Technical Information

Proportional Valve Group


PVG 16

powersolutions.danfoss.com
Technical Information
PVG 16 Proportional Valve Group

Revision history Table of revisions

Date Changed Rev

January 2018 Major update. 0601

July 2017 Major update. 0501

February 2017 Major update. 0401

March 2016 Minor update in PVHC technical characteristics 0303

March 2016 Updated to Engineering Tomorrow design. 0302

February 2016 Drawing was updated in topic: How to select the correct spool 0301

September 2015 PVG 16 Step II 0200

Feb. 2013-Mar. 2015 Major layout revision, drawings change BA-BF

October 2012 New Edition AA

2 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

Contents

General Information
General Description.........................................................................................................................................................................5
PVG 16 Features................................................................................................................................................................................ 5
PVG 16 Modules Overview............................................................................................................................................................6
PVP Inlet Modules
Open Center PVP.............................................................................................................................................................................. 8
Open Center PVP with PPRV...................................................................................................................................................... 10
Open center PVP with PPRV and adjustment spool..........................................................................................................13
Closed Center PVP......................................................................................................................................................................... 16
Closed Center PVP with PPRV....................................................................................................................................................18
PVPX, Electrical LS Pressure Unloading Valve......................................................................................................................20
PVB Basic Modules
Compensated PVB......................................................................................................................................................................... 24
Compensated PVB with PVLP/PVLA........................................................................................................................................27
Compensated PVB with LS A/B................................................................................................................................................. 31
Uncompensated PVB....................................................................................................................................................................34
Uncompensated PVB with PVLP...............................................................................................................................................36
PVLP, Shock/Anti-Cavitation and PVLA, Suction Valves...................................................................................................39
PVBS Main Spools
Electric and/or Mechanical Actuation, Symmetrical PVBS Spools................................................................................43
Electric and/or Mechanical Actuation, Asymmetrical PVBS Spools............................................................................. 46
Hydraulic and/or Mechanical Actuation Symmetrical PVBS Spools............................................................................49
Hydraulic and/or Mechanical Actuation, Asymmetrical PVBS Spools........................................................................ 51
PVG 16 Actuation
PVM Manual Actuation................................................................................................................................................................ 54
PVMD Cover................................................................................................................................................................................56
PVH Hydraulic Actuation.............................................................................................................................................................57
PVHC Electro-Hydraulic Actuation...........................................................................................................................................59
PVE Electrical Actuation...............................................................................................................................................................61
PVEO – ON/OFF Voltage Control Actuator........................................................................................................................... 63
PVEO Technical Data............................................................................................................................................................... 65
PVEA – Proportional Spool Control Actuator.......................................................................................................................66
PVEA Technical Data................................................................................................................................................................67
PVG 16 Connector Variants........................................................................................................................................................ 69
Fault Monitoring and Fault Reaction
Generic Fault Reaction................................................................................................................................................................. 70
Fault Reaction Overview..............................................................................................................................................................71
PVS End Plates
PVS/PVSI ........................................................................................................................................................................................... 73
PVS/PVSI with LX-connection....................................................................................................................................................75
PVSI with P-, T-, LX- and M-connection.................................................................................................................................. 77
PVST with T-connection...............................................................................................................................................................79
PVAS Stay Bolts
PVAS Part Numbers....................................................................................................................................................................... 82
PVG 16 modules total length and weight.............................................................................................................................82
PVG 32/16 Combinations............................................................................................................................................................ 83
PVG 256/128/32/16 Combinations..........................................................................................................................................84
PVG 16 Combinations Valve Stack Dimensions
PVG 16 Dimensions....................................................................................................................................................................... 86
PVG 32/16 Dimensions.................................................................................................................................................................87
PVG 100/16 Dimensions.............................................................................................................................................................. 89
PVG 120/16 Dimensions.............................................................................................................................................................. 91
PVG 128/16 Dimensions.............................................................................................................................................................. 93
PVG 256/16 Dimensions.............................................................................................................................................................. 95

© Danfoss | January 2018 BC00000211en-US0601 | 3


Technical Information
PVG 16 Proportional Valve Group

Contents

PVG 16 Applications Schematics


PVG 16 Schematic with Basic End Plate................................................................................................................................. 97
PVG 16 with P- and T-connection end plate........................................................................................................................ 98

4 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

General Information

General Description
PVG is a hydraulic, load-sensing proportional valve, designed for optimal machine performance and
maximum design flexibility. The PVG valve design is based on a modular concept that enables machine
designers to specify a valve solution suitable for multiple market segments across multiple applications.
The PVG 16 is a member of the PVG product platform.
PVG 16 controls work port flow up to 65 l/min and up to 420 bar work port pressure.
The load independent proportional control valve and high performance actuator technology combined
with a low pressure drop design improves the machine performance and efficiency – increasing
productivity and reducing energy consumption.

PVG 16 Features
PVG load-sensing proportional valves features and benefits summarized in a few bullets.
• Inlet flow up to 140 l/min [37 US gal/min] 230 l/min [61 US gal/min] when used with mid-inlet
• Easy integration with PVG 32
• Possible combination with the rest of the PVG family: PVG 100, PVG 120 or PVG 128/256 when using
an interface module
• Up to 12 basic modules per PVG 16 valve group
• Load-independent flow control:
‒ Oil flow to an individual function is independent of the load pressure of this function
‒ Oil flow to one function is independent of the load pressure of other functions
• Reliable regulation characteristics across the entire flow range
• Load sense relief valves for A and B port enables reduced energy loss at target pressure
• Several options for connection threads and flange mount
• Compact design, easy installation and serviceability

© Danfoss | January 2018 BC00000211en-US0601 | 5


Technical Information
PVG 16 Proportional Valve Group

General Information

PVG 16 Modules Overview


PVG proportional valve group shown in the exploded view illustration for a quick modules navigation.
PVG 16 Modules Assembly Overview

PVP PVE

PVM PVBS PVB PVH/Covers

PVS PVHC

PVAS

PVG Modules Navigation:


PVP Inlet Modules on page 7
PVB Basic Modules on page 22
PVBS Main Spools on page 42
PVM Manual Actuation on page 54
PVE Electrical Actuation on page 61
PVH Hydraulic Actuation on page 57
PVHC Electro-Hydraulic Actuation on page 59
PVS End Plates on page 72
PVAS Stay Bolts on page 81

6 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

The PVG 16 PVP inlet modules, also referred to as pump side modules, act as an interface between the
PVG 16 proportional valve group and the hydraulic pump and tank reservoir.
PVP Inlet Module

The PVP inlet module variants are based on a generic platform with a selection of additional features,
enabling you to tailor the PVP to suit the demands of any hydraulic system.

Symbols
Fixed displacement pump Variable displacement pump

The generic PVP inlet module platform includes the following main variants:
• Open center PVP for fixed displacement pumps; Open Center PVP on page 8
• Open center PVP with PPRV for fixed displacement pumps, Open Center PVP with PPRV on page 10
• Open center PVP with PPRV and damped pressure adjustment spool for fixed displacement pumps;
Open center PVP with PPRV and adjustment spool on page 13
• Closed center PVP for variable displacement pumps; Closed Center PVP on page 16
• Closed center PVP with PPRV for fixed displacement pumps; Closed Center PVP with PPRV on page 18

PVP inlet module dimensions


112.5 [4.43]

95 [3.74] 23 [0.9]
110 [4.33] 48 [1.89]

Weight: 3.1 kg [6.9 lb]

© Danfoss | January 2018 BC00000211en-US0601 | 7


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Open Center PVP


The basic Open Center PVP inlet module is intended for use with fixed displacement pumps in
applications, where a valve group with mechanically controlled work sections is desired, or where the
pilot pressure to the valve group is supplied externally.
The Open Center PVP features:
• Integrated LS pressure relief valve
• Threaded ports for P/T/LS and M measuring gauge
• Optional LS unloading valve, PVPX

Open center PVP schematic


LS M

Integrated LS pressure relief valve characteristic (Theoretical)


P P
[psi] (bar)
300
4000

250

3000
200

150
2000

100

1000
50

0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]

8 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

PVP Neutral By-pass pressure drop characteristics

[psi] (bar)
20

240
16

12
160

80
4

0 0
0 20 40 60 80 100 120 140 (l/min)

0 4 8 12 16 20 24 28 32 36 [US gal/min]

Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Open Center PVP


Part number P-port T-port LS-port M-port Mounting PVPX*
157B5000 G1/2” G3/4” G1/4” G1/4” M8 –

157B5100 G3/4” G3/4” G1/4” G1/4” M8 –

157B5102 G3/4” G3/4” G1/4” G1/4” M8 Yes

157B5200 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF 5/16-18 UNC –

157B5300 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF 5/16-18 UNC –


* For more information see PVPX, Electrical LS Pressure Unloading Valve on page 20

© Danfoss | January 2018 BC00000211en-US0601 | 9


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Open Center PVP with PPRV


The Open Center PVP inlet with integrated pilot pressure reduction valve (PPRV) is intended for use with
fixed displacement pumps in applications, where a valve group with electro-hydraulically or hydraulically
controlled work sections is desired (PVE or PVH/PVHC).
The Open Center PVP features:
• Integrated LS pressure relief valve
• Threaded ports for P/T/LS and M measuring gauge
• Integrated pilot pressure reducing valve (PPRV) for PVE or PVH/PVHC
• Optional external pilot pressure port (Pp)
• Optional LS unloading valve, PVPX

Open center PVP with PPRV schematic


LS M

P Pp

Integrated LS pressure relief valve characteristic (Theoretical)


P P
[psi] (bar)
300
4000

250

3000
200

150
2000

100

1000
50

0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]

10 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

PVP Neutral By-pass pressure drop characteristics

[psi] (bar)
20

240
16

12
160

80
4

0 0
0 20 40 60 80 100 120 140 (l/min)

0 4 8 12 16 20 24 28 32 36 [US gal/min]

PVP pilot pressure characteristics

[psi] (bar)

260 20
18
220
16

180 14
12
140
10
100 8

60 6
4
20
2
0 0
0 10 20 30 40 50 (l/min)

0 2 4 6 8 10 12 [US gal/min]

Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Open Center PVP with PPRV


Part number Actuation P-port T-port LS-port M-port Pp-port Mounting PVPX*
157B5010 PVE G1/2” G3/4” G1/4” G1/4” – M8 –

157B5012 PVE G1/2” G3/4” G1/4” G1/4” – M8 Yes

© Danfoss | January 2018 BC00000211en-US0601 | 11


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Part numbers for Open Center PVP with PPRV (continued)


Part number Actuation P-port T-port LS-port M-port Pp-port Mounting PVPX*
157B5110 PVE G3/4” G3/4” G1/4” G1/4” – M8 –

157B5112 PVE G3/4” G3/4” G1/4” G1/4” – M8 Yes

157B5180 PVE G3/4” G3/4” G1/4” G1/4” G1/4” M8 –

157B5190 PVH/PVHC G3/4” G3/4” G1/4” G1/4” G1/4” M8 –

157B5210 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC –

157B5212 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC Yes

157B5310 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC –

157B5312 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC Yes

157B5380 PVE 1 1/16 UN 1 1/16 UN 1/2-20 UNF 1/2-20 UNF 9/16-18 UNF 5/16-18 UNC –

157B5390 PVH/PVHC 1-1/16 UN 1-1/16 UN 9/16-18 UNF 9/16-18 UNF 9/16-18 UNF 5/16-18 UNC –
* For more information please see PVPX, Electrical LS Pressure Unloading Valve on page 20

All modules can be manually activated with the PVM. For more information please see PVM Manual
Actuation on page 54.

12 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Open center PVP with PPRV and adjustment spool


The Open Center PVP inlet with integrated pilot pressure reduction valve (PPRV) is intended for use with
fixed displacement pumps in applications where a valve group with electro-hydraulic or hydraulically
controlled work sections is desired.
The Open Center PVP features:
• Integrated LS pressure relief valve
• Threaded ports for P/T/LS and M measuring gauge
• Integrated pilot pressure reducing valve (PPRV) for PVE or PVH/PVHC
• Optional external pilot pressure port (Pp)

Open center PVP with PPRV, adjustment spool schematic


LS M

Integrated LS pressure relief valve characteristic (Theoretical)


P P
[psi] (bar)
300
4000

250

3000
200

150
2000

100

1000
50

0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]

© Danfoss | January 2018 BC00000211en-US0601 | 13


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

PVP Neutral By-pass pressure drop characteristics

[psi] (bar)
20

240
16

12
160

80
4

0 0
0 20 40 60 80 100 120 140 (l/min)

0 4 8 12 16 20 24 28 32 36 [US gal/min]

PVP pilot pressure characteristics

[psi] (bar)

260 20
18
220
16

180 14
12
140
10
100 8

60 6
4
20
2
0 0
0 10 20 30 40 50 (l/min)

0 2 4 6 8 10 12 [US gal/min]

Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

14 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Part numbers OC PVP with PPRV, adjustment spool


Part number Actuation P-port T-port LS-port M-port Pp-port Mounting PVPX*
11008849 PVE G3/4” G3/4” G1/4” G1/4” G1/4” M8 -

11008851 PVH G3/4” G3/4” G1/4” G1/4” G1/4” M8 -


* For more information please see PVPX, Electrical LS Pressure Unloading Valve on page 20

All modules can be manually activated with the PVM. For more information please see PVM Manual
Actuation on page 54.

© Danfoss | January 2018 BC00000211en-US0601 | 15


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Closed Center PVP


The basic Closed Center PVP inlet is intended for use with variable displacement pumps in applications
where a valve group with mechanically controlled work sections is desired, or where the pilot pressure to
the valve group is supplied externally.
The Closed Center PVP features:
• Integrated LS pressure relief valve
• Threaded ports for P/T/LS and M measuring gauge
• Optional LS unloading valve, PVPX

Closed center PVP schematic


LS M

Integrated LS pressure relief valve characteristic (Theoretical)


P P
[psi] (bar)
300
4000

250

3000
200

150
2000

100

1000
50

0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]

Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]

16 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Technical Data (continued)


Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Closed Center PVP


Part number P-port T-port LS-port M-port Mounting PVPX*
157B5001 G1/2” G3/4” G1/4” G1/4” M8 -

157B5101 G3/4” G3/4” G1/4” G1/4” M8 -

157B5103 G3/4” G3/4” G1/4” G1/4” M8 Yes

157B5201 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF 5/16-18 UNC -

157B5301 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF 5/16-18 UNC -


* For more information please see PVPX, Electrical LS Pressure Unloading Valve on page 20

© Danfoss | January 2018 BC00000211en-US0601 | 17


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

Closed Center PVP with PPRV


The Closed Center PVP inlet with integrated pilot pressure reduction valve (PPRV) is intended for use with
variable displacement pumps in applications where a valve group with electro-hydraulic or hydraulically
controlled work sections is desired.
The Closed Center PVP features:
• Integrated LS pressure relief valve
• Threaded ports for P/T/LS and M measuring gauge
• Integrated pilot pressure reducing valve (PPRV) for PVE or PVH/PVHC
• Optional external pilot pressure port (Pp)
• Optional LS unloading valve, PVPX

Closed center PVP with PPRV schematic


LS M

P Pp

Integrated LS pressure relief valve characteristic (Theoretical)


P P
[psi] (bar)
300
4000

250

3000
200

150
2000

100

1000
50

0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]

18 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

PVP pilot pressure characteristics

[psi] (bar)

260 20
18
220
16

180 14
12
140
10
100 8

60 6
4
20
2
0 0
0 10 20 30 40 50 (l/min)

0 2 4 6 8 10 12 [US gal/min]

All modules can be manually activated with the PVM. For more information please see PVM Manual
Actuation on page 54.

Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Closed Center PVP with PPRV


Part number Actuation P-port T-port LS-port M-port Pp-port Mounting PVPX*
157B5011 PVE G1/2” G3/4” G1/4” G1/4” - M8 -

157B5013 PVE G1/2” G3/4” G1/4” G1/4” - M8 Yes

157B5111 PVE G3/4” G3/4” G1/4” G1/4” - M8 -

157B5113 PVE G3/4” G3/4” G1/4” G1/4” - M8 Yes

157B5181 PVE G3/4” G3/4” G1/4” G1/4” G1/4” M8 -

157B5191 PVH/PVHC G3/4” G3/4” G1/4” G1/4” G1/4” M8 -

157B5211 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC -

157B5213 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC Yes

157B5311 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC -

157B5313 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC Yes

157B5381 PVE 1-1/16 UN 1-1/16 UN 9/16-18 UNF 9/16-18 UNF 9/16-18 UNF 5/16-18 UNC -

157B5391 PVH/PVHC 1-1/16 UN 1-1/16 UN 9/16-18 UNF 9/16-18 UNF 9/16-18 UNF 5/16-18 UNC
* For more information please see PVPX, Electrical LS Pressure Unloading Valve on page 20

© Danfoss | January 2018 BC00000211en-US0601 | 19


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

PVPX, Electrical LS Pressure Unloading Valve


The PVPX, electrical LS pressure unloading valve is an accessory available for PVP inlet modules used for
PVG 16.
The PVPX consist of a solenoid valve and a magnetic coil package, allowing the operator to relieve the LS
pressure to tank electrically. Variants also feature a manual override functionality to activate the PVPX
manually. Relieving the LS pressure to tank results in a reduced system pressure.
• In an Open Center configuration PVP the reduced system pressure level is determined by the sum of
the tank pressure and the neutral by-pass pressure drop.
• In a Closed Center configuration PVP the reduced system pressure level is determined by the sum of
the tank pressure and the standby-pressure.

Configuration variants
Normally Open (NO) Normally Open with Manual Normally Closed (NC)
Override (NOMO)

PVPX with NOMO schematic


LS M

Technical Data
Max. pressure drop @ 0.1 l/min [2.6 US gal/min] 2 bar [30 psi]
Max. coil surface temperature 155°C [311°F]
Oil temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90°C [194°F]300 ms
Ambient recommended temperature range -30 to 60°C [-22 to 140°F]
Oil viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2300/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Oil cleanliness according to ISO 4406 23/19/16

20 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVP Inlet Modules

PVPX electrical data


Voltage supply 12 VDC ± 10% 24 VDC ± 10%
Resistance 7.2 Ω ± 7% 28.2 Ω ± 7%
Power consumption 20 W
Max. LS pressure relief response time

Part numbers for PVPX


Part number Configuration Manual Override Voltage Supply Connector Thread Size IP Rating
157B4236 NO - 12 VDC 1x2 DIN 3/4-16 UNF IP65

157B4238 NO - 24 VDC 1x2 DIN 3/4-16 UNF IP65

157B4246 NC - 12 VDC 1x2 DIN 3/4-16 UNF IP65

157B4248 NC - 24 VDC 1x2 DIN 3/4-16 UNF IP65

157B4256 NOMO PUSH 12 VDC 1x2 DIN 3/4-16 UNF IP65

157B4257 NOMO PUSH & TURN 24 VDC 1x2 DIN 3/4-16 UNF IP65

157B4258 NOMO PUSH 12 VDC 1x2 DIN 3/4-16 UNF IP65

157B4259 NOMO PUSH & TURN 24 VDC 1x2 DIN 3/4-16 UNF IP65

157B4260 NOMO PUSH 26 VDC 1x2 DIN 3/4-16 UNF IP65

157B4976 NC - 26 VDC 1x2 DIN 3/4-16 UNF IP65

157B4981 NO - 12 VDC 1x2 AMP 3/4-16 UNF IP66

157B4982 NO - 24 VDC 1x2 AMP 3/4-16 UNF IP66

157B4983 NC - 12 VDC 1x2 AMP 3/4-16 UNF IP66

157B4984 NC - 24 VDC 1x2 AMP 3/4-16 UNF IP66

157B4985 NOMO PUSH 12 VDC 1x2 AMP 3/4-16 UNF IP66

157B4986 NOMO PUSH 24 VDC 1x2 AMP 3/4-16 UNF IP66

11180766 NO - 12 VDC 1x2 DEU 3/4-16 UNF IP65

11180767 NO - 24 VDC 1x2 DEU 3/4-16 UNF IP65

11180768 NC - 12 VDC 1x2 DEU 3/4-16 UNF IP65

11180769 NC - 24 VDC 1x2 DEU 3/4-16 UNF IP65

© Danfoss | January 2018 BC00000211en-US0601 | 21


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

The PVB basic modules, also referred to as work sections, is the interface between the proportional valve
group and the work function such as a cylinder or a motor.
PVB basic module

The PVB basic module variants are based on a generic platform with a selection of additional features,
enabling you to tailor the PVB to suit the demands of any hydraulic system. The generic PVB basic
module platform includes the following main variants:

Symbols
Uncompensated PVB Compensated PVB

• Compensated basic module; Compensated PVB on page 24


• Compensated basic module with facilities for shock and anti-cavitation valves (PVLP/PVLA);
Compensated PVB with PVLP/PVLA on page 27
• Compensated basic module with one common adjustable LS valve for port A and port B;
Compensated PVB with LS A/B on page 31
• Uncompensated basic module with optional integrated load drop check valve; Uncompensated PVB
on page 34
• Uncompensated basic module with facilities for shock valves (PVLP) and optional integrated load
drop check valve; Uncompensated PVB with PVLP on page 36

22 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVB dimensions

114 [4.49]
109 [4.29]

110 [4.33] 20 [0.79]


40 [1.57]

Weight: 2,6 kg [5,7 lb]

© Danfoss | January 2018 BC00000211en-US0601 | 23


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Compensated PVB
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The Compensated PVB features:
• Integrated LS shuttle network
• Integrated compensator

Compensated PVB schematic

1 0 2
A

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218

24 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVB pressure compensated fluid flow characteristics


(l/min) [US gal/min]

70
18
65 17

60 16
AA = 5/min D
15
55 A = 10 l/min
14
B = 15 l/min
50 13 C = 25 l/min
45 12 D = 40 l/min
11
40
10
35 C
9
30 8
7
25
6
B
20 5
15 4
3
10
2 A
5 AA
1
P
0 25 50 75 100 125 150 175 200 225 250 275 300 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 [psi]

PVB pressure compensated P-line and T-line characteristics

P P
[psi] (bar)
Port A/B
5
70
4,5
60
4

50 3,5
T-line
3
40
2,5
P-line
30 2

20 1,5

1
10
0,5

0 0 Q
0 25 50 75 100 125 150 (l/min)
Q
0 5 10 15 20 25 30 35 40 [US gal/min]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]

© Danfoss | January 2018 BC00000211en-US0601 | 25


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Technical data (continued)


Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Compensated PVB


Part number A/B-port
11130976 3/8” BSP

11130977 3/4” – 16 UNF

26 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Compensated PVB with PVLP/PVLA


The compensated PVB featuring an optional PVLP/PVLA shock and anti-cavitation valves on each work
port for pressure peak protection and anti-cavitation prevention, is intended for controlling a work
function where the function behavior in terms of flow and pressures requires independence on the load
pressure of other functions used simultaneously.
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
Optional shock and featuring an optional PVLP/PVLA shock and anti-cavitation valves on each work port
for pressure peak protection and anti-cavitation prevention.
The Compensated PVB with PVLP/PVLA features:
• Integrated LS shuttle network
• Integrated compensator
• Optional shock and anti-cavitation valve facility (PVLP/PVLA)

Compensated PVB with PVLP/PVLA schematic

1 0 2
A

© Danfoss | January 2018 BC00000211en-US0601 | 27


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218

PVLP shock valve characteristics


P
[psi] (bar)
3000
400

2500 350

300
2000
250

1500
200

150
1000

100

500
50

0 0 Q
0 20 40 60 80 100 120 140 (l/min)
Q
0 5 10 15 20 25 30 35 40 45 [US gal/min]

28 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVLP/PVLA suction valve characteristics


P P
[psi] [bar]

400 28

26
360
24
320 22
20
280 PVLP
18
240
16

200 14

12 PVLA
160
10
120 8

80 6
4
40
2

0 0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 [US gal/min]

PVB pressure compensated fluid flow characteristics


(l/min) [US gal/min]

70
18
65 17

60 16
AA = 5/min D
15
55 A = 10 l/min
14
B = 15 l/min
50 13 C = 25 l/min
45 12 D = 40 l/min
11
40
10
35 C
9
30 8
7
25
6
B
20 5
15 4
3
10
2 A
5 AA
1
P
0 25 50 75 100 125 150 175 200 225 250 275 300 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 [psi]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]

© Danfoss | January 2018 BC00000211en-US0601 | 29


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Technical data (continued)


Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Compensated PVB with PVLP/PVLA


Part number A/B-port PVLP/PVLA
11130978 3/8” BSP 1

11130979 3/4” – 16 UNF 1

30 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Compensated PVB with LS A/B


The compensated PVB with the integrated LS A/B relief valves is intended for controlling a work function
where the function behavior in terms of flow and pressures requires independence on the load pressure
of other functions used simultaneously.
The integrated LS A/B relief valves are used to limit the maximum work port pressure on the A and B
ports individually.
The Compensated PVB with LS A/B features:
• Integrated LS shuttle network
• Integrated compensator
• Integrated adjustable LS A/B pressure relief valves

Compensated PVB with LS A/B schematic

1 0 2
A

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218

© Danfoss | January 2018 BC00000211en-US0601 | 31


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVB pressure compensated for LS A/B characteristics

Q
(l/min) [US gal/min]

70
18
65 17

60 16
15
55
14
50 13
45 12
11
40
10
35 9
30 8
7
25
6
20 5
15 4
3
10
2
5
1
0 P
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 [psi]

PVB pressure compensated fluid flow characteristics


(l/min) [US gal/min]

70
18
65 17

60 16
AA = 5/min D
15
55 A = 10 l/min
14
B = 15 l/min
50 13 C = 25 l/min
45 12 D = 40 l/min
11
40
10
35 C
9
30 8
7
25
6
B
20 5
15 4
3
10
2 A
5 AA
1
P
0 25 50 75 100 125 150 175 200 225 250 275 300 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 [psi]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]

32 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Technical data (continued)


Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Compensated PVB with LS A/B


Part number A/B-port
11130982 3/8” BSP

11130983 3/4” – 16 UNF

© Danfoss | January 2018 BC00000211en-US0601 | 33


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Uncompensated PVB
The uncompensated PVB is intended for controlling a work function where the function behavior in
terms of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The Uncompensated PVB features:
• Integrated LS shuttle network
• Optional load drop check valve

Uncompensated PVB schematic

1 0 2
A

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218

34 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVB pressure compensated P-line and T-line characteristics

P P
[psi] (bar)
Port A/B
5
70
4,5
60
4

50 3,5
T-line
3
40
2,5
P-line
30 2

20 1,5

1
10
0,5

0 0 Q
0 25 50 75 100 125 150 (l/min)
Q
0 5 10 15 20 25 30 35 40 [US gal/min]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Uncompensated PVB


Part number A/B-port Check valve
11106801 3/8” BSP Yes

11101421 3/8” BSP —

11106797 3/4” – 16 UNF Yes

11101423 3/4” – 16 UNF —

© Danfoss | January 2018 BC00000211en-US0601 | 35


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Uncompensated PVB with PVLP


The uncompensated PVB featuring an optional PVLP shock valve on each work port for pressure peak
protection and anti-cavitation prevention, is intended for controlling a work function where the function
behavior in terms of flow and pressures requires independence on the load pressure of other functions
used simultaneously.
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The Uncompensated PVB with PVLP features:
• Integrated LS shuttle network
• Optional shock valve facility (PVLP)
• Optional load drop check valve

Uncompensated PVB with PVLP schematic

1 0 2
A

36 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218

PVLP shock valve characteristics


P
[psi] (bar)
3000
400

2500 350

300
2000
250

1500
200

150
1000

100

500
50

0 0 Q
0 20 40 60 80 100 120 140 (l/min)
Q
0 5 10 15 20 25 30 35 40 45 [US gal/min]

© Danfoss | January 2018 BC00000211en-US0601 | 37


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVB pressure compensated P-line and T-line characteristics

P P
[psi] (bar)
Port A/B
5
70
4,5
60
4

50 3,5
T-line
3
40
2,5
P-line
30 2

20 1,5

1
10
0,5

0 0 Q
0 25 50 75 100 125 150 (l/min)
Q
0 5 10 15 20 25 30 35 40 [US gal/min]

Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part numbers for Uncompensated PVB with PVLP


Part number A/B-port PVLP Check valve
11101424 3/8” BSP 1 Yes

11106754 3/8” BSP 1 —

11101425 3/4” – 16 UNF 1 Yes

11106755 3/4” – 16 UNF 1 —

38 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVLP, Shock/Anti-Cavitation and PVLA, Suction Valves


The PVLP Shock/Anti-Cavitation valve is an accessory available for PVB basic and PVP inlet modules. The
PVLA valve is an accessory available for PVB basic modules only.

PVLP shock/anti-cavitation valve


The PVLP shock and anti-cavitation valve will relieve a pressure peak to the internal tank galleries and will
furthermore suck oil from the tank to the work port to prevent cavitation. Pressure settings range 32–400
bar [460–5801 psi].

The pressure setting of the PVLP must always be 20 bar [290 psi] higher than LS A/B setting in the same
module.
PVLP schematic

Port pressure

P109174

PVLP shock valve characteristics


P
[psi] (bar)
3000
400

2500 350

300
2000
250

1500
200

150
1000

100

500
50

0 0 Q
0 20 40 60 80 100 120 140 (l/min)
Q
0 5 10 15 20 25 30 35 40 45 [US gal/min]

PVLA suction valve


The PVLA will suck fluid from the tank to the work port to prevent cavitation by the 0.5 bar spring. The
plug will ensure that when using a single acting spool, all flow returning through the work port is led to
tank.
PVLA schematic

Port pressure

P109175

© Danfoss | January 2018 BC00000211en-US0601 | 39


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

PVLP/PVLA suction valve characteristics


P P
[psi] [bar]

400 28

26
360
24
320 22
20
280 PVLP
18
240
16

200 14

12 PVLA
160
10
120 8

80 6
4
40
2

0 0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 [US gal/min]

Fluid technical specification


Fluid temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended range -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

40 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVB Basic Modules

Part numbers for PVLP and PVLA valves


Description Pressure setting in bar Part number
PVLP shock valve 32 157B2032
50 157B2050
63 157B2063
80 157B2080
100 157B2100
125 157B2125
140 157B2140
150 157B2150
160 157B2160
175 157B2175
190 157B2190
210 157B2210
230 157B2230
240 157B2240
250 157B2250
265 157B2265
280 157B2280
300 157B2300
320 157B2320
350 157B2350
380 157B2380
PVLA suction valve — 157B2001
PLUG — 157B2002

© Danfoss | January 2018 BC00000211en-US0601 | 41


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

The main spools (PVBS) determines the flow out of the work section or the pressure build up.
PVBS main spool

The PVBS main spool variants are based on a generic platform with a wide selection of additional
features, enabling you to tailor the PVBS to suit the demands of any hydraulic system and any function.
The PVBS main spool can be activated in three different ways:
• Mechanically by a PVM lever
• Electrically by a PVE/PVHC actuator
• Hydraulically by a PVH actuator

The generic platform includes the following main variants:


• Electric and/or Mechanical Actuation Symmetrical PVBS Spools
‒ Standard FC spools throttled open neutral position
‒ Standard FC spools closed neutral position
• Electric and/or Mechanical Actuation Asymmetrical PVBS Spools
‒ Standard FC spools throttled open neutral position
‒ Standard FC spools closed neutral position
• Hydraulic and/or Mechanical Actuation Symmetrical PVBS Spools
‒ Standard FC spools throttled open neutral position
‒ Standard FC spools closed neutral position
• Hydraulic and/or Mechanical Actuation Asymmetrical PVBS Spools
‒ Standard FC spools throttled open neutral position
‒ Standard FC spools closed neutral position
PVBS main spool dimensions

110 [4.33] 46 [1.81] 14.8 [0.59]

Weight: 0.16 kg [ 0.35 lb]


For more information please see:

Electric and/or Mechanical Actuation, Symmetrical PVBS Spools on page 43


Electric and/or Mechanical Actuation, Asymmetrical PVBS Spools on page 46
Hydraulic and/or Mechanical Actuation Symmetrical PVBS Spools on page 49
Hydraulic and/or Mechanical Actuation, Asymmetrical PVBS Spools on page 51

42 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Electric and/or Mechanical Actuation, Symmetrical PVBS Spools


PVBS Electric and/or Mechanical Actuation symmetrical spools with standard FC spools featuring either
throttled open or closed neutral position

Standard FC Spools Throttled Open Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• Spools with flow range from 5 - 65 l/min

Part numbers for symmetrical open neutral spools


Part number P → A/B Flow Control Dead Band
l/min [US gal/min] mm [in]

11105537 5 [1.32] FC AB 1.2 [ 0.047]

11105538 10 [2.64] FC AB 1.2 [ 0.047]

11105539 25 [6.60] FC AB 1.2 [ 0.047]

11105540 40 [10.57] FC AB 1.2 [ 0.047]

11105541 65 [17.17] FC AB 1.2 [ 0.047]

Standard FC Spools Closed Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• Spools with flow range from 5 - 65 l/min

Part numbers for symmetrical closed neutral position spools


Part number P → A/B Flow Control Dead Band
l/min [US gal/min] mm [in]

11105532 5 [1.32] FC AB 1.2 [ 0.047]

11105533 10 [2.64] FC AB 1.2 [ 0.047]

11105534 25 [6.60] FC AB 1.2 [ 0.047]

11105535 40 [10.57] FC AB 1.2 [ 0.047]

11105536 65 [17.17] FC AB 1.2 [ 0.047]

© Danfoss | January 2018 BC00000211en-US0601 | 43


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75

Pressure drop to T (open spool in neutral)


P P
[psi] (bar)
4000 280

260
3600
240
3200 220

200
2800
180
2400
160
Pressure drop for
2000 140 PVBS 65 l/min
120
1600
100
1200 80

800 60

40
400
20

0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [US gal/min]

Fluid technical specification


Fluid temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended range -30 to 60°C [-22 to 140°F]

44 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Fluid technical specification (continued)


Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

© Danfoss | January 2018 BC00000211en-US0601 | 45


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Electric and/or Mechanical Actuation, Asymmetrical PVBS Spools


PVBS Electric and/or Mechanical Actuation asymmetrical spools with standard FC spools featuring either
throttled open or closed neutral position

Standard FC Spools Asymmetrical Throttled Open Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• A flow range from 5 – 65 l/min
• B flow range from 2.5 – 65 l/min

Part numbers for asymmetrical open neutral spools


Part number P→A P→B Flow Control Dead Band
l/min [US gal/min] l/min [US gal/min] mm [in]

11160953 5 [1.32] 2.5 [0.66] FC AB 1.2 [ 0.047]

11159472 5 [1.32] 10 [ 2.64] FC AB 1.2 [ 0.047]

11156160 15 [3.96] 25 [6.60] FC AB 1.2 [ 0.047]

11156158 25 [6.60] 40 [10.57] FC AB 1.2 [ 0.047]

11160957 40 [10.57] 25 [6.60] FC AB 1.2 [ 0.047]

11156155 40 [10.57] 65 [17.17] FC AB 1.2 [ 0.047]

Standard FC Spools Asymmetrical Closed Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• A flow range from 5 – 65 l/min
• B flow range from 2.5 – 65 l/min

Part numbers for asymmetrical closed neutral position spools


Part number P→A P→B Flow Control Dead Band
l/min [US gal/min] l/min [US gal/min] mm [in]

11109642 5 [1.32] 2.5 [0.66] FC AB 1.2 [ 0.047]

11109643 10 [ 2.64] 5 [1.32] FC AB 1.2 [ 0.047]

11156296 15 [3.96] 25 [6.60] FC AB 1.2 [ 0.047]

11109644 25 [6.60] 10 [ 2.64] FC AB 1.2 [ 0.047]

11109645 25 [6.60] 15 [3.96] FC AB 1.2 [ 0.047]

11156298 25 [6.60] 40 [10.57] FC AB 1.2 [ 0.047]

11109646 40 [10.57] 15 [3.96] FC AB 1.2 [ 0.047]

46 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Part numbers for asymmetrical closed neutral position spools (continued)


Part number P→A P→B Flow Control Dead Band
l/min [US gal/min] l/min [US gal/min] mm [in]

11109647 40 [10.57] 25 [6.60] FC AB 1.2 [ 0.047]

11109648 65 [17.17] 25 [6.60] FC AB 1.2 [ 0.047]

Fluid flow as a function of spool travel

P A (l/min) [US gal/min] P B


70
18
65 17
E
16
60
15
55
14
50 13
Spool types:
45 12
AA = 5/min
11 A = 10 l/min
40
10 D B = 15 l/min
E 35 9 C = 25 l/min
D = 40 l/min
30 8
E = 65 l/min
D 7
25
6 C
20
5
C B
15 4
B 3 A
10
2
A AA
5
AA 1

PVM (mm) PVM (mm)


8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 6
PVM [in] PVM [in]
0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24
Us Us
PVEH-FLA PVEH
UDC U DC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65
PVEH-U [V]
0.5 0.65

Pressure drop to T (open spool in neutral)


P P
[psi] (bar)
4000 280

260
3600
240
3200 220

200
2800
180
2400
160
Pressure drop for
2000 140 PVBS 65 l/min
120
1600
100
1200 80

800 60

40
400
20

0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [US gal/min]

© Danfoss | January 2018 BC00000211en-US0601 | 47


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Fluid technical specification


Fluid temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended range -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

48 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Hydraulic and/or Mechanical Actuation Symmetrical PVBS Spools


PVBS Hydraulic and/or Mechanical Actuation symmetrical spools with standard FC spools featuring either
throttled open or closed neutral position

Standard FC Spools Throttled Open Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• Spools with flow range from 5 - 65 l/min

Part numbers for symmetrical open neutral spools


Part number P → A/B Flow Control Dead Band
l/min [US gal/min] mm [in]

11109637 5 [1.32] FC AB 1.2 [ 0.047]

11109638 10 [2.64] FC AB 1.2 [ 0.047]

11109639 25 [6.60] FC AB 1.2 [ 0.047]

11109640 40 [10.57] FC AB 1.2 [ 0.047]

11109641 65 [17.17] FC AB 1.2 [ 0.047]

Standard FC Spools Closed Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• Spools with flow range from 5 - 65 l/min

Part numbers for symmetrical closed neutral position spools


Part number P → A/B Flow Control Dead Band
l/min [US gal/min] mm [in]

11109632 5 [1.32] FC AB 1.2 [ 0.047]

11109633 10 [2.64] FC AB 1.2 [ 0.047]

11109634 25 [6.60] FC AB 1.2 [ 0.047]

11109635 40 [10.57] FC AB 1.2 [ 0.047]

11109636 65 [17.17] FC AB 1.2 [ 0.047]

© Danfoss | January 2018 BC00000211en-US0601 | 49


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM PVM
(mm) 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 (mm)
PVM PVM
[in] 0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39 [in]
PVEH PVEH
PVEH-U 0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75 PVEH-U

Fluid technical specification


Fluid temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended range -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

50 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Hydraulic and/or Mechanical Actuation, Asymmetrical PVBS Spools


PVBS Hydraulic and/or Mechanical Actuation asymmetrical spools with standard FC spools featuring
either throttled open or closed neutral position

Standard FC Spools Asymmetrical Throttled Open Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• Spools with flow range from 5 - 65 l/min

Part numbers for asymmetrical open neutral spools


Part number P→A P→B Flow Control Dead Band
11189195 15 l/min [3.96 US gal/ 25 l/min [6.60 US gal/ FC AB 1.2 mm [0.047 in]
min] min]

Standard FC Spools Asymmetrical Closed Neutral Position


• 4-way, 3 positions
• Optional 4-way, 4 positions with the right PVM
• Flow control AB
• A flow range from 5 – 65 l/min
• B flow range from 2.5 – 65 l/min

Part numbers for asymmetrical closed neutral position spools


Part number P→A P→B Flow Control Dead Band
l/min [US gal/min] l/min [US gal/min] mm [in]

11146752 5 [1.32] 2.5 [0.66] FC AB 1.2 [ 0.047]

11146753 10 [ 2.64] 5 [1.32] FC AB 1.2 [ 0.047]

11467554 25 [6.60] 10 [ 2.64] FC AB 1.2 [ 0.047]

11146755 25 [6.60] 15 [3.96] FC AB 1.2 [ 0.047]

11146756 40 [10.57] 15 [3.96] FC AB 1.2 [ 0.047]

11146757 40 [10.57] 25 [6.60] FC AB 1.2 [ 0.047]

© Danfoss | January 2018 BC00000211en-US0601 | 51


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Fluid flow as a function of spool travel

P A (l/min) [US gal/min] P B


70
18
65 17
E
16
60
15
55
14
50 13
Spool types:
45 12
AA = 5/min
11 A = 10 l/min
40
10 D B = 15 l/min
E 35 9 C = 25 l/min
D = 40 l/min
30 8
E = 65 l/min
D 7
25
6 C
20
5
C B
15 4
B 3 A
10
2
A AA
5
AA 1

PVM (mm) PVM (mm)


8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 6
PVM [in] PVM [in]
0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24
Us Us
PVEH-FLA PVEH
UDC U DC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65
PVEH-U [V]
0.5 0.65

Pressure drop to T (open spool in neutral)


P P
[psi] (bar)
4000 280

260
3600
240
3200 220

200
2800
180
2400
160
Pressure drop for
2000 140 PVBS 65 l/min
120
1600
100
1200 80

800 60

40
400
20

0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [US gal/min]

Fluid technical specification


Fluid temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended range -30 to 60°C [-22 to 140°F]

52 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVBS Main Spools

Fluid technical specification (continued)


Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

© Danfoss | January 2018 BC00000211en-US0601 | 53


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVG 16 Manual, Hydraulic, Electro-hydraulic and Electrical Actuation overview.


PVG 16 Actuation can be done by:
• PVM Manual Actuation, see more PVM Manual Actuation on page 54
‒ PVMD cover, see more PVMD Cover on page 56
• PVH Hydraulic Actuation, see more PVH Hydraulic Actuation on page 57
• PVHC Electro-hydraulic Actuation, see more PVHC Electro-Hydraulic Actuation on page 59
• PVE Electrical Actuation, see more PVE Electrical Actuation on page 61
‒ PVEO, see more PVEO – ON/OFF Voltage Control Actuator on page 63
‒ PVEA, see more PVEA – Proportional Spool Control Actuator on page 66

PVM Manual Actuation


The PVM manual actuation cover is intended for use on any work section where the operator has to have
the ability to interact with the spool manually.
The adjustment screws are intended for limiting the spool travel and thereby the maximum achievable
flow.
PVM manual actuation cover

54 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVM manual actuation cover dimensions


51.7 [2.04]

183.8 [7.24]
85 [3.35]

60 [2.36] 13 [0.51] 45.6 [1.80]

Weight: 0,22 kg [0,49 lb]

Technical data
Spool displacement Torque
From neutral position PVM+PVMD
2.2 ± 0.2 N•m [5.0 ± 1.8 lb•in]
PVM+PVE
PVM+PVH 2.7 ± 0.2 N•m [23.9 ± 1.8 lb•in]
Max. spool travel PVM+PVMD
2.8 ± 0.2 N•m [6.3 ± 1.8 lb•in]
PVM+PVE
PVM+PVH 7.1 ± 0.2 N•m [62.8 ± 1.8 lb•in]
Standard control range 13.9°
Control lever range + float position 22.3°

Part numbers for PVM Manual Actuation


Part number Float Adjustment screws Lever base and lever
11107333 — — Yes

11107505 — — —

11107335 Yes — Yes

11107506 Yes — —

11107332 — Yes Yes

11107507 — Yes —

© Danfoss | January 2018 BC00000211en-US0601 | 55


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVMD Cover
The PVMD cover is used when work section is purely mechanical activated.
PVMD Cover

Dimensions, mm [in]
39 [1.54]
86 [3.39]

14 [0.55]

Part number and weight for PVMD Cover


Part number 11105518
Weight 1.5 kg [3.3 lb]

56 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVH Hydraulic Actuation


The PVH hydraulic actuation is intended for use on any work section where the operator wants to have a
possibility to interact with the main spool via a hydraulic joystick.
The hydraulic remote control lever should be connected directly to tank.

C Caution

Inlet with Hydraulic Pilot Pressure is needed.


PVH cover

PVH cover dimensions


19.5 [0.77]
86 [3.39]

27 [1.06]
29 [1.14]

39 [1.55] 28 [1.1]

Weight: 0,13 kg [0.29 lb]

© Danfoss | January 2018 BC00000211en-US0601 | 57


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

Fluid flow as a function of spool travel


P A (l/min) [US gal/min] P B
80 21

75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM PVM
(mm) 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 (mm)
PVM PVM
[in] 0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39 [in]
PVEH PVEH
PVEH-U 0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75 PVEH-U

Technical data
Main spool spring control pressure range 5 – 15 bar [73 – 218 psi]

Maximum pilot oil pressure 30 bar [435 psi]

Maximum pressure on port T 10 bar [145 psi]

Part numbers for PVH Hydraulic Actuation


Part number Material Connection
11108380 Aluminum G1/4" BSP
11108381 Aluminum 9/16"-18 UNF

58 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVHC Electro-Hydraulic Actuation


The PVHC is an electrical actuator module for main spool control. The PVHC control is done by dual Pulse
Width Modulated, high current supply 100-400 Hz PWM control signals. The spool position will shift
when conditions are changed such as temperature change.

C Caution
Inlet with Hydraulic Pilot Pressure is needed.
PVHC, Electro-Hydraulic Actuator

PVHC schematic

PVHC dimensions
92 [3.62]

100.5 [3.96] 39 [1.55]

© Danfoss | January 2018 BC00000211en-US0601 | 59


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVHC spool stroke vs current characteristics

PVHC characteristics – Spool stroke vs current

P A Spool stroke, mm P B

10

7 Ideal curve
6

4 Hysteresis
3

[Current in mA] [Current in mA]


@12V 1600 1400 1200 1000 800 600 400 200 0 200 400 600 800 1000 1200 1400 1600 @ 12V
@24V 800 700 600 500 400 300 200 100 0 100 200 300 400 500 600 700 800 @ 24V

P109250

The hysteresis is affected by viscosity, friction, flow forces, dither frequency and modulation frequency.
Dither frequency with a certain amplitude is needed for optimal application performance.

Technical data
Main spool spring control pressure range 5-15 bar [73-218 psi]

Pilot oil pressure range 20-25 bar [290-362 psi]

Max. pressure on port T 10 bar [145 psi]

Current Input 12V 0-1500 mA

Current Input 24V 0-750 mA

Ambient temperature range -30°C to 80°C [-22 °F to 176°F]

Temperature range -20°C to 80°C [-4 °F to 176°F]

Fluid cleanliness (according to ISO 4406) 23/19/16

Protection class IP 67

Connector type 2x2 DEUTSCH

PVHC part numbers


Part number Power supply Weight
11126941 12V 0,9 kg [1,98 lb]
11127535 24V 0,9 kg [1,98 lb]

60 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVE Electrical Actuation


The analog PVE Series 6 is an electro-hydraulic actuator used to control a single work section of a PVG
proportional valve group. The PVE Series 6 actuator program includes variants with different
performance levels and features.
The actuator positions the main spool in a PVG work section to control either the flow or the pressure of
the oil distributed to and from the work function. The control signal to the actuator is an analog voltage
signal, enabling the user to operate the work function remotely by means of a joystick, a controller or the
similar.
The electro-hydraulic solenoid valve bridge of the actuator is available in different designs utilizing
different regulation principles, depending on performance variant. The actuator positions the main spool
by distributing pilot oil pressure to either side of it, pressurizing one side by pilot pressure while relieving
the opposite side to tank and vice versa. All proportional actuators feature a closed- loop spool control
and continuous fault monitoring.
The analog PVE Series 6 actuator program for PVG 16 features two different main hydraulic principle
variants (PVEO and PVEA). The different hydraulic principles combined with the different solenoid valve
regulation principles determine whether the actuator controls the spool proportionally according to a
demand signal or ON/OFF according to a voltage signal. The voltage control characteristic of the PVE
Series 6 actuators is shown in the figure below to the left.
PVG 16 with PVEO sectional view

PVG 16 with PVEA sectional view

© Danfoss | January 2018 BC00000211en-US0601 | 61


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVE Series 6 Overview


ON/OFF voltage control, non-proportional functions Proportional spool control for work functions

PVEO Series 6 PVEA Series 6

For more information please see PVEO – ON/OFF Voltage


For more information please see PVEA – Proportional
Control Actuator on page 63.
Spool Control Actuator on page 66.

62 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVEO – ON/OFF Voltage Control Actuator


The PVEO actuator is a non-proportional ON/OFF control actuator with open-loop spool control primarily
used to control simple ON/OFF work functions where a proportional control of speed or oil flow is not a
requirement.
PVEO Series 6

All variants are available with following features:


• Neutral position or max. spool stroke according to control signal
• 12 VDC or 24 VDC supply voltage
• DEUTSCH connectors
• Standard PVE pilot oil pressure of 13.5 bar
• LED only indicating Power ON or Power OFF
• CAN-interface (-CI)
PVEO functionality diagram

A
B Pp

DI_B
DI_A
LED Circuit /
LED Microcontroller

Udc Power
Supply
SV1 SV2

Ramp Ramp
PVEO-DI LVDT
1 0 2

P109126

An energization of solenoid valve SV1 and a simultaneous de-energization of SV2 will cause the main
spool to move to the right direction and vice versa. If both SV1 and SV2 are energized or de-energized
simultaneously, the main spool stays locked in its neutral position.

© Danfoss | January 2018 BC00000211en-US0601 | 63


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVEO Series 6 schematic

PVEO Series 6 Dimensions


24 [0.94]
92 [3.62]

78.5 [3.09] 39 [1.54]

Weight: 0.7 kg [1.54 lb]

64 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVEO Technical Data


PVEO/PVEO-CI actuator technical specification and part numbers.

Control specifications
Description Type 12 VDC ± 10% 24 VDC ± 10%
Supply Voltage (UDC) Rated/range 11 to 15 VDC 12 to 30 VDC
Max. ripple 5% 5%
Current Consumption Typical 320 mA 160 mA

Technical data
Pilot pressure Nominal 13.5 bar [196 psi]
Minimum 10.0 bar [145 psi]
Maximum 15.0 bar [218 psi]
Fluid consumption Neutral 0.04 l/min [0.01 US gal/min]
Locked position 0.04 l/min [0.01 US gal/min]
Actuating 0.6 l/min [0.16 US gal/min]
Fluid temperature Ambient Storage -50 to +90°C [-58 to +194°F]
Ambient Operating -40 to +90°C [-40 to +194°F]
Fluid viscosity Operating range 12 to 75 mm2/sec [65 to 347 SUS]
Minimum 4 mm2/sec [39 SUS]
Maximum 460 mm2/sec [2128 SUS]
Fluid cleanliness Minimum 18/16/13 (according to ISO 4406)

LED characteristic
Color LED characteristic Description
Green Power ON

Part numbers for PVEO and PVEO-CI


Part number Type Connector Protection Class Voltage Interface
11106793 PVEO 1x4 DEUTSCH IP 65 12 VDC —

11106794 PVEO 1x4 DEUTSCH IP 65 24 VDC —

11124002 PVEO-CI 1x4 DEUTSCH IP 67 — J1939/ISObus

11149443 PVEO-CI 1x4 DEUTSCH IP 67 — CANopen

© Danfoss | January 2018 BC00000211en-US0601 | 65


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVEA – Proportional Spool Control Actuator


The PVEA actuator is a proportional actuator with closed-loop spool control primarily used to control
work functions.
PVEA Series 6

The PVEA functionality includes an electric circuit with a closed-loop logic. An integrated feedback
transducer measures spool movement in relation to the input signal. The PVEA features passive fault
monitoring, LED indicating fault state, error output pin and Power Save mode.
PVEA functionality

Power Save mode is entered when the command signal to the PVEA is below 15% of the supply voltage.
Entering Power Save mode will torn off the power to the solenoid valves. Power Save mode can be
identified by the LED blinking green at 1 Hz.
All variants available with following features:
• Neutral position or max. spool stroke according to control signal
• 11–32 VDC supply multi-voltage
• DEUTSCH connectors
• Standard PVE pilot oil pressure of 13.5 bar
• LED indicating error state and passive fault monitoring
• Float (-F) and CAN-interface (-CI)

66 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVEA (-F) Series 6 schematic

PVEA (-F) Series 6 dimensions


24 [0.94]
92 [3.62]

78.5 [3.09] 39 [1.54]

Weight: 0.7 kg [1.54 lb]

PVEA Technical Data


PVEA/PVEA-CI/PVEA-F actuator technical specification and part numbers.

Control specification
Description Type Value
Supply voltage (UDC) Rated/range 11 to 32 VDC
Max. ripple 15 bar [218 psi]
Signal voltage (US) Neutral 0.5 UDC
Q: P -> A 0.25 UDC
Q: P -> B 0.75 UDC
Current consumption @ 12 VDC 320 mA
@ 24 VDC 170 mA
Input impedance Rated 12 kΩ
Input capacitance Rated 100 µF

Technical data
Pilot pressure Nominal 13.5 bar [196 psi]
Minimum 10.0 bar [145 psi]
Maximum 15.0 bar [218 psi]

© Danfoss | January 2018 BC00000211en-US0601 | 67


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

Technical data (continued)


Fluid consumption Neutral 0.04 l/min [0.01 US gal/min]
Locked position 0.04 l/min [0.01 US gal/min]
Actuating 0.6 l/min [0.16 US gal/min]
Fluid temperature Ambient Storage -50 to +90°C [-58 to +194°F]
Ambient Operating -40 to +90°C [-40 to +194°F]
Fluid viscosity Operating range 12 to 75 mm2/sec [65 to 347 SUS]
Minimum 4 mm2/sec [39 SUS]
Maximum 460 mm2/sec [2128 SUS]
Fluid cleanliness Minimum 18/16/13 (according to ISO 4406)

LED characteristic
Color LED characteristic Description
Green constant Actuating

Green flashing 1 Hz Power Save mode

Red flashing 1 Hz External or float fault


Red constant Internal fault

Part numbers for PVEA/PVEA-F/PVEA-CI


Part number Type Connector Protection Voltage Interface Functionality
Class
11103692 PVEA 1x4 DEUTSCH IP 65 12 VDC — Standard

11106795 PVEA-F 1x4 DEUTSCH IP 65 24 VDC — Float B-port

11121945 PVEA-CI 1x4 DEUTSCH IP 67 — J1939/ISObus Standard

11149437 PVEA-CI 1x4 DEUTSCH IP 67 — CANopen Standard

68 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Actuation

PVG 16 Connector Variants


PVG 16 connector variants: PVEO, PVEA, PVEO-CI, PVEA-CI, PVEA-F and pin layout information.

1 x 4 DEUTSCH 2 x 4 DEUTSCH 1 x 6 DEUTSCH

3 4
2 3
2 3 1 4
2 5
1 6
1 4
2 3
1 4

Pin layout for PVEO, PVEA, PVEO-CI, PVEA-CI


PVE Type Connector Pin 1 Pin 2 Pin 3 Pin 4
PVEO 1 x 4 DEUTSCH NC 2 Vneg Vneg NC 4
PVEA 1 x 4 DEUTSCH Vi Sp Vneg Vbat
PVEO-CI, PVEA-CI 2 x 4 DEUTSCH CAN_H CAN_L Vbat Vneg

Pin layout for PVEA-F


Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
1 x 6 DEUTSCH Vi NC Vf Sp Vneg Vbat

© Danfoss | January 2018 BC00000211en-US0601 | 69


Technical Information
PVG 16 Proportional Valve Group

Fault Monitoring and Fault Reaction

All proportional control PVG 16 actuators feature:


• Integrated fault monitoring
• Detecting spool stroke inconsistencies
• Detecting internal hardware defects
• Detecting demand signal inconsistencies
• Fault reaction depending on the type of fault monitoring
‒ Generic
‒ Specific
The PVEA comes with a passive fault monitoring.

Passive fault monitoring


Passive fault monitoring does not disable the solenoid valves when an error is detected. It will continue
to operate despite that an error was detected. When the error no longer is registered the passive fault
monitoring will “forget” the error and continue as if the error was never there.
With a passive fault monitoring the following conditions will happen when an error is detected/occurs:
• The LED light will switch from green to red and the error pin output will go high
• The solenoid valves will continue operating at the set point given at the time of the error
‒ Only exception is if the error is caused by the supply voltage (UDC) being either above or below
the allowed range or if the temperature measured on the internal electronics board is higher than
allowed. In these cases, the solenoid valves will be disabled.
An overview of the error states and the reaction to the errors can be seen in the table Fault Reaction
Overview on page 71.

Generic Fault Reaction


All PVE actuators with fault monitoring are triggered by the following main events:

Control Signal Monitoring The Control signal voltage (US) is continuously monitored.
The permissible range is between 15% and 85% of the supply voltage (UDC).
Outside this range the PVE will switch into an error state. A disconnected US
pin (floating) is recognized as a neutral set point.
Transducer/LVDT Supervision The internal LVDT wires are monitored. If the signals are interrupted or short-
circuited, the PVE will switch into an error state.
Supervision of Spool Position The actual position must always correspond to the demanded position (US).
If the actual spool position is further out from neutral than the demanded
spool position or in opposite direction, the PVE will switch into an error state.
Spool position closer to neutral and in same direction will not cause an error
state – the situation is considered in control.
Float Position Monitoring Float position must be entered or left within a time limit.
A too high delay on the 1x6 pin float PVE will cause an error state – this is
relevant for the 1x6 pin PVEH-F actuators only.
Temperature Monitoring When the temperature is too high the PVE LED will light constant red and
solenoid valves will be disabled.

70 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

Fault Monitoring and Fault Reaction

Fault Reaction Overview

Description Monitoring LED Solenoid valves Error pin output Reaction time
(ms)
Spool not at setpoint Passive — High 250
Unable to reach float position Passive — High 250
UDC > max. Passive Disabled — 250
UDC < min. Passive ——————— Disabled — 250
US out of range Passive — High 250
LVDT error Passive — High 250
Temp > max. Passive Disabled High 250

© Danfoss | January 2018 BC00000211en-US0601 | 71


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

The PVG 16 PVS/PVSI end plates close off the valve stack section placed between them by placing them
at the end. Furthermore, the end plate is ensuring Load Sense (LS) is relieved to tank pressure when the
valve is not operated.
The PVS/PVSI end plate variants are based on a generic platform with a wide selection of additional
features, enabling you to tailor the PVS/PVSI to suit the demands of any hydraulic system.
The generic PVS end plates platform includes the following main variants:
• PVS/PVSI – Either aluminum or cast iron
• PVS/PVSI with LX-connection – Either aluminum or cast iron
• PVSI with P-, T-, LX- and M-connection – Cast iron
• PVST with T-connection – Steel

PVS end plates platform overview

PVS/PVSI PVS/PVSI with LX-connection

PVSI with P-, T-, LX- and M-connection PVST with T-connection

For more information about PVS/PVSI see:

PVS/PVSI on page 73
PVS/PVSI with LX-connection on page 75
PVSI with P-, T-, LX- and M-connection on page 77
PVST with T-connection on page 79

72 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

PVS/PVSI
The PVS/PVSI made of either aluminum or cast iron works as an end plate.
PVS/PVSI

PVS/PVSI schematic

PVS/PVSI dimensions
109.4 [4.31]

95 [3.74]

111 [4.37] 23 [0.91]

Weight: 0.47 kg [1.05 lb]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

© Danfoss | January 2018 BC00000211en-US0601 | 73


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

Part numbers for PVS/PVSI end plates


Part number Material Mounting feet
157B2000 Aluminum M8
157B2020 Aluminum 5/16–18
157B2014 Cast iron M8
157B2004 Cast Iron 5/16–18

74 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

PVS/PVSI with LX-connection


The PVS/PVSI made of either aluminum or cast iron works as an End Plate. The PVSI with LX connection
enables another valves LS pressure to be shuttled to the pump when needed. The LX port treads are with
BSP or UNF tread.
PVS/PVSI with LX-connection

PVS/PVSI with LX-connection schematic

Lx

PVS/PVSI with LX-connection dimensions


109.4 [4.31]

LX
G1/8
38.4 [1.51]

11.5 [0.45] 95 [3.74]


110 [4.33] 23 [0.9]

Weight: 0.47 kg [1.05 lb]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

© Danfoss | January 2018 BC00000211en-US0601 | 75


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

Part numbers for PVS/PVSI with LX-connection end plates


Part number Material LX-port Mounting feet
157B2011 Aluminum G1/8 M8
157B2021 Aluminum 3/8–24 5/16–18
157B2015 Cast iron G1/4 M8
157B2005 Cast Iron 1/2–20 5/16–18

76 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

PVSI with P-, T-, LX- and M-connection


PVSI is made of cast iron and works as an end plate. The PVSI with LX connection enables another valves
LS pressure to be shuttled to the pump when needed. The additional P- and T-port connections enables
an additional pump flow to a PVG 16 valve.
PVSI with P-, T-, LX- and M-connection

PVSI with P-, T-, LX- and M-connection schematic


T Lx

PVSI with P-, T-, LX- and M-connection dimensions


70.8 [2.79]
35.3 [1.39]
30.5 [1.20] 11.5 [0.45]
109.4 [4.31]
77.4 [3.05]
35.2 [1.386]

40 [1.57]
20.4 [0.8]

95 [3.74]

112.7 [4.44] 23 [0.91]

Weight: 0.47 kg [1.05 lb]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]

© Danfoss | January 2018 BC00000211en-US0601 | 77


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

Technical data (continued)


Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

Part number for PVSI with P-, T-, LX-, M-ports


Part number P-port T-port LX-port M-port Mounting feet
157B2920 G3/8 G1/2 G1/8 G1/4 M8

78 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

PVST with T-connection


The PVG 16 PVST iron end plate closes off the valve stack section placed between them by placing it at
the end. Furthermore, the end plate is ensuring Load Sense (LS) is relieved to tank pressure when the
valve is not operated.
PVST with T-connection

PVST schematic with T-connection


T

PVST with T-connection dimensions


110 [4.33]
77.4 [3.05]

16 [0.63] 95 [3.74] 32 [1.26]


110 [4.33]

Weight: 0.47 kg [1.05 lb]

Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)

© Danfoss | January 2018 BC00000211en-US0601 | 79


Technical Information
PVG 16 Proportional Valve Group

PVS End Plates

Part numbers for PVST with T-connection end plates


Part number Material T-port Mounting feet
157B2500 Steel G1/2 M8
157B2520 Steel 7/8–14 5/16–18

When using a PVST (157B2500 or 157B2520) it is not possible to use the LS A/B fitting in the bottom of
the PVG section next to the PVST.

80 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVAS Stay Bolts

PVAS Stay Bolts kit for various PVG combinations consist of three tie rods, six washers, six nuts and O-ring.
Use the guide and reference tables how to choose PVAS kit.
The tie rods are inserted through the entire length of the PVG valve stack. The nuts are tightened at the
pump side and at the end plate.
To find the PVAS kit that fits your PVG 16 valve stack, you need to go to the table PVG 16 modules total
length and weight on page 82 and find the length. Then go to the table PVAS Part Numbers on page 82
and find the matching part number.
For stay bolts for a PVG 32/16 combination, see this PVG 32/16 Combinations on page 83.
Stay bolts for PVG 256/128/32/16 combinations consist of two different kits. See PVG 256/128/32/16
Combinations on page 84 to find the right kits for your combination.
Combinations with PVG 100 and PVG 120 requires special PVAS kits. These are not included in the PVAS
table.

© Danfoss | January 2018 BC00000211en-US0601 | 81


Technical Information
PVG 16 Proportional Valve Group

PVAS Stay Bolts

PVAS Part Numbers


PVAS part numbers according to accumulated length interval PVG 16.

PVAS part numbers


Length, mm [in] Part number Length, mm [in] Part number
20 – 48 [0.79 – 1.89] 11188219 361 – 372 [14.21 – 14.65] 11188205
49 – 60 [1.93 – 2.36] 11188218 373 – 384 [14.69 – 15.12] 157B8026
61 – 72 [2.40 – 2.83] 157B8000 385 – 396 [15.16 – 15.59] 11188204
73 – 84 [2.87 – 3.31] 11188217 397 – 408 [15.63 – 16.06] 157B8007
85 – 96 [3.35 – 3.78] 157B8031 409 – 420 [16.10 – 16.54] 11188203
97 – 108 [3.82 – 4.25] 11188216 421 – 432 [16.58 – 17.01] 157B8027
109 – 120 [4.29 – 4.72] 157B8001 433 – 444 [17.05 – 17.48] 11188202
121 – 132 [4.76 – 5.20] 11188215 445 – 456 [17.52 – 17.95] 157B8008
133 – 144 [5.24 – 5.67] 157B8021 457 – 468 [17.99 – 18.43] 11188201
145 – 156 [5.71 – 6.14] 11188214 469 – 480 [18.47 – 18.90] 157B8028
157 – 168 [6.18 – 6.61] 157B8002 481 - 492 [18.94 – 19.37] 11188200
169 – 180 [6.65 – 7.09] 11188213 493 – 504 [19.41 – 19.84] 157B8009
181 – 192 [7.13 – 7.56] 157B8022 505 – 516 [19.88 – 20.31] 11188199
193 – 204 [7.60 – 8.03] 11188212 517 – 528 [20.35 – 20.79] 157B8029
205 – 216 [8.07 – 8.50] 157B8003 529 – 540 [20.83 – 21.26] 11188198
217 – 228 [8.54 – 8.98] 11188211 541 – 552 [21.30 – 21.73] 157B8010
229 – 240 [9.02 – 9.45] 157B8023 553 – 564 [21.77 - 22.20] 11188197
241 – 252 [9.49 – 9.92] 11188210 565 – 576 [22.24 – 22.68] 157B8030
253 – 264 [9.96 – 10.39] 157B8004 577 – 588 [22.72 – 23.15] 11188196
265 – 276 [10.43 – 10.87] 11188209 589 – 600 [23.19 – 23.62] 157B8061
277 – 288 [10.91 – 11.34] 157B8024 601 – 612 [23.66 – 24.09] 11188195
289 – 300 [11.38 – 11.81] 11188208 613 – 624 [24.13 – 24.57] 157B8081
301 – 312 [11.85 – 12.28] 157B8005 625 – 636 [24.61 – 25.04] 11188194
313 – 324 [12.32 – 12.76] 11188207 637 – 648 [25.08 – 25.51] 157B8062
325 – 336 [12.80 – 13.23] 157B8025 649 – 660 [25.55 – 25.98] 11188189
337 – 348 [13.27 – 13.70] 11188206 661 - 672 [26.02 – 26.46] 157B8082
349 – 360 [13.74 – 14.17] 157B8006

PVG 16 modules total length and weight


The table of PVB 16 modules consists of total length depending on the amount of valve groups with
weight.

No. of 1 2 3 4 5 6 7 8 9 10 11 12
PVB 16
Length 140 189 213 262 311 336 385 434 458 507 551 576
mm [in] [5.51] [7.44] [8.39] [10.31] [12.24] [13.23] [15.16] [17.09] [18.03] [19.96] [21.69] [22.68]
Weight* 7,2 10,9 14,6 18,3 22 25,7 29,4 33,1 36,8 40,5 44,2 47,9
kg [lb] [15.9] [24] [32.2] [40.3] [48.5] [56.7] [64.8] [73] [81.1] [89.3] [97.4] [105.6]
* Weight is for a PVG 16 with a PVE on each working section and is only approximate.

82 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVAS Stay Bolts

PVG 32/16 Combinations


The table of PVB 32 and PVB 16 modules combination, the total length depending on the amount of
valve groups.

PVB 16
Modules 1 2 3 4 5 6 7 8 9 10 11
mm [in]
1 189 238 262 311 360 409 434 483 507 551 600
[7.44] [9.37] [10.31] [12.24] [14.17] [16.10] [17.09] [19.02] [19.96] [21.69] [23.62]
2 238 287 311 360 409 434 483 507 551 600 646
[9.37] [11.30] [12.24] [14.17] [16.10] [17.09] [19.02] [19.96] [21.69] [23.62] [25.43]
3 287 336 360 409 458 483 527 576 600 646 -
[11.30] [13.23] [14.17] [16.10] [18.03] [19.02] [20.75] [22.68] [23.62] [25.43]
4 336 385 409 458 483 527 576 622 646 - -
[13.23] [15.16] [16.10] [18.03] [19.02] [20.75] [22.68] [24.49] [25.43]
5 385 434 458 507 551 576 622 670 - - -
[15.16] [17.09] [18.03] [19.96] [21.69] [22.68] [24.49] [26.38]
PVB 6 434 483 507 551 600 622 670 - - - -
32 [17.09] [19.02] [19.96] [21.69] [23.62] [24.49]
7 483 527 551 600 646 - - - - - -
[19.02] [20.75] [21.69] [23.62] [25.43]
8 527 576 600 646 - - - - - - -
[20.75] [22.68] [23.62] [25.43]
9 576 622 646 - - - - - - - -
[22.68] [24.49] [25.43]
10 622 670 - - - - - - - - -
[24.49] [26.38]
11 670 - - - - - - - - - -
[26.38]

© Danfoss | January 2018 BC00000211en-US0601 | 83


Technical Information
PVG 16 Proportional Valve Group

PVAS Stay Bolts

PVG 256/128/32/16 Combinations


The tables of PVB 256/128, 32/16 modules, total length depending on the amount of valve groups.
Stay bolts for PVG 128/256/32/16 combinations consist of 2 different kits:
1. For PVAS containing 2 stay bolts – please look in the Table 1 below and use the part number before
the + symbol.
2. For PVAS containing 3 stay bolts – please look in Table 1 below and write down the length in
millimeters which is the number after the + symbol. Next you add the number from Table 2 below.
Now find the part number for the needed stay bolts in the table PVAS Part Numbers on page 82.

O-rings are a part of the PVAS kits – no additional part number needed.

C Caution

It is not possible to do combinations exceeding 672 mm.

Example
For 2 PVB 256 and 1 PVB 128 and 1 PVB 32 and 2 PVB 16: PVAS 1 Part number = 11187681 from Table 1.
PVAS 2 = 278 mm from Table 1 + 152 mm from Table 2= 278+152 =430 mm which equals 157B8027 in
the PVAS table.

Table 1 – PVG 256/128 combinations


PVB 256
Modules 0 1 2 3 4 5 6
(mm)
0 36 11187672 + 11187673 + 11187674 + 11187675 + 11187676 + 11187677 +
123 209 295 381 467 553
1 11187320 + 11187677 + 11187681 + 11187684 + 11187685 + 11187687 + -
103 189 278 361 447 533
2 11187617 + 11187678 + 11187682 + 11187686 + 11187691 + 11187692 + -
169 255 341 427 513 599
3 11187655 + 11187679 + 11187683 + 11187693 + 11187694 + - -
235 321 407 493 579
PVB 4 11187656 + 11187680 + 11187696 + 11187697 + - - -
128 301 387 473 559
5 11187658 + 11187699 + 11187687 + - - - -
367 453 539
6 11187702 + 11187703 + 11187704 + - - - -
433 519 605
7 11187705 + 1187694 + - - - - -
499 585
8 11187697 + - - - - - -
565

84 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVAS Stay Bolts

Table 2 – PVG 32/16 combinations


PVB 16
Modules (mm) 0 1 2 3 4 5 6 7 8 9 10
0 - 64 104 144 184 224 264 304 344 384 424
1 72 112 152 192 232 272 312 352 392 432 -
2 120 160 200 240 280 320 360 400 440 - -
3 168 208 248 288 328 368 408 448 - - -
4 216 256 296 236 276 416 456 - - - -
PVB 32 5 264 304 344 384 424 464 - - - - -
6 312 352 392 432 472 - - - - - -
7 360 400 440 480 - - - - - - -
8 408 448 488 - - - - - - - -
9 456 496 - - - - - - - - -
10 504 - - - - - - - - - -

© Danfoss | January 2018 BC00000211en-US0601 | 85


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVG 16 Dimensions
The table of PVB 16 valve stack dimensions overview table with accompanying drawing.

22.5°

191.3 [7.53]
121.6 [4.79]

95 [3.74]
78.5 [3.09] 110 [4.33] 60 [2.36]
261.5 [10.3]
303.8 [11.96]

L1
L2
73.5 [2.89]
62.5 [2.46]

25 [0.98]

18.5 [0.73]
38.5 [1.52]
71.5 [2.81]
91 [3.58]

PVB 16 dimensions (12 sections)


Number of 1 2 3 4 5 6 7 8 9 10 11 12
PVB 16
L1 mm 74 114 154 194 234 274 314 354 394 434 474 514
[in] [2.91] [4.49] [6.06] [7.64] [9.21] [10.79] [12.36] [13.94] [15.51] [17.09] [18.66] [20.24]
L2 mm 140 189 213 262 311 336 385 434 458 507 551 576
[in] [5.51] [7.44] [8.39] [10.31] [12.24] [13.23] [15.16] [17.09] [18.03] [19.96] [21.69] [22.68]

86 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVG 32/16 Dimensions


The table of PVB 32 and PVB 16 combination valve stack dimensions overview table with accompanying
drawing.

L1
L2
95 [3.74]

PVB 32/16 combination valve stack dimensions, mm [in]


Number Number of PVB 16 modules
of PVB 32
(down) 1 2 3 4 5 6 7 8 9 10 11

1 L1 122 162 202 242 282 322 362 402 442 482 522
[4.80] [6.38] [7.95] [9.53] [11.10] [12.68] [14.25] [15.83] [17.40] [18.98] [20.55]
L2 189 238 262 311 360 385 434 483 507 551 600
[7.44] [9.37] [10.31] [12.24] [14.17] [15.16] [17.09] [19.02] [19.96] [21.69] [23.62]
2 L1 170 210 250 290 330 370 410 450 490 530 570
[6.69] [8.27] [9.84] [11.42] [12.99] [14.57] [16.14] [17.72] [19.29] [20.87] [22.44]
L2 238 287 311 360 409 434 483 507 551 600 646
[9.37] [11.30] [12.24] [14.17] [16.10] [17.09] [19.02] [19.96] [21.69] [23.62] [25.43]
3 L1 218 258 298 338 378 418 458 498 538 578 -
[8.58] [10.16] [11.73] [13.31] [14.88] [16.46] [18.03] [19.61] [21.18] [22.76]
L2 287 336 360 409 458 483 527 576 600 646 -
[11.30] [13.23] [14.17] [16.10] [18.03] [19.02] [20.75] [22.68] [23.62] [25.43]
4 L1 266 306 346 386 426 466 506 546 586 - -
[10.47] [12.05] [13.62] [15.20] [16.77] [18.35] [19.92] [21.50] [23.07]
L2 336 385 409 458 483 527 576 622 646 - -
[13.23] [15.16] [16.10] [18.03] [19.02] [20.75] [22.68] [24.49] [25.43]
5 L1 314 354 394 434 474 514 554 594 - - -
[12.36] [13.94] [15.51] [17.09] [18.66] [20.24] [21.81] [23.39]
L2 385 434 458 507 551 576 622 670 - - -
[15.16] [17.09] [18.03] [19.96] [21.69] [22.68] [24.49] [26.38]
6 L1 362 402 442 482 522 562 602 - - - -
[14.25] [15.83] [17.40] [18.98] [20.55] [22.13] [23.70]
L2 434 483 507 551 600 622 670 - - - -
[17.09] [19.02] [19.96] [21.69] [23.62] [24.49] [26.38]
7 L1 410 450 490 530 570 610 - - - - -
[16.14] [17.72] [19.29] [20.87] [22.44] [24.02]
L2 483 527 551 600 646 670 - - - - -
[19.02] [20.75] [21.69] [23.62] [25.43] [26.38]
8 L1 458 498 538 578 - - - - - - -
[18.03] [19.61] [21.18] [22.76]
L2 527 576 600 646 - - - - - - -
[20.75] [22.68] [23.62] [25.43]

© Danfoss | January 2018 BC00000211en-US0601 | 87


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVB 32/16 combination valve stack dimensions, mm [in] (continued)


Number Number of PVB 16 modules
of PVB 32
(down) 1 2 3 4 5 6 7 8 9 10 11

9 L1 506 546 586 - - - - - - - -


[19.92] [21.50] [23.07]
L2 576 622 646 - - - - - - - -
[22.68] [24.49] [25.43]
10 L1 554 594 - - - - - - - - -
[21.81] [23.39]
L2 622 670 - - - - - - - - -
[24.49] [26.38]
11 L1 602 - - - - - - - - - -
[23.70]
L2 670 - - - - - - - - - -
[26.38]

Weight for a PVG 32/16 valve stack


The combined weight of a PVG 32/16 valve stack can be defined like this:
(Numbers of PVB 32 x 4,25) + (numbers of PVB 16 x 3,67) + 3,6 = Weight in kg
(Numbers of PVB 32 x 9.37) + (numbers of PVB 16 x 8.09) + 7.95 = Weight in lb

88 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVG 100/16 Dimensions


The table of PVB 100 and PVB 16 combination valve stack dimensions overview table with accompanying
drawing.

L3
L1
L2

PVB 100/16 combination valve stack dimensions, mm [in]


Number of Number of PVB 16
PVB 100
(down) 1 2 3 4 5 6 7 8 9 10 11

1 L1 172 212 252 292 332 372 412 452 492 532 572
[6.77] [8.35] [9.92] [11.50] [13.07] [14.65] [16.22] [17.80] [19.37] [20.94] [22.52]
L2 236 285 311 358 407 432 481 530 554 603 652
[9.29] [11.22] [12.24] [14.09] [16.02] [17.01] [18.94] [20.87] [21.81] [23.74] [25.67]
L3 80 [3.15]
2 L1 220 260 300 340 380 420 460 500 540 580 620
[8.66] [10.24] [11.81] [13.39] [14.96] [16.54] [18.11] [19.69] [21.26] [22.83] [24.41]
L2 284 333 359 406 455 480 529 578 602 651 700
[11.18] [13.11] [14.13] [15.98] [17.91] [18.90] [20.83] [22.76] [23.70] [25.63] [27.56]
L3 128 [5.04]
3 L1 268 308 348 388 428 468 508 548 588 628 668
[10.55] [12.13] [13.70] [15.28] [16.85] [18.43] [20.00] [21.57] [23.15] [24.72] [26.30]
L2 332 381 407 454 503 528 577 626 650 699 748
[13.07] [15.00] [16.02] [17.87] [19.80] [20.79] [22.72] [24.65] [25.59] [27.52] [29.45]
L3 176 [6.93]
4 L1 316 256 396 436 476 516 556 596 636 676 716
[12.44] [10.08] [15.59] [17.17] [18.74] [20.31] [21.89] [23.46] [25.04] [26.61] [28.19]
L2 380 429 455 502 551 576 625 674 698 747 796
[14.96] [16.89] [17.91] [19.76] [21.69] [22.68] [24.61] [26.54] [27.48] [29.41] [31.34]
L3 224 [8.82]

© Danfoss | January 2018 BC00000211en-US0601 | 89


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVB 100/16 combination valve stack dimensions, mm [in] (continued)


Number of Number of PVB 16
PVB 100
(down) 1 2 3 4 5 6 7 8 9 10 11

5 L1 364 404 444 484 524 564 604 644 684 724 -
[14.33] [15.91] [17.48] [19.06] [20.63] [22.20] [23.78] [25.35] [26.93] [28.50]
L2 428 477 503 550 599 624 673 722 746 795 -
[16.85] [18.78] [19.80] [21.65] [23.58] [24.57] [26.50] [28.43] [29.37] [31.30]
L3 272 [10.71]
6 L1 412 452 492 532 572 612 652 692 732 - -
[16.22] [17.80] [19.37] [20.94] [22.52] [24.09] [25.67] [27.24] [28.82]
L2 476 525 551 598 647 672 721 770 794 - -
[18.74] [20.67] [21.69] [23.54] [25.47] [26.46] [28.39] [30.31] [31.26]
L3 320 [12.60]
7 L1 460 500 540 580 620 660 700 740 - - -
[18.11] [19.69] [21.26] [22.83] [24.41] [25.98] [27.56] [29.13]
L2 524 573 599 646 695 720 769 818 - - -
[20.63] [22.56] [23.58] [25.43] [27.36] [28.35] [30.28] [32.20]
L3 368 [14.49]
8 L1 508 548 588 628 668 708 748 - - - -
[20.00] [21.57] [23.15] [24.72] [26.30] [27.87] [29.45]
L2 572 621 647 694 743 768 817 - - - -
[22.52] [24.45] [25.47] [27.32] [29.25] [30.24] [32.17]
L3 416 [16.38]

Weight for a PVG 100/16 valve stack


The combined weight of a PVG 100/16 valve stack can be defined like this:
(Numbers of PVB 100 x 7) + (numbers of PVB 16 x 3.67) + 10 = Weight in kg
(Numbers of PVB 100 x 9.37) + (numbers of PVB 16 x 8.09) + 22 = Weight in lb

90 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVG 120/16 Dimensions


The table of PVB 120 and PVB 16 combination valve stack dimensions overview table with accompanying
drawing.

L3
L1
L2

PVB 120/16 combination valve stack dimensions, mm [in]


Number of Number of PVB 16 modules
PVB 120
(down) 1 2 3 4 5 6 7 8 9 10 11

1 L1 284 324 364 404 444 484 524 564 604 644 684
[11.18] [12.76] [14.33] [15.91] [17.48] [19.06] [20.63] [22.20] [23.78] [25.35] [26.93]
L2 348 397 421 470 519 544 593 642 666 715 759
[13.70] [15.63] [16.57] [18.50] [20.43] [21.42] [23.35] [25.28] [26.22] [28.15] [29.88]
L3 80 [3.15]
2 L1 351 391 431 471 511 551 591 631 671 711 751
[13.82] [15.39] [16.97] [18.54] [20.12] [21.69] [23.27] [24.84] [26.42] [27.99] [29.57]
L2 413 462 486 535 584 609 658 707 731 780 824
[16.26] [18.19] [19.13] [21.06] [22.99] [23.98] [25.91] [27.83] [28.78] [30.71] [32.44]
L3 128 [5.04]
3 L1 418 458 498 538 578 618 658 698 738 778 818
[16.46] [18.03] [19.61] [21.18] [22.76] [24.33] [25.91] [27.48] [29.06] [30.63] [32.20]
L2 478 527 551 600 649 674 723 772 796 845 889
[18.82] [20.75] [21.69] [23.62] [25.55] [26.54] [28.46] [30.39] [31.34] [33.27] [35.00]
L3 176 [6.93]
4 L1 485 525 565 605 545 685 725 765 805 845 885
[19.09] [20.67] [22.24] [23.82] [21.46] [26.97] [28.54] [30.12] [31.69] [33.27] [34.84]
L2 543 592 616 665 714 739 788 837 861 910 954
[21.38] [23.31] [24.25] [26.18] [28.11] [29.09] [31.02] [32.95] [33.9] [35.83] [37.56]
L3 224 [8.82]

© Danfoss | January 2018 BC00000211en-US0601 | 91


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVB 120/16 combination valve stack dimensions, mm [in] (continued)


Number of Number of PVB 16 modules
PVB 120
(down) 1 2 3 4 5 6 7 8 9 10 11

5 L1 552 592 632 672 712 752 792 832 872 912 -
[21.73] [23.31] [24.8] [26.46] [28.03] [29.61] [31.18] [32.76] [34.33] [35.91]
L2 608 657 681 730 779 804 853 902 926 975 -
[23.94] [25.87] [26.81] [28.74] [30.67] [31.65] [33.58] [35.51] [36.46] [38.39]
L3 272 [10.71]
6 L1 619 659 699 739 779 819 859 899 939 - -
[24.37] [25.94] [27.52] [29.09] [30.67] [32.24] [33.82] [35.39] [36.97]
L2 673 722 746 795 844 869 918 967 991 - -
[26.50] [28.43] [29.37] [31.30] [33.23] [34.21] [36.14] [38.07] [39.02]
L3 320 [12.60]
7 L1 686 726 766 806 846 886 926 966 - - -
[27.01] [28.58] [30.16] [31.73] [33.31] [34.88] [36.46] [38.03]
L2 738 787 811 860 909 934 983 1032 - - -
[29.06] [30.98] [31.93] [33.86] [35.79] [36.77] [38.70] [40.63]
L3 368 [14.49]
8 L1 753 793 833 873 913 953 993 - - - -
[29.65] [31.22] [32.80] [34.37] [35.94] [37.52] [39.09]
L2 803 852 876 925 974 999 1048 - - - -
[31.61] [33.54] [34.49] [36.42] [38.35] [39.33] [41.26]
L3 639 [25.16]

There is a horizontal difference 62.5 mm [2.46 in] in the mounting plane of the PVG 120/PVG 16.

The PVG 120 interface module is large sized.


It is necessary to have at least one PVG 32 module between the PVGI and the first PVG 16 slice.

92 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVG 128/16 Dimensions


The table of PVB 128 and PVB 16 combination valve stack dimensions overview table with accompanying
drawing.
95 [3.74]

L1

L2
L3
132 [5.20]

PVB 128/PVB 16 valve stack dimensions, mm [in]


Number Number of PVB 16
of PVB
128 1 2 3 4 5 6 7 8 9 10 11
(down)
1 L1 173 213 253 293 333 373 413 453 493 533 573
[6.81] [8.39] [9.96] [11.54] [13.11] [14.69] [16.26] [17.83] [19.41] [20.98] [22.56]
L2 297,5 346,5 382,5 418,5 467,5 503,5 540,5 588,5 625,5 661,5 685,5
[11.71] [13.64] [15.06] [16.48] [18.41] [19.82] [21.28] [23.17] [24.63] [26.04] [26.99]
L3 98,5 [3.88]
2 L1 239 279 319 359 399 439 479 519 559 599 —
[9.41] [10.98] [12.56] [14.13] [15.71] [17.28] [18.86] [20.43] [22.01] [23.58]
L2 370,5 406,5 455,5 491,5 528,5 576,5 588,5 649,5 697,5 734,5 —
[14.59] [16.00] [17.93] [19.35] [20.81] [22.70] [23.17] [25.57] [27.46] [28.92]
L3 164,5 [6.48]
3 L1 305 345 385 425 465 505 545 585 — — —
[12.01] [13.58] [15.16] [16.73] [18.31] [19.88] [21.46] [23.03]
L2 431,5 479,5 515,5 552,5 600,5 637,5 673,5 722,5 — — —
[16.99] [18.88] [20.30] [21.75] [23.64] [25.10] [26.52] [28.44]
L3 230,5 [9.07]
4 L1 371 411 451 491 531 571 611 — — — —
[14.61] [16.18] [17.76] [19.33] [20.91] [22.48] [24.06]
L2 503,5 540,5 588,5 625,5 661,5 709,5 746,5 — — — —
[19.82] [21.28] [23.17] [24.63] [26.04] [27.93] [29.39]
L3 296,5 [11.67]
5 L1 437 477 517 557 597 — — — — — —
[17.02] [18.78] [20.35] [21.93] [23.50]
L2 564,5 612,5 649,5 685,5 734,5 — — — — — —
[22.22] [24.11] [25.57] [26.99] [28.92]
L3 362,5 [14.27]

© Danfoss | January 2018 BC00000211en-US0601 | 93


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVB 128/PVB 16 valve stack dimensions, mm [in] (continued)


Number Number of PVB 16
of PVB
128 1 2 3 4 5 6 7 8 9 10 11
(down)
6 L1 503 543 583 — — — — — — — —
[19.80] [21.38] [22.95]
L2 637,5 673,5 722,5 — — — — — — — —
[25.10] [26.52] [28.44]
L3 428,5 [16.87]
7 L1 569 609 — — — — — — — — —
[22.40] [23.98]
L2 697,5 746,5 — — — — — — — — —
[27.46] [29.39]
L3 494,5 [19.47]

Weight for a PVG 128/16 valve stack


The combined weight of a PVG 128/16 valve stack can be defined like this:
(Numbers of PVB 128 x 16.9) + (numbers of PVB 16 x 3,67) + 17.5 = Weight in kg
(Numbers of PVB 128 x 37.26) + (numbers of PVB 16 x 8.09) + 38.6 = Weight in lb

94 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

PVG 256/16 Dimensions


The table of PVB 256 and PVB 16 combination valve stack dimensions overview table with accompanying
drawing.
95 [3.74]

L1

L2
L3
132 [5.20]

PVB 256/16 combination valve stack dimensions, mm [in]


Number Number of PVB 16
of PVB
256 1 2 3 4 5 6 7 8 9 10 11
(down)
1 L1 193 233 273 313 353 393 433 473 513 553 593
[7.60] [9.17] [10.75] [12.32] [13.90] [15.47] [17.05] [18.62] [20.20] [21.78] [23.35]
L2 321,5 358,5 406,5 443,5 479,5 528,5 564,5 600,5 649,5 685,5 734,5
[12.66] [14.11] [16.01] [17.46] [18.88] [20.81] [22.22] [23.64] [25.57] [26.99] [28.92]
L3 118,5 [4.67]
2 L1 285 325 365 405 445 485 525 565 605 — —
[11.22] [12.80] [14.37] [15.94] [17.52] [19.09] [20.67] [22.224 [23.82]
]
L2 406,5 455,5 491,5 528,5 576,5 612,5 649,5 697,5 734,5 — —
[16.01] [17.93] [19.35] [20.81] [22.70] [24.11] [25.57] [27.46] [28.92]
L3 204,5 [8.05]
3 L1 371 411 451 491 531 571 611 — — — —
[14.61] [16.18] [17.76] [19.33] [20.91] [22.48] [24.06]
L2 491,5 540,5 576,5 612,5 661,5 697,5 734,5 — — — —
[19.35] [21.28] [22.70] [24.11] [26.04] [27.46] [28.92]
L3 290,5 [11.44]
4 L1 457 497 537 577 617 — — — — — —
[17.99] [19.57] [21.14] [22.72] [24.29]
L2 588,5 625,5 661,5 709,5 746,5 — — — — — —
[23.17] [24.63] [26.04] [27.93] [29.39]
L3 376,5 [14.82]
5 L1 543 583 623 — — — — — — — —
[21.38] [22.95] [24.53]
L2 673,5 709,5 746,5 — — — — — — — —
[26.52 [27.93] [29.93]
L3 462,5 [18.21]

© Danfoss | January 2018 BC00000211en-US0601 | 95


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Combinations Valve Stack Dimensions

Weight for a PVG 256/16 valve stack


The combined weight of a PVG 256/16 valve stack can be defined like this:
(Numbers of PVB 256 x 20.9) + (numbers of PVB 16 x 3,67) + 17.5 = Weight in kg
(Numbers of PVB 256 x 40.08) + (numbers of PVB 16 x 8.09) + 38.6 = Weight in lb

96 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Applications Schematics

PVG 16 Schematic with Basic End Plate


The schematic example of PVG 16 with basic end plate.

T
M LS

© Danfoss | January 2018 BC00000211en-US0601 | 97


Technical Information
PVG 16 Proportional Valve Group

PVG 16 Applications Schematics

PVG 16 with P- and T-connection end plate


The schematic example of PVG 16 with P- and T-connection end plate.

M
B

T
M LS

98 | © Danfoss | January 2018 BC00000211en-US0601


Technical Information
PVG 16 Proportional Valve Group

© Danfoss | January 2018 BC00000211en-US0601 | 99


Products we offer: Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions
• Bent Axis Motors
that excel in the harsh operating conditions of the mobile off-highway market. Building on
• Closed Circuit Axial Piston our extensive applications expertise, we work closely with our customers to ensure
Pumps and Motors exceptional performance for a broad range of off-highway vehicles.
• Displays
We help OEMs around the world speed up system development, reduce costs and bring
• Electrohydraulic Power vehicles to market faster.
Steering
• Electrohydraulics Danfoss – Your Strongest Partner in Mobile Hydraulics.

• Hydraulic Power Steering Go to www.powersolutions.danfoss.com for further product information.


• Integrated Systems Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support
• Joysticks and Control for our customers, ensuring the best possible solutions for outstanding performance. And
Handles with an extensive network of Global Service Partners, we also provide comprehensive global
service for all of our components.
• Microcontrollers and
Software Please contact the Danfoss Power Solution representative nearest you.
• Open Circuit Axial Piston
Pumps
• Orbital Motors
• PLUS+1® GUIDE
• Proportional Valves
• Sensors
• Steering
• Transit Mixer Drives

Comatrol
www.comatrol.com Local address:
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com

Danfoss
Power Solutions Trading
Danfoss Danfoss Danfoss (Shanghai) Co., Ltd.
Power Solutions (US) Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

© Danfoss | January 2018 BC00000211en-US0601