Precautions in Handling and Use of Valves: 1. Notes For Pipe Design

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

PRECAUTIONS IN HANDLING AND USE OF VALVES

Below are general precautions for safely using valves.


Precautions specific to each product are provided in a separate instruction manual. For details, please contact our nearest dis-
tribution agent or sales office.

1. Notes for pipe design

● Make sure that the working temperature and pressure are within ● Consult us when using a fluid containing slurry.
the tolerance range during operation.
● This product is not explosion-proof. Do not use it in explosive
(The maximum working pressure is the value including the water
hammer pressure. If the tolerance range is exceeded during use, atmospheres. (Doing so may cause breakage or explosion.)
the valve may be damaged.) ●
Operating pressure of pneumatic type automatic valve: The
standard operating pressure of pneumatic type is 0.4 MPa {4.1
● Select an appropriate material to use. (Some kinds of chemical
kgf/cm2}. When increasing the operating pressure, ensure that
may erode the surface of parts, causing breakage.) For details,
consult our nearest sales office in advance. the pressure is within the specified range of operating pressure.

● Do not joint with solvent adhesive or welding connection on


● When using a fluid that contains crystalline fluid, use it in a
differential plastic materials.(It may cause damage.)
condition where the fluid does not recrystallize. (The valve may
become unable to work properly.)

2. Notes for acceptance, transportation and storage

● Do not ride on the valve or place a ●


Do not allow the valve to come in
heavy object on the valve. (Doing so contact with coal tar, creosote (wood Creosote Pesticide
Coal tar

may cause breakage.) preservative agent), white ant


exterminating agent, pesticide, or
coating material. (Doing so may cause
swelling and resulting breakage.)

● Keep fire and hot object away from the


valve. (Doing so may cause ● Be very careful when hanging or slinging the valve. Do not stand
deformation, breakage or fire.) under the suspended object.

● Keep the valve in a cardboard box until


just before piping installation. Avoid
direct sunlight and store it indoors (at
room temperatures). Also avoid storing

Avoid direct sunlight and store it the valve in a place that may be
indoors. Also avoid storing the valve in exposed to high temperatures.
a place that may be exposed to high (Cardboard boxes become weak
temperatures. (Doing so may cause when get wet. (Take due care when
deformation.) handling and storing the boxes.)

● When transporting the valve, do not


use the handle to secure the valve.
● Do not give an impact by throwing, dropping or hitting the valve.
(Doing so may cause damage or breakage.)

● Do not scratch or stick a sharp object


(such as a knife and hook) into the
valve.

After unpacking, check that the
product has no abnormality and
conforms to the specifications.

● Do not pile packed cardboard boxes


on top of another too much, to prevent
collapsing of the boxes.

241
3. Notes for commissioning of pipe

1) General precautions ● When tightening the union nut, pay attention to axial-center
● Secure an adequate space for maintenance and inspection. misalignment and face-to-face dimensions.

● Test completed items with hydraulic pressure. (Airtight test using ● When connecting a resin valve to a metal pipe, be careful that
air (gas) is very dangerous.) piping stress is given to the resin valve.

● When a positive pressure gas is used for our resin pipe, note that ● Do not over-tighten the union nut. (It may cause breakage.)
a dangerous situation may occur due to the reaction force
peculiar to compressed fluids even when the pressure is the 3) Notes for connection of flange
same as the hydraulic pressure. Always take appropriate ●
Ensure that the parallelism and axial-center misalignment
measures to ensure the safety of surrounding area, such as dimensions do not exceed the values below. (Failure to do so
coating the pipe with a protecting material. If you have any may cause breakage due to the stress given on the piping.)
uncertainty, please contact us.
AXIAL-CENTER
SIZE (mm) MISALIGNMENT PARALLELISM
After the completion of piping work, perform a leak test of the 40 — 80 1.0mm 0.8mm
( MISALIGNMENT )
AXIAL-CENTER (PARALLELISM)
a
conduit with hydraulic pressure. If it is inevitable to perform a test 100 — 150 1.0mm 1.0mm
with air, be sure to consult our nearest sales office in advance. 200 — 600 1.5mm 1.0mm

Avoid using in places that are
b
constantly exposed to water, dust or
direct sunlight. Or, cover the whole
product. (The valve may become
unable to work properly.)
( )
AXIAL-CENTER (PARALLELISM)

Tighten the bolts and
MISALIGNMENT nuts of the
a
connection flange diagonally according
to the specified torque.
(Failure to do so may cause leak or
● When using the valve in unfavorable conditions, it is recommended breakage.)
b
to cover the whole valve with a protective plastic bag. The
automatic driving parts, in particular, may have a malfunction due
to corrosion. ● The connection flanges recommended
● When supporting the pipe with a U-band, be careful not to over- to be flat face type.
tighten. (It may cause breakage.)

● Beforestarting the work, be sure to perform safety check of


mechanical and electric tools to be used.


During piping work, always use
protective equipment appropriate for
the work. (Failure to do so may cause ● Check that the flange standard of both sides are not different.
injury.)


Be sure to tighten the flanges using sealing gaskets (AV
packings), bolts, nuts, and washers, according to the specified
tightening torque (except for butterfly valves).
● During installation, be careful not to give a forcible stress, such
as tension, compression, bending and impact, on the piping and
valves.

● Before replacement of valve or parts, completely remove the fluid 4) Notes for connection of socket (bonding) type
from the pipe. If the fluid cannot be removed, reduce the fluid ● During installation at low temperatures, be very careful because
pressure to zero. the solvent fume is difficult to evaporate and liable to remain. (It
may cause a solvent crack and resulting breakage.) After piping
2) Notes for connection of true union type work, open the both sides of the pipe and ventilate the inside
● Duringpiping installation, assembly or disassembly, steady the using a blower (of low pressure type) to remove the solvent fume.
end connector.

Do not apply too much adhesive.
● Before a water flow test, be sure to (Doing so may cause a solvent crack
check that the union nut is securely Tighten and resulting breakage.)
until snug
tightened.

242
▶3. Notes for commissioning of pipe

● Never stroke the component to insert 5) Notes for threaded connection


it. Doing so may cause the pipe to ● Check that joint screws are made of resin. (If a metal screw is
break. used for piping work, the end connector may be damaged.)

● For threaded joints of our resin pipe, use sealing tape. If fluid seal
or liquid gasket is used, a stress crack (environmental stress
crack) may occur.


When using adhesive, ventilate the ●
Do not over-tighten joint screws.
area well and avoid using fire nearby. (Doing so may cause breakage.)
Do not inhale the fume directly. * For notes for socket (fusion) connection, Squeeze
refer to the instruction manual of each
product. For details, please contact our
nearest distribution agent or sales
office.
● If the adhesive contacts the skin, remove it immediately. If you
feel sick or sense that something is wrong with your body,
immediately seek medical attention and receive appropriate
treatment.

● For adhesive, use only AV adhesive. (For U-PVC products, use


adhesive No. 32, No. 52 or No. 62. For C-PVC
products, use adhesive No. 88.)

● Before performing a water flow test,


wait until at least 24 hours have
passed since the completion of
bonding.

4. Notes for operation and maintenance

Open
● Do not open or close the valve when ● Before replacement of valve or parts, completely remove the fluid
Close
there is dust or foreign object in the from the pipe. If the fluid cannot be removed, reduce the fluid
fluid. pressure to zero.

● The valve body may be damaged due to freezing. In environments


where freezing may occur, remove the water in the pipe or take
anti-freezing measures using lagging materials.
● Perform periodic maintenance. (Temperature changes or aging
● Move the valve handle and lever slowly to reduce water hammer.
during long-term storage, operation stop or while in use may
cause leakage. For inspection items, refer to the instruction ● When disposing of the valve, always hand it over to a professional
manual of each product. For details, please contact our nearest waste disposal company.
distribution agent or sales office.)

243
Be sure to read the following description of our product warranty
● Always observe the specifications of and the precautions and instructions on using our product.

● We always strive to improve the quality and reliability, but cannot guarantee perfection. Therefore, should you intend to use this product
with any equipment or machinery that may pose the risk of serious or even fatal injury, or property damage, ensure an appropriate safety
design or take other measures with sufficient consideration given to possible problems. We shall assume no responsibility for any
inconvenience stemming from any action on your part without our written consent in the form of specifications or other documented
approval.

● The related technical documents, operation manuals, and/or other documentation prescribe precautions on selecting, constructing,
installing, operating, maintaining, and servicing our products. For details, consult with our nearest distributor or agent.

● Our product warranty extends for one and a half years after the product is shipped from our factory or one year after the product is
installed, whichever comes first. Any product abnormality that occurs during the warranty period or which is reported to us will be
investigated immediately to identify its cause. Should our product be deemed defective, we shall assume the responsibility to repair or
replace it free of charge.

● Any repair or replacement needed after the warranty period ends shall be charged to the customer.

● The warranty does not cover the following inconveniences by:


(1) Using our product under any condition not covered by our defined scope of warranty.
(2) Failure to observe our defined precautions or instructions regarding the construction, installation, handling, maintenance, or servicing
of our product.
(3) Any product other than ours.
(4) Remodeling, or otherwise modifying our product by anyone other than us.
(5) Using any part of our product for anything other than the intended use of the product.

In no event shall we be responsible or liable for any special, indirect, incidental or consequential damages arising in any way in connection
with any products.

[Precautions]
* Our product warranty shall not apply in case of using a positive-pressure gas with our plastic piping. Using a positive-pressure gas
with our plastic piping may pose a dangerous condition due to the repellent force peculiar to compressed fluids, even when the gas
is under the same pressure as water. Therefore, be sure to take the necessary safety precautions such as covering the piping with
protective material. For inquiries, please contact us.
For conducting a leak test on newly installed piping, be sure to check for leaks under water pressure.
* Wrap the threaded joints on our plastic piping with sealing tape.
* Using a liquid sealing agent or liquid gasket may cause stress cracks (environmental stress cracking). Our product warranty shall not
apply in case of said use, even when said use is unavoidable.

Export Control
In an effort to remain compliant with international agreements on security, many countries have instituted export controls for advanced
goods and technologies which may be used for the proliferation of weapons of mass destruction.
Even in Japan we are sanctioned by the International Export Control Regime and the Chemical Weapons Convention to meet current
regulations at home and in countries where we sell our goods and technologies.
In meeting this social and legal obligation, we are asking for your cooperation in providing us information relating to the intended use
of our products. Information such as copies of agreements, company organization chart and affidavits of end-use may be required
for export permission.
Your cooperation in this endeavor is greatly appreciated and our sales or Asahi distributor people are committed to working with you
to continue to provide the best products and services Asahi has to offer.