pvg16 New
pvg16 New
pvg16 New
powersolutions.danfoss.com
Technical Information
PVG 16 Proportional Valve Group
February 2016 Drawing was updated in topic: How to select the correct spool 0301
Contents
General Information
General Description.........................................................................................................................................................................5
PVG 16 Features................................................................................................................................................................................ 5
PVG 16 Modules Overview............................................................................................................................................................6
PVP Inlet Modules
Open Center PVP.............................................................................................................................................................................. 8
Open Center PVP with PPRV...................................................................................................................................................... 10
Open center PVP with PPRV and adjustment spool..........................................................................................................13
Closed Center PVP......................................................................................................................................................................... 16
Closed Center PVP with PPRV....................................................................................................................................................18
PVPX, Electrical LS Pressure Unloading Valve......................................................................................................................20
PVB Basic Modules
Compensated PVB......................................................................................................................................................................... 24
Compensated PVB with PVLP/PVLA........................................................................................................................................27
Compensated PVB with LS A/B................................................................................................................................................. 31
Uncompensated PVB....................................................................................................................................................................34
Uncompensated PVB with PVLP...............................................................................................................................................36
PVLP, Shock/Anti-Cavitation and PVLA, Suction Valves...................................................................................................39
PVBS Main Spools
Electric and/or Mechanical Actuation, Symmetrical PVBS Spools................................................................................43
Electric and/or Mechanical Actuation, Asymmetrical PVBS Spools............................................................................. 46
Hydraulic and/or Mechanical Actuation Symmetrical PVBS Spools............................................................................49
Hydraulic and/or Mechanical Actuation, Asymmetrical PVBS Spools........................................................................ 51
PVG 16 Actuation
PVM Manual Actuation................................................................................................................................................................ 54
PVMD Cover................................................................................................................................................................................56
PVH Hydraulic Actuation.............................................................................................................................................................57
PVHC Electro-Hydraulic Actuation...........................................................................................................................................59
PVE Electrical Actuation...............................................................................................................................................................61
PVEO – ON/OFF Voltage Control Actuator........................................................................................................................... 63
PVEO Technical Data............................................................................................................................................................... 65
PVEA – Proportional Spool Control Actuator.......................................................................................................................66
PVEA Technical Data................................................................................................................................................................67
PVG 16 Connector Variants........................................................................................................................................................ 69
Fault Monitoring and Fault Reaction
Generic Fault Reaction................................................................................................................................................................. 70
Fault Reaction Overview..............................................................................................................................................................71
PVS End Plates
PVS/PVSI ........................................................................................................................................................................................... 73
PVS/PVSI with LX-connection....................................................................................................................................................75
PVSI with P-, T-, LX- and M-connection.................................................................................................................................. 77
PVST with T-connection...............................................................................................................................................................79
PVAS Stay Bolts
PVAS Part Numbers....................................................................................................................................................................... 82
PVG 16 modules total length and weight.............................................................................................................................82
PVG 32/16 Combinations............................................................................................................................................................ 83
PVG 256/128/32/16 Combinations..........................................................................................................................................84
PVG 16 Combinations Valve Stack Dimensions
PVG 16 Dimensions....................................................................................................................................................................... 86
PVG 32/16 Dimensions.................................................................................................................................................................87
PVG 100/16 Dimensions.............................................................................................................................................................. 89
PVG 120/16 Dimensions.............................................................................................................................................................. 91
PVG 128/16 Dimensions.............................................................................................................................................................. 93
PVG 256/16 Dimensions.............................................................................................................................................................. 95
Contents
General Information
General Description
PVG is a hydraulic, load-sensing proportional valve, designed for optimal machine performance and
maximum design flexibility. The PVG valve design is based on a modular concept that enables machine
designers to specify a valve solution suitable for multiple market segments across multiple applications.
The PVG 16 is a member of the PVG product platform.
PVG 16 controls work port flow up to 65 l/min and up to 420 bar work port pressure.
The load independent proportional control valve and high performance actuator technology combined
with a low pressure drop design improves the machine performance and efficiency – increasing
productivity and reducing energy consumption.
PVG 16 Features
PVG load-sensing proportional valves features and benefits summarized in a few bullets.
• Inlet flow up to 140 l/min [37 US gal/min] 230 l/min [61 US gal/min] when used with mid-inlet
• Easy integration with PVG 32
• Possible combination with the rest of the PVG family: PVG 100, PVG 120 or PVG 128/256 when using
an interface module
• Up to 12 basic modules per PVG 16 valve group
• Load-independent flow control:
‒ Oil flow to an individual function is independent of the load pressure of this function
‒ Oil flow to one function is independent of the load pressure of other functions
• Reliable regulation characteristics across the entire flow range
• Load sense relief valves for A and B port enables reduced energy loss at target pressure
• Several options for connection threads and flange mount
• Compact design, easy installation and serviceability
General Information
PVP PVE
PVS PVHC
PVAS
The PVG 16 PVP inlet modules, also referred to as pump side modules, act as an interface between the
PVG 16 proportional valve group and the hydraulic pump and tank reservoir.
PVP Inlet Module
The PVP inlet module variants are based on a generic platform with a selection of additional features,
enabling you to tailor the PVP to suit the demands of any hydraulic system.
Symbols
Fixed displacement pump Variable displacement pump
The generic PVP inlet module platform includes the following main variants:
• Open center PVP for fixed displacement pumps; Open Center PVP on page 8
• Open center PVP with PPRV for fixed displacement pumps, Open Center PVP with PPRV on page 10
• Open center PVP with PPRV and damped pressure adjustment spool for fixed displacement pumps;
Open center PVP with PPRV and adjustment spool on page 13
• Closed center PVP for variable displacement pumps; Closed Center PVP on page 16
• Closed center PVP with PPRV for fixed displacement pumps; Closed Center PVP with PPRV on page 18
95 [3.74] 23 [0.9]
110 [4.33] 48 [1.89]
250
3000
200
150
2000
100
1000
50
0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]
[psi] (bar)
20
240
16
12
160
80
4
0 0
0 20 40 60 80 100 120 140 (l/min)
0 4 8 12 16 20 24 28 32 36 [US gal/min]
Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
157B5200 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF 5/16-18 UNC –
P Pp
250
3000
200
150
2000
100
1000
50
0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]
[psi] (bar)
20
240
16
12
160
80
4
0 0
0 20 40 60 80 100 120 140 (l/min)
0 4 8 12 16 20 24 28 32 36 [US gal/min]
[psi] (bar)
260 20
18
220
16
180 14
12
140
10
100 8
60 6
4
20
2
0 0
0 10 20 30 40 50 (l/min)
0 2 4 6 8 10 12 [US gal/min]
Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
157B5210 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC –
157B5212 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC Yes
157B5310 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC –
157B5312 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF – 5/16-18 UNC Yes
157B5380 PVE 1 1/16 UN 1 1/16 UN 1/2-20 UNF 1/2-20 UNF 9/16-18 UNF 5/16-18 UNC –
157B5390 PVH/PVHC 1-1/16 UN 1-1/16 UN 9/16-18 UNF 9/16-18 UNF 9/16-18 UNF 5/16-18 UNC –
* For more information please see PVPX, Electrical LS Pressure Unloading Valve on page 20
All modules can be manually activated with the PVM. For more information please see PVM Manual
Actuation on page 54.
250
3000
200
150
2000
100
1000
50
0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]
[psi] (bar)
20
240
16
12
160
80
4
0 0
0 20 40 60 80 100 120 140 (l/min)
0 4 8 12 16 20 24 28 32 36 [US gal/min]
[psi] (bar)
260 20
18
220
16
180 14
12
140
10
100 8
60 6
4
20
2
0 0
0 10 20 30 40 50 (l/min)
0 2 4 6 8 10 12 [US gal/min]
Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
All modules can be manually activated with the PVM. For more information please see PVM Manual
Actuation on page 54.
250
3000
200
150
2000
100
1000
50
0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]
Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
157B5201 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF 5/16-18 UNC -
P Pp
250
3000
200
150
2000
100
1000
50
0 0 Q
0 20 40 60 80 100 120 140 [l/min]
Q
0 4 8 12 16 20 24 28 32 36 [US gal/min]
[psi] (bar)
260 20
18
220
16
180 14
12
140
10
100 8
60 6
4
20
2
0 0
0 10 20 30 40 50 (l/min)
0 2 4 6 8 10 12 [US gal/min]
All modules can be manually activated with the PVM. For more information please see PVM Manual
Actuation on page 54.
Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
157B5211 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC -
157B5213 PVE 7/8-14 UNF 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC Yes
157B5311 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC -
157B5313 PVE 1-1/16 UN 1-1/16 UN 1/2-20 UNF 1/2-20 UNF - 5/16-18 UNC Yes
157B5381 PVE 1-1/16 UN 1-1/16 UN 9/16-18 UNF 9/16-18 UNF 9/16-18 UNF 5/16-18 UNC -
157B5391 PVH/PVHC 1-1/16 UN 1-1/16 UN 9/16-18 UNF 9/16-18 UNF 9/16-18 UNF 5/16-18 UNC
* For more information please see PVPX, Electrical LS Pressure Unloading Valve on page 20
Configuration variants
Normally Open (NO) Normally Open with Manual Normally Closed (NC)
Override (NOMO)
Technical Data
Max. pressure drop @ 0.1 l/min [2.6 US gal/min] 2 bar [30 psi]
Max. coil surface temperature 155°C [311°F]
Oil temperature Recommended range 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90°C [194°F]300 ms
Ambient recommended temperature range -30 to 60°C [-22 to 140°F]
Oil viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2300/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Oil cleanliness according to ISO 4406 23/19/16
157B4257 NOMO PUSH & TURN 24 VDC 1x2 DIN 3/4-16 UNF IP65
157B4259 NOMO PUSH & TURN 24 VDC 1x2 DIN 3/4-16 UNF IP65
The PVB basic modules, also referred to as work sections, is the interface between the proportional valve
group and the work function such as a cylinder or a motor.
PVB basic module
The PVB basic module variants are based on a generic platform with a selection of additional features,
enabling you to tailor the PVB to suit the demands of any hydraulic system. The generic PVB basic
module platform includes the following main variants:
Symbols
Uncompensated PVB Compensated PVB
PVB dimensions
114 [4.49]
109 [4.29]
Compensated PVB
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The Compensated PVB features:
• Integrated LS shuttle network
• Integrated compensator
1 0 2
A
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218
70
18
65 17
60 16
AA = 5/min D
15
55 A = 10 l/min
14
B = 15 l/min
50 13 C = 25 l/min
45 12 D = 40 l/min
11
40
10
35 C
9
30 8
7
25
6
B
20 5
15 4
3
10
2 A
5 AA
1
P
0 25 50 75 100 125 150 175 200 225 250 275 300 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 [psi]
P P
[psi] (bar)
Port A/B
5
70
4,5
60
4
50 3,5
T-line
3
40
2,5
P-line
30 2
20 1,5
1
10
0,5
0 0 Q
0 25 50 75 100 125 150 (l/min)
Q
0 5 10 15 20 25 30 35 40 [US gal/min]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
1 0 2
A
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218
2500 350
300
2000
250
1500
200
150
1000
100
500
50
0 0 Q
0 20 40 60 80 100 120 140 (l/min)
Q
0 5 10 15 20 25 30 35 40 45 [US gal/min]
400 28
26
360
24
320 22
20
280 PVLP
18
240
16
200 14
12 PVLA
160
10
120 8
80 6
4
40
2
0 0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 [US gal/min]
70
18
65 17
60 16
AA = 5/min D
15
55 A = 10 l/min
14
B = 15 l/min
50 13 C = 25 l/min
45 12 D = 40 l/min
11
40
10
35 C
9
30 8
7
25
6
B
20 5
15 4
3
10
2 A
5 AA
1
P
0 25 50 75 100 125 150 175 200 225 250 275 300 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 [psi]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
1 0 2
A
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218
Q
(l/min) [US gal/min]
70
18
65 17
60 16
15
55
14
50 13
45 12
11
40
10
35 9
30 8
7
25
6
20 5
15 4
3
10
2
5
1
0 P
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 [psi]
70
18
65 17
60 16
AA = 5/min D
15
55 A = 10 l/min
14
B = 15 l/min
50 13 C = 25 l/min
45 12 D = 40 l/min
11
40
10
35 C
9
30 8
7
25
6
B
20 5
15 4
3
10
2 A
5 AA
1
P
0 25 50 75 100 125 150 175 200 225 250 275 300 (bar)
P
0 500 1000 1500 2000 2500 3000 3500 4000 [psi]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Uncompensated PVB
The uncompensated PVB is intended for controlling a work function where the function behavior in
terms of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The Uncompensated PVB features:
• Integrated LS shuttle network
• Optional load drop check valve
1 0 2
A
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218
P P
[psi] (bar)
Port A/B
5
70
4,5
60
4
50 3,5
T-line
3
40
2,5
P-line
30 2
20 1,5
1
10
0,5
0 0 Q
0 25 50 75 100 125 150 (l/min)
Q
0 5 10 15 20 25 30 35 40 [US gal/min]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Maximum rated flow A/B-port 65 l/min [17 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Ambient -30 to 60°C [-22 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
1 0 2
A
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
PVH (bar) PVH (bar)
15 13 11 9 7 5 5 7 9 11 13 15
PVH [psi] PVH [psi]
218 189 160 131 102 73 73 102 131 160 189 218
2500 350
300
2000
250
1500
200
150
1000
100
500
50
0 0 Q
0 20 40 60 80 100 120 140 (l/min)
Q
0 5 10 15 20 25 30 35 40 45 [US gal/min]
P P
[psi] (bar)
Port A/B
5
70
4,5
60
4
50 3,5
T-line
3
40
2,5
P-line
30 2
20 1,5
1
10
0,5
0 0 Q
0 25 50 75 100 125 150 (l/min)
Q
0 5 10 15 20 25 30 35 40 [US gal/min]
Technical Data
Maximum rated pressure P-port continuous 350 bar [5076 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [363/580 psi]
Maximum rated flow P-port 140 l/min [37 US gal/min]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
The pressure setting of the PVLP must always be 20 bar [290 psi] higher than LS A/B setting in the same
module.
PVLP schematic
Port pressure
P109174
2500 350
300
2000
250
1500
200
150
1000
100
500
50
0 0 Q
0 20 40 60 80 100 120 140 (l/min)
Q
0 5 10 15 20 25 30 35 40 45 [US gal/min]
Port pressure
P109175
400 28
26
360
24
320 22
20
280 PVLP
18
240
16
200 14
12 PVLA
160
10
120 8
80 6
4
40
2
0 0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 [US gal/min]
The main spools (PVBS) determines the flow out of the work section or the pressure build up.
PVBS main spool
The PVBS main spool variants are based on a generic platform with a wide selection of additional
features, enabling you to tailor the PVBS to suit the demands of any hydraulic system and any function.
The PVBS main spool can be activated in three different ways:
• Mechanically by a PVM lever
• Electrically by a PVE/PVHC actuator
• Hydraulically by a PVH actuator
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM (mm) PVM (mm)
10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5
PVM [in] PVM [in]
0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39
Us Us
PVEA PVEA UDC
UDC
0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75
260
3600
240
3200 220
200
2800
180
2400
160
Pressure drop for
2000 140 PVBS 65 l/min
120
1600
100
1200 80
800 60
40
400
20
0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [US gal/min]
260
3600
240
3200 220
200
2800
180
2400
160
Pressure drop for
2000 140 PVBS 65 l/min
120
1600
100
1200 80
800 60
40
400
20
0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [US gal/min]
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM PVM
(mm) 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 (mm)
PVM PVM
[in] 0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39 [in]
PVEH PVEH
PVEH-U 0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75 PVEH-U
260
3600
240
3200 220
200
2800
180
2400
160
Pressure drop for
2000 140 PVBS 65 l/min
120
1600
100
1200 80
800 60
40
400
20
0 Q
0 5 10 15 20 25 30 35 40 45 50 55 60 [l/min]
Q
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [US gal/min]
PVG 16 Actuation
PVG 16 Actuation
183.8 [7.24]
85 [3.35]
Technical data
Spool displacement Torque
From neutral position PVM+PVMD
2.2 ± 0.2 N•m [5.0 ± 1.8 lb•in]
PVM+PVE
PVM+PVH 2.7 ± 0.2 N•m [23.9 ± 1.8 lb•in]
Max. spool travel PVM+PVMD
2.8 ± 0.2 N•m [6.3 ± 1.8 lb•in]
PVM+PVE
PVM+PVH 7.1 ± 0.2 N•m [62.8 ± 1.8 lb•in]
Standard control range 13.9°
Control lever range + float position 22.3°
11107505 — — —
11107506 Yes — —
11107507 — Yes —
PVG 16 Actuation
PVMD Cover
The PVMD cover is used when work section is purely mechanical activated.
PVMD Cover
Dimensions, mm [in]
39 [1.54]
86 [3.39]
14 [0.55]
PVG 16 Actuation
C Caution
27 [1.06]
29 [1.14]
39 [1.55] 28 [1.1]
PVG 16 Actuation
75 20 1
19 Spool types:
D
70 6
18 AA = 5/min
65 17 A = 10 l/min
60 16 B = 15 l/min
1
15 C = 25 l/min C
55 6
14 D = 40 l/min
50 13 1 = First PVB after PVP
45 12 6 = Sixth PVB after PVP
11
40
10 B
35 9
30 8
7
25
6
20 5
15 4 A
3
10 AA
2
5
1
PVM PVM
(mm) 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 (mm)
PVM PVM
[in] 0.39 0.35 0.31 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0 0 0.04 0.08 0.12 0.16 0.20 0.24 0.28 0.31 0.35 0.39 [in]
PVEH PVEH
PVEH-U 0.75 0.7 0.65 0.6 0.55 0.5 0.5 0.55 0.6 0.65 0.7 0.75 PVEH-U
Technical data
Main spool spring control pressure range 5 – 15 bar [73 – 218 psi]
PVG 16 Actuation
C Caution
Inlet with Hydraulic Pilot Pressure is needed.
PVHC, Electro-Hydraulic Actuator
PVHC schematic
PVHC dimensions
92 [3.62]
PVG 16 Actuation
P A Spool stroke, mm P B
10
7 Ideal curve
6
4 Hysteresis
3
P109250
The hysteresis is affected by viscosity, friction, flow forces, dither frequency and modulation frequency.
Dither frequency with a certain amplitude is needed for optimal application performance.
Technical data
Main spool spring control pressure range 5-15 bar [73-218 psi]
Protection class IP 67
PVG 16 Actuation
PVG 16 Actuation
PVG 16 Actuation
A
B Pp
DI_B
DI_A
LED Circuit /
LED Microcontroller
Udc Power
Supply
SV1 SV2
Ramp Ramp
PVEO-DI LVDT
1 0 2
P109126
An energization of solenoid valve SV1 and a simultaneous de-energization of SV2 will cause the main
spool to move to the right direction and vice versa. If both SV1 and SV2 are energized or de-energized
simultaneously, the main spool stays locked in its neutral position.
PVG 16 Actuation
PVG 16 Actuation
Control specifications
Description Type 12 VDC ± 10% 24 VDC ± 10%
Supply Voltage (UDC) Rated/range 11 to 15 VDC 12 to 30 VDC
Max. ripple 5% 5%
Current Consumption Typical 320 mA 160 mA
Technical data
Pilot pressure Nominal 13.5 bar [196 psi]
Minimum 10.0 bar [145 psi]
Maximum 15.0 bar [218 psi]
Fluid consumption Neutral 0.04 l/min [0.01 US gal/min]
Locked position 0.04 l/min [0.01 US gal/min]
Actuating 0.6 l/min [0.16 US gal/min]
Fluid temperature Ambient Storage -50 to +90°C [-58 to +194°F]
Ambient Operating -40 to +90°C [-40 to +194°F]
Fluid viscosity Operating range 12 to 75 mm2/sec [65 to 347 SUS]
Minimum 4 mm2/sec [39 SUS]
Maximum 460 mm2/sec [2128 SUS]
Fluid cleanliness Minimum 18/16/13 (according to ISO 4406)
LED characteristic
Color LED characteristic Description
Green Power ON
PVG 16 Actuation
The PVEA functionality includes an electric circuit with a closed-loop logic. An integrated feedback
transducer measures spool movement in relation to the input signal. The PVEA features passive fault
monitoring, LED indicating fault state, error output pin and Power Save mode.
PVEA functionality
Power Save mode is entered when the command signal to the PVEA is below 15% of the supply voltage.
Entering Power Save mode will torn off the power to the solenoid valves. Power Save mode can be
identified by the LED blinking green at 1 Hz.
All variants available with following features:
• Neutral position or max. spool stroke according to control signal
• 11–32 VDC supply multi-voltage
• DEUTSCH connectors
• Standard PVE pilot oil pressure of 13.5 bar
• LED indicating error state and passive fault monitoring
• Float (-F) and CAN-interface (-CI)
PVG 16 Actuation
Control specification
Description Type Value
Supply voltage (UDC) Rated/range 11 to 32 VDC
Max. ripple 15 bar [218 psi]
Signal voltage (US) Neutral 0.5 UDC
Q: P -> A 0.25 UDC
Q: P -> B 0.75 UDC
Current consumption @ 12 VDC 320 mA
@ 24 VDC 170 mA
Input impedance Rated 12 kΩ
Input capacitance Rated 100 µF
Technical data
Pilot pressure Nominal 13.5 bar [196 psi]
Minimum 10.0 bar [145 psi]
Maximum 15.0 bar [218 psi]
PVG 16 Actuation
LED characteristic
Color LED characteristic Description
Green constant Actuating
PVG 16 Actuation
3 4
2 3
2 3 1 4
2 5
1 6
1 4
2 3
1 4
Control Signal Monitoring The Control signal voltage (US) is continuously monitored.
The permissible range is between 15% and 85% of the supply voltage (UDC).
Outside this range the PVE will switch into an error state. A disconnected US
pin (floating) is recognized as a neutral set point.
Transducer/LVDT Supervision The internal LVDT wires are monitored. If the signals are interrupted or short-
circuited, the PVE will switch into an error state.
Supervision of Spool Position The actual position must always correspond to the demanded position (US).
If the actual spool position is further out from neutral than the demanded
spool position or in opposite direction, the PVE will switch into an error state.
Spool position closer to neutral and in same direction will not cause an error
state – the situation is considered in control.
Float Position Monitoring Float position must be entered or left within a time limit.
A too high delay on the 1x6 pin float PVE will cause an error state – this is
relevant for the 1x6 pin PVEH-F actuators only.
Temperature Monitoring When the temperature is too high the PVE LED will light constant red and
solenoid valves will be disabled.
Description Monitoring LED Solenoid valves Error pin output Reaction time
(ms)
Spool not at setpoint Passive — High 250
Unable to reach float position Passive — High 250
UDC > max. Passive Disabled — 250
UDC < min. Passive ——————— Disabled — 250
US out of range Passive — High 250
LVDT error Passive — High 250
Temp > max. Passive Disabled High 250
The PVG 16 PVS/PVSI end plates close off the valve stack section placed between them by placing them
at the end. Furthermore, the end plate is ensuring Load Sense (LS) is relieved to tank pressure when the
valve is not operated.
The PVS/PVSI end plate variants are based on a generic platform with a wide selection of additional
features, enabling you to tailor the PVS/PVSI to suit the demands of any hydraulic system.
The generic PVS end plates platform includes the following main variants:
• PVS/PVSI – Either aluminum or cast iron
• PVS/PVSI with LX-connection – Either aluminum or cast iron
• PVSI with P-, T-, LX- and M-connection – Cast iron
• PVST with T-connection – Steel
PVSI with P-, T-, LX- and M-connection PVST with T-connection
PVS/PVSI on page 73
PVS/PVSI with LX-connection on page 75
PVSI with P-, T-, LX- and M-connection on page 77
PVST with T-connection on page 79
PVS/PVSI
The PVS/PVSI made of either aluminum or cast iron works as an end plate.
PVS/PVSI
PVS/PVSI schematic
PVS/PVSI dimensions
109.4 [4.31]
95 [3.74]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
Lx
LX
G1/8
38.4 [1.51]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
40 [1.57]
20.4 [0.8]
95 [3.74]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Technical data
Maximum rated pressure A/B-port continuous 380 bar [5510 psi]
A/B-port intermittent 420 bar [6090 psi]
Fluid temperature Recommended 30 to 60°C [86 to 140°F]
Minimum -30°C [-22°F]
Maximum 90° [194°F]
Ambient temperature Recommended -30 to 60°C [-22 to 140°F]
Fluid viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS]
Fluid cleanliness Minimum 23/19/16 (according to ISO 4406)
When using a PVST (157B2500 or 157B2520) it is not possible to use the LS A/B fitting in the bottom of
the PVG section next to the PVST.
PVAS Stay Bolts kit for various PVG combinations consist of three tie rods, six washers, six nuts and O-ring.
Use the guide and reference tables how to choose PVAS kit.
The tie rods are inserted through the entire length of the PVG valve stack. The nuts are tightened at the
pump side and at the end plate.
To find the PVAS kit that fits your PVG 16 valve stack, you need to go to the table PVG 16 modules total
length and weight on page 82 and find the length. Then go to the table PVAS Part Numbers on page 82
and find the matching part number.
For stay bolts for a PVG 32/16 combination, see this PVG 32/16 Combinations on page 83.
Stay bolts for PVG 256/128/32/16 combinations consist of two different kits. See PVG 256/128/32/16
Combinations on page 84 to find the right kits for your combination.
Combinations with PVG 100 and PVG 120 requires special PVAS kits. These are not included in the PVAS
table.
No. of 1 2 3 4 5 6 7 8 9 10 11 12
PVB 16
Length 140 189 213 262 311 336 385 434 458 507 551 576
mm [in] [5.51] [7.44] [8.39] [10.31] [12.24] [13.23] [15.16] [17.09] [18.03] [19.96] [21.69] [22.68]
Weight* 7,2 10,9 14,6 18,3 22 25,7 29,4 33,1 36,8 40,5 44,2 47,9
kg [lb] [15.9] [24] [32.2] [40.3] [48.5] [56.7] [64.8] [73] [81.1] [89.3] [97.4] [105.6]
* Weight is for a PVG 16 with a PVE on each working section and is only approximate.
PVB 16
Modules 1 2 3 4 5 6 7 8 9 10 11
mm [in]
1 189 238 262 311 360 409 434 483 507 551 600
[7.44] [9.37] [10.31] [12.24] [14.17] [16.10] [17.09] [19.02] [19.96] [21.69] [23.62]
2 238 287 311 360 409 434 483 507 551 600 646
[9.37] [11.30] [12.24] [14.17] [16.10] [17.09] [19.02] [19.96] [21.69] [23.62] [25.43]
3 287 336 360 409 458 483 527 576 600 646 -
[11.30] [13.23] [14.17] [16.10] [18.03] [19.02] [20.75] [22.68] [23.62] [25.43]
4 336 385 409 458 483 527 576 622 646 - -
[13.23] [15.16] [16.10] [18.03] [19.02] [20.75] [22.68] [24.49] [25.43]
5 385 434 458 507 551 576 622 670 - - -
[15.16] [17.09] [18.03] [19.96] [21.69] [22.68] [24.49] [26.38]
PVB 6 434 483 507 551 600 622 670 - - - -
32 [17.09] [19.02] [19.96] [21.69] [23.62] [24.49]
7 483 527 551 600 646 - - - - - -
[19.02] [20.75] [21.69] [23.62] [25.43]
8 527 576 600 646 - - - - - - -
[20.75] [22.68] [23.62] [25.43]
9 576 622 646 - - - - - - - -
[22.68] [24.49] [25.43]
10 622 670 - - - - - - - - -
[24.49] [26.38]
11 670 - - - - - - - - - -
[26.38]
O-rings are a part of the PVAS kits – no additional part number needed.
C Caution
Example
For 2 PVB 256 and 1 PVB 128 and 1 PVB 32 and 2 PVB 16: PVAS 1 Part number = 11187681 from Table 1.
PVAS 2 = 278 mm from Table 1 + 152 mm from Table 2= 278+152 =430 mm which equals 157B8027 in
the PVAS table.
PVG 16 Dimensions
The table of PVB 16 valve stack dimensions overview table with accompanying drawing.
22.5°
191.3 [7.53]
121.6 [4.79]
95 [3.74]
78.5 [3.09] 110 [4.33] 60 [2.36]
261.5 [10.3]
303.8 [11.96]
L1
L2
73.5 [2.89]
62.5 [2.46]
25 [0.98]
18.5 [0.73]
38.5 [1.52]
71.5 [2.81]
91 [3.58]
L1
L2
95 [3.74]
1 L1 122 162 202 242 282 322 362 402 442 482 522
[4.80] [6.38] [7.95] [9.53] [11.10] [12.68] [14.25] [15.83] [17.40] [18.98] [20.55]
L2 189 238 262 311 360 385 434 483 507 551 600
[7.44] [9.37] [10.31] [12.24] [14.17] [15.16] [17.09] [19.02] [19.96] [21.69] [23.62]
2 L1 170 210 250 290 330 370 410 450 490 530 570
[6.69] [8.27] [9.84] [11.42] [12.99] [14.57] [16.14] [17.72] [19.29] [20.87] [22.44]
L2 238 287 311 360 409 434 483 507 551 600 646
[9.37] [11.30] [12.24] [14.17] [16.10] [17.09] [19.02] [19.96] [21.69] [23.62] [25.43]
3 L1 218 258 298 338 378 418 458 498 538 578 -
[8.58] [10.16] [11.73] [13.31] [14.88] [16.46] [18.03] [19.61] [21.18] [22.76]
L2 287 336 360 409 458 483 527 576 600 646 -
[11.30] [13.23] [14.17] [16.10] [18.03] [19.02] [20.75] [22.68] [23.62] [25.43]
4 L1 266 306 346 386 426 466 506 546 586 - -
[10.47] [12.05] [13.62] [15.20] [16.77] [18.35] [19.92] [21.50] [23.07]
L2 336 385 409 458 483 527 576 622 646 - -
[13.23] [15.16] [16.10] [18.03] [19.02] [20.75] [22.68] [24.49] [25.43]
5 L1 314 354 394 434 474 514 554 594 - - -
[12.36] [13.94] [15.51] [17.09] [18.66] [20.24] [21.81] [23.39]
L2 385 434 458 507 551 576 622 670 - - -
[15.16] [17.09] [18.03] [19.96] [21.69] [22.68] [24.49] [26.38]
6 L1 362 402 442 482 522 562 602 - - - -
[14.25] [15.83] [17.40] [18.98] [20.55] [22.13] [23.70]
L2 434 483 507 551 600 622 670 - - - -
[17.09] [19.02] [19.96] [21.69] [23.62] [24.49] [26.38]
7 L1 410 450 490 530 570 610 - - - - -
[16.14] [17.72] [19.29] [20.87] [22.44] [24.02]
L2 483 527 551 600 646 670 - - - - -
[19.02] [20.75] [21.69] [23.62] [25.43] [26.38]
8 L1 458 498 538 578 - - - - - - -
[18.03] [19.61] [21.18] [22.76]
L2 527 576 600 646 - - - - - - -
[20.75] [22.68] [23.62] [25.43]
L3
L1
L2
1 L1 172 212 252 292 332 372 412 452 492 532 572
[6.77] [8.35] [9.92] [11.50] [13.07] [14.65] [16.22] [17.80] [19.37] [20.94] [22.52]
L2 236 285 311 358 407 432 481 530 554 603 652
[9.29] [11.22] [12.24] [14.09] [16.02] [17.01] [18.94] [20.87] [21.81] [23.74] [25.67]
L3 80 [3.15]
2 L1 220 260 300 340 380 420 460 500 540 580 620
[8.66] [10.24] [11.81] [13.39] [14.96] [16.54] [18.11] [19.69] [21.26] [22.83] [24.41]
L2 284 333 359 406 455 480 529 578 602 651 700
[11.18] [13.11] [14.13] [15.98] [17.91] [18.90] [20.83] [22.76] [23.70] [25.63] [27.56]
L3 128 [5.04]
3 L1 268 308 348 388 428 468 508 548 588 628 668
[10.55] [12.13] [13.70] [15.28] [16.85] [18.43] [20.00] [21.57] [23.15] [24.72] [26.30]
L2 332 381 407 454 503 528 577 626 650 699 748
[13.07] [15.00] [16.02] [17.87] [19.80] [20.79] [22.72] [24.65] [25.59] [27.52] [29.45]
L3 176 [6.93]
4 L1 316 256 396 436 476 516 556 596 636 676 716
[12.44] [10.08] [15.59] [17.17] [18.74] [20.31] [21.89] [23.46] [25.04] [26.61] [28.19]
L2 380 429 455 502 551 576 625 674 698 747 796
[14.96] [16.89] [17.91] [19.76] [21.69] [22.68] [24.61] [26.54] [27.48] [29.41] [31.34]
L3 224 [8.82]
5 L1 364 404 444 484 524 564 604 644 684 724 -
[14.33] [15.91] [17.48] [19.06] [20.63] [22.20] [23.78] [25.35] [26.93] [28.50]
L2 428 477 503 550 599 624 673 722 746 795 -
[16.85] [18.78] [19.80] [21.65] [23.58] [24.57] [26.50] [28.43] [29.37] [31.30]
L3 272 [10.71]
6 L1 412 452 492 532 572 612 652 692 732 - -
[16.22] [17.80] [19.37] [20.94] [22.52] [24.09] [25.67] [27.24] [28.82]
L2 476 525 551 598 647 672 721 770 794 - -
[18.74] [20.67] [21.69] [23.54] [25.47] [26.46] [28.39] [30.31] [31.26]
L3 320 [12.60]
7 L1 460 500 540 580 620 660 700 740 - - -
[18.11] [19.69] [21.26] [22.83] [24.41] [25.98] [27.56] [29.13]
L2 524 573 599 646 695 720 769 818 - - -
[20.63] [22.56] [23.58] [25.43] [27.36] [28.35] [30.28] [32.20]
L3 368 [14.49]
8 L1 508 548 588 628 668 708 748 - - - -
[20.00] [21.57] [23.15] [24.72] [26.30] [27.87] [29.45]
L2 572 621 647 694 743 768 817 - - - -
[22.52] [24.45] [25.47] [27.32] [29.25] [30.24] [32.17]
L3 416 [16.38]
L3
L1
L2
1 L1 284 324 364 404 444 484 524 564 604 644 684
[11.18] [12.76] [14.33] [15.91] [17.48] [19.06] [20.63] [22.20] [23.78] [25.35] [26.93]
L2 348 397 421 470 519 544 593 642 666 715 759
[13.70] [15.63] [16.57] [18.50] [20.43] [21.42] [23.35] [25.28] [26.22] [28.15] [29.88]
L3 80 [3.15]
2 L1 351 391 431 471 511 551 591 631 671 711 751
[13.82] [15.39] [16.97] [18.54] [20.12] [21.69] [23.27] [24.84] [26.42] [27.99] [29.57]
L2 413 462 486 535 584 609 658 707 731 780 824
[16.26] [18.19] [19.13] [21.06] [22.99] [23.98] [25.91] [27.83] [28.78] [30.71] [32.44]
L3 128 [5.04]
3 L1 418 458 498 538 578 618 658 698 738 778 818
[16.46] [18.03] [19.61] [21.18] [22.76] [24.33] [25.91] [27.48] [29.06] [30.63] [32.20]
L2 478 527 551 600 649 674 723 772 796 845 889
[18.82] [20.75] [21.69] [23.62] [25.55] [26.54] [28.46] [30.39] [31.34] [33.27] [35.00]
L3 176 [6.93]
4 L1 485 525 565 605 545 685 725 765 805 845 885
[19.09] [20.67] [22.24] [23.82] [21.46] [26.97] [28.54] [30.12] [31.69] [33.27] [34.84]
L2 543 592 616 665 714 739 788 837 861 910 954
[21.38] [23.31] [24.25] [26.18] [28.11] [29.09] [31.02] [32.95] [33.9] [35.83] [37.56]
L3 224 [8.82]
5 L1 552 592 632 672 712 752 792 832 872 912 -
[21.73] [23.31] [24.8] [26.46] [28.03] [29.61] [31.18] [32.76] [34.33] [35.91]
L2 608 657 681 730 779 804 853 902 926 975 -
[23.94] [25.87] [26.81] [28.74] [30.67] [31.65] [33.58] [35.51] [36.46] [38.39]
L3 272 [10.71]
6 L1 619 659 699 739 779 819 859 899 939 - -
[24.37] [25.94] [27.52] [29.09] [30.67] [32.24] [33.82] [35.39] [36.97]
L2 673 722 746 795 844 869 918 967 991 - -
[26.50] [28.43] [29.37] [31.30] [33.23] [34.21] [36.14] [38.07] [39.02]
L3 320 [12.60]
7 L1 686 726 766 806 846 886 926 966 - - -
[27.01] [28.58] [30.16] [31.73] [33.31] [34.88] [36.46] [38.03]
L2 738 787 811 860 909 934 983 1032 - - -
[29.06] [30.98] [31.93] [33.86] [35.79] [36.77] [38.70] [40.63]
L3 368 [14.49]
8 L1 753 793 833 873 913 953 993 - - - -
[29.65] [31.22] [32.80] [34.37] [35.94] [37.52] [39.09]
L2 803 852 876 925 974 999 1048 - - - -
[31.61] [33.54] [34.49] [36.42] [38.35] [39.33] [41.26]
L3 639 [25.16]
There is a horizontal difference 62.5 mm [2.46 in] in the mounting plane of the PVG 120/PVG 16.
L1
L2
L3
132 [5.20]
L1
L2
L3
132 [5.20]
T
M LS
M
B
T
M LS
Comatrol
www.comatrol.com Local address:
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss
Power Solutions Trading
Danfoss Danfoss Danfoss (Shanghai) Co., Ltd.
Power Solutions (US) Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.