporated in the
device has a change- over contact, in which the contacts can be used for the control system.
Advantages: the protection system is self- monitoring; low switching tolerance;quick reconnection of the drive.
In standard the connection of the temperature protection is with a terminal block inside the main terminal box.
On request the connection in a separate mounted terminal box is possible.
WARNING: Thermometer voltage max 1V / Thermistors voltage max 5V.
230V 115V
Motors whose windings area at risk of condensation due the climatic conditions, e, g, inactive motors in humid
atmospheres or motors that are subjected to widely fluctuating temperatures can be equipped with anti- condensation
heaters.
34
Electric Motors Chapter 1
Noise(mains- fed operation) A- weighted measuring- surface sound pressure level and sound power levet at rated power
Standard design
The noise levels are measured in ac-
cordance with DIN EN 21 680-1 in a dead room Type series Size Measuring- surface sound pressure level (LpfA)
with rated power. LpfA is specified in dB (A) as
Sound power level (LWA)
the A- weighted measuring- surface sound
pressure level. 2- pole 4- pole 6- pole 8- pole
LpfA LWA LpfA LWA LpfA LWA Lpfa LWA
This value is the spatial mean value of the test
hemisphere. This test is hemi- sphere is a dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
cuboid at a distance of 1 m from the machine
surface. In addition, the sound power level 7BA 63 49 60 42 53 39 50 - -
LWA is specified in dB (A). The values are 71 52 63 44 55 39 50 36 47
applicable at 50 Hz with a tolerance of + 3 dB.
They are approximately 4 dB (A) higher at 60 80 56 67 47 58 40 51 41 52
Hz. Please enquire about the noise levels for
90 60 72 48 60 43 55 41 53
polechanging motors, motors with an
increased power output or motors for 100 62 74 53 65 47 59 45 57
converter- fed operation.
112 63 75 53 65 52 64 49 61
132 68 80 62 74 63 75 53 65
160 70 82 66 78 66 78 63 75
14BG 180 69 82 65 78 59 72 67 80
200 73 86 66 79 59 72 57 70
225 73 86 66 79 60 73 61 74
250 75 88 67 80 61 74 55 68
280 74 87 70 83 61 74 58 71
315 79 92 70 83 65 78 64 77
16BG 180 67 80 60 73 56 69 66 79
200 71 84 62 75 59 72 66 79
225 71 84 60 73 59 72 58 71
250 71 84 65 78 60 73 57 70
280 73 86 67 80 58 71 58 71
315 76 89 68 81 61 74 64 77
14BG 180 71 84 65 78 59 72 67 80
increased 200 73 86 66 79 61 74 57 70
power 225 73 86 66 79 60 73 61 74
250 75 88 67 80 61 74 55 68
280 74 87 70 83 61 74 58 71
315 - - - - 65 78 64 77
35
Electric Motors Chapter 1
In accordance with L.V. directive 73/23/ EEC Tighten the eyebolts. They are designed for the weight of the motor
only therefore do not attach any additional loads. If necessary, use
suitable, adequately dimensioned transporting equipment (e.g. rope
1 General Information guides). Remove existing shipping braces before commissioning; and
reuse for subsequent transport. If motors are stored, a dry, dust- free
and low vibration (Vrms <0.2 mm/ s) environment is important (to avoid
Electric motors have dangerous voltage carrying and rotating bearing standstill damage). On longterm storage, the regrease interval
components as well as surfaces that may become hot. All work of the bearings is reduced. Before commissioning, measure the
involved in the transport, connection, commissioning and regular impedance of the insulation. It values <1kW per volt of rated voltage
maintenance must be carried out by qualified, responsible specialists are measured; the windings must he dried out. When motors with roller
(note VDE 0105; IEC 364). improper behaviour may result in serious bearings for increased cantilever force are operated the, value of
injury and damage to property. The applicable national, local and cantilever force must be minimal 30% of permissible cantilever force
works regulations and requirements must be complied with. (see catalogue). Operating with smaller cent lever force is the cause
of bearing faults.
2 Intended use
These motors are intended for commercial installations. They comply 4 Installation
with the harmonized standards of the EN60034 (VDE 0530) series.
Utilization in areas subject to explosion hazard is not permitted, unless
expressly Intended for this purpose (see additional notes). In certain Ensure an even underlying surface, good foot or flange fixing and
special cases, for example. On use in noncommercial installations, it precise alignment for direct coupling. It is important to ensure that the
requirements are more strict (e.g. protection against contact with mounting conditions do not cause resonance with the rotational
children’s fingers), is it the responsibility of the customer to ensure frequency and the doubled supply frequency. Turn the rotor by hand
compliance on installing the equipment. The motors are rated for and listen for any unusual grinding noises. Check the direction of
ambient temperatures of -20oC to +40oC and site altitudes <1000m rotation in the decoupled state (note section 5).
above sea level. Any contradictory information. On the rating plate
must be observed. The conditions on site must correspond to all rating Only mount or remove drive components (belt pulley, coupling, etc.)
plate specifications. Low voltage motors are components for using suitable tools (heat up), and cover to shield against contact.
installation in machinery in terms of the Machine directive 89/392/ EEC, Avoid unpermissible belt tensions (see catalogue and technical data).
Commissioning must not take place until it has been proved that the The balancing type is specified on the shaft end face or rating plate (H
end product conforms with this guideline (please note EN 60204-1). =half- and F= full- key balancing). On mounting the drive, note the
balancing type! In the case of half key balancing, the protruding,
visible part of the half featherkey must be removed. A canopy is
3 Transport and storage recommended for designs with the shaft end pointing downwards, and
with the shaft end pointing upwards a cover must be provided by the
Any damage detected after dispatch should be reported immediately customer to prevent foreign bodies from falling into the fan.
to the transport company and commissioning must be postponed.
36
Electric Motors Chapter 1
Do not obstruct ventilation! Discharged air, also from neighbouring circuits (e.g. Anti- condensation heaters).Check that the equipment is
equipment, must not be sucked In again immediately. Checking of potential- free! If the tolerance limits are exceeded that are specified
bearing grease must he carry out when motors are longer than 12 in EN 60034, part 1 / IEC 34-1 (voltage ± 5%, frequency ± 2%, shape of
months storage. When storage conditions are the cause of grease curve, symmetry) the heating effect is increased and the
depreciation (presence of condensate, consistency change) the electromagnetic compatibility is affected. Please note the
grease must be exhanged. Grease exhange must be carry out no later specifications on the rating plate and the connection diagram in the
than in three year interval. terminal box. Connections must be made in such a way as to ensure
that a permanently safe electrical connection is maintained (no
protruding wire ends) use the corresponding cable end pieces. Create
5 Electrical connection a safe earth continuity connectien.
Work is only permitted to be carried out by qualified specialists on the
stationary motor, while disconnected and prevented from being
switched on again. This also applies for the auxiliary power
Tightning tourque (Nm) 0,8...1,2 1,8...2,5 2,7...4 5,5...8 9...13 14...20 27...40
Clearances in air between bare live parts themselves and between dust and water. Secure the featherkey on test operation without drive
bare live parts and earth must be > 5,5 mm {U rated < 690 V) If must be components. For motors with brakes, check that the brakes are
ensured that the terminal box does not contain foreign bodies, dirt or operating perfectly before commissioning.
humidity. Seal any unused cable entry openings against
2 2 2 2 2
25 mm 10 mm 25 mm 10 mm 25 mm
6 Operation
Vibration levels of Vrms<3,5mm/ s{PN £15 kW) or V rms < 4,5mm/ s (P N >15 For motors without regreasing facilities, bearing or grease replacement
kW} are quite acceptable in the coupled state. If deviations from must be carried out in accordance with the manufacturer’s
normal operation occur - e.g. increased temperatures, noises, instructions, or after 3 years, whichever is sooner. Bearings with
vibration - the motor should be switched off in the event of doubt. regreasing facilities must be regreased when the motor is running.
Determine the causes and contact the manufacturer if necessary. Do Please note the greasing plate!
not disconnect protective equipment, even under test operation.
Under dirty operating conditions, clean the air channels regularly. In case the motors with separate ventilation, the separately- driven fan
Open any closed condensate water holes from time to time! must be switched on throughout motor operation.
37
Electric Motors Chapter 1
Inverter control of Lönne electric motor allows an optimal reliable operation and automatic energy
saving. Soft start and stop control reduces mechanical stress on the machine.
Lönne three- phase asynchronous electric motor is designed to be supplied directly from our warehouses as standard products or as tailor
supplied by a frequency inverter. made systems.Yaskawa’s inverters are supplied in 1- phase within
The rotation speed of an asynchronous motor depends on the supply power range 0,1 to 2,2 kW and 3- phase in respectively 0,25 to 110 kW
voltage frequency. (200-230VAC) and 0,4 to 630 kW (380-480VAC).
This motor can be driven up to the rated frequency with supply voltage
proportional to the frequency. At higher frequencies the motor can be Lönne is also a recognized manufacturer of large drive systems, and
supplied at constant voltage. Lönne electric motor offers a wide range our engineered solutions are supplied for power range up to 5600 kW.
of overload capacity and a high thermal reserve. All engineering is done in- house and our systems are based on water
cooled inverters from Converteam. Inverters are supplied in modular
The insulating materials are class F. units from 800 to 5600 kW.
Lönne is a significant supplier of frequency inverters for industrial For more information, please call us to ask for catalogues, advices or
applications, propulsion and seismic compressor systems in an an appointment.
international maritime market. As being a certified distributor for
Yaskawa, these inverters are kept in stock and can be
38
Electric Motors Chapter 1
Flameproof Motors
Specifications
Cast - Iron
To norms IEC 600079-0, 60079-1, 60079 – 7 A21- tD
Ex- d, Ex- de Max surface temperature [°C] T150, T135, T100, T65
frame Size from 63 – 315 Protection IP55, IP56
ATEX category 1M2, 2G, 2GD To norms IEC 60034-1, 5, 6, 7, 8, 9, 12, 14, 60072
Group I (mine), IIB, IIC Output from 0,12 to 200 KW
Temperature class T3, T4, T5, T6 Three- phase 1 or 2 speed
To norms IEC, 61241-0, 61241-1
39
Electric Motors Chapter 1
40
Electric Motors Chapter 1
Appendix
You may return any cast- off Lönne products to a Lönne Warehouse. Lönne is obliged to fulfil the authorities’
requirements regarding an environmentally sound handling of EE- waste in accordance with the EE regulations.
Price Policy
Prices are excl. VAT and packaging.
The exchange rate used for invoicing will be adjusted if it has changed by more than 2,00% in relation to the
NOK/ EUR exchange rate 8,10.
SEK/ EUR exchange rate 9,39
DKK/ EUR exchange rate 7,46
General
All product names occurring or referred to in this catalogue are or may be registered trademarks belonging to their
respective producers or trademark owners.
General Export and Import Regulations regarding Lönne Product Range of Drives and Controls will be subject to the
Export Import Regulations actual in the area of delivery.
We hereby reserve the right to change the content of data in this catalogue at any time without notice. Furthermore,
our company shall not be held responsible for neither possible discrepancies in catalogue content nor any damage
caused by wrong use of products or information.
Lönne Scandinavia AS reserves the prohibition to publish pages or whole parts of this catalogue without athorization.
41
Solutions | Products | Services
Head Office
Tel: +47 55 39 10 00 Tel: +46 (0) 42 38 03 00 Tel: +45 76 40 87 00 Tel: +358 (0) 9 342 4300
Fax: +47 55 39 11 00 Fax: +46 (0) 42 38 03 09 Fax: +45 76 40 87 01 Fax: +358 (0) 9 3424 3099
Local mail: info.norway@lonne.com Local mail: info.sweden@lonne.com Local mail: info.denmark@lonne.com Local mail: info.finland@lonne.com
24-h. service: +47 918 33 073 24-h. service: +46 (0) 70 885 5431 24-h. service: +45 (0) 24 45 74 03
info.international@lonne.com
www.lonne.com
Revision 0 09 2010 HH