CL COLUMN CL COLUMN COLUMN CL

CONSTRUCTION NOTES
A. GENERAL LC L1 L2

1. CONSTRUCTION NOTES AND TYPICAL ANCHORAGE LENGTH) UNLESS 0.75LC OR 0.3L1 0.3L1 OR 0.75LC (S1) S2 0.3L1 OR .3L2 (S3) 0.3L1 OR 0.75LC (S1) SPLICE ZONE FOR 0.3L2 (S3)
DETAILS APPLY TO ALL DRAWINGS OTHERWISE SHOWN ON DRAWINGS, GIRDER TOP BARS
UNLESS OTHERWISE SHOWN OR SPLICES SHALL BE STAGGERED SPLICE LENGTH SPLICE LENGTH
NOTED. MODIFY TYPICAL DETAILS AS WHENEVER POSSIBLE. CONTINUOUS SEE TABLE CONTINUOUS SEE TABLE CONTINUOUS
TOP BARS TOP BARS WEB BARS
DIRECTED TO MEET SPECIAL 7. ALL ANCHOR BOLTS, DOWELS, AND EQ. EQ. EQ. EQ.

CONDITIONS. OTHER INSERTS SHALL BE PROPERLY TOP BARS AT EXTRA TOP BARS EXTRA TOP BARS EXTRA TOP BARS
2. SHOP DRAWINGS WITH ERECTION AND POSITIONED AND SECURED IN PLACE CANTILEVER'S AT SUPPORT AT SUPPORT AT SUPPORT
DISCONTINUOUS END
PLACING DIAGRAMS OF ALL PRIOR TO PLACING OF CONCRETE.
STRUCTURAL STEEL, MISCELLANEOUS 8. CONTRACTOR SHALL NOTE AND
IRON, PRE-CAST CONCRETE ETC. PROVIDE ALL MISCELLANEOUS

D
SHALL BE SUBMITTED FOR ENGINEER'S CURBS, SILLS, STOOLS, EQUIPMENT,
APPROVAL BEFORE FABRICATION. AND MECHANICAL DRAWINGS.
3. CONTRACTOR SHALL VERIFY ALL 9. ALL CONCRETE SHALL BE KEPT MOIST EXTRA BOTTOMBARS 2D EQ. EQ.
CONTINUOUS
2D EQ. EQ.
CONTINUOUS
AT SUPPORT NO SPLICE NO SPLICE
DIMENSIONS BEFORE ALL WORK IS TO FOR A MINIMUM OF SEVEN (7) BOTTOM BARS BOTTOM BARS
BEGIN, CHECK WITH MECHANICAL CONSECUTIVE DAYS IMMEDIATELY BOTTOM BARS AT 0.125L1 0.125L1 0.125L2 0.125L2
AND ELECTRICAL CONTRACTORS FOR AFTER POURING BY THE USE OF WET CANTILEVER'S EXTRA BOTTOMBARS EXTRA BOTTOMBARS
DISCONTINUOUS END
CONDUITS, PIPE SLEEVES, ETC. TO BE BURLAP, FOG SPRAYING, CURING 50MM MAX. AT MIDSPAN AT MIDSPAN
AT SUPPORT
EMBEDDED IN CONCRETE. COMPOUNDS OR OTHER APPROVED
4. IT SHALL BE THE CONTRACTOR'S METHODS.
HOOP REINFORCEMENT HOOP REINFORCEMENT HOOP REINFORCEMENT
RESPONSIBILITY TO PROVIDE 10. STRIPPING OF FORMS AND SHORES: SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE
ADEQUATE SHORING AND BRACING
Foundations 24 hours
OF THE STRUCTURE FOR ALL LOADS DISCONTINUOUS CONTINUOUS CONTINUOUS
Suspended Slab except when DISCONTINUOUS
THAT MAYBE IMPOSED DURING additional loads are imposed
8 days FREE END END END
END
"1" OR "J" "1" OR "J"
CONSTRUCTION. Walls 18 hours (SEE REMARKS) (SEE REMARKS)

B. CONCRETE REINFORCEMENT Beams 14 days


FOR SIZE AND SPACING OF
1. ALL MATERIALS AND WORKMANSHIP STIRRUPS, SEE REINFORCED
E. MASONRY CONCRETE BLOCKS CONCRETE BEAM SCHEDULE
SHALL CONFIRM WITH THE LATEST C. CAMBER REQUIREMENTS
CL EXTERIOR SUPPORT CL INTERIOR SUPPORT CL INTERIOR SUPPORT
BUILDING CODE OF AMERICAN
CONCRETE INSTITUTE (ACI-318).
1. UNLESS OTHERWISE NOTED ON THE
PLANS OR SPECIFICATIONS, CAMBER
1. ALL NON-LOAD BEARING TYPE CONCRETE
BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO TOP BAR
A TOP BAR
2. ALL CONCRETE SHALL DEVELOP A ALL R.C. BEAMS AT LEAST 10 MM EXCEED 80 PCF. FOR LOAD BEARING TYPE L/4 SPLICE ZONE L/4 L/4 SPLICE ZONE L/4 L/4

MINIMUM COMPRESSIVE STRENGTH AT FOR EVERY 4000 MM OF CLEAR CONCRETE BLOCKS, A MINIMUM
EXTRA CONTINUOUS EXTRA
THE END OF TWENTY-EIGHTY (28) DAYS SPAN EXCEPT CANTILEVERS WHICH COMPRESSIVE STRENGTH OF 8.28 MPA (1200 TOP BARS TOP BARS TOP BARS TOP BARS TOP BARS
WITH CORRESPONDING MAXIMUM SHALL BE 50 MM FOR EVERY 3000 PSI) SHALL BE DEVELOPED.
SIZE AGGREGATE AND SLUMPS AS MM OF CLEAR SPAN. 2. PROVIDE 1 - Ø 16 EXTRA VERTICAL BARS AT
FOLLOWS: 2. UNLESS OTHERWISE NOTED IN PLANS CORNERS, INTERSECTIONS, END OF WALLS,

D
28 DAYS MAX. SIZE OR SPECIFICATIONS, CAMBER ALL AND EACH SIDE OF OPENINGS AS SHOWN.
LOCATION MAX. SLUMP R.C. BEAMS 8 MM PER 3000 MM OF 3. LINTEL BEAMS OR LINTEL BLOCKS SHALL BEAR
STRENGTH AGGREGATE L/5 L/5 L/5 L/5 L/5
Curbs & Slab On SHORTER SPAN AND 14 MM FOR AT LEAST 8 INCHES (200 MM) ON EACH SIDE EXTRA EXTRA CONTINUOUS
3000 psi 1 in. (25 mm) 4 in. (100 mm) BOTTOM BARS BOTTOM BARS BOTTOM BARS
Grade EVERY 2000 MM OF SLABS OF MASONRY WALL OPENING. CONTINUOUS
BOTTOM BARS BOTTOM BAR BOTTOM BAR WEB BARS(TYP)
Foundation 4000 psi 3/4 in. (19 mm) 6 in. (150 mm) CANTILEVER SPAN. 4. 4. WALL REINFORCEMENTS SHALL BE AS L SPLICE ZONE L SPLICE ZONE L
SEE SCHEDULE
Column Foundation
FOLLOWS: TYPICAL BEAM
TYPICAL CONCRETE FOR SIZE AND
4000 psi 3/4 in. (19 mm) 6 in. (150 mm) COLUMN OR BEAM NUMER
to Roof D. FOUNDATION EXTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT
VERTICAL HORIZONTAL DISCONTINUOUS END CONTINUOUS END CONTINUOUS END
Suspended Slabs / 1. FOUNDATION IS DESIGNED USING WALL THICKNESS
4000 psi 3/4 in. (19 mm) 6 in. (150 mm)
Beams ALLOWABLE SOIL BEARING REINFORCEMENT REINFORCEMENT

A
CAPACITY OF 2000 PSF (100 KPA) AS 8 in. (200 mm) 12 Ø @ 600 mmØ 10 Ø @ 600 mm
TYPICAL BEAM DETAILS
3. ALL REINFORCING BARS SHALL PER CLIENT. NOT TO SCALE
CONFORM TO ASTM A615 GRADE 40 2. FOUNDATION SHALL REST ON 6 in. (150 mm) 10 Ø @ 600 mmØ 10 Ø @ 600 mm
FOR DIAMETER 12 AND SMALLER BARS NATURAL SOIL. UNLESS OTHERWISE
AND GRADE 40 FOR DIAMETER 16 NOTED BY THE ENGINEER, NO PART 4 in. (100 mm) 10 Ø @ 600 mmØ 10 Ø @ 600 mm
AND LARGER BARS. OF THE FOUNDATION SHALL REST ON SECTION A CL CONCRETE BEAM 135
°
4. IN GENERAL, THE LATEST EDITION OF FILL.
TOP BARS

6d
ACI-315, MANUAL OF STANDARD 3. THE CONTRACTOR SHALL NOTIFY THE
STRUCTURAL NOTES

b
PRACTICE DETAILING REINFORCED ENGINEER AFTER FOOTING ADDITIONAL ROW OF
CONCRETE STRUCTURES SHALL BE EXCAVATION HAVE BEEN TOPBARS (AS REQ'D)
ADHERED TO, UNLESS OTHERWISE COMPLETED AND PRIOR TO 1. SEE TABLE OF LAP SPLICE AND ANCHORAGE db

SHOWN OR NOTED. CONCRETING TO CONFIRM THE LENGTHS SHOWN ON SHEET


5. MAINTAIN MINIMUM CONCRETE DESIGN SOIL BEARING CAPACITY. 2. LAP SPLICE SHALL BE LOCATED ONLY WITHIN THE
I.D = 4db
COVER FOR REINFORCING STEEL AS 4. BLOCK WALL REINFORCING BARS LAP SPLICE ZONE

EQUAL
FOLLOWS: SHALL BE LAPPED A MINIMUM OF 30 3. CLOSED HOOPS WITH A 135° BEND SHALL BE

SEE SCHEDULE
40MM CLEAR TO
Suspended Slabs 3/4 in. (19 mm) BAR DIAMETERS WHERE SPLICED, SPACED AT 100mm ON CENTER MAXIMUM AT A STIRRUPS TYPICAL
HORIZONTAL / VERTICAL DOWELS DISTANCE 3d FROM THE FACE OF THE SUPPORT,

D
Slab on Grade 1 1/2 in. (38 mm)
FROM FOOTINGS, COLUMNS / FIRST STIRRUP SHALL 5d FROM THE FACE OF THE

EQUAL
Beam Stirrups and Column Ties 1 1/2 in. (38 mm) WALLS OR SLABS SHALL EXTEND INTO SUPPORT
Where concrete is exposed to earth but 2 in. (50 mm) THE BLOCK WALL A MINIMUM IF 30 4. SPACING OF STIRRUPS ON LAP SPLICE SHALL BE BEAM STIRRUPS
poured against forms
BAR DIAMETERS OR A SPACED 100mm ON CENTER MAXIMUM ADDITIONAL ROW OF
Where concrete is deposited directly against 3 in. (75 mm)
earth REINFORCEMENT OF WALL. 5. AT INTERIOR SUPPORT (CONTINUOUS END) PROVIDE TOPBARS (AS REQ'D)

5. ALL CELLS CONTAINING LARGER SIZE AND NUMBER OF TOP AND BOTTOM BOTTOM BARS
6. SPLICES SHALL BE SECURELY WIRED REINFORCING BARS OR INSETS BARS FROM ADJACENT SPANS NOTE:
NOTE:
WEB BARS (TYPICAL)
TOGETHER AND SHALL LAP OR EXTEND SHALL BE SOLIDLY FILLED WITH 6. NO SPLICE SHALL BE ALLOWED 2d FROM THE FACE SLAB REINFORCEMENT
IN ACCORDANCE WITH TABLE 1 OF THE SUPPORT NOT SHOWN FOR CLARITY W
CONCRETE GROUT (REFER TO
SEE SCHEDULE
(TABLE OF LAP SPLICE AND SPECIFICATIONS).
PRC Reg. No.: PRC Reg. No.: PROJECT NAME and LOCATION: OWNER SHEET CONTENTS:

CONSTRUCTION NOTES
PTR. No.:

PLACE of ISSUE:
PTR. No.:

PLACE of ISSUE:
PROPOSED SIX-STOREY SCHOOL BUILDING
EINSTEIN ACADEMY MS. HONGLIFEI CHEN
STRUCTURAL NOTES
TYPICAL BEAM DETAILS
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE BY
ALPHA OMEGA DESIGN AND BUILD SERVICES CO.
ALL DISCREPANCIES ARE TO BE IMMEDIATELY REPORTED TO
ARCHITECTS AND PROJECT MANAGERS. CONTRACTORS ARE TO
S-14
PREPARE AND SUBMIT SHOP DRAWINGS TO ARCHITECTS PRIOR TO
ARCHITECT ENGINEER #9ARTY II TALIPAPA QUEZON CITY C OM M E N C E M E N T OF W OR K S . T H I S D R A W I N G A CT I N G A S