Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
102 views4 pages

Proposed Terminal Building: Archt. Herminiano R. Huelgas

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 4

A

OR T T I O N
SP

A
N

N
A

D
T OF TR
A B C D E F

COM M U N
EN
M

IC
RT IO
AT
NS DEPA

Republic of the Philippines


DEPARTMENT OF TRANSPORTATION
1 AND COMMUNICATIONS

COMMON DEPARTURE & ARRIVAL ROOM


REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS

CIVIL AVIATION AUTHORITY OF THE PHILIPPINES

PROJECT NAME :
FEMALE MALE
TOILET TOILET OFFICE CONSTRUCTION/RENOVATIONS
OF TOILET FACILITIES
4
LOCATION :

VIGAN AIRPORT
Vigan City, Ilocos Sur , Region I

PROPOSED TERMINAL BUILDING Prepared by & Submitted by:

NTS

Archt. Herminiano R. Huelgas


Actg. Division Chief III, IDDD - ADMS

PROPOSED TOILET FLOOR PLAN Recommending Approval:

NTS

GUILLERMO L. LEONARDO
O.I.C-Assistant Secretary for
Project Management

Approved:

ATTY. EFREN C. MONCUPA


Undersecretary for Project
Implementation and Special Concerns

Sheet Content:

PROPOSED TOILET FLOOR PLAN


NTS
Sheet No.:
- -
E - TS -
AT IO
OR T N
A B C D E F SP

A
N
A

N
D
T OF TR

CO M M U N
EN
TM

IC
AT
AR IO N
S DEP

EXHAUST DUCT OUTLET Republic of the Philippines


1 DEPARTMENT OF TRANSPORTATION
AND COMMUNICATIONS

(agency logo)
SEE TO ENGINEER'S DETAIL 82 GALS. CAPACITY
COMMON DEPARTURE & ARRIVAL ROOM PRESSURIZED TANK
(SANITARY) 1 HP WATER PUMP
REPUBLIC OF THE PHILIPPINES
WATER LINE
DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS

3 CIVIL AVIATION AUTHORITY OF THE PHILIPPINES

PRESSURIZED TANK
PROJECT NAME :
1HP WATER PUMP
OFFICE 20AT CIRCUIT BREAKER
CONSTRUCTION/RENOVATIONS
EXHAUST DUCT OUTLET
CISTERN TANK
OF TOILET FACILITIES FOR CAAP
(CAA. 2. CR. T1. D1. E1. L1. 1. 0..), ( CAA. 2. CR. T1. D1. E1. L1. 2.)
4
EXHAUST DUCT OUTLET
FROM SOURCE LOCATION :

VIGAN AIRPORT
Region I, Vigsn City, Ilocos Sur

PROPOSED TERMINAL PLAN PLAN OF WATER PUMP AND PRESSURE TANK ASSEMBLY Prepared by:

SCALE 1:375 mts NTS


HERMINIANO R. HUELGAS
Acting Division Chief III
Infrastructure Development and Design Division

Submitted by:

EDGARDO L. COSTES
Assistant Director General II, ADMS

Recommending Approval:

82 GALS. CAPACITY
PRESSURIZED TANK

GUILLERMO L. LEONARDO
O.I.C-Assistant Secretary for
GV GV
Project Management

1 HP WATER CV
3
GV PUMP 4" DIA. GI PIPE
FROM SOURCE (to toilets)

EXHAUST FAN LAYOUT PLAN (TYPE I)


NTS
3
4" DIA. OVERFLOW PIPE
(to existing drain)

Approved:

ATTY. EFREN C. MONCUPA


Undersecretary for Project
Implementation and Special Concerns
DET. OF WATER PUMP & PRESSURE PUMP ASSEMBLY Sheet Content:

NTS PROPOSED TERMINAL PLAN


PLAN OF WATER PUMP AND PRESSURE
TANK ASSEMBLY
DETAIL OF WATER PUMP AND
PRESSURE TANK ASSEMBLY
EXHAUST FAN LAYOUT PLAN (TYPE I) EXHAUST FAN LAYOUT PLAN (TYPE I & TYPE II)
NTS
Sheet No.:
1 -
M 3 TS -
A T IO
OR T N
SP

A
N
A

ND
T OF TR

CO M M U N
EN
TM

IC
AT
R IO
N S DE PA

Republic of the Philippines


DEPARTMENT OF TRANSPORTATION
AND COMMUNICATIONS
A B C D E F

PROJECT NAME :

CONSTRUCTION/RENOVATIONS
2 OF TOILET FACILITIES FOR CAAP
CAA. 2. CR. T1. D1. E1. L1. 1. 0.
COMMON DEPARTURE & ARRIVAL ROOM CAA. 2. CR. T1. D1. E1. L1. 2.

3
LOCATION :
VIGAN AIRPORT
FEMALE MALE Vigan City, Ilocos Sur , Region I
TOILET TOILET OFFICE
TOILET
LEGEND :

4 AREA TO BE DEMOLISHED Prepared by:


CONSTRUCTION/ RE-CONSTRUCTION OF
AFFECTED AREAS

RELOCATION OF DOORS &


WINDOWS
HERMINIANO R. HUELGAS
Acting Division Chief III,

EXISTING TERMINAL BUILDING Infrastructure Development and Design Division

Submitted by:
SCALE NTS

EDGARDO L. COSTES
Assistant Director General II,
Aerodrome Development and Management Division
A B C D E F

Recommending Approval:

1 GUILLERMO L. LEONARDO
O.I.C-Assistant Secretary for
Project Management

2 CAA. 2. CR. T1. D1. E1. L1. 1. 0.


CAA. 2. CR. T1. D1. E1. L1. 2.
COMMON DEPARTURE & ARRIVAL ROOM

FEMALE MALE Approved:


TOILET TOILET OFFICE
TOILET

ATTY. EFREN C. MONCUPA


Undersecretary for Project
Implementation and Special Concerns

PROPOSED TERMINAL BUILDING Sheet Content:

SCALE NTS FEXISTING FLOOR PLAN


PROPOSED FLOOR PLAN

Sheet No.:
- -
A - TS -
AT IO
4.40m OR T N
SP

A
N
A

N
D
T OF TR
0.20m 0.20m 0.90m 0.20m 0.90m 0.20m

CO M M U N
A B C D E F 1.80m

EN
TM

IC
0.20m
AT
AR IO N
S DEP

Republic of the Philippines


DEPARTMENT OF TRANSPORTATION

1.40m

1.00m
AND COMMUNICATIONS
1 SEWER LINE

0.20m
SEPTIC VAULT
PLAN

(agency logo)
2

PLAN OF SEPTIC VAULT


COMMON DEPARTURE & ARRIVAL ROOM SCALE 1:30 mts REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS

CIVIL AVIATION AUTHORITY OF THE PHILIPPINES


WATER LINE

3 PROJECT NAME :

0.10m
0.34m
PRESSURIZED TANK CONSTRUCTION/RENOVATIONS
FEMALE MALE
OFFICE
OF TOILET FACILITIES FOR CAAP

0.30m
TOILET TOILET TOILET (CAA. 2. CR. T1. D1. E1. L1. 1. 0..), ( CAA. 2. CR. T1. D1. E1. L1. 2.)
AIR SPACE
AIR SPACE AIR SPACE
WATER LEVEL
CISTERN TANK WATER LEVEL
WATER LEVEL LOCATION :
4

VIGAN AIRPORT

1.00m
FROM SOURCE
Region I, Vigsn City, Ilocos Sur

INLET SECONDARY TERTIARY


COMPARTMENT COMPARTMENT COMPARTMENT Prepared by:

0.15m
SECTION HERMINIANO R. HUELGAS
Acting Division Chief III
PROPOSED TERMINAL PLAN Infrastructure Development and Design Division

SCALE 1:375 mts


SECTION OF SEPTIC VAULT Submitted by:
SCALE 1:30 mts

EDGARDO L. COSTES
Assistant Director General II, ADMS

Recommending Approval:

SPECIFICATION:
1. THE LOCATION OF SEPTIC VAULT/ PRESSURIZED TANK SHALL BE MORE THAN 3.0 METERS AWAY FROM GUILLERMO L. LEONARDO
THE BUILDING LINE. 82 GALS. CAPACITY O.I.C-Assistant Secretary for
PRESSURIZED TANK Project Management
2. THE DISTANCE OF SEPTIC VAULT FROM PROPOSED CISTERN SHALL BE 15 METERS AWAY.
3. WATER PIPE LINE AND SEWER LINE RUNNING PARALLEL IN DIRECTION SHALL HAVE A MINIMUM DISTANCE GV GV
IN SEPARATION OF 0.50 METER AND AVOID INSTALLING WATER LINE BELOW SEWER LINE.
1 HP WATER CV
GV PUMP
4. THE STANDARD PLUMBING PLANS (COLD WATER LINE AND SEWER LINE) SHALL RE-CONFIGURATED AND FROM SOURCE MH
3
4" DIA. GI PIPE (to toilets)

SHALL REVISED DEFENDING ON THE ORIENTATION OF TOILET PLANS.


3
4" DIA. OVERFLOW PIPE

5. THE CONSTRUCTION SHALL BE SUPERVISED BY A LICENSE PLUMBER AND SHALL BE COVERED BY NATIONAL (to existing drain)

PLUMBING CODE OF THE PHILIPPINES.


12mm dia. bars spcd @ 0.20m Approved:
1.5m x 2.0m x o.c. b.w. (top & bottom)
1.5m(depth)
concrete underground
reservoir (4.50 cu.m.)

ATTY. EFREN C. MONCUPA


Undersecretary for Project
Implementation and Special Concerns

Sheet Content:

PROPOSED TERMINAL PLAN


SECTION OF CISTERN TANK
PLAN OF SEPTIC VAULT
SECTION OF CISTERN TANK SECTION OF SEPTIC VAULT
SPECIFICATION
NTS

Sheet No.:
1 -
P 3 TS -