Electromagnetic Catalogue
Electromagnetic Catalogue
Electromagnetic Catalogue
Model No.
UPCS-MAG-110
HSN CODE: 90261010
Technical Specifications
Sr.no. Parameters
1 Media : Liquids (Conductive)
2 Nominal dia (mm) : 15 to 3000
3 Working pressure : 10, 16, 25, 40 (Kg/cm²)
4 Working Temperature : 150°C for PTFE Lining & 85°C for Rubber Lining
5 Electrode material : SS 316L Std.* | HASTALLOY C | PLATINUM | TITANIUM | TENTALUM
6 Sensor Lining : Std. Rubber*/PTFE
7 Display Version : Integral/Remote
8 Measuring Tube material : SS 304 Std.*
9 Sensor housing material : Std. CS* | SS304 | SS316 optional
10 End connection : Flange/Wafer/Tri-clamp/SMS
11 Flange standard : ASA 150# | ANSI 150 | PN10 | PN16 | PN25 | PN40
12 Measuring range : 0.2 to 12m/sec. Bidirectional
13 Accuracy % of measured value : ±0.5% (±0.2% consult Factory)
14 Conductivity : Liquids (Conductive)
15 Repeatability : >5 μs/cm
16 Display : ±0.2% of Span
17 Display units : GRAPHIC DISPLAY/16X2 LINE DISPLAY
18 Output : 4-20 mA isolated / Modbus Rs485 / 4-20mA with HART Optional
: 1. 85-260 V AC
19 Power Supply Options : 2. 24V DC
: 3. Battery Operated
20 Protection Class for Sensor : Std. IP 65 | IP67 | IP68
21 Protection Class for Transmitter : IP66 | IP67 | IP68
22 Installation : Inline Flanged Type
ELECTROMAGNETIC FLOW METER UPCS-MAG-110
The Flux Density of the electromagnetic field in a given Flowmeter and the distance between the
electrodes are constant. Therefore, the induced voltage is only a function of liquid velocity.
E = KxBxVxD
0.0
m³/h
D : Electrode spacin
OD
Volume flow is calculated by the equation
Q=vxD²xπ/4
Therefore, W
ExDxπ
Q= FD
KxBx4
The induced voltage is not affected by the physical properties of liquids like temperature,
viscosity, pressure, density and conductivity as long as the conductivity of the measured
liquid is above the minimum threshold level. For reliable measurement, the pipe must be
completely full of the liquid. The electromagnetic field coil assembly is excited by pulsed DC
technique which eliminates the interfering noise and provides automatic zero correction.
FLOW RANGE
SIZE OD W H FD m³/hr LPM USGPM
(MM) (MM) (MM) (MM) (MM) Min Max Min Max Min Max
88.9 66 90 0.03 6.4 0.5 106.66 0.132 28.178
98.4 66 98 0.11 11 1.83 183.33 0.484 48.431
107.9 66 108 0.18 18 3 300 0.792 79.251
117.5 69 118 0.29 29 4.83 483.33 1.276 127.683
127 79 127 0.45 45 7.5 750 1.981 198.129
152.4 79 152 0.71 71 11.83 1183.33 3.126 312.603
177.8 79 178 1.19 119 19.83 1983.33 5.239 523.941
190.5 79 191 1.81 181 30.16 3016.66 7.969 796.919
228.6 108 229 2.83 283 47.16 4716.66 12.460 1246.011
254 106 254 4.42 442 73.66 7366.66 19.460 1946.067
279.4 155 280 6.36 636 106 10600 28.002 2800.223
342.9 171 343 11.3 1130 188.33 18833.33 49.752 4975.240
406.4 203 407 17.66 1766 294.33 29433.33 77.754 7775.464
450 240 483 25.43 2543 423.83 42383.33 111.964 11196.492
510 298 533 34.62 3462 577 57700 152.427 15242.727
570 336 597 45.22 4522 753.66 75366.66 199.097 19909.767
620 398 635 57.23 5723 953.83 95383.33 251.976 25197.610
675 450 700 70.65 7065 1177.5 117750 311.062 31106.259
785 550 813 101.74 10174 1695.66 169566.66 447.947 44794.774
ELECTROMAGNETIC FLOW METER UPCS-MAG-110
Installation Drawing
Inlet 0.0
m³/h
Ʃ+000000.000 m³
Oulet
5D 3D
Installation Precaution
Installation location should be such that the Flowmeter will always remain full of liquid.
Minimum 5D inlet & 3D outlet straight lengths should be maintained at installation locations where ‘D’ is
the pipe diameter.
The Flowmeter installation location should be free of bends, slbows, tees, valves, etc.
WARRANTY
All meter are warranted against any manufacturing
defect for a period of 12 months from date of supply,
provided the meter has not been misused, damaged,
installed for services it is not recomended or the seal
has been tempered with. The company shall be liable to
furnish part/ parts thereof or full water meter as the
company may deem fit.