Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Apd NG660

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

UL2200

APD-NG660
APD-ULV350 NG/LP

AKSA Power Generation has been producing industrial generator sets with an innovative compact design and
excellence in quality for over 30 years. AKSA has been providing reliable power through three main production plants
and over 15 branch offices worldwide.

General Characteristics

Model Name APD-NG660

Engine Make PSI (Doosan)

Engine Model 32L

Alternator Make Stamford

Control Panel Make & Model DSE 7320

Frequency & Speed 60Hz, 1800rpm

Enclosure Make & Model AKSA AUL 96

Genset Rating

NG NG
Engine Alternator Voltage PF Standby Standby
Power Current

HCI634G (Wnd-311) 208/120V 0.8 657.7kW 2282.1A

HCI634G (Wnd-311) 240/120V 0.8 657.7kW 1977.7A


32L
HCI544F (Wnd-311) 480/277V 0.8 661.9kW 995.2A

*EPA – Certified for Emergency Stationary Applications


Stand-by Power (Maximum): Power available at variable load in the event of main power network failure. No over load is permitted.
Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours of operation.
The above ratings represent the engine performance capabilities to conditions specified in accordance with ISO 8528/5 & ISO3046.
Derating may be required for conditions outside of the test conditions.

Codes & Standards

The Generator set is designed and manufactured in a facility certified to ISO9001 standards.

The Generator set is designed and manufactured in a facility certified to ISO14001:2015 standards.

AKSA Power Generation provides single source responsibility for the generator set & accessories.

The generator set, with its components, are prototype tested and production tested according to the UL test program.

The generator set meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per
NFPA standards.

*Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

www.aksausa.com www.aksausa.com
www.aksalatam.com
UL2200
APD-NG660 NG/LP

Engine Data Electric System

Manufacturer PSI System Voltage (dc) 24V

Model 32L Battery Qty, Rating 2 x 143Ah

Displacement & Cylinders 31.8 L / 12 Cylinders


Cooling System
Engine Type V-type, 4 Cycle
Radiator Cooling System Type Closed Circuit
Engine Speed 1800rpm
Coolant Capacity 54 gal
Engine Standby Power NG 720kWm
Cranking Temperature 176˚F
Engine Standby Power LP 475kW
Full Open Temperature 198 ˚F
Aspiration Turbo Charge Air Cooled

Compression Ratio 10.5 : 1


Exhaust System

Type Water cooled manifold


Bore / Stroke 150 mm / 150 mm

Max. allowable back pressure 10.2 kPa


Governor type Electronic

Turbine Outlet Temperature 1138 ˚F / 683 ˚C

Fuel System Exhaust Gas Flow at Rated


3844 cfm
Power
Fuel Type NG, LP Gas/Dual Fuel

Air Intake System


NG Supply pipe size 3.0” NPTF

Combustion Air Required 1320 cfm


Maximum EPR Rated Pressure 6.9kPa

Recommended Max Pressure 2.7 kPA / 11.0 inH2O Max Intake Air Restriction
1.24 kPa / 5inH2O
(Clean Element)

Recommended Min Pressure 1.7 kPA / 7.0 inH2O


Air Filter Type Dry Paper Element

Lubrication System
Fuel Consumption
SAE 15W-40 Low Ash Gas
Natural Gas LP Gas Oil Specifications Engine oil, API CD/CF or
higher
292 lb/h 300 lb/h
Standby Power (100%)
133 kg/h 136 kg/h
Oil Capacity, Min-Max 95 – 129 Qts
225 lb/h 222 lb/h
Standby Power (75%)
102 kg/h 101 kg/h
Oil filter; qt, type 2, Cartridge
164 lb/h 153 lb/h
Standby Power (50%)
74 kg/h 69 kg/h
Min – Max Oil Pressure at Rated 47psi – 57 psi
Speed 3,24 bar – 3,93 bar

*Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

www.aksausa.com
UL2200
APD-NG660 NG/LP

Alternator Data Controller Data

Manufacturer Stamford Manufacturer DSE

Standards BS EN 60034 Model 7320 MK II

Control System PMG


Controller Features & Benefits
A.V.R. MX321
Microprocessor controlled, UL & NFPA110 Compatible

Voltage Regulation ± 0.5 % License free PC Software (Non-proprietary Software)

IP65 rating offers increased resistance to water ingress


Insulation System Class H
Modules can be integrated to building management systems
Protection IP23
Real time clock provides accurate event log

Rated Power Factor 0.8 Four line back-lit LCD text display

Five key menu navigation, two wire start/stop at Auto mode


Stator Winding Double Layer Lap
Front panel editing with PIN protection
Winding Pitch Two Thirds
Support up to three remote display modules
Winding Leads 12 Configurable timers and alarms

Telephone Interference THF < 2 % Multiple date and timer scheduler

Integral PLC editor


Waveform Distortion 0.5 < No Load < 1.5 %
‘Protections disabled’ feature
Maximum Over speed 2250 rev/min
Load switching (load shedding and dummy load outputs)

Fully configurable via DSE Configuration Suite PC Software


Battery Charger & Electrical System Data
SCADA monitoring via DSE Configuration Suite PC Software
Manufacturer ComAp
Protection Instruments
Model InteliCharger
✓ Gen. Voltage – under / over ✓ Gen. Voltage (L-L/L-N)

Input Voltage 90V ~ 277V AC ✓ Gen. Freq. – under / over ✓ Gen. Frequency

✓ Engine Speed – under / over ✓ Engine speed


Output Voltage / Current 24V Float / 3A pk
✓ Engine Oil Pressure – low ✓ Oil Pressure

Jacket Water Heater Data ✓ Engine Temp – low / high ✓ Water Temperature

✓ Battery Voltage – low / high ✓ Battery Voltage


Manufacturer Hotstart
✓ Weak Battery ✓ Run Time

Model CKM1060260-000 ✓ Fail to Start / Stop ✓ Phase Sequence


✓ Power monitoring
✓ Charge Alternator Fail
Input Voltage 240V (kWh/kVAh/kVArh)
✓ Over Current & Load ✓ Power
(kW/kVAr) (kWh/kVAh/kVArh)
Power 6000W
✓ Unbalanced Load ✓ Power Factor

✓ Independent Earth Fault ✓ Generator Current

✓ Reverse Power ✓ Generator Load (%)

✓ Loss of Speed Signal ✓ Earth Current

*Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

www.aksausa.com
UL2200
APD-NG660 NG/LP

Enclosure Features Enclosure Features

✓ Heavy Duty Steel / Aluminum Structure ✓ Internally Mounted Exhaust System with Rain Cap

✓ E-Stop on Enclosure ✓ Coolant Fill Cap

✓ Control Panel Eliminated from Engine Vibrations ✓ Removable Base Frame Lifting Hooks

✓ Standard Sound Attenuation Foam ✓ Oil & Coolant Drain Ports

✓ Plastic Covered Corrosion Resistant Locks & Hinges ✓ Easy Access for Maintenance

Enclosed Gen-Set Dimensions – Level 1

Length 256.1 in

Width w/o lift hooks 91.61 in

Height w/o Silencer 99.02 in

Height with Silencer 129.3 in

Dry Weight 22300 lb

*Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

www.aksausa.com www.aksausa.com
UL2200
APD-NG660 NG/LP

Standard Features & Accessories Optional Accessories

✓ UL2200 Certification ❑ Main Line CB (3 / 4 Poles – 80% / 100% rated)

✓ Heavy Duty Steel Base Frame ❑ Upsize Alternator

✓ PMG ❑ Anti-condensation Heater

✓ Engine Jacket Water Heater ❑ Voltage Regulation ±0.5% w/MX321 AVR

✓ Battery and Battery Rack ❑ Gas Regulator

✓ Battery Charger
❑ NG / LP Auto Changeover Control System

✓ Anti Vibration Pads between Engine/Alternator & Base Frame


❑ Low Gas Pressure Alarm
✓ Roof-mounted Critical Grade Silencer
❑ Low Coolant Level Alarm
✓ Residential Grade Silencer Set for Open Skid Sets
❑ Oil Pan Heater
✓ Exhaust outlet rain cap and radiator fill cap
❑ Oil Temperature Display on Controller
✓ Sound Absorb Foam Material for Enclosure
❑ Manual Speed Adjust Rheostat
✓ Emergency Stop Button
❑ Manual Voltage Adjust Rheostat
✓ Oil Drain Valve
❑ Remote Annunciator Panel
✓ Coolant Drain Valve
❑ Remote Control & Monitoring Panel
✓ Jacket Water Heater Isolation Valves
❑ Advanced SMS Messaging
✓ Flex Fuel Lines
❑ Control Panel Heater
✓ Secondary Lock-off Valve on Baseframe
❑ Battery Disconnect Switch
✓ Engine Manifold Cover
❑ Battery Heater
✓ Turbocharger Cover

❑ Battery Charger 10/20 Amp


✓ Protection Covers for Rotating Parts

❑ Shunt Trip / Aux Contacts


✓ Exhaust Insulation Cover

✓ Enclosure DC Light ❑ Spring Anti-vibration Isolators

✓ Operations Manual ❑ Automatic Transfer Panel (ATS)

✓ 24 Months / 2000 hours Limited Standby Warranty ❑ 5 Years / 2000 hours Limited Comprehensive Warranty

AKSA POWER GENERATION USA LLC DISTRIBUTED BY:


371 Exchange Street, West Monroe,
Louisiana, 71292
Tel: 318.855.8377 Fax: 318.855.8381
E-mail: sales@aksausa.com
AKSA Power Generation USA is a member of

**Manufacturer
Manufacturer reserves
reserves the
the right
right to
to make
make changes
changes in
in model,
model, technical
technical specifications,
specifications, color,
color, equipment
equipment and
and accessories
accessories without
without prior
prior notice.
notice.

www.aksausa.com