Single Aisle Technical Training Manual Maintenance Course - M35 Line Mechanics (V2500-A5/ME) Lights
Single Aisle Technical Training Manual Maintenance Course - M35 Line Mechanics (V2500-A5/ME) Lights
Single Aisle Technical Training Manual Maintenance Course - M35 Line Mechanics (V2500-A5/ME) Lights
SINGLE AISLE
TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS
(V2500-A5/ME)
LIGHTS
This document must be used for training purposes only
LIGHTS
COCKPIT
Cockpit Annunciator Light Test & Dimming D/O (3) . . . . . . . . . . . . . 2
CABIN
Cabin Lights System Description (3) . . . . . . . . . . . . . . . . . . . . . . . . . 12
CABIN (Classic)
FAP Cabin Lighting Page (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
CABIN (Enhanced)
FAP Cabin Lighting Page (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
EMERGENCY LIGHTS (Classic)
Emergency Lights Test (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
U3U06191 - U0O35M0
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) TABLE OF CONTENTS May 11, 2006
33 - LIGHTS Page 1
SINGLE AISLE TECHNICAL TRAINING MANUAL
The secondary winding of each transformer has: - 3 are related to the ANN LTs supplied by the AC2 generation,
- 7 outputs of 5 VAC each mounted in parallel; each one is protected - 7 are related to the ANN LTs supplied by the ESS generation.
by a delayed action fuse set at 4 A, Each board comprises:
- 2 outputs of 6.3 V each protected by the same type of fuse. - 2 relays supplied by busbar 206PP with 28 VDC through circuit
The primary winding of each transformer has two inputs to get the breaker 30LP located on the rear circuit breaker panel 122VU. These
correct dimming level (DIMmed position). 2 relays are used for the ANN LT tests when the switch 33LP is in
If the 115 V supply is switched over to either input we obtain at the the TEST position,
secondary winding: - 10 relays supplied by the various A/C systems with 28 VDC. They
- the 5 VAC (BRighT position) or 3 VAC (DIM position), supply the ANN LT with 5 VAC whereas the system data are supplied
- the 6.3 VAC (BRT position) or 4.3 VAC (DIM position) for rectified with 28 VDC
voltages.
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 2
SINGLE AISLE TECHNICAL TRAINING MANUAL
FOUR-STAGES RELAY
They are located in the relay box 103VU. They are used for the test
of the equipment annunciator lights (high intensity) or of other
annunciator lights (ON - OFF). The busbar 206PP supplies 28 VDC
to the coil of these relays through the circuit breaker 30LP located on
the rear circuit breaker panel 122VU
U3U06191 - U0O35M0 - UM33D3000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 3
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33D3000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 4
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 5
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 6
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33D3000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 7
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 8
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33D3000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 9
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 10
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33D3000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) COCKPIT ANNUNCIATOR LIGHT TEST & DIMMING D/O (3) May 10, 2006
33 - LIGHTS Page 11
SINGLE AISLE TECHNICAL TRAINING MANUAL
ENTRY LIGHTS
The related DEUs control the entry fluorescent lamps according to the
FAP selection. The FAP controls the DEUs via the CIDS DIRs in order
to give BRT levels (100%, 50% or 10%).
U3U06191 - U0O35M0 - UM33D1000000001
NOTE: If the engines are running and the cockpit door is open, the
CIDS directors signal the DEU of the left forward entry light
to set the intensity to 10%.
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) CABIN LIGHTS SYSTEM DESCRIPTION (3) May 10, 2006
33 - LIGHTS Page 12
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33D1000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) CABIN LIGHTS SYSTEM DESCRIPTION (3) May 10, 2006
33 - LIGHTS Page 13
SINGLE AISLE TECHNICAL TRAINING MANUAL
NOTE: Note: The Mean Time Between Failure (MTBF) of LED reading
lights is 100,000 flight hours. Thus, there is no replacement
procedure apart from replacing the complete light assembly.
Cabin signs must be replaced if three or more LEDs have failed
U3U06191 - U0O35M0 - UM33D1000000001
(de-graded performance).
If a full failure of the FAP and/or CIDS occurs or cabin
decompression occurs, the entrance lighting comes on
automatically to 100% BRT level.
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) CABIN LIGHTS SYSTEM DESCRIPTION (3) May 10, 2006
33 - LIGHTS Page 14
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33D1000000001
CIDS ENHANCED
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) CABIN LIGHTS SYSTEM DESCRIPTION (3) May 10, 2006
33 - LIGHTS Page 15
SINGLE AISLE TECHNICAL TRAINING MANUAL
CABIN LIGHTING
The cabin light panel comprises control keys for the various cabin lights.
There are controls for the entrance areas and the different cabin sections.
The MAIN ON key when pushed, switches on the cabin zones and
entrance areas lighting with 100% intensity, and contrary the MAIN OFF
key when pushed, switches off the cabin zones and entrance areas lighting.
The BRighTness, DIMming 1 and DIM2 keys respectively switch on the
lights at 100%, 50% and 10% intensity, for the FWD, after and middle
(only for A321) entrance areas. In addition, POWER LAVatory,
ATTeNdant and READing keys provide the supply respectively for the
lavatory lights, attendant work lights and the passenger reading lights.
U3U06191 - U0O35M0 - UM33P1000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) FAP CABIN LIGHTING PAGE (3) May 10, 2006
33 - LIGHTS Page 16
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33P1000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) FAP CABIN LIGHTING PAGE (3) May 10, 2006
33 - LIGHTS Page 17
SINGLE AISLE TECHNICAL TRAINING MANUAL
controls and displays are available with three levels of lighting, BRT,
DIM1 and DIM2. The Main On/Off key is used to switch ON/OFF cabin
zone and entrance areas lighting with 100% intensity, this function is
only available on ground. The AISLE key is used to switch ON/OFF the
ceiling lighting, and the WinDOw key to switch ON/OFF the windows
lighting. Additional functions are Reading/Light Set (on) and R/L Reset
(off). An automatic DIM of the FWD entrance area is activated if the
cockpit door is opened and the engines are running. In case of cabin
decompression, the passenger compartment lighting automatically
switches to full brightness (100%).
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) FAP CABIN LIGHTING PAGE (3) May 10, 2006
33 - LIGHTS Page 18
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33P1000000002
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) FAP CABIN LIGHTING PAGE (3) May 10, 2006
33 - LIGHTS Page 19
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) FAP CABIN LIGHTING PAGE (3) May 10, 2006
33 - LIGHTS Page 20
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33P1000000002
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) FAP CABIN LIGHTING PAGE (3) May 10, 2006
33 - LIGHTS Page 21
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 23
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33Y2000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 24
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 25
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 26
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33Y2000000001
EPSU TEST
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 27
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 28
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33Y2000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 29
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 30
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3U06191 - U0O35M0 - UM33Y2000000001
MAINTENANCE COURSE - M35 LINE MECHANICS (V2500-A5/ME) EMERGENCY LIGHTS TEST (3) May 10, 2006
33 - LIGHTS Page 31
AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE U3U06191
MAY 2006
PRINTED IN FRANCE
AIRBUS S.A.S. 2006
ALL RIGHTS RESERVED