Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Solar Datasheet CCTV

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Phoenix Inverters

www.victronenergy.com
250VA – 1200VA 230V and 120V, 50Hz or 60Hz

VE.Direct communication port


The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
Phoenix 12/375 VE.Direct
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 - 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Phoenix 12/375 VE.Direct
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.

High start-up power


Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.

ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.

Remote on/off
A remote on/off switch can be connected to a two-pole connector, or between battery plus and the
left-hand contact of the two-pole connector.

LED diagnosis
Please see manual for a description.

To transfer the load to another AC source: the automatic transfer switch


For our low power inverters, we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.

Available with different output sockets

Schuko UK AU/NZ IEC-320 Nema 5-15R


(male plug included)

GFCI

DC connection with screw terminals


No special tools needed for installation
12 Volt 12/250 12/375 12/500 12/800 12/1200
Phoenix Inverter 24 Volt 24/250 24/375 24/500 24/800 24/1200
48 Volt 48/250 48/375 48/500 48/800 48/1200
Cont. power at 25°C (1) 250VA 375VA 500VA 800VA 1200VA
Cont. power at 25°C / 40°C 200 / 175W 300 / 260W 400 / 350W 650 / 560W 1000 / 850W
Peak power 400W 700W 900W 1500W 2200W
Output AC voltage / frequency (adjustable) 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
DC low shut down (adjustable) 9,3 / 18,6 / 37,2V
Dynamic (load dependent) DC low shut down Dynamic cut-off, see
(fully configurable) https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
DC low restart and alarm (adjustable) 10,9 / 21,8 / 43,6V
Battery charged detect (adjustable) 14,0 / 28,0 / 56,0V
Max. efficiency 87 / 88 / 88% 89 / 89 / 90% 90 / 90 / 91% 90 / 90 / 91% 91 / 91 / 92%
Zero-load power 4,2 / 5,2 / 7,9W 5,6 / 6,1 / 8,5W 6 / 6,5 / 9W 6,5 / 7 / 9,5W 7 / 8 / 10W
Default zero-load power in ECO mode
0,8 / 1,3 / 2,5W 0,9 / 1,4 / 2,6W 1 / 1,5 / 3,0W 1 / 1,5 / 3,0W 1 / 1,5 / 3,0W
(default retry interval: 2,5 s, adjustable)
ECO mode stop and start power setting Adjustable
Protection (2) a-f
Operating temperature range -40 to +65°C (fan assisted cooling) Derate 1,25% per °C above 40°C
Humidity (non-condensing) max 95%
ENCLOSURE
Material & Colour Steel chassis and plastic cover (blue Ral 5012)
Battery-connection Screw terminals
25 / 10 / 10mm² / 35 / 25 / 25mm2 /
Maximum cable cross-section 10mm² / AWG8 10mm² / AWG8 10mm² / AWG8
AWG4 / 8 / 8 AWG2 / 4 / 4
230V: Schuko (CEE 7/4), IEC-320 (male plug included)
Standard AC outlets UK (BS 1363), AU/NZ (AS/NZS 3112)
120V: Nema 5-15R, GFCI
Protection category IP 21
Weight 2,4kg / 5,3lbs 3,0kg / 6,6lbs 3,9kg / 8.5lbs 5,5kg / 12lbs 7,4kg / 16,3lbs
105 x 216 x 305 117 x 232 x 327
Dimensions (h x w x d, mm) 86 x 165 x 260 86 x 165 x 260 86 x 172 x 275 4.1 x 8.5 x 12.1 4.6 x 9.1 x 12.9
(h x w x d, inch) 3.4 x 6.5 x 10.2 3.4 x 6.5 x 10.2 3,4 x 6,8 x 10,8 (12V model: (12V model:
105 x 230 x 325) 117 x 232 x 362)
ACCESSORIES
Remote on-off Yes
Automatic transfer switch Filax
STANDARDS
Safety EN-IEC 60335-1 / EN-IEC 62109-1
EMC EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3
Automotive Directive ECE R10-4
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high

Battery Alarm BMV Battery Monitor


An excessively high or low battery voltage is indicated The BMV Battery Monitor features an advanced microprocessor control system combined
by an audible and visual alarm, and a relay for remote with high resolution measuring systems for battery voltage and charge/discharge current.
signalling. Besides this, the software includes complex calculation algorithms to exactly determine
the state of charge of the battery. The BMV selectively displays battery voltage, current,
consumed Ah or time to go. The monitor also stores a host of data regarding performance
and use of the battery.

VE.Direct Bluetooth Smart dongle


(must be ordered separately)

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Gel and AGM Batteries
www.victronenergy.com

1. VRLA technology
VRLA stands for Valve Regulated Lead Acid, which means that the batteries are sealed. Gas will escape through the safety valves
only in case of overcharging or cell failure.
VRLA batteries are maintenance free for life.

2. Sealed (VRLA) AGM Batteries


AGM stands for Absorbent Glass Mat. In these batteries the electrolyte is absorbed into a glass-fibre mat between the plates by
capillary action. As explained in our book ‘Energy Unlimited’, AGM batteries are more suitable for short-time delivery of high
currents than gel batteries.

3. Sealed (VRLA) Gel Batteries


Here the electrolyte is immobilized as gel. Gel batteries in general have a longer service life and better cycle capacity than AGM
AGM Battery batteries.
12V 90Ah
4. Low Self-Discharge
Because of the use of lead calcium grids and high purity materials, Victron VRLA batteries can be stored during long periods of
time without recharge. The rate of self-discharge is less than 2% per month at 20°C. The self-discharge doubles for every
increase in temperature by 10°C.
Victron VRLA batteries can therefore be stored for up to a year without recharging, if kept under cool conditions.

5. Exceptional Deep Discharge Recovery


Victron VRLA batteries have exceptional discharge recovery, even after deep or prolonged discharge.
Nevertheless repeatedly deep and prolonged discharge has a very negative effect on the service life of all lead acid batteries,
Victron batteries are no exception.

6. Battery Discharging Characteristics


The rated capacity of Victron AGM and Gel Deep Cycle batteries refers to 20 hour discharge, in other words: a discharge current
of 0,05 C.
The rated capacity of Victron Tubular Plate Long Life batteries refers to 10 hours discharge.
The effective capacity decreases with increasing discharge current (see table 1). Please note that the capacity reduction will be
even faster in case of a constant power load, such as an inverter.

End AGM Gel Gel


Discharg time
Voltage ‘Deep ‘Deep ‘Long
(constant
Cycle’ Cycle’ Life’
current)
V % % %
20 hours 10,8 100 100 112
10 hours 10,8 92 87 100
GEL OPzV 2V cell 5 hours 10,8 85 80 94
3 hours 10,8 78 73 79
1 hour 9,6 65 61 63
30 min. 9,6 55 51 45
15 min. 9,6 42 38 29
10 min. 9,6 38 34 21
5 min. 9,6 27 24
5 seconds 8C 7C

Table 1: Effective capacity as a function of discharge time


(the lowest row gives the maximum allowable 5 seconds discharge current)

Our AGM deep cycle batteries have excellent high current performance and are therefore recommended for high current
applications such as engine starting. Due to their construction, Gel batteries have a lower effective capacity at high discharge
currents. On the other hand, Gel batteries have a longer service life, both under float and cycling conditions.

7. Effect of temperature on service life


High temperature has a very negative effect on service life. The service life of Victron batteries as a function of temperature is
shown in table 2.

AGM Gel Gel


Average ‘Deep ‘Deep ‘Long
Temperature Cycle’ Cycle’ Life’

years years years


20°C / 68°F 7 - 10 12 20
30°C / 86°F 4 6 10
40°C / 104°F 2 3 5

Table 2: Design service life of Victron batteries under float service


www.victronenergy.com

8. Effect of temperature on capacity


As is shown by the graph below, capacity reduces sharply at low temperatures.

Temperature (°C)

Fig. 1: Effect of temperature on capacity


9. Cycle life of Victron batteries
Batteries age due to discharging and recharging. The number of cycles depends on the depth of discharge, as is shown in figure
2.

AGM Deep Cycle Gel Deep Cycle Gel Long Life


Cycles

Depth of discharge
Fig. 2: Cycle life

10. Battery charging in case of cycle use: the 3-step charge curve
The most common charge curve used to charge VRLA batteries in case of cyclic use is the 3-step charge curve, whereby a
constant current phase (the bulk phase) is followed by two constant voltage phases (absorption and float), see fig. 3.
Charge voltage

Charge current

Fig. 3: Three step charge curve

During the absorption phase the charge voltage is kept at a relatively high level in order to fully recharge the battery within
reasonable time. The third and last phase is the float phase: the voltage is lowered to standby level, sufficient to compensate for
self-discharge.
www.victronenergy.com

Disadvantages of the traditional 3-step charge curve:


• During the bulk phase the current is kept at a constant and often high level, even after the gassing voltage (14,34V
for a 12V battery) has been exceeded. This can lead to excessive gas pressure in the battery. Some gas will escape
through the safety valves, reducing service life.

• Thereafter the absorption voltage is applied during a fixed period of time, irrespective of how deep the battery has
been discharged previously. A full absorption period after a shallow discharge will overcharge the battery, again
reducing service life (a.o. due to accelerated corrosion of the positive plates).

• Research has shown that battery life can be increased by decreasing float voltage to an even lower level when the
battery is not in use.

11. Battery charging: longer battery life with Victron 4-step adaptive charging
Victron developed the adaptive charge curve. The 4-step adaptive chare curve is the result of years of research and testing.

The Victron four-step adaptive charge curve solves the 3 main problems of the 3-step curve:
• Battery Safe Mode
In order to prevent excessive gassing, Victron has invented the ‘Battery Safe Mode’. The Battery Safe Mode will limit
the rate of voltage increase once the gassing voltage has been reached. Research has shown that this will reduce
internal gassing to a safe level.

• Variable absorption time


Based on the duration of the bulk stage, the charger calculates how long the absorption time should be in order to
fully charge the battery. If the bulk time is short, this means the battery was already charged and the resulting
absorption time will also be short, whereas a longer bulk time will also result in a longer absorption time.

• Storage mode
After completion of the absorption period the battery should be fully charged, and the voltage is lowered to the
float or standby level. If no discharge occurs during the next 24 hours, the voltage is reduced even further and the
battery goes into storage mode. The lower storage voltage reduces corrosion of the positive plates.
Once every week the charge voltage is increased to the absorption level for a short period to compensate for self-
discharge (Battery Refresh mode).

12. Battery charging in case of standby use: constant voltage float charging
When a battery is not frequently deeply discharged, a 2-step charge curve can be used. During the first phase the battery is
charged with a limited current (the bulk phase). Once a pre-set voltage has been reached the battery is kept at that voltage (the
float phase).
This charge method is used for starter batteries in vehicles and in uninterruptible power supplies (UPS).

Fig. 4: Four-step adaptive charge curve

13. Optimum charge voltage of Victron VRLA batteries


The recommended charge voltage settings for a 12V battery are shown in table 3.

14. Effect of temperature on charging voltage


The charge voltage should be reduced with increased temperature. Temperature compensation is required when the
temperature of the battery is expected to be less than 10°C / 50°F or more than 30°C / 85°F during long periods of time.
The recommended temperature compensation for Victron VRLA batteries is -4 mV / Cell (-24 mV /°C for a 12V battery).
The centre point for temperature compensation is 25°C / 70°F.

15. Charge current


The charge current should preferably not exceed 0,2C (20A for a 100Ah battery).The temperature of a battery will increase by
more than 10°C if the charge current exceeds 0,2C. Therefore temperature compensation is required if the charge current
exceeds 0,2C.
www.victronenergy.com

Float Cycle service Cycle service


Service (V) Normal (V) Fastest recharge (V)
Victron AGM ‘Deep Cycle’
Absorption 14,2 - 14,6 14,6 - 14,9
Float 13,5 - 13,8 13,5 - 13,8 13,5 - 13,8
Storage 13,2 - 13,5 13,2 - 13,5 13,2 - 13,5
Victron Gel ‘Deep Cycle’
Absorption 14,1 - 14,4
Float 13,5 - 13,8 13,5 - 13,8
Storage 13,2 - 13,5 13,2 - 13,5
Victron Gel ‘Long Life’
Absorption 14,0 - 14,2
Float 13,5 - 13,8 13,5 - 13,8
Storage 13,2 - 13,5 13,2 - 13,5

Table 3: Recommended charge voltage

12 Volt Deep Cycle AGM General Specification


lxwxh Weight CCA RES CAP Technology: flat plate AGM
Article number Ah V mm kg @0°F @80°F Terminals: copper
BAT406225084 240 6 320 x 176 x 247 31 700 270 Rated capacity: 20 hr. discharge at 25°C
Float design life: 7-10 years at 20°C
BAT212070084 8 12 151 x 65 x 101 2,5
Cycle design life:
BAT212120084 14 12 151 x 98 x 101 4,1 400 cycles at 80% discharge
BAT212200084 22 12 181 x 77 x 167 5,8 600 cycles at 50% discharge
1500 cycles at 30% discharge
BAT412350084 38 12 197 x 165 x 170 12,5
BAT412550084 60 12 229 x 138 x 227 20 280 80
BAT412600084 66 12 258 x 166 x 235 24 300 90
BAT412800084 90 12 350 x 167 x 183 27 400 130
BAT412101084 110 12 330 x 171 x 220 32 500 170
BAT412121084 130 12 410 x 176 x 227 38 550 200
BAT412151084 165 12 485 x 172 x 240 47 600 220
BAT412201084 220 12 522 x 238 x 240 65 650 250
BAT412124081 240 12 522 x 240 x 224 67 650 250

12 Volt Deep Cycle GEL General Specification


lxwxh Weight CCA RES CAP Technology: flat plate GEL
Article number Ah V
mm kg @0°F @80°F Terminals: copper
BAT412550104 60 12 229 x 138 x 227 20 250 70 Rated capacity: 20 hr. discharge at 25°C
Float design life: 12 years at 20°C
BAT412600100 66 12 258 x 166 x 235 24 270 80
Cycle design life:
BAT412800104 90 12 350 x 167 x 183 26 360 120 500 cycles at 80% discharge
BAT412101104 110 12 330 x 171 x 220 33 450 150 750 cycles at 50% discharge
1800 cycles at 30% discharge
BAT412121104 130 12 410 x 176 x 227 38 500 180
BAT412151104 165 12 485 x 172 x 240 48 550 200
BAT412201104 220 12 522 x 238 x 240 66 600 220
BAT412126101 265 12 520 x 268 x 223 75 650 250

2 Volt Long Life GEL General Specification

lxbxh Weight Technology: tubular plate GEL


Article number Ah V mm kg Terminals: copper
BAT702601260 600 2 145 x 206 x 688 49 Rated capacity: 10 hr. discharge at 25°C
Float design life: 20 years at 20°C
BAT702801260 800 2 210 x 191 x 688 65
Cycle design life:
BAT702102260 1000 2 210 x 233 x 690 80 1500 cycles at 80% discharge
BAT702122260 1200 2 210 x 275 x 690 93 2500 cycles at 50% discharge
4500 cycles at 30% discharge
BAT702152260 1500 2 210 x 275 x 840 115
BAT702202260 2000 2 215 x 400 x 815 155
BAT702252260 2500 2 215 x 490 x 815 200
BAT702302260 3000 2 215 x 580 x 815 235

Other capacities and terminal types: at request

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Warranty Terms and Conditions for Victron Energy Products
For Batteries

One Year limited warranty From Date of Purchase

In case of a battery warranty need the following information:

• Information about the system


• Photos
• BMV historical data (without BMV no warranty). A Battery Monitor has to
purchase along with the battery to avoid warranty issues.

The warranty does not cover cracked covers, cracked cases, bulged cases
from heat, freezing or explosion, discharged batteries or the use of
undersized batteries damaged from electrical equipment.
This warranty covers only manufacturing defects.
The Company makes no warranty with respect to its batteries other than
the warranty stated above. All implied warranties of merchantability and
all expressed and implied warranties of any other kind are hereby
excluded.

Batteries
Batteries are one of the most important external factors.
The battery cabling needs to be of a suitable thickness. The fuses, battery
isolators and battery connections need to be in good shape and all cable
connections need to be clean and tight. If any of these are of sub-standard
quality a voltage loss and/or a ripple voltage can occur. This will cause a
Victron product to shut down. Please see the product manual for a table on
recommended battery cable thicknesses.
Batteries can cause a lot of strange symptoms in a Victron product when
the battery is:
• Empty or almost empty
• Capacity too small
• Bad quality or too old
• Too hot or too cold

A battery problem can make a Victron product appear to be faulty. In case


of a Multi you can see: a totally dead unit, a low battery light or the overload
and low battery light blink or light up simultaneously. In this case the first
point of action is to measure the battery voltage under no load and under
load. If the battery voltage drops significantly under load the batteries are
empty or faulty.
Undercharged batteries are most often due to a large DC load in the
system. The DC loads in a system can consume more power than the Multi
or the charger can deliver. Another reason for undercharged batteries can
be that the batteries are too large for the charger. Overcharged batteries
can be caused by a very small or faulty battery bank.
www.victronenergy.com
SmartSolar Charge Controllers with VE.Can interface
MPPT 250/70 VE.Can up to MPPT 250/100 VE.Can

Ultra-fast Maximum Power Point Tracking (MPPT)


Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast
MPPT controller will improve energy harvest by up to 30 % compared to PWM charge controllers
and by up to 10 % compared to slower MPPT controllers.
Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power (MPP) points may be present on the
power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative SmartSolar algorithm will always maximize energy harvest by locking to the
optimum MPP.
Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 99 %.
Flexible charge algorithm
SmartSolar Charge Controller Fully programmable charge algorithm, and eight pre-programmed algorithms, selectable with a
MPPT 250/100-Tr VE.Can rotary switch (see manual for details).
with optional pluggable display
Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
Bluetooth Smart built-in
The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
Internal temperature sensor and optional external battery voltage, temperature and current
sensing via Bluetooth
A Smart Battery Sense, a BMV-712 Smart Battery Monitor or a SmartShunt can be used to
communicate battery voltage and temperature (and current, in case of a BMV 712 or a
SmartShunt) to one or more SmartSolar Charge Controllers.
SmartSolar Charge Controller
VE.Direct or VE.Can
MPPT 250/100-Tr VE.Can
For a wired data connection to a Color Control GX, other GX products, PC or other devices.
without display
Synchronized parallel charging with VE.Can or Bluetooth
Up to 25 units can be synchronized with VE.Can, and up to 10 units with Bluetooth.
Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts.
Will reconnect to a fully discharged Li-ion battery with integrated disconnect function.
VE.Can: the multiple controller solution
Up to 25 units can be synchronised with VE.Can.
Remote on-off
Bluetooth sensing: To connect for example to a VE.BUS BMS.
Smart Battery Sense
Programmable relay
Can be programmed to trip on an alarm,
or other events.
Optional: SmartSolar pluggable LCD display
Simply remove the rubber seal that protects
the plug on the front of the controller,
and plug-in the display.

Bluetooth sensing:
BMV-712 Smart Battery Monitor

Bluetooth sensing: SmartShunt

SmartSolar pluggable display

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
SmartSolar Charge Controller
250/70 250/85 250/100
with VE.Can interface
Battery voltage 12/24/48 V Auto Select (36 V: manual)
Rated charge current 70 A 85 A 100 A
Nominal PV power, 12 V 1a,b) 1000 W 1200 W 1450 W
Nominal PV power, 24 V 1a,b) 2000 W 2400 W 2900 W
Nominal PV power, 36 V 1a,b) 3000 W 3600 W 4350 W
Nominal PV power, 48 V 1a,b) 4000 W 4900 W 5800 W
Max. PV short circuit current 2) 35 A (max 30 A per MC4 conn.) 70 A (max 30 A per MC4 conn.)
250 V absolute maximum coldest conditions
Maximum PV open circuit voltage
245 V start-up and operating maximum
Maximum efficiency 99 %
Self-consumption Less than 35 mA @ 12 V / 20 mA @ 48 V
Default setting: 14,4 / 28,8 / 43,2 / 57,6 V
Charge voltage 'absorption'
(adjustable with: rotary switch, display, VE.Direct or Bluetooth)
Default setting: 13,8 / 27,6 / 41,4 / 55,2 V
Charge voltage 'float'
(adjustable: rotary switch, display, VE.Direct or Bluetooth)
Charge voltage 'equalization' Default setting: 16,2 V / 32,4 V / 48,6 V / 64,8 V (adjustable)
Charge algorithm multi-stage adaptive (eight pre-programmed algorithms) or user defined algorithm
Temperature compensation -16 mV / -32 mV / -64 mV / °C
Protection PV reverse polarity / Output short circuit / Over temperature
Operating temperature -30 to +60 °C (full rated output up to 40 °C)
Humidity 95 %, non-condensing
Maximum altitude 5000m (full rated output up to 2000m)
Environmental condition Indoor, unconditioned
Pollution degree PD3
Data communication VE.Can, VE.Direct and Bluetooth
Remote on/off Yes (2 pole connector)
Programmable relay DPST AC rating: 240 VAC / 4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
Parallel operation Yes, parallel synchronised operation with VE.Can (max. 25 units) or Bluetooth (max. 10 units)
ENCLOSURE
Colour Blue (RAL 5012)
35 mm² / AWG2 (Tr models)
35 mm² / AWG2 (Tr models)
PV terminals 3) Two pairs of MC4 connectors (MC4
Three pairs of MC4 connectors (MC4 models)
models)
Battery terminals 35mm² / AWG2
Protection category IP43 (electronic components), IP22 (connection area)
Weight 3 kg 4,5 kg
Tr models: 185 x 250 x 95 mm Tr models: 216 x 295 x 103
Dimensions (h x w x d) in mm
MC4 models: 215 x 250 x 95 mm MC4 models: 246 x 295 x 103
STANDARDS
Safety EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5 V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1 V.
2) A PV array with a higher short circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
Maximum current per MC4 connector: 30 A (the MC4 connectors are parallel connected to one MPPT tracker)

With VE.Can up to 25 Charge Controllers can be daisy-chained and connected to a Color Control GX or other GX device
Each Controller can be monitored individually, for example on a Color Control GX and on the VRM website

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
ARKA SERIES
WSMD-420 to WSMD-450

166 mm2

Highest reliability & Better performance Split junction box Reduced power PID resistant Sustain heavy M6 Mono
enhanced crack under all losses up to with long wind & snow loads PERC cells
tolerant 9BB climatic conditions 1/4 times term reliability (2400 pa & 5400 pa)
module

I-V VARIATION WITH IRRADIANCE

I-V VARIATION WITH TEMPERATURE

The Graphs are for reference purpose only. Please consult Waaree technical team for further clarifications.

100%
97.50%

Linear Performance Warranty


91.65%
Standard Performance Warranty

81.90%

1 5 10 25

ISO 9001:2015 l ISO 14001:2015 l ISO 45001:2018


Independent assessment of factories by BLACK & VEATCH

www.waaree.com
ARKA SERIES
WSMD-420 to WSMD-450
ELECTRICAL CHARACTERISTICS
Pmax (W) Vmp (V) Imp (A) Isc (A) Voc (V)
Models Module Eff. (%)
STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT
WSMD-420 420 314.7 40.61 37.40 10.35 8.42 11.04 8.93 49.01 45.70 19.32
WSMD-425 425 318.4 40.81 37.60 10.42 8.47 11.11 8.99 49.19 45.80 19.55
WSMD-430 430 322.2 41.01 37.70 10.49 8.55 11.19 9.05 49.39 46.00 19.78
WSMD-435 435 326.0 41.21 37.90 10.56 8.60 11.25 9.10 49.59 46.20 20.02
WSMD-440 440 329.8 41.41 38.10 10.63 8.65 11.34 9.17 49.69 46.30 20.25
WSMD-445 445 333.3 41.61 38.20 10.70 8.72 11.41 9.23 49.89 46.50 20.48
WSMD-450 450 336.8 41.81 38.50 10.77 8.75 11.46 9.27 50.10 46.70 20.71
*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.
Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.

System Voltage 1500 V Series Fuse Rating 20 A

MECHANICAL CHARACTERISTICS
Length x Width x Thickness (L x W x T) 2094 mm (L) x 1038 mm (W) x 35 mm (T)
Weight 23.5 kgs
Solar Cells per Module (Units) / Arrangement 144 cells / (12x6 || 12x6)
Solar Cell Type & Size Mono PERC
Front Glass 3.2 mm Low Iron and Tempered glass with ARC coating
Encapsulate PID Free & UV Resistant
Junction Box (Protection degree/ Material ) IP68 / Weatherproof PPO
Cable & Connector (Protection degree / Type) IP68 rated / MC4 compatible
Cable cross - section & Length 4 mm2 & 350mm
Frame Anodized Aluminium Alloy

DESIGN SPECIFICATIONS THERMAL CHARACTERISTICS


Temperature coefficient of Current (Isc), α (%/ºC) 0.055
1000.00±1.00

Temperature coefficient of Voltage (Voc), ß (%/ºC) -0.285

Temperature coefficient of Power (Pm), γ (%/ºC) -0.365


Mounting Hole
8No's.-10X6.5

NOCT (ºC) 43 ± 2

Operating temperature range (ºC) -40 to 85

860.00±1.00 1728.00±1.00

-VE TERMINAL +VE TERMINAL

Waaree Energies Ltd. is amongst the top Solar Energy Companies and has the
country's largest Solar PV Module manufacturing capacity of 2 GW. In addition, it
is committed to provide top notch EPC services, project development, rooftop
solutions, solar water pumps and also in an Independent Power Producer. Waaree
has its presence in over 325+ locations nationally and 68 countries globally.
Draining
Hole

*If you need specific product certificates, and if module installations are to deviate from our guidance
10 Years Product Warranty • 25 Years Power Output Warranty specified in our installation manual, please contact your local Waaree sales and technical representatives.

• The electrical data given here is for reference purpose only.


• Please confirm your exact requirements with the sales representative while placing your order.
• Refer installation Manual instructions & Waaree warranty statement for terms & conditions.
• Waaree Reserves the right to change the specifications without prior notice.

www.waaree.com
WEL/E&PD/420-450/144/MP/HC/CMZ79/01/22.01.2020
MultiPlus-II GX Inverter/Charger
\ 48/3000/35-32 GX
MultiPlus-II

A MultiPlus-II with LCD and GX functionality


The MultiPlus-II GX integrates a MultiPlus-II inverter/charger and a GX device with a 2 x 16 character display.
Display and Wi-Fi
The display reads battery, inverter and solar charge controller parameters.
The same parameters can be accessed with a smartphone or other Wi-Fi enabled device.
GX device
The integrated GX device includes:
• A VE.Can interface. This can be used to connect to Victron VE.Can devices (eg VE.Can MPPTs), or the port can be
reconfigured via the Remote Console for use with a compatible CAN-bus Li-ion Battery.
• A USB port.
• A Ethernet port.
• A VE.Direct port.
Applications
The MultiPlus-II GX is intended for applications where additional interfacing with other products and/or remote
monitoring is required, such as on-grid or off-grid energy storage systems and certain mobile applications.
Parallel and three phase operation
Only one GX unit is needed in case of Parallel and three phase operation.

Standard marine, mobile or off-grid application Standard mobile or off-grid application with external current sensor
Loads that should shut down when AC input power is not available can Maximum current sensing range: 50A resp 100A
be connected to a second output (not shown). These loads will be taken
into account by the PowerControl and PowerAssist function in order to
limit AC input current to a safe value when AC power is available.

Grid parallel topology with MPPT solar charge controller Grid in-line topology with PV inverter
The MultiPlus-II will use data from the external AC current sensor PV power is directly converted to AC.
(must be ordered separately) or power meter to optimise self- The MultiPlus-II will use excess PV power to charge the batteries or to feed power
consumption and, if required, to prevent grid feed. In case of a power back into the grid, and will discharge the battery or use power from the grid to
outage, the MultiPlus-II will continue to supply the critical loads supplement a shortage of PV power. In case of a power outage, the MultiPlus-II
will disconnect the grid and continue to supply the loads.
MultiPlus-II GX 48/3000/35-32

INVERTER/CHARGER
PowerControl & PowerAssist Yes
Transfer switch 32A
Maximum AC input current 32A
Auxiliary output Yes (32A)
INVERTER
Input voltage range 38 – 66V
Output voltage: 230 VAC ± 2%
Output
Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25°C (3) 3000VA / 2400W
Cont. output power at 40°C / 65°C 2200W / 1700W
VRM Portal Maximum apparent feed-in power 2500VA
Our free remote monitoring website (VRM) will display all your
Peak power 5500W
system data in a comprehensive graphical format. System settings
can be changed remotely via the portal. Alarms can be received Maximum efficiency 95%
by e-mail. Zero load power 11W
Zero load power in AES mode 7W
Zero load power in Search mode 2W
CHARGER
Input voltage range: 187-265 VAC
AC Input
Input frequency: 45 – 65 Hz
Charge voltage 'absorption' 57,6V
Charge voltage 'float' 55,2V
Storage mode 52,8V
Maximum battery charge current (4) 35A
Battery temperature sensor Yes
Programmable relay (5) Yes
Protection (2) a-g
For parallel and three phase operation,
VE.Bus communication port
remote monitoring and system integration
General purpose com. port Yes, 2x
GENERAL
VRM app for Wi-Fi Interfaces VE.Can, USB, Ethernet, VE.Direct, Wi-Fi
Monitor and manage your Victron Energy system from Remote on-off Yes
your smart phone and tablet. Available for both iOS and Operating temp. range -40 to +65°C (fan assisted cooling)
Android.
Humidity (non-condensing): max 95%
ENCLOSURE
Material & Colour Steel, blue RAL 5012
Protection category IP21
Battery-connection M8 bolts
230 V AC-connection Screw terminals 13 mm2 (6 AWG)
Weight 26kg
Dimensions (hxwxd) 506 x 275 x 147 mm
STANDARDS
EN-IEC 60335-1, EN-IEC 60335-2-29
Safety
EN-IEC 62109-1, EN-IEC 62109-2
EN 55014-1, EN 55014-2
Emission / Immunity EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
GX GSM Anti-islanding See our website
A cellular modem; providing a mobile internet for the system
1) Can be adjusted to 60 Hz 3) Non-linear load, crest factor 3:1
and connection to Victron Remote Management (VRM). 2) Protection key: 4) At 25°C ambient
Optional: outdoor GSM antenna and GPS antenna. a) output short circuit 5) Programmable relay which can be set for general alarm,
For more detail please enter GX GSM in the search box on b) overload DC under voltage or genset start/stop function.
our website c) battery voltage too high AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up
d) battery voltage too low to 60VDC
e) temperature too high
f) 230 VAC on inverter output
g) input voltage ripple too high

Current sensor 100A:50mA Digital Multi Control Panel


To implement PowerControl and PowerAssist and A convenient and low-cost solution for remote
to optimize self-consumption with external monitoring, with a rotary knob to set
current sensing. PowerControl and PowerAssist levels.
Connection Area Maximum current: 50A resp. 100A.
Length of connection cable: 1 m.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
SmartSolar Charge Controllers MPPT 100/30 & 100/50
www.victronenergy.com

Bluetooth Smart built-in


The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
VE.Direct
For a wired data connection to a Color Control GX, other GX products, PC or other devices
Ultrafast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve
energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%.
The full output current up to 40°C (104°F).
Flexible charge algorithm
Fully programmable charge algorithm (see the software page on our website), and eight pre-programmed algorithms,
selectable with a rotary switch (see manual for details).
Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
Internal temperature sensor
Compensates absorption and float charge voltage for temperature.
SmartSolar Charge Controller
Optional external battery voltage and temperature sensing via Bluetooth
MPPT 100/50
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to
one or more SmartSolar Charge Controllers.
Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts.
Will reconnect to a fully discharged Li-ion battery with integrated disconnect function.

Bluetooth sensing
Smart Battery Sense
SmartSolar Charge Controller MPPT 100/30 MPPT 100/50
Battery voltage 12/24V Auto Select
Rated charge current 30A 50A
Nominal PV power, 12V 1a,b) 440W 700W
Nominal PV power, 24V 1a,b) 880W 1400W
Maximum PV open circuit voltage 100V 100V
Max. PV short circuit current 2) 35A 60A
Maximum efficiency 98% 98%
Self-consumption 12V: 30 mA 24V: 20 mA
Charge voltage 'absorption' Default setting: 14,4V / 28,8V (adjustable)
Charge voltage 'float' Default setting: 13,8V / 27,6V (adjustable)
Bluetooth sensing Charge algorithm multi-stage adaptive
BMV-712 Smart Battery Monitor Temperature compensation -16 mV / °C resp. -32 mV / °C
PV reverse polarity
Protection Output short circuit
Over temperature
Operating temperature -30 to +60°C (full rated output up to 40°C)
Humidity 95%, non-condensing
VE.Direct
Data communication port
See the data communication white paper on our website
ENCLOSURE
Colour Blue (RAL 5012)
Power terminals 16 mm² / AWG6
Protection category IP43 (electronic components), IP22 (connection area)
Weight 1,3 kg
Dimensions (h x w x d) 130 x 186 x 70 mm
STANDARDS
Safety EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
635 480
A
14 14
10
60
6
80
9

2 3 5

11

13 B B
4
12 15
DEWA
LOGO

BILL OF MATERIALS
250 ITEM DESCRIPTION MATERIAL DIMENSION QTY
A -
LEFT SIDE ELEVATION FRONT ELEVATION SECTION A A 1 Lift-off hinges SS316 4
2 Heavy Duty Handle Lock Zinc Alloy - 1
635 3 3 Point Cam & Tie Rod Set SS316 - 1
4 Mounting Stud SS316 M10 x 40 12
5 Mounting Plate 1 Galvanized Iron 1220H x 540W x 2.8 thk. 1
5 6 Mounting Plate 2 Galvanized Iron 1220H x 340W x 2.8 thk. 1
7 Gland Plate (loose supply) Galvanized Iron 400W x 300D x 2.8 thk. 1
8 Gasket EPDM & PVC - -
6 9 Roof Canopy GRP - 1
10 Lifting Hooks SS316 M12 2
11 Padlock Facility SS316 - 1
12 Door Stay SS316 - 1
13 IP44 Ventilators Polyamide - 4
8 14 Provision for Light & Limit switch - - -
SECTION B B
15 DEWA logo - - -
QTY.: 12 Nos. 16

1. FEATURES REVISION DRAWN CHECKED DATE DESCRIPTION


a. Ingress Protection: IP 55, BS EN 60529:1992 Certified, (Construction only) .
b. UV Resistant: ASTM G154 Certified. www.grpindustries.com
c. Fire Retardant and Self Extinguishing: BS 476:Part 7:1997 Class 2 Certified.
PROJECT CLIENT(S): NATHEER TECHNICAL SERVICES

PROJECT NAME: NATHEER TECH. PROJECT


2. SURFACE FINISH & THICKNESS
SHEET TITLE: GRP SINGLE DOOR ENCLOSURES
a. External finish: Plain semi gloss UV resistant white color gelcoat finish to RAL 9010.
b. Internal finish: Reasonable smooth flow coated finish to grey color. EXTERNAL SIZE: 1550 (H) x 635 (W) x 480 (D)
c. Wall thickness: 3mm GRP + 12mm WBP Plywood + 2mm GRP. INTERNAL SIZE: 1530 (H) x 590 (W) x 460 (D)

DRAWN BY: S.I APPROVED BY: S.S DATE: 29/09/2021 SCALE: NTS

DOCUMENT ID: GRPSTB150063048SS36985R0 SI 007 SHEET NO: 1/1 UNIT: mm.

You might also like