Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Plastic Skylights

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 5

Specifications

SECTION 07810 – PLASTIC UNIT SKYLIGHTS

PART 1 – GENERAL 07810-2/5


1.1 SECTION INCLUDES 07810-2/5
1.2 REFERENCES 07810-2/5
1.3 SUBMITTALS 07810-3/5
1.4 WARRANTY 07810-3/5

PART 2 - PRODUCTS 07810-3/5


2.1 MATERIALS 07810-3/5
2.2 PLASTIC SKYLIGHT UNITS 07810-4/5
2.3 FABRICATION 07810-5/5
2.4 FACTORY FINISHING 07810-5/5

PART 3 - EXECUTION 07810-5/5


3.1 INSTALLATION 07810-5/5

PLASTIC UNIT SKYLIGHT 07810-1/5


Specifications (New Section by ZFP)

SECTION 07810 - PLASTIC UNIT SKYLIGHTS

1. PART 1 - GENERAL

1.1 SECTION INCLUDES

A. Plastic unit skylights with integral insulated curb.

1.2 REFERENCES

A. SAUDI ARABIAN STANDARDS ORGANIZATION (SASO)

SASO 79 Aluminum and aluminum alloys products for architectural


application Part 1: Sheets, strips, bars and structural sections.

SASO 80 Testing methods for aluminum and aluminum alloys products


for building purposes Part 1: Sheets, strips, bars and structural sections.

B. AAMA - American Architectural Manufacturer Association

AAMA-603.8 - Pigmented Organic Coating on Extruded Aluminum.

AAMA-605.2 - High Performance Organic Coatings on Architectural


Extrusions and Panels

AAMA-606.1 - Color Anodic Finishes for Architectural Aluminum

AAMA-607.1 - Clear Anodic Finishes for Architectural Aluminum

C. ASTM - American Society of Testing and Materials:

ASTM B 209 - Aluminum and Aluminum-Alloy Sheet and Plate

ASTM B 221 - Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes and


Tubes

ASTM C 920 - Specifications for Elastomeric Joint Sealants

ASTM D 256 - Test Method for Impact Resistance of Plastics and Electrical
Insulating materials

ASTM D 635 - Test Method for Rate of Burning and/or Extent and Time of
Burning of Self-Supporting Plastics in Horizontal Position

ASTM D 1929 - Test Method for Ignition Properties of Plastics

ASTM 2843 - Test Method for Density of Smoke from the Burning o
Decomposition of Plastics

PLASTIC UNIT SKYLIGHT 07810-2/5


Specifications (New Section by ZFP)

ASTM D 4586 - Specification for Asphalt Roof Cement, Asbestos Free

ASTM D 4802 - Specifications for Poly(Methyl Methacrylate) Acrylic


Plastic Sheet

D. NAAMM - National Association of Architectural Metal Manufacturers

NAAMM - Metal Finishes Manual: For Architectural and Metal Products

E. National Roofing Contractors Association

The NRCA Roofing and Waterproofing Manual

F. Steel Structures Painting Council

SSPC Paint System # 12: Cold-Applied Asphalt Mastic (Extra Thick Film)

1.3 SUBMITTALS

A. Product Data: Provide configurations, dimensions of individual components,


elevations, plans, sections, finishes, profile, including characteristics of light
admitted, transparency, and insulation value of unit.

B. Shop Drawings: Indicating fabrication and installation of skylights, including,


locations, fastening methods, construction and installation details.

C. Samples for initial selection purposes showing manufacturer's full range of


color available for each type of skylight glazing, retainers, frame and curb.

D. Submit manufacturer's installation instructions and recommendations.

1.4 WARRANTY

A. Provide 5 years manufacturer's warranty including coverage of weather and


water tightness of skylight assembly and seal with roofing system.

2. PART 2 - PRODUCTS

2.1 MATERIALS

A. Aluminum Sheets: ASTM B 209 for Aluminum and Aluminum-Alloy 3005-


H25 and temper as required to suit forming operations and finish
requirements.

B. Extruded Aluminum: ASTM B 221, alloy 6063-T52 or alloy and temper as


required to suit forming operations and finish requirements.

PLASTIC UNIT SKYLIGHT 07810-3/5


Specifications (New Section by ZFP)

C. Plastic Sheets: Monolithic, formable, transparent or tinted with good weather


and impact resistance.

1. Polycarbonate: Thermoformable, monolithic polycarbonate sheets


manufactured by the extrusion process, UV-resistant, with average
impact strength of 638 to 850J/m of width when tested according to
ASTM D 256.

D. Fasteners: Same metal as metal being fastened, or non-magnetic stainless


steel or other non-corrosive metal as recommended by manufacturer.

E. Bituminous Coating: SSPC-Paint #12, solvent type, bituminous mastic,


nominally free of sulphur and contains no asbestos fibers, compounded for
0.4 mm dry film thickness per coating.

F. Mastic Sealant: Pollyisobutylene; non-hardening, non-shrinking, non-drying,


non-migrating sealant.

G. Elastomeric Sealant: Generic type recommended by unit manufacturer and


compatible with joint surfaces. ASTM C 920, Type S; Grade NS; Class 25
and Uses NT, G,A (and as applicable to joint substrates indicated) O.

H. Roofing Cement: ASTM D 4586, non-asbestos-fibrated, asphalt cement


designed for trowel application or other adhesive compatible with roofing
system.

2.2 PLASTIC SKYLIGHT UNITS

A. General: Factory-assembled unit consisting of plastic glazing, extruded


aluminum glazing retainer, gasketing, inner frame designed to mount on
separate curb and self-contained flashing.

B. Condensation Control: Fabricated skylight units with integral internal gutters


and non-clogging weeps to collect and dispose condensation.

C. Thermal Break: Fabricated skylight units with thermal barrier separating


interior metal frame from materials exposed to outside temperature.

D. Shape and Size: Pyramidal unless otherwise shown on Drawings.

E. Glazing: Insulated Thermoformed Polycarbonate.

1. Sheet Thickness: Provide double glazed plastic sheet with thickness


required for 1.9 kPa positive (external) loading and 0.95 kPa negative
or uplift (internal) loading as recommended by skylight manufacturer
for unit size and shape.

2. Profile: As indicated on Drawings.

PLASTIC UNIT SKYLIGHT 07810-4/5


Specifications (New Section by ZFP)

3. Glazing Color: Tinted for the outside and transparent for the inside;
color of tint shall be as approved by the Contracting Officer.

4. Glazing Gasket: Manufacturer standard glazing system of EPDM or


neoprene gasket.

2.3 FABRICATION

A. Fabricate free of visual distortion and defects.

B. Provide for removal of condensation.

C. Provide weathertight assembly.

D. Fabricate to drain water entering joints, or migrating moisture occurring


within unit, to exterior.

2.4 FACTORY FINISHING

A. Aluminum: Color-anodized finish, as selected by the Contracting Officer


from the manufacturer standard product range of finishes.

3. PART 3 - EXECUTION

3.1 INSTALLATION

A. Install in accordance with manufacturer's instructions.

B. Coordinate with installation of roofing system and related flashing.

C. Apply bituminous paint on aluminum surfaces of units in contact with


cementitious materials or dissimilar metals.

D. Provide weathertight installation.

END OF SECTION

PLASTIC UNIT SKYLIGHT 07810-5/5