TP 02i User's Manual
TP 02i User's Manual
TP 02i User's Manual
1 General Description....................................................................................... 1
1.1 Functions and Characteristics ....................................................... 1
1.2 Front Panel......................................................................................... 2
1.3 Technical Specifications................................................................... 3
1.3.1 Common................................................................................ .3
1.3.2 Analog.....................................................................................4
1.3.3 Digital...................................................................................... 4
2 Installation and Wiring................................................................................... 5
2.1 Connection of Power Supply........................................................... 5
2.2 Connection of Load Cell................................................................... 5
2.2.1 6-wired Connection.............................................................. 6
2.3 I/O terminals....................................................................................... 7
2.4 Optional Expansion Board Output.................................................. 8
2.4.1 Analog Output (Optional) ................................................. 8
2.4.2 Serial Interface RS485 Output..........................................11
2.4.3 Serial Interface RS232 Output......................................... 12
3 Calibration..................................................................................................... 13
3.1 Instruction......................................................................................... 13
3.2 Flow Chart of Calibration............................................................... 14
3.3 Millivolt Value Display..................................................................... 20
3.4 Calibration with Weights.................................................................20
3.5 Millivolt Calibration.......................................................................... 20
3.6 Calibration Switch for Communication Interface........................ 22
3.7 Explanation for Calibration Parameters.......................................23
4 Working Parameters Setting...................................................................... 25
4.1 Flow Chart of Working Parameters Setting.................................25
4.2 Parameter Setting Method.............................................................27
4.3 Descriptions of Operation Parameters........................................ 28
4.4 Set point parameters...................................................................... 31
5 I/O Definition................................................................................................. 33
5.1 I/O Definition.................................................................................... 33
5.2 I/O testing......................................................................................... 35
6 Serial Communication................................................................................. 36
6.1 r-Cont................................................................................................ 37
6.2 r-SP1................................................................................................. 37
6.2.1 Parameters Code Chart.................................................... 37
6.2.2 Error Code Explanation..................................................... 40
6.2.3 Command............................................................................ 40
6.3 tt TOLEDO....................................................................................... .48
6.4 Cb920................................................................................................49
6.5 rECont............................................................................................... 50
6.6 rEREAD............................................................................................ 51
6.7 Modbus............................................................................................. 52
6.7.1 Modbus Communication Address.................................... 53
7 Password Input and Setting, Reset.......................................................... 59
7.1 Password Input................................................................................ 59
7.2 Password Setting............................................................................ 59
7.3 Factory Reset.................................................................................. 61
8 Display Testing............................................................................................. 63
9 Errors and Alarm Messages.......................................................................64
10 Dimension of Indicator.............................................................................. 65
1 General Description
M02 weighing indicator is specially designed for weight transmitting in industrial
fields.
This indicator has the features of small volume, plenty communicating commands,
stable performance, easy operation and practicability. It can be widely applied to
concrete and bitumen mixing equipment, metallurgy furnace and converter, chemical
industry and feed, etc. .
1.1 Functions and Characteristics
Small volume, unique design, easy operation
Applicable to all kinds of resistance strain gauge bridge load cell
Front panel numerical calibration
Multilevel of digital filter
Automatic zero -tracking
Automatically zero when powered on
4 set points
1 input and 2 outputs
Serial communication interface:RS232 or RS485
Calibration via serial interface
Optional interfaces: Analog output, serial interface
1
1.2 Front Panel
2
: Zero/Esc, Used to exit from current operation or go previous.
: Function Selecting Key, To make flashing position move to the right digit
when data inputting.
1.3.1 Common:
Power supply: DC24V±5%
Working temperature: -10 40
Max humidity: 90%R.H without dew
Power consumption: About 10W
Dimension: 110×89×60 mm
3
1.3.2 Analog:
Load cell power: DC5V 200mA MAX
Input impedance: 10M
Zero steady range: 0.00 12mV(Load cell 3mV/V)
Input sensitivity: 0.1uV/d
Input range: 0.00 15mV(Load cell 3mV/V)
Transfer mode: Sigma - Delta
A/D conversion speed: 15, 30, 60, 120, 480, 960 times/sec
Non-linearity: 0.01% F.S
Gain drift: 10PPM/
Display Precision: 1/100,000
1.3.3 Digital:
Weight display: 6 digits red high-brightness LED
Minus display: -
Overload display: OFL
Decimal point: 5 kinds (optional)
Function keys: 4 keys soniferous keypad
4
2 Installation and Wiring
2.1 Connection of Power Supply
M02 weighing indicator connects DC24V power supply as follows:
5
6 wires EX+ SN+ EX- SN- SIG+ SIG- Shield
Note:
1. As load cell output sensitive analog signal, please use shield cable to separate
with other cables, especially AC power.
2. 4 wires connection is suitable for short distance and stable temperature or low
precision field, otherwise use 6 wires connection.
3. For more load cells parallel connection, their sensitivity (mV/V) should be same.
6
2.3 I/O terminals
7
2.4 Optional Expansion Board Output
M02 weighing indicator supports analog output, RS232 or RS485 as optional
8
The definition of analog output:
V+: voltage-output+, V-: voltage-output-
I+: current-output +, I-: current-output -
The analog output has been calibrated before the delivery of the indicators, so
users do not need to make calibration. If analog output is abnormal, users can
calibrate by themselves as follows: Suggestion: please calibrate under the
instruction of professionals)
SET UP calibration.
9
and
In this interface the
Current calibration interface multimeter measured
should be 4.000mA.
If not,press
Measured 4.000mA
press to save and exit. Finish the calibration referring to the process of
4.000mA calibration, and the same for the
Then press to calibrate calibration of 20mA.
12.000mA.
10
This interface is the highest
point calibration of analog
output.
11
3 Calibration
3.1 Instruction
1 Calibration procedure must be executed when a M02 indicator is put in use at the
first time, the preset parameters may no longer meet the user s needs, and any part of
the weighing system was changed. Position of decimal point, minimum division,
maximum capacity, zero, and gain can be set and confirmed through calibration.
2 If you want to set only one parameter, please press to save parameter s
13
3.2 Flow Chart of Calibration
1. Under this status, press (twice),
indicator will display CAL, then
next step.
Decimal point
press directly to enter next step.
14
4. Press to select a desired value for min.
division among 1,2,
5,10,20 and 50, and then to save it and enter next
step.
Min. divistion If there no need to change the value, then
15
7.Unloaded scale first, when STAB lamp is on,
16
8. The process of gain calibration is as follows. If there s no need to do gain calibration, press
17
9. Press to enter setting interface,
18
3.3 Millivolt Value Display
This function is mainly used for system test, position-error test for weighing
mechanism and linearity test for load cell.
1. System Test
(1) If display data changes with loaded weight changes, it shows that connection
of load cell is correct and weighing mechanism works well.
(2)If display value is OFL (or OFL), it means that loaded weight on load cells is
too large (or too small). Please unload the weight (or load more), if display value is still
OFL (or OFL), the possible reasons are as follows:
a. There is something wrong with weighing mechanism, please check and clear.
b. The connection of load cell is incorrect, please check and clear.
c. Load cells may be damaged, please replace.
2. Position-error Test for Weighing Mechanism
Load a same weight on each corner of weighing mechanism and record
displayed millivolt value respectively. If differences among these values are obvious,
please adjust weighing mechanism.
3. Linearity Test for Load Cell
Load same weight for several times, and record displayed value every time. If
one or two values are obviously much larger or smaller than any others, it means that
the linearity of load cell is bad.
*NOTE: You must use to zero display data before weight is
loaded for each time.
19
3.4 Calibration with Weights
During calibration with weight please record the zero millivolt value, gain millivolt
value and the loaded weight value in the blank table below. If it is not convenient to load
a weight to calibrate, these values can be used for calibration without weights.
Zero millivolt Gain millivolt Loaded Date Remarks
value(mV) value(mV) Weight
1
2
3
4
5
3.5 Millivolt Calibration
When it is not convenient to load a weight to calibrate alibration can be done without
weights using recorded data in the table in section 3.4.
However, this method is just used for some emergencies, it will make calibration
result incorrect if load cells, or indicator has been replaced.
20
21
22
3.6 Calibration Switch for Communication Interface
When calibrate the transmitter through serial port( Rs SP1 or Modbus), must set to
ON status for the calibration switch for communication interface.
3.7 Explanation for Calibration Parameters
Symbol Parameter Types Value of parameter Default
Pt Decimal Point 5 0 0.0 0.00 0.000 0.0000 0
1d Min. Division 6 1 2 5 10 20 50 1
CP Max. Capacity Min. Division×100000 10000
t Millivolt Value
o Zero
C Gain
Switch for
Calibration
SIOCAL via serial OFF
interface
23
Log Table for Calibration Parameters
Parameter Calibrated Value Date Remarks
Decimal Point
Min. Division
Max. Capacity
Load cell sensitivity
Password
24
4 Working Parameters Setting
Normal Status
F1 F1.1 F1.7
25
F2 F2.1 F2.7
F3 F3.1 F3.2
F4 F4.1
26
4.2 Parameter Setting Method
M02 has 2 kinds of working parameters: Selection type and data type. For
Selection:
Data:
F1.4 50 50 60
Confirm change
F1.4
27
4.3 Descriptions of Operation Parameters
Code Default Description
F1 Null The first major term of working parameter.
F1.1 OFF Switch for Auto-Zeroing when power-on,
OFF: disabled ON: enabled
F1.2 0 Zero-tracking Range 0 9d optional .
This parameter is for automatic calibration, disabled
when is set .
F1.3 1 Motion Detecting Range 1 9d optional)
28
F2 Null The second major term of working parameter.
F2.1 01 Scale no., indicator no.
F2.2 9600 Baud rate of serial port
29
HiLo MODBUS dual-byte register storage turn Hi Lo
F2.5 High byte in the front, low byte at the back Lo Hi Low
byte in the front, high byte at the back
F2.6 nonE Cont mode automatic sending time interval
tt(TOLEDOcontinuous mode)If send the checksum
F2.7 0
0 not send, 1 send.
The third major term of working parameter.
F3 Null
(For analog output only)
Analog output:
4-20 4-20mA
0-20 0-20mA
0-24 0-24mA
F3.1 0-5 0-5: 0-5V
0-10: 0-10V
I_out Current customized
V_out Voltage customized
In customized mode,F3.2-F3.5 parameters available
F3.2 3920 Minimum output
F3.3 4000 Zero point output
30
F3.4 20000 Maximum capacity output
F3.5 20020 Maximum output
F4 Null The fourth major term of working parameter.
F4.1 OFF Parameters password setting switch.
F4.2 000000 Parameters password setting:Valid when F4.1 is ON
4.4 Set point parameters
Code Default Description
P1-P4 Null The first term of working parameters
PX.1 OFF Change of state if need stable
31
6 != compare to minimum value
7 _<>_outside the range, need to set 2 edge value
8 =< >=inside the range, need to set 2 edge value
9 external trigger. If it s IO do 1 state change for 1
trigger, if it s command, then decide according to
valid or invalid command.
PX.4 0 Set value 1 Set value 1 and set value 2, choose the
minimum to compare
PX.5 0 Set value 2
32
5 I/O Definition
5.1 I/O Definition
Output/Input code table:
Output
O0 None No definition
33
Input
I0 None No definition
34
I6 Reset all Reset all paramater value when this signal is valid.
status flash.
35
6 Serial Communication
M02 has RS232 or RS485 as optional to realize communication with upper
computer Support r-Cont r-SP1 Modbus(bus) tt TOLEDO Cb920 rECont
protocols and rErEAD protocol.
Serial communication terminal please refer to chapter 2.4.2 2.4.3. Baud rate and
communication format setting please refer to F2.2 F2.3 and F2.4.
Under main display display weight value), long press to enter into serial
communication checking interface, it will display ------ if no communication, and ------
will flash if there s communication.
6.1 r-Cont
Indicator will send weighing data to host computer without command.
Data Format:
STX Scale Channel Status Value CRC CR LF
no. no.
Here:
STX 1bit start character 02H
Scale no. 2bits 00~99
Status 2bits high byte:40H low byte definition as follows:
36
D6 D5 D4 D3 D2 D1 D0
G./N. Zero
Null Null +/- OFL Stable
weight point
0 + 0 0 0 not
1 0 0 1 - non/zero normal stable
1 zero 1 OFL 1 stable
Weight Value 6 bits when weight is+ - overflow,return to space space OFL
space
CRC 2 bits,check sum
CR 1 bit 0DH
LF 1 bit 0AH
For example:
02 30 31 31 4041202020373030 32 34 0D 0A
Means: stable,positive data,present weight 700
6.2 r-SP1
Code : ASCII
Operation code supported: W write R, read C calibrate O, zero
6.2.1 Parameters Code Chart
37
Operation Para. code Para. Name number of character
code
R WT Read current status 8
and weight
R SP Read set point status 4
W DC Write mini. Divistion and 8
max. capacity
R/W PT Decimal point digit 1
R DD Minimum division 2
R CP Maximum capacity 6
R/W AC Auto. Zeroing switch 1
R/W TR Zero tracking range 1
R/W MR Stable range 1
R/W ZR Zeroing range 2
R/W FL digital filtering para. 1
R/W VC steady filtering 1
R/W AD AD sample rate 1
R PO Set point output status 4
R/W P1M~P4M Set point to judge if 1
need stability
R/W P1T~P4T Set point minimum 3
duration time
R/W P1F~P4F Set point comparison 1
condition to judge
R/W P1L~P4L Set point lower edge 6
38
value to judge
R/W P1H~P4H Set point upper edge 6
value to judge
7: D6D5D4D3D2D1D0;
R AM Absolute millivolt D6:+;D5-D0: corresponding ASCII for 6 digits
millivolt,Decimal point is fixed to 3 digits
7 D6D5D4D3D2D1D0
R RM Relative zero point on D6 +/-;D5-D0:corresponding ASCII for 6
millivolt digits Decimal point is fixed to 3 digits
C ZY Zero calibration with
weight
C ZN Zero calibration 6
without weight
C GY Gain calibration with 6
weight
C GN Gain calibration 12
without weight
O CZ Zero clearing
command
O P1S~ Setting the Valid when 9,command valid when external
P4S corresponding set trigger and 1 status change for 1 external
point Trigger
O P1C~P4 Clear the
C corresponding set
point
39
6.2.2 Error Code Explanation
1 CRC check error
2 Operation code error
3 Parameters code error
4 Write data error
5 Operation invalid
6 Channel no. error
Note Default channel no. of this indicator : 1 31H
6.2.3 Command
Indicator will send weighing data to host computer after received command.
6.2.3.1 Host computer read present status
Send command:
STX Scale no. Channel No. R WT CRC CR LF
Correct response:
STX Scale Channel R WT Status Value CRC CR LF
no. No.
Wrong response:
STX Scale Channel R WT E Error code CRC CR LF
no. No.
Here
40
STX 1bit start character 02H
R 1 bit 52H
WT 2 bit 57H 54H
E 1 bit 45H
Status 2bits high byte: 40H low byte definition as follows:
D6 D5 D4 D3 D2 D1 D0
G./N.
Null Null +/- Zero point OFL Stable
weight
0 + 0 non/zero 0 normal 0 not stable
1 0 0
1 - 1 zero 1 OFL 1 stable
Weight Value 6 bits when weight is+ - overflow,return to space space OFL
space
For example:
02 30 31 31 525754 30 31 0D 0A
Correct response 02 30 31 31 52 57 54 4041303033373533 33 36 0D 0A
stablepresent value 3753
Wrong response: 02 30 31 31 52 57 54 4531 31 39 0D 0A CRC check error
6.2.3.2 Read other parameters
Send command:
STX Scale no. Channel No. R Para. code CRC CR LF
41
Correct response:
STX Scale no. Channel No. R Para. code Value CRC CR LF
Wrong response:
STX Scale Channel R Para. E Error code CRC CR LF
no. No. code
Here:
Para. Value 1bit
Para. code 2 bits
For example:
02 30 31 31 524D52 3839 0D 0A
Correct response 02 30 31 31 52 4D 52 36 34 33 0D 0A stable range 6
Wrong response:02 30 31 31 53 4D 52 4532 30 39 0D 0A Operation code error
6.2.3.3 Write max. Capacity and min. Division
Send command:
STX Scale Channel W DC Division Max. CRC CR LF
no. No. value capacity
Correct response:
STX Scale no. Channel No. W DC O K CRC CR LF
Wrong response:
STX Scale Channel W DC E Error code CRC CR LF
42
no. No.
Here:
DC 2 bits 44H 43H
O 1 bit 4FH
K 1 bit 4BH
Division value 2 bits 1/2/5/10/20/50
Max. capacity 6 bits
For example:
02 30 31 315744433035303130303030 36 30 0D 0A(division value 5, Max capacity
10000)
Correct response: 02 30 31 31 57 44 43 4F 4B 32 34 0D 0A
Wrong response: 02 30 31 31 57 44 43 4535 39 32 0D 0A Operation ca t execute
6.2.3.4 Write other parameters
Send command:
STX Scale Channel W Para. Para. CRC CR LF
no. No. code value
Correct response:
STX Scale Channel W Para. O K CRC CR LF
no. No. code
Wrong response:
STX Scale Channel W Para. E Error CRC CR LF
43
no. No. code code
For example:
02 30 31 31575A523530 30 38 0D 0A Write zeroing range to 50
Correct response: 02 30 31 31 57 5A 52 4F 4B 36 31 0D 0A
Wrong response: 02 30 31 31 57 5A 53 4533 32 38 0D 0A Para. Code error
6.2.3.5 Calibration Zero
1 Calibrate zero as per current weight with weight
Send command:
STX Scale no. Channel No. C ZY CRC CR LF
Correct response:
STX Scale no. Channel No. C ZY O K CRC CR LF
Wrong response:
STX Scale no. Channel No. C ZY E Error code CRC CR LF
Here:
Z 1 bit 5AH
Y 1 bit 59H
For example:
02 30 31 31 435A59 39 34 0D 0A
Correct response:02 30 31 31 43 5A 59 4F 4B 34 38 0D 0A
Wrong response:02 30 31 34 43 5A 59 4536 32 30 0D 0A channel no. error
2 Input millivolt calibration zero in the chart without weight
44
Send command:
STX Scale no. Channel No. C ZN Zero millivolt value CRC CR LF
Correct response:
STX Scale no. Channel No. C ZN O K CRC CR LF
Wrong response:
STX Scale no. Channel No. C ZN E Error code CRC CR LF
Here:
ZN 2 bits 5AH4EH
Zero millivolt value 6 bits
For example:
02 30 31 31 435A4E303132363130 38 31 0D 0A
Correct response:02 30 31 31 43 5A 4E 4F 4B 33 37 0D 0A
Wrong response:02 30 31 31 43 5A 4E 4534 30 34 0D 0A Write data error
6.2.3.6 Gain calibration
1 With weights
Send command:
STX Scale no. Channel No. C GY Weight value CRC CR LF
Correct response
STX Scale no. Channel No. C GY O K CRC CR LF
Wrong response:
STX Scale no. Channel No. C GY E Error code CRC CR LF
45
Here:
GY 2 bits 47H 59H
Weight value 6 bits: Write in weight value
For example:
02 30 31 31434759303030323030 36 35 0D 0A Write in: weight value 200
Correct response: 02 30 31 31 43 47 59 4F 4B 32 39 0D 0A
Wrong response: 02 30 31 35 43 47 59 4536 30 32 0D 0A Channel no. error
2 Without weights
Send command:
STX Scale no. Channel No. C GN Gain millivolt Weight value CRC CR
Correct response:
STX Scale no. Channel No. C GN O K CRC CR LF
Wrong response:
STX Scale no. Channel No. C GN E Error code CRC CR LF
Here:
Gain millivolt 6 bits
Weight value 6bits
For example:
02 30 31 3143474E303031393430303030323030 35 36 0D 0A (Write in:
weight value 200 corresponding gain millivolt 0.194
Correct response: 02 30 31 31 43 47 4E 4F 4B 31 38 0D 0A
Wrong response: 02 30 31 31 43 48 4E 4533 38 35 0D 0A Para. Code error
46
6.2.3.7 Zeroing
Send command:
STX Scale no. Channel No. O CZ CRC CR LF
Correct response:
STX Scale no. Channel No. O CZ O K CRC CR LF
Wrong response:
STX Scale no. Channel No. O CZ E Error code CRC CR LF
For example:
02 30 31 31 4F 43 5A 38 34 0D 0A
Correct response: 02 30 31 31 4F 43 5A 4F 4B 33 38 0D 0A
Wrong response: 02 30 31 31 4F 43 5A 4535 30 36 0D 0A Operation ca t execuate
6.2.3.8 CRC computation
All the values in front of the parity bit add together and convert to decimal data,
then convert the last 2 bits to ASCII code (decade in front and the unit at the back).
For example
Add 02~5A: 180(Hex),convert to decimal data: 384. We can calculate from this
47
that the check code is 38,34 for the data frame.
6.3 tt TOLEDO Protocol
When choose tt protocol in working parameter F2.3, indicator will send datas in
continuous mode with TOLEDO protocol.
Continuous sending mode format as below:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
STX 0D
A B C display weight(6 bits) 6 30H Checksum
48
status byte B definition as below:
D6 D5 D4 D3 D2 D1 D0
6.4 Cb920
When F2.3=Cb920 in working parameter, indicator will send weighing data
continuously without command under Cb920 protocol.
Data format
Here
Status 2 bits OL ( 4FH 4CH ) OFL ST ( 53H 54H )Stable US ( 55H
53H )unstable
49
1 bit separator 2CH
G.W. 2 bits GS: gross weight 47H 53H
0/1 1 bit (30H/31H) interleaved transmission
Symbol 1 bit, 2BH + , 2DH -
Display 7 bits including decimal point
Unit 2 bits blank space 20H 20H
CR 1 bit 0DH
LF 1 bit 0AH
For example: When indicator send the following automatically:
53 54 2C 47 53 31 2B 20 20 31 39 30 2E 31 20 20 0D 0A
Means: Stable G.W. Data value is positive current weight is 190.1
6.5 rECont
Indicator will send weighing data to the upper computer continuously without any
command.
Return data frame format specification
Status GS +/- Display Unit CR LF
50
2bits 2C 47 53 2C 2B/2D 7bits 6B 67 0D 0A
Here:
Status 2 bits OL(OFL):4FH 4CH; ST(stable):53H 54H; US(unstable):55H 53H
Display value 7bits, including decimal point, high bit is blank if no decimal point.
For example: When indicator send the following automatically:
5354 2C 47 53 2C 2B3031312E313230 6B 67 0D 0A
Means Stable Data value is positive display value is 11.120kg
6.6 rEREAD
Indicator will send weighing data to the upper computer under command.
Data format
Data R E A D CR LF
explain 52H 45H 41H 44H 0DH 0AH
The return data frame is the same with that of rECont protocol, please refer to rECont.
51
6.7 Modbus
Indicator uses RTU mode to communicate, every 8-bit byte of the message are
divided into 2pcs of 4-bit hexadecimal characters to transmit at binary code.
Code: Binary
Function code:
52
programming condition.
request
6.7.1 Modbus communication address
PLC addr. Display Description
addr.
The following items are only-read register(code 0x03)
40001 0000 Present weight value(4bits including sign characters, the
40002 0001 high bit is in the front)
40003 0002 D15 D14..D5 D4 D3 D2 D1 D0
53
40010 0009 Stable range 1-9d
40011 0010 Zeroing range 0%-99%
40012 0011 Digit filter parameters(0-9)
40013 0012 Stability filter series(0-9)
40014 0013 AD sample rate 0:15/s 1:30/s 2:60/s 3 120 /s
4:480/s 5:960/s
40015~ 0014~
Reserved
40018 0017
40019 0018 Decimal point place 0:0bit,1:1bit,2:2bits,3:3bits,4:4bits
40020 0019 Minimum division 1/ 2/ 5/ 10/ 20/ 50
The following items are available to read and write
(writing code 0x10 read code 0x03
40021 0020
Maximum capacity max.capacity mini.division×100000
40022 0021
40023 0022 Zero calibration with weights: write in 1 and calibrate zero
40024 0023 with the current weight.
Read: Absolute millivolt of current load cell
40025 0024 Zero calibration without weights: Write millivolt value at
zero Write in range load cell 3mV/V:millivolt value range
40026 0025 within 0.02-12.000mV) millivolt value at zero when read.
54
40027 0026 Gain calibration with weights. Write weight value( max.
capacity). Return millvolt at present weight value when
40028 0027 read
40029 0028 Gain calibration without weights input gain millivolt(load
cell 3mV/V:0.000 millivolt<15.000mV zero
40030 0029
millivolt).Read: millivolt value for gain calibration.
40031 0030 Gain calibration weight without weights. input gain
millivolt( max. capacity) Read: weight value for gain
40032 0031 calibration.
40033~40040 0032~0039 reserved
40041 0040 Set point 1 stable or not 0 no 1 yes
40042 0041 Set point 1 min. duration time 0-999 : 0-99.9sec.
40043 0042 Set point 1 valid condition
40044~40045 0043~0044 Set point 1 set value 1
40046~40047 0045~0046 Set point 1 set value2
40048 0047 Set point 2 stable or not 0 no 1 yes
40049 0048 Set point 2 min. duration time 0-999 : 0-99.9sec.
40050 0049 Set point 2 valid condition
40051~40052 0050~0051 Set point 2 set value1
40053~40054 0052~0053 Set point 2 set value2
55
40055 0054 Set point 3 stable or not 0 no 1 yes
40056 0055 Set point 3 min. duration time 0-999 : 0-99.9sec.
40057 0056 Set point 3 valid condition
40058~40059 0057~0058 Set point 3 set value 1
40060~40061 0059~0060 Set point 3 set value 2
40062 0061 Set point 4 stable or not 0 no 1 yes
40063 0062 Set point 4 min. duration time 0-999 : 0-99.9sec.
40064 0063 Set point 4 valid condition
40065~40066 0064~0065 Set point 4 set value 1
40067~40068 0066~0067 Set point 4 set value 2
40069 0068 Output 1 user-defined
40070 0069 Output 2 user-defined
40071 0070 Input 1 user-defined
40072 0071 I/O output value Note: available only when coil address
I/O input value 00016 is valid.
40073 0072 Input write 1 valid 0 invalid.
Read 1 valid 0 invalid
The following items are bit read only. read code: 0x03
49001 9000 Version no. If display10024 formatXX XXXX,main
56
version no., hardware no., software
49002 9001 no..So main version no.01 hardware
no. 00 software no. 24
49003 9002 If display 141024, means 24th Oct.,
Develop time
49004 9003 2014
The following items are bit read only. read code 0 x 0 1
00001 0000 0 unstable 1 stable
00002 0001 0 normal 1 OFL
00003 0002 0 non-zero 1 zero
00004 0003 0 + 1 -
00005 0004 Reserved
00006 0005 Reserved
The following item are available to read and write
read code 0x01 writing code 0x05
00007 0006 Automatically zeroing when power on 0 OFF 1 ON
00008 0007 Reserved
00009 0008 Reserved
00010 0009 Reset all
57
00011 0010 Reset calibration
00012 0011 Reset paramaters
00013 0012 Reset I/O
00014 0013 Reserved
00015 0014 Reserved
00016 0015 I/O testing switch
00017 0016 Set point 1 status
00018 0017 Set point 2 status Only read
00019 0018 Set point 3 status 0:invalid 1:valid
00020 0019 Set point 4 status
00021~ 0020~
Reserved
00032 0031
58
7 Password Input and Setting, Reset
59
2 User must input same new password twice in setting password,If not same, main
60
7.3 Factory Reset
Note: Factory reset is only for special technicists, which will reset all of
parameters and will maybe cause not working.
61
1 In F SEt interface, press to reset working
parameters, enter into reset calibration paramters
F SEt interface.
2 In F SEt interface, press not to make working
parameter reset, enter into calibration para. Reset
interface.
F 1 In F CAL interface, press to reset calibration
para., enter into reset all interface.
62
8 Display Testing
The following flow chart is to test lights on main-display and status lights.
Normal weighing status
Under parameter interface,
Press 5 times
press to switch
SEt UP t ESt t tESt interface.
Under tESt nterface,press
press , display
will sparkle.
After testing is finished,
t ESt
press to return
t tESt nterface.
63
9 Errors and Alarm Messages
Error Input error.
wrong data beyond parameter range.
64
10 Dimension of Indicator