Sensor & Iot - Unit 2
Sensor & Iot - Unit 2
UNIT: 2
Sensors in manufacturing are basically employed to automatically carry out the
production operations as well as process monitoring activities. Sensor technology has
the following important advantages in transforming a conventional manufacturing unit
into a modern one.
1. Sensors alarm the system operators about the failure of any of the
sub units of manufacturing system. It helps operators to reduce the
downtime of complete manufacturing system by carrying out the
preventative measures.
2. Reduces requirement of skilled and experienced labors.
3. Ultra-precision in product quality can be achieved.
Sensor
It is defined as an element which produces signal relating to the quantity being
measured. According to the Instrument Society of America, sensor can be defined as
“A device which provides a usable output in response to a specified measurand.” Here,
the output is usually an ‘electrical quantity’ and measurand is a ‘physical quantity,
property or condition which is to be measured’. Thus in the case of, say, a variable
inductance displacement element, the quantity being measured is displacement and the
sensor transforms an input of displacement into a change in inductance.
Transducer
It is defined as an element when subjected to some physical change experiences a
related change or an element which converts a specified measurand into a usable output
by using a transduction principle.
It can also be defined as a device that converts a signal from one form of energy to
another form.
Sensor/transducers specifications
Sensor specifications inform the user to the about deviations from the ideal behaviour
of the sensors. Following are the various specifications of a sensor/transducer system.
1. Range
The range of a sensor indicates the limits between which the input can vary. For
example, a thermocouple for the measurement of temperature might have a range of
25-225 °C.
2. Span
The span is difference between the maximum and minimum values of the input. Thus,
the above-mentioned thermocouple will have a span of 200 °C.
3. Error
Error is the difference between the result of the measurement and the true value of the
quantity being measured. A sensor might give a displacement reading of 29.8 mm, when
the actual displacement had been 30 mm, then the error is –0.2 mm.
4. Accuracy
The accuracy defines the closeness of the agreement between the actual measurement
result and a true value of the measurand. It is often expressed as a percentage of the full
range output or full–scale deflection. A piezoelectric transducer used to evaluate
dynamic pressure phenomena associated with explosions, pulsations, or dynamic
pressure conditions in motors, rocket engines, compressors, and other pressurized
devices is capable to detect pressures between 0.1 and 10,000 psig (0.7 KPa to 70 MPa).
If it is specified with the accuracy of about ±1% full scale, then the reading given can
be expected to be within ± 0.7 MPa.
5. Sensitivity
Sensitivity of a sensor is defined as the ratio of change in output value of a sensor to the
per unit change in input value that causes the output change. For example, a general
purpose thermocouple may have a sensitivity of 41 µV/°C.
6. Nonlinearity
7. Hysteresis
8. Resolution
Resolution is the smallest detectable incremental change of input parameter that can be
detected in the output signal. Resolution can be expressed either as a proportion of the
full-scale reading or in absolute terms. For example, if a LVDT sensor measures a
displacement up to 20 mm and it provides an output as a number between 1 and 100
then the resolution of the sensor device is 0.2 mm.
9. Stability
Stability is the ability of a sensor device to give same output when used to measure a
constant input over a period of time. The term ‘drift’ is used to indicate the change in
output that occurs over a period of time. It is expressed as the percentage of full range
output.
10. Dead band/time
The dead band or dead space of a transducer is the range of input values for which there
is no output. The dead time of a sensor device is the time duration from the application
of an input until the output begins to respond or change.
11. Repeatability
It specifies the ability of a sensor to give same output for repeated applications of same
input value. It is usually expressed as a percentage of the full range output:
Classification of sensors
Sensors can be classified into various groups according to the factors such as
measurand, application fields, conversion principle, energy domain of the measurand
and thermodynamic considerations.
C. Force
• Strain gauge load cell
D. Fluid pressure
• Diaphragm pressure gauge
• Capsules, bellows, pressure tubes
• Piezoelectric sensors
• Tactile sensor
E. Liquid flow
• Orifice plate
• Turbine meter
F. Liquid level
• Floats
• Differential pressure
G. Temperature
• Bimetallic strips
• Resistance temperature detectors
• Thermistors
• Thermo-diodes and transistors
• Thermocouples
• Light sensors
• Photo diodes
• Photo resistors
• Photo transistor
Proximity sensors are a type of position sensor and are used to trace when an object has
moved with in particular critical distance of a transducer. Displacement sensors
1. Potentiometer Sensors
Figure 2.2.1 shows the construction of a rotary type potentiometer sensor employed to
measure the linear displacement. The potentiometer can be of linear or angular type. It
works on the principle of conversion of mechanical displacement into an electrical
signal. The sensor has a resistive element and a sliding contact (wiper). The slider
moves along this conductive body, acting as a movable electric contact.
During the sensing operation, a voltage Vs is applied across the resistive element. A
voltage divider circuit is formed when slider comes into contact with the wire. The
output voltage (VA) is measured as shown in the figure 2.2.2. The output voltage is
proportional to the displacement of the slider over the wire. Then the output parameter
displacement is calibrated against the output voltage VA.
VA = VS LA / (LA + LB)
Applications of potentiometer
These sensors are primarily used in the control systems with a feedback loop to ensure
that the moving member or component reaches its commanded position.
2. Strain Gauges
The strain in an element is a ratio of change in length in the direction of applied load to
the original length of an element. The strain changes the resistance R of the element.
Therefore, we can say,
∆R/R ∝ ε;
∆R/R = G ε (2.2.5)
where G is the constant of proportionality and is called as gauge factor. In general, the
value of G is considered in between 2 to 4 and the resistances are taken of the order of
100 Ω.
Resistance strain gauge follows the principle of change in resistance as per the equation
2.2.5. It comprises of a pattern of resistive foil arranged as shown in Figure 2.2.3. These
foils are made of Constantan alloy (copper-nickel 55-45% alloy) and are bonded to a
backing material plastic (polyimide), epoxy or glass fibre reinforced epoxy. The strain
gauges are secured to the workpiece by using epoxy or Cyanoacrylate cement Eastman
910 SL. As the workpiece undergoes change in its shape due to external loading, the
resistance of strain gauge element changes. This change in resistance can be detected
by a using a Wheatstone’s resistance bridge as shown in Figure 2.2.4. In the balanced
bridge we can have a relation,
R2/ R1 = Rx / R3
Strain gauges are widely used in experimental stress analysis and diagnosis on machines
and failure analysis. They are basically used for multi-axial stress fatigue testing, proof
testing, residual stress and vibration measurement, torque measurement, bending and
deflection measurement, compression and tension measurement and strain
measurement.
Strain gauges are primarily used as sensors for machine tools and safety in auto motives.
In particular, they are employed for force measurement in machine tools, hydraulic or
pneumatic press and as impact sensors in aerospace vehicles.
Capacitive sensor is of non-contact type sensor and is primarily used to measure the
linear displacements from few millimetres to hundreds of millimetres. It comprises of
three plates, with the upper pair forming one capacitor and the lower pair another. The
linear displacement might take in two forms:
a. One of the plates is moved by the displacement so that the plate separation
changes
b. Area of overlap changes due to the displacement.
Figure 2.2.5 shows the schematic of three-plate capacitive element sensor and
displacement measurement of a mechanical element connected to the plate 2.
Figure 2.2.5 Displacement measurement using capacitive element sensor
C = εr εo A / d
Where εr is the relative permittivity of the dielectric between the plates, εo permittivity
of free space, A is the area of overlap between two plates and d the plate separation.
As the central plate moves near to top plate or bottom one due to the movement of the
element/workpiece of which displacement is to be measured, separation in between the
plate changes. This can be given as,
C1 = (εr εo A) / (d + x) (2.2.8)
C2 = (εr εo A) / (d – x) (2.2.9)
When C1 and C2 are connected to a Wheatstone’s bridge, then the resulting out of
balance voltage would be in proportional to displacement x.
Capacitive elements can also be used as proximity sensor. The approach of the object
towards the sensor plate is used for induction of change in plate separation. This
changes the capacitance which is used to detect the object.
Applications of capacitive element sensors
Eddy current proximity sensors are used to detect non-magnetic but conductive
materials. They comprise of a coil, an oscillator, a detector and a triggering circuit.
Figure 2.3.1 shows the construction of eddy current proximity switch. When an
alternating current is passed thru this coil, an alternative magnetic field is generated.
If a metal object comes in the close proximity of the coil, then eddy currents are
induced in the object due to the magnetic field. These eddy currents create their own
magnetic field which distorts the magnetic field responsible for their generation. As
a result, impedance of the coil changes and so the amplitude of alternating current.
This can be used to trigger a switch at some pre-determined level of change in
current.
Eddy current sensors are relatively inexpensive, available in small in size, highly
reliable and have high sensitivity for small displacements.
Inductive proximity switches are basically used for detection of metallic objects.
Figure 2.3.2 shows the construction of inductive proximity switch. An inductive
proximity sensor has four components; the coil, oscillator, detection circuit and
output circuit. An alternating current is supplied to the coil which generates a
magnetic field. When, a metal object comes closer to the end of the coil, inductance
of the coil changes. This is continuously monitored by a circuit which triggers a
switch when a pre-set value of inductance change is occurred.
4. Pneumatic Sensors
5. Proximity Switches
Photo emitting devices such as Light emitting diodes (LEDs) and photosensitive
devices such as photo diodes and photo transistors are used in combination to work
as proximity sensing devices. Figure 2.3.7 shows two typical arrangements of LEDs
and photo diodes to detect the objects breaking the beam and reflecting light.
6. Hall-effect sensor
The typical application of Hall Effect sensor is the measurement of fluid level in a
container. The container comprises of a float with a permanent magnet attached at
its top. An electric circuit with a current carrying disc is mounted in the casing.
When the fluid level increases, the magnet will come close to the disc and a potential
difference generates. This voltage triggers a switch to stop the fluid to come inside
the container.
These sensors are used for the measurement of displacement and the detection of
position of an object. Hall Effect sensors need necessary signal conditioning
circuitry. They can be operated at 100 kHz. Their non-contact nature of operation,
good immunity to environment contaminants and ability to sustain in severe
conditions make them quite popular in industrial automation.
1. Tachogenerator
2. Pyroelectric sensors
These sensors work on the principle of pyroelectricity, which states that a crystal
material such as Lithium tantalite generates charge in response to heat flow. In presence
of an electric field, when such a crystal material heats up, its electrical dipoles line up
as shown in figure 2.4.3. This is called as polarization. On cooling, the material retains
its polarization. In absence of electric field, when this polarized material is subjected to
infrared irradiation, its polarization reduces. This phenomenon is the measure of
detection of movement of an object.
Figure 2.4.4 Construction and working a Pyroelectric sensor
Pyroelectric sensor comprises of a thick element of polarized material coated with thin
film electrodes on opposite faces as shown in figure 2.4.4. Initially the electrodes are in
electrical equilibrium with the polarized material. On incident of infra-red, the material
heats up and reduces its polarization. This leads to charge imbalance at the interface of
crystal and electrodes. To balance this disequilibrium, measurement circuit supplies the
charge, which is calibrated against the detection of an object or its movement.
Figure 2.4.5 shows a strain gauge load cell. It comprises of cylindrical tube to which
strain gauges are attached. A load applied on the top collar of the cylinder compress the
strain gauge element which changes its electrical resistance. Generally strain gauges are
used to measure forces up to 10 MN. The non-linearity and repeatability errors of this
transducer are ±0.03% and ±0.02% respectively.
4. Fluid pressure
Chemical, petroleum, power industry often need to monitor fluid pressure. Various
types of instruments such as diaphragms, capsules, and bellows are used to monitor the
fluid pressure. Specially designed strain gauges doped in diaphragms are generally used
to measure the inlet manifold pressure in applications such as automobiles. A typical
arrangement of strain gauges on a diaphragm is shown in figure 2.4.6. Application of
pressurized fluid displaces the diaphragm. This displacement is measured by the stain
gauges in terms of radial and/or lateral strains. These strain gauges are connected to
form the arms of a Wheatstone bridge.
In general, tactile sensors are used to sense the contact of fingertips of a robot with an
object. They are also used in manufacturing of ‘touch display’ screens of visual display
units (VDUs) of CNC machine tools. Figure 2.4.9 shows the construction of piezo-
electric polyvinylidene fluoride (PVDF) based tactile sensor. It has two PVDF layers
separated by a soft film which transmits the vibrations. An alternating current is applied
to lower PVDF layer which generates vibrations due to reverse piezoelectric effect.
These vibrations are transmitted to the upper PVDF layer via soft film. These vibrations
cause alternating voltage across the upper PVDF layer. When some pressure is applied
on the upper PVDF layer the vibrations gets affected and the output voltage changes.
This triggers a switch or an action in robots or touch displays.
6. Piezoelectric sensor
7. Liquid flow
Liquid flow is generally measured by applying the Bernoulli’s principle of fluid flow
through a constriction. The quantity of fluid flow is computed by using the pressure
drop measured. The fluid flow volume is proportional to square root of pressure
difference at the two ends of the constriction. There are various types of fluid flow
measurement devices being used in manufacturing automation such as Orifice plate,
Turbine meter etc.
7. a. Orifice plate:
Figure 2.4.11 shows a schematic of Orifice plate device. It has a disc with a hole at its
centre, through which the fluid flows. The pressure difference is measured between a
point equal to the diameter of the tube upstream and a point equal to the half the
diameter downstream. Orifice plate is inexpensive and simple in construction with no
moving parts. It exhibits nonlinear behaviour and does not work with slurries. It has
accuracy of ± 1.5%.
7. b. Turbine meter
Turbine flow meter has an accuracy of ±0.3%. It has a multi blade rotor mounted
centrally in the pipe along which the flow is to be measured. Figure 2.4.12 shows the
typical arrangement of the rotor and a magnetic pick up coil. The fluid flow rotates the
rotor. Accordingly the magnetic pick up coil counts the number of magnetic pulses
generated due to the distortion of magnetic field by the rotor blades. The angular
velocity is proportional to the number of pulses and fluid flow is proportional to angular
velocity.
8. Fluid level
The level of liquid in a vessel or container can be measured,
a. Directly by monitoring the position of liquid surface
b. Indirectly by measuring some variable related to the height.
Direct measurements involve the use of floats however the indirect methods employ
load cells. Potentiometers or LVDT sensors can be used along with the floats to measure
the height of fluid column. Force sensed by the load cells is proportional to the height
of fluid column.
Bimetallic strips are used as thermal switch in controlling the temperature or heat in a
manufacturing process or system. It contains two different metal strips bonded together.
The metals have different coefficients of expansion. On heating the strips bend into
curved strips with the metal with higher coefficient of expansion on the outside of the
curve. Figure 2.5.1 shows a typical arrangement of a bimetallic strip used with a setting-
up magnet. As the strips bend, the soft iron comes in closer proximity of the small
magnet and further touches. Then the electric circuit completes and generates an alarm.
In this way bimetallic strips help to protect the desired application from heating above
the pre-set value of temperature.
Rt = R0 (1 + αT) (2.5.1)
where Rt is the resistance at temperature T (⁰C) and R0 is the temperature at 0⁰C and α
is the constant for the metal termed as temperature coefficient of resistance. The sensor
is usually made to have a resistance of 100 Ω at 0 °C
Figure 2.5.2 Behavior of RTD materials [1]
Figure 2.5.3 shows the construction of a RTD. It has a resistor element connected to a
Wheatstone bridge. The element and the connection leads are insulated and protected
by a sheath. A small amount of current is continuously passing though the coil. As the
temperature changes the resistance of the coil changes which is detected at the
Wheatstone bridge.
RTDs are used in the form of thin films, wire wound or coil. They are generally made
of metals such as platinum, nickel or nickel-copper alloys. Platinum wire held by a high-
temperature glass adhesive in a ceramic tube is used to measure the temperature in a
metal furnace. Other applications are:
• Air conditioning and refrigeration servicing
• Food Processing
• Stoves and grills
• Textile production
• Plastics processing
• Petrochemical processing
• Micro electronics
• Air, gas and liquid temperature measurement in pipes and tanks
• Exhaust gas temperature measurement
3. Thermistors
Thermistors are available in the form of a bead (pressed disc), probe or chip. Figure
2.5.4 shows the construction of a bead type thermistor. It has a small bead of dimension
from 0.5 mm to 5 mm coated with ceramic or glass material. The bead is connected to
an electric circuit through two leads. To protect from the environment, the leads are
contained in a stainless steel tube.
Applications of Thermistors
• To monitor the coolant temperature and/or oil temperature inside the engine
• To monitor the temperature of an incubator
• Thermistors are used in modern digital thermostats
• To monitor the temperature of battery packs while charging
• To monitor temperature of hot ends of 3D printers
• To maintain correct temperature in the food handling and processing industry
equipment.
• To control the operations of consumer appliances such as toasters, coffee
makers, refrigerators, freezers, hair dryers, etc.
4. Thermocouple
Thermocouple works on the fact that when a junction of dissimilar metals heated, it
produces an electric potential related to temperature. As per Thomas Seebeck (1821),
when two wires composed of dissimilar metals are joined at both ends and one of the
ends is heated, then there is a continuous current which flows in the thermoelectric
circuit. Figure 2.5.5 shows the schematic of thermocouple circuit. The net open circuit
voltage (the Seebeck voltage) is a function of junction temperature and composition of
two metals. It is given by,
∆VAB = α ∆T (2.5.2)
Applications of Thermocouples
Light sensors
A light sensor is a device that is used to detect light. There are different types of light
sensors such as photocell/photoresistor and photo diodes being used in manufacturing
and other industrial applications.
Photoresistor is also called as light dependent resistor (LDR). It has a resistor whose
resistance decreases with increasing incident light intensity. It is made of a high
resistance semiconductor material, cadmium sulphide (CdS). The resistance of a CdS
photoresistor varies inversely to the amount of light incident upon it. Photoresistor
follows the principle of photoconductivity which results from the generation of mobile
carriers when photons are absorbed by the semiconductor material.
Figure 2.5.6 shows the construction of a photo resistor. The CdS resistor coil is mounted
on a ceramic substrate. This assembly is encapsulated by a resin material. The sensitive
coil electrodes are connected to the control system though lead wires. On incidence of
high intensity light on the electrodes, the resistance of resistor coil decreases which will
be used further to generate the appropriate signal by the microprocessor via lead wires.
Photoresistors are used in science and in almost any branch of industry for control,
safety, amusement, sound reproduction, inspection and measurement.
Figure 2.5.7 shows the construction of Photo diode detector. It is constructed from
single crystal silicon wafers. It is a p-n junction device. The upper layer is p layer. It is
very thin and formed by thermal diffusion or ion implantation of doping material such
as boron. Depletion region is narrow and is sandwiched between p layer and bulk n type
layer of silicon. Light irradiates at front surface, anode, while the back surface is
cathode. The incidence of light on anode generates a flow of electron across the p-n
junction which is the measure of light intensity.
Industry
• Bar Code Scanners
• Light Pens
• Brightness Controls
• Encoders
• Position Sensors
• Surveying Instruments
• Copiers - Density of Toner
Safety Equipment
• Smoke Detectors
• Flame Monitors
• Security Inspection Equipment - Airport X ray
• Intruder Alert - Security System
Automotive
• Headlight Dimmer
• Twilight Detectors
• Climate Control - Sunlight Detector
Communications
• Fibre Optic Links
• Optical Communications
• Optical Remote Control.