Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Abacus LCD User Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 46

ABACUS

LCD User Guide

 Copyright. The copyright of this publication is the property of Detection


Systems and no part of its contents, shall be reproduced without the written
permission of Detection Systems.

Detection System’s Part Number D247-152 Issue 1 July 2000

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Introduction

The Abacus range of intruder alarm panels are manufactured by Detection Systems, using advanced
microprocessor technology, this allowing greater flexibility and ease of use. Whilst great care is taken
in its design, manufacturing and testing to provide you with many years of trouble free service. The
function of the Abacus panel is purely a detection warning system, and cannot guarantee you absolute
protection against burglary.

The Abacus panel can give a warning against Fire, but is not designed to comply with insurance or Fire
regulations. It should not be used in installations where a fire alarm system complying with those
regulations should be used.

This manual has been written to be as comprehensive as possible with brief explanations where
considered necessary. Detection Systems cannot be held responsible for system design or suitability of
the Abacus panel for a given installation. Any problems should they occur should be taken up with the
installation company.

Italics are used, in the text, to denote/indicate special differences between the Abacus panels and in the
index, to indicate main drawings, charts or lists.

When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator
instructions guide (Part No. Y6055).

For further information, contact your installation company

Abacus ……… Installed by………………………………….. Date…..…………….

Installation Company Address

…………………………………………………………

…………………………………………………………

…………………………………………………………

…………………………………………………………

Telephone Number …………………………………..

Service Contract ……………………………………..

Note. This manual has been written using the Abacus panels fitted with software Versions5215
and 7000/7016-(Abacus 6 Version 5400). Panels fitted with earlier or later software may
differ from operation description given. The history of some of the more relevant
changes that have been introduced since version 2100 (Abacus 6 version 4.5) have also
been included.

Detection Systems are constantly upgrading their systems in the light of introduction of
new standards, regulation changes, and changing market conditions.

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Contents
Chapter 1 - System Description

Page 1.1 General


System Features
Page 1.4 Power Supply
Page 1.5 Zone Circuit Types
Final Exit (FX)
Exit
Night
EX/FX
PA
Page 1.6 Fire
Part
24 Hour
Exit and Entry Times
Exit Time
Part Set Exit Time
Entry Time
Page 1.7 Alarm Times
Bell Ring Time
Bell Delay Time
Sounder Tones
Keypad Tone
Confirmation Tone
Chime Tone
Exit Tone
Part Setting Tone
Entry Tone
Alarm (Tamper or Bad Set) Tone
Page 1.8 Fire Alarm
System Detectors
Door Contacts
Movement Detector
Vibration Detectors
Personnel Attack
Fire Detectors
Auxiliary Detectors
Warning Devices
Page 1.9 Sounders
Bells
Strobes
Communicators
System Configuration
Area 1, 2 and 3
Common Area
Cleaner Area
Part Set
Page 1.10 Codes
Master Code
Main Code
On Off Code
Area 1, 2 or 3 Codes
Cleaner Code
Duress Code

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Page 1.11 Holder Code


Engineer Code
Keyswitch Control
Exit Terminator
Page 1.12 Installation Records List

Chapter 2 - Using the System

Page 2.1 General


Mode 1 Operation
Setting the System
Page 2.2 Part Setting the System
Page 2.3 Unsetting the System
Bad Set
Mode 2 Operation
Page 2.4 Setting the System
Page 2.5 Part Setting the System
Page 2.7 Unsetting the System
Page 2.8 Omitting Zones
Page 2.9 Reactivating Omitted Zones
Alternative Method of Reactivating Omitted Zones
Page 2.10 Attention Display
Quick Set/Help Keys
Keyswitch Operation
Page 2.11 Abort the Setting Routine
Reset the System
User Reset
Engineer Reset
Remote Reset
Page 2.12 Code Reset
Page 2.13 Setting Options Flow Chart
Unsetting Options Flow Chart

Chapter 3 – Programming

Page 3.1 General


Key Stroke Character Chart
Key Stroke Character Chart (Software Version 7000)
Page 3.2 Code Programming
Page 3.3 Delete a User Code
Page 3.4 Program Chime
Page 3.5 Programming the Date and Time
Page 3.6 Lock and Unlock Engineer Programming or Access via Modem
Page 3.7 Programming Flow Chart.

Chapter 4 – System Testing and Fault Indication

Page 4.1 General


Internal Sounder Checks
Zone Tests
Page 4.2 Zone Active Test
Bell Test and Sounder Tests
Page 4.3 Alarm Fault Display
Reading the Log
Page 4.4 Log information explained
Page 4.8 Quick Entry to the Log
Service Required
Page 4.9 Testing and Reading the Log Flow Chart

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Chapter 1 – System Description


General

The Abacus range of alarm systems consist of the following control panels:

Abacus 6R (metal panel) and Abacus 6P (polycarbonate with built in LED keypad).
Abacus 6/14 and Abacus 6/14 COM (metal panels).
Abacus 8R, (metal panel) Abacus 8P (Polycarbonate with built in LCD keypad) (Upgraded to
15P at Version 5015 software) and Abacus 8ABI (metal panel with built in LCD keypad).
Abacus 8/15P (Polycarbonate with built in LCD keypad), Abacus 8/80 (metal panel).
Abacus 15R, (metal panel).
Abacus 72R (metal panel).

All Abacus panels work in a similar way to each other, where they differ; the difference will be
indicated in Italics. Indication will also be given when new features were introduced.

Intruder alarm systems are individually designed for the premises; the system consists of a number of
component parts, some of which are manufactured by Detection Systems. This manual will describe
the Abacus panel operation in detail, but other components generally.

The main electronics that controls your alarm system is housed in the control panel. The Abacus 6P,
8P(15P), 8/15P and 8ABI control panels also contain an onboard Keypad. Abacus 6R, 6/14,
6/14COM, 8R, 8/80, 15R and 72R control panels require a remote keypad. All abacus panels can be
fitted with up to six (seven for Abacus 6R, 6/14, 6/14COM, 8R, 8/80, 15R and 72R) remote keypads.

The on board or remote keypads are the interfaces between you and your alarm system. You are able
to instruct the system on your requirements by pushing one or more of the twelve control keys. (1 to 9,
0/ESC, NO or YES/PART keys). The control panel will inform you of its status, by producing
different sounds, on the sounder, and giving text on the 32 digit LCD display (Abacus 6P only Coded
two digits on a LED display, see LED operators Guide). The two !! Keys on the remote keypads are
used as special function, i.e. as PA, Fire etc. Your installation engineer should inform you which
function is available on your system.

Your alarm system will have been divided into zones; each zone may be split into two circuits. The
circuits will have been programmed for a specific function. Your installation engineer should inform
you of the zone configuration of your system.

System Features

Features that vary between the panels are shown in the following table, and features that are common
to all panels, are listed after the table.

Feature↓Panel→ Abacus 6R/P Abacus 8ABI/R/P Abacus 15R/P Abacus 72R


Digits per code 4 4, 5 or 6 4, 5, or 6 4, 5, or 6
After ver 5000 4, 5 or 6
Letters per code 6 Upper case only 6 Upper/lower case 6 Upper/lower case 10 Upper/lower case
After Ver 5000 6 Upper/lower case
Number of codes 6 + Duress 15 15 99
After Ver 5000 15
Remote Keypads 6P = 6 LCD 8ABI/8P = 6 LCD 15P = 6 LCD 7 LCD
6R = 7 LCD 8R = 7 LCD 15R = 7 LCD
On board display 6P = LED 8ABI/8P LCD 15P LCD None
type 6R = None 8R = None 15R = None
Zones/ 6 zones/ 8 zones/ 8/ Exp to 15 zones/ 8/ Exp to 72 zones/
Circuits* 12 circuits 16 circuits 30 circuits 144 circuits
Text size 8 Upper case only 16Upper/lower case 16Upper/lower case 16Upper/lower case
After Ver 5000 16 Upper/lower

Chapter 1.1

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Feature↓Panel→ Abacus 6R/P Abacus 8ABI/R/P Abacus 15R/P Abacus 72R


Number of Areas 2 + Com 3 + Com + Clean 3 + Com + Clean 3 + Com + Clean
After Ver 5000 3 + Com + Clean
Event log 28 200+ 200+ 400+
After Ver 4.5 200+
Channel outputs 4 8ABI/P =4(ABI =7) 15P=7 15R=8 8
(Ver 5000) 8R = 7
Printer Available NO 8P=NO YES YES
8R/ABI=YES
Zone Trouble NO NO 15P=NO 15R=YES YES
Monitoring
Upload/download NO Before V 2200 NO Before V 2200 NO YES
(Ver ****) After V 2211 YES After V 2211 YES

Note. * Each zone can be split into 2 circuits using Stella PIR detectors or Zone splitters. Contact
Set and Chime functions will not work correctly on split zones.

Feature↓Panel→ Abacus 6/14 Abacus 6/14COM Abacus 8/15P Abacus 8/80


Ver 7000 Ver 7016 Ver 6015 Ver 7016
Digits per code 4, 5 or 6 4, 5 or 6 4, 5, or 6 4, 5, or 6
Letters per code 6 Upper/lower case 6 Upper/lower case 6 Upper/lower case 10 Upper/lower case

Number of codes 15 15 15 99

Remote Keypads 7 LCD 7 LCD 6 LCD 7 LCD


On board display None None LCD None
type
Zones/ 6/ Exp to 14 zones 6/ Exp to 14 zones 8/ Exp to 15 zones/ 8/ Exp to 80 zones/
Circuits* 28 circuits 28 circuits 30 circuits 160 circuits
Text size 16Upper/lower Case 16Upper/lower case 16Upper/lower case 16Upper/lower case
Number of Area 3 + Com + Clean 3 + Com + Clean 3 + Com + Clean 3 + Com + Clean
Event Log 200+ 200+ 200+ 400+
Channel Outputs 4 3 7 8
Outputs 4/20 4/20 4 4/20
Printer Available NO NO YES YES
Zone Trouble NO NO NO YES
Monitoring
Upload/download NO YES YES YES
Point ID YES YES NO YES
SIA NO NO NO YES

All Zones / Circuits are individually programmable. (Engineer)

Tamper on all zones.

Chime function is programmable for any zone.

ET button also gives chime (may be used as a doorbell).

Area Setting and Part set of areas.

On board keypad models, have Quick set facility for Part Set, Full Set and Chime setting.

Remote Keypad !! keys, programmable for either PA, Fire, Medical, Chime, Part or Full set.

Optional Key-switch, to Part and Full set the installation or areas.

Chapter 1.2

www.PDF-Zoo.com
Detection Systems Abacus User Guide

At Ver 4500 for Abacus 6P/R and Ver 2100 for Abacus 8ABI/8P/8R and Abacus 15R the main software
changes are:

The Area previously known as System is now called Area 1, Area 1 becomes Area 2, and Area
2 becomes Area 3(not available on Abacus 6P/R).

Single code entry on setting after or on Mains Failure.

New way of software numbering introduced and displayed for the Engineer.

At Ver 4600 for Abacus 6P/R and Ver 2200/2211 for Abacus 8ABI/8P/8R and Abacus 15R the main
software changes are:

West Midlands Police request Exit Terminate is required for both Part and Full Set
introduced (before this version Exit terminate was for full set only).

Ver 2211 software also introduced the capability of Upload/Download.

Abacus 72R introduced with Version 2313 with two modes of operation for area settings, Mode 1 or
Mode 2.

Abacus 72R Version 2713 introduced the following changes:

Relay output switched for 16 second when programmed to any code by the Engineer.

Main or Duress codes can now be programmed for specific areas.

On timed Exit or Exit terminate (not contact set) the entry time is doubled when entry is by a
FX detector on a zone Circuit B. (Zone Circuit A entry time is as programmed).

Communicator programming added to be able to program the Talk-DAC.

At Ver 5000/5015 for all Abacus panels the main software changes are:

Time changed from 24-hour clock to AM/PM.

All panels can now operate with 2 modes of Area settings, Mode 1 or Mode 2.

Improved log and log search facility.

Main or Duress codes can now be programmed for specific areas.

NO key on keypad 5 may be used as an Exit Terminator in part set.

First zone to alarm displayed in part set before entering the code.

Chime zone displayed for duration of chime tone.

Engineer can program the area description that is displayed in Mode 2 setting.

New Keyholder code introduced.

At Ver 5300 for Abacus 6P/R and Ver 5115 for all other Abacus panels, the software now records the
user chime programming state so they are retained in case of a total power failure.

At Ver 6000/ 6015 for all Abacus panels, programming for ADV1 communicators introduced.

Chapter 1.3

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Version 7000 software was introduced with many new features (see below) and new design of PCB’s to
enable use of the keypad bus for expansion, by using I/O modules and communication of signals using
the new ADV1 additional features. As the Abacus 8/15P can only be fitted with a 3.2A battery
additional power required and size of panel limited the introduction of Version 7000 features. (I/O
Modules not fitted or Point ID is not available on Abacus 8/15P).

New On/Off user code introduced.

Separate Exit times for areas.

Improved part setting of areas.

Increased display time on pressing YES/PART key after alarm and code on coded reset.

Improved use of text with a library.

New menu, to warn you, that you are about to enter programming/omit routines.

New menus to allow faster access to code programming etc (i.e. ‘Enter code No.’ to enable
you to select the code you require to change).

Duress code area setting option removed (Duress is now all areas).

When panel is set strobe operates for five seconds to indicate panel set.

Sounder is no longer activated with ‘Engineer read log’ displayed.

Unused zones may be disabled by programming.

Zone six may be used for silent signalling on point ID or SIA (Abacus 8/80)

Improved Factory Default Settings.

On alarm display reads as appropriate either Phone Engineer or Phone ARC (Alarm
Receiving Centre).

Engineer can also reset panel on coded reset.

Improved Upload/Download programming functions.

Upload/Download log can now be programmed for pre-set number of events before
downloading.

Mode 1 operation, no longer available.

Silent Set Normal/ Low conformation tone volume setting.

SIA protocol introduced on Abacus 8/80.

Power Supply

Caution. Should you become aware that power is to be removed for a prolonged period, then
contact your installation engineer.

All Abacus panel are supplied with power from the mains, which should not be switched off. Within
the panel is an emergency battery that is on float charge. Should the mains power be lost the battery
will support the system for at least eight hours. If mains remain off for over eight hours, the system
could go into an alarm condition, and you will be unable to silence the outside bell. The battery could
also be damaged by going into deep discharge and require replacement. (Abacus 72 and Abacus 8/80
have a battery cut of relay to prevent deep discharge).

Chapter 1.4

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Zone Circuit Types

Final Exit (FX)

At least one of the zones circuits on your alarm system will have been programmed as a final exit (FX).
A FX detector is the last detector, on the exit route from the keypad that is operated on leaving the
alarmed premises. It is also the first detector to be activated on entry to the alarmed premises.

If the FX circuit is closed by locking the access door, it may be used to terminate the exit routine and
finally set the system (Shunt lock). This may be the way that your system has been designed to comply
with ‘Association of Chief Police Officer’ (ACPO) intruder alarm policy.

The prime purpose of the FX circuit is that, when the installation is set, on activation of the FX detector
the entry routine is started. This starts the entry warning sounder, and allows time to reach the keypad.
The user can then unset the system without generating an alarm. If this time is exceeded, a full alarm is
generated. If a communicator is fitted, the panel signals an intruder alarm to your central station.

Note. Your system may be programmed that on setting, if the FX detector is not seen to close then
the system will only part set. This means that to do a full set you must leave the protected
location.

Exit

Zones circuits located on the exit/entry route are described as exit route detectors, these detectors,
during both entry and exit, are disabled for the programmed time of the exit/entry periods. Only when
the installation is set, will they generate a ‘full’ alarm.

Night

Detector circuits configured as night (NITE), when activated, will generate a ‘full’ alarm when the
panel is set or in the entry mode. The detector, when active in the exit mode will generate a ‘bad set’
fault condition. The detector will be inactive in the unset mode.

EX/FX

Detector circuits configured as Exit/ Final Exit (EX/FX) will work as an Exit detector when full set, or
as a FX detector in Part Set.

PA

A detector circuit programmed as a Personnel Attack (PA), when activated, regardless of panel setting
will initiate one of the following:

1. Ring bells, sounders and activate strobe, will also signal, if communicator fitted, to a
central station.

2. Ring bells, sounders and activate strobe.

3. Silent, communicator signals to a central station only.

4. Fault audible. Normally silent, communicator signals to a central station but on a line
fault condition the PA activation will ring bells, sounders and trigger the strobe.

Your installation engineer should inform you of, or enable the PA mode you require.

Chapter 1.5

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Fire

This parameter is programmed to a zone circuits that has fire detectors connected. When activated,
(regardless of panel setting states), it will instantly generate a fire warning, by pulse switching the bells
and sounders. If a communicator is fitted, it will signal to central station a fire signal.

Part

Part is a secondary programming to zones circuit programmed as Exit or Nite, in the Set mode they
work as described above. When the panel is Part Set any Exit or Nite circuit also programmed as Part
will be omitted.

24 Hour

This zone circuit type is programmed to a circuit that requires to generate a full alarm, (signal an
intruder alarm and ring bells etc) when the panel is set, and generate local alarm when panel is unset,
(internal sounders only). A typical use for this type of circuit is a fire escape door.

Exit and Entry Times

These times are set up by your installation engineer to give you time to safely operate your Abacus
alarm system.

Exit Time

Note. On communicating systems, the policy of some police forces is that exit timers are not
permitted, and the exit time is terminated by a setting push or shunt lock. Should your system
be installed in one of these area’s, your installation engineer will advise on your method of
final setting.

The exit time (1 to 99 seconds or continuous until setting signal is received) is set to give you time to
leave your premises. On entering the users code (factory Default is 1234), the exit timer is started, and
a warning sound is given to tell you to leave the protected location. The warning sounder is terminated
when the protected location is set. You are strongly advised to wait outside the protected location for
the sounder to stop, as conformation that the system is set.

Part Set Exit Time

The part set exit time is set for either (your installation engineer will have selected which):

1. Silent, on selecting part a timer is started (no setting warning produced) a short sounder
tone is given at the end of the exit to confirm Part Set.

2. Audible, on selecting Part the timer is started and a setting warning sounder operated, at the
end of the time programmed the sounder stops to confirm Part Set.

3. Either a pre-set time of 30 Seconds, or time as normal exit or exit terminator setting will
have been programmed to work with above silent or audible. Part Set options.

Note. When setting, if the panel is unable to set it will produce a ‘Bad Set‘ tone and give the
appropriate indication.

Entry Time

The entry time (1 to 99 seconds) is set to give you time to enter the protected premises, and unset the
Abacus system, without generating a false alarm. On activating the FX detector (or EX/FX in part set)
the warning timer is started and is terminated by entering the user code. If the user code is not entered
in the given time or you stray off the access route then an intruder alarm is generated.

Chapter 1.6

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Alarm Times

Bell Ring Time

In case of an Alarm (All Types), your Bell and internal sounders will sound for this time (1 to 99
minutes or continuous).

Note. Local Authority Noise and Pollution Act 1974. Noise ---- limited to a maximum of 20
minutes.

Bell Delay Time

This is the time in the range of 1 to 99 minutes or no delay after, an intruder alarm has been signalled,
before local indication is given by activating Bells Sounders etc. Your local police may state a
requirement for this setting.

Sounder Tones

The Abacus panel will generate different frequency; duration and volume of tones to indicate various
warnings to you as you operate the system.

Keypad Tone

Each time a key is pressed, a confirmation keypad tone is produced. – A short bleep at low volume.

Confirmation Tone

A 1 second bleep is given as a confirmation tone at normal (as exit tone setting) or low volume (i.e.
panel silent Part Set confirmation – version 7000 software).

Chime Tone

A tone of pulses is produced for 2 seconds when an Exit Terminator (doorbell) is pressed, or a zone
that you have programmed to chime, is activated when unset. At a volume set by the installation
engineer.

Exit Tone

When the exit timer is running a continuous warning tone is produced. If an exit zone detector is
activated the tone is pulsed until detector is clear. The volume is as set by the installation engineer.

Part Setting Tone

When the entry timer is started, a slow pulsed warning tone is produced. The volume is as set by the
installation engineer.

Entry Tone

When the entry timer is started, a fast pulsed warning tone is produced. The volume is as set by the
installation engineer.

Note. The engineer sets the volume for Chime, and Exit and Entry tones.

Alarm (Tamper or Bad Set) Tone

When an alarm tone is required, the Abacus panel generates, at full volume, a warbling tone, until
either, a valid code is entered, or bell ring time expires.

Chapter 1.7

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Fire Alarm

Same signal as alarm, but pulsed switched ON for 1 second and OFF for 1 second.

System Detectors

An intruder alarm system is built up of a number of detectors (Many manufactured by other


companies) wired into the Abacus control panel zones; these detectors are selected for the type of
detection required and the environment of the location. Listed below is a number of the more common
type of detectors used.

Door Contacts

A set of magnetic contacts (switches) installed on a door (or window) which will signal to the Abacus
panel when the door (or window) is opened.

Movement Detectors

A security device normally mounted at head height to detect the movement of a person within a given
location (i.e. the lounge). These detectors use one or more technologies such as passive infra red,
microwave or ultrasonic principles.

Vibration Detectors

A small sensitive security detector fitted to a door/window frames etc., to detect vibration caused by
forced entry.

Personnel Attack

A push button type switch, strategically positioned within the premises, when operated regardless of
whether the panel is set or unset will signal a personnel attack alarm (PA) to the central station if a
communicator is fitted. The PA alarm may be silent alarm or a full alarm (bells and sounders) as
programmed by your installation engineer.

Fire Detectors

A fire detector is a device that will operate on detection a fire (i.e. smoke or heat detector). These
devices, when activated, will cause the Abacus panel to give distinct fire alarm signal. This signal is
generated by the panel continually pulsing all sounders and bells (1 second on and 1 second off).

Caution. The Abacus control panel has not been designed to comply with the fire industrial
standards and should not be used when an approved fire panel is recommended or
required. Detection System cannot be held responsible for any failure to comply with
any fire industry requirements, or relevant standards or regulations.

Auxiliary Detectors

The Abacus panel can accept signals to give a warning from other forms of detectors such as a freezer
temperature alarm, flood alert alarm or gas alarm (i.e. Carbon Monoxide), when triggered the system
will give an internal alarm only, and remote signalling, if programmed and communicator fitted.

Warning Devices

The most important function of any alarm system, is to quickly inform that an event has occurred, this
is done in a number of ways.

Chapter 1.8

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Sounders

Sounders are used as internal warning devices, to indicate a range of events that have, or are taking
place. (See sounder tones earlier in this chapter).

Bells

This is an external warning device, (this could also include a siren), to inform the neighbourhood that
an event has occurred and help may be required. (See also Alarm times earlier in this chapter).

Strobes

Strobes (flashing lights) are used to give a visual indication for quick identification of the location of an
alarm, very useful in shopping centres etc..

Communicators

A device used to communicate between the alarmed premises and a remote location such as a central
station. Communicator can take the form of digital communicators, which dial to the central station
and pass the relevant alarm information. Red Care systems that are continually monitored and change
the signal conditions to signal alarm states to the central station. VODASSURE an AB-NET
communicator signalling the alarm conditions over the PAKNET radio data network to a central
station. The central stations are manned 24 hours a day 365 days a year, on receipt of an alarm,
evaluate the messages received and call out the appropriate services. (I.e. The keyholder, Police or Fire
Services).

System Configuration

The system is built up of a number of zones, these zones may have been split into two circuits to aid
recognition and fault finding. The zones/circuits may then be arranged to work in specific areas such
as in a factory, to enable the office, workshops and stores to be controlled separately.

Area 1, 2 and 3

The Abacus panels can operate with up to 3 areas plus a common and cleaner area (See System
Features for your panel). This allows the system to have individual areas set from specific area codes.
If the installation engineer have set the panel to mode 2 (version 5000 or later), then the main or
master codes can set/unset a specific area. Whenever areas are used, an individual code must be
available for each area.

Common Area

A zone programmed as common, is common to all areas, therefore is set when the last area is set, and is
unset when the first area is unset (i.e. The common area is unset when any one or more areas are unset).

Cleaner Area

In some locations, an individual may require to unset zones in several areas. (I.e. a Cleaner or
Security Guard is required to unset all the corridors but not the offices). This function can be
undertaken by a cleaner code, when entered in the unset mode only displays ‘Cleaner on Site’ but when
set, Unsets all zones programmed as cleaner, on re-enter of cleaner code, Sets all zones programmed
as cleaner. Other codes can override this function (i.e. An area code when used to set an area, is
requested ‘Cleaner on site ok?’ – if replied NO then panel sets all zones in that area, if replied YES
then panel sets those zones not programmed as cleaner in that area). (See System Features).

Part Set

Zones in each area can be programmed as part, which on part setting the area or installation will be
omitted. An example of this is the bedrooms, at night you can part set the installation and go to the
bedroom without the bedroom detector causing an alarm.

Chapter 1.9

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Codes

There is a variation of user codes available each with a greater or lesser access and control over the
installation. (See System Features for number of codes and digits available).

Master Code

The master code can operate and program all the user function available on the Abacus panel as listed
below:

Program and remove all user codes.


Program the date and time, and chime function.
Allowing the engineer or remote modem access to engineer functions.
Read the log events.
Test the System (Except for active zones).
Can Set, Part Set and Unset all areas.
Can isolate or omit areas and certain zones.

Main Code

The main user code has the same function as the master code, except that it is unable to program or
remove codes, or change the engineer lock/ unlock function.

On version 5000 software or later, the master code user can limit the area access available to the main
user code holder.

On Off Code

The On Off code, introduced at version 7000 softwarw, Sets, Part-Sets and Unsets all areas. It cannot
omit any zones or change any program functions.

Area 1, 2 or 3 Codes

An area code holder is only able to Set, Partset or Unset that specific area. (i.e. Area 2 code sets/unsets
Area 2) The area code cannot omit zones or control other function on the system.

Cleaner Code

See system features for availability on your installation.

A code programmed as cleaner is used to unset specific zones in several areas (I.e. a Cleaner or
Security Guard is required to unset all the corridors but not the offices). When entered in the unset
mode only displays ‘Cleaner on Site’ but when set, unsets and Sets all zones programmed as cleaner.
Other codes can override this function (i.e. An area code when used to set an area is requested
‘Cleaner on site ok?’ – if replied NO then panel sets all zones in that area, if replied YES then panel set
those zones not programmed as cleaner in that area).

Duress Code

This is a special code that will set, part set or unset all areas. BUT first it signals a duress signal to
central station (a silent personal attack to alert the alarm monitoring service that the system is being
Set/Unset under duress).

On version 5000 software, the master code user can limit the area access available to the Duress user
code. On version 7000 software duress code is again for all areas.

Chapter 1.10

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Holder Code

This is a special code introduced at version 5000 software for issue to security guards etc.

When the panel is Unset the holder code works the same as a main code. It enables the user to
investigate the log, omit zones and set the installation. Once the installation is set the holder code
cannot normally unset it, Should an alarm be generated, then four minutes after the alarm signal has
been sent the holder code can be used to unset the installation. This enables the holder code user
(security guard) with the police to investigate the cause of an alarm.

Engineer Code

The engineer’s code enables the engineer to change the panel parameters (i.e. how each zone functions
and is displayed). This code can be used to set and unset the installation, to enable the engineer to
perform tests without the need to know the user codes. However, the user can prevent the engineer
from changing program function, without first unlocking the system. (See ‘Engineer Lockout’ in
chapter 3).

Note. Although the engineer code can set and unset an installation it cannot unset an installation
that has been set by a user code. If an installation has been set by an engineer code any user
code can be used to unset as appropriate.

Only the engineer code can change the engineer code, the engineer code cannot change any of
the user codes. The master code is the only code that can change user codes.

Keyswitch control

A keyswitch may be wired to an Abacus control panel, to enable the user to set, unset or part set the
installation or a specific area. When a keyswitch is fitted and used on an area, then an area code for
each area must also be programmed. User codes override the keyswitch function therefore the
keyswitch may require to be re-aligned to the Abacus state before it will re-function.

Exit Terminator

A push button may have been fitted to your system to finally terminate the setting exit routine, when
setting you push this button and check that the exit sound stops before leaving the installation. An exit
terminate button also doubles as a Doorbell.

The NO key on keypad number 5 may be used as the exit terminate in part set. (Version 5000 or later).

Chapter 1.11

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Installation Records List

Zone Name Zone Type Continuity Insulation Volt Drop Notes


01

02

03

04

05

06

07

08

09(11)

10(12)

11(13)

12(14)

13(15)

14(16)

15(17)

(18)

Continuity Insulation Notes


Keypad Bus

Bell cable

Speaker

Voltage Current Notes


Mains

Battery
Charge
Battery Load

System Batt ch + load

Time Notes
Entry Time
Seconds
Entry Delay
Seconds

Chapter 1.12

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Time Notes
Exit Time
Seconds
Exit Delay
Seconds
Bell Delay
Minutes
Bell Ring
Time Minutes
Programmed
Remote
keypad ! keys
PA (Silent ?)

Reset Mode

Location
Area(s)

Exit
Terminator
Keypads

Keyswitch

Central
Station
Address
C/S Tel No.

Service
Engineer
Address
S/Eng.
Tel No.

The above table has been given to enable a record to be made of your installation by the engineer, and
to be of use when servicing is carried out. (Your installation company may use another method in
place the above chart for their records). Please fill in as completely as possible, using the blank
sections to record additional items. For systems above 16 zones, make up your own similar format
record sheets. (The Abacus 72 and Abacus 8/80 format is shown in brackets above).

Chapter 1.13

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Chapter 2 Using the System


General

The Abacus system is controlled from the keypad, if more than one keypad is fitted any keypad can be
used. If a keypad is currently in use, the remainder of the keypads will display ‘please wait’. You instruct
the Abacus system on your requirements by pressing one or more of the twelve control keys. (1 to 9,
0/ESC, NO, or YES/PART). The control panel will inform you of its status in plain abbreviated language.
(Abacus 6P, panel display, two-digit seven-segment LED display codes. See user guide DS Part No.
Y6055) The two ! Keys on the remote keypad are available as special function keys. E.g. Fire, PA or
medical etc, (Check with your installation engineer).

The operation of the system is aided by the messages (up to 32 digits) displayed. On using the system,
press the YES/PART key to accept display indication, or number key indicated, or NO key to
change/request next option.

The factory Default of the Master code is 1234, you are advised to change this code as one of your first
operations of the systems (see Chapter 3).

Mode 1 Operation

If area settings are used, the engineer will have set the system for one of two ways of setting, Mode 1
(Discontinued at version 7000 software) or Mode 2, (when using the master or main codes). Mode 2
operation is only available on all Abacus 72 panels and all Abacus panels with Version 5000 software or
later. If area setting is not used follow mode 1 operation.

Setting the System

From the day mode: Ensure protected location is secure, detectors are
not obstructed, people and pets have left the
area.
0712 03:46P
System Off Display shows typical display, if programmed
the time and date may be replaced by a
company name (Ver 5000 software).
Enter the User code (1234).
Enter any user code, they operate for there
specific area(s) (see code type chapter 1 and
Hello XXXXXX code programming chapter 3).
Set System?
If programmed X’s indicate user name or is left
blank.
Press the YES/ PART key.
Press the YES/PART key (or wait 20 seconds)
to start setting or 0/ESC key to abort.
Setting ok!
Please leave… Panel now starts the setting procedure, sounds
the exit sounder to advise you to leave via the
exit route. Enter user code to abort setting.
Leave the protected location lock the door and
press the Exit Terminate button (if fitted). Panel stops the sounder on completion of setting
Ensure that the sounder stops before leaving the to inform you that all is correct for you to leave.
premises.
When the panel is set the display will indicate
0712 03:47P SET that state, if areas are used, it indicates the area
Area 1 set. As shown below all 3 areas and cleaner
area Set.
The protected location is now set.
0712 03:47P SET
Area 1 Clnr A2 /3

Chapter 2. 1

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Note. The final setting may be by an Exit Terminator, a contact on your final door lock, or a pre
programmed time. Your installation engineer will confirm your method of final setting.

If installation fails to set, see Bad Set page 2.3.

Part Setting the System

From the day mode:

Display shows typical display, if programmed


0712 03:46P the time and date may be replaced by a
System Off company name. (Ver 5000 software)

Enter any user code, they operate for there


Enter the User code (1234). specific area(s) (see code type chapter 1 and
code programming chapter 3)

Hello XXXXXX If programmed X’s indicates user name or is


Set System? left blank.

Press the YES/ PART key. Press the YES/PART key to start setting or
0/ESC key to abort.

Setting ok! Panel now starts the setting procedure, sounds


Please leave… the exit sounder to advise you to leave via the
exit route. Enter user code to abort setting.

Press the YES/ PART key. Press the YES/PART to part set the
system/area.

P/Setting ok! Panel stops the sounder on completion of


Please leave… setting to inform you that all is correct for you
to leave.

Press the YES/ PART key again if silent part On some installations part/set may have been
set is required. programmed to be silent, in this case the
S/Setting screen is displayed, and panel silent
part sets and gives a confirmation set tone.
S/Setting ok!
Please leave… When the panel is set the display will indicate
that state, if areas are used, it indicates the area
set. As shown below all 3 areas and cleaner
Leave the protected location; press the Exit area are Part Set.
Terminate button (if fitted). Ensure that the
sounder stops or confirmation tone is received.
0712 03:47P SET
Area 1 Clnr A2 /3
0712 03:47P SET
Area 1
If installation fails to part set, see Bad Set page
2.3.
The protected location is now part set.

Note. Your installation may always-silent set for Part set, the final setting may be by deactivation of
a detector programmed as EX/FX, an Exit Terminator, or a pre programmed time. Your
installation engineer will confirm method used on your installation.

On some installations, Exit Terminate for part set may be the NO key on keypad number 5.

Chapter 2. 2

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Unsetting the System

The procedure to unset the installation is the same regardless of it being Set or Part Set.

Enter the installation via the correct entry route As the point of entry detector is activated the
and proceed to the keypad. entry timer is started, to give you time to go
direct to your keypad and unset the
installation. At the same time, an entry
0712 03:47P SET
warning sounder is activated.
Area 1 Clnr A2 /3

Enter the user code (1234). On entering the user code, the sounder will
stop and you are free to enter the protected
location.
0712 03:47P
System Off If your installation as been divided into area’s
and a area code was used, then only that area
has been unset, the display will indicate which
The installation is now unset. areas that are still set. DO NOT ENTER
THOSE AREAS.

0712 03:47P SET


A2 /3

Display above indicates that Area 1 is unset,


and both Area 2 and Area 3 are still set. You
are free to enter Area 1, but should you enter
Area 2 or Area 3 a full alarm will be generated.

To unset the remaining areas repeat the above procedure using the appropriate code.

Note. Main or Master codes will unset all areas, whilst an area code will only unset its own area.

Bad Set

Should the installation fail to set, because a detector is in an alarm condition etc., a Bad Set tone will be
sounded whilst setting the installation. If this happens return to the keypad and read the display.

Enter your code to silence the sounder and clear the fault indication.
Bad . . SET 02A
Hall Door
Correct the fault indicated. In this case close and secure the Hall Door.

Enter your code to repeat setting of the installation.

If unable to clear fault, see chapter 4 or telephone your installation engineer. THE INSTALLATION
IS NOT SET.

Mode 2 Operation

If area settings are used, the engineer will have set the system for one of two ways of setting, Mode 1 or
Mode 2, (when using the master or main codes). Mode 2 operation is only available on all Abacus 72
panels and all Abacus panels with Version 5000 or later software. If area setting is not used follow
mode 1 operation. Version 7000 software only has mode 2 operation available.

Chapter 2. 3

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Setting the System

Ensure that the protected location is secure, detectors are not obstructed, people and pets have left the
protected area/s.

From the day mode:


Display shows typical display, if programmed
0712 03:46P the time and date may be replaced by a
System Off company name.

Enter the Main or Master User code (1234). Enter either a main or master user code, The
main code may have been limited to specific
area(s) (see code programming chapter 3).
Hello XXXXXX
Set System?
If programmed X’s indicates user name or is
left blank.
Press the YES/ PART key.
Press the YES/PART key to start setting or
0/ESC key to abort.
Setting 123 ok!
Please leave… Panel now starts the setting procedure for all 3
areas, sounds the exit sounder to advise you to
Leave the protected area or press the NO key leave via the exit route. Enter user code to
to select the Area(s) required to set. abort setting.

If the NO key is not pressed, the system will


SET Area 1? carry on setting all areas whilst you leave the
Workshops premises, the panel stops the sounder on
completion of setting procedure to inform you
Press YES/PART or NO key as required. that all is correct for you to leave.
(NO)
On pressing the NO key, the setting routine is
SET Area 2? stopped until the appropriate areas have been
Offices selected or deselected by pressing the
YES/PART or NO keys as each area is
Press YES/PART or NO key as required. displayed.
(NO)
Example shows not selecting setting of Area 1
SET Area 3? and Area 2.
Stores
The area descriptions (workshops, offices and
stores) will be change to as programmed by the
Press YES/PART or NO key as required. engineer for your installation.
(YES)
Example shows selecting of setting Area 3.
Setting 3 ok!
Please leave Example shows Area 3 now setting.

Leave the protected area(s) lock the door and When the panel is set the display will indicate
press the Exit Terminate button (if fitted). that state i.e. A3 = Area 3 set. Also shown
Ensure that the sounder stops before leaving below all 3 areas and cleaner area is Set.
the location.
0712 03:47P SET
0712 03:47P SET Area 1 Clnr A2 /3
A3

The protected location/area(s) is/are now set.

Chapter 2. 4

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Note. For user area codes follow the instructions for mode 1.

If installation fails to set, see Bad Set page 2.3.

Part Setting the System

Ensure that the protected location is secure, detectors are not obstructed, people and pets have left the
protected area. People/pets etc. may be in the Part Set location (i.e. bedrooms).

From the day mode:

Display shows typical display, if programmed


0712 03:46P the time and date may be replaced by a
System Off company name.

Enter either a main or master user code. The


Enter the Main or Master User code (1234). main code may have been limited to specific
area(s) (see code programming chapter 3).

Hello XXXXXX If programmed X’s indicates user name or is


Set System? left blank.

Press the YES/ PART key. Press the YES/PART key to start setting or
0/ESC key to abort.

Setting 123 ok! Panel now starts the setting procedure for all 3
Please leave… areas, sounds the exit sounder to advise you to
leave via the exit route. Enter user code to
abort setting.
Press the YES/ PART key to part set all areas
or NO to select the area to part set. (NO) X If the YES/PART key is pressed the panel will
now Part Set all areas.

P/Setting ok! Press the YES/PART key again, the system


Please leave… will silent part/set all areas.

The system will carry on part setting whilst


Press the YES/PART Key to silent part set if you leave the premises, the panel stops the
required. sounder on completion of setting or gives a
conformation tone to inform you that all is
correct for you to leave.
S/Setting ok!
Please leave…

X On pressing the NO key, the setting routine is


stopped until the appropriate areas have been
selected or deselected by pressing the
SET Area 1? YES/PART or NO keys as each area is
Workshops displayed.

Press YES/PART or NO key as required.


(NO)

Example shows not selecting setting of Area 1


SET Area 2?
and Area 2.
Offices

Chapter 2. 5

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Press YES/PART or NO key as required. The area descriptions (workshops, offices and
(NO) stores) will be change to as programmed by the
engineer for your installation.

SET Area 3?
Stores

Press YES/PART or NO as required. (YES) Example shows selecting of setting Area 3.

Setting 3 ok! Example shows Area 3 now setting.


Please leave

Press the YES/ PART key. Press the YES/PART key to Part Set the area/s
selected.

P/Setting ok! The system will now start Part Setting, leave
Please leave… the area, the system will part set either on
pressing the Exit terminator button, (This may
be the NO key on keypad number 5)
Press the YES/ PART key again for silent part deactivation of a detector programmed as
set. EX/FX or on the Exit timer expiring.

On some systems, the engineer may have


S/Setting ok! programmed part setting to always be silent in
Please leave… Part Set, in that case the previous stage may
be omitted.

Leave the protected area(s) and press the Exit When the panel completes the silent Part/Set, a
Terminate button (if fitted). Ensure that the confirmation tone will be given.
sounder stops before leaving the location.
When the panel is set the display will indicate
that state i.e. A3 = Area 3 part set. Also shown
0712 03:47P SET below all 3 areas and cleaner area are Part Set.
A3
0712 03:47P SET
Area 1 Clnr A2 /3
The protected location/area(s) is/are now part
set.

Notes. For user area codes follow the instructions for mode 1.

The instructions given here will vary slightly dependant on the number of areas on your
installation and also the set state of your system.

If installation fails to part set, see Bad Set page 2.3.

Chapter 2. 6

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Unsetting the System

The procedure to unset the installation is the same regardless of it being Set or Part Set.

Enter the installation via the correct entry route As the point of entry detector is activated the
and proceed to the keypad. entry timer is started to give you time to go
directly to your keypad and unset the
installation, at the same time an entry warning
0712 03:47P SET sounder is activated to remind you to unset the
Area 1 Clnr A2 /3 system.

Enter the Main or Master code (1234). On entering the user code, the sounder changes
tone to remind you that you have further
questions to answer.
UnSet ALL Areas?
You now go through a process of telling the
installation which areas you require to unset.
When you have completed the routine, the
Press the YES/PART key to unset ALL areas display will indicate which areas that are still
or NO key to select Areas. (NO) set. DO NOT ENTER THOSE AREAS.

UnSet Area 1 ? 0712 03:47P SET


Workshops A2 /3

Press YES/PART key to unset area 1 or NO Display above indicates that Area 1 is unset,
key to leave area 1 set. both Area 2 and Area 3 are still set. You are
free to enter Area 1, but should you enter Area
2 or Area 3 a full alarm will be generated.
UnSet Area 2 ?
Offices

Press YES/PART key to unset area 2 or NO


key to leave area 2 set.

UnSet Area 3 ?
Stores

Press YES/PART key to unset area 3 or NO


key to leave area 3 set.

0712 03:47P
System Off

The installation is now unset.

To unset the remaining areas, repeat the above procedure or use the appropriate area code and follow
the instructions for Unsetting in mode 1.

Notes. Main or Master codes will unset all areas, whilst an area code will only unset its own area.

The instructions given hear will vary slightly dependant on the number of areas on your
installation and also the set state of your system.

Chapter 2. 7

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Omitting Zones

Using the main or master codes it is possible to omit areas or zones providing this facility has been
programmed by your installation engineer. Omitting, if available, can be done when setting the
installation or on zones that are normally active when unset, i.e. a fire detector, in the loading bay, to
prevent a false alarm from the diesel exhaust of a lorry.

From the day mode: The omit routine, works the same for both
mode 1 or mode 2 operation.
0712 03:46P
System Off
Only the main or master code can be used to
Enter the Main or Master User code (1234). omit areas or zones.

Hello XXXXXX
Press the NO key to prevent the system from
Set System?
setting.

Press the NO key.


On Version 7000 software, this display
appears to allow you to return to the day mode
YES: to Continue
if you have made a mistake, press YES/PART
No: to Quit
key to continue.

Press the YES/PART key.

Press the YES/PART key to select the omit


Omit Zone?
routine.

The description Area 1, Area 2 and Area 3


Press the YES/PART key. may have been changed by the installation
engineer to be more realistic, i.e. Offices
Stores Workshops etc.
On
Area 1
Press the NO key to toggle the area ON or
OFF as required, then press the YES/PART
Press the YES/PART to accept or NO key to key to accept.
toggle as required.
Repeat for the other areas.
On
Area 2 After the areas have been selected, you are
then able to select the zones that can be
Press the YES/ PART key to accept or NO omitted in the same manner.
key to toggle as required.

Repeat for Area 3. Zone selection menu is only available on


version 7000 software, enter zone required.
Enter Zone No. --
Once in zone options, on the Abacus 72 or
Abacus 8/80, by typing in the REM number you
can select the first zone on that REM, i.e. type
Enter Zone number required. in 4 to select zone 41.

There is no requirement to go through all the


On 03A zones, once you have omitted the zone/s you
Hallway require press O/ESC key.

Repeat for Zones as required.

Chapter 2. 8

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Press O/ESC key when satisfied. On pressing O/ESC key, when display reads
Set System the panel returns to the day mode
with the appropriate zone/s omitted i.e. Fire,
Hello XXXXXX
PA, and or 24 hour.
Set System?
On pressing the YES/PART key, the system
Press the YES/PART key to set the system or will set with zone/s selected omitted. – See
O/ESC to return to day mode with Zone/s Mode 1/2 setting the system. (Page 2.1/2.4).
omitted.

Reactivating Omitted Zones

All zones will be reactivated when the panel is next set or on entry to the Omit Zone/Area procedure.

From the day mode:

Enter the Main or Master User code (1234).


0712 03:46P X!
System Off
Note. X! indicates, zone/s omitted.

Hello XXXXXX Press the YES/ PART key.


Set System?

Setting 123 ok! Enter the user code to abort setting and return to the day mode. Zones are
Please leave… now rearmed.

Alternative Method of Reactivating Omitted Zones

From the day mode:

0712 03:46P X! Enter the Main or Master User code (1234).


System Off

Hello XXXXXX Press the NO key.


Set System?

Omit Zone? Press the YES/PART key.

On Press the YES/PART key for all areas.


Area 1

On 02A When Zone selection menu or a Zone is displayed, press the 0/ESC key
Foyer twice to return to the day mode.

Chapter 2. 9

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Attention Display

In the day mode, an attention indication is given to inform you that


0712 03:46P X! something has occurred, that although it has not caused an alarm, needs
System Off attending to or recording.

When setting the installation and returning to the Day mode the display will show X! or T!, this is to
call your attention to the fact that during the last set period something needs your attention.

X! is displayed for one of the following reasons:

1. The system was only part set. (Before Version 5000 software).
2. A zone was omitted during the last set period.
3 A 24-hour zone is currently omitted.
4. A zone was on test during the last set period.

T! is displayed for one of the following reasons:

1. A test zone activated during the last set period. *


2. Telephone line fault reported during last set period. *
3. Battery fault indicated during last set period. *
4. Mains fault indicated during last set period.
5. Zone trouble indicated during last set period. Etc.
* Call your alarm company for advice.

Use the event log to examine the cause of the indication.

Quick Set/Help Keys

The two ! keys, on the remote keypad may have been programmed as quick set, either Chime, Part Set
or Full Set. (Alternatively, they may have been programmed as Help Keys – PA, FIRE or MEDICAL).
Also on Abacus panels with built in keypads if quick set is turned on then Keys 1 and 3 pressed together
toggles Chime on and off, keys 4 and 6 pressed together starts the part set routine and keys 7 and 9
pressed together starts the full set routine.

To use the quick set keys to set or part/set, press the appropriate pair of keys and follow the setting
/part setting displays as for using codes (to abort setting enter a user code).

To use quick set keys, to turn the chime on and off – Press the two ! keys (on the remote keypad) or 1
and 3 to keys (on a panel keypad) together and check display reads Chime On (Chime Off) press the
keys again to toggle display Chime Off (Chime On). Repeat as required.

If ! Keys on the remote keypad have been programmed as Help keys (PA, FIRE or MEDICAL), on
pressing both keys together the appropriate alarm will be given, and if a communicator is fitted, will
signal to the central station.

Keyswitch Operation

Ensure that the keyswitch is in the same state as the panel (i.e. Unset).

Switch the keyswitch to state required (i.e. Set) panel now starts the exit routine, leave by the normal
exit route and complete the setting in the normal way (See setting the system).

On entry, proceed to keyswitch through the normal entry route. Ensure that the keyswitch is in the
same state as the panel (i.e. Set) and turn switch to Unset position.

In the event of a fault condition, investigate at Keypad (see chapter 4).

Chapter 2. 10

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Abort the Setting Routine

To abort the setting routine, whilst the exit sounder is still operating enter the user code or return the
keyswitch to the Unset position.

Reset the System

The Association of Chief Police Officer (ACPO) intruder alarm policy on alarm systems with
communicators fitted states …..that following an activation, resetting of the alarm shall be undertaken
by means not normally available to the customer (i.e. engineer reset or by central station).

After the installation as generated an alarm condition, the installation, if not in the unset condition,
must be unset (all areas) and the cause of the alarm investigated, either by entering the log (see chapter
4) or pressing the YES/PART key as below. The master or main code may be required to unset the
other areas and enter the log.

User Reset

Enter the user code to silence the Alarm.

When display is as shown press the YES/PART key and display changes to
0712 03:46P
the cause of an alarm for 2 seconds (5 seconds version 7000). (Press the
ALARM
YES/PART key twice for fast entry to log –version 5000 or later).
07/12 03:46P 08A
Note the cause of alarm and rectify (i.e. reset the PA push switch).
08 PA Office

Enter the user code again, display reads.

Hello XXXXX Press the YES/PART key, as the system starts to set abort the setting by
Set System ? entering the user code.

Note. Fire, PA and warning signals, are all reset as above, Intruder Alarms, with remote signalling,
(See ACPO policy) will require to be reset by either: Engineer reset, Coded reset or Remote
reset. Your installation engineer will advise you on your method.

Engineer Reset

If you are unable to reset your installation, your display will advise you to call the Engineer, when you
attempt to reset the panel.

Providing that the engineer as programmed his/her telephone number, use


Phone Engineer
this number to inform the engineer that you require a reset, giving as much
0181 893 5642
information as possible on the cause of the Alarm.

Note. It may take several hours for an engineer to respond to your call for a reset, especially at peak
times and during storms or power cuts. Call your alarm company as soon as possible.

Remote Reset

If you are unable to reset your installation, your display will advise you to call the Engineer, when you
attempt to reset the panel.

Providing that the engineer as programmed the central station telephone


Phone Engineer number, use this number to inform the central station that you require a
0181 893 5642 reset, giving as much information as possible on the cause of the Alarm.
(On Version 7000 software the engineer can program display to read
‘Phone ARC’ (Alarm Receiving Centre).

Chapter 2. 11

www.PDF-Zoo.com
Detection Systems Abacus User Guide

The central station Officer will unlock your installation, over the communication link, providing that
they are satisfied that it is a genuine operator error, further investigation by an alarm engineer is not
required and you are not in a position that police response may be withdrawn.

Carry out the user reset as above.

Code Reset

If you are unable to reset your installation, your display will advise you to call the Engineer and quote a
number, when you attempt to reset the panel.

Providing that the engineer as programmed the central station’s telephone


Phone Engineer number, use this number to inform the central station Officer, that you
0181 893 5642 require a Detection System’s Coded reset, quote the number displayed
(example shown below 4542) giving as much information as possible on the
cause of the Alarm. (On Version 7000 software the engineer can program display to read ‘Phone
ARC’ (Alarm Receiving Centre).

The central station Officer, may provide you with an anti code, (for example
1, 2, NO, 4) providing that they are satisfied, that it is a genuine operator
Quote # 4542 error. Also that further investigation by an alarm engineer is not required,
and you are not in a position that police response may be withdrawn.

Enter the anti code (1, 2, NO, 4) to unlock the installation, then carry out the user reset routine as
above.

Chapter 2. 12

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Setting Options Flow Chart

Italic is used to indicate, only available on installation set to Mode 2 area operation.

Some functions may not be available to your code. (See codes chapter 1)

Unset (Day Mode)

Enter User Code

1=Prog 2=Test
Set System ? NO* Omit Zone ? NO 3=Log 4=Day

YES YES See Chapter 3 or 4


Omit zones as required

Notes.
Setting ok! NO Set Area 1? The flow chart will vary dependant
on the number of areas in your
YES YES/NO installation, and the area setting
states etc.
P/Setting ok! Set Area 2?
*Version 7000 software, introduced
YES YES/NO a new menu, in case of mistake to
allow return to day mode, at the
S/Setting ok! Set Area 3? new menu press the YES/PART
key to continue or NO to return to
YES/NO day mode.

System Set (as appropriate)

Unsetting Options Flowchart

Enter protected installation and proceed via entry route to the keypad. Entry warning tones may be
sounding.

System Set (as appropriate)

Enter User code

Unset All Areas ? NO Unset Area 1? Note.


The flow chart will vary dependent
YES YES/NO on the number of areas in your
installation, and the area setting
states etc.
Unset Area 2?

YES/NO

Unset Area 3?

YES/NO

System Set/Unset (as appropriate)

Chapter 2. 13

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Chapter 3 – Programming
General

The installation engineer carries out most of the programming of your Abacus installation. It would be
nice to leave it all to the engineer, but for day to day operation, and for system security, a small amount
of programming has to be left to the user.

User programming is carried out by the master, or main (not code programming) user codes only.

Programming of the Abacus system is user friendly, once you have entered either the main or master
code, the display gives you options, if the display is not what you require press the NO key, if display
is as required either press the YES/PART key or the number indicated. A pointer ( > ) may appear
from time to time, on pressing the NO key, to indicate a value to be changed, either key in value
required or press the NO key to scroll options available.

To program characters (i.e. User names) for identification, each number key will give three letters and
their respective number, (0/ESC key is used for a range of symbols, shown in chart as 0) as shown on
the remote keypad when flap is removed, or see keystroke character chart below. For version 7000
software, a library has been introduced to speed up engineer programming, because of this numbers
have been moved to the O/ESC key. (See second Chart below). Abacus 8/15P uses old chart no library.

Key Stroke Character Chart

a=1 b=11 c=111 A=1111 B=11111 C=111111 1=1111111


d=2 e=22 f=222 D=2222 E=22222 F=222222 2=2222222
g=3 h=33 i=333 G=3333 H=33333 I=333333 3=3333333
j=4 k=44 l=444 J=4444 K=44444 L=444444 4=4444444
m=5 n=55 o=555 M=5555 N=55555 O=555555 5=5555555
p=6 q=66 r=666 P=6666 Q=66666 R=666666 6=6666666
s=7 t=77 u=777 S=7777 T=77777 U=777777 7=7777777
v=8 w=88 x=888 V=8888 W=88888 X=888888 8=8888888
y=9 z=99 Space=999 Y=9999 Z=99999 9=9999999
Blank=0 !=00 “=000 #=0000 $=00000 %=000000 &=0000000
‘=0000000 (=0000000 )=0000000 *=0000000 +=0000000 ,=0000000 . =0000000
0 00 000 0000 00000 000000 0000000
/=000000000000000 0=000000000000000

See system features, also some of the characters may not be available on early version of software, in
this case, the keys may require less pushes than stated in the keystroke character chart.

Key Stroke Character Chart (Software Version 7000)

a=1 b=11 c=111 A=1111 B=11111 C=111111


d=2 e=22 f=222 D=2222 E=22222 F=222222
g=3 h=33 i=333 G=3333 H=33333 I=333333
j=4 k=44 l=444 J=4444 K=44444 L=444444
m=5 n=55 o=555 M=5555 N=55555 O=555555
p=6 q=66 r=666 P=6666 Q=66666 R=666666
s=7 t=77 u=777 S=7777 T=77777 U=777777
v=8 w=88 x=888 V=8888 W=88888 X=888888
y=9 z=99 Space=999 Y=9999 Z=99999
Blank=0 0=00 1=000 2=0000 3=00000 4=000000
Repeat presses of the 0/ESC key will give the following: 5, 6, 7, 8, 9, !, ”, #, $, %, &,
‘, (, ), *, +, ,, -, ., /, :, ;, <, =, >, ? and @.

Chapter 3.1

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Programming tips for Version 7000 Software.

1. To delete the last letter, press 0/ESC key or YES/PART key followed by the NO key.
2. To delete the displayed text, press YES/PART key,0/ESC key followed by the NO key.
3. For fast exit, press YES/PART key followed by 0/ESC key then YES/PART key again.
4. When in library press the 0/ESC key to delete the current word displayed.
5. Press the YES/PART key to accept the letter or word
6. Press the YES/PART key twice for a space.

Code Programming

ONLY A MASTER CODE CAN PROGRAM USER CODES.

An Abacus panel, when it leaves the factory has only one user code set, code 1 is always a master code,
factory set to 1234, this code cannot be removed, it can be changed to any number 4 (4, 5 or 6) digits
you require (See System Features chapter 1). Should you attempt to delete code 1, it will revert to the
factory default of 1234.

From the day mode, enter the User master code (1234).
0712 03:46P
System Off

At this display, press the NO key. (XXXXXX = Code holders name if


Hello XXXXXX programmed).
Set System?

Press the NO key.

On Version 7000 software, this display appears to allow you to return to the
YES: to Continue
day mode if you have made a mistake.
No: to Quit
Press the YES/PART key.

Omit Zones ? At this display, press the NO key.

At this display, press the 1 key to enter the programming mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

1=Code 2=Chime At this display, press the 1 key to enter the code-programming mode.
3=Time 4=Engnr
On Version 7000 software enter the code number you wish to change (see
Enter Code No. - - system feature chapter 1)

At this display, press the YES/PART key to go to code 2 or press the NO


Code 1 =Used key to edit (code 1), the = sign changes to >. If the number is not to be
Master changed press the YES/PART key, to change number press the NO key
and enter the new 4, 5 or 6 digit code required. (See System Features also
Abacus 6 old software code 7 Duress).

Code 1 >654321 Press the YES/PART key, the > will move to either:
Master
For code 2 and above towards code type (Master).

For code 1 it bypasses this option and points to code name (code 1
is always a master code).

Chapter 3.2

www.PDF-Zoo.com
Detection Systems Abacus User Guide

For code 2 and above press the NO key until display reads the code type required. (Master, Main,
Clnr, Area 1,Area 2, Area 3, Duress, Holder and On/Off [Clnr = cleaner]). When the code type
required is displayed press the YES/PART key to accept and the > points away. (See System Features)

Press the YES/PART key to accept a user’s name and repeat for next code.
Code 1 654321 To program in a user’s identification name press the NO key, refer to the
Master >Bill keystroke/character chart and press the keys required. I.e. for Bill, press the
1 key five times, YES/PART key, the 3 key three times, YES/PART key
the 4 key three times the YES/PART key then the 4 key three times. (To correct a error press the
YES/PART key followed by the NO key) To complete press the YES/PART key until next code is
displayed. To make a space press the YES/PART key twice. (Version 5000 or later software, Quick
escape, Press the 0/ESC key followed by YES/PART key, or quick delete of full name, press 0/ESC key
followed by NO).

On completion of programming of the codes, press the 0/ESC key.


Code 2 =Spare
Master For mode 2 area operation, version 5000 software or later, the following
programming is available.

This menu selects the area that the main code and duress codes will set and
Main =123 unset. To select press the NO key until main = area numbers required, then
Duress =123 press the YES/PART key to accept. Repeat for Duress (Software version
5000 only) on pressing the YES/PART key the display changes to:

Press the 4 key to return to the day mode and check that the new number(s)
1=Prog 2=Test works and any old number(s) is/are deleted, or press the number displayed,
3=log 4=Day(Quit) for function required.

Notes. Codes can only be programmed/deleted by the master code.

One master code (code 1) is the minimum number of user codes for the system. Code 1 is
factory default as 1234; it should be changed from this number to one that only you know, as
soon as possible for the security of the installation. It is advised not to use consecutive or
numbers like 1066 that can be easily compromised.

When area’s are used, a minimum of one master code and one code for each area used must be
programmed for correct operation of the installation.

When programming codes it is recommended that names, or idents, are prgrammed for each
code, for identification of which code user operated the system.

New numbers only become active on return to the day mode.

If a number has already been programmed as a code and you attempt to program the same
number again, code conflict will be detected (erro tone sounded and code displayed removed)
and prevent that number being used, retype in a different number or press the YES/PART key
to carry on programming.

Delete a User Code

ONLY A MASTER CODE CAN DELETE A USER CODES.

Should you attempt to delete code 1, it will revert to the factory default of 1234.

From the day mode, enter the User Master code (1234).
0712 03:46P
System Off

Chapter 3.3

www.PDF-Zoo.com
Detection Systems Abacus User Guide

At this display, press the NO key. (XXXXXX = Code holders name if


Hello XXXXXX programmed).
Set System?

On Version 7000 software, this display appears to allow you to return to the
YES: to Continue
day mode if you have made a mistake, press YES/PART key to continue.
No: to Quit

At this display, press the NO key.


Omit Zones ?

At this display, press the 1 key to enter the programming mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

At this display, press the 1 key to enter the code-programming mode.


1=Code 2=Chime
3=Time 4=Engnr

On Version 7000 software enter the code number you wish to change (see
Enter Code No. - -
system feature chapter 1)

At this display, press the YES/PART key to go the next code, repeat until
Code 1 =Used code to be deleted is displayed, press the NO key to edit, the = sign changes
Master Bill to >. press the NO key again and check the word ‘Used’ disappears.

Press the YES/PART key (do not put any number in) Display will step to
Code 3 > next code. Repeat to delete further codes as required. (Abacus 8/80 to index
Main Anne in 10s i.e. key in 3 to jump to code 30). On completion press 0/ESC once.
(Twice for mode 2 operation, Version 5000 software).

Press the 4 key to return to the day mode and check that the code has been
1=Prog 2=Test deleted, or press the number displayed, for function required.
3=Log 4=Day(Quit)

Program Chime

From the day mode, enter the Main or Master code.


0712 03:46P
System Off

Hello XXXXXX At this display, press the NO key. . (XXXXXX = Code holders name if
Set System? programmed).

On Version 7000 software, this display appears to allow you to return to the
YES: to Continue
day mode if you have made a mistake, press YES/PART key to continue.
No: to Quit

Omit Zones ? At this display, press the NO key.

1=Prog 2=Test At this display, press the 1 key to enter the programming mode.
3=Log 4=Day(Quit)

Chapter 3.4

www.PDF-Zoo.com
Detection Systems Abacus User Guide

At this display, press the 2 key to enter the Chime-programming mode.


1=Code 2=Chime
3=Time 4=Engnr

Press the NO key to toggle chime on or off, press the YES/PART key to
Chime = Off accept.

On Version 7000 software enter the Zone number you wish to change (see
Enter Zone No. - - system feature chapter 1)

Press the NO key to toggle chime on or off for zone displayed, or press the
ON 01A YES/PART key to accept and move on to the next zone. (On Abacus 72 or
Front Door Abacus 8/80 press the REM number key to jump to the first zone on that
REM). Repeat for further zones then press the 0/ESC key when complete.

At this display, press the 4 key to return to the day mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

Programming the Date and Time

From the day mode, enter either a Master or Main code.


0712 03:46P
System Off

At this display, press the NO key. . (XXXXXX = Code holders name if


Hello XXXXXX programmed).
Set System?

YES: to Continue On Version 7000 software, this display appears to allow you to return to the
No: to Quit day mode if you have made a mistake, press YES/PART key to continue.

At this display, press the NO key.


Omit Zones ?

At this display, press the 1 key to enter the programming mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

At this display, press the 3 key to enter the time-programming mode.


1=Code 2=Chime
3=Time 4=Engnr

At this display, key in the date and time in the following format:
0712 03:46P 07 YES/PART 12 YES/PART 08 YES/PART 45 YES/PART (to indicate
Τ the 7th day of December at a time of 8 hour 45 minutes) as the YES/PART
key is pressed the Τ will be seen to move across the screen. On the earlier
version of software the clock was a 24 hour clock, the A (AM) or P (PM) did not appear on the display.
When the Τ indicates, to toggle between A or P press the NO key, when display is as required press the
YES/PART key.

At this menu, press the 4 key to return to the day mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

Chapter 3.5

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Notes. Should a incorrect value be inserted the panel will appear to lock up, enter the correct value
and the panel will start functioning again (i.e. if 15 is keyed in for the month, then key in say
01 YES/PART for January).

The clock is stopped during time programming and restarts on completion (i.e. restart as soon
as display shows 1 = Prog etc. menus above).

Lock and Unlock Engineer Programming or Engineer Access via Modem

From the day mode, the engineer can with his/her code operate the system and change all the
programming functions on your installation, providing that you have left the user programming as
engineer Unlocked. If you program as engineer Locked, the engineer is limited to operating and testing
only, and requires the user’s master or main code to change any engineer programming functions. This
enables you to be aware of any changes to your installation performance.

If your installation as been set for Association of British Insurer (ABI) mode for modem
communication (Upload/Download) the installation engineer requires you to place the installation at
the Engineer mode as shown below.

From the day mode, enter either a Master or Main code. (Main code cannot
0712 03:46P lock/ unlock the engineer access).
System Off

At this display, press the NO key. . (XXXXXX = Code holders name if


Hello XXXXXX programmed).
Set System?

YES: to Continue On Version 7000 software, this display appears to allow you to return to the
No: to Quit day mode if you have made a mistake, press YES/PART key to continue.

At this display, press the NO key.


Omit Zones ?

At this display, press the 1 key to enter the programming mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

At this display, press the 4 key to enter the Engineer-programming mode.


1=Code 2=Chime
3=Time 4=Engnr

Leave at this menu for engineer access via modem. (Strobe will flash to
Engineer Code
warn you that the panel is left at access for modem version 5000 software).
To program the Lock/Unlock function, press the NO key.

At this display, press the NO key to toggle between LOCKED and


Engineer Access UNLOCKED, then press the YES/PART key to accept. (This function is
is UNLOCKED ok? only available to the Master code).

At this display, press the 0/ESC key, then the 4 key to return to the day
1=Code 2=Chime
mode.
3=Time 4=Engnr

Chapter 3.6

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Programming Flow Chart

Unset (Day Mode)

Enter User Code

Set System ? Omit Zones ? 1=Prog 2=Test


NO* NO 3=Log 4=Day(Quit)

(See Chapter 2) (See Chapter 2) 1 2 3


(See Chapter 4)

1=Code 2=Chime
3=Time 4=Engnr
1 2 3 4

See Page 3.6- To


See Page 3.5-To Lock/Unlock
Change Date and Engineer Program.
See Page 3.4- To
Program Chime. Time.
See Page 3.2-Code
Programming YES/PART
Page 3.3-To Delete
a Code. 1=Code 2=Chime
3=Time 4=Engnr
YES/PART
or 0/ESC 0/ESC YES/PART 0/ESC

1=Prog 2=Test
3=Log 4=Day(Quit)

At this menu press 4 key to return to the


day mode, or press the key indicated to
carry out further function.

Note. * Version 7000 software, introduced a new menu, in case of mistake to allow return to day
mode, at the new menu press the YES/PART key to continue or NO to return to day mode.

Chapter 3.7

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Chapter 4 – System Testing and Fault Indication


General

The Abacus panels contain no user serviceable parts. Removing of the covers will bring up a tamper or
alarm condition and will expose you to the risk of contact with lethal voltages.

System testing should be carried out regularly, to quickly identify any problems that may have
developed, so that they can be rectified.

Most user checks should be completed as habit as you set and unset your system.

Each day as you unset the system, read the display and investigate any messages displayed.

Internal Sounder Checks

Each day, as you set and unset your Abacus alarm panel, check that your exit/entry tones can be heard.
Also, regularly, check that the chime tone is generated from the exit terminator push, and any zone
programmed as chime.

Zone Tests

Caution. On systems with remote communicators, PA and Fire zones should NOT be tested by
the user as they are always active and will ring the Bells etc. and signal to central
station. On other installations will ring the bells etc. Testing of the PA and Fire zones
should not be tested by the user and therefore left to the alarm engineer.

On a regular basis, it is recommended to activate each detector in turn, to ensure that the detector is
working correctly as follows:

From the day mode, enter the Main or Master code.


0712 03:46P
System Off

At this display, press the NO key. (XXXXXX = Code holders name if


Hello XXXXXX programmed).
Set System?

On Version 7000 software, this display appears to allow you to return to the
YES: to Continue day mode if you have made a mistake, press YES/PART key to continue.
No: to Quit

At this display, press the NO key.


Omit Zones ?

At this display, press the 2 key to enter the test mode.


1=Prog 2=Test
3=Log 4=Day(Quit)

At this display, press the 1 key to test zones.


1=Zone 2=Bell
4=Active

This display will change and indicate the zone as


Test ok! they are activated. At the same time, the sounder Test 02A
is turned On (i.e. zone 2A a Hallway PIR). If an Hallway PIR
Exit Terminate button is fitted, and pushed, it will
be displayed as Exit Terminate.

Chapter 4.1

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Do not activate PA, Fire, or 24 hour Detectors, leave testing of these types of detectors to the
alarm engineer.

If required press the YES/PART to toggle the SW12 V to unlatch detectors if required.

Test all detectors in turn and check that they respond correctly. Press the 0/ESC key to return to:

At this display press 0/ESC key and then the 4 key to return to the Day
1=Zone 2=Bell
mode, or carry out further tests as follows.
4=Active

Zone Active Test

To reset the zone active test, first enter then escape from the zone test above. On early versions of
software, the zone active test was also reset each time the system was set. This reset was discontinued
to enable the user to check for zone activation over a period of time.

From this menu, press the 2 key for test.


1=Prog 2=Test
3=Log 4=Day(Quit)

At this display, press the 4 key for active test.


1=Zone 2=Bell
4=Active

At this display, once a zone has been activated the corresponding number is
A <INACTIVE> B deleted from the display. On the larger Abacus systems, the display is
123456 123456 changed to indicate the group of zones, in which case press the YES/PART
key, to step on to the next group of zones as required.

Caution. Do not activate PA, Fire, or 24 hour Detectors, leave testing of these types of detectors
to the alarm engineer.

Walk round your installation and activate all detector zones in turn, then ensure that the appropriate
number has been removed from the display. When completed press the 0/ESC key.

1=Zone 2=Bell At this display, press the 1 key, followed by the 0/ESC to reset the active
4=Active display and return to this display.

At this display press 0/ESC key and then the 4 key to return to the Day mode, or carry out further tests
as follows.

Bell Test and Sounder Tests

At this display, press the 2 key for bell/sounder test.


1=Zone 2=Bell
4=Active

At this display, press the 1 key to test the Bell (Siren) and Strobe.
1=Bell 2=A1 LS
3=A2 LS4=A3 LS

At this display, the Bell (Siren) will sound and the Strobe will flash. Press
Test the 0/ESC key the bell (Siren) will stop but the strobe will continue to flash
until the panel is returned to the day mode.

At this display, press the 2, 3, or 4 key as required for the area sounder to be
1=Bell 2=A1 LS
tested. (Area sounders A2 and A3 are only available on the Abacus 8/80,
3=A2 LS4=A3 LS
15R and 72 panels).

Chapter 4.2

www.PDF-Zoo.com
Detection Systems Abacus User Guide

At this display, press the 1, 2, 3 and 4 key in turn to check different sounder
1=Part 2=Exit tones are working correctly at all sounders. When completed, press the
3=Entry 4=Alarm 0/ESC key three times, followed by the 4 key, to return to the day mode.

Alarm Fault Display

Date Time Zone state or condition

0712 03:46P TRBL If the descriptor message has been programmed, when reading the log
04 Nite press the 1 key for the additional information to be displayed for 2 second.

Zone No. Zone type or descriptor

See log information explained on next page.

Reading the Log

From the day mode, enter the Main or Master code.


0712 03:46P (Version 5000 or later software, fast entry to log is available, if in day mode,
System Off display reads Alarm, by pressing the YES/PART key twice).

At this display, press the NO key. (XXXXXX = Code holders name if


Hello XXXXXX programmed).
Set System?

YES: to Continue On Version 7000 software, this display appears to allow you to return to the
No: to Quit day mode if you have made a mistake, press YES/PART key to continue.

At this display, press the NO key.


Omit Zones ?
(If panel is in an alarm condition, this menu is not displayed).

At this display, press the 3 key to enter the Log. (Abacus 6/14 + COM panel
1=Prog 2=Test
do not have a printer, and will miss the next menu by going into View).
3=Log 4=Day(Quit)

At this display, press the 1 key to view the log.


1=View 3 key to print out a list of the log events (see System Features).
3=List 4=Program 4 Key to print out the programming. (See System Features).

When in 1 = View, press the YES/PART to scroll to previous events (back in time one event), and NO
key to scroll to the more recent events (forward in time one event).

Version 5000 software or later, the following search facilities are available by pressing the key
indicated:

1 Show additional data if available (i.e. additional zone data).


2 Search backwards, for last Tamper event.
3 Search backwards, for last Alarm event.
4 Search backwards, for last Trouble event. (Abacus 8/80, 15R and 72 only).
5 Search backward, for last Omit event. (On older software, this facility was available
by pressing 2 at the above display.
6 Search backwards, to the last Miscellaneous event (i.e. watchdog).
7 Move forward 10 events in the log.
8 Search backwards, for the last Bad Set event.
9 Move backwards, 10 events in the log.
0/ESC Abort the log mode.

Chapter 4.3

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Press the 3 key (3 = List), on panels with print out facility will print out the log. Version 5000 or later
software, on pressing the 3 key, before print out commences you are given a date range choice:

At this menu, by pressing the YES/PART key the complete log can be
Print Out y/n ? printed out. By typing in the dates required, the print out will be over the
15/02 … 00/00 period typed in. I.e. by keying in NO 15 YES/PART 02 YES/PART 12
YES/PART 02 YES/PART, the print out will be of all events between 12th
of February and 15th February.

Press the 0/ESC key to abort the printout.

Press the 4 key (4 = Program), on panels with print out facility will print out the User programming
states. (The engineer can print out the complete panel programming).

Press the 0/ESC key to abort the printout.

At this display, press the O/ESC key then the 4 key to return to the Day
1=View mode.
3=List 4=Program

Log Information Explained

Information stored in the log, can either be read from a print out or on the keypad display. If read from
keypad display, additional information may be obtained by pressing the 1 key.

At version 5000 software addition recorded events was added to the log, also each item, where
appropriate, has been increased to three lines. For this reason, it is not possible to indicate in the log
information for the changes in software. If the indication you get is slightly different to as below it
could be because of software variant or panel programming. I.e. Area 1 is displayed as House –
programming of the Area 1 has been changed to House.

When reading the log also read the events in close proximity to each other. I.e. The final exit door was
opened and 20 seconds later the system was unset by Gary, this is the normal recording seen in the log
for the unsetting of the system, two events recorded in the log.

1502 142540 Off The system was turned Off, by Gary, using keypad number 5, on 15th
K5 Gary February, at 2:25 PM and 40 seconds.

1502 142520 01A (Noted from event above) Gary entered the installation by the House front
House Front Door door (Zone 1A) and took 20 seconds to unset (turn Off) the system
01 Fx

1502 142015 Off


K4 Ameet

1502 142015 X! (Noted from event above) Ameet although either a main or master code
Area 1 user only unset area 1. Using keypad 4 at 2:20 PM and 15 seconds on the
15th of February.

1502 103035 On Gary set the installation at 10:30 AM and 35 seconds on 15th of February
K7 Gary using keypad 7 (Built in Keypad or remote keypad 7).

1502 083020 With reference below, Gary rearmed all zones that have been omitted
Zone Rearms which include zones previously part set but in this case zone 4A the rear
fire door at 8:30 AM and 20 seconds on the 15 of February using keypad 1.
1502 083020 Off
K1 Gary

Chapter 4.4

www.PDF-Zoo.com
Detection Systems Abacus User Guide

1502 081010 X04A With reference below, a main code user (no identification programmed)
Rear Fire Door omitted the rear Fire Door, a 24hr contact on zone 4A, at 8:10 and 10
04 24Hr seconds on the 15 of February using keypad 1.

1502 081010 Off


K1 Main

To save repetition, in the following explanations of the log events, reference to date and time, other log
readings and the keypads used, although recorded have been left out.

1502 081010 Off System was unset by a keyswitch fitted to the system (your system would
Ksw Master require a keyswitch to be fitted). Displays Master for all area or the
appropriate Area operated.

1502 081010 On Area 1 was set using the keyswitch fitted to the system.
Ksw Area 1

1502 081010 X! Either Area 2 was omitted, when the system was set, by a main or master
Area 2 code or was unset by that code. Area 2 was unprotected. (Printout/Display
will give a similar indication for Area 1 or Area 3, Area word may be
reprogrammed for location name).

1502 081010 X03A When the panel was set, zone 3A, the lounge detector was omitted or on
Lounge test.
03 Nite

1502 081010 When the panel was set, all zones programmed as part were omitted (i.e.
Part - Set all of the bedrooms).

1502 081010 BAD On attempting to set the panel, zone 3, the kitchen PIR was in an alarm
Kitchen PIR condition and caused the system to fail to set. The installation was not
03 Nite protected.

1502 081010 TRBL The kitchen detector as signalled a trouble state (see detector specification
Kitchen PIR for reason) for panels with this facility see Chapter 1 System Features,
03 Nite

1502 081010 TRBL The panel has detected that the battery back up power supply is low or
Power disconnected (i.e. battery requires replacement or if after a mains failure
recharging).

1502 081010 The battery has now recharged to a level to be able to start supporting the
Reset Power system again, or been replaced.

1502 081010 TRBL The mains supply to the panel has been interrupted or disconnected.
Supply

1502 081010 The mains supply has been restored to the panel.
Mains ok

1502 081010 TRBL A non-plug on DS communicator or Red care communicator as detected a


Phone line fault.

1502 081010 TRBL A plug on DS communicator has stopped communicating with the Abacus
Comms panel.

Chapter 4.5

www.PDF-Zoo.com
Detection Systems Abacus User Guide

1502 081010 TRBL A plug on DS communicator has detected that a telephone as been
Off Hook connected to the BT line and the receiver has been lifted off its cradle.
(Normally used on incoming calls bard lines).

1502 081010 TRBL A plug on DS communicator has detected a ring in tone on the BT line.
Ring In (Normally used on incoming calls bared lines).

1502 081010 TRBL A plug on DS communicator has signalled to central station and has failed
FTC to obtain an acknowledge signal from the receiver. The receiver may have
been engaged.

1502 081010 TRBL A plug on DS communicator has detected that the BT line has been
Line Cut disconnected or shorted out.

1502 081010 TRBL A plug on DS communicator has detected no tones on the BT line.
No Tones

1502 081010 A plug on DS communicator has successfully communicated with the


Ack CS central station receiver and received the acknowledge tone back.

1502 120004 The system detected an irregularity during a self-test function and found it
Watch Dog necessary to carry out a reset. It also carries out a reset at power up.

1502 081010 TAMP A tamper was detected on the front door connected to zone 1 (i.e. the wires
Front Door to the front door detector has been cut).
01 FX

1502 081010 TAMP A tamper has been detected on the Bell circuit or the Bell disconnected.
Bell

1502 081010 TAMP The panel has detected that the control panel has been opened.
System

1502 081010 TAMP The panel has detected that the positive auxiliary tamper loop has been
Aux + broken. This is used normally to tamper any auxiliary units i.e. internal
loud speakers. (Abacus 8/80, Abacus 15R and Abacus 72 panels only).

1502 081010 TAMP The panel has detected that the negative auxiliary tamper loop has been
Aux - broken. This is used normally to tamper any auxiliary units i.e. remote
power supply units. (Abacus 8/80, Abacus 15R and Abacus 72 panels
only).

1502 081010 TAMP The panel has detected a tamper on the wiring to the REM unit or the REM
REM unit cover was removed. (On the larger abacus systems, a REM number
will be displayed to indicate which REM).

1502 081010 TAMP Modem (remote access via the telephone line) was attempted without
Modem proper authority.

1502 081010 Modem (remote access via telephone line) was performed.
Modem

1502 081010 On The Engineer set the installation.


K3 Engnr.

Chapter 4.6

www.PDF-Zoo.com
Detection Systems Abacus User Guide

1502 081010 Off The Engineer unset the installation. (The engineer is only able to unset the
K3 Engnr. installation if it was first set by the engineer. The engineer cannot unset
any part of an installation if it was set by a user code).

1502 081010 The installation was put into an engineer mode.


Engineer

1502 081010 The engineer entered the engineer’s programming mode – he/she may have
Prog Chng changed one or more of your system parameters, or just checked that they
are correct.

1502 081000 The date or time was changed to the date of the 15th of February and/or a
Time Chng time of 8:10 AM.

1502 081010 06B A smoke detector on the landing connected to zone 6 cct B has been
Landing Smoke activated and signalled fire.
06 FIRE

1502 081010 The panel was reset after generating a Fire Alarm.
Reset FIRE

1502 081010 05A A bedroom PA button has been activated connected to zone 5A and
Bedroom Button signalled PA.
05 PA

1502 081010 The panel was reset after generating a Personnel Attack Alarm.
Reset PA

1502 081010 02A The hallway PIR, on zone 2A, was activated when the panel was set and
Hallway PIR caused an intruder alarm to be generated.
02 ExFx

1502 081010 The alarm activated (see adjacent log reading for cause) triggered the
ALARM ok! communicator and the BT lines were in working order. I.e. no line faults.

1502 081010 The alarm activated and the communicator was unable to signal to the
ALARM TRBL central station, or no communicator fitted.

1502 081010 The panel was reset after generating an Intruder Alarm.
Reset Alarm

1502 081010 A Duress code was entered and remote signalling took place if a
Duress communicator was fitted.

1502 081010 Off The system was unset (On = Set) using a duress code and remote
Duress signalling took place if a communicator was fitted.

1502 081010 User The two ! keys on keypad 3 were pressed together and a medical alarm
Keypad 3 MED was signalled to the central station if a communicator was fitted.

Chapter 4.7

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Quick Entry to the Log

On version 5000 software or later, when the display reads ALARM, press
0712 03:46P the YES/PART key (Once to display cause of alarm for 2 seconds [software
ALARM! 7000 5 seconds]) Twice for fast entry to the Log.

The display now reads the last event in the log press the YES/PART key to
0712 11 55 Off step back through the log in the same way as reading log above.
K7 Gary

Service Required

The alarm system may inform you that a service is required when you unset the system. Inform your
installation or service engineer as soon as possible.

From the day mode, on setting the system you are also reminded that a
service is required. If you ignore this request for 14 days, (Version 5000
0712 03:46P
software or later 28 days) the panel will lock out and you will not be able to
Service Required
set the system. Your premises will not be protected. The display will, on
attempting to set the system display the following and then return to day
mode.

The service engineer can give you an anti code, on quoting the number
Phone Engineer given, to unlock your system for 14 days. To unlock the system, from the
0181 893 5642 day mode key in the anti- code given (i.e. key in 7, 9, NO, 5), should the
engineer be unable to attend within 14 day a new anti-code will be required,
Service Required this again can be provided by your service engineer.
Quote # 3456

Chapter 4.8

www.PDF-Zoo.com
Detection Systems Abacus User Guide

Testing and Reading the Log Flow Chart

Unset (Day Mode)

Enter User Code

1=Prog 2=Test
Set System ? NO* Omit Zone ? NO 3=Log 4=Day(Quit)
(See Chapter 2) (See Chapter 2) 1 2 3
(See Chapter 3)

1=Zone 2=Bell
4=Active
1 2 4

Test 1=Bell 2=LS 1 A < INACTIVE > B


3=LS 2 4=LS 3 2 5 7 12345678
O/ESC 1 2, 3 or 4 O/ESC

Test 1=Part 2=Exit 1=View


3=Entry 4=Alarm 3=List 4=Program
O/ESC x 2 O/ESC x 2 1 3, 4

1=Zone 2=Bell
4=Active

O/ESC

Note Read log to escape Printer prints out as


* Version 7000 software, press 0/ESC requested press
introduced a new menu, in case 0/ESC to stop the
of mistake to allow return to day printing
mode, press the YES/PART key
to continue or No key to return
to day mode. 1=View
3=List 4=Program
O/ESC

1=Prog 2=Test
3=Log 4=Day

At this menu, press the 4 key to return to the Day Mode

Chapter 4.9

www.PDF-Zoo.com

You might also like