Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Proportional Pressure Reducing Cartridge M22 X 1,5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Proportional pressure reducing valve

Proportional pressure reducing cartridge​


◆◆direct operated by means of pilot spool M22 x 1,5
◆◆Qmax = 20 l/min ISO 7789
◆◆pmax = 350 bar

◆◆pN red max = 200 bar
   

DESCRIPTION  ​ APPLICATION  ​
Direct operated proportional pressure reducing valve with pilot These valves are used in hydraulic systems where the pressure has
spool actuation in screw-in cartridge construction for cavity to be changed frequently. The electrical remote control in conjunc-
according to ISO 7789. Proportionally to the solenoid current, the tion with process controls allows economical solutions with repea-
solenoid force and the pressure in port A (1) rise. The valve func- table processes. The screw-in cartridge is perfectly suitable for
tions practically independently of the pressure in port P (2). Pres­ installation in control blocks and is installed in sandwich- (vertical
sure increase in the consumer port A (1) to above the adjusted stacked systems) and in flange plates (corresponding data sheets
value, e.g. through an active consumer, is avoided by discharging in this register). Direct operated pressure reducing valves are used
excess oil to the tank T (3). With the solenoid deenergised, the oil where a low minimal adjustable pressure is required. For machining
flows freely from consumer port A (1) to port T (3). For the control, the cartridge cavity in steel and aluminum blocks, cavity tools are
Wandfluh proportional amplifiers are available (see register 1.13). ​​​ available (hire or purchase). Please refer to the data sheets in
register 2.13. ​​

SYMBOL  ​ ACTUATION  ​
​ Actuation Proportional solenoid, wet pin push
(A) 1 type, pressure tight
Execution W.S37 / 19 x 50 (Data sheet 1.1-173)
M.S35 / 19 x 50 (Data sheet 1.1-174)
Connection Connector socket EN 175301 – 803
(P) 2 (T) 3 Connector socket AMP Junior-Timer
​  Connector Deutsch DT04 – 2P

STANDARDS  ​ INSTALLATION NOTES  ​


Cartridge cavity ISO 7789 Mounting type Screw-in cartridge M22 x 1,5
Solenoids DIN VDE 0580 Mounting position Any, preferably horizontal
Connection execution D EN 175301 – 803 Tightening torque MD = 60 Nm Screw-in cartridge
Protection class EN 60 529 MD = 5 Nm knurled nut
Contamination efficiency ISO 4406 MD = 9,5 Nm HB0
MD = 5,5 Nm HB4,5

www.wandfluh.com  Illustrations are not binding  Data subject to change 1/4 Edition: 18 35  2.3-625 E
Proportional pressure reducing valve

TYPE CODE  ​
M P P PM22 - - / - #
Pressure reducing valve

Direct operated by means of pilot spool

Proportional

Screw-in cartridge M22 x 1,5

Nominal pressure range pN red 20 bar 20 115 bar 115


80 bar 80 200 bar 200

Nominal voltage UN 12 VDC G12


24 VDC G24
without coil X5

Slip-on coil Metal housing round W


Metal housing square M

Connection execution Connector socket EN 175301 - 803 / ISO 4400 D


Connector socket AMP Junior - Timer J
Connector Deutsch DT04 - 2P G

Sealing material NBR


FKM (Viton) D1

Manual override Manual override HB4,5


Screw plug HB0

Design index (subject to change)


2.3-625

GENERAL SPECIFICATIONS  ​ HYDRAULIC SPECIFICATIONS  ​


Designation Proportional pressure reducing valve Working pressure pmax = 350 bar
Construction Direct operated by means of pilot spool Nominal pressure PN red = 20, 80, 115, 200 bar
Mounting Screw-in cartridge construction range
Nominal size M22 x 1,5 according to ISO 7789 Minimum adjustable < 1 bar
Actuation Proportional solenoid pressure
Ambient temperature -25…+70 °C Volume flow range See characteristic
Weight 0,55 kg Leakage oil at psys = 350 bar
MTTFd 150 years < 30 ml/min for pN red = 20, 80, 115 bar
< 50 ml/min for pN red = 200 bar
Hysteresis ≤ 4 % at optimal dither signal
Repeatability ≤ 1 % at optimal dither signal
ELECTRICAL SPECIFICATIONS  ​
Fluid Mineral oil, other fluid on request
Viscosity range 12 mm2/s…320 mm2/s
Protection class Connection execution D: IP65
Temperature range -25…+70 °C (NBR)
Connection execution J: IP66
fluid -20…+70 °C (FKM)
Connection execution G: IP67 and IP69K
Contamination Class 18 / 16 / 13
Relative duty factor 100 % DF
efficiency
Standard nominal 12 VDC, 24 VDC
Filtration Required filtration grade ß 6…10 ≥ 75,
voltage
see data sheet 1.0-50
Limiting current at IG = 1360 mA (UN = 12VDC)
50 °C IG = 680 mA (UN = 24VDC)
Note! Other electrical specifications see data sheet 1.1-173
(slip-on coil W) and 1.1-174 (slip-on coil M)

www.wandfluh.com  Illustrations are not binding  Data subject to change 2/4 Edition: 18 35  2.3-625 E
Proportional pressure reducing valve

PERFORMANCE SPECIFICATIONS  ​
Oil viscosity u = 30 mm2/s
p =f (Q) Pressure volume flow characteristic p =f (Q) Pressure volume flow characteristic
Maximal adjustable pressure Minimal adjustable pressure
p [bar] p [bar]
K4167 K4168
300 100
90
250 80
200 pN red = 200 bar 70
60
150 50
pN red = 115 bar 40
100 30
pN red = 80 bar
50 20
pN red = 20 bar 10
0 0
25 20 15 10 5 0 5 10 15 20 25 25 20 15 10 5 0 5 10 15 20 25
AT Q [l/min] PA AT Q [l/min] PA
​  ​ 
p =f (I) Pressure adjustment characteristics
Bis IG = 40 % leicht erhöhte Hysterese
pred [bar]
K4169
200 pN red = 200 bar
180
160
140
120 pN red = 115 bar
100
80 pN red = 80 bar
60
40
20 pN red = 20 bar
0
0 10 20 30 40 50 60 70 80 90 100 I [%]

​ 

ACCESSORIES  ​ MANUAL OVERRIDE  ​

Proportional amplifier Register 1.13 HB4,5


Optionally: Screw plug (HB0), no actuation possible
Electric plug B (black) Article no. 219.2002
Technical explanations Data sheet 1.0-100
Hydraulic fluids Data sheet 1.0-50
Filtration Data sheet 1.0-50

SURFACE TREATMENT  ​ SEALING MATERIAL  ​


◆◆The cartridge body, the slip-on coil and the armature tube are NBR or FKM (Viton) as standard, choice in the type code
zinc-nickel coated

www.wandfluh.com  Illustrations are not binding  Data subject to change 3/4 Edition: 18 35  2.3-625 E
Proportional pressure reducing valve

DIMENSIONS  ​ HYDRAULIC CONNECTION  ​


​ Cavity drawing according to ISO 7789–22–04–0–98

M22x1.5
s30

M22x1.5
15
MD= 5.5Nm
76.8

(3)
(3) (2)
37.2

(1)
(2)
W=

12 17 10 18 50 70 60 80 90 (1)
MD= 5Nm
78.4 58.4
(1)
143
​ 
HB0 Note! For detailed cavity drawing and cavity tools see data
sheet 2.13-1004
15
MD= 9.5Nm
74.8

M = □35

10
​ 
PARTS LIST  ​

Position Article Description


10 206.2… W.S37 / 19 x 50
260.5… M.S35 / 19 x 50
12 154.2700 Knurled nut
15 253.8000 HB4,5 manual override
239.2033 HB0 Screw plug
17 160.2187 O-ring ID 18,72 x 2,62 (NBR)
18 160.2170 O-ring ID 17,17 x 1,78 (NBR)
50 160.2188 O-ring ID 18,77 x 1,78 (NBR)
160.6188 O-ring ID 18,77 x 1,78 (FKM)
60 160.2156 O-ring ID 15,60 x 1,78 (NBR)
160.6156 O-ring ID 15,60 x 1,78 (FKM)
70 049.8196 Backup ring PTSM rd 14,5 x 17,4 x 1,4
80 160.2140 O-ring ID 14,00 x 1,78 (NBR)
160.6141 O-ring ID 14,00 x 1,78 (FKM)
90 049.8176 Back-up ring PTSM rd 12,7 x 15,6 x 1,4

Wandfluh AG Postfach CH-3714 Frutigen


Tel. +41 33 672 72 72  Fax +41 33 672 72 12  sales@wandfluh.com

www.wandfluh.com  Illustrations are not binding  Data subject to change 4/4 Edition: 18 35  2.3-625 E