www.victronenergy.com
250VA – 1200VA 230V and 120V, 50Hz or 60Hz
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two-pole connector, or between battery plus and the
left-hand contact of the two-pole connector.
LED diagnosis
Please see manual for a description.
GFCI
1. VRLA technology
VRLA stands for Valve Regulated Lead Acid, which means that the batteries are sealed. Gas will escape through the safety valves
only in case of overcharging or cell failure.
VRLA batteries are maintenance free for life.
Our AGM deep cycle batteries have excellent high current performance and are therefore recommended for high current
applications such as engine starting. Due to their construction, Gel batteries have a lower effective capacity at high discharge
currents. On the other hand, Gel batteries have a longer service life, both under float and cycling conditions.
Temperature (°C)
Depth of discharge
Fig. 2: Cycle life
10. Battery charging in case of cycle use: the 3-step charge curve
The most common charge curve used to charge VRLA batteries in case of cyclic use is the 3-step charge curve, whereby a
constant current phase (the bulk phase) is followed by two constant voltage phases (absorption and float), see fig. 3.
Charge voltage
Charge current
During the absorption phase the charge voltage is kept at a relatively high level in order to fully recharge the battery within
reasonable time. The third and last phase is the float phase: the voltage is lowered to standby level, sufficient to compensate for
self-discharge.
www.victronenergy.com
• Thereafter the absorption voltage is applied during a fixed period of time, irrespective of how deep the battery has
been discharged previously. A full absorption period after a shallow discharge will overcharge the battery, again
reducing service life (a.o. due to accelerated corrosion of the positive plates).
• Research has shown that battery life can be increased by decreasing float voltage to an even lower level when the
battery is not in use.
11. Battery charging: longer battery life with Victron 4-step adaptive charging
Victron developed the adaptive charge curve. The 4-step adaptive chare curve is the result of years of research and testing.
The Victron four-step adaptive charge curve solves the 3 main problems of the 3-step curve:
• Battery Safe Mode
In order to prevent excessive gassing, Victron has invented the ‘Battery Safe Mode’. The Battery Safe Mode will limit
the rate of voltage increase once the gassing voltage has been reached. Research has shown that this will reduce
internal gassing to a safe level.
• Storage mode
After completion of the absorption period the battery should be fully charged, and the voltage is lowered to the
float or standby level. If no discharge occurs during the next 24 hours, the voltage is reduced even further and the
battery goes into storage mode. The lower storage voltage reduces corrosion of the positive plates.
Once every week the charge voltage is increased to the absorption level for a short period to compensate for self-
discharge (Battery Refresh mode).
12. Battery charging in case of standby use: constant voltage float charging
When a battery is not frequently deeply discharged, a 2-step charge curve can be used. During the first phase the battery is
charged with a limited current (the bulk phase). Once a pre-set voltage has been reached the battery is kept at that voltage (the
float phase).
This charge method is used for starter batteries in vehicles and in uninterruptible power supplies (UPS).
The warranty does not cover cracked covers, cracked cases, bulged cases
from heat, freezing or explosion, discharged batteries or the use of
undersized batteries damaged from electrical equipment.
This warranty covers only manufacturing defects.
The Company makes no warranty with respect to its batteries other than
the warranty stated above. All implied warranties of merchantability and
all expressed and implied warranties of any other kind are hereby
excluded.
Batteries
Batteries are one of the most important external factors.
The battery cabling needs to be of a suitable thickness. The fuses, battery
isolators and battery connections need to be in good shape and all cable
connections need to be clean and tight. If any of these are of sub-standard
quality a voltage loss and/or a ripple voltage can occur. This will cause a
Victron product to shut down. Please see the product manual for a table on
recommended battery cable thicknesses.
Batteries can cause a lot of strange symptoms in a Victron product when
the battery is:
• Empty or almost empty
• Capacity too small
• Bad quality or too old
• Too hot or too cold
Bluetooth sensing:
BMV-712 Smart Battery Monitor
With VE.Can up to 25 Charge Controllers can be daisy-chained and connected to a Color Control GX or other GX device
Each Controller can be monitored individually, for example on a Color Control GX and on the VRM website
166 mm2
Highest reliability & Better performance Split junction box Reduced power PID resistant Sustain heavy M6 Mono
enhanced crack under all losses up to with long wind & snow loads PERC cells
tolerant 9BB climatic conditions 1/4 times term reliability (2400 pa & 5400 pa)
module
The Graphs are for reference purpose only. Please consult Waaree technical team for further clarifications.
100%
97.50%
81.90%
1 5 10 25
www.waaree.com
ARKA SERIES
WSMD-420 to WSMD-450
ELECTRICAL CHARACTERISTICS
Pmax (W) Vmp (V) Imp (A) Isc (A) Voc (V)
Models Module Eff. (%)
STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT
WSMD-420 420 314.7 40.61 37.40 10.35 8.42 11.04 8.93 49.01 45.70 19.32
WSMD-425 425 318.4 40.81 37.60 10.42 8.47 11.11 8.99 49.19 45.80 19.55
WSMD-430 430 322.2 41.01 37.70 10.49 8.55 11.19 9.05 49.39 46.00 19.78
WSMD-435 435 326.0 41.21 37.90 10.56 8.60 11.25 9.10 49.59 46.20 20.02
WSMD-440 440 329.8 41.41 38.10 10.63 8.65 11.34 9.17 49.69 46.30 20.25
WSMD-445 445 333.3 41.61 38.20 10.70 8.72 11.41 9.23 49.89 46.50 20.48
WSMD-450 450 336.8 41.81 38.50 10.77 8.75 11.46 9.27 50.10 46.70 20.71
*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.
Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.
MECHANICAL CHARACTERISTICS
Length x Width x Thickness (L x W x T) 2094 mm (L) x 1038 mm (W) x 35 mm (T)
Weight 23.5 kgs
Solar Cells per Module (Units) / Arrangement 144 cells / (12x6 || 12x6)
Solar Cell Type & Size Mono PERC
Front Glass 3.2 mm Low Iron and Tempered glass with ARC coating
Encapsulate PID Free & UV Resistant
Junction Box (Protection degree/ Material ) IP68 / Weatherproof PPO
Cable & Connector (Protection degree / Type) IP68 rated / MC4 compatible
Cable cross - section & Length 4 mm2 & 350mm
Frame Anodized Aluminium Alloy
NOCT (ºC) 43 ± 2
860.00±1.00 1728.00±1.00
Waaree Energies Ltd. is amongst the top Solar Energy Companies and has the
country's largest Solar PV Module manufacturing capacity of 2 GW. In addition, it
is committed to provide top notch EPC services, project development, rooftop
solutions, solar water pumps and also in an Independent Power Producer. Waaree
has its presence in over 325+ locations nationally and 68 countries globally.
Draining
Hole
*If you need specific product certificates, and if module installations are to deviate from our guidance
10 Years Product Warranty • 25 Years Power Output Warranty specified in our installation manual, please contact your local Waaree sales and technical representatives.
www.waaree.com
WEL/E&PD/420-450/144/MP/HC/CMZ79/01/22.01.2020
MultiPlus-II GX Inverter/Charger
\ 48/3000/35-32 GX
MultiPlus-II
Standard marine, mobile or off-grid application Standard mobile or off-grid application with external current sensor
Loads that should shut down when AC input power is not available can Maximum current sensing range: 50A resp 100A
be connected to a second output (not shown). These loads will be taken
into account by the PowerControl and PowerAssist function in order to
limit AC input current to a safe value when AC power is available.
Grid parallel topology with MPPT solar charge controller Grid in-line topology with PV inverter
The MultiPlus-II will use data from the external AC current sensor PV power is directly converted to AC.
(must be ordered separately) or power meter to optimise self- The MultiPlus-II will use excess PV power to charge the batteries or to feed power
consumption and, if required, to prevent grid feed. In case of a power back into the grid, and will discharge the battery or use power from the grid to
outage, the MultiPlus-II will continue to supply the critical loads supplement a shortage of PV power. In case of a power outage, the MultiPlus-II
will disconnect the grid and continue to supply the loads.
MultiPlus-II GX 48/3000/35-32
INVERTER/CHARGER
PowerControl & PowerAssist Yes
Transfer switch 32A
Maximum AC input current 32A
Auxiliary output Yes (32A)
INVERTER
Input voltage range 38 – 66V
Output voltage: 230 VAC ± 2%
Output
Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25°C (3) 3000VA / 2400W
Cont. output power at 40°C / 65°C 2200W / 1700W
VRM Portal Maximum apparent feed-in power 2500VA
Our free remote monitoring website (VRM) will display all your
Peak power 5500W
system data in a comprehensive graphical format. System settings
can be changed remotely via the portal. Alarms can be received Maximum efficiency 95%
by e-mail. Zero load power 11W
Zero load power in AES mode 7W
Zero load power in Search mode 2W
CHARGER
Input voltage range: 187-265 VAC
AC Input
Input frequency: 45 – 65 Hz
Charge voltage 'absorption' 57,6V
Charge voltage 'float' 55,2V
Storage mode 52,8V
Maximum battery charge current (4) 35A
Battery temperature sensor Yes
Programmable relay (5) Yes
Protection (2) a-g
For parallel and three phase operation,
VE.Bus communication port
remote monitoring and system integration
General purpose com. port Yes, 2x
GENERAL
VRM app for Wi-Fi Interfaces VE.Can, USB, Ethernet, VE.Direct, Wi-Fi
Monitor and manage your Victron Energy system from Remote on-off Yes
your smart phone and tablet. Available for both iOS and Operating temp. range -40 to +65°C (fan assisted cooling)
Android.
Humidity (non-condensing): max 95%
ENCLOSURE
Material & Colour Steel, blue RAL 5012
Protection category IP21
Battery-connection M8 bolts
230 V AC-connection Screw terminals 13 mm2 (6 AWG)
Weight 26kg
Dimensions (hxwxd) 506 x 275 x 147 mm
STANDARDS
EN-IEC 60335-1, EN-IEC 60335-2-29
Safety
EN-IEC 62109-1, EN-IEC 62109-2
EN 55014-1, EN 55014-2
Emission / Immunity EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
GX GSM Anti-islanding See our website
A cellular modem; providing a mobile internet for the system
1) Can be adjusted to 60 Hz 3) Non-linear load, crest factor 3:1
and connection to Victron Remote Management (VRM). 2) Protection key: 4) At 25°C ambient
Optional: outdoor GSM antenna and GPS antenna. a) output short circuit 5) Programmable relay which can be set for general alarm,
For more detail please enter GX GSM in the search box on b) overload DC under voltage or genset start/stop function.
our website c) battery voltage too high AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up
d) battery voltage too low to 60VDC
e) temperature too high
f) 230 VAC on inverter output
g) input voltage ripple too high
Bluetooth sensing
Smart Battery Sense
SmartSolar Charge Controller MPPT 100/30 MPPT 100/50
Battery voltage 12/24V Auto Select
Rated charge current 30A 50A
Nominal PV power, 12V 1a,b) 440W 700W
Nominal PV power, 24V 1a,b) 880W 1400W
Maximum PV open circuit voltage 100V 100V
Max. PV short circuit current 2) 35A 60A
Maximum efficiency 98% 98%
Self-consumption 12V: 30 mA 24V: 20 mA
Charge voltage 'absorption' Default setting: 14,4V / 28,8V (adjustable)
Charge voltage 'float' Default setting: 13,8V / 27,6V (adjustable)
Bluetooth sensing Charge algorithm multi-stage adaptive
BMV-712 Smart Battery Monitor Temperature compensation -16 mV / °C resp. -32 mV / °C
PV reverse polarity
Protection Output short circuit
Over temperature
Operating temperature -30 to +60°C (full rated output up to 40°C)
Humidity 95%, non-condensing
VE.Direct
Data communication port
See the data communication white paper on our website
ENCLOSURE
Colour Blue (RAL 5012)
Power terminals 16 mm² / AWG6
Protection category IP43 (electronic components), IP22 (connection area)
Weight 1,3 kg
Dimensions (h x w x d) 130 x 186 x 70 mm
STANDARDS
Safety EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.
2 3 5
11
13 B B
4
12 15
DEWA
LOGO
BILL OF MATERIALS
250 ITEM DESCRIPTION MATERIAL DIMENSION QTY
A -
LEFT SIDE ELEVATION FRONT ELEVATION SECTION A A 1 Lift-off hinges SS316 4
2 Heavy Duty Handle Lock Zinc Alloy - 1
635 3 3 Point Cam & Tie Rod Set SS316 - 1
4 Mounting Stud SS316 M10 x 40 12
5 Mounting Plate 1 Galvanized Iron 1220H x 540W x 2.8 thk. 1
5 6 Mounting Plate 2 Galvanized Iron 1220H x 340W x 2.8 thk. 1
7 Gland Plate (loose supply) Galvanized Iron 400W x 300D x 2.8 thk. 1
8 Gasket EPDM & PVC - -
6 9 Roof Canopy GRP - 1
10 Lifting Hooks SS316 M12 2
11 Padlock Facility SS316 - 1
12 Door Stay SS316 - 1
13 IP44 Ventilators Polyamide - 4
8 14 Provision for Light & Limit switch - - -
SECTION B B
15 DEWA logo - - -
QTY.: 12 Nos. 16
DRAWN BY: S.I APPROVED BY: S.S DATE: 29/09/2021 SCALE: NTS