AIR PRESSURE
REDUCING VALVE
MODEL ACOS-10
SELF-ACTUATED PRESSURE REDUCING VALVE WITH SHOCK-ABSORBING PISTON

Features
Technologically advanced pressure
reducing valve combined with condensate
separator and air trap provides accurate
control and air conditioning to maximize
process system performance.
1. Space-saving unit simplifies system layout,
piping and maintenance.
2. Self-aligning shock-absorbing spherical
piston and advanced pilot regulator designs
maintain secondary air pressure accuracy,
even during adverse process conditions.
3. Built-in cyclone separator, with condensate
separation efficiency as high as 98%, and
self-modulating free float air trap provide dry,
high-quality air supply.
4. Major internal components made of stainless
steel for long service life.
5. Large surface area integral screens for pilot
valve and main valve extend trouble-free
service.
6. Internal secondary pressure-sensing channel
makes external sensing line unnecessary.

Specifications
Model ACOS-10
Connection Flanged
Size (mm) 15, 20, 25, 32, 40, 50
Body Material Cast Iron
Maximum Operating Pressure (MPaG) PMO 0.9
Maximum Operating Temperature (°C) TMO 100
Primary Pressure Range (MPaG) 0.1 – 0.9
Adjustable Pressure Range (MPaG) 0.05 – 0.7
Minimum Differential Pressure (MPa) 0.05
Minimum Adjustable Flow Rate 10% of rated flow rate
Applicable Fluid* Air
* Do not use for toxic, flammable or otherwise hazardous fluids. 1 MPa = 10.197 kg/cm2
PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (MPaG) PMA: 1.6
Maximum Allowable Temperature (°C) TMA: 220

To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of
CAUTION the specification range. Local regulations may restrict the use of this product to below the conditions quoted.
Dimensions
● ACOS-10 Flanged ACOS-10 Flanged (mm)
L L
Weight*
Size ASME Class H H1 W
(kg)
125FF (150RF) 250RF (300RF)
Rc (15) — 170 — 170 [15]
(PT) 3⁄8 495 285 105
(20) — 182 — 182 [16]

H1
25 176 188 188 192 522 282 150 21
32 206 220 220 25
220 572 302 165
40 209 222 224 27
H

50 255 255 260 261 635 315 195 43


( ) No ASME standard exists for cast iron; machined to fit steel flanges
Class 125 FF can connect to 150 RF, 250 RF can connect to 300 RF
Other standards available, but length and weight may vary
* Weight is for Class 250 RF [300 RF]

W
Rc(PT) 1⁄ 2

Sizing Chart Discharge Capacity


0.8 P1 = 0.9 Differential Pressure (kg/cm2)
0.7 0.1 0.3 1 3 5 9
0.7 P1 = Primary Pressure
Discharge Capacity (kg/h)
Secondary Pressure P2 (MPaG)

MPaG 300
0.6
200 50 mm
0.6
m
/40 m
0.5 100 25/32
0.5 80
mm
60
50 15/20
0.4
40
0.4
30
0.3 A 20
0.3
0.2 10
0.01 0.03 0.1 0.3 0.5 0.9
0.2
0.1
Differential Pressure (MPa)

0.1 1. Differential pressure is the difference between the inlet


0 pressure of the ACOS-10 and the outlet pressure of the trap.
50 mm
3000 2. Capacities are based on continuous discharge of condensate
40 mm below 100°C with specific gravity of 1.
2000 32 mm
Rated Flow Rate (m3/h)

25 mm
DO NOT use this product under conditions that exceed
1000
20 mm CAUTION maximum differential pressure, as condensate
700 backup will occur!
B
15 mm
500
Sizing Example (see sizing chart at left)
300
For primary pressure of 0.8 MPaG, set pressure 0.3 MPaG and
air flow rate 600 m3/h select an appropriate size.
200
1. Locate intersecting point A of 0.8 MPaG primary pressure and
0.3 MPaG set pressure. Go to point A and down until 600 m3/h,
100
point B, is reached.
80
2. Since point B is located between 20 mm and 25 mm, the larger
Rated flow rates represent equivalent flow rates of size, 25 mm, should be chosen.
air at 20°C under atmospheric pressure.