Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
85 views3 pages

Q Scope™250

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 3

Q-Scope
250
Designed for ease of use
for industry and academia
with non-destructive,
large sample scanning, the
Q-Scope 250 is a complete
turnkey Scanning Probe
Microscope (SPM). Its
standard, user-friendly
features provide the best
SPM value in the industry.
Utilizing a video micro-
scope with a 90¡ top down
view for easy laser align-
ment, it has the capability
to quickly find sample fea-
tures and align the probe
over them. A manual X-Y
translation stage can han-
dle up to 6" diameter sam-
ples. Add options such as
a sample heater stage,
scanning in liquids,
motorized X-Y translation
stage, Magnetic Force
Microscopy and extended
Z range of 20mm and the
Q-Scope 250 becomes cus-
tomized for you.

NanoScanning
Your World
Standard Features Technical data

¥ Scanning Modes: Contact AFM- Z Height and Component Feature


Lateral Force, Intermittent Contact AFM
(WaveModeª) and Phase Mode. AFM Scanning Head
Scanning Part Cantilever
¥ Isotopic Focal Systemª allowing systematic Scanning Element PZT Tube(s)
laser beam tracking of the cantilever/probe Scanning Range & See scanning head
during scanning. (Quesant Patent) Resolution specification

¥ Unique Broadband Feature, providing a broader Sample and Probe


frequency response and better image data by Viewing
combining Z height and PID loop error signals. Video Microscope 200X Magnification

¥ Computer-controlled Z-Axis approach - fully Power Requirements 100-115v/60Hz/5A


automated from any height. 220-240v/50Hz/3A

¥ QLithicª granite stage (65 lbs. of stability). Stage Type Granite

¥ Renowned ease-of-use (probe change/laser Maximum Sample


alignment, and PID loop gain optimization) Size 6" x 6"/150mm x 150mm
within industry.
Maximum Sample
Heights 2.5"/67mm
¥ A proven, simple and rugged, integrated
design ensuring: X-Y Translation Stage Manual
-Versatility for upgrades (common design)
X-Y Translation Stage
-Reliability (years of problem free history) Travel 0.5"/12.5mm

¥ Analog PID loop (AnaLoopª) with digital Z Translation Stage Motorized and automated
input allows faster, more accurate data gather-
Electronic Interface Unit
ing. (Quesant Patent)
PID Loop
¥ Windows-based ScanAtomicª control and (AnaLoopª) Analog
analysis software. Digital Interface 16 Bit A/D and D/A

¥ Complete turnkey system including state-of- PC Interface Digital Signal Processor


the-art PC computer.
Maximum Image
(Data) Resolution 1024 x 1024 pixels

Available Options Display Resolution 1024 x 768 pixels, 65,000


colors
Magnetic Force Microscopy
Electric Force Microscopy
LiquiScanª Head (Capable of Scanning in Liquids)
Sample Heater with controller.
Range: Ambient to 250°C
Hysitron Interfaceª for nanoindenting and
nanoscratching (property of Hysitron Inc.)
Acoustic/Vibration Isolation Chamber (AVIC)
Motorized X-Y Translation Stage
Research Customization Package
Q-Analysis-Enhanced Analysis and Reporting
Software.
Other Specifications

1 Motorized Translation Stage(2) 6 Number of Displayed


Simultaneous Images: 2
1.1 X-Y Movement Accuracy:
4 to 5mm
7 Network Capability: The comput-
1.2 Translation: 0.5" in X and Y er can be attached to a network
1.3 Working Area: 6" x 6" but ScanAtomic software is not
multi-user and can only be used
1.4 X-Y Movement Resolution:
to operate the Q-Scope on the
2mm
Quesant-supplied computer sys-
1.5 Repeatability: 95% tem. However, additional copies
of ScanAtomic can be installed on
2 Enhanced Motorized Translation off-line computers attached to the
Stage(2) network and used for post-pro-
cessing images.
2.1 X-Y Movement Accuracy:
500nm
8 Footprint: 14"D x 10" W x 16" H
2.2 Translation: 1.0" in X and Y (not including computer, monitor
2.3 Working Area: 6" x 3.5" and Electronic Interface Unit).
2.4 X-Y Movement
Resolution: 2mm 9 Footprint of Acoustic/Vibration
Isolation Chamber: 22"D x 22"W
2.5 Repeatability: 99% x 24" H.
2.6 Separate programmable
controller with manual 10 Weight: 65 lbs. (all weights are
front panel plus joystick approximate, and do not include
control computer, monitor and Electronic
Interface Unit).
3 Motorized Z
3.1 Z Movement Accuracy: 11 Power Requirements: Specify 110
10nm volts/50 or 60 cycles, or 220
volts/50 cycles. A line filter is
3.2 Z Movement Resolution: highly recommended.
29397 Agoura Road, Suite 104 20nm
12 Standard Warranty: 100% on
Agoura Hills, CA 91301 4 Maximum Sample Size (X x Y x Z): parts and labor on workmanship
4.1 Standard Translation for one year after installation.
Stage: 6" x 6" x 2"
Phone (818) 597-0311
4.2 Enhanced Translation 13 Yearly Service Contract: Based on
Stage: 6" x 4" x 2" 10% of the product price, this
Fax (818) 991-5490 service contract takes over after
the first-year warranty; 100% on
5 Maximum Number of Captured
E-mail qsales@quesant.com parts and labor on workmanship.
Simultaneous Images: 4

Web www.quesant.com

All trademarks are the property of Quesant


Instrument Corporation.