Section 09720 Wall Coverings
Section 09720 Wall Coverings
Section 09720 Wall Coverings
PART 1 - GENERAL
A. Drawings and general provisions of the Contract, including Conditions of Contract and
Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
B. Related Sections: The following Sections contain requirements that relate to this Section:
1.3 REFERENCES
A. All reference to standards, regulations and requirements of statutory bodies shall mean the
latest published editions at the time of contract. Product manufacture, testing and installation
shall comply with the following references unless otherwise stated in the specification or
otherwise approved.
1.4 SUBMITTALS
A. Product Data for each type of product specified. Include data on physical characteristics,
durability; fade resistance, and flame-resistance characteristics.
B. Shop Drawings showing location and extent of each wall covering type. Indicate seams and
termination points.
C. Samples for initial selection in the form of manufacturer’s colour charts consisting of actual
units or sections of units showing the full range of colours, textures, and patterns available.
D. Samples for verification in sets for each colour, texture, and pattern specified, showing the full
range of variations expected in these characteristics.
1. Wall Covering Material: Full-width sample, not less than 914mm long, from dye lot
used for the Work.
a. Submit sample with specified treatments applied.
b. Mark top and face of material.
c. Show complete pattern repeat.
F. Product certificates signed by manufacturers of wall coverings certifying that their products
comply with specified requirements.
G. Maintenance data for wall covering to include in the operation and maintenance manual
specified in Division 1 Sections.
A. Quality System: Furnish products and materials produced by manufacturer holding valid ISO
9001/9002 Quality System certificates.
B. Installer Qualifications: Engage an experienced installer who has completed 5 projects similar
in material, design, and extent to that indicated for this Project and with a record of successful
in-service performance.
D. Mock-up: The Contractor shall submit wall covering mock-up for the approval of the Engineer.
The mock-ups shall be erected with materials approved by Engineer under sample submittal.
The mock-ups shall be full wall height and not less than 2.20 meters in width and shall show
pattern module and joint and other aesthetic effects. Mock-up approved by the Engineer may
become part of the permanent works if undisturbed or damaged at time of Substantial
completion as judged solely by the Engineer.
A. Space Enclosure and Environmental Limitations: Do not install wall covering until space is
enclosed and weatherproof, wet-work in space is completed and nominally dry, work above
ceilings is complete, and ambient temperature and humidity conditions are and will be
continuously maintained at values near those indicated for final occupancy.
B. Lighting: Do not install wall covering until a lighting level of not less than 160 lux is provided
on the surfaces to receive wall covering.
C. Ventilation: Provide continuous ventilation during installation and for not less than the time
recommended by the wall covering manufacturer for full drying or curing.
PART 2 - PRODUCTS
E. Colour and Pattern: As indicated in Finish Schedule and verified by sample approved
by the Engineer. Data sheet of fabric is to indicate for any stain
protection time allowable or available to remove stain before
penetrating through the fabric. Post sprayed-on protection
coating shall not be accepted.
2.2 ADHESIVES
A. General: Mildew-resistant, non-staining adhesive, for use with specific wood-veneer wall
covering and substrate application, as recommended by wall covering manufacturer.
2.3 ACCESSORIES
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates for compliance with requirements for moisture content and other
conditions affecting performance of Work of this Section. Do not proceed with installation until
unsatisfactory conditions have been corrected.
3.2 PREPARATION
B. Clean substrates of substances that could impair wall covering’s bond, including mould,
mildew, oil, grease, incompatible primers, and dirt.
C. Prepare substrates to achieve a smooth, dry, clean surface free of flaking, unsound coatings,
cracks, and defects.
D. Check painted surfaces for pigment bleeding. Sand gloss, semi-gloss, and eggshell finishes
with fine sandpaper.
E. Install wall liner, with no gaps or overlaps, where required by wall covering manufacturer.
Form smooth wrinkle-free surface for finished installation. Do not begin wall covering
installation until wall liner has dried.
F. Acclimatize wall covering materials by removing them from packaging in the installation areas
not less than 24 hours before installation.
A. General: Comply with wall coverings manufacturers’ written installation instructions applicable
to products and applications indicated, except where more stringent requirements apply.
B. Cut wall covering panels in roll number sequence. Change run numbers at partition breaks
and corners only.
D. Match pattern 1830mm above finish floor, unless otherwise directed by the Engineer.
E. Install seams vertical and plumb at least 150mm from outside corners and 75 mm from inside
corners, No horizontal seams.
G. Trim edges for colour uniformity, pattern match, and tight closure at seams and edges. Butt
seams.
3.4 CLEANING
A. Remove excess adhesive at finished seams, perimeter edges, and adjacent surfaces.