SERIES 4000: Oil & Gas
SERIES 4000: Oil & Gas
SERIES 4000: Oil & Gas
SERIES 4000
GenDrive engines for the Oil & Gas Industry
Engine
Displacement, total l (cu in) 12V: 57.2 (3491); 16V: 76.3 (4655); 20V: 95.4 (5822)
Continuous operation
3A Load factor: ≤ 100 %, operating hours: unrestricted, overload: 10% capability (ICXN)
w/100% load
Continuous operation
3B Load factor: < 75%, operating hours: unrestricted, overload: 10% capability (ICXN)
w/variable load
Standby operation
3C Load factor: < 75%, operating hours: max. 1000/yr, overload: 10% capability (ICXN)
w/variable load
Power output within 5% tolerance at standard conditions. Power definition according to ISO 3046 (ratings also correspond to SAE J 1995 and SAE J 1349 standard conditions)
Consult your distributor/dealer for the rating that will apply to your specific application.
Continuous power Prime power Prime power limited
3A 3B 3C
Optimization 1, 7 1, 7 1, 7
Optimization 1, 7 1, 6, 7 1, 6, 7
Optimization 7 3, 7 3, 7
Optimization 6, 7 3, 6, 7 3, 6, 7
Optimization 6, 7 2, 6, 7 2, 6, 7
Common rail injection system, double-walled high pressure injection pipes with
Fuel system
monitoring, duplex fuel filters with changeover valves
Lube oil system Automatic lube oil filter with lube oil centrifuge, closed crankcase breather system
Water cooled exhaust gas manifolds and turbo-chargers < 220°C, vertical exhaust gas
Exhaust gas system
outlets
HT (JW) and LT (CAC) coolant circuits with coolant pumps, coolant thermostats for HT
Cooling system
(JW) and LT (CAC)
ADEC engine control and management system, extended sensor scope for offshore
Electronics and instrumentation
application
Optional equipment
Lube oil system Special oil sump for increased inclinations up to 25° in all directions
Air filters engine mounted, heavy duty air filters (shipped loose), electrically operated air
Combustion air system
shut-off flaps
Exhaust gas system Horizontal exhaust gas outlet, exhaust gas bellows with counter flanges
Accessory drives Add PTO’s for hyd. pump drives, battery charging alternator, 28 VDC/120 A
EMU (Engine Monitoring Unit) with extended sensor scope for classification, redundant
Electronics and instrumentation
electronic controller for NFPA20 standard
Certification 3rd party certification (DNV, LRS, ABS, BV, GL & RS), ATEX (Zone II)
Reference conditions:
> Charge air coolant temp.: 45°C (113° F)
> Ambient air pressure: 1000 mbar (14.5 psi)
> Altitude above sea level: 100 m (328 ft)
> Rated power available up to 40°C (104°F) and 400 m (1312 ft)
Rolls-Royce Group
www.mtu-solutions.com