Ac-Dc Power Supply: Owner'S Manual
Ac-Dc Power Supply: Owner'S Manual
Ac-Dc Power Supply: Owner'S Manual
Model No.
SEC - 1212G
SEC - 1225G
SEC - 1235G
SEC - 2412G
OWNER’S MANUAL
Please read this manual before operating your power supply
TABLE OF CONTENTS
Topic Page
Specifications ..................................................................... 7
1.) It Is recommended that you return your power supply to a qualified Samlex dealer
for any service or repair. Incorrect assembly may result in electric shock or fire.
2.) To reduce the risk of electric shock, unplug power supply from outlet before attempting
any maintenance or cleaning. Turning off controls will not reduce this risk.
3.) An extension cord should not be used unless absolutely necessary. If an extension
cord must be used make sure that the pins on the plug are the same number, size and shape
as those of the original power supply plug.
4.) Place the unit in an area that will allow air to flow freely around the unit. DO NOT
block or obstruct vent openings on the side/bottom of the unit.
WARNING
Your power supply should be grounded to reduce the risk of electric shock.
The power supply is equipped with grounding conductor and grounding plug.
The cord must be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinances. Never alter the AC cord of plug provided.
If the cord will not fit the outlet, have a proper outlet installed by qualified electrician.
Improper connection can result in risk of electric shock.
1
DESCRIPTION
SEC-1212G, SEC-1225G and SEC 1235G are switched mode power supplies which convert
120V-240Vac, 50-60 Hz to regulated 13.8 VDC based on pulse width modulation ( PWM ) control.
The SEC-2412G converts 120V-240Vac, 50-60Hz to 27.6 VDC.
FEATURES
NOTE! The DC output connector has a tubular hole of diameter 0.2” (5mm) with a set
screw. For a firm connection, crimp/solder a pin type copper terminal on the cable ends
of your 12V DC or 24V DCdevice.
Ensure that the power supply’s ON/OFF switch is off and it is unplugged from the AC
outlet. Switch off your 12 or 24V DC device and connect it’s positive and negative to the
RED ( Positive ) and WHITE ( Negative ) terminals respectively. Ensure that the connections
are secure and tight. Plug the power supply into the AC outlet. Press the ON/Off switch of
the power supply to ON and observe that the neon indicator in the switch illuminates. If
the indicator fails to light , recheck the connection, AC outlet and the fuse inside the
power supply.
2
COOLING AND FAN CONTROL / THERMAL SHUT DOWN (SEC-1225G/1235G AND 2412G)
SEC-1225G/1235G and 2412G are cooled by convection and forced air. A temperature controlled
fan has been provided to improve cooling at higher loads. The fan is controlled by a sensor
mounted on the power transformer. THE FAN WILL BE OFF AT LOWER LOADS.
It will come on only when the temperature of the power transformer is above 70¼C due to
higher loads. In case the fan fails or the air flow is blocked, a second temperature sensor
mounted on the power transformer will activate over temperature shut down at 100¼C.
The output voltage will be automatically resumed once the unit cools down.
PLACE THE UNIT IN A WELL VENTILATED OPEN AND COOL AREA.
DO NOT BLOCK THE OPENINGS AT THE FAN SUCTION ON THE BOTTOM
AND THE DISCHARGE OPENINGS ON THE SIDES .
!
WARNING ! THESE UNITS ARE POWER SUPPLIES AND NOT BATTERY CHARGERS.
DO NOT CONNECT THESE UNITS DIRECTLY TO A BATTERY
3
TROUBLESHOOTING -GENERAL
PROBLEM : Power ON/OFF switch does not illuminate when turned on.
AC side fuse inside the power Replace the fuse inside the unit.
supply is blown See fuse ratings at page 8
Input voltage is very low Check that the input voltage is 120V- 240Vac
The unit is in current limit condition Check the output terminals are not
due to overload caused by large reactive shorted. Remove the load. If the output
loading or by the output being voltage gets restored, the load is shorted
short circuited or is offering large reactive impedance.
Unit is shut down due to over Check that the fan has not failed or
temp. (SEC-1225G/1235G/2412G) the vent openings are not blocked
4
SWITCHING POWER SUPPLIES AND RF NOISE
1 Switched mode power supplies ( SMPS ) employ high frequency switching and thus,
are a source of radio interference, a recipient of radio interference and a conduit of
radio interference. ( Older linear type transformer based power supplies do not employ
high frequency switching voltages and will be quieter as compared to switching type
of supplies ).
2 The primary emission sources originate in the switching devices due to their fast switching
current transitions: harmonics of the switching frequency and broadband noise created by
under-damped oscillations in the switching circuit. The secondary source is from the bridge
rectifier, both rectifier noise and diode recovery. The AC input rectifier / capacitor front end
of the switching power supplies ( excepting those with power factor correction ) are
notorious for generating power supply harmonics due to the non linear input current
waveform. The noise is both conducted and radiated through the input power cord and
the DC output wiring to the radio.
3 Switching power supplies are also recipients of radio interference. The normal operation
of the power supply can be disturbed due to RF noise getting coupled into the power supply.
Thus, the power supply may generate excessive RF noise and lose output voltage regulation
due to excessive transmitter energy being coupled through the AC / DC lines to the power
supply’s regulator feedback path. This may be due to antenna being too close or due to the
antenna or feed system not radiating properly. First check the antenna system SWR. Then,
if necessary, relocate either the antenna or the power supply farther apart.
4 The receiver may “hear” the power supply. A slowly moving, slightly buzzing carrier heard
in the receiver may be caused by the antenna being too close. As with the transmitter related
noise pick up, a loose coaxial connector or a broken or a missing ground may aggravate this
problem. Normally these noises will be below the background or “band” noise. Increase the
separation between the power supply and the receiving antenna. Use an outdoor antenna.
This will reduce the amount of signal picked up from the power supply and also increase
the amount of the desired signal.
5 The conducted and radiated RF noise from these power supplies is limited by internal
filtration. These RF noise currents are filtered and bypassed to the chassis of the power
supply. The chassis is, in turn, connected to the earth ground pin of the ac input power cord.
Thus, the chassis of the power supply is connected to the earth ground of the 120V-240 Vac
distribution system. The net RF noise generated by these power supplies complies with
the limits laid down in the European Standards for emissions and immunity.
5
6. Following additional guidelines may be followed to reduce the effects of RF noise:
c The positive and negative terminals of the dc output side of the power
supply are isolated from its chassis. As pointed out at para 5 above, all
the noise currents that are internally filtered are by passed to the chassis
of the power supply and onward to the earth ground of the 120V-240 Vac
system through the earth ground pin of the power cord. Therefore, the
negative terminal of the power supply should never be connected /
bonded to the chassis of the power supply.
d Twist the positive and negative wires from the output of the power supply
to the radio
6
SPECIFICATION
MODEL NO. SEC-1212G SEC-1225G SEC-2412G SEC-1235G
OUTPUT VOLTAGE: 13.8 VDC +/- 1% 13.8 VDC +/- 1% 27.6 VDC +/- 1% 13.8 VDC +/- 1%
DC OUTPUT CONNECTION: TUBULAR HOLE DIA 0.2" (5MM) WITH SET SCREW
ENERGY EFFICIENCY
CEC / Doe / MEPS NO REQUIRED NO REQUIRED NO REQUIRED
CERTIFICATION
7
2 YEAR Limited Warranty
The SEC 1212G/1225G/1235G/2412G manufactured by Samlex Europe B.V. ( the “ Warrantor “ ) is
warranted to be free from defects in workmanship and materials under normal use and service.
This warranty is in effect for 2 years from the date of purchase by the user ( the “ Purchaser “)
For a warranty claim, the Purchaser should contact the place of purchase to obtain a Return
Authorization Number.
The defective part or unit should be returned at the Purchaser’s expense to the authorized
location. A written statement describing the nature of the defect, the date of purchase,
the place of purchase, and the Purchaser’s name, address and telephone number should
also be included.
If upon the Warrantor’s examination, the defect proves to be the result of defective material
or workmanship, the equipment will be repaired or replaced at the Warrantor’s option without
charge, and returned to the Purchaser at the Warrantor’s expense.
No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable
to remedy the defect after having a reasonable number of opportunities to do so.
Warranty service shall be performed only by the Warrantor. Any attempt to remedy the defect
by anyone other than the Warrantor shall render this warranty void.
There shall be no warranty for defects or damages caused by faulty installation or hook-up,
abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water
spray, or water immersion.
No other express warranty is hereby given and there are no warranties which extend beyond
those described herein. This warranty is expressly in lieu of any other expressed or implied
warranties, including any implied warranty of merchantability, fitness for the ordinary
purposes for which such goods are used, or fitness for a particular purpose, or any other
obligations on the part of the Warrantor or its employees and representatives.
There shall be no responsibility or liability whatsoever on the part of the Warrantor or its
employees and representatives for injury to any persons, or damage to person or persons,
or damage to property, or loss of income or profit, or any other consequential or resulting
damage which may be claimed to have been incurred through the use or sale of the equipment,
including any possible failure of malfunction of the equipment, or part thereof.
The Warrantor assumes no liability for incidental or consequential damages of any kind.