Line Data: Piping Isometric Drawings
Line Data: Piping Isometric Drawings
Line Data: Piping Isometric Drawings
IDENTIFICATION CODE
AREA NO. SHEET ISSUE
FLUID CODE P FLUID P, GENERAL PROCESS 4240 XHDL 4802A P0483247 4 A
ISOMETRIC LIST
REFERENCES
P0483247 B2A2 IH 95 4240-XZ-DM- 10 T CS4 4240-XH-LD-04802011001
PIPE SUPPORT SUMARY 4240-XH-LP-04802011001
A 30.09.2022 ISSUED FOR INTERNAL REVIEW R. Sawant S. Singh M. Pai
LINE ID PIPING CLASS THK.MM P&ID WELDING HEAT PAINTING
REV DATE REVISION DESCRIPTION DRAWN CHECKED APPROVED MATERIAL CLASS INSULATION CLASS TREAT. SYSTEM SPECIAL SUPPORT SUMMARY 4240-XH-LP-04802012001
N
ALL DIMENSION AND PROPER CONFIGURATION FOR LINES NPS 1.1/2" AND SMALLER SHALL BE CHECKED IN FIELD BEFORE CONSTRUCTION.
WITH THE AIM TO OPTIMIZE NUMBER OF SHOP WELDS THE SPOOLING ACTIVITY SHALL BE PREFERABLY AS COMPLETE LINES WITHIN A DEFINED CONSTRUCTION AREA.
PT N.S. HOLD
NO COMPONENT DESCRIPTION (INCH) ITEM CODE QTY STATUS
PIPE
N - CONVENTIONAL NORTH 1 PIPE - A106-B BE SMLS T01AC03V02 S-STD. 8 I117995 0.8 M
VALVE HANDWHEELS OR LEVERS ORIENATIONS MUST BE VERIFIED WITH 3D MODEL BEFORE INSTALLATION BY ERECTION CONTRACTOR.
FITTINGS
2 STRAIGHT TEE ASME B16.9 A234-WPB BE SMLS C31DC04V01 S-STD. 8X8 I129231 1
ACTUAL CUT LENGTH OF PIPE AND FIELD WELDS SHALL BE DEFINED BY ERECTION CONTRACTOR. GUSSETING TO BE IMPLEMENTED BY MECHANICAL SUBCONTRACTOR AS PER 4240-XH-SG-00000000002.
FLANGES
4 WN FLANGE ASME B16.5 300# A105 RFFE BE 125 - 250 AARH 8 I118284 2
F01CFC01BV05 S-STD.
PIPE SUPPORTS
5 WELDED GUIDE-C1G1 H = 150 L = 300 8 5135 1
CONT. ON
LINE P0483217-4
SPEC B2A2
AREA 4802A CONT. ON
E- 394.379M LINE P0483247-3
N- 1791.209M SPEC B2A2
EL +101.025M AREA 4802A
F4 E- 394.379M
STEM UP N- 1791.498M
ORIENT HANDLE EAST EL +101.202M
8"NPD 289
2
Rev. Cause ID
670 8X8"NPD
N- 1791.498M
This document is Tecnimont's property, and cannot be used by others for any purpose, without prior written consent.
S5
5135
G
POS: 1
STREAM VER NO.- 6
127
156 5
4
S6 STEM SOUTH
PIPE SUPPORT SHALL BE WELDED BEFORE THERMAL TREATMENT, WHERE APPLICABLE.
POS: 2
416
F4
CONT. ON
8"NPD LINE P0483217-3
STREAM NO.- 667
SPEC B2A2
AREA 4802A
E- 394.379M
CROSSING BETWEEN WELDS ON PIPELINE SHALL NOT BE ADMITTED. .
3 N- 1792.773M
EL +101.441M
REFER LATEST LINE LIST FOR PROCESS PARAMETERS .
Extr. Date 12-01-2023 12:30:42
PROJECT
1 DENOTES PARTS PIPE A = RESTING SUPPORT G = GUIDE F = AXIAL STOP B = ANCHOR M = SPRING S = TEFLON PAD
SUPPORT 2) PIPING INSULATION SPECIFICATION. 4240-XL-SG-00000000003. 6) SUPPORT SPECIFICATION. 4240-XH-SG-00000000002.
LIST NO WHERE A WITHOUT NUMBERING IS INDICATED, THIS MEANS THAT THERE IS A PLANT :- PARAXYLENE (PX)
3) TYPICAL INSTALLATIONS ENGINEERING SPECIFICATIONS. 4240-XH-SL-00000000011. 7) PAINTING SPECIFICATION. 4240-VW-SG-00000000003.
REST DIRECTLY ON STEEL STRUCTURE. 4) PIPING SPECIFICATION - PIPING PRESSURE TEST 4240-XH-SG-00000000004. 8) LINE LIST. 4240-XH-LL-00000000002. LOCATION :- PARADIP, ODISHA STATE, INDIA.
SIZE A3 SHEET 1 OF 1 REV. A