Alternators: LSA 42.2 - 2 Pole
Alternators: LSA 42.2 - 2 Pole
2007 / c
35
30
25
20
15
10
ALTERNATORS
LSA 42.2 - 2 Pole - Three phase
Electrical and mechanical data
ALTERNATORS
ELECTRICAL DATA
LSA 42.2 - 2P 50 Hz 3000 min-1
TYPICAL DATA
Insulation class H Excitation system Shunt
Winding pitch - Code 2/3 - (N° 6) A.V.R. model R 250
Leads 12 Voltage regulation (steady state) ± 0,5 %
Drip proof IP 23 Sustained short-circuit current -
Altitude ≤ 1000 m Total harmonic (*) TGH / THC <4%
Overspeed 4500 min -1 Wave form : NEMA = TIF - (*) < 50
Air flow 0,22 m3/s Wave form : I.E.C. = THF - (*) <2%
(*) Total harmonic content line to line, at no load or full rated linear and balanced load
42.2 M5 78,7 85 86,1 85,9 85,5 80,1 87,2 89,2 89,6 89,5 69,4 77,1 78,2 77,2 76,6 71 80,2 82,6 82,9 82,7
42.2 M6 81,1 85,8 86 85,1 84,5 82,7 88,4 89,5 89,4 89,2 72,2 77,9 77,7 75,7 74,8 74,2 81,7 82,9 82,4 82
42.2 L7 83,3 87,6 87,8 87 86,5 84,6 89,8 90,8 90,7 90,5 75,2 80,3 80 78,2 77,4 76,9 83,6 84,6 84 83,6
42.2 VL8 84,4 88,8 89,3 88,7 88,4 85,6 90,7 91,8 91,8 91,7 76,8 82 82 80,5 79,8 78,3 84,9 86 85,7 85,3
According to : I.E.C. 34.1/34.2 - U.T.E. : NF C 51.111 - V.D.E. 0530 - B.S. 4999 & 5000 - NEMA : MG 1.22 - ISO 8528 . 3 - CSA (upon request) ....
Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization.
Their description cannot, in any case, engage Leroy-Somer liability. The values indicated are typical values .
ALTERNATORS
TRANSIENT VOLTAGE
LSA 42.2 - 2P VARIATION
50 Hz - 400 V
TRANSIENT VOLTAGE VARIATION - 400V
M5 M5
Load application M6 Load rejection
30 45 M6
L7
40
25 L7
35
VL8
20 30
% Voltage rise
% Voltage dip
VL8
25
15
20
10 15
10
5
5
0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
kVA at 0,8 power factor kVA at 0,8 power factor
Motor starting
40 M5 M6 L7 VL8
30
% Voltage dip
20
10
0
0 20 40 60 80 100 120 140 160
Locked rotor - kVA at 0,6 power factor
1) For a starting P.F. differing from 0,6 the starting kVA have to be multiplied by (Sine Ø /0,8)
2) If voltage is not 400V(Y) , 230V(∆) at 50 Hz then kVA must be multiplied by (400/U)2 or (230/U)2.
Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization.
Their description cannot, in any case, engage Leroy-Somer liability. The values indicated are typical values .
ALTERNATORS
ELECTRICAL DATA
LSA 42.2 - 2P 60 Hz 3600 min-1
TYPICAL DATA
Insulation class H Excitation system Shunt
Winding pitch - Code 2/3 - (N° 6) A.V.R. model R 250
Leads 12 Voltage regulation (steady state) ± 0,5 %
Drip proof IP 23 Sustained short-circuit current -
Altitude ≤ 1000 m Total harmonic (*) TGH / THC <4%
Overspeed 4500 min -1 Wave form : NEMA = TIF - (*) < 50
Air flow 0,26 m3/s Wave form : I.E.C. = THF - (*) <2%
(*) Total harmonic content line to line, at no load or full rated linear and balanced load
42.2 M5 75,8 83,7 85,6 85,9 85,8 76,9 85,5 88,2 89,1 89,2 65,7 75,1 77,2 76,9 76,5 66,9 77,6 80,8 81,6 81,5
42.2 M6 78,6 84,9 85,9 85,5 85,2 79,9 87 88,9 89,3 89,2 69,2 76,5 77,1 75,8 75,1 70,6 79,5 81,5 81,4 81,1
42.2 L7 81,4 86,8 87,7 87,2 86,9 82,5 88,7 90,3 90,5 90,4 71,6 78,6 79,2 78,1 77,4 72,9 81,3 83,1 83,1 82,8
42.2 VL8 82,4 88 89,1 89 88,8 83,3 89,6 91,3 91,7 91,7 74 80,7 81,4 80,4 79,8 75,2 83,1 84,9 84,9 84,7
According to : I.E.C. 34.1/34.2 - U.T.E. : NF C 51.111 - V.D.E. 0530 - B.S. 4999 & 5000 - NEMA : MG 1.22 - ISO 8528 . 3 - CSA (upon request) ....
Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization.
Their description cannot, in any case, engage Leroy-Somer liability. The values indicated are typical values .
ALTERNATORS
TRANSIENT VOLTAGE
LSA 42.2 - 2P VARIATION
60 Hz - 480 V
TRANSIENT VOLTAGE VARIATION - 480V
M5
Load rejection M5
Load application M6
M6
30 45
L7
40
25 L7
35
VL8
20 30
% Voltage rise
% Voltage dip
VL8
25
15
20
10 15
10
5
5
0 0
0 20 40 60 80 100 0 20 40 60 80 100
kVA at 0,8 power factor kVA at 0,8 power factor
Motor starting
40 M5 M6 L7 VL8
30
% Voltage dip
20
10
0
0 20 40 60 80 100 120 140 160 180 200
Locked rotor - kVA at 0,6 power factor
1) For a starting P.F. differing from 0,6 the starting kVA have to be multiplied by (Sine Ø /0,8)
If voltage is not 480V(Y), 277V(∆), 240V(YY ) at 60 Hz then kVA must be multiplied by (480/U)2 or (277/U)2 or (240/U)2.
Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization.
Their description cannot, in any case, engage Leroy-Somer liability. The values indicated are typical values .
ALTERNATORS
SINGLE BEARING
LSA 42.2 - 2P DIMENSIONS
DIMENSIONS
Cable output
BH
fl N - 0,127
- 0,050
fl BX - 0,100
445
§
0
G
fl 53
fl P
fl 315
+1
180 -3
holes on AJ P.C.D.
6
Y DIA, X Eq. Sp. holes
on P P.C.D.
AIR OUTLET 279
3 85 110 AIR INLET
14
340
W 260 18 BL
Xr
Ø 58,5
Ø 25
Ø 53
Ø 18
Ø 60
Ø 55
Ø 63
Lr
CENTRE OF GRAVITY : Xr (mm) - ROTOR LENGTH : Lr (mm) - MASS : M (kg) - MOMENT OF INERTIA : J (kgm2) : (4J = MD2)
Flex pl. S.A.E. 6 1/2 Flex pl. S.A.E. 7 1/2 Flex pl. S.A.E. 8 Flex pl. S.A.E. 10 Flex pl. S.A.E. 11 1/2
TYPE Xr Lr M J Xr Lr M J Xr Lr M J Xr Lr M J Xr Lr M J
LSA 42.2 M5 256 472 34,8 0,089 256 472 34,9 0,091 284 472 35,2 0,094 273 472 35,7 0,104 256 472 36,2 0,112
LSA 42.2 M6 256 472 34,8 0,089 256 472 34,9 0,091 284 472 35,2 0,094 273 472 35,7 0,104 256 472 36,2 0,112
LSA 42.2 L7 278 517 41,9 0,107 277 517 42 0,109 306 517 42,3 0,113 295 517 42,8 0,121 278 517 43,3 0,13
LSA 42.2 VL8 308 577 48,3 0,133 307 577 48,4 0,135 336 577 48,7 0,139 325 577 49,2 0,148 308 577 49,7 0,157
Les produits et matériels présentés dans ce document sont à tout moment susceptibles d'évolution ou de modifications tant aux plans technique et d'aspect que d'utilisation.
Leur description ne peut en aucun cas revêtir un aspect contractuel.Les valeurs indiquées sont des valeurs typiques
ALTERNATORS
TWO BEARINGS
LSA 42.2 - 2P DIMENSIONS
DIMENSIONS
L Access to terminals
LB 358
82 Xg 266 11 Access to
Cable output regulator
M 16 x 36 109
22¡30’
fl 315
fl 266,7 - 0,127
445
+ 0,025
fl 42 + 0,009
0
G
fl 358
fl 310
195
12
+1
180 -3
45
6
AIR OUTLET AIR INLET 279
55 85 9
14
18 340
5 278 18 M10 DIA, 8 Eq. Sp. holes on 285,75 DIA (SAE 6)
TYPE L maxi LB Xg M
Xr
Ø 58,5
Ø 45
Ø 42
Ø 25
Ø 53
Ø 60
Ø 55
Ø 63
Lr
CENTRE OF GRAVITY : Xr (mm) - ROTOR LENGTH : Lr (mm) - MASS : M (kg) - MOMENT OF INERTIA : J (kgm2) : (4J = MD2)
TYPE Xr Lr M J
Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization.
Their description cannot, in any case, engage Leroy-Somer liability. The values indicated are typical values .