Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Aplisens PEM-1000

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Electromagnetic flowmeter HISPACONTROL S.L.

Pº Delicias 65 Bis

type PEM-1000 28045 Madrid


Tel. 915 308 552
hc@hispacontrol.com
O
Nominal size: DN10...1000 (ANSI 0,5...40“) www.hispacontrol.com
O
Maximum static pressure 1,6MPa, 2,5MPa or 4MPa
O
Accuracy: +/-0,5%
O
Analog outputs: 4...20mA,
O
Communication protocol: Modbus RTU / RS 485

Application
Electromagnetic flowmeter for bidirectional measurement
of liquids with a minimum conductivity of ≥5 ìS/cm:
• Acid, alkalis
• Paints
• Pastes
• Water, wastewater, etc.

Measuring principle:
Following Faraday's law of magnetic induction, a voltage
is induced in a conductor moving through a magnetic field.
In the electromagnetic measuring principle, the flowing medium PEM-1000ALW
is the moving conductor. The voltage induced is proportional
to the flow velocity and is supplied to the amplifier by means
of two measuring electrodes. The flow volume is calculated
by means of the pipe cross-sectional area.The DC magnetic
field is created through a switched direct current of alternating polarity.

Measuring system
The measuring system consists of a transmitter and a sensor.
Two versions are available:
• Compact version: Transmitter and sensor form a mechanical unit
PEM-1000ALW
• Remote version: Sensor is mounted separate from the transmitter
PEM-1000NW

Advantages
O
Flexible and clever assembling system
PEM-1000NW
O
Easy and fast-moving change from compact to remote version
O
Innovative and high-power transmitter for every application
O
Robust and resistant cover of sensor and transmitter

Flow value table in [ m3/h ] Standard set value Qmax


DN V = 0,3 m/s V = 1 m/s V = 3 m/s V = 5 m/s V = 8 m/s V = 10 m/s DN Flow [m3/h]
10 0,085 0,283 0,848 1,414 2,262 2,827 10 1
15 0,191 0,636 1,909 2,545 3,181 3,817 15 2
20 0,339 1,131 3,393 5,655 9,048 11,310 20 4
25 0,530 1,767 5,301 8,836 14,137 17,671 25 5
32 0,869 2,895 8,686 14,476 23,162 28,953 32 10
40 1,357 4,524 13,572 22,619 36,191 45,239 40 15
50 2,121 7,069 21,206 35,343 56,549 70,686 50 20
65 3,584 11,946 35,838 59,729 95,567 119,46 65 30
80 5,429 18,096 54,287 90,478 144,76 180,96 80 50
100 8,482 28,274 84,823 141,37 226,19 282,74 100 100
125 13,254 44,179 132,54 220,89 353,43 441,787 125 150
150 19,085 63,617 190,85 318,087 508,94 636,17 150 200
200 33,929 113,10 339,30 565,49 904,78 1130,0 200 360
250 53,014 176,71 530,14 883,57 1413,7 1767,1 250 500
300 76,341 254,47 763,41 1272,3 2035,7 2544,7 300 760
350 103,90 346,36 1039,1 1731,8 2770,9 3463,6 350 1000
400 135,72 452,39 1357,2 2261,9 3619,1 4523,9 400 1300
500 212,06 706,86 2120,6 3534,3 5654,9 7068,6 500 2000
600 305,36 1017,9 3053,6 5089,4 8143,0 10178,7 600 3000
800 542,87 1809,6 5428,7 9047,8 14476,4 18095,5 800 5000
1000 848,23 2827,4 8482,3 14137,1 22619,4 28274,3 1000 8000
Optimal flow speed – to 5m/s

VIII/ 2
Technical data
Specification for PEM-1000 control unit Specification for PEM-1000 sensor

Medium electrical conductivity 5m


3 S/cm Nominal size DN10¸ 1000 (ANSI 0,5”…40”)
Input resistance 31010W Max. static pressure
Accuracy ±0,5% of reading while flow in 20¸ 100% Qmax standard: 1,6MPa (2,5MPa, 4MPa on request)
±1,0% of reading while flow in 10¸ 20% Qmax Process connection flange DIN (ANSI, BS)
(for reference conditions)*
Ambient temperature -20¸
60°
C
Low flow rejection adjustable in steps of 0,1%
Liner temperature range Rubber: -5¸ 90°C
Actual flow 2-side (l/s,m3/h, m3/s, other)
Teflon: -25¸ 130°C
Totalizer 2-side (m3, other)
Connection cable standard: 8m (other on request)
Low flow automatic zeroing
Configuration buttons or RS485 and Modbus RTU Electrodes material 316L
(316Ti/Hastelloy/Tantalum/Titanium/Platinum)
Empty pipe detection cyclic, programmable
Flowtube material 321
Analog output 4¸20mA/500W
active output (passive output – on request) Liner Hard (or soft rubber) DN20¸ 1000
Pulse/frequency output max. 24V/10mA DC Teflon PTFE DN10¸ 500
0,1…500Hz in frequency mode; up to 500Hz in pulse mode Halar ECTFE DN350¸ 600
passive output, galvanic insulation, reverse polarity protection Casing and flange material standard : carbon steel
Communication output Modbus RTU/RS 485 (304, 321 on request)
galvanic insulation Rustproofing acrymetal paint
Binary input 5…35V DC/2mA Excitation coils supply from the transmitter
passive input, galvanic insulation, reverse polarity protection Excitation of coils isolation class E
Power supply 90..260V AC/50Hz/15VA
Protection class standard: IP67, (IP68 on request)
10…36V DC/15W (reverse polarity protection)
Protection class IP66 (IP67 on request) Measuring principle electromagnetic
Ambient temperature -20…60°C Accessories grounding rings
Weight 3,5kg

* Reference conditions according to PN-EN 29104:2003

Dimensions of control unit


159

213 194-213

VIII/ 3
Dimensions of sensor

Dimensions [mm] Weight

D1

2
DN PN A B D1 D2 d n kg

D
10 150 153 90 60 14 4 2,5
15 or 155 95 65 14 4 2,5
20 200 160 105 75 14 4 3
25 167 115 85 14 4 3,5
32 180 140 100 18 4 5
40 185 150 110 18 4 6
50 200 191 165 125 18 4 7
65 209 185 145 18 4 8


80 224 200 160 18 8 9,5
100 250 245 220 180 18 8 12

d
125 276 250 210 18 8 15
150 300 305 285 240 22 8 20
16
200 350 375 340 295 22 12 36
250 400 430 405 355 26 12 58
300 500 487 460 410 26 12 70
350 542 520 470 26 16 85
400 600 615 580 525 30 16 100
B+0,5
450 657 640 585 30 20 120
500 750 715 650 33 20 160
600 870 840 770 36 20 190
700 700 927 910 840 36 24 260
800 800 1050 1025 950 39 24 350
900 900 1145 1125 1050 39 28 450
1000 1000 1285 1255 1170 42 28 550 A

DN 10 – DN 150 A ± 5 mm
DN 200 – DN 1000 A ± 10 mm
Dimensions [mm] Weight
DN PN A B D1 D2 d n kg
10 150 153 90 60 14 4 2,5
15 or 155 95 65 14 4 2,5
20 200 160 105 75 14 4 3 Dimensions [mm] Weight
25 167 115 85 14 4 3,5 DN PN A B D1 D2 d n kg
32 180 140 100 18 4 5 10 150 153 90 60 14 4 2,5
40 185 150 110 18 4 6 15 or 155 95 65 14 4 2,5
50 200 191 165 125 18 4 7 20 200 160 105 75 14 4 3
65 209 185 145 18 4 8 25 167 115 85 14 4 3,5
80 224 200 160 18 8 9,5 32 180 140 100 18 4 5
100 250 245 235 190 22 8 12 40 185 150 110 18 4 6
125 276 270 220 26 8 15 50 200 191 165 125 18 4 7
150 300 305 300 250 26 8 20 65 209 185 145 18 4 8
25
200 350 375 360 310 26 12 36 80 224 200 160 18 8 9,5
250 400 430 425 370 30 12 58 100 250 245 235 190 22 8 12
40
300 500 487 485 430 30 16 70 125 276 270 220 26 8 15
350 542 555 490 33 16 85 150 300 305 300 250 26 8 20
400 600 615 620 550 36 16 100 200 350 375 375 320 30 12 36
450 657 670 600 36 20 120 250 400 430 450 385 33 12 58
500 750 730 660 36 20 160 300 500 487 515 450 33 16 70
600 870 845 770 39 20 190 350 542 580 510 36 16 85
700 700 927 960 875 42 24 260 400 600 615 660 585 39 16 100
800 800 1050 1085 990 48 24 350 450 657 685 610 39 20 120
900 900 1145 1185 1090 48 28 450 500 750 755 670 42 20 160
1000 1000 1285 1320 1210 56 28 550 600 870 890 790 42 20 190

VIII/ 4
Electrical diagrams

Terminal Description
12 13 14 Power supply
1
90...260V AC
(-) 10...36V DC
11 15 2 (+) (on request)
10
3 reverse polarity protection, galvanic insulation,
9

Binary output 1

POUPPL
4

S
passive
65 3 4

WE Y
R
5 reverse polarity protection, galvanic insulation,
87

21 Pulse/frequency output
6 passive
7 (+) active
Current output 4¸
20 mA (-)
8 (passive on request)
9 RS 485 A
10 RS 485 B
Communication
11 RS 485
GND / shield
Binary input (passive) 12
reverse polarity protection, galvanic insulation
13
14 reverse polarity protection, galvanic insulation,
Binary output 2
15 passive

Examples of installation

Ordering procedure

PEM-1000ALW /___-___/___/___/___/___/___

PEM-1000NW /___-___/___/___/___/___/___/ L =___ m


Nominal diameter: DN10...1000 Cable length (standard L=8m)
Pressure rating: PN16, PN25, PN40 Special version: IP68, IP67, SS, Qmax, PZH
Electrodes material: 316L, Power supply: 90...260 V AC, 10...36 V DC
316Ti, Hastelloy, Tantalum, Titanium, Platinum
Communication: Modbus RTU/RS 485
Liner material: hard rubber, soft rubber, Teflon, ECTFE

Special versions
IP68 – sensor protection class IP68 Qmax – non-standard value of Qmax.
IP67 – transmitter protection class IP67 PZH – approval for contact with potable water
SS – stainless steel sensor casing