pst300 600 70 - CP
pst300 600 70 - CP
pst300 600 70 - CP
Type PST
So
f
Ty tsta
pe rte
PS rs
T
6
6
Description
Wide main voltage range, 200 - 690 VAC
Wide control voltage range, 100 - 250 V,
50/60 Hz
Current ratings 30 to 1050 A (In Line) and
52 - 1800 A (Inside Delta)
Same unit can be used for both In Line and
Inside Delta connection
Premium adjustable Softstarter functions
like start/stop ramp, kick start, jog, step
down voltage and sequential starts
Current limit adjustable between 200% to
500% of motor FLA
6.19
1SXU 000 023 C0201
rs
rte T
a
t
fts PS
So ype
T
General information
Catalog number explanation
Open & enclosed
Open
Control voltage
70 100 - 250 V, 50/60 Hz
Bypass
No digit No integrated bypass
B Integrated bypass
Current rating
UL / IEC
30 28/30
37 34/37
44 42/44
50 54/50
72 68/72
85 80/85
105 104/105
142 130/142
175 156/175
UL
210
250
300
370
470
570
720
840
1050
Line voltage
600 208/230/480/600 V
690 690 V 3
IEC
192/210
248/250
302/300
361/370
480/470
590/570
720/720
840/840
1062/1050
Enclosed
T 100 D F 1 48 D A
Soft starter settings
T Type PST Enclosed
Horsepower
010 10
015 15
020 20
025 25
030 30
040 40
050 50
060 60
075 75
100 100
125
150
200
250
300
350
400
450
500
600
125
150
200
250
300
350
400
450
500
600
800
900
1000
1200
1400
1500
1600
1700
1800
800
900
1000
1200
1400
1500
1600
1700
1800
Connection type
L Inline
D Inside Delta
Combination type
No digit non-combination
F fusible disconnect
B thermal magnetic circuit breaker
M magnetic only breaker
N non-fusible disconnect
Enclosure
1 NEMA 1
2 NEMA 12 2
3 NEMA 3R 2
4 NEMA 4 2
X NEMA 4x stainless steel 2
6.20
1SXU 000 023 C0201
Options 1
A Start-stop pushbutton
B Across the line rated (AC3) contactor with
emergency bypass control
C 2 position selector switch
D 3 position selector switch
E Pilot light
F Start-stop pushbutton and pilot light
H 2 position selector switch and pilot light
J 3 position selector switch and pilot light
M Shunt rated (AC1) bypass contactor
W Isolation contactor
Fuse clip
A 30A, 600V, Class J
B 60A, 600V, Class J
C 100A, 600V, Class J
D 200A, 600V, Class J
E 400A, 600V, Class J
F 600A, 600V, Class J
G 800A, 600V, Class L
H
J
K
L
M
N
E
F
G
H
J
K
L
M
700 N 3000
800
900
1000
1200
1600
2000
2500
400
600
800
1200
Line voltage
20: 208V 120V control voltage
23: 230V 120V control voltage
38: 380V 220V control voltage
41: 415V 220V control voltage
48: 480V 120V control voltage
60: 600V 120V control voltage
Low Voltage Products & Systems
ABB Inc. 888-385-1221 www.abb-control.com
So
f
Ty tsta
pe rte
PS rs
T
General information
Application and description
Programmable
inputs
Programmable
signal relays
Digital key-pad
Display with
plain words in
your language
Clear
information
FieldBus communication
Application
Digital display
The PST range is a microprocessor based softstarter designed with the latest
technology for soft start and soft stop of motors. The PST Softstarter has several
advanced motor protection features as standard. The four button key pad and the
logic structure of the menu makes the installation, commissioning and operation
easy. It is possible to choose between 12 different languages.
Your business is going global. Shouldn't your motor control go global, too? The
PST display gives you information presented in plain words in your language.
You can choose between almost a dozen languages including English, German,
Italian, Chinese, Finnish, Swedish, French, Spanish, Dutch, Russian, Turkish
and Portuguese. On the PST display, you get all the information you need to set
up, adjust and trouble-shoot. This makes the PST extremely easy to handle and
reduces the risk of misinterpretations.
The PST Softstarter can be used with or without a by-pass contactor. The larger
sizes, PSTB370 PSTB1050, include a built-in by-pass contactor.
The PST Softstarter can be selected according to the rated motor power in
normal duty applications like pumps, compressors, elevators, escalators, short
conveyor belts and bow thrusters.
)N ,INE
At any time, you can read output current, output voltage, number of starts, total
run time and motor temperature on the display. If a fault should occur, this is also
indicated on the display. The fault messages are presented in clear text in the
selected language.
)NSIDE $ELTA
!
!
!
!
6.21
1SXU 000 023 C0201
rs
rte T
a
t
fts PS
So ype
T
General information
Application and description
Fieldbus communication
The PST Softstarter has a built-in interface on the front for connection of the ABB
FieldBusPlug used for fieldbus communication. Through this interface, it is possible to control the softstarter, achieve status information, upload and download
parameters. The interface between the softstarter and the FieldBusPlug is always
the same. Independently of PST Softstarter size or delivery date, it is possible
to connect to any fieldbus protocol later on since this is defined in the FieldBusPlug itself. The following protocols are currently available: AS-I, DeviceNet
and Profibus DP. To connect the PST Softstarter to a fieldbus system, you need
the accessories described on pages 6.33 to 6.34 as well as specific software for
PLC set-up, which is available on the ABB web site; see the Resources section
at the bottom of the Softstarter product page at www.abb-control.com/products/
softstarters.htm.
6.22
1SXU 000 023 C0201
So
f
Ty tsta
pe rte
PS rs
T
Open
In-Line, Inside Delta
7.5 1800 HP
Connected In-Line 1
Maximum motor current
PST72-600-70
PST142-600-70
Maximum horsepower
Catalog
number
List
price
IEC
208V
240V
380V
480V
600V
28
34
42
54
68
30
37
44
50
72
7.5
10
10
15
20
10
10
15
20
25
15
20
25
30
40
20
25
30
40
50
25
30
40
50
60
9
9
11
11
22
PST30-600-70
PST37-600-70
PST44-600-70
PST50-600-70
PST72-600-70
80
104
130
85
105
142
25
30
40
30
40
50
50
60
75
60
75
100
75
100
125
22
27
33
PST85-600-70
PST105-600-70
PST142-600-70
2380
2410
3375
156
192
248
302
175
210
250
300
50
60
75
100
60
75
100
100
100
125
150
150
125
150
200
250
150
200
250
300
44
49
49
53
PST175-600-70
PST210-600-70
PST250-600-70
PST300-600-70
3420
3870
4350
4480
361
480
590
720
840
1062
370
470
570
720
840
1050
125
150
200
250
300
400
150
200
250
300
350
450
200
300
350
450
500
600
300
400
500
600
700
900
350
500
600
700
800
1000
84
93
97
119
124
137
PSTB370-600-70
PSTB470-600-70
PSTB570-600-70
PSTB720-600-70
PSTB840-600-70
PSTB1050-600-70
Weight
(lbs.)
$ 1330
1360
1390
1730
1755
5660
7000
8550
9630
10,900
18,000
PST175-600-70
Weight
(lbs.)
UL
Maximum horsepower
Catalog
number
List
price
UL
IEC
208V
240V
380V
480V
600V
42
54
72
80
104
51
64
76
86
124
10
15
20
25
30
15
20
25
30
40
30
40
50
50
75
30
40
50
60
75
40
50
60
75
100
9
9
11
11
22
PST30-600-70
PST37-600-70
PST44-600-70
PST50-600-70
PST72-600-70
130
156
192
148
181
245
40
50
60
50
60
75
75
100
150
100
125
150
125
150
200
22
27
33
PST85-600-70
PST105-600-70
PST142-600-70
2380
2410
3375
248
302
361
480
303
363
433
519
75
100
125
150
100
100
150
200
200
200
250
300
200
250
300
400
250
300
350
500
44
49
49
53
PST175-600-70
PST210-600-70
PST250-600-70
PST300-600-70
3420
3870
4350
4480
590
720
640
814
200
250
250
300
400
500
500
600
600
700
84
93
PSTB370-600-70
PSTB470-600-70
5660
7000
840
1247
1454
1839
987
1247
1454
1818
300
400
500
600
350
500
600
700
600
800
900
1000
700
1000
1200
1500
800
1200
1500
1800
97
119
124
137
PSTB570-600-70
PSTB720-600-70
PSTB840-600-70
PSTB1050-600-70
$ 1330
1360
1390
1730
1755
8550
9630
10,900
18,000
PSTB370-600-70
PSTB570-600-70
1 Different frame sizes are separated by rules.
6.23
1SXU 000 023 C0201
rs
rte T
a
t
fts PS
So ype
T
Enclosed
NEMA 1, 12
In-Line, 5 1000 HP
Connected In-Line
Max. motor current
UL
IEC
208V
Maximum horsepower
240V
380V
480V
600V
NEMA1, 480V
NEMA1, 600V
Catalog
Number
Catalog
Number
NEMA12, 480V
NEMA12, 600V
List
Price
Catalog
Number
Catalog
Number
List
Price
18
18
10
10
15
T010L1-48
T015L1-60
$ 1655
T010L2-48M
T015L2-60M
$ 1905
28
30
7.5
10
15
20
25
T020L1-48
T025L1-60
1655
T020L2-48M
T025L2-60M
1930
34
37
10
10
20
25
30
T025L1-48
T030L1-60
1685
T025L2-48M
T030L2-60M
2085
42
44
10
15
25
30
40
T030L1-48
T040L1-60
1715
T030L2-48M
T040L2-60M
2165
54
50
15
20
30
40
50
T040L1-48
T050L1-60
2055
T040L2-48M
T050L2-60M
2555
68
72
20
25
40
50
60
T050L1-48
T060L1-60
2080
T050L2-48M
T060L2-60M
2630
80
85
25
30
50
60
75
T060L1-48
T075L1-60
2705
T060L2-48M
T075L2-60M
3355
104
105
30
40
60
75
100
T075L1-48
T100L1-60
2735
T075L2-48M
T100L2-60M
3460
130
142
40
50
75
100
125
T100L1-48
T125L1-60
3875
T100L2-48M
T125L2-60M
4775
156
175
50
60
100
125
150
T125L1-48
T150L1-60
3920
T125L2-48M
T150L2-60M
5170
192
210
60
75
125
150
200
T150L1-48
T200L1-60
4370
T150L2-48M
T200L2-60M
5770
248
250
75
100
150
200
250
T200L1-48
T250L1-60
4850
T200L2-48M
T250L2-60M
6550
302
300
100
100
150
250
300
T250L1-48
T300L1-60
5080
T250L2-48M
T300L2-60M
7830
361
370
125
150
200
300
350
T300L1-48M1
T350L1-60M1
6260
T300L2-48M1
T350L2-60M1
6910
414
400
250
350
400
T350L1-48M1
T400L1-60M1
7700
T350L2-48M1
T400L2-60M1
8450
480
470
150
200
300
400
500
T400L1-48M1
T500L1-60M1
7700
T400L2-48M1
T500L2-60M1
8550
590
570
200
250
350
500
600
T500L1-48M1
T600L1-60M1
9350
T500L2-48M1
T600L2-60M1
10,350
720
720
250
300
450
600
700
T600L1-48M1
T700L1-60M1
10,830
T600L2-48M1
T700L2-60M1
11,830
840
840
300
350
500
700
800
T700L1-48M1
T800L1-60M1
12,900
T700L2-48M1
T800L2-60M1
14,000
960
350
400
800
900
T800L1-48M1
T900L1-60M1
21,000
T800L2-48M1
T900L2-60M1
22,300
1062
1050
400
450
600
900
1000
T900L1-48M1
21,000
T1000L1-60M1
T900L2-48M1
22,300
T1000L2-60M1
1 Includes integrated shunt rated (AC1) bypass contactor as standard. For across the line rated (AC3) bypass contactors, see page 6.30.
6.24
1SXU 000 023 C0201
So
f
Ty tsta
pe rte
PS rs
T
Enclosed
NEMA 1, 12
Inside Delta, 7.5 1800 HP
Connected Inside Delta
Max. motor current
UL
IEC
208V
Maximum horsepower
240V
380V
480V
600V
NEMA1, 480V
NEMA1, 600V
Catalog
Number
Catalog
Number
NEMA12, 480V
NEMA12, 600V
List
Price
Catalog
Number
Catalog
Number
List
Price
28
30
7.5
10
15
20
25
T020D1-48
T025D1-60
$ 1655
T020D2-48M
T025D2-60M
$ 1905
34
37
10
10
20
25
30
T025D1-48
T030D1-60
1655
T025D2-48M
T030D2-60M
1905
42
44
10
15
25
30
40
T030D1-48
T040D1-60
1655
T030D2-48M
T040D2-60M
1930
54
50
15
20
30
40
50
T040D1-48
T050D1-60
1685
T040D2-48M
T050D2-60M
2085
68
72
20
25
40
50
60
T050D1-48
T060D1-60
1715
T050D2-48M
T060D2-60M
2165
80
85
25
30
50
60
75
T060D1-48
T075D1-60
2055
T060D2-48M
T075D2-60M
2555
104
105
30
40
60
75
100
T075D1-48
T100D1-60
2080
T075D2-48M
T100D2-60M
2630
130
142
40
50
75
100
125
T100D1-48
T125D1-60
2705
T100D2-48M
T125D2-60M
3355
156
175
50
60
100
125
150
T125D1-48
T150D1-60
2735
T125D2-48M
T150D2-60M
3460
192
210
60
75
125
150
200
T150D1-48
T200D1-60
3875
T150D2-48M
T200D2-60M
4775
248
250
75
100
150
200
250
T200D1-48
T250D1-60
3920
T200D2-48M
T250D2-60M
5120
302
300
100
100
150
250
300
T250D1-48
T300D1-60
4370
T250D2-48M
T300D2-60M
5770
361
370
125
150
200
300
350
T300D1-48
T350D1-60
4850
T300D2-48M
T350D2-60M
6550
414
400
250
350
400
T350D1-48
T400D1-60
5080
T350D2-48M
T400D2-60M
7830
480
470
150
200
300
400
500
T400D1-48
T500D1-60
5080
T400D2-48M
T500D2-60M
7830
590
570
200
250
350
500
600
T500D1-48M1
T600D1-60M1
6260
T500D2-48M1
T600D2-60M1
6910
720
720
250
300
450
600
700
T600D1-48M1
T700D1-60M1
7700
T600D2-48M1
T700D2-60M1
8550
840
840
300
350
500
700
800
T700D1-48M1
T800D1-60M1
9350
T700D2-48M1
T800D2-60M1
10,350
960
350
400
800
900
T800D1-48M1
10,830
T900D1-60M1
T800D2-48M1
T900D2-60M1
12,130
1062
1050
400
450
600
900
1000
T900D1-48M1
10,830
T1000D1-60M1
T900D2-48M1
T1000D2-60M1
12,130
1247
1215
400
500
800
1000
1200
T1000D1-48M1
10,830
T1200D1-60M1
T1000D2-48M1
T1200D2-60M1
12,130
1454
1370
500
600
900
1200
1500
T1200D1-48M1
12,900
T1500D1-60M1
T1200D2-48M1
T1500D2-60M1
14,650
1839
1823
600
700
1200
1500
1800
T1500D1-48M1
21,000
T1800D1-60M1
T1500D2-48M1
T1800D2-60M1
22,750
1 Includes integrated shunt rated (AC1) bypass contactor as standard. For across the line rated (AC3) bypass contactors, see page 6.30.
6.25
1SXU 000 023 C0201
rs
rte T
a
t
fts PS
So ype
T
Enclosed
NEMA 1, Combination
In-Line, 5 1000 HP
Connected In-Line
Max. motor current
UL
IEC
208V
Maximum horsepower
240V
380V
480V
600V
NEMA1, 480V
Circuit breaker
NEMA1, 600V
Circuit breaker
Catalog
Number
Catalog
Number
List
Price
NEMA1, 480V
Fused disconnect
NEMA 1, 600V
Fused disconnect
Catalog
Number
Catalog
Number
List
Price
18
18
10
10
15
T010LB1-48E
T015LB1-60E
$ 2055
T010LF1-48A
T015LF1-60A
$ 2055
28
30
7.5
10
15
20
25
T020LB1-48J
T025LB1-60J
2065
T020LF1-48B
T025LF1-60B
2065
34
37
10
10
20
25
30
T025LB1-48K
T030LB1-60K
2110
T025LF1-48B
T030LF1-60B
2110
42
44
10
15
25
30
40
T030LB1-48L
T040LB1-60L
2315
T030LF1-48C
T040LF1-60C
2315
54
50
15
20
30
40
50
T040LB1-48N
T050LB1-60N
2655
T040LF1-48C
T050LF1-60C
2655
68
72
20
25
40
50
60
T050LB1-48R
T060LB1-60R
2680
T050LF1-48C
T060LF1-60C
2680
80
85
25
30
50
60
75
T060LB1-48S
T075LB1-60S
3705
T060LF1-48D
T075LF1-60D
3705
104
105
30
40
60
75
100
T075LB1-48T
T100LB1-60T
3735
T075LF1-48D
T100LF1-60D
3735
130
142
40
50
75
100
125
T100LB1-48V
T125LB1-60V
5075
T100LF1-48D
T125LF1-60D
5075
156
175
50
60
100
125
150
T125LB1-48X
T150LB1-60X
5720
T125LF1-48E
T150LF1-60E
5720
192
210
60
75
125
150
200
T150LB1-48Y
T200LB1-60Y
6170
T150LF1-48E
T200LF1-60E
6170
248
250
75
100
150
200
250
T200LB1-48A
T250LB1-60Z
6650
T200LF1-48E
T250LF1-60E
6650
302
300
100
100
150
250
300
T250LB1-48B
T300LB1-60B
7580
T250LF1-48F
T300LF1-60F
7580
361
370
125
150
200
300
350
T300LB1-48DM1
T350LB1-60CM1
8860
T300LF1-48FM1
T350LF1-60FM1
8860
414
400
250
350
400
T350LB1-48EM1
T400LB1-60DM1
11,300
T350LF1-48FM1
T400LF1-60FM1
11,300
480
470
150
200
300
400
500
T400LB1-48FM1
T500LB1-60EM1
11,800
T400LF1-48GM1
T500LF1-60GM1
11,800
590
570
200
250
350
500
600
T500LB1-48GM1
14,550
T600LB1-60GM1
T500LF1-48HM1
T600LF1-60H1
14,550
720
720
250
300
450
600
700
T600LB1-48JM1
T700LB1-60JM1
16,030
T600LF1-48HM1
T700LF1-60H1
16,030
840
840
300
350
500
700
800
T700LB1-48KM1
T800LB1-60JM1
19,400
T700LF1-48JM1
T800LF1-60J1
19,400
960
350
400
800
900
T800LB1-48KM1
T900LB1-60KM1
27,500
T800LF1-48JM1
T900LF1-60J1
27,500
1062
1050
400
450
600
900
1000
T900LB1-48KM1
T1000LB1-60KM1
28,200
T900LF1-48KM1
T1000LF1-60K1
28,200
1 Includes integrated shunt rated (AC1) bypass contactor as standard. For across the line rated (AC3) bypass contactors, see page 6.30.
6.26
1SXU 000 023 C0201
So
f
Ty tsta
pe rte
PS rs
T
Enclosed
NEMA 1, Combination
Inside Delta, 7.5 1900 HP
Connected Inside Delta
Max. motor current
Maximum horsepower
NEMA1, 480V
Circuit breaker
NEMA1, 600V
Circuit breaker
Catalog
Number
Catalog
Number
NEMA1, 480V
Fused disconnect
List
Price
Catalog
Number
NEMA 1, 600V
Fused disconnect
Catalog
Number
List
Price
UL
IEC
208V
240V
380V
480V
600V
28
30
7.5
10
15
20
25
T020DB1-48J
T025DB1-60J
$ 2065
T020DF1-48B
T025DF1-60B
$ 2065
34
37
10
10
20
25
30
T025DB1-48K
T030DB1-60K
2080
T025DF1-48B
T030DF1-60B
2080
42
44
10
15
25
30
40
T030DB1-48L
T040DB1-60L
2255
T030DF1-48C
T040DF1-60C
2255
54
50
15
20
30
40
50
T040DB1-48N
T050DB1-60N
2285
T040DF1-48C
T050DF1-60C
2285
68
72
20
25
40
50
60
T050DB1-48R
T060DB1-60R
2315
T050DF1-48C
T060DF1-60C
2315
80
85
25
30
50
60
75
T060DB1-48S
T075DB1-60S
3055
T060DF1-48D
T075DF1-60D
3055
104
105
30
40
60
75
100
T075DB1-48T
T100DB1-60T
3080
T075DF1-48D
T100DF1-60D
3080
130
142
40
50
75
100
125
T100DB1-48V
T125DB1-60V
3905
T100DF1-48D
T125DF1-60D
3905
156
175
50
60
100
125
150
T125DB1-48X
T150DB1-60X
4535
T125DF1-48E
T150DF1-60E
4535
192
210
60
75
125
150
200
T150DB1-48Y
T200DB1-60Y
5675
T150DF1-48E
T200DF1-60E
5675
248
250
75
100
150
200
250
T200DB1-48A
T250DB1-60Z
5720
T200DF1-48E
T250DF1-60E
5720
302
300
100
100
150
250
300
T250DB1-48B
T300DB1-60B
6870
T250DF1-48F
T300DF1-60F
6870
361
370
125
150
200
300
350
T300DB1-48D
T350DB1-60C
7450
T300DF1-48F
T350DF1-60F
7450
414
400
250
350
400
T350DB1-48E
T400DB1-60D
8680
T350DF1-48F
T400DF1-60F
8680
480
470
150
200
300
400
500
T400DB1-48F
T500DB1-60E
9180
T400DF1-48G
T500DF1-60G
9180
590
570
200
250
350
500
600
T500DB1-48GM1
11,460
T600DB1-60GM1
T500DF1-48HM1
T600DF1-60HM1
11,460
720
720
250
300
450
600
700
T600DB1-48JM1
T700DB1-60JM1
12,900
T600DF1-48HM1
T700DF1-60HM1
12,900
840
840
300
350
500
700
800
T700DB1-48KM1
T800DB1-60JM1
15,850
T700DF1-48JM1
T800DF1-60JM1
15,850
960
350
400
800
900
T800DB1-48KM1
T900DB1-60KM1
17,330
T800DF1-48JM1
T900DF1-60JM1
17,330
1062
1050
400
450
600
900
1000
T900DB1-48KM1
T1000DB1-60KM1
18,030
T900DF1-48KM1
T1000DF1-60KM1
18,030
1247
1215
400
500
800
1000
1200
T1000DB1-48LM1
T1200DB1-60LM1
20,830
T1000DF1-48KM1
T1200DF1-60KM1
20,830
1454
1370
500
600
900
1200
1500
T1200DB1-48MM1
22,900
T1500DB1-60MM1
T1200DF1-48LM1
T1500DF1-60LM1
22,900
1839
1823
600
700
1200
1500
1800
T1500DB1-48NM1
T1800DB1-60NM1
T1500DF1-48NM1
T1800DF1-60NM1
33,500
33,500
1 Includes integrated shunt rated (AC1) bypass contactor as standard. For across the line rated (AC3) bypass contactors, see page 6.30.
6.27
1SXU 000 023 C0201