Proposed Terminal Building: Archt. Herminiano R. Huelgas
Proposed Terminal Building: Archt. Herminiano R. Huelgas
Proposed Terminal Building: Archt. Herminiano R. Huelgas
OR T T I O N
SP
A
N
N
A
D
T OF TR
A B C D E F
COM M U N
EN
M
IC
RT IO
AT
NS DEPA
PROJECT NAME :
FEMALE MALE
TOILET TOILET OFFICE CONSTRUCTION/RENOVATIONS
OF TOILET FACILITIES
4
LOCATION :
VIGAN AIRPORT
Vigan City, Ilocos Sur , Region I
NTS
NTS
GUILLERMO L. LEONARDO
O.I.C-Assistant Secretary for
Project Management
Approved:
Sheet Content:
A
N
A
N
D
T OF TR
CO M M U N
EN
TM
IC
AT
AR IO N
S DEP
(agency logo)
SEE TO ENGINEER'S DETAIL 82 GALS. CAPACITY
COMMON DEPARTURE & ARRIVAL ROOM PRESSURIZED TANK
(SANITARY) 1 HP WATER PUMP
REPUBLIC OF THE PHILIPPINES
WATER LINE
DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS
PRESSURIZED TANK
PROJECT NAME :
1HP WATER PUMP
OFFICE 20AT CIRCUIT BREAKER
CONSTRUCTION/RENOVATIONS
EXHAUST DUCT OUTLET
CISTERN TANK
OF TOILET FACILITIES FOR CAAP
(CAA. 2. CR. T1. D1. E1. L1. 1. 0..), ( CAA. 2. CR. T1. D1. E1. L1. 2.)
4
EXHAUST DUCT OUTLET
FROM SOURCE LOCATION :
VIGAN AIRPORT
Region I, Vigsn City, Ilocos Sur
PROPOSED TERMINAL PLAN PLAN OF WATER PUMP AND PRESSURE TANK ASSEMBLY Prepared by:
Submitted by:
EDGARDO L. COSTES
Assistant Director General II, ADMS
Recommending Approval:
82 GALS. CAPACITY
PRESSURIZED TANK
GUILLERMO L. LEONARDO
O.I.C-Assistant Secretary for
GV GV
Project Management
1 HP WATER CV
3
GV PUMP 4" DIA. GI PIPE
FROM SOURCE (to toilets)
Approved:
A
N
A
ND
T OF TR
CO M M U N
EN
TM
IC
AT
R IO
N S DE PA
PROJECT NAME :
CONSTRUCTION/RENOVATIONS
2 OF TOILET FACILITIES FOR CAAP
CAA. 2. CR. T1. D1. E1. L1. 1. 0.
COMMON DEPARTURE & ARRIVAL ROOM CAA. 2. CR. T1. D1. E1. L1. 2.
3
LOCATION :
VIGAN AIRPORT
FEMALE MALE Vigan City, Ilocos Sur , Region I
TOILET TOILET OFFICE
TOILET
LEGEND :
Submitted by:
SCALE NTS
EDGARDO L. COSTES
Assistant Director General II,
Aerodrome Development and Management Division
A B C D E F
Recommending Approval:
1 GUILLERMO L. LEONARDO
O.I.C-Assistant Secretary for
Project Management
Sheet No.:
- -
A - TS -
AT IO
4.40m OR T N
SP
A
N
A
N
D
T OF TR
0.20m 0.20m 0.90m 0.20m 0.90m 0.20m
CO M M U N
A B C D E F 1.80m
EN
TM
IC
0.20m
AT
AR IO N
S DEP
1.40m
1.00m
AND COMMUNICATIONS
1 SEWER LINE
0.20m
SEPTIC VAULT
PLAN
(agency logo)
2
3 PROJECT NAME :
0.10m
0.34m
PRESSURIZED TANK CONSTRUCTION/RENOVATIONS
FEMALE MALE
OFFICE
OF TOILET FACILITIES FOR CAAP
0.30m
TOILET TOILET TOILET (CAA. 2. CR. T1. D1. E1. L1. 1. 0..), ( CAA. 2. CR. T1. D1. E1. L1. 2.)
AIR SPACE
AIR SPACE AIR SPACE
WATER LEVEL
CISTERN TANK WATER LEVEL
WATER LEVEL LOCATION :
4
VIGAN AIRPORT
1.00m
FROM SOURCE
Region I, Vigsn City, Ilocos Sur
0.15m
SECTION HERMINIANO R. HUELGAS
Acting Division Chief III
PROPOSED TERMINAL PLAN Infrastructure Development and Design Division
EDGARDO L. COSTES
Assistant Director General II, ADMS
Recommending Approval:
SPECIFICATION:
1. THE LOCATION OF SEPTIC VAULT/ PRESSURIZED TANK SHALL BE MORE THAN 3.0 METERS AWAY FROM GUILLERMO L. LEONARDO
THE BUILDING LINE. 82 GALS. CAPACITY O.I.C-Assistant Secretary for
PRESSURIZED TANK Project Management
2. THE DISTANCE OF SEPTIC VAULT FROM PROPOSED CISTERN SHALL BE 15 METERS AWAY.
3. WATER PIPE LINE AND SEWER LINE RUNNING PARALLEL IN DIRECTION SHALL HAVE A MINIMUM DISTANCE GV GV
IN SEPARATION OF 0.50 METER AND AVOID INSTALLING WATER LINE BELOW SEWER LINE.
1 HP WATER CV
GV PUMP
4. THE STANDARD PLUMBING PLANS (COLD WATER LINE AND SEWER LINE) SHALL RE-CONFIGURATED AND FROM SOURCE MH
3
4" DIA. GI PIPE (to toilets)
5. THE CONSTRUCTION SHALL BE SUPERVISED BY A LICENSE PLUMBER AND SHALL BE COVERED BY NATIONAL (to existing drain)
Sheet Content:
Sheet No.:
1 -
P 3 TS -