Contents table
No Topic
1 Title Page
2 Contents Table
3 Part A – Safety Instructions
5 Part B – Compressor Description
9 Part C - Technical Data
11 Part D – Description of compressor operation
11 Part E – Maintenance
12 Part F - Spare parts table
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
4. Maintenance
4.1 Before removing any compressor service door , stop the compressor and
disconnect the main electric power
4.2 Isolate the compressor from the plant air system by closing the gate valve.
4.3 Before opening the oil cap of the oil receiver / separator verify there is no
pressure in the oil receiver. Open the cap slowly to allow pressure release (if
any)
4.4 Check the oil level daily to avoid heating the compressor due to lake of oil.
after replacing the oil' close and tighten the cup.
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
Remote Control
Settings:
When does Remote
Control, switch must be
connected to DI2 and
COM (Inside the VFD).
Need change parameter of
DI2 to 60 and change
parameter of F0-02 to 1.
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
Performance:
Compression Unit
Model: TRL 126LPMB/75HP; TRL 135LPMB/100HP.
Motor
Type: SINCHRONIC Electric
Power: 75HP/55kW; 100HP/75kW
protection : IP55
Insulation: Grade F
R.P.M : 3100
Hz : 155
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
- LOAD – The compressor is running and supply compressed air to the air
system.
- UNLOAD – The compressor is running but do not supply compressed air .
- STANDBY – The compressor is not running and waiting to restart
automatically when compressed air will be needed.
- The transfer between the three operating modes is controlled by a pressure
switch (pressostat )
- The pressure switch operate the compressor between two working pressure:
P2 – Max allowed working pressure
P1 – Min allowed working pressure
- When the pressure reaches P2 – the p.switch change the working mode to –
"Unload"
- When the pressure reaches P1 – the pressure switch change the working mode
to "Load"
- If at "Unload" More then a set time ( usually 4 minutes) The compressor enter
"Standby" mode, and the white "Standby" light illuminate in the operation switch
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
Part E – Maintenance
1. General
Maintenance must be performed according to the compressor running hours. The purpose of
such maintenance is:
- to insure safe operation
- To insure "free of failures" operation
- To insure long life of the compressor
- To insure stable high performance of the compressor
- Keeping the recommended maintenance schedule will insure long life, high
performance operation.
- 500 working hours after the installation first maintenance operation is required
Note:
- Compressor that works 8 hours' 5 days weekly will work 2000 hours in one year
- It is recommended to perform maintenance at least once a year
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL
* Screw Compressors * Piston Compressors * Dryers
WWW.EL-AV.COMPRESSORS.CO.IL ELCD-MANUAL