Producto: EXCAVATOR
Modelo: 330B L EXCAVATOR 6DR
Configuración: 330B L Excavator 6DR00001-UP (MACHINE) POWERED BY
3306 Engine
Pruebas y Ajustes
308B, 311B, 312B, 315B, 317B, 318B, 320B, 322B, 325B, 330B, M325B and W330B
Excavators Engine and Pump Control
Número de medio -RENR1998-06 Fecha de publicación -01/10/2004 Fecha de actualización -06/10/2004
i01261370
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 22/11/2008
330B L Excavator 6DR00001-UP (MACHINE) POWERED BY 3306 Engine(SEB... Página 2 de 3
Illustration 1 g00667434
This function is used to calibrate the proportional reducing valve. This calibration must be performed
when the proportional reducing valve or the controller is replaced.
Note: For proper operation of this function, the engine must be running with the engine speed dial
switch in position 10 and the hydraulic oil must be at approximately 50 °C (122 °F).
1. Attach a 4900 kPa (711 psi) pressure gauge to the power shift pressure port of the main pump.
3. Activate the service mode in order to calibrate the proportional reducing valve.
First, display (1) indicates the calibration point. "H" is displayed for the high pressure point
and "L" is displayed for the low pressure point. The value of the correction is the last digit that
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 22/11/2008
330B L Excavator 6DR00001-UP (MACHINE) POWERED BY 3306 Engine(SEB... Página 3 de 3
is displayed.
5. Perform the following operations in order to calibrate the low pressure point and the high
pressure point.
a. Depress fine control mode switch (4) in order to shift the blinking character. Position the
blinking character to the third position from the right.
b. Depress boom priority mode switch (2) in order to shift the calibration point. Shift to the
high pressure point. "71H0".
c. Depress swing priority mode switch (3) in order to shift the calibration point. Shift to the
high pressure point. "71L0".
d. Depress fine control mode switch (4) in order to shift the position of the character that is
blinking. Shift the position of the character that is blinking to the position to the right.
e. Depress boom priority mode switch (2) or swing priority mode switch (3) in order to
locate the point that provides the most adequate pressure gauge reading.
f. When boom priority mode switch (2) is depressed, the power shift pressure will
INCREASE by 1 step.
g. When swing priority mode switch (3) is depressed, the power shift pressure will
DECREASE by 1 step.
Note: The power shift pressure changes approximately 9 kPa (1.3 psi) per step.
6. Set the increments of the step for the power shift pressure.
a. Depress travel alarm cancel switch (6) in order to set the new values.
When the new value is set, the position of the blinking character does not change. The
third position from the right flashes "H" to "L".